Intesis LinxBoxEIB User Manual r0 eng

image

Contents

1. 4 1 Marcona POC E aaner E a E Ra 7 4 2 Managing project folders s sssssssssrssrsrrsrrrnrsrrrrrrnrenrrnrrnnrnrrnnenrrnrrnnrnnrnrrnrrnnne 7 4 3 New 7 Edit Project WINGO Wy sisrsisorinirisrrisn are reinu innr AITEN 8 A4 Project folder c ontents oinisiiieniibiiiaibinaibiia iaia a iioi i a aiaa a 8 5 Navigation Menu button Bar and COMMON window buttons ccceeeeeeeeeeeeeeeeeeeeees 9 5 1 PEU ar S E E neat seueebeesusene 9 Die PUTEO Bole ccuse car auntesisamsien A aides arene tauntennta 9 Bd Common DUELONS vane cccccangunssnauuaacsnecessad eins susie aaeatecesssauausareetatsaameesieasnatgunaaces 10 6 Communication with INteSiISBOX cccccceeeeeeseeeceeeeennneneeeeeeeeeeeeeeeaneaanaanteeeeesnees 11 6 1 COMMECUING to INTESISBOX nassir ci nacetacitnoneobccetasstaneteckbacntee 11 6 2 iges ee OK 5 GUUS ude ccoe suena cee ta T E S E A E 12 63 Signals VICWED ge nccuanagan atv iain auewgoeedubriaesiearin eveseneseneuanasannsipadeneeepeeeeteavermcuwenaeas 13 6 4 DUS MORMOMNG wictenctvutarudienctracseusuruisrneurmetreserudsteeurncteuserueteacuretsasareecurncgrecien 14 6 5 System COMMANAS 2 cece cccccccc cece cece eee eee ee Re DDE EERE EEE EEE E ESSERE SESE EERE EEE EEE 15 7 Project coniiguUratiO soriire mnno a aa na a aa a a a nian 16 AL COONAN WINTON eeren E N EE EE E E 16 7 1 1 Configuration window Useful tiPS cccceecee cece eee e cesses eee eee ee sense eeeeeeeeees 16 7 2 CSV based bulk point CONFIQUIATION cece
2. Dimming 4 bit 1 Switching 1 bit 7 Drive Control 1 bit 2 Dimming 4 bit 5 Float 16 bit 8 Priority 2 bit 2 Dimming 4 bit 17171 Hit Float 16 bit f Float 16 bit 9 Float IEEE 32 bit Float ll 6 bit 10 Counter 16 bit PE i come c2ve Float 16 bit 12 Access 32 bit Float 16 bit 13 ASCI char 8 bit 14 Counter 8 bit 15 String 14 bytes 2 Dimming 4 bit 17172 2 Dimming 4 bit 17173 2 Dimming 4 bit 17174 2 Dimming 4 bit 17175 2 Dimming 4 bit 17176 5 Float 16 bit VF 5 Float 16 bit 17178 mn cm cm cm im on Figure 7 3 Multiple value selection Autoenumeration In some cells such as ID addresses etc the values can be either modified one by one see edit text above or auto enumerated To do so follow the steps below 1 Select using the left mouse button clicking and dragging the field of all the rows in the list which you want to automatically assign values must be consecutive rows 2 Click right mouse button over the selected fields and select Auto Enumeration option from the pop up menu that will appear Intesis Software S L All rights reserved URL http www intesis com 17 20 B This information is subject to change without notice n tes i S E Email info intesis com software IntesisBox is a registered trademark of Intesis Software SL tel 34 938047134 LinkBoxEIB User s Manua
3. LinkBoxEIB User s Manual r0 eng 6 5 System commands System commands should not be used unless advised from Intesis Software technical staff as the use of some of the commands explained can be critical for IntesisBox operation LinkBoxEIB includes an option to send to IntesisBox a set of system commands for debugging and control purposes this list is available in the commands list placed in the Communication console as shown in the figure below The Software needs to be connected to the IntesisBox section 6 to use this commands To send a command to IntesisBox just select it from the list or type it with the correct format and press Enter or click on button Arrow enter button next to the combobox IntesisBox will act accordingly with the command received the process can be monitored in the IntesisBox Communication Console window Ea LinkBoxEIB V 1 1 0 File Options Windows l p pee Pa a a a a a a a a a FIFFI i P gt Pn and ohooh T Ti Bel bed Eo BL bed Ead pa Eoia Cad Coi Pa Copag Col Eui _ ate a ain a tttt TAT BUS DATA EUS DATA Config Connect COM Status Send Reset Signals KNX Modbus_ IntesisBox Communication Console COM7 INFO all ny Iw Active iw AutoS croll Log to file INFO TIME 7 l TIME YYYY MMDD HH NM pTCP B_V 41 0 1_SN1093P111 OFCHANGES 2008711705 Intesis Sottware SL ON CHANGES 0 1 2009 06 22 DEBUG 0 DERLIG 1 D EIB BUS Ok DEBUG 2 pk 255 255_255 0
4. Modbus TCP Accept Cancel Figure 4 2 New Edit project window e Project Name of the project This name is defining the folder where all the configuration files section 4 4 are stored e Description Optional field Useful to save further information about the project e IntesisBox External Protocol of the IntesisBox Check the user Manual of the IntesisBox to integrate to decide which of the protocols need to be selected It can only be edited when a new Project is created 4 4 Project folder contents In any project folder section 4 1 for location you will find following files e Project ini ASCII file containing descriptive information about your project e External Protocol ini ASCII file containing generic configuration of the project e External Protocol dat ASCII file containing the configuration of the project signals It is the one to be used for bulk point configuration section 7 2 e External Protocol L BOX Binary file created from the information in the files described above This is the file really uploaded to IntesisBox It is reasonable that once you get a working configuration for a certain installation you perform a backup of these files their folder from your hard drive Intesis Software S L All rights reserved URL http www intesis com 8 20 B This information is subject to change without notice Nn te amp S i S E Email info intesis com software tel IntesisBox is a regis
5. get updated values After pressing Refresh all signal values will keep continuously updated until the connection is closed i kaj B 55 Signals description name Dev Cod Ident Signal EIS Group Listening adc A W T U Value 1 0 2 D 1 5 0 Add 0 Communication Error 1 Switching 1 bit 1 10 3 0 1 5 1 16 bits sig C2 ModBus gt EN only 5 Float 16 bit Wi 4 D 1 5 1 16 bits sig C2 ModBus KH only Response to RNG 5 Float 16 bit 17172 FY D 1 5 1 16 bits sig C2 ModBus lt gt ENS both directions 5 Float 16 bit Ws By D 1 5 1 16 bits sig Ce Modbus lt gt ENS both directions Resp 5 Float 16 bit 17174 7 0 1 5 1 16 bits sig C2 ModBus gt KMS only 5 Float 16 bit 1717 5 a D 1 5 1 16 bits sig C2 ModBus EH only Response to KN 5 Float 16 bit 1 176 9 0 1 5 1 16 bits sig C2 ModBus lt KEH only 5 Float 16 bit wii 10 0 1 5 1 16 bits sig C2 ModBus lt EN only Update from KM 5 Float 16 bit 17175 Figure 6 5 Signal viewer In order to force a specific value to a signal double click its Value field This will display a dialog in which the desired value can be entered This change will be transferred to the internal and External Protocol depending on their configurations more information in the signals configuration of the User Manual of the Used IntesisBox The signals viewer window has the button to copy to the Windows Clipboard all the contents of the window in t
6. 401 Massys DSC PC4401 For models DSC PC4020 Demo FC3304 E Demo LGE LGE 3 Demo KNX E Demo LON LON 2011 08 08 12 38 38 cy Demo LON E Demo LON Daikin LON Gateway Daikin DM5504851 64 u a amp Demo LON Daikin amp Demo LON LG LON BNU L W LG LonWorks gateway BQ Demo LON Mitsubishi Electr E Demo LON Mitsubishi Electric LON Gateway L MAP a Demo Mitsubishi Electric a Demo LON Mitsubishi Heavy LON Gateway Mitsubishi Heavy SC LG E9 Demo SIA E Demo LON Samsung LON Gateway LON Samsung MIM B07 E Demo ZitonZP3 E Demo LON Sanyo YRF LON Serie PAC Up to 16 groups E Demo LON Toshiba 1 LON Inv map Toshiba TCB IFLN640TL a Demo LON Toshiba 2 LON unit map Toshiba TCB IFLN6407T E Demo Mitsubishi Electric MitsubishiG 50 Gateway Mitsubishi Electric G50 or Ea Demo ModBus Modbus ModBus ATU Demo Modbus TEP f Modbus tee P 2011 08 08 1534 33 Demo Samsung AC Samsung R5485 MIM B134 6044 4 mW b Figure 4 1 Project selection window The window has two differentiated sections On the left side the Project folders explorer and on the right the projects area were the projects located in the selected folder are shown After installation LinkBoxEIB contains the following Project folders e Demo Projects where a demo sample configuration project for each of the existing IntesisBox KNX products can be found These projects should be used only as the base for new ones but not to modify them as when LinkBoxEIB is updated they are over
7. Gw gt Devil IP 192 1608 100 77 Port 502 lt INFO gt IntesisBox EIB MODBUS TCP B V 41 0 1 SN4093P111 sInternal EIB V 1 2 1 2008 11 05 Intesis Software SL Protocol MODBUS TCP 1 0 1 2009 06 22 lt ON CHANGES gt Prhysical Add 15 15 250 EIB BUS Ok gt I B11927 168 100 246 Mask 255 255_ 255_ 0 Gwe Devil IP 192 1608 100_ 77 Port 502 TNHFO Figure 6 7 System commands Brief explanation of some of the commands e INFO gets the information from the IntesisBox e DEBUG Configures the debug level amount of messages showed in the console window Possible values 0 to 3 being O the most restrictive value e RESET resets the IntesisBox as it had lost its power supply e ONCHANGES The changes in the IntesisBox are going to be sent to the console window e OFCHANGES The changes in the IntesisBox are not going to be sent to the console window Intesis Software S L All rights reserved URL http www intesis com 15 20 B This information is subject to change without notice Nn tes i S E Email info intesis com software IntesisBox is a registered trademark of Intesis Software SL tel 34 938047134 LinkBoxEIB User s Manual r0 eng 7 Project configuration To configure the integration connection parameters and the points list click on Config in the Button Bar Figure 7 1 The External Protocol Configuration window will be opened For integrations with a large number of points an alternative CSV based c
8. LinkBoxEIB Configuration amp monitoring software of IntesisBox KNX series User s manual Issue Date 2011 08 08 rO eng software LinkBoxEIB User s Manual r0 eng Intesis Software S L All Rights Reserved Information in this document is subject to change without notice The software described in this document is furnished under a license agreement or nondisclosure agreement The software may be used only in accordance with the terms of those agreements No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or any means electronic or mechanical including photocopying and recording for any purpose other than the purchaser s personal use without the written permission of Intesis Software S L Intesis Software S L Mila i Fontanals 1 bis 1 08700 Igualada Spain TRADEMARKS All trademarks and tradenames used in this document are acknowledged to be the copyright of their respective holders Intesis Software S L All rights reserved URL http www intesis com 2 20 B This information is subject to change without notice Nn te amp S i S E Email info intesis com software tel IntesisBox is a registered trademark of Intesis Software SL oae 34 938047134 LinkBoxEIB User s Manual r0 eng INDEX 1 TIVEPOG Esu e a P E E E E 4 2 M EON a a E A E E E a rama waned 4 3 Pils GX CCU a E E E E E E T A A T A E E E E E ETE 4 4 Project Manage erpen E a EATE 6
9. ab separated text format Intesis Software S L All rights reserved URL http www intesis com 13 20 B This information is subject to change without notice Nn tes i S E Email info intesis com software IntesisBox is a registered trademark of Intesis Software SL tel 34 938047134 LinkKBoxEIB User s Manual r0 eng 6 4 Bus monitoring To monitor any of the buses the software needs to be connected to the device section 6 1 To do so click on the KNX and External Protocol buttons and the bus viewers are going to be opened showing the frames transmitted or received Figure 6 5 E LinkBoxEIB V 1 1 0 File Options Windows J UA Za O02 E 5 X tttt ALLAL LIVE DATA BUS DATA BUS DATA Projects Config Connect COM7 Status Send Receive Reset Signals KNX Modbus_ NX Internal Protocol Communication Viewer oles 8 Modbus_TCP External Protocol Communication Viewer Active MV AutoScroll l Log to file IV Active MV AutoScroll l Log to file 00 00 00 80 00 00 zd i ci T s2 si p tL I h A yi 22 l s4 4 zd i si I r p ot z4 P Figure 6 6 External Protocol and KNX Bus Viewer Intesis Software S L All rights reserved URL http www intesis com 14 20 e This information is subject to change without notice n tes i S E Email info intesis com tel IntesisBox is a registered trademark of Intesis Software SL eonen 34 938047134
10. alog registers ae 1 3 Aead ie eS Pe d write 1 3 Read analog registers 2 Read digital inputs d write 1 3 Read analog registers 3 Read analog registers 1 3 Read analog registers d write 1 3 Read analog registers 4 Read analog inputs d write 1 4 Read analog inputs 5 Write 1 digital output 1 4 Read analog Inputs 6 Write 1 analog register 1 4 Read analog inputs 1 2 Read digital inputs 15 Write multiple digital output 1 2 Read digital inputs 16 Write multiple analog registers d_write 1 2 Read digital inputs T e Write 1 3 Aead analog registers 11 16 bits digitala 1 O OU BI_10 Figure 7 2 Select value Multiple Values selection 1 Select using the left mouse button clicking and dragging the field of all the rows in the list which you want to change the values must be consecutive rows 2 Right click in the cell 3 A contextual menu with the possible values will show up Figure 7 3 4 Select the desired value 5 All the selected cells are going to be changed to the chosen value y 1 Switching 1 bit EIS Group 1 Switching 1 bit 2 Dimming 4 bit 1 Switching 1 bit 1 170 1 Switching 1 bit SN eg ee 1 Switching 7 bit 1S uitehing 1 bit a EE sola e Bimmng la i 3 1 Switching 1 bit 4 Date 24 bit 2 Dimming 4 bit 1 Switching 7 bit 5 Float 16 bit 2 Dimming 4 bit 1 Switching 1 bit pws A 2 Dimming 4 bit 1 Switching 1 bit e lel i 2
11. ation is subject to change without notice Nn te amp S i S E Email info intesis com software tel IntesisBox is a registered trademark of Intesis Software SL oae 34 938047134
12. ation projects That includes setting the linked signals protocol parameters When the LinkBoxEIB is connected to the IntesisBox it can perform other functionalities such as monitoring the communication and sending the configuration files to the device section 8 The steps to follow are 1 On the Button bar click on COM1 IP Figure 5 1 2 Select the connection method Figure 6 1 from Serial port or IP and configure their parameters Once finished click on Save If when using IP connection the IP of the IntesisBox is not known follow instructions in point 3 ahr IntesisBox connection t Seral Port CoM 1 57600 te IF 192 168 100 100 IP 23 Port Cancel Figure 6 1 Connection window 3 only for IP connection If the IP is not known click on the arrow next to the IP button Figure 6 2 and then on SEARCH DEVICES That will find the IntesisBox connected to the user s subnet The information of the connected gateways is displayed in the Communication Console Figure 6 3 E LinkBoxEIB V 1 1 0 File Options Windows ITA Projects Config Connect IP Signals KNX Modbus_ Z IntesisBox Communication SEARCH DEVICES Figure 6 2 Search IntesisBox when connected to the Ethernet A Important If there is no project loaded in the IntesisBox i e if the cable was disconnected while sending the configuration file the IP Parameters of the gateway are going to be IP 192 168 100 246 and UDP port 23 In
13. ed URL http www intesis com 9 20 B This information is subject to change without notice Nn tes i S E Email info intesis com software IntesisBox is a registered trademark of Intesis Software SL tel 34 938047134 LinkBoxEIB User s Manual r0 eng 5 3 Common buttons wi Clear log Deletes all the traces in the window ET Copy to Clipboard When ticked the log is enabled W AutoScrall When ticked scroll follows the last line of the log Logtofile When ticked the log is saved in the project folder Table 5 1 Common button description Intesis Software S L All rights reserved URL http www intesis com 10 20 B This information is subject to change without notice Nn tes i S E Email info intesis com software IntesisBox is a registered trademark of Intesis Software SL tel 34 938047134 LinkBoxEIB User s Manual r0 eng 6 Communication with IntesisBox In this section it is detailed how to set the communication and monitor the IntesisBox 6 1 Connecting to IntesisBox There are two different ways of communicating the LinkBoxEIB with the IntesisBox check the Connection section in your IntesisBox User Manual using the serial port or the Ethernet network using UDP In the following lines the configuration of both is explained as well as the functionalities of LinkBoxEIB when connected or not When there is no connection with the IntesisBox LinkKBoxEIB allows the creation and edition of configur
14. eee eee ee eee eee e eee e eee e eee e eee e eens 19 8 Sending the configuration to the INteSISBOX ccceeeeeeeeeeeeeeeeeeeeeeeeueuuueueuauauanags 20 Intesis Software S L All rights reserved URL http www intesis com 3 20 B This information is subject to change without notice Nn te amp S i S E Email info intesis com tel IntesisBox is a registered trademark of Intesis Software SL mae 34 938047134 LinkBoxEIB User s Manual r0 eng 1 Introduction LinkKBoxEIB is a Windows compatible software tool developed specifically to monitor and configure the IntesisBox KNX series IntesisBox KNX EIB integrating an External Protocol In this document its use and how to configure the IntesisBox is explained In the document the following nomenclatures are used e External Protocol Protocol that the used IntesisBox integrates besides KNX i e if using the IBOX KNX MBTCP MBTCP Modbus TCP would be the External Protocol e External Protocol To know the file name replace External Protocol with the External Protocol name e IntesisBox or gateway the words gateway or IntesisBox are used instead of the full product name IntesisBox KNX EIB integrating an External Protoco Any other use of the word gateway not meaning that will be specifically indicated 2 Installation Periodically new free versions of LinkKBoxEIB are released including improvements fixes Support for new firmware versions of IntesisBo
15. epad 5 Paste it to your spreadsheet 6 Modify the data 7 Copy all the data from your spreadsheet 8 Paste it to your Notepad file 9 Save the file 10 Open the project in LinkBoxEIB section 4 and check the modifications in the signal list tab Intesis Software S L All rights reserved URL http www intesis com 19 20 B This information is subject to change without notice Nn tes i S E Email info intesis com software IntesisBox is a registered trademark of Intesis Software SL tel 34 938047134 LinkBoxEIB User s Manual r0 eng 8 Sending the configuration to the IntesisBox When the configuration of the project is finished and once its window it is been closed follow the following steps 1 Click on the Send button placed in the button bar section 5 2 Click Accept when asked 3 Check the Communication console The information about the device should appear once it is programmed If an error is shown check that the LBOX file was correctly generated and that all the steps explained in the previous sections have been followed 4 IntesisBox will reboot automatically once the new configuration is loaded 5 If using the IP connection the LinkBoxEIB needs to be reconnected to the IntesisBox once it is rebooted The configuration cannot be received from the gateway to LinkBoxEIB it can only be sent Intesis Software S L All rights reserved URL http www intesis com 20 20 B This inform
16. k its information To do so just click on the icon and the LinkBoxEIB will require the IntesisBox Status The possible values of the status Icon are eo The IntesisBox is OK Problem in the IntesisBox The most probable situation is that the last time the configuration was send to the IntesisBox the process didn t end c Unknown status of the IntesisBox as the LinkBoxEIB is not getting an answer E when enquires Intesis Software S L All rights reserved URL http www intesis com 12 20 B This information is subject to change without notice n tes i S E Email info intesis com software IntesisBox is a registered trademark of Intesis Software SL tel 34 938047134 LinkBoxEIB User s Manual r0 eng 6 3 Signals viewer To supervise the configured signals either being connected to the IntesisBox or not click on the Signals button in the Button Bar This will open Signals Viewer window This window shows all active signals within the gateway with its main configuration parameters and its real time value if connected to the IntesisBox in the column Value E LinkBoxEIB V 11 0 File Options Windows ol nii e SSS SS aa eS RS Ke lololo r 7 Oodle O1O01010 ete ST z tttt LIVE DATA BUS DATA Config Connect COM7 Status Send Reset Signals KNX Modbus_ Figure 6 4 Button Bar If you connect to the IntesisBox when it s been running for a certain time you should press the Refresh button gt D to
17. l for bulk point project configuration section 7 2 or for backups of the projects Drag amp drop Projects can be dragged and dropped inside any project folder By default Move Copy they are going to be moved an arrow appears next to the cursor If the project Ctrl Key is pressed they are going to be copied instead a symbol appears next to the cursor 4 2 Managing project folders Actions that can be done in the Project folder area IntesisBox can be selected and modified details in section 4 3 Delete folder Deletes the selected folder Not allowed if Explore folder Opens the folder to explore it Drag amp drop Projects can be dragged and dropped inside any project folder By default Move Copy they are going to be moved an arrow appears next to the cursor If the folder Ctrl Key is pressed they are going to be copied instead a symbol appears next to the cursor Intesis Software S L All rights reserved URL http www intesis com 7 20 E This information is subject to change without notice n te K S E Email info intesis com software tel IntesisBox is a registered trademark of Intesis Software SL 34 938047134 LinkBoxEIB User s Manual r0 eng 4 3 New Edit Project window When a new project is created edited or copied sections 4 1 and 4 2 Figure 4 2 pops up In this section its fields are explained E Froject Project Demo ModBus TCP Description Modbus demo IntesisBox
18. l r0 eng 4 16 bits sig C2 4 16 bits sig C2 o 2 Auto Enumeration 4 176 bits sig C2 4 read write 2 16 bits uns 0 Bl_1_tead 2 16 bits uns 0 BO_1_tead_write 2 16 bits uns 0 BY _1_read_write 4 16 bits sig C2 O Al read 4 1 bits sig c2 oo a 0 AD_2 read 4 16 bits sig c2 9 0 AN 2 read 1 1 bit 0 Bl_2 read Figure 7 4 Autoenumeration selection 3 Enter the first value to assign 5 Auto Enumeration Add fiad Accept Cancel Figure 7 5 Autonumeration first value 4 Enter the increment between consecutive assignments For example selecting 100 for the first value and an increment of 1 the values generated will be 100 101 102 103 104 and so on To assign the same value to all the rows useful to assign the Same Device number in the column Dev for some consecutive rows just select the desired value and an increment of 0 5 Auto Enumeration Enter the increment il Accept Cancel Figure 7 6 Autonumeration increment 5 The values are changed accordingly 4 16 bits sig C2 0 Al 1 read 4 16 bits sig C2 0 AQ 1_tead_write 4 176 bits sig C2 102 OAM ead write 2 16 bits uns 103 0 Bl_1_read 2 16 bits ung 104 0 BO 1 read write 2 16 bits uns O BY_1_tead_write 4 16 bits sig C2 0 Al read 4 16 bits sig C2 107 0 AQ 2 read 4 176 bits sig C2 108 OAM 2 read 1 1 bit 109 O Bl read Figure 7 7 Values autonumerated Intesis Software S L All rights reserved This information is s
19. nd kept in their actual location too Figure 3 2 Move and delete old projects Intesis Software S L All rights reserved URL http www intesis com 5 20 B This information is subject to change without notice n tes i S E Email info intesis com software IntesisBox is a registered trademark of Intesis Software SL tel 34 938047134 LinkBoxEIB User s Manual r0 eng 4 Project manager The tool is based on the concept of configuration projects After starting LinkBoxEIB by clicking its program entry under Windows Start menu or any other established link a project manager window will pop up asking the configuration project to open This window is used to organize create edit and delete the projects explained in the following sections The location of the selected folder can be seen on the top section of the window Gy Projects oo Project Folders IC Intesis LinkBoxEIB ProjectsEIB Demo Projects ProjectsEIB i E Demo Projects a Demo irzone Alrzone 1 CS 5 Zonas ASQ My Projects E Demo ASCII ASCII 3 Old Projects E Demo BACnet Bacnet BACnet IP p g Demo 45Slave E Demo BACnet Daikin 064 Bacnet Gateway Daikin DMS502451 64 AQY Demo AlgorexPin EB Demo BACnet Daikin 256 Bacnet Gateway Daikin DMS502451 DA S Zl ri Hebrew Demo Bacnet LG AC 64lU Bacnet LG PONFB17B0 E S Deria Bacri Ea Demo BACnet Mitsubishi He Bacnet Gateway Mitsubishi Heavy SC BG 3 Demo DEGD E Demo DSC PC4
20. onfiguration method is explained in section 7 2 E LinkBoxEIB V 1 1 0 File Options Windows i Pana ma a a a a a a a a i oOo U So S OOY YO L s ZZ ao F bj LIE DATA A EUS DATA Modbus_ US DAT Projects Config Connect COMI Signals KNX Sy M Active M AutoScroll Logto file Figure 7 1 Menu and Button Bar in LinkKBoxEIB 7 1 Configuration window The configuration window is different for each External Protocol and for that reason it is explained in the User Manual of each IntesisBox 7 1 1 Configuration window Useful tips In the following lines some tips procedures to help configuring the signals of the IntesisBox can be found In which cells can be used it is going to be specified in each user Manual Text Edit Double click on the cell The text is going to be highlighted and it can then be modified Value selection 1 Right click in the cell 2 A contextual menu with the possible values will show up Figure 7 2 Select the desired value Intesis Software S L All rights reserved URL http www intesis com 16 20 B This information is subject to change without notice Nn tes i S E Email info intesis com software IntesisBox is a registered trademark of Intesis Software SL tel 34 938047134 LinkBoxEIB User s Manual r0 eng 3 O Communication Error onomunication Error Dey 4 0 Communication Error 0 Cormmunication Error ation Error Dev 4 1 3 Aead an
21. tered trademark of Intesis Software SL oae 34 938047134 LinkBoxEIB User s Manual r0 eng 5 Navigation Menu button Bar and common window buttons E LinkBoxEIB V 11 0 File Options Windows Zs Projects Config Connect COM E LinkBoxEIB V 11 0 File Options Windows CU 2 BUS DATA BUS DATA Config Connect COM Status Send Reset Signals KNX Modbus_ 233333232 S1Od1910 l li O1OO1d10 DATA BUS DA i BUS i KNX Modbus_ Figure 5 1 Menu and button Bar To work with LinkBoxEIB the menu and the Button Bar Figure 5 1 need to be used In the following lines a brief explanation and links to the corresponding section can be found 5 1 Menu In the menu it can be selected the language Options gt Language arrange or select the windows to see under Windows menu and exit the software 5 2 Button Bar e Projects Opens the Project Manager Section 4 e Config Opens the configuration window Section 7 e Connect COM1 IP amp Status Connection with IntesisBox Section 6 e Send To send the configuration to the IntesisBox section 8 e Receive Not in use e Reset Resets the IntesisBox e Signals Show Hides the signals window section 6 2 e KNX Shows Hides the internal KNX communication viewer section 6 4 e External Protocol name changes depending on the IntesisBox Shows Hides the External Protocol communication viewer section 6 4 Intesis Software S L All rights reserv
22. tesis Software S L All rights reserved URL http www intesis com 11 20 B This information is subject to change without notice n te K i S E Email info intesis com software tel IntesisBox is a registered trademark of Intesis Software SL ii 34 938047134 LinkBoxEIB User s Manual r0 eng 4 Once the communication protocol is been configured click on Connect 5 If the connection has been successful the Connect and Status symbols will turn green and the information of the device will appear in the communication Console Figure 6 3 Otherwise check the connection parameters in previous points connections check the Connection section in your IntesisBox User Manual and the status meaning section 6 2 File Options Windows A 2 6 2 Ls Config Connect COM Status Send Reset Signals KNX Modbus_ IntesisBox Communication Console COMT ra el lw Active W Autoscroll Log to file IntesisBox EIB MODBUS TCP B V 41 0 1 S5N4093P111 gt Internal EIB V 1 2 1 2008 11 05 Intesis Sottware SL gt Protocol MODBUS TCP 1 0 1 2005 06 22 lt ONCHANGES gt Physical Add 15 15 250 EIB BUS Ok gt IP2I192 168 100 246 Mask 255 255 255 0 Gw gt Dew il IP 192 1648 100 77 Port 502 Figure 6 3 Connected To disconnect simply click on the Connect button again 6 2 IntesisBox Status The status Icon has both the function of showing the actual status of the communication with the IntesisBox as well as being used to chec
23. ubject to change without notice IntesisBox is a registered trademark of Intesis Software SL Intesis Email e URL http www intesis com info intesis com 34 938047134 18 20 LinkBoxEIB User s Manual r0 eng 7 2 CSV based bulk point configuration For integrations with a large number of points an alternative CSV based configuration method can be used To do so the file to be used is the DAT file of the project section 4 4 Its structure is the same as the signal tab explained in the User Manual of the IntesisBox and the same restrictions and values apply To access the file use the Project Manager section 4 or do so directly with the Windows explorer Being a tab separated file it can be edited with several programs Just a few indications need to be followed 1 Some of the parameters can be confused with dates by some programs Make sure that doesn t happen by setting the cells format to text before importing the data 2 Respect the file format otherwise when opened from LinkBoxEIB would not be exportable to the IntesisBox a Don t add any columns b Adding rows is allowed 3 Follow the restrictions and use accepted values exposed in section the User Manual of the IntesisBox Suggested modification procedure 1 Open the External Protocol DAT file section 4 4 with notepad 2 Open excel or any other spreadsheet software 3 Select all the cells and set them to text mode 4 Copy all the data from not
24. written e My projects Empty folder to be used to store user projects e Old Projects optional Info in section 3 On the projects area the following information of the existing projects can be found e Project Project name e Protocol External Protocol e Description Description of the project optional e Modified Last date and time that the configuration of this project has been modified Intesis Software S L All rights reserved URL http www intesis com 6 20 B This information is subject to change without notice n tes i S E Email info intesis com software IntesisBox is a registered trademark of Intesis Software SL tel 34 938047134 LinkBoxEIB User s Manual r0 eng e Sent to gateway Last date and time that the configuration of this project has been sent to the IntesisBox 4 1 Managing projects Actions that can be done in the Project area Contextual menu Open project Loads the selected project to LinkBoxEIB New protect Creates a new project The project name description and External Protocol proj IntesisBox can be selected and modified details in section 4 3 New project as Creates a new project from the selected one Only the project name and description can be modified details in section 4 3 Edit project Edits the project name and description details in section 4 3 Delete project Deletes the selected project Explore Opens the folder where all the project files are stored Usefu
25. x or support for newer products of IntesisBox KNX series family of devices Check the link in the installation sheet supplied with the device to ensure that you have latest version of the tool The tool is supplied in the shape of a self extracting setup utility Supported operating systems are Windows XP Windows Vista and Windows 7 3 First execution In version 1 1 0 of LinkBoxEIB the project folder was changed to C Intesis LinkBoxEIB ProjectsEIB From this version of the software during its first execution it checks if there are projects from older versions placed in another location If so the user is prompted about coping of moving these folders Figure 3 1 TinkBoxtle Fh Detected Old Projects Do you want to copy or move these Projects P from old location to the new Project s Folder location v Figure 3 1 Copy or Move old projects Intesis Software S L All rights reserved URL http www intesis com 4 20 B This information is subject to change without notice Nn te amp S i S E Email info intesis com software tel IntesisBox is a registered trademark of Intesis Software SL oona 34 938047134 LinkBoxEIB User s Manual r0 eng If yes is selected the old projects are going to be copied moved to the new location inside the folder O d Project folder Figure 4 1 Right away the user needs to select if the old projects should be moved and deleted Figure 3 2 If no is selected they will be copied a