Home
User`s Manual
Contents
1. Set Model Number Battery Life RTR 505 TC About 10 months RTR 505 Pt About 10 months RTR 505 V About 10 months RTR 505 mA About 10 months RTR 505 P About 10 months The battery warning mark may appear sooner than noted above Battery life will be shortened when downloading data very often setting the record ing interval at less than ten seconds or measuring in an environment below 20 C 4 F or above 60 C 140 F Notes about Changing the Battery Before replacing a battery please make sure to download any necessary data and proceed with changing the battery If plus and minus are mistaken or if the battery terminals and are shorted the recorded data that is stored in the Unit will be lost Downloading of data cannot occur while the battery is removed Example of Display Display varies depending upon the model being used RTR 505 TC Thermocouple G3 Ermer Cc Temperature measurement Unit F C will be displayed Sensor type will be displayed under the measurement the factory default setting is Type K By using the software included with the Base Unit you can change the sensor type RTR 505 Pt Pt100 Pt1000 ae CMe ri A h oe ee Pt Temperature measurement Unit F C will be displayed Sensor type will be displayed under the measurement the factory default setting is Pt100 By using the software included with t
2. Communication nterfaces Wireless Communication Optical Communication Wireless Communication Specifications RF Power SmW Radio Standard Specifications ETSI EN 300 220 Frequency Range 869 7 to 870MHz Transmission Range About 150 meters 500 ft if direct and unobstructed Communication Speed About 2 min when downloading 1 unit at full logging capacity Optical Communication Speed About 160 sec when downloading 1 unit at full logging capacity at 2400bps Power Lithium Battery LS14250 Lithium Battery CR2 3 Battery Life 4 About 10 months for temperature measurement Waterproof Capacity Splash proof rated for use in daily life 5 Dimensions H62xW47xD19mm excluding protrusions and sensor Weight About 56g including battery excluding Input Module Operating Environment Operating Temperature Range 30 to 80 C The operating temperature range and measurement range is 40 to 80 C but wireless communication cannot occur in an environment of less than 30 C Other A Base Unit is required sold separately Compatible Base Units RTR 500NW RTR 500AW RTR 500 RTR 500DC 1 Measurement items other than Pulse will have different measurement range depending on the Input Module and sensor to be connected For details see the User s Manual included with the Input Module 2 When using RTR 500NW or RTR 500AW as a Base Unit
3. Wireless Data Recorder RTR 505 User s Manual Thank you for purchasing our product Carefully read this instruction manual before using this Unit CE Outline of RTR 505 Part Names External Input Module Type Splash proof rated for use in daily life RTR 505 is a Data Logger designed to measure and record different items depending on the Input Module to be connected temperature Thermocouple Pt voltage 4 20mA and pulse The body is splash proof rated for use in daily life which can be placed in an environment between 40 and 80 C Recorded data can be automatically collected from the RTR 505 via wireless communication with the Base Unit sold separately and Optical also viewed in graph and table form as well as printed Communication out by using the supplied software Area Antenna LCD Display Package Contents Data Logger RTR 505 Tubed Lithium Battery LS14250 Input Module Strap User s Manual this manual including warranty An Input Module included in the package differs depending upon which set model has been purchased 7 Sensor Jack RTR 505 is a Remote Unit In order to use wireless communication it is necessary to purchase a Base Unit separately Compatible Base Units RTR 500NW RTR 500AW RTR 500 RTR 500DC Wireless Data Recorder RTR 505 is referred to as the Unit in this manual T amp D Corporation http www tandd
4. it may cause burns or frostbite A CAUTION This Unit has been designed for private and or industrial use only It is not for use in situations where strict precautions are necessary such as in connection with medical equipment where directly or indirectly Harmful gases or chemicals may cause corrosion and or other danger to the Unit Also by coming in contact with hazardous substances harm may occur to the people handling the Unit Therefore do not use or store the Unit in any environment that is exposed to chemicals and harmful gases Battery life varies depending upon measuring environment frequency of communication Unit settings and battery performance When using the Unit in a low temperature environment below 20 C the battery power will be depleted more quickly than when using under normal temperature conditions Battery terminals may provide insufficient contact due to age or vibration This may lead to data loss The Unit becomes splash proof rated for use in daily life only after the Input Module has been connected A Compliance Information CE Statement This device complies with technical specifications required under EN 301 489 with battery and AC Adaptor EN 300 220 and EN 60950 1 CE A Important Notice Wireless products cannot be used in countries other than where those products have been approved for use according to that country s wireless regulations T amp D Corpor
5. BPE IP of 9902 Do not use or store the Unit in places such as listed below It may result in malfunction or unexpected accidents Areas exposed to direct sunlight Areas exposed in water or high pressure water flow Areas exposed to organic solvents and corrosive gas Areas exposed to strong magnetic fields Areas exposed to static electricity Areas near fire or exposed to excessive heat Areas exposed to excessive dust dirt and smoke Contact with oil may cause cracks to appear in the casing of the Unit When using this Unit in environments where such oils are present please insure that it is protected from contact through use of a polyethylene bag or other means A Notices about using the Input Modules When making Adjustment Settings in the Adjustment Tools application the adjustment values will be saved to the Input Module Therefore when an Input Module is replaced it is necessary to re make any desired adjustment settings to be written into the newly connected module Wireless Data Recorder RTR 505 Warranty Guarantee Period 1 year from date of purchase Date of Purchase Customer s name Address Phone No Distributor s name Address Phone No Object of Repair Main Unit excluding sensors and any other options Method of Repair Send in for Repair Provisions for Free Repair 1 If the Unit does not work properly despite the fact that the customer used it properly and in line wi
6. When Recording Mode has been set to One Time and the Unit reaches its logging capacity of 16 000 readings recording will automatically stop and in the LCD the mea surement and the word FULL will alternately appear GEJ ONETIME papoo Lik Lm Estimation of time until FULL is displayed pocni 1 second 30 seconds 1 minutes 10 minutes 60 minutes Interval Period About 4 hours About 5 days About 11 days About 111 days About year and 10 months Data Transmission via Wireless Communication c The measurement and the word SEnd will alternately Z m d appear when data is being sent via wireless communi K cation to the Base Unit Recording will continue during wireless transmission _ If this appears all data that was stored in the Unit will 4 H E L have been erased This message will appear under the following conditions The first time a battery was inserted after purchase When the battery is replaced after having been taken out for a long period When the battery is replaced after the battery power has been lost Input Module Unrecognized factory default This will appear if after purchasing the Input Module has never been connected to the Unit No unit for display Note that a RTR 505 P has been set to measure Pulse by default therefore the unit P will be displayed Input Module Unconnected or Damaged
7. com 817 1 Shimadachi Matsumoto Nagano 390 0852 JAPAN Fax 81 263 40 3152 Copyright T amp D Corporation All rights reserved This is printed using recycled paper 2011 09 16504760004 1st Edition 1 Installing the Battery 1 Remove the screws and open the cover Make sure to use the proper size and type of screwdriver Phillips head 1 screwdriver is recommended 2 Insert the included battery Do not remove the battery from its tube casing If using a CR2 lithium battery the tube is not necessary 3 Check the rubber packing for any cuts or scratches and close the cover as it was when Screws opened ing if it is damaged Rubber Packing inserted into tube Be sure to completely close the cover Make sure not to over tighten the screws Appropriate Tightening Torque 20N cm to 30N cm 2Kgf cm to 3Kgf cm Specifications Device Name RTR 505 Measurement Items 1 Temperature Voltage 4 20mA Pulse Recording Intervals Select from 15 choices 1 2 5 10 15 20 and 30 sec 1 2 5 10 15 20 30 and 60 min Logging Capacity 16 000 Readings Recording Mode 2 Endless One Time Factory Default Setting Endless LCD Displayed Items Measurement Recording Status Recording Mode Battery Life Warning Unit of Measurement Full Logging Capacity FULL Sensor Unconnected Input Module Unconnected Measurement Range Exceeded Display Range Exceeded
8. for any malfunction or trouble caused by the use of our product or by any problem caused by the use of measurement results of our unit Please be fully aware of this before using our product This manual cannot be reissued so please keep it in a safe place Please read the warranty and provisions for free repair carefully afety Precautions and Instructions Please carefully observe the following safety measures when using our product To prevent any loss or damage to our customers other people and or property and to ensure the proper use of our products we ask that before using our product you carefully read understand and follow the safety rules and precautions for our products as outlined below A DANGER Do not take apart repair or modify the Unit It may result in malfunction or unexpected accidents Do not use any other batteries than those that are specified in this manual It may cause fire or malfunction If water or a foreign object enters the case immediately remove the battery and cease using it It may result in malfunction or unexpected accidents Store the Unit and accessories out of the reach of children Not doing so may cause an unexpected accident If any smoke or strange smells are emitted from the Unit immediately remove the battery and stop using Continued use may cause fire or electrocution Please be careful not to touch the Unit during or after use in overly hot or cold environments
9. This will appear if the Unit cannot confirm a connec tion with the Input Module after having recognized it K with unit of display If nothing is displayed after reconnecting the sensor to the Unit there is a possibility that the sensor or the Unit has been damaged Sensor Unconnected or Damaged REC o c Ec p This will be displayed when a sensor has not been E rr connected to the module or the wire has been broken K Recording is in progress and so is battery consump tion If nothing appears on display after reconnecting the sensor to the Unit there is a possibility that the sensor or the Unit has been damaged Measurement Range Exceeded REC The message OL will appear if a measurement ex rm ceeds the measurement range Le 9 Display Range Exceeded When measuring voltage the measurement in the 70 o o o yz LCD display will blink if a measurement exceeds a set peatada display range Only when the Unit has been set to a fixed decimal point for display 4 Registering as a Remote Unit Communication with a PC In order to download data from the Unit via wireless communication or change recording settings in the Unit it is necessary to register a RTR 505 Unit as a Remote Unit to a Base Unit sold separately Remote Unit registration can be carried out by connecting the Base Unit to a PC via USB cable and using the software included with the Base Unit to carry ou
10. ation shall in no manner whatsoever take responsibility for the usage of these products nor be liable in any manner for legal consequences stemming from the usage of these wireless products in unapproved areas Without the module connected neither the module jack nor the connector part of the temperature sensor on the Unit is water resistant make sure not to get wet If the Unit is not to be used for a long period of time store it in a place where it is not exposed to high temperature and high humidity If the Unit has condensation on the inside it may cause malfunction and damage Do not remove or reinsert the battery once it has been set continue using until battery power is depleted Always use a new battery for replacement Not doing so may result in improper operation To maintain waterproof capacity we suggest periodically changing the parts inside the case If the rubber packing should be damaged or deteriorated please replace it along with the drying agent If the Unit is subjected to significant temperature change while wet it may cause condensation inside the case Especially be careful with temperature changes from high to low if the Unit has condensation on the inside it may cause malfunction damage and or unexpected accidents Do not drop or expose the Unit to a strong impact It may cause damage or malfunction Do not put fingers or foreign objects into the modular jack Soe Poe PBB
11. et TR 11P2 which includes an LS14250 When using an LS14250 type lithium battery even though a new battery has been inserted the battery warning mark may remain on for a short time This is due to a special characteristic of the battery Note that the longer the battery has been in storage the longer the amount of time from 10 minutes to about 1 hour the battery warning mark will remain on If during that time the Base Unit is used to get the current status of the Remote Unit the remaining battery level will show that the battery level is low Please store the lithium battery LS14250 in a place that is 20 C or less When changing a CR2 battery we strongly suggest changing the rubber packing and the drying agent Please purchase the maintenance set TR 00P1 sold separately man_users rtr505 1 eu indd 1 2 Connecting an Input Module Insert an Input Module into the module jack Once the Unit recognizes the module the LCD display will change as shown below and recording will start If you have purchased an RTR 505 P the Unit has been set by default to start recording upon installation of the battery The factory default settings are as follows Recording Interval 10 minutes and Recording Mode Endless Input Module LCD Displayed Items see the following section 3 Thermocouple Module TCM 3010 Measurement Unit of Measurement Sensor Type Operational Status Pt Module PTM 3010 Measurement Un
12. he Base Unit you can change the sensor type RTR 505 V Voltage REC Ermer ALS WLS VY Voltage measurement Unit V mV will be dis played Due to the wide measurement range the Unit has been set by default to adjust the decimal By using the software included with the Base Unit you can change the unit of display RTR 505 mA 4 20mA 4 20mA measurement Unit mA will be displayed point automatically to display the measurement in V Continued on Back Page gt gt 2011 08 25 15 19 45 How to Read the LCD Display continued from previous page RTR 505 P Pulse There are two display methods for the pulse measurement By using the software included with the Base Unit you can change the display method ree Pulse Rate Max 61439 D Ft FU p The most recent pulse count Unit P for the record h ha h ob ing interval period will be displayed The display K will be refreshed every one sixtieth of the recording interval at minimum of every one second 10 000 pulse count will be displayed as 10 00KP in units of 10 pulse for display fec Total Pulse Count Ftc i p The cumulative number of pulses Unit P will be A N 0 displayed from 0 to 9999 The displayed count will be refreshed every one second and upon exceed ing 9999 the count will start over again from 0 Other Marks or Messages on Display Logging Capacity FULL
13. it of Measurement Sensor Type Operational Status Voltage Module VIM 3010 Measurement Unit of Measurement Operational Status 4 20mA Module AIM 3010 Measurement Unit of Measurement Operational Status Set Model Number Measurement Item Temperature RTR 505 TC ype K J T 9 Temperature RTA 505 Pf Pt100 Pt1000 RTR 505 V Voltage Make sure that the module is completely RTR 505 mA 4 20mA inserted until you hear a click sound RTR 505 P Pulse Pulse Input Cable PIC 3150 Measurement Unit of Measurement Operational Status 3 How to Read the LCD Display When being used in very hot or cold environments the display may become difficult to read This is not a malfunction Basic LCD Display ONETIME C2 CF Oo cree TE Lim v PtKJTS mA The recording status will appear ON Recording in progress BLINKING Waiting for programmed start REC Mark ONETIME Mark When the recording mode is set to One Time this mark will appear The factory default setting is Endless and this mark will not appear Battery Warning Mark Measurements and Messages Area When it is time for the battery to be replaced this mark will appear Measurements or operational messages will ap pear here The type of sensor connected to or set in the Unit will appear Thermocouple Sensor K J T S Platinum Thermal Resistance Sensor Pt P
14. only Endless can be selected 3 The included lithium battery LS14250 is not sold in stores Please purchase the optional battery set for low temperature use TR 11P2 for replacement 4 Battery life varies depending upon the connected Input Module measuring environment frequency of communication Unit settings and battery performance For details see Estimated Battery Life in this manual 5 This is the waterproof capacity of a Unit with an Input Module connected Note that sensor connec tor of the Input Module is not water resistant Dust or defects on the packing can adversely affect the waterproof capacity in this case remove the dust or replace the pack Notes about Battery Installation After inserting the battery for the first time nothing may appear or occur for about 10 seconds this is not a malfunction If anew battery has been installed and nothing appears in the display please remove and reinsert the battery When inserting a battery make sure no water or foreign objects get inside the case Make sure that and are in the correct direction About Lithium Batteries Lithium batteries CR2 sold in stores may also be used but if you are using in an environment below 20 C above 60 C or ina situation such as transportation where continued vibration is likely to occur we strongly suggest the purchase and use of the our lithium battery LS14250 Please purchase the optional battery s
15. or any malfunction of and or trouble with this product or with your computer that is caused by the improper handling of this product and will deem such trouble or malfunction as falling outside the conditions for free repair outlined in the attached warranty All rights of this manual belong to T amp D Corporation It is prohibited to use duplicate and or arrange a part or whole of this Manual without the permission of T amp D Corporation All registered trademarks company names product names and logos mentioned herein are the property of T amp D Corporation or of their respective owners S Specifications design and other contents outlined in this manual are subject to change without notice Please follow the safety precautions outlined in this manual carefully We cannot guarantee nor are we responsible for safety if this product is used in any manner other than was intended On screen messages in this manual may vary slightly from the actual messages Please notify the shop where you purchased this product or T amp D Corporation of any mistakes errors or unclear explanations in this manual T amp D Corporation accepts no responsibility for any damage or loss of income caused by the use of our product This product has been designed for private or industrial use only It is not for use in situations where strict safety precautions are necessary such as in connection with medical equipment whether directly or indirectly We are not responsible
16. t optical communication with the Remote Unit For details about available operations via wireless communication or how to make recording settings see the Introductory Guide included with the Base Unit or see the application s Help Communicating with the Computer 1 Follow directions as issued in the software to connect the Base Unit to your PC Optical Communi cation Area Slitted Area man_users rtr505 1 eu indd 2 Communication with a PC enables the following By using a software included with the Base Unit it is possi ble to carry out Remote Unit registration change recording settings in the Unit download recorded data to a PC and view downloaded data The factory default settings are as follows Recording Interval 10 minutes Recording Start Immediate Start and Recording Mode Endless Notices about Optical Communication with a Base Unit Proper communication may not be possible in the following situations where tem peratures are very high or very low in an environment with intense brightness higher than 5 000Ix or when the remaining battery life for the Data Logger is very low The time necessary to download one RTR 505 Unit at full logging capacity varies depending upon the Base Unit being used Important Notices and Disclaimers In order to properly use this product please carefully read this manual before using T amp D Corporation accepts no responsibility f
17. t100 PtK Pt1000 The unit of measurement for the display will ap pear Sensor Type Unit of Measurement Battery Replacement 1 When it is time for the battery to be replaced a battery warning mark will appear ES 7 Please replace the battery as soon as possible if this D c mark appears v 09 Pt 2 If you do not change the battery and continue using the Unit the measurement display will intermittently display bAtt rec After this point the downloading of data can no c longer be done via wireless communication Without changing the battery and attempting to use optical communication to download recorded data the communication may be broken and if so all recorded data may be lost Recording will be continued nar m am rr rre v 3 If the battery is further left unchanged the display will automatically shut off If at this time a new battery is placed in the Unit r D q r CHEC will appear on the display after which record LIT L ing will begin again using the previously set recording conditions Note however that all previously recorded data will have been lost Estimated Battery Life When a battery warning mark appears try to replace the battery with a new one as soon as possible In a normal temperature environment where recorded data is downloaded once a day or if monitoring is carried out once every ten minutes
18. th the manual the Unit shall be repaired free of charge through the distributor which sold the Unit 2 If the customer requests free repair because of trouble within the warranty period bring or send the Unit along with the warranty to the distributor 3 If you have moved after purchasing or there are difficulties contacting the distributor from which you purchased the Unit please contact T amp D directly for service 4 Free repair is not available in the following cases even though it is within the warranty period 1 Trouble or damage was caused by careless operation natural disaster fire public pollution or use of a power source other than specified 2 If repair adjustment disassembly or modification of the Unit has been carried out by a person other than a T amp D authorized engineer 3 Trouble or damage was caused by transportation movement or dropping of the Unit after pur chase 4 Failure to submit the Warranty or failure to fill in all items required in the Warranty 5 The Warranty cannot be reissued This Warranty only promises customers free repair within the period and conditions clarified in this Warranty Therefore the customer s legal rights will not be limited by this Warranty For further infor mation on repair and other service questions after the termination of the warranty period contact your distributor T amp D corporation 2011 08 25 15 19 46