Home
EKI-2701PSI User Manual
Contents
1. 2 1 1 3 Wide Operating Temperature 2 1 2 Feat r S ern a Dar a hei ee 3 1 8 Specification see 4 1 4 PACKING ES au 6 1 5 Safety Precaution ran 6 Chapter 2 Installation ccccseeeeeesesseeeeees 8 2 1 WED UGC ALORS anne ee 8 Table 2 1 EKI 2701PSI LED Definition 8 2 2 Dimensions units mm en 9 Figure 2 1 Front View of EKI 2701PSI series 9 Figure 2 2 Side View of EKI 2701PSI series 10 Figure 2 3 Rear View of EKI 2701PSI series 11 Figure 2 4 Top View of EKI 2701PSI series 12 2 3 MOURING ae sen 13 2 3 1 Wal MOURUNG Stee en ee 13 Figure 2 5 Combine the Metal Mounting Kit units PIAL PR EENTTEREE NE STEH E EE N 13 2 3 2 DIN rail Mounting 0 44444 400 14 Figure 2 6 Installation to DIN rail Step 1 14 Figure 2 7 Installation to DIN rail Step 2 15 2 4 Network Connection uueseneeeneeeeen een een een 16 2 5 Power Connection 17 Figure 2 13 Pin Assignment of the Power Connector 17 Chapter 3 Troubleshooting cccssseseeee 20 Appendix A Pin Assignment amp Wiring 22 Figure A 1 RJ 45 Pin Assignment 22 Figure A 2 ETA TIA 568B cesceeserseeeesseeseneees 22 Figure A 2 EIA TIA 568A eseese 23 vii Contents EKI 2701PSI User Manual_ed1 viii CHAPTER Overview Sections include e Introducti
2. Certifications Safety UL 60950 1 CAN CSA C22 2 No 60950 EMC U S A FCC Part 15 CISPR 22 EU EN55011 EN61000 6 4 EN55022 Class A EN61000 3 2 3 EN55024 IEC61000 4 2 3 4 6 8 EN61000 6 2 4 Free Fall IEC60068 2 32 Shock IEC60068 2 27 Vibration IEC60068 2 6 5 Chapter 1 4 Packing List e 1x EKI 2701PS Series Industrial PoE Splitter e 1 x eAutomation Industrial Communication CD ROM with software and User manual e 2x Panel Mounting Bracket and Screws e 1x DIN rail Mounting Bracket and Screws e 1x EKI 2701PSI Startup Manual 1 5 Safety Precaution Attention IF DC voltage is supplied by an external circuit please use a protection device on the power supply input EKI 2701PSI User Manual_ed1 6 CHAPTER Installation Sections include e LED Indicators e Dimensions e Mounting e Network Connection e Power Connection Chapter 2 Installation In this chapter you will be given an overview of the EKI 2701PSI hardware installation procedures 2 1 LED Indicators There is an LED displaying the power status located on the front panel of EKI 2701PSI Table 2 1 EKI 2701PSI LED Definition LED Color Description On Power input is active Power Green Off Power input is inactive EKI 2701PSI User Manual_ed1 8 2 2 Dimensions units mm 15 00 e 11 05 Figure 2 1 Front View of EKI 2701PSI series 9 Chapter2 A O00 eet 104 00 Figure 2 2 Side View of EKI 2701P
3. EKI 2701PSI Industrial PoE Splitter Wide Temperature User Manual Copyright The documentation and the software included with this product are copyrighted 2007 by Advantech Co Ltd All rights are reserved Advantech Co Ltd reserves the right to make improvements in the products described in this manual at any time without notice No part of this manual may be reproduced copied translated or transmitted in any form or by any means without the prior written permission of Advantech Co Ltd Information provided in this manual is intended to be accurate and reliable However Advantech Co Ltd assumes no responsibility for its use nor for any infringements of the rights of third parties which may result from its use Acknowledgements Intel and Pentium are trademarks of Intel Corporation Microsoft Windows and MS DOS are registered trademarks of Microsoft Corp All other product names or trademarks are properties of their respective owners Part No 1st Edition Printed in China February 2008 EKI 2701PSI User Manual_ed1 ii Product Warranty 2 years Advantech warrants to you the original purchaser that each of its products will be free from defects in materials and workmanship for two years from the date of purchase This warranty does not apply to any products which have been repaired or altered by persons other than repair personnel authorized by Advantech or which have been subject to misuse abuse accident or impr
4. SI series EKI 2701PSI User Manual_edl 10 3 50 3 50 Figure 2 3 Rear View of EKI 2701PSI series 11 Chapter2 The terminal block for power output is located on the top side Please refer to page 16 for pin assignment Figure 2 4 Top View of EKI 2701PSI series EKI 2701PSI User Manual_ed1 12 2 3 Mounting The EKI 2701PSI support two mounting methods DIN rail amp Wall 2 3 1 Wall mounting EKI 2701PSI can be wall mounted by using the included mounting kit Then hang on the EKI 2701PSI to the nails on the wall First use the screws included in the package to combine the EKI 2701PSI and metal mounting kit And then you can install the device firmly via the components please see Figure 2 5 as below EKI 2300x 158 00 Figure 2 5 Combine the Metal Mounting Kit units mm 13 Chapter2 2 3 2 DIN rail Mounting You can also mount EKI 2701PSI on a standard DIN rail by following the steps below The DIN rail kit is screwed on the industrial switch when out of factory If the DIN rail kit is not screwed on the industrial switch please screw the DIN rail kit on the switch first First hang the EKI 2701PSI to the DIN rail with angle of inclination See figure 2 6 Figure 2 6 Installation to DIN rail Step 1 EKI 2701PSI User Manual_edl 14 Then let the device down straight to slide over the rail smoothly See Figure 2 7 Figure 2 7 Installation to DIN rail Step 2 15 Chapter2 2 4 Network C
5. e and ship it prepaid to your dealer iii Declaration of Conformity CE This product has passed the CE test for environmental specifications Test conditions for passing included the equipment being operated within an industrial enclosure In order to protect the product from being damaged by ESD Electrostatic Discharge and EMI leakage we strongly recommend the use of CE compliant industrial enclosure products FCC Class A This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Technical Support and Assistance Step 1 Visit the Advantech web site at www advantech com support where you can find the latest information about the product Step 2 Contact your distributor sales representative or Advantech s customer service center for technical support if you need additional assistance Please have the following information ready before you ca
6. ll Product name and serial number Description of your peripheral attachments Description of your software operating system version application software etc Acomplete description of the problem The exact wording of any error messages EKI 2701PSI User Manual_ed1 iv Safety Instructions 1 2 3 an 10 11 12 13 14 15 Read these safety instructions carefully Keep this User s Manual for later reference Disconnect this equipment from any AC outlet before cleaning Use a damp cloth Do not use liquid or spray detergents for cleaning For plug in equipment the power outlet socket must be located near the equipment and must be easily accessible Keep this equipment away from humidity Put this equipment on a reliable surface during installation Dropping it or letting it fall may cause damage The openings on the enclosure are for air convection Protect the equipment from overheating DO NOT COVER THE OPENINGS Make sure the voltage of the power source is correct before connecting the equipment to the power outlet Position the power cord so that people cannot step on it Do not place anything over the power cord All cautions and warnings on the equipment should be noted If the equipment is not used for a long time disconnect it from the power source to avoid damage by transient overvoltage Never pour any liquid into an opening This may cause fire or electrical shock Never ope
7. n the equipment For safety reasons the equipment should be opened only by qualified service personnel If one of the following situations arises get the equipment checked by service personnel a The power cord or plug is damaged b Liquid has penetrated into the equipment c The equipment has been exposed to moisture d The equipment does not work well or you cannot get it to work according to the user s manual e The equipment has been dropped and damaged f The equipment has obvious signs of breakage DO NOT LEAVE THIS EQUIPMENT IN AN ENVIRONMENT WHERE THE STORAGE TEMPERATURE MAY GO BELOW 40 C 40 F OR ABOVE 85 C 185 F THIS COULD DAMAGE THE EQUIPMENT THE EQUIPMENT SHOULD BE IN A CONTROLLED ENVIRONMENT Safety Precaution Static Electricity Follow these simple precautions to protect yourself from harm and the products from damage 1 To avoid electrical shock always disconnect the power from your PC chassis before you work on it Don t touch any components on the CPU card or other cards while the PC is on 2 Disconnect power before making any configuration changes The sudden rush of power as you connect a jumper or install a card may damage sensitive electronic components EKI 2701PSI User Manual_ed1 vi Contents Chapter 1 OVervieW scsseseeeeeeeseeseeeeeees 2 14 Intoduelen sen See aed 2 1 1 1 Flexible Mounting 2ss044000 seen 2 1 1 2 Advanced Protection
8. on e Features e Specifications e Packing List e Safety Precaution Chapter1 Overview 1 1 Introduction With the technology of PoE Power over Ethernet we can transfer both data and electrical power to Ethernet enabled devices using a standard Ethernet CAT5 cable EKI 2701PSI plays the role of powered device PD and splits power from PoE to Ethernet devices In this case both power and data can be transmitted up to 328 feet 100m from power source equipment PSE This product can operate in a wide range of temperature between 40 and 75 C and the rugged hardware design makes EKI 2701PSI perfect to ensure your PoE Ethernet equipment can meet industrial applications demanding 1 1 1 Flexible Mounting EKI 2701PSI is compact and can be mounted on a DIN rail or a panel so it is suitable for any space constrained environment 1 1 2 Advanced Protection The power line of EKI 2701PSI supports up to 3 000 Vpc EFT protection which secure equipment against unregulated voltage and make systems safer and more reliable Meanwhile 6 000 Vpc ESD protections for Ethernet ports make EKI 2701PSI more suitable for harsh environments 1 1 3 Wide Operating Temperature The operating temperature of the EKI 2701PSI is between 40 75 C With such a wide range you can use the EKI 2701PSI in some of the harshest industrial environments that exist EKI 2701PSI User Manual_ed1 2 1 2 Features Supports 10 100 1000T for PoE in and Data out Po
9. onnection Use the four twisted pair Category 5e cabling for RJ 45 port connection The cable between the splitter and the non PoE device must be less than 100 meters 328 ft EKI 2701PSI User Manual_ed1 16 2 5 Power Connection The EKI 2701PSI supports dual 24Vpc power outputs OUUU Lad Oy ygd Output DC24V Figure 2 13 Pin Assignment of the Power Connector Insert the positive and negative wires into the V and V contacts on the terminal block connector Users can wire the ground contact to the ground of the device whose power input connects to this splitter 17 Chapter2 EKI 2701PSI User Manual_ed1 18 CHAPTER Troubleshooting Chapter 3 Troubleshooting 1 Power Input Verify that the splitter is using the right power source 44 57V5c 2 Cable Select the proper UTP cable to construct your network Please check that you are using the right cable 3 Diagnosing LED Indicator If the power indicator does not light up when the PoE In port is connected to a power source equipment PSE via the UTP cable check for loose cable connections power losses or surges at power outlet If you still cannot resolve the problem contact the local dealer for assistance EKI 2701PSI User Manual_ed1 20 A Pin Assignment amp Wiring APPENDIX Appendix A Pin Assignment amp Wiring It is suggested to adopt ELA TIA as the wiring of the RJ 45 Figure A 1 RJ 45 Pin Assignment RJ 45 ports 10 100 1000Mbps p
10. oper installation Advantech assumes no liability under the terms of this warranty as a consequence of such events Because of Advantech s high quality control standards and rigorous testing most of our customers never need to use our repair service If an Advantech product is defective it will be repaired or replaced at no charge during the warranty period For out of warranty repairs you will be billed according to the cost of replacement materials service time and freight Please consult your dealer for more details If you think you have a defective product follow these steps 1 Collect all the information about the problem encountered For example CPU speed Advantech products used other hardware and software used etc Note anything abnormal and list any onscreen messages you get when the problem occurs 2 Call your dealer and describe the problem Please have your manual product and any helpful information readily available 3 If your product is diagnosed as defective obtain an RMA return merchandize authorization number from your dealer This allows us to process your return more quickly 4 Carefully pack the defective product a fully completed Repair and Replacement Order Card and a photocopy proof of purchase date such as your sales receipt in a shippable container A product returned without proof of the purchase date is not eligible for warranty service 5 Write the RMA number visibly on the outside of the packag
11. orts are auto sensing for 10Base T 100Base TX or 1000Base T connections Data pins for PoE IN port 1 2 3 6 4 5 7 and 8 Power pins for PoE IN port 4 5 V 7 8 V or 1 2 V 3 6 V Data pins for DATA OUT port 1 2 3 6 4 5 7 and 8 Power output located on the top side 1 x 6 pin terminal block el Pin ree EKI 2701PSI User Manual_ed1 Figure A 2 EIA TIA 568B 22 A amp Ww N m 6 7 8 White Orange Orange White Green Blue White Blue Green White Brown Brown Pin 1 Pin8 Figure A 2 EIA TIA 568A 23 1 White Green 2 Green 3 White Orange 4 Blue 5 White Blue 6 Orange 7 White Brown 8 Brown Chapter2
12. wer Isolation and Short circuit protection for power output Auto disconnection for over power voltage input Supports output power up to 12 95W at 24Voc Wide range Power Design Supports surge EFT protection 3 000 Vpc for power line Supports 4 000 Vpc Ethernet ESD protection Provides flexible mounting DIN rail Wall Mounting IP 30 Protection Supports operating temperatures from 40 75 C Chapter 1 3 Specification Communications Standard LAN Transmission Distance Transmission Speed Switch Architecture Interface Connectors LED Indicators Power Power Input Power Consumption Power Output Mechanism Dimensions W x D x H Enclosure Mounting Protection ESD Ethernet Surge EFT for power Overload current protection Environment Operating Temperature Storage Temperature Operating Humidity Storage Humidity EKI 2701PSI User Manual_ed1 IEEE 802 3 802 3u 802 3ab 802 3af 10 100Base TX 1000Base T Up to 100 meters UTP Up to 1000 Mbps Store and Forward 2 x 10 100 1000Base T RJ 45 ports 6 pin removable screw terminal power output TX port 10 100 1000M Link Active Fiber port LNK ACT Port Alarm LFP 44 57Voc 17 76W at 48Voc 12 95W Max 0 539A 24Voc 37 x 95 x 140 mm IP30 Metal shell with solid mounting kits DIN rail wall 4 000 Voc 3 000 Voc 0 539A 24Voc 40 75 C 40 167 F 40 85 C 40 185 F 5 95 non condensing 0 95 non condensing
Download Pdf Manuals
Related Search
Related Contents
Swan SI9021BMN steam ironing station Ikelite Nikonos TTL Cord Film Camera User's Manual APart STSUB 取扱説明書(SL50シリーズ/SL55シリーズ) accident avoidance and track failure identification syytem in south 15 白鳥八幡宮古式祭礼 Miele KM5944 Cooktop User Manual JR3060T JR3070CT こちらへ - JARL.com Copyright © All rights reserved.
Failed to retrieve file