Home
User Recommendations for RF
Contents
1. 4 Core Lab User Recommendations for RF Safe Green DET 2 300750 1 MAN DET RF RO3 OWEN OIL TOOLS 12001 Cr 1000 Godley Texas 76044 USA Phone 1 817 551 0540 Fax 1 817 551 1674 www corelab com owen Warning use of owen equipment contrary to manufacturer s specifications or operating instructions may result in property damage serious injury or fatality If you are not trained in the handling and use of explosive devices do not attempt to use or assemble any owen perforating systems or owen firing devices This technology is regulated by and if exported was exported from the united states in accordance with the export administration regulations EAR Diversion contrary to U S Law is prohibited Export and or re export of this technology may require issuance of a license by the bureau of industry and security BIS U S Department of Commerce Consult the BIS the EAR and or Owen Compliance Services Inc To determine licensing requirements for export or re export of this technology This document contains confidential information of Owen Oil Tools LP Owen and is furnished to the customer for information purposes only This document must not be reproduced in any way whatsoever in part or in whole or distributed outside the customer organization without first obtaining the express written authorization of owen This document is the property of owen and returnable upon request of Owen 2015 Owen Oil Tools All right
2. alloped gun systems where a fluid disabled detonator will prevent the detonation of a flooded gun when used properly Fluid migrating through the fluid holes in the body of the crimp sleeve will prevent the detonator from initiating the detonating cord The detonator and crimp sleeve accessory is designed to be used with the following detonating cords e 80gr ft PETN Not fluid disabled or interruptible w PETN detonating cord 80gr ft HMX e A0gr ft HMX LS e 80gr ft HMX LS e 40gr ft HMX LS Ribbon e 80gr ft RDX e 40gr ft RDX LS e 80gr ft RDX LS e 40gr ft RDX LS Ribbon 2 MAN DET RF R03 2015 Owen Oil Tools All rights reserved RF Safe Green DET Core Lab Note Deicord adapters must be used with 40 gr ft Ribbon detonating cord Sold separately and packaged individually by Owen Oil Tools P N DET 0010 006 Note Crimp sleeves sold separately and packaged individually by Owen Oil Tools P N DET 0010 074 T Caution Owen Super Crimpers are designed to consistently create the proper crimping configuration Use of any other crimping device could result in a misfire caused by an inadequate crimp or damaging the detonator The user should satisfy themselves as to the suitability of this product for the user s application Please refer to the Owen Oil Tool s Technical Specifications sheet Owen Document 2 300750 1 DS 01 for more information Green DET for Pipe Recovery Applicati
3. andling 2 1 2 Slide the green stainless steel crimp sleeve onto the output end of the detonator making sure to slide the end with the slits onto the detonator The figure below shows an example Slide on crimp sleeve with slits and dimple as shown Detcord end Slide crimp sleeve until it is flush with this shoulder Fluid Hole 2015 Owen Oil Tools All rights reserved MAN DET RF R03 I5 ke Core Lab RF Safe Green DET Make sure the crimp sleeve sits flush with the shoulder of the detonator The crimp sleeve should be snug on the detonator The finished product should look like this 2 1 5 2 1 6 Insert the detonator into a detonator safety tube P N DET 2000 000 and secure the lid shut The resistance may be checked at this time Make sure panel is safe key is removed and outside the unit and verify no voltage is measured on the wireline With the detonator still in the safety tube electrically connect the detonator to the wireline cable by attaching the red wire to hot lead and the blue wire to ground The detonator is now electrically armed and it may now be removed from the safety tube Carefully make a square clean cut of the detonating cord using the Owen Super Cutters P N DET 0000 036 Insert the newly cut end of the detonating cord into the open end of the crimp sleeve until it becomes flush with the fluid hole see figure below If using 40 gr ft Ribbon detcord then use Owen s detcord ada
4. moved from the safety tube 2 3 6 With the detonator removed from the safety tube install the booted portion of the detonator over the end of the extension adapter Gree RUBBER RETAINER EXTENSION ADAPTER TOU iaa 2 3 7 Insert the detonator output end first into the cutter top sub and thread the top sub onto the extension adapter The detonator end should be roughly 0 040in recessed from the bottom of the cutter top sub rey 04 EXTENSION ADAPTER A GreenDet w RUBBER RETAINER Note Top Subs and Extension Adapters will vary Please refer to the Owen User Manual specific to the cutter system being used for more details on hardware and procedures 2 3 8 Make sure the top sub s o ring is lightly lubricated with grease and thread the explosive cutter load components onto the top sub being careful not to force pinch crush or impact the explosive components The ballistic arming is now complete 8 MAN DET RF RO3 2015 Owen Oil Tools All rights reserved Core Lab RF Safe Green DET Note Please refer to Owen s Cutter User Manual specific to the cutter system being used This manual will contain more specific information and instructions regarding the cutter assembly being used 3 0 Ballistic Transfer Interrupter STOP Warning Owen s Ballistic Interrupter device is NOT compatible with any type of PETN based detonating cord Due to PETN s sensitivity it may still be able to pick up
5. on the voltage meter panel when 300V DC is applied to the multi meter This location will indicate that you are applying 300V DC to the gun string 1 2 Reset panel to safe mode 1 3 Continue proper assembly of toolstring 1 4 When ready to fire the gun or detonator downhole increase the power to the firing circuit from OV DC to the marked needle location that corresponds to 300V DC The detonator will fire anywhere between 55V and 300V Note The user will not see any current being applied to the detonator when ramping up on the rheostat dial However the voltage should continue to ramp up until the detonator fires 4 MAN DET RF R03 2015 Owen Oil Tools All rights reserved ke Core Lab RF Safe Green DET 2 0 Arming Warning Detonators should only be removed from their and in the loading arming area at the time of arming Always insert the detonator inside an Owen Detonator Safety Tube Part DET 2000 000 after removal from packaging and storage Note An electrical check of the detonator s firing circuit may be conducted while the detonator is confined within a safety tube Using electrical blasters multi meter the RF Safe Green DET will measure between from 0 800 MO to 1 100 MO 2 1 RF Safe Detonator with Crimp Sleeve Accessory 2 1 1 Remove both the Green DET P N 2 300750 1 and green stainless steel crimp sleeve P N DET 0010 074 from their packaging Keep the detonator shunted during h
6. ons ee a TN The Green D jis compatible with all Owen s Split Shot and Cutter ACE NT Segmented etc products For Owen Cutter products the rubber retainer accessory P N DET 0100 113 must be used in order for the detonator to be properly installed into the cutter hardware Please Section 2 0 for general installation and arming procedures using the Green DET Note Please refer to the Owen User Manual specific to the pipe recovery system being used This manual will contain more specific information and instructions regarding the pipe recovery system being used MAN DET RF R03 3 2015 Owen Oil Tools All rights reserved Core Lab RF Safe Green DET Caution Do NOT crimp directly onto the Green DET The detonator is not designed to be directly crimped and will damage the detonator if performed The user should satisfy themselves as to the suitability of this product for the user s application Please refer to Owen Oil Tool s Technical Specifications sheet Owen Document 2 300750 1 DS 02 for more information 1 0 Procedures for Panel Setup and Firing Green DET 1 1 Prior to arming or gun make up e Measure the voltage output from the panel with a digital blasters multi meter at the cablehead CCL or Quick Change Verify a minimum of 300V DC output can be applied from the panel to the meter Note Mark the location of the needle
7. pter P N DET 0010 006 The fluid hole should not be filled or covered by explosive powder detonating cord tape etc as this could prevent the detonator from being fluid disabled Crimp the cord in place in a 3 8 in 0 95cm area from the end of the crimp sleeve using Owen Super Crimpers P N DET 0100 053 The detonator is now ballistically armed and the finished product should look something like the figure below Detcord flush with fluid hole DO NOT COVER THE FLUID HOLE ATTACHED TO WIRELINE CABLE CRIMP AREA WITHIN 3 8 OF END 6 MAN DET RF RO3 2015 Owen Oil Tools All rights reserved Ly Core Lab RF Safe Green DET 2 1 7 Complete the mechanical assembly of the device and tool assembly taking care not to force pinch crush or impact the explosive components or wiring Be sure the green crimp sleeve is still attached properly and flush with the end of the detonator 2 2 Green DET for Owen Split Shot 2 2 1 Remove the Green DET from its packaging Keep the detonator shunted during handling 2 2 2 Insert the detonator into a detonator safety tube P N DET 2000 000 and secure the lid shut The resistance may be checked at this time 2 2 3 While keeping the detonator in the safety tube insert the shunted wires of the detonator through the hole in the top sub 2 2 4 Make sure the firing panel is safe key is removed and outside the unit and verify that no voltage is measured on the
8. s reserved Core Lab RF Safe Green DET STOP Warning Explosives are destructive by nature Do not attempt to disassemble or alter the detonator in any manner Do not crush hammer pinch impact pull wires or abuse the detonator or any explosive STOP Warning Be sure to follow safe operating practices as found in API RP 67 in accordance with governmental regulations company policies and manufacturer s recommendations Owen Oil Tool s and Pacific Scientifics RF Safe Reactive Semi Conductor Bridge RSCB Detonators are designed to detonate a lead free energetic material when an electrical voltage greater than 55 volts is applied This allows the detonator to be fired with any standard 300V 2A firing panel in wireline operations The RF Safe RSCB Detonator is manufactured to API RP 67 recommendations and has been tested and verified by Franklin Applied Physics to withstand up to 10 GHz frequency at 100 V m field strength This detonator will withstand temperatures of 40 F to 400 F for1 hr while still maintaining a 99 99 initiation reliability 95 confidence For more technical information regarding this detonator please refer to Owen Oil Tool s Technical Specifications sheet Owen Document 2 300750 1 DS Green DET with Crimp Sleeve Accessory DET 0010 074 When used with the green crimp sleeve accessory P N DET 0010 074 the Green DET is designed to be used in hollow steel carrier or sc
9. than Owen s INT 3050 125I Extensive testing has been performed by Owen Oil Tools to ensure reliability and confidence when using this specific interrupter part 3 1 3 To interrupt the ballistic transfer the interrupter device must be purchased from Owen Oil Tools part INT 3050 125I Place the interrupter into the detonator crimp sleeve s fluid hole making sure that it is fully inserted with part of the interrupter sticking out of both sides of the crimp sleeve The interrupter will fit snugly The below figure shows the interrupter in place The interrupter can also be removed through a sub port 10 MAN DET RF RO3 2015 Owen Oil Tools All rights reserved
10. the shock from the detonator and initiate high order In no circumstances should Owen s interrupt device be used and transported with PETN detonating cord Please see compatible detonating cords in Section 3 1 3 1 Green DET with Crimp Sleeve Accessory 3 1 1 When used with the green crimp sleeve this detonator can use an Owen Interrupter to prevent ballistic transfer from the detonator to the detonating cord With the interrupter in place the detonating cord will not detonate Please see warning above This feature may aid in the transport of an armed gun system following all applicable local and federal regulations Please note this transportation is for the United States only and it is at the discretion of each company whether they choose to use this option 3 1 2 The following detonating cord types are compatible with the Green DET with Crimp Sleeve Accessory P N DET 0010 074 and Owen Interrupter P N INT 3050 125l1 80gr ft RDX LS e 40gr ft RDX LS 80gr ft RDX LS 40gr ft RDX LS Ribbon 80gr ft RDX e 40gr ft HMX LS e 80gr ft HMX LS e 40gr ft HMX LS Ribbon e 80gr ft HMX Note Detcord adapters must be used with 40 gr ft Ribbon detonating cord Sold separately and packaged individually by Owen Oil Tools P N DET 0010 006 2015 Owen Oil Tools All rights reserved MAN DET RF R03 19 Core Lab RF Safe Green DET STOP Warning Do NOT use any other type of interrupter device other
11. wireline 2 2 5 With the detonator still in the safety tube electrically connect the detonator to the wireline cable by attaching the red wire to hot lead and the blue wire to ground The detonator is now electrically armed and it may now be removed from the safety tube 2 2 6 For all remaining steps please refer to the Owen User Manual specific to the Split Shot system being used This will contain specific information to the Split Shot and how to complete the ballistic arming procedure 2 3 Green DET with Rubber Retainer Accessory for Owen Cutters 2 3 1 Remove the Green DET with rubber retainer accessory from its packaging Keep the detonator shunted during handling 2 3 2 Insert the detonator into a detonator safety tube P N DET 2000 000 and secure the lid shut The resistance may be checked at this time 2 3 3 While keeping the detonator in the safety tube insert the shunted wires of the detonator through the male end of the shock sub extension mandrel 2015 Owen Oil Tools All rights reserved MAN DET RF R03 I7 ke Core Lab RF Safe Green DET 2 3 4 Make sure the firing panel is safe key is removed and outside the unit and verify that no voltage is measured on the wireline 2 3 5 With the detonator still in the safety tube electrically connect the detonator to the wireline cable by attaching the red wire to hot lead and the blue wire to ground The detonator is now electrically armed and it may now be re