Home

OCS User Guide OCS-A,B,C,G,Z

image

Contents

1. lock unlock 47 Hold with LA enter User Setup confirm 2nd function a 2nd with AJ enter Password mode exit and save Remote Keys key name function Ter Zero same as or P Tare same as Cr Cy Hold sameas Zei accumulate weight el Acc with A J switch resolution decrease digital delete last weight e Del with LA clear all weight left scroll digital View E SE weight n with LA view battery power e n NC 2 Off same as Le e 2nd same as a Indicators indicator name note STB stable lit when weight is stable ZERO Zero lit when weight is at zero Page 4 of 15 High Resolution Digital Crane Scale User Guide TARE tare lit when scale is tared HOLD hold lit when scale is locked Ib Ib lit when unit is Ib kg kg lit when unit is kg Message message stand for note UT weight over range EES detect weight Sege weight below range 5EEU SETUP User Setup E nd END save and exit BEF OFF power off i overload exceeds 100 ould OVerLoaD et g od 2ND 2nd function hol HOLD scale is locked Un 5t b UNSTaBle load not stable EArE TARE scale is tared Un PG UNit KG kg Un L UNit LB lb UnuSr UNit USeR User Unit out INVaLiD invalid operation E E ACCumulate accumulate weight naHLL NO ACCumulate no weight accumulated nad E L NO DELete no weight deleted dEL D
2. F S Zero Range 4 F S Stable Time lt 10sec Overload 100 F S 9e Safety Load 125 F S Ultimate Load 400 F S Battery 6V 10Ah 6V 5Ah or 6V 3 2Ah lead acid battery Charger AC220V input DC9V 1500mA output Op Temp 10 C 40 C Op Humidity 20 C 9096 38 1mm 1 5inch or 30mm 1 2inch LED Display 35mm LCD 4 Capacity modal resolution division max cap min cap Page 2 of 15 High Resolution Digital Crane Scale User Guide OCS 005 50kg 0 4kg 0 02kg 2 500 OCS 01 100kg 1kg 0 05kg 2 000 OCS 02 200kg 2kg 0 1kg 2 000 OCS 03 300kg 2kg 0 1kg 3 000 OCS 05 500kg 4kg 0 2kg 2 500 OCS 1 1 000kg 10kg 0 5kg 2 000 OCS 2 2 000kg 20kg 1kg 2 000 OCS 3 3 000kg 20kg 1kg 3 000 OCS 5 5 000kg 40kg 2kg 2 500 OCS 10 10 000kg 100kg 5kg 2 000 OCS 15 15 000kg 100kg 5kg 3 000 OCS 20 20 000kg 200kg 10kg 2 000 OCS 30 30 000kg 200kg 10kg 2 000 OCS 50 50 000kg 400kg 20kg 2 500 5 Display amp Keys Scale Keys key name function press for 1sec power on scale OV On Off press for 1sec power off scale exit without saving zero scale or Zero with aj unit switch increase digital tare in out VC Tare with LA tare set right scroll digital Page 3 of 15 High Resolution Digital Crane Scale User Guide
3. performance at 2000 to 3000 division Press 8 J or LJ enter Auto Off Auto Off Time Scale displays auto off time e g O F Fi 5 indicating 15min Press co or je and le change Auto Off time Press VO V or IL exit without saving Press Za or 8 exit and save Auto Off function maximizes scale s battery life against people s carelessness not to power off scale when it s not working Page 10 of 15 High Resolution Digital Crane Scale User Guide K G Ki C AAO H Er Auto Off starts countdown timer when there s no action or load is stable Any key pressing or motion in load restarts countdown timer Auto Off time can be set to 0 never auto off 5min 15min 30min 60min Press Le or m enter Idle Mode Idle Time Scale displays idle time eg dl JG indicating 30sec Press voy or TE and le change idle time Press VO V or 8 exit without saving Press Za or 8 exit and save To maximize battery life scale automatically enters Idle Mode when there s no action or the load is stable In Idle Mode scale works in low power consumption status Any key pressing or motion in load wakes up scale from Idle Mode Idle time can be set to 0 never ilde 5sec 15sec 30sec 60sec Press Zei or enter Brightness Backlight Brightness Backlight Scale displays LED brightness LCD backlight status Pre
4. ELete delete last weight CLERA CLEAR delete all weight Page 5 of 15 High Resolution Digital Crane Scale User Guide nnnn LILI LI LI Password Password mode 6 Operations EN 4 GR eOooO0LiR rd On Off Press w for 1sec power on scale Scale performs initialization and boot up testing then display flashes 3 times and displays max cap battery power then detects weight and Auto Zero For information about Auto Zero refer to Scale Setup in Technical Manual Press w or for 1sec power off scale Scale displays battery power and off message then cut off power Zero Press or or CR zero scale Indicator ZERO lights on Scale must not be locked otherwise Mota displays Scale must be stable otherwise Do DE B displays Scale must not be tared otherwise LACE displays Weight must be in Manual Zero Range otherwise displays For information about Manual Zero Range refer to Scale Configuration in Technical Manual Tare In Tare Out In gross mode press Cer or CH tare scale Indicator TARE lights on Scale must not be locked otherwise Mold displays Page 6 of 15 High Resolution Digital Crane Scale User Guide L5 095 CNOCN OOR GN BEES Scale must be stable otherwise Do GE E displays Weight must exceed 0 otherwise __ _ _ Weight must be lighter than 100 F S otherwise displays Tare will reduce the apparent overload
5. OCS Series High Resolution Digital Crane Scale User Guide 1 Safetv EE EE 1 been tt tee EE EN EE 1 3 Specifications ee ee ee ee ee ee ee 2 Scale GR EE EE EED 3 Remote Keys ease EE ee 4 Indicators 3 idea a ue eee E 4 leegen ee 5 6 Operations sii tei ee diee IR taal 6 Fare In Tare Qut uideri oie GER Ge N SR Ee SR eed 6 Lock 7 Unlock asistir geesde 7 Accumulate 25 tt ee tete adhe eme dette 7 EE EE OE EE OO Ed 8 BOERE ER N EE OE EE 8 SI EE RO EE OR Aa EIE 8 died aie ER EE EE EE EE itg 8 Tare Set OR EE aom tes 9 Resolution Switch Battery Power View sss 10 EE E 10 Resolution EE 10 Auto Off TIME EE 10 TdleTime ss ER add deo 11 Brightness Backlight see 11 ARNHEMOHON nne tee p Ree 12 8 Battery Maintenance see see oe oge goe oge tienes 12 9 Troubleshooting ee se ee ee ee ee 13 AE EE 15 Please read this manual carefully before using Rev V1 0A 1 High Resolution Digital Crane Scale User Guide 1 Safety Guide For good performance and precise measurement be careful with daily operation and maintenance Do NOT overload scale This will damage loadcell and void warranty Do NOT leave load hung on the scale for long This will decrease scale s accuracy and shorten loadcell s life Inspect shackle and hook before using Check clips pins and screws regularly Check battery frequently When scale runs out of power c
6. cost of longer measuring time and stricter requirement of load s stability Designed to meet the OIML R76 s directive the scale has the best default performance at 2000 to 3000 division Resolution Switch changes the apparent overloading range of scale For example if a 3000 1kg scale is switched to 3000 0 5kg it will overload at 3004 5kg 3000 9 0 5 while by default it overloads at 3009kg 3000 9 1 Default resolution will be restored next time when scale is powered on or enter User Setup To save changes in resolution for later enter User Setup and change Resolution For information about Resolution refer to User Setup Page 9 of 15 High Resolution Digital Crane Scale User Guide ON Battery Power View Press a or P and then press to view battery power Fi Scale displays battery voltage for example Uu B j B indicating 6 38V For information about battery refer to Battery Maintenance 7 User Setup M SIE N G KA G AAG Li Press a or P and then press Zei or i enter User Setup mode Message 5E E UD displays Press Le or m enter Resolution Resolution Scale displays resolution to be set For example E 05 indicating resolution is set to 0 5 Press oo or je and le change resolution Press w or 95 exit without saving Press a or e exit and save Designed to meet the OIML R76 s directive the scale has the best default
7. eletes the last weight Scale must not be locked otherwise hold displays If last accumulated weight has been deleted nod EL displays Clear Press 4 7 or 8 then press 8 clear all weight CLERA displays indicating all weight is cleared Unit Switch Press L or P then press To switch unit in between kg lb USR When unit switches to kg Un P G displays indicator kg lights on When unit switches to lb Un Lb displays indicator Ib lights on When unit switches to USR Hnt Sr displays indicator Kg and Ib lights off Unit Switch changes unit temporarily Scale does not save unit unless System Unit is changed For more information about USR refer to Scale Configuration in Page 8 of 15 High Resolution Digital Crane Scale User Guide KG BR BOOR E Technical Manual Tare Set In gross mode press fag or then press Cr or CH enter Tare Set mode Scale displays 00000 waiting for user input Press voy or Ter and Cer or D input weight Press 47 or B enter weight Indicator TARE lights on Scale must be in gross mode otherwise E Hr E displays Weight must exceed 0 otherwise Weight must be lighter than 100 F S otherwise displays Resolution Switch Press A or and then press fel switch display resolution Scale displays new resolution High resolution offers better accuracy at the
8. ght setting 6V 10Ah battery works from 80 hours to 200 hours 6V 5Ah battery works from 40 hours to 100 hours 6V 3 2Ah battery works from 30 hours to 80 hours In order to conserve battery life enable Auto Off and Idle Mode dim LED brightness or turn off LCD backlight Charging time for a completely discharged battery is Page 12 of 15 High Resolution Digital Crane Scale User Guide approximately 8 hours To obtain maximum service life battery should be stored between 20 C 4 F and 50 C 122 F Stored batteries should be recharged every three months When charging battery charging indicator being green indicates lack of power being red indicates full 9 Troubleshooting Symptom Possible Cause Suggested Solution not power on after w is discharged defective battery check battery and charge defective V V key press harder and keep pressing 2sec depressed open front panel check defective power cable power cable defective mainboard contact representative display flashes discharged battery charge battery no action taken scale is disturbed re plug power cable after key defective key contact representative pressed load in motion keep load stable change Anti Motion weak Anti Motion weight reading level not stable damped loadcell or dry loadcell or mainboard mainboard defective mainboard contact representative weigh
9. harge battery with its dedicated charger or replace it with a full one Rotate load rather than scale if needed Do NOT use scale under thunder or rain Hang scale on shelf in dry and well ventilated room Do NOT place scale on the ground directly eO 0909 BR E Do NOT attempt to repair scale yourself Contact your local representative 2 Features This scale is a combination of sound and proven mechanical design with today s most advanced electronics to provide a superb feature set It is versatile reliable accurate and easy to operate v1 Superb Quality Strictly in accordance with OIML R76 Chinese GB T11883 2002 national standards and European CE directives M Great Safety Aluminum casting case high firm hook and ring Page 1 of 15 High Resolution Digital Crane Scale User Guide dedicated weighing loadcell for safety installation v1 Strong Reliability Cutting edge technology quality integrated circuit for high performance and long time stability ivi Broad Applicability Popular and applicable in storage textile metallurgy industry and so forth v1 Easy to Use Ultra red remote controlling design Easy to operate on the scale or in distance EN Complete Function Division switch unit conversion automatic power save battery inspection idle mode tare set etc 3 Specifications Accuracy Class Chinese GB T 11883 2002 Class III Equivalent to OIML R76 Tare Range 100
10. ing range of scale For example if a 5000 2kg scale has a 1000kg container as tare the scale will overload at a new weight of 4018kg 5000 1000 additional 9 divisions In net mode press Cr Or CH tare scale out Indicator TARE lights off Scale must not be locked otherwise Mota displays Lock Unlock Press amp J or m lock scale Indicator HOLD lights on Scale must be stable otherwise Do 5E B displays Press amp J or m unlock scale Indicator HOLD lights off Accumulate Press Je accumulate current weight Co displays indicating weight is accumulated Scale uses displayed weight so gross or net weight is added into the same accumulator Scale must not be locked otherwise Mota displays Scale must be stable otherwise Do 5E B displays Weight must exceed 0 otherwise displays Scale must return zero before new weight can be accumulated otherwise oul d displays Page 7 of 15 High Resolution Digital Crane Scale User Guide SAOOL IS Gg eo GR View Press enter View mode Display flashes accumulated weight Scale must not be locked otherwise Hold displays If accumulated weight is zero mo REE displays Press Le or E to view high 5 digital and low 5 digital Press w or P exit View mode Delete Press ej delete last accumulated weight d E L displays indicating last accumulated weight is deleted Delete function only d
11. ss v or Ta and e change LED brightness LCD backlight status Press Kox or exit and save Dim LED brightness or turn off LCD backlight saves battery power dramatically LED brightness can be set to 1 dim 2 normal 3 bright s Press amp J or Lo enter Anti Motion c exit without saving Press ZA J or El Page 11 of 15 High Resolution Digital Crane Scale User Guide KI O Li Anti Motion Scale display Anti Motion level to be set e g DER indicating level 1 Press or or CR and le change Anti Motion level Press VO V or 8 exit without saving Press a or 9 exit and save At the cost of measuring time Anti Motion function intelligently settles weight reading when scale is in motion The weaker Anti Motion is the faster weight reading displays but the longer it takes to be stable Anti Motion can be set to 0 off 1 weakest 2 weak 3 normal 4 strong 5 strongest Press 8 J or yi enter Auto Off again 8 Battery Maintenance To maximize battery life please note the following battery maintenance guide This scale is powered by a 6V rechargeable lead acid battery Battery is permanently attached to battery door To remove battery pack turn off two screws on access door pull battery pack straight out and unplug battery cable from scale Depending on LED brightness or LCD backli
12. t reading discharged battery charge battery not zero when tead celt stressed too hang scalein sterage Page 13 of 15 High Resolution Digital Crane Scale User Guide no load long drifting loadcell contact representative large error in weight reading scale not zeroed before applying load manual Zero scale before loading wrong unit switch to correct unit scale requires calibration calibrate scale defective loadcell or mainboard contact representative battery can not defective charge board contact representative be recharged defective battery short remote discharged defective replace remote controlling S remote battery controller batteries distance Page 14 of 15 High Resolution Digital Crane Scale User Guide 10 Notes Page 15 of 15