Home

808 Hair Removal Product User manual

image

Contents

1. Energy Density Set 9 4 4 Double Mode Interface Beijing Moblaser Technologv Co Ltd www moblaser com Skin Type Skin type Select Pulse Width First Pulse width and Second Pulse width Adjustment Frequency Frequency Adjustment 1 10HZ Total Energy Total energy counter J Total Pulse Total pulse counter SET Set parameters Save to flash COOLING Crystal cooling Back to SDL interface READY Ready Before to Lighting STANDBY Standby Set Parameters Energy Density Energy Density Set 9 5 Emitting Laser Beijing Moblaser Technologv Co Ltd www moblaser com After you set the parameter prsess the READY button and the system will remind you to wear the laser protected glasses protect wavelength from 670nm to 1064nm then you tread down the handswitch the laser will emiting 10 Failure Detection Problem Eventually Cause Problem Solving When put on the key switch the unit does not start ant the power indicator is off 1 Emergency Stop button is pressed 2 The fuse is burned 1 Turn the Emergency Stop button back to position the normal 2 Take off the power line to cut off the power and check the fuse Alarm information on the screen 1 water supply error 2 power supply error 3 water temperature is high 1 check the water cooling system 2 check the Power Mode 3 Shutdown period of time stay the water tem
2. 7 3 Front At the front of the unit you will find 1 Emergency stop 2 Key switch 3 Hand Piece Port 4 Hand Piece 5 Color Touch Screen 7 3 1 Key Switch The key switch serves as the main system activator If the key switch is in off position the whole unit is switched off The laser unit will be delivered with two keys and cannot be operated without a key The key itself can only be removed in the off position Turning the key clockwise into the on position the laser is supplied with voltage After turning the key into on you will see an immediate information on the touch screen and the power indicator is on 11 Beijing Moblaser Technologv Co Ltd www moblaser com Only physicians been trained on the instrument should have access to the key 7 3 2 Emergency Stop The emergency stop connects with the system s power supply By pressing it the unit will be removed from the mains completely Before restarting the key switch should be turned into off position then presses the emergency stop and pulling the knob to the direction as the arrow on the knob indicates to make it back to normal condition at last turns the key switch into on position 7 3 3 Hand Piece Port The hand picec port is designed with a standard connector Be sure that the connection is in proper position The safety indicator will give warning when the hand picec is wrongly connected AN Attention Do prevent the openi
3. or have to be protected by material which is non reflective Close to the laser only non reflective or non flammable material should be present 4 4 Safety indicators At all the entrances exits and the windows from which the laser could escape the laser safety indicators should be affixed 5 Safety Tips and Technical Acceptance 5 1 General The 808nm is a precise medical laser device and can only be used for medical application The system has been thoroughly developed and will be thoroughly tested before shipment To enjoy your product through the lifetime and to protect you and your personal from laser radiation we recommend to read this chapter very carefully In addition the person to operate the unit should Beijing Moblaser Technologv Co Ltd www moblaser com get relative professional training before using it The 808nm is classified class IV Class IV describes only high energy lasers and therefore needs certain precautions before switching on the system to allow a safe and trouble free operation Additional we high recommend not to use any flammable close to the laser 5 2 Eye Protection A Attention Do not look into the laser beam or in reflected or scattered light of the laser beam Never look directly into the output of the fiber optic or the output of the laser handpiece Damages of the retina could occur To avoid any eye problems the safety goggles have to be clearly marked and seen in any room
4. the safety indicator for fiber The indicator will be on once the fiber is removed The screen will give information and the unit then will be off and the foot switch cannot control the output of the laser 5 8 Manual Reset Any improper function of the system will immediately cut the voltage supply to the laser and the complete unit is switched off To restart the unit the key has to be turned into off and then on position If the failure shows up repeatedly please contact egold or the distributor at once 5 9 Safety Signs Beijing Moblaser Technologv Co Ltd www moblaser com A Danger for laser Laser output window External interlock connector on O R Laser stop interlock fiber connector R A Beijing Moblaser Technologv Co Ltd www moblaser com B type device refer to operate manual 6 Clinic indications This system is mainly used for the treatment of hair too much of the crowd AN Warnings The unit should only be operated by a physician who has been instructed in the use of the instrument 7 Description of Instrument 7 1 General Overview The 808nm diode laser consists of five main components Laser system Color touch screen the handpiece 7 2 Housing The laser system consists of the stacked array diode laser module power supply control panel safety shutter and the embedded computer control system Beijing Moblaser Technologv Co Ltd www moblaser com
5. where the laser is installed All persons including patients have to wear safety goggles as soon as the laser is turned on Different safety goggles for corresponding wavelengths are available to protect the eyes Should you have further questions about safety goggles please get in contact with SUG or your local distributor 5 3 Electrical Protection Opening the unit service or adjustments inside the unit should only be carried out by certified person from the distributor of egold egold will not have any responsibility if any other person opens the unit without the approval of 808NM or the distributors The unit is set for the limitation of current before shipment so as to prevent the dangerous Beijing Moblaser Technologv Co Ltd www moblaser com output of the laser in a non normal condition Be sure that the unit is connected to the ground well when it is in operation The room where the laser is installed should be clean and dry As soon as the room is clean the service personal has to make sure that the laser does not see any dripping water or any vaporization of water when it is switched on AN Attention Do never attempt to work with the laser when a failure code is displaved and please get in contact with egold or the distributors 5 4 Fire Hazards AN Danger Do not work with the laser and the laser beam close to flammable anesthetic or other solvents which are easilv flammable Verv important is that pap
6. Beijing Moblaser Technologv Co Ltd www moblaser com 808 Hair Removal Product User manual Beijing Moblaser Technologv Co Ltd www moblaser com Content L Velncoyal ste A 0 a epee etter 3 Led Opyt Slt s seat ien pea e a 3 2 Theory and the technical information ss enennenzenzznnznnnnnenrnnrnnnznnrnnnznnznnzanznmrznnzzzza 3 3 Stora e Transportations Gee dees eds eds eel dle 3 stallati ss as si teste E e ste g a a 4 4 1 Transportation and installation ss nnennennznnnenzznzznzznnenrnnnznnznnznnrnnzznnzanzanznnzznazzz 4 4 2 Unpacking and inspection ss esnseennnnzannenznnznnanzannrznznnnanzannnrznztnnanzannnrrnznanmnzzz nanna 4 4 3 Requirements to the ROOM sssini n a a a 4 4 3 1 Labeling of the Entrance nnnnennennnnnnennnnnn nn nr r rr nr r rr p artna 4 4 3 2 Laser protection at WindOWS ss seeseenennzenzenzanzznnnnzanzznnznnzanzanzznnzenzanzanzzenzenzanzanzzzzzanzaa 5 4 3 3 Protection of high reflective Surface nn r re r rr n rna 5 4 4 Safety indicators ccccccccscssscssscesscesecesecesecesscesecesscssecesecesecesecesecesecesesessceaesesseessseaeseseengs 5 5 Safety Tips and Technical Acceptance sse mensnnnnnnzenzenzznznnenzaninnznznnnanznznnnzanananznznaa 5 Sul General iii ii E E E A ES 5 S DAE VE Proteco ae A E E E O E retae aneveahs eacbad cba rata tie 6 5 3 Electrical Protection iyis e e E E R R E eed 6 SA Fire Hazards A ea erie ea a a aE EE E EEE 7 5 5 Protection to S
7. cattered Li bfis ssisjrtetinzmjsjrti ojniisjiipis AA 7 X0 Main SWIC Mosse a si e i e je 8 5 7 Satety SWIt bi E E E ee ne ee E E 8 5 83 Manua CRESE i sec ccs p ae f d ta E E EE EE EEE 8 5 9 Safety SIGHS assan euen ernen ene a a RE EES naan eas 8 6 Clinic Indications oe as eneee i i a cd 10 7 Description of Instrument seise e ER aed aa eae 10 7 1 General OVerview direii nn nn aeea a ara aE AE DEEA Eei E T EAEE R oe 10 T NOUS UID etta 10 AO a aa AE Seuseeds beanben Senmeaenaeertenns 11 7 3 Key Switebiss iii ian a hee eve ee AA 11 1 32 Emer en Vv SLOP AIEI E A AET 12 1 3 9 Hand Piece POM issa iii ea A 12 1 3 4 Color TOUCH Scr en is sis iii i E E EA EEEE EA 12 TA Hand Pic Ce ee foe ta8 occ san bese cas tacesnnes E E E tutes 12 7 4 1 Specifications cccceccescescesceeecesceseeseceeeeneesecsecseeaeeaesseceeeesessesaeseeeeaeeaesaeseesesesaeeeeseneeaees 12 8 Speci Cati ONS sersem ki fe ascend r nR dete e fet pivintkzta i deeds dati ma Mann d 14 9 Operating the Instrument ii kie e b a EE span 14 9 1 TntrOduct OM isii gara es R A 14 92 Starting OE the MUM i ata ena eee ia sa a ta ai p e aee a ea Esai teniras d 17 9 3 Color Touch Screen is ne eae nese ce ene eee 15 OA Maiti MGtUG2 fice assists ti basi ss aa g a aleesecteuueeeeatee eens 15 LO Failure Detecti ni iss sisbiiinaietietu jii jeb a edisieeintisten beats 8 adadlaxs 19 IL Abandoned Productsscicccntacido ii bb kai ieli a R a ed Madewa dd ean 20 IATA 20 Beijing Moblaser Techno
8. er and plastics are removed from the laser area Focusing of the infrared wavelength or anv other wavelength onto high absorbable material can ignite those materials When the laser is not in use or patients are changed or a break in the treatment occurs the laser should be switched from ready into stand by At this mode the laser can not be activated by the hand switch 5 5 Protection to Scattered Light To prevent any triggering of the laser during connecting handpieces s the sequence of operating of the laser should be a Connect the laser handpiece b Switch the laser on Beijing Moblaser Technologv Co Ltd www moblaser com As mentioned above does not focus the laser beam onto flammable material The hand switch which triggers that laser should not be moved outside surgeons area Never trigger the laser via a third person the laser should only be triggered by the physician 5 6 Main Switch The main switch for the unit is a key switch at the front of the laser The key should only be carried or be available by the physician who operates the machine Turning the key into on position starts the electronics and the laser which after the self check is ready to be used 5 7 Safety Switch The unit will be automatically in stand by condition after starting and the laser can only be released as soon as the ready button is pressed Then the foot switch can control the output of the laser The 808NM offers
9. ion Please use the single use fiber which through the CE certification 13 Beijing Moblaser Technologv Co Ltd www moblaser com 8 Specifications temperature is 5 C 40 C relative humidity is less then 80 and atmosphericis is 860hPa 1060hPa Laser type GaAlAs diode laser Wavelength 808nm 10nm Housing stacked array diode laser Output power 600W max Operation mode Single pulse Dobule pulse Pulse Pulse width 10ms 400ms Pulse repetition rate 1Hz 10Hz Transmission system Crystal Windows Operation interface Color LCD touch screen Power supply 220Vac 15A 50Hz Laser Class 4 Safety classification IIb Cooling Distilled water FUSE T 250V 15A Waterproof level IPXI Footswitch Waterproof level IPX8 9 Operating the Instrument AN Attention The 808NM should only be operated by a physician who has instructed in the use of the instrument during installation This part of the manual only describes the technical use of the instrument without detailing the medical use 9 1 Introduction Before operating the instrument you should check following press to avoid malfunctions or problems during surgery Beijing Moblaser Technologv Co Ltd www moblaser com Is the unit connected to the mains supply If the handpiece will be in use is it connected to the Port Is the external interlock connector used Are safety goggles available for people in the room 9 2 Starting of the Unit To start the laser unit turns the key
10. logv Co Ltd www moblaser com 1 Introduction Many thanks for your using 808nm Hari Removal system 808nm high power medical diode laser system is class 4 laser Care is required to avoid hazards or injures The manual should be read very carefully before your unit will be switched on by yourself If you have further questions which are not answered by this manual regarding safety application or operating of the unit please get in touch with egold see sales and service information paragraph 12 or your local distributor 808NM high power medical diode laser system s anticipation use is surgical operations include Hair removal Delicate skin 1 1 Copyright The appearance the pulse power technology control software and other related parts are but not limit to them the parts of the 808nm s copyright with all rights to be defended Any person or company will be take legal responsibility for counterfeit The copy or the translation of the manual or the parts of the manual shall be on the approval of egold The manual will be updated with the continuous modifications and upgrade for the unit 2 Theory and the technical information Diode laser is a kind of laser with semiconductor as working material It consists of working material cavity resonator and power source The diode laser for this unit is GaAlAs diode bar and the wavelength is 808nm It features impact structure high efficiency and long lifetime Ge
11. nerally the beam shall be shamed as the big beam divergence of the laser from the diode With the egold S unique pulse power technology and ICE Colling the hair can be removal painless 3 Storage Transportation The 808NM should only be transported and stored in its original container to prevent any damage 3 Beijing Moblaser Technologv Co Ltd www moblaser com of the unit For storage of the unit the ambient air has to be dry less than 80 and clean and the temperature should ranges from 0 C to 55 C and the atmosphere should ranges from 500hPa to 1060hPa The unit should avoid any contamination of acid alkali or caustic material It should avoid the strong shine or the rain The drastic shaking during the transportation should be prohibited Also please don t throw or beat the unit 4 Installation 4 1 Transportation and installation In most of the cases the laser will be unpacked and installed by egold or one of the representatives which are responsible for the tests and inspections on the spot 4 2 Unpacking and inspection The unit is well packed before transportation Please do check carefully whether there s any damage to the package after you receive it When unpacking please check whether all the documents are inside according to the packing list see Annex1 and save them with care for them will be in demand when you return the unit to egold or keep the unit Please contact immediately egold or authori
12. ng from the contamination of dust liquid oil or any other material Or the output power of the laser will be decreased even the inner laser system will be damaged Do not remove the hand piece when the unit is operated 7 3 4 Color touch Screen The crystal touch screen is the man machine interface All the operations to specifications system control and unit conditions are done by the touch screen A Attention Do not touch the screen with any sharp materials in case there s any scratch to the surface Cautions have to be taken that the liquid cannot sprinkle on the surface of the touch screen 7 3 5 Laser output indicator The laser output indicator will be on when any laser releases The indicator s action synchronizes with the laser The laser output indicator will be on if the system is in an emergent or a non normal status At that time the system will be shut off all the output and the information for the problem will be displayed on the touch screen Beijing Moblaser Technologv Co Ltd AN Attention Please press the emergency stop to shut off the unit if the laser output indicator is keeping on 7 4 Handpiece 7 4 1 Specifications Handpiece has 10 bars each Bar power of 50W Crystal Area is 12 12mm 7 4 2 Cleaning The handpiece will contact the patients directly Before using them clean with alcohol for at least 2 minutes Please conform to the requirements of the specific operation AN Attent
13. perature decreases 11 Abandoned Product The abandoned machine should be properly deal with comply with the local Law 12 Service lt Quick response within 24 hours and the spare accessories and equipments available at any time lt Regular maintenance and technique support on the spot Beijing Moblaser Technology Co Ltd Add NO 118 Jianguomenwai Street Chaoyang District Beijing 100020 CN Tel 86 10 59753205 Web www moblaser com Beijing Moblaser Technologv Co Ltd www moblaser com Annexl Packing List Nos Item Description Qty 1 808NM Diode Laser Svstem l 2 Hand Piece l 3 Kev 2 4 Protective goggles l 5 Filter cartridge 2 6 Power Supple Cable l T Operator s manual l 8 Warranty Card l 9 Inspection Report l 10 Packing List 20
14. switch clockwise into on position You immediately can hear that the fans are working and the crystal screen does lid up with the word 808NM as seen Afterwards the screen shows the information as Initialling Then a system self check will be performed If a problem occurs the machine will inform you at the display about the problems At this time please check chapter 10 Problem solving see diagram below System needs 15 seconds to setup 9 3 Color Touch Screen The unit offers the crystal touch screen with high sensitivity and resolution served as operating window With finger or professional pen to touch the relative buttons shown on the screen you will set kinds of specification working modes and machine status The interface is easily operated for its terse design and obvious layers 9 4 Main Menu 9 4 1 Boot Interface Beijing Moblaser Technologv Co Ltd HAHMH oe 9 4 2 Mode Select Interface HAIR REMOVAL LASER MODE SELECT Beijing Moblaser Technologv Co Ltd www moblaser com CINIT OC OINI CE MARL Skin Type Pulse Width Frequency Total Energy Total Pulse SET COOLING READY STANDBY Energy Density Skin type Select Pulse width Adjustment Frequency Adjustment 1 10HZ Total energy counter J Total pulse counter Set parameters Save to flash Crystal cooling Back to SDL interface Ready Before to Lighting Standby Set Parameters
15. zed distributor 4 3 Requirements to the Room In addition to the indicators warning logos on the unit it is required that when a laser of class IV is used the entrances to the room have to be marked 4 3 1 Labeling of the Entrance Each entrance door has to be marked clearly so that from the outside the laser room can be recognized immediately Beijing Moblaser Technologv Co Ltd www moblaser com gt At each door the laser warning logo has to be affixed In addition to this the wavelength of the laser has to be marked on this logo gt Each entrance door has to be equipped with a warning light Every time the laser is switched on the warning light has to come on and be illuminated to the outside This should prohibit any people to enter the room when the laser is in use 4 3 2 Laser protection at windows It is important that no laser light during treatment can escape from the room Windows or any other openings to the outside have to be secured with proper material to avoid laser beams escaping from the room If you need information or help in designing the room please get in touch with egold or your local distributor 4 3 3 Protection of high reflective Surface To avoid any direct or indirect scattered radiation from the laser beam no high reflective material should be in the treatment room Thus could be mirrors pictures behind glass covers high polished chromium surfaces and windows Those surfaces have to be removed