Home

InSight Adapter Technical Specification

image

Contents

1. e Support for 10 100 Ethernet protocols TCP IP and UDP via an RJ 45 connector e Auto Rate negotiation for either 10 or 100Mbps Ethernet e Auto MDIX detection and switching allowing use of both normal and crossed RJ 45 cables Insight Adapter Technical Specification TS1 Rev 0 9 Page 3 e Access to the EM250 UART TTL compatible via the InSight Data Emulation Interface e InSight Port signals individually buffered for RCM operation down to 2 1V e USB support for administration and configuration e InSight Adapter reset button e Fully enclosed to ease deployment e Cables included with InSight Adapter e InSight Port cable e USB cable e InSight data emulation cables InSight Adapter Enclosure The InSight Adapter PCB enclosure is secured on the bottom by two screws You can deploy the adapter in any convenient orientation on a benchtop or throughout the application environment Do not open the enclosure If you experience issues or problems with the adapter contact Customer Support at www silabs com zigbee support Table 1 lists the interfaces and mechanical characteristics of the InSight Adapter Insight Adapter Technical Specification TS1 Rev 0 9 Page 4 Supplying Power to the InSight Adapter Table 1 Mechanical characteristics of the InSight Adapter Parameter Description Dimensions Enclosure 5 2 x 5 1 x 1 5 I x w xh Front panel 4 7 x 1 3 Rear panel 4 7 x 1 3 I
2. red and orange LEDs are reversed Voltage Selection Toggle Switch Because the EM2xx family can operate with a supply voltage between 2 1 and 3 6V and the core logic of the InSight Adapter is at either 1 8V or 3 0V the InSight Adapter must be able to properly buffer the signals between the EM2xx and itself In addition the InSight Adapter can supply power to the EM2xx through the InSight Port Insight Adapter Technical Specification TS1 Rev 0 9 Page 10 Therefore the InSight Adapter contains digital control logic for the InSight Port voltage buffers based on the position of the three position voltage selection toggle switch Table 5 describes the toggle switch positions Table 5 Voltage selection toggle switch positions Toggle switch position Description eS nt The InSight Port enables current draw from the InSight Adapter i power management block This is at 3V and sources as much as 50 mA Ext Of Int The InSight Port is disabled This is the default shipping E position EAS Orn The EM2xx based hardware contains its own power supply such as a battery source and the InSight Port signals are buffered to that voltage level Note The InSight Port Voltage Selection Logic requires 5 mA max of current from the external power supply InSight Adapter Reset Button By depressing the InSight Adapter reset button the InSight Ad
3. Technical Specification Insight Adapter Technical Specification TS1 Rev 0 9 Page 9 LED Indicators Front Panel Four LEDs on the front panel indicate the operational state of the InSight Adapter Table 4 describes the LED states Table 4 InSight Adapter LED indicator states 1 LED states Description All LEDs illuminated Power on sequence of InSight Adapter initiated Only orange LED illuminated bootloader initiated with default configuration Green LED illuminated with blinking red LED InSight Adapter application has begun Green with OS Heartbeat Red Note This is the normal operating state of the InSight Adapter At this point it is safe to use with the InSight Desktop Green and Red LEDs illuminated with blinking Yellow LED the InSight Adapter booted up in default configuration mode because both the config txt and config bak configuration files are corrupt Green and Yellow LED illuminated with blinking red LED InSight Adapter is in Upload mode Red LED stays illuminated for a period of time gt 30s InSight Adapter Firmware is corrupt Power cycle the InSight Adapter If this persists contact Customer Support Green LED stays illuminated InSight Adapter is unsuccessfully trying to get an IP address from a DHCP Server 1 On ISAs built before 4 30 2006
4. the EM250 Development Kit User Guide LED Power Indicator The blue LED on the back panel illuminates when valid power is connected to the InSight Adapter This LED should stay lit but not blinking during normal operation If the LED blinks disconnect power and contact Customer Support at www silabs com zigbee support Front Panel Interfaces The front panel shown in Figure 1 contains two data interfaces a voltage selector switch a reset button and four LEDs The two data interfaces include the InSight Data Emulation Interface labeled Debug Port in Figure 1 and the InSight Port The voltage selector switch enables appropriate buffering on the InSight Port cable The four LEDs indicate the operation state of the InSight Adapter InSight Port The 10 pin dual row 0 05 inch pitch InSight Port is the programming and debug interface for the EM2xx family of chips It contains the four SIF Signals SIF_MOSI SIF_MISO SIF_LOADB and SIF_CLK two Packet Trace signals PTI_LEN and PTI_DATA and voltage and ground connections An InSight Port cable is shipped with the InSight Adapter With the InSight Port Samtec P N FFSD 05 D 12 00 01 N direct connection to the EM2xx based design either the Ember RCM or customer designed module is available When the InSight Port cable is attached full access to the features of InSight Desktop is available Note Any design involving an Ember EM2xx chip should route the InSight Port sig
5. SILICON LABS March 10 2013 TS1 Rev 0 9 Silicon Laboratories Inc 400 West Cesar Chavez Austin TX 78701 Tel 1 512 416 8500 Fax 1 512 416 9669 Toll Free 1 877 444 3032 www silabs com InSight Adapter Technical Specification The Ember InSight Adapter is the hardware interface between the Ember EM2xx based designs and the Ember InSight Desktop This document describes InSight Adapter features and specifications New in this Revision Document renumbering Contents OVENVIOW sesisieins aisisicig ais aicias Sea ean AROK Seba cebe EE EEE RAES FQAtUROS 5 iccsisvs sensi ssvesinsseaescvenabves suse sass cassinda sabe cadssnwedeeestiew geen sew eases twessnen Supplying Power to the InSight Adapter cccccccescceeneeeeneeeeneeeeseeeeseseesseees Setting Up the InSight Adapter cece cece cece cence eeenee ence eesceteneeeeeeeesneeeeseeees Mtera ceS ooie aS ANCE OESE nd cans tereaaeed cxaecn Segue amostensenmnasnaserses Page 2 Overview Features The InSight Adapter provides the programming debugging and data emulation capability for EmberZNet PRO based applications It converts between the Ember SIF commands Packet Trace Interface TCP IP and UDP for an easy to deploy system over 10 100 Ethernet It also contains power management logic to transform Power over Ethernet PoE into IC friendly voltage planes So you can integrate the EM2xx based debugging environment into an existing netwo
6. apter jumps into its reset state machine After Reading This If you have questions about the information described in this document please contact Document Customer Support at www silabs com zigbee support Insight Adapter Technical Specification TS1 Rev 0 9 SILICON LABS The information in this document is believed to be accurate in all respects at the time of publication but is subject to change without notice Silicon Laboratories assumes no responsibility for errors and omissions and disclaims responsibility for any consequences resulting from the use of information included herein Additionally Silicon Laboratories assumes no responsibility for the functioning of undescribed features or parameters Silicon Laboratories reserves the right to make changes without further notice Silicon Laboratories makes no warranty representation or guarantee regarding the suitability of its products for any particular purpose nor does Silicon Laboratories assume any liability arising out of the application or use of any product or circuit and specifically disclaims any and all liability including without limitation consequential or incidental damages Silicon Laboratories products are not designed intended or authorized for use in applications intended to support or sustain life or for any other application in which the failure of the Silicon Laboratories product could create a situation where personal injury or death may occur Should Bu
7. ar which Silicon Labs has tested and determined performs satisfactorily If you plan to use a different PoE injector contact Customer Support at www silabs com zigbee support before connecting Note Power over Ethernet is disabled when the InSight Adapter is powered with the 12V DC power input However the Ethernet data is still available Insight Adapter Technical Specification TS1 Rev 0 9 Page 5 Table 2 describes the electrical characteristics of the InSight Adapter Table 2 DC electrical characteristics of the InSight Adapter Parameter Min Typ Max Unit 12V DC power jack Voltage supply 7 12 25 V Current draw 12V 120 mA Power over Ethernet Power rating 1 44 W InSight Port current source 40 50 mA to RCM or EM2xx based design Temperature range 40 85 C Setting Up the InSight The Ember Development Kit supports the InSight network which runs over the Adapter Ethernet Each Ember node is connected to the InSight network via its InSight adapter which also takes node activity accessible to InSight Desktop Together InSight adapters and InSight Desktop provide an integrated development environment where you can perform a number of tasks including e Debug hardware e Monitor application or debug data e Monitor radio data packets Note The Ember Development Kit is configured to support DHCP If your site is configured for static IP addresses refer to doc
8. er supply with appropriate AC plugs for your region while the EM2xx Kit ships with a Power over Ethernet injector Note PoE and a DC power supply can be connected to the InSight Adapter at the same time Logic in the InSight Adapter gives priority to the DC power supply Insight Adapter Technical Specification TS1 Rev 0 9 Page 7 DC Power Jack The DC power jack on the InSight Adapter allows for a robust connection 5000 cycles to the 12V DC power supply provided The 2 1 x 5 5mm jack from CUI Inc MFG P N PJ 105A SMT is rated to 16V DC at 2 5A The center pin of the jack is V with shroud connected to the GND plane If you want to use a different DC power supply contact Customer Support at www silabs com zigbee support RJ 45 Connector The RJ 45 is a 10 pin surface mount interface for a standard Cat5 cable It provides access to the Ethernet backchannel via 10 100 Ethernet link The connector also provides for a 48V interface from the Ember Development Kit s Power over Ethernet injector The connector on the InSight Adapter integrates the Link and Activity LEDs for an immediate feedback for proper installation USB The USB connector USB B type is used only for administration and configuration of the InSight Adapter A standard 4 foot USB cable USB B to USB A ships with the InSight Adapter however you can use any USB cable For more information on configuration and administration commands refer to document UG108
9. nals to test pins or ideally to a dual row 0 05 inch pitch SMT footprint similar to the Samtec MFG P N FTSH 105 01 F DV K Insight Adapter Technical Specification TS1 Rev 0 9 Page 8 Figure 3 illustrates the InSight Port connector and Table 3 describes the pins on the InSight Port Figure 3 InSight Port connector Table 3 InSight Port pins Pin Signal name Direction Description 1 VBRD Power 2 1 to 3 6V supply for the RCM SIF_MISO Output Serial Interface master in slave out 3 SDBG Output Debug signal to be used on future pin compatible products 4 SIF_MOSI Input Serial Interface master out slave in 5 GND Power Ground 6 SIF_CLK Input Serial Interface clock 7 nSIF_LOAD V0 Serial Interface load strobe open collector with internal pull up 8 nRESET Input Active low EM250 Reset Signal internal pull up on EM250 I 9 PTI_EN Output Packet Trace enable signal 10 PTI_DATA Output Packet Trace data signal 500 kbps InSight Data Emulation Interface The 26 pin dual row Extended Debug Connector allows additional access to the EM2xx series of chips On the EM250 it allows access from the backchannel port 4901 to the EM250 UART connection on the EM250 Breakout Board The DEI cable is custom to the Ember InSight Adapter and is provided as part of the InSight Adapter assembly For more information on the EM250 Breakout Board refer to document TS3 EM250 Breakout Board
10. nterfaces InSight Data Emulation Interface 26 pin dual row stress release connector InSight Port 10 pin dual row 0 05 pitch RJ 45 for PoE and 10 100 10 pin 802 3af standard connector USB USB B Type Connector for serial administration 2 1 x 5 5mm Center Pin Connector Push button Normally Open 12V DC power jack InSight reset Back panel LED Power indicator Blue LED Front panel LEDs left to right Green Red Yellow Orange 1 On ISAs built before 4 30 2006 red and orange LEDs are reversed Warning The Power over Ethernet circuitry within the InSight Adapter carrier board operates at a 48V DC potential Before connecting Power over Ethernet follow the basic electrical safety instructions provided in the NetGear User Manual As shown in Figure 1 you can power the InSight Adapter with either e 12V power input DC power jack e RJ 45 connector using Power over Ethernet IEEE standard 802 3af 2003 defines Power over Ethernet This standard recommends that power and data be delivered to a device via a standard Ethernet Cat5 cable eliminating the need for an electrical cable in addition to a data cable When a device is not drawing power from the Ethernet cable the power sourcing equipment turns off power to that device You must have a power injector in order to power the board with the Ethernet cable Silicon Labs recommends the power injector supplied in the Developer and Jump Start Kits from NetGe
11. rk infrastructure and remotely deploy hardware during the development phase without having to stay close to a wall outlet However a DC power jack is also available for applications that need it As part of the Ember Development Kit the InSight Adapter connects to the EM250 RCM through two interfaces the 10 pin InSight Port and the Insight Data Emulation Interface These two interfaces provide access to all EM250 GPIO as well as the EM250 programming and debug 1 0 Six different services are available within the InSight Adapter over Ethernet These include e Backchannel debug service e Discovery service e SIF service e Time Sync service e Packet Trace service e Administration service Therefore the InSight Adapter contains the same functionality as the previous Ember product family With InSight Desktop and the InSight Adapter an EM2xx based network integrates into an existing EM2420 based network For more information on the different services and IP ports supported by the InSight Adapter refer to document UG108 the EM250 Development Kit User Guide See document TS2 the EM250 Radio Communication Module Technical Specification for more information on the RCM The Ember InSight Adapter offers e Programming and debugging of the Ember EM2xx chip family e Programming speed up to 25MHz over a 1 foot InSight Port cable e Power over Ethernet conversion no power supply needed e One DC power jack for applications not using PoE
12. ument UG108 the EM250 Development Kit User Guide about configuring nodes for static IP addresses To set up an InSight environment 1 Connect the supplied Ethernet switch so it has access to a DHCP server 2 Connect to the Ethernet switch router e All InSight adapters e The workstation where InSight Desktop is installed 3 Identify the RCM that is labeled Sink connect it to the InSight adapter that is labeled ember00 4 Connect the remaining RCMs and InSight adapters Insight Adapter Technical Specification TS1 Rev 0 9 Page 6 Interfaces 5 Connect each RCM to the EM250 Module area of a breakout board 6 Connect the remaining RCMs to breakout boards 7 Verify that each RCM powers up by checking whether its red LED is on If not check the RCM Power Select switch on its InSight adapter and verify it is set to Int as shown in Table 5 Figure 1 and Figure 2 show the interfaces on the front and back panels of the InSight Adapter Figure 1 InSight Adapter front panel 00 0d 6f 12 34 56 Figure 2 InSight Adapter back panel Back Panel Interfaces Figure 2 contains three PC based interfaces a USB connector an RJ 45 connector and a DC power jack and one LED indicator The LED indicator blue illuminates when valid power is connected to the InSight Adapter The InSight Adapter can be powered either by the 12V DC jack J3 or by Power over Ethernet Therefore the InSight Adapter ships with a 12V DC pow
13. yer purchase or use Silicon Laboratories products for any such unintended or unauthorized application Buyer shall indemnify and hold Silicon Laboratories harmless against all claims and damages Silicon Laboratories Silicon Labs and Ember are trademarks of Silicon Laboratories Inc Other products or brandnames mentioned herein are trademarks or registered trademarks of their respective holders