Home
ADEL user manual 5600MF12S_Combined
Contents
1. Please input the available group number 3 5 2 Enrollment Change of user password The lock beeps with Input master password to enter the green indicator light enrollment mode flashing 15 Input the group number 01 29 and The lock beeps then press as 123 and then press to confirm It sounds with green will be unnecessary to press to indicator light confirm if the user number is 8 SE flashing Enrollment of user password Green indicator light successfully completed Continue to enroll other electronic keys Green indicator light 66 399 or press three times to exit NOTE Repeat the step 2 4 to continue to enroll other user passwords 3 5 3 Enrollment Change of temporary password The lock beeps with Input master password to enter the green indicator light enrollment mode flashing Input the group number 30 and then The lock beeps press Input the user number 1 8 digits such The lock beeps two as 123 and then press to confirm It sounds with green will be unnecessary to press to indicator light confirm if the user number is 8 digit flashing Enrollment of temporary password is Green indicator light nee vinh Continue to enroll other electronic keys Green indicator light D or press three times to exit oan n ng NOTE The enrolled temporary password can only be used once It s req
2. 3 1 2 7 Low voltage red indicator light flashes with alarms heard when unlocking 3 1 2 8 Mifare card has already been enrolled the lock will beep two sounds with red indicator light flashing when putting the card close to sensor area to unlock the door 3 1 3 Technical terms 3 1 3 1 Electronic key ADEL Mifare card or password 3 1 3 2 Legal valid to use after enrollment 3 1 4 Check before using 3 1 4 1 Batteries are installed 11 sasana AIEL 747 5600MFI2S C31sets Operation Instruction 3 1 4 2 All screws are tightened 3 1 5 Operating tools 3 1 5 1 Hex wrench is required to use mechanical key or change batteries 3 2 Assignment of Mifare card and password Master 1 set Group number 00 enrolling Mifare card password amp password and unlocking User mm Group number 01 29 unlocking password Temporary 1 set Group number 30 can only be used once se password for unlocking Mifare d 62pcs Group number 31 92 unlocking car There are 93 electronic keys 1n all and each electronic key can be used to unlock the door Each electronic key consists of group number and user number or ADEL Mifare card Password Group number User number 1 8 digits or ADEL Mifare 2 digits card Group number identification number of electronic key There are 93 group numbers 00 01 91 92 in all and each group number matches one set of user number The respective group number of mas
3. nh th c Thanh to n Ngay sau khi hai b n giao nh n h ng ho v ch ng t k m theo Gi i Thi u v Vken Vken Chuy n cung c p C c gi i ph p an ninh gi m s t ki m so t ra v o qu n l nh n s h th ng ki m so t ra v o t a nh kh a c a v n tay cho c c c ng tr nh to nh d n l n VKEN Company lu n m b o cung c p n kh ch h ng c c s n ph m ch nh h ng v i ch t l ng t t nh t p ng n n t ng c ng ngh m i v i gi c ph i ch ng nh t M i ch ti t v b o gi n y Qu kh ch vui l ng li n h Ph ng Kinh Doanh Hotline 0904 954 981
4. or press three times to exit Method two Remove the cylinder cover with The lock beeps with cylinder cover opener and insert the green indicator light mechanical key into the cylinder Turn flashing 14 zo ADEL 747 5600MEI2S 3 sets TT ADEL747 5600MEFI2S 31sets Operation Instruction the mechanical key 90 in the opposite direction of turning the latches back into the mortise to enter the enrollment mode Input the group number 00 and then The lock beeps press Input the user number 1 8 digits such The lock beeps two as 123 and then press to confirm It sounds with green will be unnecessary to press to indicator light confirm if the user number 1s Ges flashing Enrollment of master password Green indicator light successfully completed Continue to enroll other electronic keys Green indicator light or press three times to exit NOTE The default password or the enrolled master password will be invalid after enrolling the master password with the above methods All the Mifare cards must be enrolled before using If the cards for enrollment have already been enrolled or are not ADEL Mifare cards the lock will beep with red indicator light on Ifthe group number of Mifare card has already been occupied the lock will beep two sounds with red indicator light flashing when the group number input The lock will be back to the enrollment mode
5. deletion mode password is not master 2 Review the password instructions or contact 2 Operation steps are the after sales service incorrect 23 sasana AIEL 747 5600MFI2S C31sets Operation Instruction V After sales Service 5 1 Warranty Policy 1 Users should keep this warranty card and standard sales voucher of State Administration of Taxation opened by dealer which will be required to show as a warranty basis for maintenance Please keep the warranty card well If it s lost we will not reissue a new one 2 Warranty period starts from the date of valid purchasing voucher 3 Products including mechanical parts and electronic parts will be maintained for free within one year During this year if electronic parts and mechanical parts of the lock appear quality problems all of them will be maintained for free However damage caused by human factor is not in the warranty range Users must pay for maintenance 4 Lifelong maintenance Cost will be charged for maintenance after one year ADEL Company will provide high quality and inexpensive spare parts for each maintenance center and user 5 ADEL Company and each maintenance center provide maintenance standards technical consultation and support and business training 6 For user s letters customer service center will respond in 1 2 days for user s complaints response will be carried out on that day or the next day 7 Site service cannot be provided in some
6. disassemble the lock and batteries if installed and load batteries at the same time then a long beep will be heard after 5 seconds the initialization of the lock 1s successfully completed The lock will be restored to the factory default setting the default password of unlocking 1s 00123 and any ADEL 13 sasana AIEL 747 5600MFI2S C31sets Operation Instruction Mifare card can unlock the door 3 2 Input master password and group number of master password 00 and then press a long beep will be heard which indicates the initialization of the lock is successfully completed The lock will be restored to the factory default setting The default password for unlocking 1s 00123 and any ADEL Mifare card can unlock the door 3 5 Enrollment of electronic key 3 5 1 Enrollment Change of master password There are two methods to enroll or change master password Method one The lock beeps with Input 00123 to enter the enrollment green indicator light mode flashing Input the group number 00 and then The lock beeps press Input the user number 1 8 digits such The lock beeps two as 123 and then press to confirm It sounds with green will be unnecessary to press to indicator light confirm if the user number is 8 digit flashing Enrollment of master password Green indicator light successfully completed ee Continue to enroll other electronic keys
7. regions Service regions that are excluded by ADEL Company include the regions that have geographical barriers undeveloped roads or public transport which 1s not suitable for regular travel Maintenance service needs to negotiate and be provided through additional charges 8 Maintained parts continue to have warranty service during the warranty period If the warranty period is less than three months spare parts only have three months for maintenance since the date of replacement 24 8 oner ADEL747 5600MEI2S 3lsets Operation Instruction 9 Spare parts replaced belong to ADEL Company 5 2 Exceptional Cases In order to protect your legal rights please avoid damaging the lock unnecessarily If the lock fails to work work abnormally or is damaged due to the following reasons ADEL Company assumes no obligation for free warranty 1 2s EP 6 Your lock beyond warranty period No warranty card and standard sales voucher of State Administration of Taxation You don t install or use the lock and peripheral equipments according to manual requirements Your lock is not installed modified or disassembled by authorized service personnel of ADEL Various problems caused by the reasons including but not limited to broken door distortion of the door caused by wetness or dryness power supply issue improper product storage product bump no preventive maintenance required or using components or parts of ancilla
8. restored to the factory default setting The default password for nar waman AI EL747 5600MFI2S 3l1sets Operation Instruction unlocking 1s 00123 and any ADEL Mifare card can unlock the door 4 Enrollment of electronic key 4 1 Enrollment of master password Method one Input 00123 to enter the enrollment mode gt The lock beeps with green indicator light flashing gt Input the group number 00 and then press gt The lock beeps Input the user number 1 8 digits such as 123 and then press to confirm It will be unnecessary to press to confirm if the user number is 8 digit gt The lock beeps two sounds with green indicator light flashing which indicates the enrollment of master password is successfully completed gt Continue to 66 399 enroll other electronic keys or press three times to exit Method two Remove the front handle with hex wrench and insert the mechanical key into the cylinder Turn the mechanical key 90 in the opposite direction of turning the latches back into the mortise to enter the enrollment mode gt The lock beeps with green indicator light flashing gt Input the group number 00 and then press gt The lock beeps gt Input the user number 1 8 digits such as 123 and then press to confirm It will be unnecessary to press to confirm if the user number is 8 digit gt The lock beeps two sounds with green indicator light flashing whi
9. service amp Technical support 25 EK Leil 791 E ee eer ae renner eae e 26 EE 29 I Group number and its corresponding ADLE Mifare card 29 MA a Woot MS 0 sch case aken Ga aa aaa AB T aa a a a ka E aii 30 8 II Reference to Product Standard and Enterprise Standard 32 HI Lock Configuration Standards cccccccssscceesssecceessseeeeesseees 32 IV Handle Orientation Change 7 5555 lt lt lt ss sss2 32 V Assembly of Lock ConnecfOrs 5 5 lt s lt lt ss lt ss2 32 VE Waranty EC d 7m EA 32 s s seseE AIDEL 747 5600MFI2S 31sets Operation Instruction Note A new lock that is just out of factory or initialized can be unlocked with any ADEL Mifare card and the default password for opening is 00123 If the lock works under insufficient voltage it will beep alarms with red indicator light flashing when unlocking It is highly recommended to change the batteries as soon as possible Please use four 1 5V alkaline batteries with the same brand It may cause damage to the lock if mixing new batteries with the old ones or using non alkaline batteries Do not clean the lock surface with corrosive substance or else the protection layer may be damaged and thus influence the gloss of the lock surface Please clean the lock surface periodically with furniture polish wax If it fails to unlock the door with electronic keys please use the mechan
10. with green indicator light flashing gt Input the group number to be deleted such as 01 and then press gt The lock beeps three sounds which indicates the deletion of password or ADEL Mifare card is successfully completed gt 66399 Continue to delete other electronic keys or press three times to exit NOTE The lock will be restored to the factory default setting after deleting the master password All the enrolled user passwords or Mifare cards set by the master password will be invalid The default password of unlocking is 00123 and any ADEL Mifare card can unlock the door 4 6 Unlocking After the valid ADEL Mifare card used or the correct password input the green indicator light goes on and the lock beeps with a motor rolling sound turn the handle to open the door nar waman AI EL747 5600MFI2S 3l1sets Operation Instruction 4 7 Passage mode Press and hold button 0 within 5 seconds after the door unlocked by valid password or ADEL Mifare card the passage mode 1s set Green indicator light will flash every 5 seconds To cancel the passage mode please use the enrolled ADEL Mifare card or input the correct password to unlock the door or extend the deadbolt The red indicator light flashes and the lock beeps with a motor rolling sound which indicates the cancellation of passage mode 1s successfully completed NOTE Passage mode is specially designed for office meetings gatherings etc Wh
11. 747 5600MF12S 31sets Operation Instruction 1 Assignment of Mifare card and password Maximum 31 sets of password and 62 Mifare cards are authorized to be enrolled for the lock Electronic key Group number User number 1 8 digits or ADEL Mifare card The respective group number of master password user password and temporary password are 00 01 29 and 30 The group number of Mifare cards for unlocking 1s 31 92 Each group number matches one user number or one ADEL Mifare card 2 Anew lock in factory mode Default setting password 00123 or any Mifare card is valid for unlocking The lock makes three beep sounds and a motor rolling sound with green and red indicator light flashing in the unlocking status 3 Initialization 3 1 Please use a hex wrench to press the button which 1s on the back side of the front lock body before installation Please disassemble the lock and batteries if installed and load batteries at the same time then a long beep will be heard after 5 seconds the initialization of the lock 1s successfully completed The lock will be restored to the factory default setting the default password of unlocking 1s 00123 and any ADEL Mifare card can unlock the door 3 2 Input master password and group number of master password 00 and then press a long beep will be heard which indicates the initialization of the lock 1s successfully completed The lock will be
12. after finishing maintenance If the fault cannot be completely eliminated you can refuse to sign the Service Activity Reporting 6 Please sign on the Service Activity Reporting and propose valuable advice if the lock runs normally Official seal will be required 1f you re a company user 5 4 Feedback 1 If you are interrogative or unsatisfied with our product and service including product quality technology charge standard etc please report to local customer service center they will properly handle your feedback 2 If the local customer service center cannot solve your problem or you are not satisfied with the results please call fax ADEL customer service center headquartered in Shenzhen we will respond promptly and give you a reasonable reply 3 Contact information of various customer service centers In order for 26 you to accurately find our customer service centers please visit our website www adellock com to search 4 Contact information of ADEL Company Shenzhen Ideal Microelectronics Co Ltd Address Bldg 4 Xili Nangang Second Industrial Park Songbai Road Nanshan District Shenzhen China Tel 86 755 2765 7755 Fax 86 755 2765 2282 Email service adellock com Website www adellock com ADEL Asia Ltd Address Unit 2006 2007A 20 F Futura Plaza 111 113How Ming Street Kwun Tong Kowloon Hong Kong Tel 852 2989 6328 Fax 852 2989 6329 Email info adelfingerprint com Web
13. ay cause damage to the lock if mixing new batteries with the old ones or using non alkaline batteries 5 Check whether the screws and handle are loose or not periodically 4 2 Troubleshooting electronic key Apply legal gei be illegal electronic ma Unlock the door Apply a legal with electronic keys The electronic key electronic key or enroll red light on the lock an have been the electronic key with beeps but fails to cleared master electronic key open the door Password might be Input the correct wrongly input password Change the batteries or Unlock the door Insufficient voltage with electronic keys 5 use external power Bad contact of battery green light on ms cable and PCB cable Reconnect the cables lock beeps but fails Bad contact of motor Reconnect the motor to open the door plug and PCB slot plug with PCB slot No response when NU 22 sasana ADEL747 5600MF12S C31sets Operation Instruction a mechanical key and load the batteries unlocking the door Batteries are wrongly Reload the batteries with electronic keys loaded correctly Battery cable fails to connect PCB cable Reconnect the cables The lock beeps two sounds with red indicator light Insufficient voltage Change the batteries flashing when unlocking the door with electronic keys Fail to enter the 1 Input incorrect 1 Apply the correct enrollment mode or master password or the master password
14. cal parameters Storage humidity 10 98 RH Working humidity RH 45 85 1 DO NOT expose the lock to high radiation magnetic field humidity to avoid influencing the performance and service life of the lock 2 Keep the lock away from corrosive substances or else the protection layer of the lock surface may be damaged 1 3 3 Weight Weight of each lock with foam box About 2 3KG Weight of each carton with 6 locks included About 14 7KG ADEL ADEL747 5600MF12S 31sets Operation Instruction II Installation 2 1 Recommendation It s highly recommended to have the lock installed by professional technicians 2 2 Installation requirement 2 2 1 Opening mode D RH Right Hand Standing outside the hinges are on the right opening the door by pushing inside 2 LH Left Hand Standing outside the hinges are on the left opening the door by pushing inside RHR Right Hand Reverse Standing outside the hinges are on the right opening the door by pulling outside 4 LHR Left Hand Reverse Standing outside the hinges are on the left opening the door by pulling outside EES OF xo SOTO x gt rat 2 3 LS lt NR Re SOROS b Sa SSSR ID So ee eet dee RSI S NEE Dee GER KO NEE e x RE lt x RNS Note Default opening method in this manual is 2 2 2 Door requirement 1 Door material wood 2 Door thickness 38mm 75mm 3 If there 1s any decorative border on the door surface it m
15. ch indicates the enrollment of master password is successfully completed 66399 gt Continue to enroll other electronic keys or press three times to exit NOTE The default password or the enrolled master password will be invalid after enrolling the master password with the above methods All the Mifare cards must be enrolled before using If the cards for enrollment have already been enrolled or are not ADEL Mifare cards the lock will beep with red indicator light on 4 2 Enrollment Change of user password Input master password to enter the enrollment mode gt The lock beeps with green indicator light flashing gt Input the group number 01 29 and then press gt The lock beeps gt Input the user number 1 8 digits such as 123 and then press to confirm It will be unnecessary to press to confirm if the user number is 8 digit gt The lock beeps two sounds with green indicator light flashing which indicates the enrollment of user password is successfully completed gt 66 3699 Continue to enroll other electronic keys or press three times to exit 4 3 Enrollment Change of temporary password Input master password to enter the enrollment mode gt The lock beeps with green indicator light flashing gt Input the group number 30 and then press gt The lock beeps gt Input the user number 1 8 digits such as 123 and then press to confirm It will b
16. e unnecessary to press to confirm if the user number is 8 digit gt The lock beeps two sounds with green indicator light flashing which indicates the enrollment of temporary password is successfully completed gt Continue to enroll other electronic keys or press three times to exit NOTE The enrolled temporary password can only be used once It s required to enroll again once used 4 4 Enrollment of ADEL Mifare card Input master password to enter the enrollment mode gt The lock beeps with green indicator light flashing gt Input the group number 31 92 and then press gt Green indicator light is on with red indicator light flashing gt Put an ADEL Mifare card close to the sensor area of the lock gt The lock beeps two sounds and red indicator light is off which indicates the enrollment of ADEL Mifare card is successfully completed gt Continue to enroll other electronic keys or press three times to exit NOTE If the cards for enrollment have already been enrolled or are not ADEL Mifare cards the lock will beep with red indicator light on If the group number of Mifare card has already been occupied the lock will beep two sounds with red indicator light flashing when the group number input The lock will be back to the enrollment mode Please input the available group number 4 5 Deletion of electronic key Input master password gt The lock beeps
17. e factory default setting after deleting the master password The default password for unlocking is 00123 and any ADEL Mifare card can unlock the door 3 7 Daily use 3 7 1 Unlocking 3 7 1 1 Unlock the door with ADEL Mifare card Operational procedure Lock indication Put an enrolled ADEL Mifare The lock beeps with a motor card close to the sensor area rolling sound heard Otherwise it will be automatically locked 5 seconds later 3 7 1 2 Unlock the door with password The lock beeps with a motor 1 Input the correct password rolling sound heard automatically locked 5 seconds later Otherwise it will be j Turn the handle to open the Keypad will be locked for 5 seconds if inputting an incorrect password three times Password must be more than 4 digits 18 sasana AIEL 747 5600MFI2S C31sets Operation Instruction including Do not press any keypad within the 5 seconds otherwise the locking time will be automatically delayed for 5 seconds again The enrolled ADEL Mifare card is available to unlock the door when the keypad is locked however the locking time will be automatically delayed for 5 seconds again 3 7 1 3 Unlock the door with temporary password Operational procedure Lock indication j Input the enrolled temporary The lock beeps with a motor password rolling sound heard Otherwise it will be automatically locked 5 seconds later Temporary pass
18. e of batteries The lock will make alarm sound and red light flashes due to insufficient voltage Please change alkaline batteries in time or every time there will be repeated red indicator light flashes with alarms heard when unlocking It can be unlocked around 100 times till batteries are changed Notes 1 Please make sure batteries are installed properly according to electrode pole listed in the battery box 2 Please use four 1 5V alkaline batteries with the same brand It may cause damage to the lock if mixing new batteries with the old ones or using non alkaline batteries 3 Recycle the old batteries for environment protection Operation steps Remove screws which fix the battery box cover by hex wrench gt remove battery cover gt change batteries install battery cover gt fix the screw 21 sasana AIEL 747 5600MFI2S C31sets Operation Instruction IV Maintenance 4 1 Daily maintenance 1 Do not clean the lock surface with corrosive substance or else the protection layer may be damaged and thus influence the gloss of the lock surface Please clean the lock surface periodically with furniture polish wax 2 DO NOT hang any object on the handle 3 Please adjust the strike plate if the door deformed as 1t may affect the operation of the lock 4 Please change the batteries as soon as possible if the lock works under insufficient voltage Please use four 1 5V alkaline batteries with the same brand it m
19. en the lock is in the passage mode it can be unlocked without any electronic keys That is to say you can just turn the handle to open the door Therefore please remember to cancel the passage mode in time 4 8 Usage of emergency key 1 Remove handle Take out the screws by hex wrench and remove front handle 2 Unlock by key Insert and turn the mechanical key to unlock the lock 4 9 Change of batteries If the lock works under insufficient voltage it will beep alarms with red indicator light flashing when unlocking It s highly recommended to change the batteries as soon as possible Operation steps 1 Remove the battery cover with cross screwdriver 2 Change batteries 3 Reinstall the battery cover ae tomi gi ADEL747 5600MF12S 3lsets Operation Instruction i FET FE META ADEL747 5600 MF12S S Operation Instruction Shenzhen Ideal Microelectronics Co LLU DEOVIUCS A2L LUOULIU WULU assistance for users please contact our exclusive distributors throughout the world or contact our head office directly SHENZHEN IDEAL MICROELECTRONICS CO LTD Address Bldg 4 Xili Nangang Second Industrial Park Songbai Road Nanshan District Shenzhen China Tel 86 755 27657755 Fax 86 755 27652282 E mail service adellock com Website http www adellock com sale AIEL 747 5600MFI2S C31sets Operation Instruction Acknowledgement Dear user Thanks very much for your selection of ADEL smart loc
20. ical key Please keep the mechanical key in a proper place It s required to use ADLE Mifare card for the lock Electronic keys mentioned in this manual include ADEL Mifare card and password ADEL ADEL747 5600MF12S 31sets Operation Instruction I Overview 1 1 Product features 1 1 1 Product introduction A Lock body 59600 Mifare card Password IN Model Front lock body Back lock body O B Mortise with single latch single latch 8 ADEL ADEL747 5600MF12S 31sets Operation Instruction 1 1 2 Features Ls Unlocking the door by either ADEL Mifare card or password 12 digit password will cater to user s usage pattern Up to 31 sets of password and 62 Mifare cards Independent management mode you can add delete electronic keys independently for your convenience International standard operation Power supply four 1 5V AA alkaline batteries can support the lock to operate around 10 000 times Low voltage alarm the lock will make alarm sound and red light flashes due to insufficient voltage Please change alkaline batteries in time Passage mode can be set for certain occasions LED light and alarm sound The lock will give different light colors and alarm sound for different lock status during the operation 1 1 3 Accessory 1 1 3 1 Mifare Card S H nh oF ADEL Mifare card Key card ADEL ADEL747 5600MF12S 31sets Operation Instruction 295 1 2 Structure size 1 2 1 Dimensional drawing of l
21. k ADEL governed by the belief of Innovation as soul customer as God has always committed to providing beautiful novel high tech and high quality products for customers ADEL Group was founded in 1993 with scientific research development design manufacture and sale of security intelligence products and built as an aircraft carrier in the industry The group headquartered in Shenzhen covers an area of nearly ten thousand square meters There are R amp D center test center mold processing center production center information management center marketing center customer service center and financial management center under the group Besides the group has agents and technical support service in major cities throughout the country As a high tech private enterprise group we work with U S ATMEL DALLAS BELL VERIDICOM ORACLE ONITY and Chinese Academy of Sciences for extensive technical exchanges and cooperation Until now we have won more than 200 domestic and foreign patents and 13 invention patents ADEL747 5600 MF12S lock combines RF and password technology which is the outcome of various patented technology and meticulous research and innovation With sophisticated design and superior performance the product enjoys a high reputation in the mind of consumers As lock specialist in the 21 century we will persist in the belief of Innovation as soul customer as God and continue to provide the highest quali
22. mm X Description 2mm X Single latch shaft M5 round head screws WE 45mm X 1 25mm X 1 55mm X 1 Quantity 30mm X 1 65mm X 1 40mm X 1 7omm X 1 50mm X 1 Its dimension depends on door Please use them as per Description thickness Installation Guideline M5 10 countersunk Name Screw with sharp point M4 25 head screws Picture 1 User manual Name Certificate Ll GEIER Picture a 31 sale AIEL 747 5600MFI2S 3l1sets Operation Instruction HH Reference to Product Standard and Enterprise Standard National Standards Electronic Anti theft Lock Standard GA374 2001 Mechanical Anti theft Lock Standard GA T73 94 Fireproof Door Standard GB12955 2008 International Standards Building hardware Locks and Latches Mechanically operated Locks latches and locking plates Requirements and test methods BS EN12209 2003 Positive Pressure Fire Tests of Door Assemblies ULI0C Access Control System Units UL294 High Security Electronics Locks UL2058 IV Lock Configuration Standards Refer to Installation Guide V Handle Orientation Change Refer to Installation Guide VI Assembly of Lock Connectors Refer to Installation Guide Vil Warranty Card Dear user Thanks very much for your trust and support to ADEL Company In order to better achieve the service commitment of ADEL Company please fill in the warranty card after buying the product of ADEL 32 ADEL ADEL747 5600MF12S 3lsets Operation In
23. n Steps aaa cst espe a cee AA ep eect aa e 10 II Operation InstruCfIO S lt lt 22322221133 2 EEEe zeeeeereeeeees 11 3 1 Preparation before USING ccccccccccccccceeeeeeeeeeceeeeeeeeeeeeeeeeseeeess 11 3 1 1 Button descrmtpon S2 11 3 1 2 Indication of the lock status 11 3 1 3 Technical f rIs 52222233333 5555 xerrrs 11 Dal A HCCK before Using saeka aaa a a aaa a aaa ee EKA 11 Dale OPE OOM kana anga a anaa a aan eee anana aa 12 3 2 Assignment of Mifare card and password 12 3 3 Factory E TE EE 13 Dire MATIZ AU Ola cart ae ana NA a aa A dean E Aa ANG aaa E aa AN Dgn A BANA 13 3 5 Enrollment of electronic key 14 3 5 1 Enrollment Change of master password 14 3 5 2 Enrollment Change of user password 15 3 5 3 Enrollment Change of temporary password 16 3 5 4 Enrollment of ADEL Mifare card 17 3 6 Deletion of electronic Key 17 STD TH RA A RE TAH RE PAN A RN EN AN 18 a E ee E 18 3 la Passa EE 19 E E ar E A E E 20 3 8 1 Use of mechanical key s2 20 3 8 2 Change of batteries eege eege 21 fe ET 22 4 1 Daily EIERE SS 4 2 Troubleshooting 2ssssassesososeagslaoagsgaaspssagsbaoagsgsaspsga6s5s3g46534 1856052a8a 22 NE EE 24 Del Wott TY POWC EE 24 EE CASES sas 8 3n c 25 5 3 Obtaining warranty
24. ock body ma GIG zajra ka a T IEI rI Sg mm I D a Dimensional drawing of front lock body ADE ADEL747 5600MF12S 3lsets Operation Instruction D 7 202 Dimensional drawing of back lock body ADEL ADEL747 5600MF12S 31sets Operation Instruction 1 2 2 Dimensional drawing of mortise 4 a on gt z l O O il l C E m Q H T i i WOOTIAAV d II O E SS J LA Apgrrocr ADEL ADEL747 5600MF12S 31sets Operation Instruction 1 2 3 Lock parts 125E GE Ee EAR EF AEB HS ie By et Hy Git Battery cover OU ED Dk Front lock body D degt Mortise with single latch 12 250525 4 12 digit password component HEF Handle sasana AIEL 747 5600MFI2S C31sets Operation Instruction 1 3 Product performance 1 3 1 Technical parameters Co tow voltage stam lt asv 7 7 7 7 7 1 3 2 Working environment t In 4 lt 180mA consumption ER 8 Parameters Techni
25. ry products which are not supplied by ADEL Failure or instability caused by electric power voltage air conditioner humidity control or other environmental conditions except for quality standard extent permitted of ADEL products force majeure such as earthquake water disaster flood etc and accidents etc 5 3 Obtaining warranty service amp Technical support 1 If your lock fails to unlock please operate according to solutions for common errors in the manual If it doesn t take effect please contact local customer service center of ADEL Company and provide the following information 25 sasana AIEL 747 5600MFI2S C31sets Operation Instruction C1 ADEL lock model 2 Your purchase date or use date after installation and acceptance 3 Your telephone fax and detailed address 4 Product fault conditions more detailed phenomenon problems will be solved sooner 5 Your suggestions and requirements 2 In order to re simulate the process of accident find out causes and solve product faults users should cooperate to answer the questions including site conditions fault conditions regular occasional accident operation procedures etc 3 If the problem is still not solved personnel from local customer service center of ADEL Company will provide on site service 4 It is strongly recommended that you have to check whether it s the appointed technician from ADEL 5 Please checkout maintenance effect
26. site www adelfingerprint com Special Prompts 1 The above items has stipulated all responsibilities for the products of ADEL Company and replaced all other express implied guarantees or responsibilities When the products run abnormally responsibilities of ADEL Company for users are limited to the maintenance or replacement in accordance with the above items There are no other guarantees apart from this If there are additional express regulations of national applicable laws ADEL Company will comply with law enforcement 2 Any direct or indirect loss caused by using the products of ADEL Company abnormally due to whatever reasons ADEL Company 21 nar waman AIDEL 747 5600MFI2S C31sets Operation Instruction only assumes the responsibilities required by national applicable laws Statement If any fault appears in use please contact local customer Service center in time ADEL Company will not assume any responsibilities in case of self disassembly 28 Appendix I Group number and its corresponding ADLE Mifare card Group Kame Group Namie Group Name number number number oof pe Ud gt te 29 II Packing list Front body Back body PN ANANG R LEE Picture PS I Picture Its dimension depends Description on door thickness Strike box Mechanical key Picture tini TT Mortise location pin Picture 30 ADEE ADEL747 5600MF12S 31sets nr NAN Instruction 2 5
27. struction Company so that we can create your personal file and make you enjoy more convenient thoughtful and attentive service to relieve your worries Sincerely hope our product and service can help you create a better life Mail to AISO Service Center Shenzhen Ideal Microelectronic Co Ltd Address Bldg 4 Xili Nangang Second Industrial Park Songbai Road Nanshan District Shenzhen China Tel 86 755 2765 7755 Fax 86 755 2765 2282 Email service adellock com Welcome to visit the website http www adellock com to know more information SE K E N C NG TY CO PHAN C NG NGHE VKEN VP Tang 5 S 184 Nguy n Tu n Thanh Xu n H n i Tel 0904 954 981 Email info vken vn Access control system Website www Vken com vn CATALOGUES VKEN kinh chao quy khach VKEN ch ng t i tran tr ng g i t i Qu Kh ch H ng m t s th ng tin v s n ph m do VKEN cung c p ch ng t i cam ket h ng b n ra th tr ng d u l ch nh hang chat l ng cao Rat mong nh n c s h p t c t qu kh ch Xin c m n i u Ki n Th ng mai S n ph m m i 100 theo ti u chu n c a nh s n xu t cam k t ch nh h ng Qu kh ch vui l ng Li n h Vken c b o gi ch nh x c c a t ng ng y Giao h ng trong v ng 02 ng y k t ng y k k t h p ng ho c x c nh n t h ng B o h nh theo ti u chu n c a nh s n xu t H
28. ter password user password and temporary password is 00 01 29 and 30 The enrolled temporary password can only be used once It s required to enroll again 12 after used User number also called personal password arbitrary combination of 10 digits by 0 9 at least 1 digit and the maximum 1s 8 digits A valid password consists of group number and user number For example if the group number is 05 and the user number is 123 then the password will be 05123 Group number of ADEL Mifare card 31 92 Each group number matches one ADEL Mifare card It s required to use group number when enrolling or deleting ADEL Mifare card It s not required when unlocking the door with ADEL Mifare card Please register the group numbers of the enrolled ADEL Mifare cards on the Appendix Group number and its corresponding ADEL Mifare card for future reference NOTE Enrollment operation can t be carried out when the lock is in back locking state extend the deadbolt 3 3 Factory default setting The default password is 00123 and any ADEL Mifare card can unlock the door The lock beeps three sounds with green and red indicator light flashing and a motor rolling sound heard NOTE Please enroll your password and ADEL Mifare card before using 3 4 Initialization 3 1 Please use a hex wrench to press the button which 1s on the back side of the front lock body before installation Please
29. ty products and the most sincere service for you Sincerely wish you have a happy experience of usage and enjoy the joy of life brought by high tech Thanks again for your support and love to ADEL Group Shenzhen Ideal Microelectronics Co Ltd s K 6 7 S 9 eevee tee AIDEL 747 5600MFI2S 3l1sets Operation Instruction Safety and Precautions Electronic lock is a high tech product and the installation will directly impact on its normal use and service life It s highly recommended to have the lock installed by professional technician according to the installation standards of ADEL Company DO NOT use the lock under the environment of high radiation magnetic field humidity to avoid influencing the performance and service life of the lock Please initialize the lock as soon as possible after completing the installation and then enroll the electronic key immediately to prevent the lock being unlocked illegally Please inspect key box and make sure it is in good condition before opening Please keep your enrolled electronic keys safe and mechanical keys 1n a proper place Please use four 1 5V alkaline batteries with the same brand it may cause damage to the lock if mixing new batteries with the old ones or using non alkaline batteries For better enjoy the convenience and advancement of ADEL products please read this manual carefully before using Any questions please call local customer service center or ser
30. uired to enroll again after used 16 nar ramuan AIEL 747 5600MFI2S C31sets Operation Instruction 3 5 4 Enrollment of ADEL Mifare card The lock beeps with green indicator light Input master password to enter the enrollment mode flashing Green indicator light Input the group number 31 92 and is on with red then press indicator light flashing The lock beeps two Put an ADEL Mifare card close to the sensor area of the lock sounds and red indicator light is off Enrollment of ADEL Mifare card is Green indicator light HE gn Continue to enroll other electronic keys Green indicator light D or press three times to exit kaum NOTE If the cards for enrollment have already been enrolled or are not ADEL Mifare cards the lock will beep with red indicator light flashing If the group number of Mifare card has already been occupied the lock will beep two sounds with red indicator light flashing when inputting the group number The lock will be back to the enrollment state Please input the available group number 3 6 Deletion of electronic key The lock beeps with green 1 Input master password indicator light flashing Input the group number to 2 The lock beeps three sounds be deleted such as 01 and 17 Continue to delete other electronic keys or press Green indicator light off three times to exit NOTE The lock will be restored to th
31. ust not be less than 100mm away from the door edge Bi A eT 2 2 3 Drilling template ADEL747 5600MF12S 31sets Please refer to the Installation Instructions 2 3 Installation tools Operation Instruction e Ka K i Drill Cable Extension Wood Drill Angle Square Wood Rasp Paper Cutter Screwdriver Chisel Pencil Hammer a A Twist Drill Bit Tape Measure 2 4 Installation 2 4 1 Installation steps Please refer to the Installation Instructions 10 sasana AIEL 747 5600MFI2S 3l1sets Operation Instruction LH Operation instructions 3 1Preparation before using 3 1 1 Button description Set patetgs toate GE 3 1 2 Indication of the lock status 3 1 2 1 New lock indication Any ADEL Mifare card or default password 00123 can unlock the door The lock beeps three sounds with green and red indicator light flashing and a motor rolling sound heard 3 1 2 2 Operation succeeded green light on with a long beep 3 1 2 3 Operation failed red light on with two short beeps 3 1 2 4 Unlocking indication electric engine makes a rolling sound for the first time which indicates that the lock 1s in door open state 3 1 2 5 Locking indication electric engine makes a rolling sound for the second time which indicates that the lock is in door closed status 3 1 2 6 Passage mode indication green indicator light flashes every 5 seconds
32. vice center headquartered in Shenzhen of ADEL Company directly We have professional technicians serve for you to ensure you use at ease Please visit our website WWW ADELLOCK COM to download user manual if you accidentally miss it Please add our website to your computer favorites in order for your convenience to find our service information and product description at any moment Shenzhen Ideal Microelectronics Co Ltd sasana AIEL 747 5600MFI2S C31sets Operation Instruction Contents Operation Instruction l Acknowledgement eebe 7 SE E e 8 ett 1 IN ee 2 LI re 51012infsinni sT Sa 2 1 1 1 Product introduction c2 2 RR ern e e ani 3 I AS ANC COSSOLY ss 2cccsvssdensdunsdacateca tesatvesdsesseesdasssenadecasvoidecstvosdsaeds 3 E Mare EE m co 3 EE 4 1 2 1 Dimensional drawing of lock bod y 4 1 2 2 Dimensional drawing Of mOFfISe 5555 6 ee Io eo a ae A NANA E AE NA 7 K ler 8xx 065 aa ad aaa Aan 8 13 1 Technical parameters usana wana rakan ya akng naka ya wahan ri 8 1 3 2 Working environment cc ceceeeeeeeeeeeeeeessesesssseeseeeeees 8 DSN 7P eo 8 IN BREET IR E 9 2 1 Recommendation 66618031 v 9 2 2 Installation requirement cc cceeeeeeseesssesssssssssssssssssssssseeeees 9 DL DEDI SONG pee eRe aE AE ee ee 9 EIERE ee H SE iiine 10 2 3 Installation tools 10 P e n o C 10 2 4 1 Installatio
33. word will be invalid once it s used Keypad will be locked for 5 seconds if inputting an incorrect password three times Password must be more than 4 digits including Do not press any keypad within the 5 seconds otherwise the locking time will be automatically delayed for 5 seconds again The enrolled ADEL Mifare card is available to unlock the door when the keypad is locked however the locking time will be automatically delayed for 5 seconds again 3 7 2 Passage mode 3 7 2 1 Setup of passage mode Press 0 within 5 seconds after the door is opened by the enrolled ADEL Mifare card or password and the passage mode 1s set Green indicator light will flash every 5 seconds 19 3 7 2 2 Cancellation of passage mode To cancel the passage mode please use the enrolled ADEL Mifare card or input the correct password to open the door or extend the deadbolt NOTE Passage mode is specially designed for office meetings gatherings etc When the lock is in the passage mode it can be unlocked without any electronic keys That is to say you can just turn the handle to open the door Therefore please remember to cancel the passage mode in time 3 8 Others 3 8 1 Use of mechanical key 1 Remove handle Take out the screws by hex wrench and remove the front handle 2 Unlock by key Insert and turn the mechanical key to unlock the lock 20 sasana AIEL 747 5600MFI2S C31sets Operation Instruction 3 8 2 Chang