1. Voltage DC 2 6V 3 6V Power Supply Dry battery 2AA Battery working hour Theoretical number is 44 hours Safety Type Interior Battery t BF Type Accessories Sell in standard A user manual A data line A disk PC software An oximeter probe for animal S5R150_vet Physical Identity Dimension 110 L 60 W 23 H mm Weight About 180g with Dry battery 2AA Patient Monitor CMS60A1 Patient Monitor Instructions Principle of the PM60A1 Patient Monitor is as follows Photoelectric Oxyhemoglobin Inspection Technology is adopted in accordance with Capacity Pulse Scanning amp Recording Technology the Pulse Oximeter can be used in measuring the pulse oxygen saturation and pulse rate through finger The product is suitable for being used in family hospital oxygen bar community healthcare physical care in sports It can be used before or after doing sports and it is not recommended to use the device during the process of having sport and etc Major Features Small in volume light in weight and convenient in carryingv Operation of the product is simple low power consumptionv SpO2 value displayv Pulse rate value display bar graph displayv Pulse waveform displayv The display mode can be changedv With backlight and changeable backlight timev A pulse rate sound indicationv Alarm function bases the Upper Down alarm Range have three classes voice and photosensitive alarmv With clock func
2. 20mmHg 165mmHg Diastolic Pressure 1OmmHg 150mmHg Neonatal Systolic pressure 40mmHg 135mmHg Mean pressure 20mmHg 110mmHg Diastolic Pressure 10mmHg 100mmHg Upper and lower limit of alarm Adult Systolic pressure 40mmHg 270mmHg Mean pressure 20mmHg 235mmHg Diastolic Pressure 10mmHg 215mmhHg Paediatric Systolic pressure 40mmHg 200mmHg Mean pressure 20mmHg 165mmHg Diastolic Pressure 10mmHg 150mmHg Neonatal Systolic pressure 40mmHg 135mmHg Mean pressure 20mmHg 110mmHg Diastolic Pressure 10mmHg 100mmHg SpO2 monitoring aContinuous real time measuring mAdopt digital SpO2 technology which has strong anti interference Capability mReal time display SpO2 pulse rate SpO2 Plethysmogram bar graph SpO2 and Pulse rate PR trend graph mlrend graph with the function of adaptive scaling aStandard adult finger clip probe binding probe for neonatal is optional SpO2 Measuring Range 35 100 Resolution 1 Accuracy 2 in stage of 70 100 and unspecified in stage of less than 70 Pulse Rate Measuring Range 30bpm 250bpm Resolution 1bpm Accuracy 2bpm or 2 whichever is greater Measurement Performance in Weak Filling Condition SpO2 and pulse rate can be shown correctly when pulse filling ratio is 0 4 SpO2 error is 4 the Pulse rate error is 2bpm or 2 whichever is greater Resistance to surrounding light The deviation between the value measured in the condition of man made light or
3. Features gAll round monitoring for adult pediatric and neonatal 03 5 320x240 TFT LCD Operate with button and touch screen mReview of data list and trend graph Configuring interface as user s requirements sAudible and visual alarm for each parameter and upper and lower limit of alarm can be set aBuilt in rechargeable Li polymer battery for uninterrupted monitoring mSelective SD card for storing 72 hour data Performance ECG a3 lead and 5 lead are optional aWaveform display dual lead full lead aGain selection 2 5mm mV 5mm mV 10mm mV 20mm mV aMeasurement range for Heart rate HR 30bpm 300bpm error 1bpm or 1 whichever is greater aUpper and lower limit for alarm range 30bpm 300bpm resolution 1bpm input current lt 0 1uA Enduring polarization voltage 300mV sensitivity range 5 aCMRR filter mode surgery monitoring 80dB mFrequency response 1 75Hz 0 4dB 3dB mLow frequency characteristic time constant 3 2s mAnalysis function heart rate arrhythmia analysis S T segment analysis aS T segment range 2 0mMV 2 0mV Blood Pressure aMeasurement method Oscillometry mMeasurement mode manual auto continuous mAuto measurement interval adjustable from 1 to 90 minutes mResolution 1mmHg mAccuracy Maximum Mean deviations 5mmHg Maximum Standard deviation lt 8mmHg aSelf check function mwOverpressure protection double protection for software and hardware Range Adult Systolic
4. a 0 69 unspecified Standard Configuration ECG NIBP SpO2 Optional RESP 2 TEMP 2 IBP ETCO2 Network Thermal Recorder Patient Monitor CMS7000 Multi Parameter Monitor Features m 12 1 High brightness TFT LCD display a Portable streamline handle design Big figure display a ECG Waveforms of 7 lead displayed in one screen a 96 hour tabular and graphic trends amp date storage Compatible and self identify 3 lead and 5 lead ECG cable aNIBP dual Over Pressure Protection isolated floating anti defibrillation protected and anti high frequency interference Standard parameter amp configuration m 3 5 lead ECG RESP SpO2 NIMP TEMP PR Network Optional parameter amp configuration mw 2 IBP Recorder i2 lead ECG ETCO2 Patient Monitor CMS9000 Multi Parameter Monitor Features a Colour TFT Screen waveform up to 8 channels a Light and portable with build in rechargeable battery a UP to 10 kinds of monitor parameters a Arrhythmia analysis pace marker detection and S T Segmentanalysis 72 hour storage and review of trend grams and tables 40 second review of holographic waveforms a Built in recorder option a All round monitor of adult paediatric and neonatal a Electrosurgical unit and defibrillation protected a Standard parameters ECG NIBP SPO2 Respiration Temperature Pulse rate a Option parameters EtCO2 CO IBP Thermal Printer ECG a 5 lead or 3 lead selectable a Input 5
5. unspecified ECG Lead mode 3 lead or 5 lead a HR range 15 300 bpm mw Accuracy 2bpm or 2 which is greater NIBP m Method Oscillometry Mode Manual Auto Continuous m Measurement Range 25 260mmHg SPO2 m Measurement Range 0 100 Pulse rate a Measurement Range 25 250 bpm m Accuracy 3 bpm m Dimension 210 x 130 x 210 mm m Net weight 2 3KG Patient Monitor PM 70 Patient Monitor Features m Routine Check Mode and Continuous Monitoring Mode a Data Graph and Trend Table Review a Rich Analysis Report a Sync with PC based Sofrware WinXP and WinVista m lightweight and easy to use portable unit a Built in NIBP module a Automated amp on demand NIBP measurements a User or system defined inflation pressure ECG is optional NIBP a Performance Specifications a Display 3 5 Colour TFT m Resolution 320x240 a Display Mode Standard face Waveform face Indicator Power indicator light Alarm sound Pluse tone Interface socket for connecting sensors and sockets for communication cables Power Supply DC 5V lt 300mA a Battery Built in Li Polymer 2 hours for charging 3 hours for continuous working 8 hours for standby mode m Trend Graph Resolution from 1s 5s 10s Maximum time 96 hours a Trend Table Resolution from is 5s 10s Review up to 1000 items a Alarm Adjustable High and Low limits Three level audible and visual alarm m User Configuration All the colou
6. Diagnosis 60 dB Bandwidth Surgery 1 20 Hz 0 4dB 3dB Monitor 0 5 40 Hz 0 4dB 3dB Diagnosis 0 05 75Hz 0 4dB 3dB 76Hz 150Hz 0 4dB 4 5dB Calibration Signal 1 mV Vp p 5 Accuracy ST Segment Monitoring Measuring and alarm Range 0 6 mV 0 8 mV ARR ARR Detecting Type ASYSTOLE VFIB VTAC COUPLET BIGEMINY TRIGEMINY R ONT VT gt 2 PVC TACHY BRADY MISSED BEATS PNP PNC Alarm Available Review Available Scan Speed for ECG Waveform is adjustable 12 5mm s accuracy 10 25mm s accuracy 10 50mm s accuracy 10 Respiration Method R F RA LL Impedance Differential Input Impedance gt 2 5 MQ Measuring Impedance Range 0 3 5 02 Baseline Impedance Range 1002 25002 Bandwidth 0 3 2 5 Hz Resp Rate Measuring and Alarm Range 0 120rpm Resolution 1 rpm Measuring Accuracy 2 rpm Alarm accuracy 3rpm Apnea Alarm 10 40S NIBP Method Oscillometry Mode Manual Auto Continuous Measuring Interval in AUTO Mode 1 90 Min Measuring Period in Continuous Mode 5 Min Measuring and Alarm Range 10 270mmHg Alarm Type SYS DIA MEAN Resolution Pressure 1mmHg Cuff pressure 3 mmHg Accuracy 10 or 8mmHg which is greater Over pressure Protection Adult Mode 315410 mmHg Paediatric Mode 265410 mmHg Neonatal Mode 155 10 mmHg SpO2 Measuring Range 0 100 Alarm Range 0 100 Resolution 1 Accuracy 70 100 2 0 69 unspecified Pulse Rate PR Measuring and Alarm Range 0 250bpm Resolution 1bpm Measuring Accuracy 2bpm or 2 w
7. Italian Turkey etc a Built in removable and rechargeable lithium battery a Memory Built in memory or mini SD Memory card Store more than 1000 pieces of archive a Powerful data storage and management Trend graph Trend table etc 120 hour graphic and tabular trends of all parameters 120 seconds frozen waveforms 1000 pieces of NIBP record storage 100 pieces of regular alarms review 100 pieces of ARR alarms storage a Arrhythmia analysis and S T segment analysis Specifications ECG a Lead mode 3 lead or 5 lead m HR range 15 300 bpm mw Accuracy 2bpm or 2 which is greater Respiration a Measurement Range 0 120 a Apnea alarm SPO2 a Measurement Range 0 100 mw Accuracy 2 70 100 0 69 unspecified Pulse Rate Measurement Range 25 250 bpm a Accuracy 3 bpm NIBP a Method Oscillometry a Mode Manual Auto Continuous m Measurement Range 25 260mmHg Temperature a Measurement Range 0 50 C a Resolution 0 1 C Dimension 365 x 150 x 340 mm m Net weight 4KG Optional a Parameters 12 lead ECG Dual IBP EtCO2 Thermal Recorder m Navigating options mouse keyboard Other options Wireless LAN f rF 0 i CG tx sxn Pute mane mrmertsv a D Px Sriati ere ee ry ae pops Patient Monitor PM 80 Handheld ECG Monitor Features Designed for daily home healthcare Light weight and portable size 3 5 320x240 TFT display led backlight Touch screen
8. Measuring and Alarm Range 0 250bpm Resolution 1bpm Measuring Accuracy or 2 which is greater Blood pressure Method Oscillometry Mode Manual Measuring Range 10 270mmHg Resolution 1mmHg Accuracy 10 or 8mmHg which is greater Over pressure Protection Adult Mode 315410 mmHg aTEMP Channel single channel Measuring and Alarm Range 0 50C Resolution 0 1C Accuracy 0 1C Blood glucose Sample capillary whole blood Sample Type for Calibration vein plasma Blood Size About 3ul Test Range 2 2mmol L 27 8mmol L 40mg dL 500mg dL Test Time 25 seconds Calibration Curve automatically select test curve by the correction number Memory 220 results aPhysical Characteristic Dimension 190x160x240 mm Net Weight 2 1 Kg Accessories Integration extension cable 5 pin Adult fingertip SpO2 probe DB9 Adult NIBP Cuff Air pipe for NIBP Suction ball for Limb clamp European standard ECG 5 lead wire AIP0336 European standard ECG 5 lead wire AIPO210 European standard Temperature probe Power cord Power adapter Blood Glucose Meter optional 10 lead wire for monitoring optional 10 lead suction ball for dynamic ECG optional ECG electrode Blood Glucose Test Strip optional USB wireless network card 3G wireless network card optional User Manual Patient Monitor HMS9800 Multi Parameter Vital Signs Monitor Introduction HMS9800 is a portable and intellectualized self examination machine si
9. Simple operation and rapid test ECG can be detected only be two hands or chest Basically analyse and diagnose ECG waveform heart rate and heart rhythm Provide clear ECG waveform used for diagnosing to doctor Built in memory for more than 5000 cases of measurement of single channel ECG depend on the capacity of the SD card Power capacity indication and automatic power off in energy conserving mode Specifications Leads mode bipolar single channel HR measuring range 30bpm 300bpm Bandwidth 0 05Hz 150Hz Sampling 200Hz Classification BF Battery built in lithium battery DC 3 7V Dimension 130mm L x 74mm W x 25mm H Net weight 140g Optional functions SpO2 module Monitoring of ECG and SpO2 for a long time Wireless telecommunication Patient Monitor CMS6800 Vital Signs Monitor Features a 8 TFT led backlight 800x480 pixels a Visual and Audio alarms adjustable a Patient management name age and id m Network with Central Station Software a Audio volume adjustable form 1 8 level a Multi language options Germany France Italian Turkey etc a Built in removable and rechargeable lithium battery a UI with both Keypad and Touch Screen operation a Memory Built in memory or mini SD Memory card Store more than1000 pieces of archive Powerful data storage and management Trend graph Trend table etc a Arrhythmia analysis and S T segment analysis m Accuracy 2 70 100 0 69
10. V Wave 5 lead 2 channels 3 lead 1channel Gain x2 5mm mV x5 0mm mV x10mm mV x20mm mV HR Measuring and Alarm Range Range 15 300 bpm Accuracy 1 or 1bpm which is greater Alarm Accuracy 2bpm Resolution 1 bpm CMRR Monitor 100 dB Surgery 100 dB Diagnosis 60 dB Bandwidth Surgery 1 20 Hz 0 4dB 3dB Monitor 0 5 40 Hz 0 4dB 3dB Diagnosis 0 05 75Hz 0 4dB 3dB 76Hz 150Hz 0 4dB 4 5dB Calibration Signal 1 mV Vp p 5 Accuracy ST Segment Monitoring Measuring and alarm Range 0 6 mV 0 8 mV ARR ARR Detecting Type ASYSTOLE VFIB VTAC COUPLET BIGEMINY TRIGEMINY RONT VT gt 2 PVC TACHY BRADY MISSED BEATS PNP PNC Alarm Available Review Available Scan Speed for ECG Waveform is adjustable 12 5mm s accuracy 10 25mm s accuracy 10 50mm s accuracy 10 Respiration Method R F RA LL Impedance Differential Input Impedance gt 2 5 MQ Measuring Impedance Range 0 3 5 02 Baseline Impedance Range 1002 25002 Bandwidth 0 3 2 5 Hz Resp Rate Measuring and Alarm Range 0 120rpm Resolution 1 rpm Measuring Accuracy 2 rpm Alarm accuracy 3rpm Apnea Alarm 10 40S NIBP Method Oscillometry Mode Manual Auto Continuous Measuring Interval in AUTO Mode 1 90 Min Measuring Period in Continuous Mode 5 Min Measuring and Alarm Range 10 270mmHg Alarm Type SYS DIA MEAN Resolution Pressure immHg Cuff pressure 3 mmHg Accuracy 10 or 8mmHg which is greater Over pressure Protection Ad
11. lead RA LA RL LL V or R L N F C Lead selection I Il III avR avL avF Vx CAL Gain selection 12 5mm s 25mm s 50mm s mw Accuracy 1bpm or 1 whichever is greater a Protection Withstand 4000VAC 50Hz voltage in isolation against electrosurgical and defibrillation m Calibration signal 1mV 5 m Operation modes Diagnostic Monitor Surgery a Alarm range Adult 15 300bpm a Pediatric Neonatal 15 350bpm a Alarm range 2 0mV 2 0mV a S T detection YES Arrhythmia analysis YES a Alarm YES audible and visual alarm alarm events recallable NIBP Method Oscillometry a Operation modes Manual Automatic STAT a Measurement unit mmHg KPa selectable a Measurement types Systolic Diastolic Mean m Measurement range Adult 10 270mmHg Over pressure protection YES m Resolution 1mmHg a Accuracy Mean error and standard deviation per ANSI AAMI SP 10 a Alarm Systolic Diastolic Mean SpO2 a Measurement range 0 100 mw Accuracy 2digit 70 100 a 0 69 unspecified m Alarm range 0 100 Respiration m Method RA LL impedance a Paediatric Neonatal 6 150rpm m Alarm range Adult 6 120rpm a Paediatric Neonatal 6 150rpm a Apnea alarm YES Temperature m Resolution 0 1 C m Channel Dual channel a Alarm range 0 50 C Option EtCO2 Measurement Mode Side stream or mainstream a Measurement range EtCO2 0 99mmHg mw Accuracy CO2 concentration a Apnea alarm YES co m Method T
12. oxygen bar community healthcare physical care in sports It can be used before or after doing sports and it is not recommended to use the device during the process of having sport and etc J SpO2 value display J Pulse rate value display bar graph display 1 PI display J Pulse waveform display J Menu operation l Screen brightness can be changed The display mode can be changed e Pulse rate sound indication can be turned on or turned off With measured data overruns limits and low voltage alarm function upper down alarm range can be adjustable J Battery capacity indication amp Low voltage indication low voltage indicator appears before working abnormally which is due to low voltage and with alarm function amp J Connected with an external oximeter probe amp J Data storage function and the storage data can be uploaded to computer amp J Real time data can be transmitted to computers Bo S Bo Bo Bo Bol Ho Ho Ho Ho Hho Ho Main performance J Display Mode TFT Screen and LED display J Screen Resolution 320 240 J SpO2 Measuring Range 0 100 the resolution is 1 J Accuracy 70 100 2 Below 70 unspecified J PR Measuring Range 30bpm 250bpm the resolution is 1bpm J Accuracy amp 2bpm or 2 select larger amp J Measurement Performance in Weak Filling Condition SpO2 and pulse rate can be shown correctly when pulse filling ratio is 0 4 SpO2 error is 4
13. pressure 4OmmHg 270mmHg Mean pressure 20mmHg 235mmHg Diastolic Pressure 10mmHg 215mmHg Pediatric Systolic pressure 4OmmHg 200mmHg Mean pressure 20mmHg 165mmHg Diastolic Pressure 10mmHg 150mmHg Neonatal Systolic pressure 4OmmHg 135mmHg Mean pressure 20mmHg 110mmHg Diastolic Pressure 10mmHg 100mmHg Upper and lower limit of alarm Adult Systolic pressure 4OmmHg 270mmHg Mean pressure 20mmHg 235mmHg Diastolic Pressure 10mmHg 215mmHg Pediatric Systolic pressure 4OmmHg 200mmHg Mean pressure 20mmHg 165mmHg Diastolic Pressure 10mmHg 150mmHg Neonatal Systolic pressure 4OmmHg 135mmHg Mean pressure 20mmHg 110mmHg Diastolic Pressure 10mMmHg 100mmHg SpO2 monitoring Continuous real time measuring mAdopt digital SpO2 technology which has strong anti interference capability Real time display SpO2 Pulse rate SpO2 Plethysmogram bar graph SpO2 and Pulse rate PR trend graph Trend graph with the function of adaptive scaling aStandard finger clip probe for adult binding probe for neonatal is optional SpO2 Measuring Range 35 100 Resolution 1 Accuracy 2 in stage of 70 100 and unspecified in stage of less than 70 Pulse Rate Measuring Range 30bpm 250bpm Resolution 1bpm Accuracy 2bpm or 2 whichever is greater Measurement Performance in Weak Filling Condition SpO2 and Pulse rate can be shown correctly when pulse filling ratio is 0 4 SpO2 error is 4 the Pulse rate e
14. Alarm Available sIBP Channel dual channel Label ART PA CVP RAP LAP ICP Pi P2 Measuring and Alarm Range 50 350 mm Hg Resolution 1mm Hg Accuracy 2 or 1mm Hg which is greater sRecorder Print Mode thermal array Recording Width 48mm Paper Speed 25mm s 50mm s Quantity of Printing Waveform dual channel aPhysical Characteristic Dimension 365 x 150 x 340 mm Net Weight 4 0Kg Accessories mAdult SpO2 probe 5 pin mAdult NIBP cuff mExtending tube for NIBP mECG lead mECG electrode ml emperature probe sIBP sensor optional gIBP integration module optional IBP cable optional CO2 module optional mCO2 collection pipe optional mPower cord mUser Manual Patient Monitor CMS7OOOPLUS Patient Monitor Introduction This equipment with touch screen can monitor such parameters as ECG RESP SpO2 NIBP and Dual channel TEMP It integrates parameter measuring module display and recorder in one device to form a compact and portable device At the same time its built in replaceable battery provides convenience for patient moving Features Elegant appearance clear marks standard interface oxyCRG SCREEN trend graph big characters other BED observation which are convenient for user Be applicable for adult paediatric and neonatal aStandard parameters of ECG RESP NIBP SpO2 and dual channel TEMP IBP CO2 built in printer curving handle moving bracket and hanging bracket are optional a
15. B interface Can upload patient information data collection project and download collection data Can display scoop shape trend graph filling type trend graph histogram pie chart correlation line graph aCan edit every piece of data and add annotation to it Can edit basic information doctor s advice information NIBP and SpO2 status instruction current medicine taken information etc Support print preview print the report Patient Monitor CMS6000 Multi Parameter Monitor Features 8 4 color TFT display a Suitable for adult pediatric and neonatal patient a Basic parameters ECG SpO2 NIBP in a durable case for bedside monitoring and transport a Audible and visual alarms with adjustable alarm ranges m Networkable with CONTEC central monitoring system Powerful data management and storage capacity ECG Lead type 5 lead m Input RA LA RL LL V Sweep speed 12 5mm s 25mm s 50mm s mw Accuracy bpm or whichever is greater a Protection Withstand 4000VAC 50Hz voltage in isolation against electrosurgical and defibrillation m S T detection YES Arrhythmia analysis YES a Alarm YES audible and visual alarm alarm events recallable NIBP a Method Oscillometry a Operation modes Manual Automatic STAT a Measurement unit mmHg KPa selectable a Measurement types Systolic Diastolic Mean a Over pressure protection YES SpO2 a Measurement range 0 100 mw Accuracy 2digit 70 100
16. EONATAL SYS 40mmHg 135mmHg MAP 20mmHg 110mmHg DIA 10mmHg 100mmHg Automatic measure Interval 5 10 15 20 30 45 60 90 120 minutes Resolution I1mmHg Accuracy 3mmHg Increasing pressure mode force pump increases pressure automatically Reducing pressure mode self motion ladder reducing pressure mode Alarm parameter SYS MAP DIA aSPO2 Measure range 0 100 Resolution 1 Accuracy 70 100 2 below 70 unspecified Error in Weak Filling Condition SpO2 and pulse rate can be shown correctly when pulse filling ratio is 0 4 SpO2 error is 4 pulse rate error is 2 bpm or 2 select larger Resistance to surrounding light The deviation between the value measured in the condition of man made light or indoor natural light and that of darkroom is less than 1 Pulse Rate Measuring range Obpm 250bpm Resolution 1bpm Accuracy 2 bpm or 2 select larger aDisplay 2 4 TFT colour LCD mPower DC 3V Two AA 1 5V Alkali Battery Product safety type Type BF applied part Internally powered defibrillation proof Physics speciality Dimension 128mm 69mm 36 mm No including Packing Weight lt 350g Including Batteries Accessories aCuff for adult mintegrative SpO2 Probe aUSB data line mDisk PC software mPack wUser manual Software function aUp to 1000 patient cases can be edited and supervised aThe time segment of dealing with the patient s NIBP data is 48 hours mConnect the device by US
17. Finish all operations by touch screen or keys and knobs Operation interface with Chinese and English Optional languages French German Italian Dutch Portuguese Turkish Spanish Polish design with full built in module stable and reliable performance 12 1 colour TFT LCD with high resolution displays patient parameter and waveform and alarm bed NO clock state and other information provided by the monitor synchronously aMonitoring contents scan speed volume and output contents can be set optionally Storage of 480 hour trend data and review of 40 second holographic waveform aStorage and review of 72 hour ECG waveform sFunction of NIBP review storage for up to 2400 NIBP data mAdopt digital SpO2 technology which has strong anti interference and anti weak filling capability Calculation of drug concentration aNetwork connecting with central station other Bed observation and software updating Connection mode wireless and wired mBuilt in rechargeable battery for uninterrupted monitoring aPrint ECG SpO2 RESP BP and temperature data with one key Performance ECG Lead Mode 3 lead and 5 lead are optional Lead Selection I II III avR avL avF V Wave 5 lead 2 channels 3 lead 1ichannel Gain X2 5mm mV x5 0mm mV x10mm mV x20mm mV HR Measuring and Alarm Range Range 15 300 bpm Accuracy 1 or 1bpm which is greater Alarm Accuracy 2bpm Resolution 1 bpm CMRR Monitor 100 dB Surgery 100 dB
18. Patient Monitor CM400PC Monitoring Module y Brief introduction CM400 PC monitoring module can cooperate with PC to compose a set of complete patient monitoring system Adapting the design of modularization the device can be used as the monitor of single or multiply parameters freely Small in size and perfect in function this device can monitor ECG NIBP SpO2 for adult paediatric neonate all ages of patients at the same time Main features Applicable for adult paediatric neonate all ages of patients Real time data is showed by PC Data list and trend graph review functions The interface can be set up by your need Case and alarm data can be stored on the harddrive of PC Perfect sound and display alarm functions for parameter and technical The upper and lower limits of alarm parameter can be adjusted according to users needs Performance ECG Waveform display 3 lead full lead Gain 2 5mm mV 5mm mV 10mm mV 20mm mvV HR measuring range 15bpm 300bpm error the larger of 1bpm and 1 ECG alarm range of upper and lower limits 15bpm 300bpm resolution 1bpm Input circuit current lt 0 1pA Enduring polarization voltage adding 300mV DC polarization voltage the variation range of sensitivity is 5 CMRR filtering mode monitor surgery Zz80dB Amplitude frequency characteristic 1 75Hz 0 4dB 3dB Low frequency characteristic time constant 3 2s ECG analysis heart rate arrhythmia a
19. and review mConvenient operation by touch screen 13 arrhythmia classification and 2 channel ST segment analysis Large SD card memory 72 hour ECG graphic 480hour tabular trends of all parameters 28800 pieces of regular alarms review 28800 pieces of ARR alarms storage mPower Supply Built in Li Polymer 2 hours for charging 4 hours for continuous working Trend Graph Resolution from is 5s 1min 5min 10min Maximum time 72 hours Trend table Resolution from 1min 5mini 10min 30min 60min Maximum time 72 hours Technical specifications Type of Protection Internally Powered Degree of Protection B mDimension 92 L x82 W x22 H mm aWeight 136g with battery ECG mLead mode 3 Leads or 5 Leads mLead selection I II III AVR AVL AVF V aHR Range 15 300bpm Alarm Range 15 300bpm mAccuracy 2bmp or 2 which is greater Patient Monitor PM60A Patient Instructions Principle of the PM60A patient Monitor is as follows Photoelectric Oxyhemoglobin Inspection Technology is adopted in accordance with Capacity Pulse Scanning amp Recording Technology the Pulse Oximeter can be used in measuring the pulse oxygen saturation and pulse rate through finger The product is suitable for being used in family hospital oxygen bar community healthcare physical care in sports It can be used before or after doing sports and it is not recommended to use the device during the process of having sport and etc Major Feat
20. aturation pulse rate PR SpO2 plethysmogram wave and bar SpO2 pulse rate trend and so on The trend graph has the function of self adapting zoom A finger probe for adult is a standard accessory and a finger probe for neonate is optional 1 SpO2 saturation Measuring range 0 100 The measuring result is showed among 70 100 no define for O 70 Precision 2 2 PR Measuring range 0bpm 250bpm the resolution is 1bpm Precision the larger of 2bpm and 2 3 Error in the weak perfusion when the pulse filling degree is 0 4 both SpO2 saturation and PR can be showed accurately The error of SpO2 saturation is 4 and the error of PR is the larger of 2bpm and 2 4 Ability to resist the interference of ambient light the deviation between the measuring values in the condition of the natural light indoor or existing illuminated light sources and in the darkroom is less than 1 Standard accessories Power adapter 1 USB data line 1 ECG lead wire 1 SpO2 probe 1 NIBP cuff for adult 1 Physical characteristic Size 189mm L x 125mm W x41mm H Weight 0 5 kg Patient Monitor HMS6500 Multi Parameter Vital Signs Monitor Self Examination Machine Introduction HMS6500 is a portable self examination machine with touch screen Lightly touch corresponding icons ECG Blood pressure SpO2 PR TEMP Blood glucose can be measured and measured data can be transmitted to experts via network for further analysis which is conve
21. be set aUnique Flash memory storage for up to 2000 NIBP data and 30000 SpO2 data aConvenient and quick in inquiring measurement data review for NIBP trend graph within 24 hour and SpO2 and Pulse rate PR trend graph within 20 hour Performance NIBP monitoring aMeasurement method Oscillometry aMeasurement mode manual auto continuous mAuto measurement interval adjustable from 1 to 90 minutes Resolution 1mmHg mAccuracy Maximum Mean deviations 5mmHg Maximum Standard deviation lt s8mmbg wSelf check function sOverpressure protection double protection for software and hardware Range Adult Systolic pressure 40mmHg 270mmHg Mean pressure 20mmHg 235mmHg Diastolic Pressure 1OmmHg 215mmHg Paediatric Systolic pressure 40mmHg 200mmHg Mean pressure 20mmHg 165mmHg Diastolic Pressure 10mmHg 150mmHg Neonatal Systolic pressure 40mmHg 135mmHg Mean pressure 20mmHg 110mmHg Diastolic Pressure 10mmHg 100mmHg Upper and lower limit of alarm Adult Systolic pressure 40mmHg 270mmHg Mean pressure 20mmHg 235mmHg Diastolic Pressure 10mmHg 215mmhHg Paediatric Systolic pressure 40mmHg 200mmHg Mean pressure 20mmHg 165mmHg Diastolic Pressure 1OmmHg 150mmHg Neonatal Systolic pressure 40mmHg 135mmHg Mean pressure 20mmHg 110mmHg Diastolic Pressure 1OmmHg 100mmHg SpO2 monitoring Continuous real time measuring Adopt digital SpO2 technology which has strong anti interference capability Rea
22. ble and visual alarm alarm events review m High resolution 12 1 color TFT display m Lightweight compact and portable ECG APO2 NIBP RESP 2 TEMP PR a Optional 2 IBP ETCO2 And thermal printer a Built in rechargeable lithium battery m ECG waveforms of 7 leads display on the same screen m 72 hours graphic and tabular trends of all parameters a 72 alarm events of all parameters recall m 32 seconds full disclosure waveform review 500 NIBP measurement date can be storage and recall m Date and waveforms colour be adjustable m Arrhythmia analysis and S T segment analysis m Suitable for adult paediatric and neonatal patient SPO2 m Measurement range 0 100 m Accuracy 70 100 2 0 69 upspecified Pulse rate m Range 20 254bpm m Accuracy 3bpm Respiration m Method RA LL impedance m Range Adult 0 120rpm pediatric neonatal 0 150rpm mw Apnca alarm Yes Temperature m Range 0 50 C m Apnca 0 1 C m Channel Dual Channel Patient Monitor CMS5000 Patient Monitor Put s CMS5000 Patient Monitor adopts Oscillometry for NIBP measuring Photoelectric Oxyhemoglobin Inspection Technology combining Capacity Pulse Scanning amp Recording Technology for SpO2 measuring Systolic Pressure SYS Diastolic Pressure DIA Mean Pressure MAP SpO2 and Pulse rate PR can be accurately measured Compact appearance comprehensive functions simple and convenient operation which is applicable for hospitals commu
23. bpm v Accuracy 2bpm or 2 select larger v Measurement Performance in Weak Filling Condition SpO2 and pulse rate can be shown correctly when pulse filling ratio is 0 4 SpO2 error is 4 pulse rate error is 2 bpm or 2 select larger v Resistance to surrounding light The deviation between the value measured in the condition of man made light or indoor natural light and that of darkroom is less than 1 v Power Consumption less than 300mA v Voltage DC 5 0V v Power Supply Built in recharge Li Polymer v Battery working hour 7 hours v Safety Type Interior Battery BF Type Accessories Sell in standard v a user manual v a power adapter Model CMS0105 v A power wire v 4A bracket v a disk PC software a user manual v An oximeter probe Sell in addition Other oximeter probe Refer to probe application instruction for details and notice renewal Physical Identity Dimension 92 W x82 H x22 D mm Weight Abouti36g with battery Patient Monitor CMS8000 Patient Monitor 2482260 Features NIBP m Method Oscillometry m Modes Manual Auto Continuous a Auto measure time Adjustable m Measurement rang 10 270mmHg ECG m Lead mode 3 lead or 5 lead a Lead selection I II III avR avL avF V a Heart rate range Adult 15 300bpm Pediatric Neonatal 15 300bpm ECG waveform 2 channels m Accuracy 1 bpm or 1 a S T segment detection Measurement rang 0 2mv 2 0mv m Alarm Yes audi
24. er BED observation which are convenient for user mBe applicable for adult pediatric and neonatal aStandard parameters of ECG RESP NIBP SpO2 and dual channel TEMP IBP CO2 built in printer curving handle moving bracket and hanging bracket are optional aFinish all operations by touch screen or keys and knobs Operation interface with Chinese and English Optional languages French German Italian Dutch Portuguese Turkish Spanish Poland design with full built in module stable and reliable performance 12 1 colour TFT LCD with high resolution displays patient parameter and waveform and alarm bed NO clock state and other information provided by the monitor synchronously aMonitoring contents scan speed volume and output contents can be set optionally mStorage of 480 hour trend data and review of 40 second holographic waveform aStorage and review of 72 hour ECG waveform sFunction of NIBP review storage for up to 2400 NIBP data mAdopt digital SpO2 technology which has strong anti interference and anti weak filling capability Calculation of drug concentration aNetwork connecting with central station other Bed observation and software updating Connection mode wireless and wired aBuilt in rechargeable battery for uninterrupted monitoring Print ECG SpO2 RESP BP and temperature data with one key Performance ECG Lead Mode 3 lead and 5 lead are optional Lead Selection I II III avR avL avF
25. etecting Type ASYSTOLE VFIB VTAC COUPLET BIGEMINY TRIGEMINY R ON T VT gt 2 PVC TACHY BRADY MISSED BEATS PNP PNC Alarm Available Review Available Scan Speed for ECG Waveform 12 5mm s 25mm s 50mm s sRespiration RESP Method R F RA LL Impedance Measuring and Alarm Range for Resp Rate Adult 0 120rpm Paediatric and Neonatal 0 150rpm Resolution 1 rpm Measuring Accuracy 2 rpm Apnea Alarm 10 40S aSpO2 Measuring and Alarm Range 0 100 Resolution 1 Accuracy 70 100 2 0 69 unspecified PR Measuring and Alarm Range 0 250bpm Resolution 1bpm Measuring Accuracy 2bpm or 2 which is greater Alarm Accuracy 2bpm aNIBP Method Oscillometry Mode Manual Auto continuous Measuring Interval in AUTO Mode 1 2 3 4 5 10 15 30 60 90 Min Measuring Period in Continuous Mode 5 Min Measuring and Alarm Range 10 270mmHg Resolution 1 mmHg Accuracy 10 or 8mmuHg which is greater Over pressure Protection Adult Mode 315410 mmHg Paediatric Mode 265 10 mmHg Neonatal Mode 155410 mmHg aTEMP Channel dual channel Measuring and Alarm Range 0 50C Resolution 0 1C Accuracy 0 1C Optional sEtCO2 Method Side stream or Mainstream Measuring Range for CO2 0150mmHg Resolution for CO2 0 1 mm Hg Oto 69 mm Hg 0 25 mm Hg 70 to 150 mm Hg Accuracy for CO2 0 40 mm Hg 2 mm Hg 41 70 mm Hg 5 71 100 mm Hg 8 101 150 mm Hg 10 Respiration Rate gt 80BPM 12 AwRR Range 2 150 rpm AwRR Accuracy 1BPM Apnea
26. hermo dilution m Measurement range CO 0 1 20 lit min IBP m Channel 2 channels m Pressure transducer Sensitivity 5 mV V mmHg m Transducer sites ART PA CVP RAP LAP ICP m Alarm range 10 300mmHg Patient Monitor CMS9000 Central Monitoring System i i t I i Features aNetworked to CMS9000 patient monitor mOptional dual screen display aUp to 64 bedside monitors connectable gsHigh resolution display of 32 waveforms for 16 beds simultaneously with user selectable size mReview of the latest 720 alarm events for each bedside monitor mReview of the latest 6 minutes short trend and 240 hours trend for each bedside aDisplay of multi lead ECG waveforms and S T segment u72 hour full disclosure waveform store and review al hermal recorder and optional laser printer 010 000 history patient monitoring information m All round system help information including operation guide of central monitoring system and patient monitor
27. hich is greater Alarm Accuracy 2bpm TEMP Channel dual channel Measuring and Alarm Range 0 50C Resolution 0 1C Accuracy 0 1C Actualization Interval about 1 Sec Average Time Constant lt 10 Sec Alarm responding Time lt 2min EtCO2 Method Side stream or Main stream Measuring Range for CO2 0 150mmHg Resolution for CO2 0 1 mm Hg 0 to 69 mm Hg 0 25 mm Hg 70 to 150 mm Hg Accuracy for CO2 0 40 mm Hg 2 mm Hg 41 70 mm Hg 5 71 100 mm Hg 8 101 150 mm Hg 10 Respiration Rate gt 80BPM 12 AwRR Range 2 150 rpm AwRR Accuracy 1BPM Apnea Alarm Available mIBP Channel dual channel Label ART PA CVP RAP LAP ICP P1 P2 Measuring and Alarm Range 50 350 mm Hg Resolution 1 mm Hg mAccuracy 2 or 1mm Hg which is greater mDisplay Mode 12 1 colour TFT LCD with high resolution mPower Supply 220V 50Hz aSafety Classification class I type CF defibrillation proof part mPhysical Characteristic Dimension 310x140x263 mm Net weight 3 8Kg Accessories CMS7000PLUS Patient Monitor Introduction This equipment with touch screen can monitor such parameters as ECG RESP SpO2 NIBP and Dual channel TEMP It integrates parameter measuring module display and recorder in one device to form a compact and portable device At the same time its built in replaceable battery provides convenience for patient moving Features mElegant appearance clear marks standard interface oxyCRG SCREEN trend graph big characters oth
28. ical unit and NIBP dual overpressure protection Features aDisplay mode 15 colour TFT LCD with high resolution mBe applicable for adult paediatric and neonatal for all round monitoring Operation interface with Chinese and English aWaveform and data can be set optionally aStorage of 72 hour trend data and review of 40 second holographic waveform aFull lead ECG display u 7 lead ECG displays in a screen and ECG waveforms series display sAnti high frequency surgical unit defibrillation proof requirement for special leads wAdopt digital SpO2 technology which has strong anti interference and anti weak filling capability sFunction of NIBP review storage for up to 400 NIBP data aNetwork connecting with central station other Bed observation and software updating aNetwork connection mode wireless and wired aBuilt in rechargeable battery for uninterrupted monitoring aStandard parameters of ECG RESP NIBP SpO2 TEMP and PR aBuilt in printer optional aStandard parameters of ECG RESP NIBP SpO2 and TEMP gIBP CO2 and thermal printer are optional Performance sECG Lead Mode 3 lead and 5 lead are optional Lead Selection I II III avR avL avF V Wave 5 lead 2 channels 3 lead 1ichannel Gain x0 25 x0 5 x1 x2 HR Measuring and Alarm Range Range 15 300 bpm Accuracy 1 or 1bpm which is greater Alarm Accuracy 2bpm Resolution 1 bpm aST Segment Monitoring Measuring and Alarm Range 0 6 mV 0 8 mV ARR ARR D
29. imits wAdjustable screen brightness Real time clock Time power on off and manual power on off aTF card multi case record Data uploaded by internal card reader aPC analysis software Specifications mPower Supply ONE 3 7V Lithium Battery mDisplay 1 8 colour OLED aDimension 69mm L x 50mm W x17 3mm H Patient Monitor PM60E Patient Monitor Features aThe monitor provides such functions as audible alarm trend data storage and output alarm event marking aWith user friendly interface Be applicable for adult and paediatrics for whole age mRegular measurement and continuous monitoring mode sData list and trend graph review mTouch screen operation Comprehensive analysis function aBuilt in Li polymer battery Environment Temperature Working 5 40 C Transportation and storage 10 55 C Humidity Working 30 75 Transportation and storage lt 95 Atmospheric pressure Working 700hPa 1060hPa Transportation and storage 500hPa 1060hPa Specification SpO2 aMeasurement and alarm range 0 100 mResolution 1 wError 70 100 2 0 69 unspecified EtCO2 aMeasurement mode side stream or main stream aCO2 measurement range 0 150mmHg aCO2 resolution 0 1 mm Hg 0 to 69 mm Hg0 25 mm Hg 70 to 150 mm Hg aCO2 accuracy 0 40 mm Hg 2 mm Hg41 70 mm Hg 5 71 100 mm Hg 8 101 150 mm Hg 10 Respiration rate gt 80BPM 12 sRange of Air Way Respiration Rate AWRR 2 150BPM mAccuracy of Air Way Respirat
30. indoor natural light and that of darkroom is less than 1 Accessories mA power cord mA SpO2 probe mAn adult BP cuff mAn extending tube for blood pressure Physical characteristic Dimension 232 L x198 W x75 H mm Weight 1 15kg Certification documents Domestic registration CE certification Patient Monitor PM50 Patient Monitor Introduction PM50 is a multifunctional patient monitor it can monitor SPO2 and NIBP for a long time and applies to the hospital wards or family daily health care Features Compact and portable easy to use aWith Integrative SpO2 Probe Double working modes monitoring function and 24 hours ambulatory NIBP measure function can be flexibly set aNIBP and SpO2 can be monitored for a long time aNIBP and SpO2 data record for large capacity aWith friendly user interface the user can see list menu and review measure results mThe device can display low power information alarm information error information and time information richly sParameter alarm function is optional sPatient information can be flexibly set mCase management function PC software can achieve data review analysis measure results seeing trend printing reports and other functions Performance aNIBP Measure Method Oscillometry Measure Mode The upper arm measure Measure range ADULT SYS 40mmHg 270mmHg MAP 20mmHg 235mmHg DIA 10mmHg 215mmHg PEDIATRIC SYS 40mmHg 200mmHg MAP 20mmHg 165mmHg DIA 10mmHg 150mmHg N
31. ion Rate AWRR 1BPM mApnea alarm YES Patient Monitor CMS6500 Vital Signs Monitor Features m 7 TFT touch screen led backlight 800x480 pixels a Visual and Audio alarms adjustable a Patient management name and age and id m Network with Central Station Software a Audio volume adjustable form 1 8 level a Multi language options Germany France Italian Turkey etc a Built in removable and rechargeable lithium battery a UI with both Keypad and Touch Screen operation a Memory Built in memory or mini SD Memory card Store more than 1000 pieces of archive Powerful data storage and management Trend graph Trend table etc a Arrhythmia analysis and S T segment analysis Specifications ECG m Lead mode 3 lead or 5 lead m HR range 15 300 bpm mw Accuracy 2bpm or 42 which is greater NIBP a Method Oscillometry a Mode Manual Auto Continuous m Measurement Range 25 260mmHg SPO2 m Measurement Range 0 100 a Accuracy 2 70 100 0 69 unspecified Pulse Rate a Measurement Range 25 250 bpm m Accuracy 3 bpm Dimension 191 x 160 x 244 mm m Net weight 2 1KG Patient Monitor CMS9100 Patient Monitor Features a 15 TFT led backlight 1024x768 pixels a Visual and Audio alarms adjustable a Patient management name and age and id m Network with Central Station Software a Audio volume adjustable form 1 8 level a Multi language options Germany France
32. l time display SpO2 pulse rate SpO2 Plethysmogram bar graph SpO2 and Pulse rate PR trend graph Standard finger clip probe for adult binding probe for neonatal is optional SpO2 Measuring Range 35 100 Resolution 1 Accuracy 2 in stage of 70 100 and unspecified in stage of less than 70 Pulse Rate Measuring Range 30bpm 250bpm Resolution 1bpm Accuracy 2bpm or 2 whichever is greater Measurement Performance in Weak Filling Condition SpO2 and pulse rate can be shown correctly when pulse filling ratio is 0 4 SpO2 error is 4 the Pulse rate error is 2bpm or 2 whichever is greater Resistance to surrounding light The deviation between the value measured in the condition of man made light or indoor natural light and that of darkroom is less than 1 Accessories power cord A power adapter A SpO2 probe An adult NIBP cuff An extending tube for blood pressure Physical characteristic Dimension for product 190 L x162 W x240 H mm Weight 1 6kg Dimension for packaging 402 L x228 W x320 H mm Patient Monitor CMS70A Pulse Oximeter Instructions Principle of the CMS70A Pulse Oximeter is as follows Photoelectric Oxyhemoglobin Inspection Technology is adopted in accordance with Capacity Pulse Scanning amp Recording Technology the Pulse Oximeter can be used in measuring the pulse oxygen saturation and pulse rate through finger The product is suitable for being used in family hospital
33. mple in operating and fashion in appearance ECG Blood pressure SpO2 TEMP Blood glucose height and weight can be measured within one second and measured data can be transmitted to experts via network for further analysis which is convenient for user consulting At the same time data also can be uploaded to data centre for user viewing data and ECG within 10 seconds Furthermore user with gold and silver card can obtain professional opinion of examination data from different experts User registered with telephone number can receive the messages after examination Features aDisplay mode 17 colour LCD with high resolution a7 lead ECG display and one channel SpO2 display mAdopt digital SpO2 technology which has strong anti interference and anti weak filling capability Only be suitable for adult User data terminal of PHMS health management system mECG Blood pressure SpO2 PR TEMP Blood glucose weight and height within one minute can be measured aMeasured data can be uploaded to PHMS data management center aSelect different experts for consultation aNetwork connection mode 3G aStandard parameters of ECG SpO2 Blood pressure TEMP blood glucose and weight Performance ECG Lead Mode 5 lead Gain x1 Lead Selection I II III avR avL avF V Wave 7 channel ECG Measuring Range 15 300bpm Display Error 1 or tibpm which is greater Resolution 1bpm Scan Speed for Waveform 25mm s a SpO2 Waveform o
34. nalysis ST analysis ST analysis range 2 0mV 2 0mV NIBP Measuring method oscillometry method Measuring mode manual automatic continuous Interval of automatic measurement adjustable among 1 90 min Resolution 1mmHg Measuring precision maximal average deviation is no more thant5mmHg and maximal standard deviation is no more than 8mmHg Self checking function Overpressure protection both software and hardware double overvoltage protection 1 Measuring range Adult Systolic pressure 40mmHg 270mmHg Average pressure 20mmHg 235mmHg Diastolic pressure 1OmmHg 215mmHg Paediatric Systolic pressure 4OmmHg 200mmHg Average pressure 20mmHg 165mmHg Diastolic pressure 1OmmHg 150mmHg Neonate Systolic pressure 4OmmHg 135mmHg Average pressure 20mmHg 110mmHg Diastolic pressure 1OmmHg 100mmHg 2 Alarm upper and lower limits Adult Systolic pressure 4OmmHg 270mmHg Average pressure 20mmHg 235mmHg Diastolic pressure 1OmmHg 215mmHg Paediatric Systolic pressure 40mmHg 200mmHg Average pressure 20mmHg 165mmHg Diastolic pressure 1OmmHg 150mmHg Neonate Systolic pressure 4OmmHg 135mmHg Average pressure 20mmHg 110mmHg Diastolic pressure 10mmHg 100mmHg Interval of automatic measurement 1 2 3 4 5 10 15 30 60 90min error is less than 10s SpO2 Continuous and real time measurement Digital SpO2 technology capable to resist movement interference Real time display of multi function such as SpO2 s
35. ne channel Measuring Range 0 100 Resolution 1 Accuracy 70 100 2 0 69 unspecified Blood pressure Method Oscillometry Mode Manual Measuring Range 10 270mmHg Resolution immHg Accuracy 10 or 8mmHg which is greater Over pressure Protection Adult Mode 315410 mmHg a TEMP Channel single channel Measuring and Alarm Range 0 50C Resolution 0 1C Accuracy 0 1C Blood glucose Sample apillary whole blood Sample Type for Calibration vein plasma Blood Size about 3ul Test Range 2 2mmol L 27 8mmol L 40mg dL 500mg dL Test Time 25 seconds Calibration Curve automatically select test curve by the correction number Memory 220 results sWeight Measuring range OKG 150KG accuracy 0 1KG sHeight Measuring range OCM 210CM accuracy lt 0 5CM Physical Characteristic Dimension 108x52x250 Net Weight 48 Kg Accessories Adult fingertip SpO2 probe Adult NIBP Cuff Air pipe for NIBP Suction ball for Limb clamp European standard ECG 5 lead wire European standard Temperature probe Power cord Power adapter Blood Glucose Meter Blood Glucose Test Strip 3G wireless network card User Manual Patient Monitor CMS9200 Patient Monitor Introduction CMS9200 features in high cost performance high safety and low power consumption To ensure monitoring quality and reduce operation risk it adopts full isolation floating ECG defibrillation proof protection ECG anti high frequency surg
36. nient for user consulting At the same time data also can be uploaded to data center for user viewing data and ECG within 10 seconds Furthermore user with gold and silver card can obtain professional opinion of examination data from different experts User registered with telephone number can receive the messages after examination Features aDisplay mode 7 colour LCD with high resolution aSimple and shortcut for operating with touch screen aWaveform and data colour can be set optionally u 7 lead ECG display optional 12 lead wAdopt digital SpO2 technology which has strong anti interference and anti weak filling capability User data terminal of PHMS health management system mECG Blood pressure SpO2 PR TEMP Blood glucose within one minute can be measured aMeasured data can be uploaded to PHMS data management centre aSelect different experts for consultation aNetwork connection mode 3G Wi Fi wired aBuilt in rechargeable lithium battery for uninterrupted monitoring aStandard parameters of ECG SpO2 Blood pressure TEMP and PR Optional parameter Blood glucose Performance ECG Lead Mode 5 lead Gain x1 Lead Selection I II III avR avL avF V Wave 7 channel ECG Measuring Range 15 300bpm Display Error 1 or 1bpm which is greater Resolution 1bpm Scan Speed for Waveform 5mm s aSpO2 Measuring Range 0 100 Resolution 1 Accuracy 70 100 2 0 69 unspecified sPulse Rate PR
37. nity medical treatment and family Features aBe applicable for adult paediatric and neonatal for all round monitoring easy operation and high cost performance aBe applicable for medicine surgery operating room ICU CCU emergency room obstetrics and gynaecology paediatrics aBuilt in rechargeable Li polymer battery for uninterrupted monitoring sCompact and flexible appearance easy for carrying and be suitable for indoor and outdoor in ambulance monitoring aWith user friendly interface aDisplay with 2 4 320x240 colour TFT LCD and blue highlight LED Visual and audible alarm for Systolic Pressure SYS Diastolic Pressure DIA Mean Pressure MAP SpO2 and Pulse rate PR and upper and lower limit of alarm can be set aUnique Flash memory storage for up to 2000 NIBP data or SpO2 data within 48 hour aConvenient and quick in inquiring measurement data Optional parameter temperature Performance NIBP monitoring Measurement method Oscillometry Measurement mode manual auto continuous Auto measurement interval adjustable from 1 to 255 minutes Resolution 1mmHg Accuracy Maximum Mean deviation lt 5mmHg Maximum Standard deviation lt 8mmHg Self check function Overpressure protection double protection for software and hardware Range Adult Systolic pressure 40mmHg 270mmHg Mean pressure 20mmHg 235mmHg Diastolic Pressure 10mmHg 215mmhHg Paediatric Systolic pressure 40mmHg 200mmHg Mean pressure
38. nual Adult SpO2 probe 5 pin mAdult NIBP cuff mwExtending tube for blood pressure mECG lead mECG electrode sTemperature probe mPower cord aThermal recording paper optional aUser Manual Patient Monitor CMS5100 Patient Monitor A amp gt an a eS CMS5100 Patient Monitor adopts Oscillometry for NIBP measuring Photoelectric Oxyhemoglobin Inspection Technology combining Capacity Pulse Scanning amp Recording Technology for SpO2 measuring Systolic Pressure SYS Diastolic Pressure DIA Mean Pressure MAP SpO2 and Pulse rate PR can be accurately measured Compact appearance comprehensive functions simple and convenient operation which is applicable for hospitals community medical treatment and family Features aBe applicable for adult paediatric and neonatal for all round monitoring easy operation and high cost performance mBe applicable for medicine surgery operating room ICU CCU emergency room obstetrics and gynaecology paediatrics Built in rechargeable Li polymer battery for uninterrupted monitoring sCompact and flexible appearance easy for carrying and be suitable for indoor and outdoor in ambulance monitoring aWith user friendly interface aDisplay with 2 8 320x240 colour TFT LCD and red and yellow highlight LED Visual and audible alarm for Systolic Pressure SYS Diastolic Pressure DIA Mean Pressure MAP SpO2 and Pulse rate PR and upper and lower limit of alarm can
39. pulse rate error is 2 bpm or 2 select larger amp J Resistance to surrounding light The deviation between the value measured in the condition of man made light or indoor natural light and that of darkroom is less than 1 Power Consumption About 200mA Voltage DC 3 6 4 2V Power Supply Built in recharge Li Polymer Battery working hour 9 hours Safety Type Interior Battery BF Type l Ho Hol Ho Ho Ho Bol Bol Hol d d d d cessories ell in standard J A user manual J A rechargeable lithium battery J power wire J A data line An oximeter probe J A disk PC software Sell in addition Other oximeter probe Refer to probe application instruction for details and notice renewal eee Physical Identity Dimension 269 W x 222 H x 79 D mm Weight About 1Kg Patient Monitor CMS60D Vet Pulse Oximeter Instructions Principle of the CMS60D Vet Pulse Oximeter is as follows Photoelectric Oxyhemoglobin Inspection Technology is adopted in accordance with Capacity Pulse Scanning amp Recording Technology The Veterinary Pulse Oximeter can be used in measuring the pulse oxygen saturation and pulse rate through animal s tongue or ear and so on The product is suitable for being used in family and pet hospital etc It is recommended to use the device when the animal is still Major Features Small in volume light in weight and convenient in carrying Operation of the product i
40. rror is 2bpm or 2 whichever is greater Resistance to surrounding light The deviation between the value measured in the condition of man made light or indoor natural light and that of darkroom is less than 1 Accessories mA power cord mA power adapter mAn ECG lead wire mA SpO2 probe sAn adult NIBP cuff mAn extending tube for blood pressure Physical characteristic of host Dimension 92 L x22 W x82 H mm Weight 400g including battery Patient Monitor PM60C ECG amp SPO2 Monitor Features mRoutine Check Mode and Continuous Monitoring Mode Data Graph and Trend Table Review aRich Analysis Report mPerfect Mount Solution mConvenient operation by touch screen Large SD card memory 72 hour ECG graphic 480hour tabular trends of all parameters 28800 pieces of regular alarms review 28800 pieces of ARR alarms storage Technical specifications mDimension 92 L x82 W x22 H mm aWeight 136g with battery SpO2 aMeasurement Range 0 100 mAccuracy 2 70 100 0 69 unspecified Pulse Rate Measurement Range 25 250bpm Accuracy 2bmp or 2 select larger ECG mLead mode 3 Leads or 5 Leads mLead selection I II III AVR AVL AVF V aHR Range 15 300bpm mAlarm Range 15 300bpm mAccuracy 2bmp or 2 which is greater Patient Monitor PM60B Handheld ECG Monitor Features a5 Leads 7 channel ECG sData Graph and Trend Table Review mAlarm Event Review aST segment detection mArrhythmia analysis Freeze
41. rs of parameters and waves can be set according to user s willing Technical specifications a Safety m Meet the requirements of IEC60601 series Type of Protection Class II with internal electric power supply m Degree of Protection BF m Dimension and Weight m Dimension 145 W x95 H x37 D mm m Weight 400g with battery m Operation Environment a Temperature 0 C 40 C m Humidity 15 95 a Storage Environment m Temperature 20 C 60 C m Humidity 10 95 m Patient Range a Neonate Paediatric and Adult SPO2 a Measurement Range 0 100 m Resolution 1 mw Accuracy 2 70 100 Adult Paediatric non motion 3 70 100 Neonate non motion 0 69 unspecified m Alarm Range 0 100 m Refreshing Rate 1s Pulse Rate Measurement Range 25 250 bpm a Resolution ibpm m Accuracy 3 bpm non motion m Alarm Range 25 250 bmp m Refreshing Rate 1s NIBP a Method Oscillometry Mode Manual Auto Continuous m Measurement Range 25 260mmHg a Auto Measure Interval 5 10 15 30 45 60 90 minutes m Resolution 1mmHg m Overpressure Protection 300mmHg a Alarm range 25 260mmHg Patient Monitor PM60D ECG SPO2 NIBP PR PM60D Patient Monitor is a portable device designs with modularization and can be freely combined for single parameter or multi parameter monitor And it can be used for all round monitoring for adult pediatric and neonatal for ECG NIBP and SpO2 etc
42. s simple low power consumption Operation menu for the function setting SpO2 value display Pulse rate value display bar graph display Pulse waveform display Screen brightness can be changed Pulse rate sound indication With review function With clock function With measured data overruns limits and low voltage alarm function Battery capacity indication Low voltage indication low voltage indicator appears before working abnormally which is due to low voltage and with alarm function With SpO2 value and pulse rate value of storage the storage data can be uploaded to computers Real time data can be transmitted to computers Connected with an external oximeter probe Wireless communication function CMS60DW Vet Main performance Display Mode 1 8 Colour OLED display Screen Resolution 160 128 SpO2 Measuring Range 0 100 the resolution is 1 Accuracy 70 100 2 Below 70 unspecified PR Measuring Range 30bpm 250bpm the resolution is 1bpm Accuracy 2bpm or 2 select larger Measurement Performance in Weak Filling Condition SpO2 and pulse rate can be shown correctly when pulse filling ratio is 0 4 SpO2 error is 4 pulse rate error is 2 bpm or 2 select larger Resistance to surrounding light The deviation between the value measured in the condition of man made light or indoor natural light and that of darkroom is less than 1 Power Consumption less than 100mA
43. tance tov surrounding light The deviation between the value measured in the condition of man made light or indoor natural light and that of darkroom is less than 1 Power Consumption less than 300mAv Voltage DC 5 0Vv Power Supply Built in recharge Li Polymer v Battery working hour 9 hoursv Safety Type Interior Battery BF Typev Accessories Sell in standard a user manualv 6 a USB data linev A power adapter Model CMS0105 v a disk PC software a user manual v An oximeter probev Sell in addition Other oximeter probe Refer to probe application instruction for details and notice renewal Physical Identity Dimension 130 L x73 W x25 H mm Weight About172g with battery E if KS AS J 98 074 s _ ba ors BOW Soon PMGDA1 Patient Monitor CMS RSO1 Respiration Sleep Monitor D Features The device is applied for the suffers with such diseases as SAS OSAHS COPD ARDS and vascular diseases also for the persons over 60 years It can be used in hospital or at home eSpO2 Measuring range 35 100 Accuracy 70 100 2 lt 70 unspecified Pulse Rate Measuring range 30bpm 250bpm Accuracy 2 bpm or 2 select larger aNose air flow measure Measuring range 8rpm 40rpm Accuracy 2rpm Features aWrist equipment tiny and light aConvenient operation aDisplay of SpO2 pulse rate pulse waveform and nose flow waveform wAlarms for low power finger out and exceeding l
44. tionv Full screen touch operationv Big capacity SD card case storage almost 10000 cases v Battery capacity indicationv Low voltagev indication low voltage indicator appears before working abnormally which is due to low voltage and with alarm function Connected with an external oximeter probev Trend Review Graph Table Resolution from is 5s 10s 30s 1min and so on Store latest 96 hours trend datav Alarm Adjustablev High and Low limits Three level audible and visual alarm latest 50 alarm information and waveform displays 8 seconds which 4 seconds are before a certain time when the alarm is turned on and 4 seconds are after appointed time when the alarm is turned on Wave Review Store latest 24 hours waveform of the current real time monitoring patient v Upload data Data stored in SD card can be uploaded to computer and analyzed by softwarev SpO2 Assistant v Wireless communication function PM60A1W v Main performance Display Mode 3 5 inch TFT color display v Screen Resolution 320 240v SpO2 Measuring Range 0 100 the resolution is 1 v Accuracy 70 100 2 Below 70 unspecified v PR Measuring Range 30bpm 250bpm the resolution is 1bpm v Accuracy 2bpm or 2 select larger v Measurementv Performance in Weak Filling Condition SpO2 and pulse rate can be shown correctly when pulse filling ratio is 0 4 SpO2 error is 4 pulse rate error is 2 bpm or 2 select larger Resis
45. ult Mode 315410 mmHg Pediatric Mode 265410 mmHg Neonatal Mode 155410 mmHg SpO2 Measuring Range 0 100 Alarm Range 0 100 Resolution 1 Accuracy 70 100 2 0 69 unspecified Pulse Rate PR Measuring and Alarm Range 0 250bpm Resolution 1bpm Measuring Accuracy 2bpm or 2 which is greater Alarm Accuracy 2bpm TEMP Channel dual channel Measuring and Alarm Range 0 50C Resolution 0 1C Accuracy 0 1C Actualization Interval about 1 Sec Average Time Constant lt 10 Sec Alarm responding Time lt 2min EtCO2 Method Side stream or Main stream Measuring Range for CO2 0 150mmHg Resolution for CO2 0 1 mm Hg 0 to 69 mm Hg 0 25 mm Hg 70 to 150 mm Hg Accuracy for CO2 0 40 mm Hg 2 mm Hg 41 70 mm Hg 5 71 100 mm Hg 8 101 150 mm Hg 10 Respiration Rate gt 80BPM 12 AwRR Range 2 150 rpm AwRR Accuracy 1BPM Apnea Alarm Available IBP Channel dual channel Label ART PA CVP RAP LAP ICP P1 P2 Measuring and Alarm Range 50 350 mm Hg Resolution 1 mm Hg wAccuracy 2 or 1mm Hg which is greater aDisplay Mode 12 1 color TFT LCD with high resolution mPower Supply 220V 50Hz Safety Classification class I type CF defibrillation proof part mPhysical Characteristic Dimension 310x140x263 mm Net weight 3 8Kg Accessories mAdult SpO2 probe 5 pin mAdult NIBP cuff Extending tube for blood pressure ECG lead mECG electrode sTemperature probe mPower cord aThermal recording paper optional aUser Ma
46. ures v Small in volume light in weight and convenient in carrying v Operation of the product is simple low power consumption v SpO2 value display v Pulse rate value display bar graph display v Pulse waveform display v The display mode can be changed v With backlight and changeable backlight time v A pulse rate sound indication v With measured data overruns limits and low voltage alarm function the upper down alarm range can be adjustable v With clock function v Battery capacity indication v Low voltage indication low voltage indicator appears before working abnormally which is due to low voltage and with alarm function v Connected with an external oximeter probe v Trend Graph Table Resolution from is 5s 10s 30s imin and so on Storage of latest 96 hours trend data v Alarm Adjustable High and Low limits Three level audible and visual alarm latest 50 alarm information and waveform displays 8 seconds which 4 seconds are before a certain time when the alarm is turned on and 4 seconds are after appointed time when the alarm is turned on v Upload data Data stored in SD card can be uploaded to computer and analyzed by software SpO2 Assistant Main performance v Display Mode 3 5 Color TFT display v Screen Resolution 320 240 v SpO2 Measuring Range 0 100 the resolution is 1 v Accuracy 70 100 2 Below 70 unspecified v PR Measuring Range 30bpm 250bpm the resolution is 1