Home

Quad FXO Voice Module User Manual

image

Contents

1. R restore 3 4 RMA requests iii RX dB 3 3 S service iii specifications 1 3 status options 3 4 svc mode 3 3 T TA 850 features 3 4 terminal menu 3 2 terminal menu structure 3 2 test options 3 4 test status 3 4 testing 3 1 61175407L1 1 Quad FXO Voice Module User Manual Index 1 Index tests initiated tests 3 1 self test 3 1 TX dB 3 3 warranty iii iv wiring 2 2 Index 2 Quad FXO Voice Module User Manual 61175407L1 1 Product Support Information Presales Inquiries and Applications Support Please contact your local distributor ADTRAN Applications Engineering or ADTRAN Sales Applications Engineering 800 615 1176 Sales 800 827 0807 Post Sale Support Please contact your local distributor first If your local distributor cannot help please contact ADTRAN Technical Support and have the unit serial number available Technical Support 888 AADTRAN Repair and Return If ADTRAN Technical Support determines that a repair is needed Technical Support will coordinate with the Customer and Product Service CAPS department to issue an RMA number For information regard ing equipment currently in house or possible fees associated with repair contact CAPS directly at the fol lowing number CAPS Department 256 963 8722 Identify the RMA number clearly on the package below address and return to the following address ADTRAN Customer and Product Service 6767 Old Madison Pike Buil
2. 1 4 Quad FXO Voice Module User Manual 61175407L1 Chapter 2 Installation BEFORE INSTALLING THE QUAD FXO VOICE MODULE Carefully unpack and inspect the Quad FXO Voice Module for shipping damages If you suspect damage occurred during shipping file a claim im mediately with the carrier and then contact ADTRAN Technical Support see the last page of this manual for pertinent information If possible keep the original shipping container for returning the Quad FXO Voice Module for repair or for verification of shipping damage Shipping Contents The ADTRAN shipment includes the following items e Quad FXO Voice Module e Quad FXO Voice Module User Manual Insert into the TA 850 User Manual INSTALLING THE QUAD FXO VOICE MODULE The following Step Action table describes the actions required to install the Quad FXO Voice Module Instructions for Installing the Quad FXOVoice Module Step Action Hold the Quad FXO Module by the faceplate while supporting the bottom side Align the module edges to the guide grooves for the S designated slot 3 Insert the module until the edge connector seats firmly into the backplane 4 Lock the unit in place by pushing in on the locking lever 61175407L1 Quad FXO Voice Module User Manual 2 1 Chapter 2 Installation Instructions for Installing the Quad FXOVoice Module Continued Step Action 5 Connect the cables to the associat
3. ADRAN Quad FXOVoice Module User Manual Part Number 1175407L1 61175407L1 1A February 2000 ADRAN 901 Explorer Boulevard P O Box 140000 Huntsville AL 35814 4000 256 963 8000 2000 ADTRAN Inc All Rights Reserved Printed in U S A Federal Communications Commission FCC Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class A digital device pur suant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio frequencies Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Shielded cables must be used with this unit to ensure compliance with Class A FCC limits Change or modifications to this unit not expressly approved by the party responsible for d y W ARNING compliance could void the user s authority to operate the equipment Canadian Emissions Requirements This digital apparatus does not exceed the Class A limits for radio noise emissions from digital appa ratus as set out in the interference causing equipment standard e
4. Loopback Test naar Run nn 3 4 Network On Hook Off Hook Test c ccceccccccccccsssscccsssscesscesesssececssecesssssesssecseesssessessesssssesseusesseeseees 3 4 1004 Hz Odbm0 Tone Generation Test ccccccccssccssecessccsseecsseesseecseceseecsseeessceeesecsseeesecesseesaeeeaees 3 4 Test Status A Isa sn nenne E ten ees 3 4 Quad FXO Voice Module Status Cptiong EE 3 4 TA 850 Features Used with Quad FXO Voice Module Options n eenennnnnenn 3 4 61175407L1 Quad FXO Voice Module User Manual v Table of Contents vi Quad FXO Voice Module User Manual 61175407L1 List of Figures Figure 1 1 Quad FXO Voice Module 222 2u2202e2 22a sanieren 1 1 Figure 2 1 Connector Pin Assignments u snsuisenukeysskuuiineiskkunaklsnshleuiianusahn 2 2 Figure 3 1 Quad FXO Voice Module Menu Options NEE 3 3 vii 61175407L1 Quad FXO Voice Module User Manual List of Figures viii Quad FXO Voice Module User Manual 61175407L1 Chapter 1 Introduction QUAD FXO VOICE MODULE OVERVIEW The Quad FXO Voice Module see Figure 1 1 is for use in the Total Access 750 850 1500 TA 750 850 1500 platforms to provide analog voice exten sion The Quad FXO resides in the TA chassis that is next to or close to the customer s telephone and is usually located on the customer s premises This unit can be used in conjunction with the TA 750 850 1500 FXS Voice Module which resides in the TA 750 850 1500 that is located next to
5. atures The top most menu level leads to submenus which are grouped by functionality All menu items display in the terminal window To access the Quad FXO Voice Module activate the MODULES menu Ka Refer to the TA 850 User Manual for detailed instructions on navigating through the terminal menu From the MODULES menu select the QUAD FXO menu and then press Enter to access the features of the Quad FXO card 3 2 Quad FXO Voice Module User Manual 61175407L1 Chapter 3 Operation QUAD FXO VOICE MODULE MENU OPTIONS Figure 3 1 shows the menu options available for the Quad FXO Voice Mod ule The following sections describe these options elba n onfiguration Menu Figure 3 1 Quad FXO Voice Module Menu Options PRT Identifies the port involved MODE Options are given below Loop START Sets the port to use FXO loop start signalling on the T span and loop start supervision on the analog 2 wire interface GROUND START Sets the port to use FXO ground start signalling on the T span and ground start supervision on the analog 2 wire interface DPT Sets the port to use Dial Pulse signalling to terminate dialed numbers TX DB Sets the Tx direction transmit level points The transmission level is indicat ed in dBm Range is from 0 to 9 9 dBm Default is 6 0 RX DB Sets the Rx direction transmit level points The transmission level is indicat ed in dBm Range is from 0 to 9 9 dBm Default is 3 0 Svc MODE I
6. d on the Quad FXO Voice Module when it is inserted into an active TA 850 chassis The test verifies proper operation of critical cir cuits If the test is successful all four LEDs turn on in a predefined sequence the unit is placed in service and the LEDs then return to normal operation showing current status of the EXO Other tests conducted on the Quad FXO Voice Module are initiated via the screen menus and VT 100 terminal See Quad FXO Voice Module Test Options on page 3 4 for more information 61175407L1 Quad FXO Voice Module User Manual 3 1 Chapter 3 Operation METHODS OF OPERATION You can control and configure the Quad FXO Voice Module from the follow ing sources e The terminal menus allowing detailed configuration status and diag nostics e SNMP primarily for reporting alarm conditions and system status The remainder of this section describes the menu items presented when managing the Quad FXO Voice Module via the terminal menu Access the terminal menu using either a VT 100 terminal attached to the TA 850 Base Unit s control port or a Telnet session established through the Base Unit s Ethernet port The TA 850 User Manual provides detailed instructions on the operation of each of these management approaches The factory default password is PASSWORD It can be changed to a user specified password TERMINAL MENU STRUCTURE The TA 850 uses a hierarchical menu structure to provide access to all of its fe
7. defects during the warranty period Upon such notice ADTRAN will at its option either repair or replace the defective item If ADTRAN is unable in a reasonable time to repair or replace any equipment to a condition as warranted Customer is entitled to a full refund of the purchase price upon return of the equipment to ADTRAN This warranty applies only to the original purchaser and is not transferable without ADTRAN s express written permission This warranty be comes null and void if Customer modifies or alters the equipment in any way other than as specifically authorized by ADTRAN EXCEPT FOR THE LIMITED WARRANTY DESCRIBED ABOVE THE FOREGOING CONSTITUTES THE SOLE AND EXCLUSIVE REMEDY OF THE CUSTOMER AND THE EXCLUSIVE LIABILITY OF ADTRAN AND IS IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESSED OR IMPLIED ADTRAN SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES INCLUDING WITHOUT LIM ITATION ALL WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PUR POSE SOME STATES DO NOT ALLOW THE EXCLUSION OF IMPLIED WARRANTIES SO THIS EXCLUSION MAY NOT APPLY TO CUSTOMER In no event will ADTRAN or its suppliers be liable to Customer for any incidental special punitive exemplary or consequential damages experienced by either Customer or a third party including but not limited to loss of data or information loss of profits or loss of use ADTRAN is not liable for dam ages for any cause whatsoever whether based in contract tort or other
8. ding 6 Suite 690 Huntsville Alabama 35807 RMA
9. ed device s Complete installation of remaining modules and Base Unit as 6 specified in the Installation chapter of the TA 850 User Manual WIRING TA 850 A single 50 pin male amphenol connector on the rear of the TA 850 chassis provides the interconnect wiring for the four analog circuits on each access module Figure 2 1 shows the pinout connection Circuit 4 Circuit 3 Circuit 2 Circuit 1 Circuit 4 Circuit 3 Circuit 2 Circuit 1 Circuit 4 Circuit 3 Circuit 2 Circuit 1 Circuit 4 Circuit 3 Circuit 2 Circuit 1 Circuit 4 Circuit 3 Circuit 2 Circuit 1 Circuit 4 Circuit 3 Circuit 2 a 0104000 4010 el deel ll 0 05 040 2 0 a 10 ato 013 Circuit 1 50 PIN AMP RECEPTACLE Figure 2 1 Connector Pin Assignments 2 2 Quad FXO Voice Module User Manual 61175407L1 Chapter 3 Operation OVERVIEW LED Status TESTING Self Test Initiated Tests The Quad FXO Voice Module goes operational upon insertion into an active TA 750 850 1500 chassis Once a module is inserted the user must map an FXO port to a network port for proper operation Refer to the TA 850 User Manual Channel Bank chapter DSO mapping section for information After the initialization sequence faceplate LEDs show the status of the ana log service for each customer loop as follows Off On Hook Flashing Ringing On Off Hook Busy A self test is performe
10. m 2 1611 F 2 wire VF interface NEBS Level 3 and UL 1950 compliant e Extended temperature range of 40 to 65 C 1 2 Quad FXO Voice Module User Manual 61175407L1 Chapter 1 Introduction QUAD FXO VOICE MODULE SPECIFICATIONS The Quad FXO Voice Module conforms to the following specifications ELECTRICAL SPECIFICATIONS Power 6 Watts off hook Loop Current 23 mA nominal 20 mA minimum Loop Resistance 1200 ohms nominal 1650 ohms maximum 900 ohms 1350 ohms line 300 ohms phone Loop Length 16 kfeet Terminating Impedance User selectable 900 ohm 2 16uF 600 ohm 2 164 F 900 ohm and 600 ohm Return Loss 900 ohm 2 16uF ERL gt 28 dB SRL gt 20 dB Trans Hybrid Loss 900 ohm 2 16uF ERL gt 28 dB SRL gt 20 dB Longitudinal Balance 200 500 and 1000 Hz gt 58 dB min gt 63 dB avg 3000 Hz gt 53 dB min gt 58 dB avg Frequency Response 300 to 3400 Hz 0 5 and 1 0 dB Idle Channel Noise lt 20 dBrnC Signal to Distortion Ratio 0 to 30 dBm0 gt 33 dB 30 to 40 dBm0 gt 27 dB 40 to 45 dBm0 gt 22 dB PHYSICAL SPECIFICATIONS Dimensions 31 4 Hx10 D Weight 1 lb ENVIRONMENTAL SPECIFICATIONS Operating Temperature 40 to 64 C Storage Temperature 40 to 70 C Relative Humidity Up to 95 noncondensing Measured with 48 VDC input 20 mA loop current 61175407L1 Quad FXO Voice Module User Manual 1 3 Chapter 1 Introduction
11. nd receive signalling bits are shown in the STATUS menu of the Quad FXO module TA 850 FEATURES USED WITH QUAD FXO VOICE MODULE OPTIONS Factory Restore Two additional TA 850 menu items can operate in conjunction with the Quad FXO Voice Module FACTORY RESTORE and RUN SELFTEST You can restore the factory default settings for an Quad FXO Voice Module by pressing F while the cursor is over the SLT number this action restores the factory settings for all of the module options while the cursor is over the PRT number this action restores the factory settings for the port or while the cursor is over an individual field this action restores factory settings for the particular field only 3 4 Quad FXO Voice Module User Manual 61175407L1 Index Numerics 1004 Hz 0dbm0 tone generation test 3 4 C connectors 1 3 customer service iii D description 1 2 dial pulse signalling 3 3 digital net loopback test 3 4 DPT 3 3 F factory restore 3 4 features 1 2 TA 850 3 4 G ground start 3 3 Installing 2 1 installing Quad FXO module 2 1 introduction 1 1 L LEDs 3 1 loopstart 3 3 menu structure 3 2 terminal menu structure 3 2 menu options 3 3 mode 3 3 N network on hook off hook test 3 4 O operation 3 1 overview 1 1 operation 3 1 P power connection connection 2 2 prt 3 3 Q Quad FXO module description 1 2 features 1 2 installing 2 1 operation 3 1 overview 1 1 specifications 1 3
12. ndicates whether the module is IN SERVICE or OUT OF Svc This does not in dicate whether the port has been mapped For proper operation the port must be mapped using the DSO MAPS menu 61175407L1 Quad FXO Voice Module User Manual 3 3 Chapter 3 Operation QUAD FXO VOICE MODULE TEST OPTIONS PRT TEST DIGITAL NET LOOPBACK TEST NETWORK ON HOOK OFF Hook TEST 1004 HZ ODBMO TONE GENERATION TEST TEST STATUS Identifies the port involved To initiate a module test scroll to the TEST column and press Enter Options are detailed below The Digital Net Loopback Test is used to loop back DSO data coming from the network for each channel Received data is latched In on the appropriate receive time slot on the receive bus This data is then placed on the transmit bus in the unit s transmit time slot The Network On Hook Off Hook Test is used to test signaling sent to the network by the unit When On Hook Test is selected On Hook signaling is sent to the network When Off Hook Test is selected Off Hook signaling is sent to the network The customer loop is forced On Hook while this test is active The 1004 Hz OdbmO Tone Generation Test is used to send DRS signal on the receive path to the loop The loop receive level that should be received is de termined by the following equation Receive Level 0 dB Attenuation Tells whether a test is in progress QUAD FXO VOICE MODULE STATUS OPTIONS The transmit a
13. ntitled Digital Apparatus ICES 003 of the Department of Communications Cet appareil numerique respecte les limites de bruits radioelectriques applicables aux appareils nume riques de Class A prescrites dans la norme sur le materiel brouilleur Appareils Numeriques NMB 003 edictee par le Ministre des Communications Warranty and Customer Service ADTRAN will replace or repair this product within five years from the date of shipment if the product does not meet its published specification or if it fails while in service For detailed warranty repair and return information refer to the ADTRAN Equipment Warranty and Repair and Return Policy Proce dure see the last page of this manual A return material authorization RMA is required prior to returning equipment to ADTRAN For service RMA requests or more information see the last page of this manual for the toll free contact number Limited Product Warranty ADTRAN warrants that for five 5 years from the date of shipment to Customer all products manu factured by ADTRAN will be free from defects in materials and workmanship ADTRAN also warrants that products will conform to the applicable specifications and drawings for such products as con tained in the Product Manual or in ADTRAN s internal specifications and drawings for such products which may or may not be reflected in the Product Manual This warranty only applies if Customer gives ADTRAN written notice of
14. the Central Office switch ADRAR FXO 117540711 BUSY 10 20 30 10 Figure 1 1 Quad FXO Voice Module If TR 08 signaling format is not readily available at the CO switch both FXO and FXS access modules can be used for deployment The TA 850 at the CO will combine a number of analog lines and then multiplex them for T1 trans mission to the TA 850 at the customer premise 61175407L1 Quad FXO Voice Module User Manual 1 1 Chapter 1 Introduction Functional Description The Quad FXO Voice Module installs in any available option slot in the TA 850 chassis You can view the status of the module itself as well as the circuits to which it interfaces from the TA 850 front panel Additional status information is available via the terminal menus accessible through either a VT 100 terminal connected to the TA 850 control port or via a Telnet session established through the Base Unit s Ethernet port Features Features of the Quad FXO Voice Module include e Four voice ports e Automatic short loop provisioning e law encoding and decoding e Support for Ground start loop start and TR 08 signaling e Long loop capability 1200 ohms including telephone set 16 kfeet 24 AWG e Hot swappable e V 90 Modem compliant e Support for CLASS features such as Caller ID e Transmit attenuation setting of 0 to 9 dB e Receive attenuation setting of 0 to 9 dB e Selectable 600 ohm 900 ohm 600 ohm 2 16uF or 900 oh
15. wise in excess of the amount paid for the item Some states do not allow the limitation or exclusion of liability for incidental or con sequential damages so the above limitation or exclusion may not apply to Customer Table of Contents List EE vii Chapter 1 Tri trod erte e ans ao 1 1 Quad FXO Voice Module Overview cccccssssscessesscescssseseseseesccescessessecsecssesecssseseseseseseeseseceaeeaeecsecseesaeesaeeaes 1 1 Functional Descriptor las anna a une 1 2 A ianbu ale Blei hal nenanensieegehsahergeninshleiehsee 1 2 QUAD FXO Voice Module Specifications ENEE 1 3 Chapter 2 Installation Eed REENEN NEG 2 1 Before Installing the Quad FXO Voice Module NENNEN 2 1 Shipping Contents itt maana daiwa un a ioe sinh matin lan Sardines 2 1 Installing the Quad FXO Voice Module ue 2 1 WATS ee ails fesse cee alannah E SS re a NED 2 2 PAL BDO a Ee ee 2 2 Chapters Operation isidro A E A A ER naa aaa ada acid 3 1 DA A A FEES 3 1 SN EE 3 1 Testing EE 3 1 Self KE GENEE 3 1 Initi ted Tests SAS a a nee N Ee A a 3 1 Methods of Opera a Amann ts besessen At ddr 3 2 Terminal Ment Structure li a ii e e eg cals 3 2 Quad FXO Voice Module Menu Option 3 3 O 3 3 EE 3 3 IER EE 3 3 Ground Start er RE Rn ate asd AA een ernennen E Aa 3 3 DET Fie AENA AS EE EE EE 3 3 TX dB re esse ur ER es ne SR STREET RER 3 3 RX EE 3 3 SEMA A Ee 3 3 Quad FXO Voice Module Test Options EE 3 4 Ee e EE 3 4 Test ur Were en e N ci Tesista 3 4 Digital Net