1. T 5 gt ps 5e X i gt ae aay i ma E he a va 7 ma we AY i sxe ee e AO g Description As the core communications network migrates from TDM to IP the Loop IP6763 TDMoEthernet Aggregator is a cost effective choice to allows operators to transport up to 32 E1 T1 STM 1 0C3 STM 4 OC12 plus Ethernet signals over an IP network The Loop IP6763 TDMoEthernet provides flexible solutions with hot swappable STM 1 OC3 and STM 4 0OC12 plug in card The IP network is connected through dual WAN ports The WAN interface consists of dual combo Gigabit Ethernet ports with link aggregation On the user side the TDM ports can be multiple E1 T1 STM 1 OC3 and STM 4 0C12 each with timing preserved The LAN interface is 3 x 10 100 1000 BaseT Ethernet ports Management choices include console port Ethernet port and SNMP port for communication with remote management centers For the transport of TDM signals Jitter and Wander adheres to G 823 Traffic 1ppm to provide excellent clock accuracy Features 1U height ETSI shelf full front access Aggregate ports e 2x WAN ports combo Gigabit Ethernet GbE with SFP and RJ45 housing e Protection e 802 3ad Link Aggregation Tributary ports e Hot swappable plug in card type e 2 Dual STM 1 OC3 cards or e 1 Dual STM 4 OC12 card with 1 1 protection e LAN interface 3 x 10 100 1000 BT Ethernet ports auto negotiation e E1 T1 Interface 8 E1
2. T1 16 E1 T1 32 E1 T1 e Hot swappable Power e Dual 48Vdc plug in module 36 to 72 Vdc Loop IP6763 TDMoEthernet Aggregator Bridging amp Switching e Jumblo frame up to 13K bytes e Max 4K VLAN e Assign VLAN based on MAC IP or protocol e VLAN based packet filtering e Translation on ingress and egress e Qin Q add remove and translate both S VLAN and C VLAN QoS e 8 priority queues port e User config CoS and DiffServ ToS in outgoing IP frame e DSCP mapping e Strict priority WRR WDRR for queue shaping e RED and WRED for queue management Pseudo Wire PW e Max 1024 pseudo wires e Each PW can be assigned a separate VLAN e Point to point and point to multi point Support 802 1d MAC learning max 32K Support 803 3x Flow control on input ports Support 802 1D STP 802 1s MSTP 802 1w RSTP Support IGMP Snooping RFC 2236 Storm control packet based or byte based Ingress rate limit per port from 8k bps to 1G bps Link Level OAM 802 3ah Clause 57 Service Level OAM 802 1ag ITU Y 1731 Support IPv4 Routing amp IPv6 Routing Support 2 SNTP Timing References Support MPLS TP Alarm Relay and ACO Alarm Cutoff button Jitter and Wander e PPM per G 823 Traffic 1ppm Management port and interface e Console port VT100 menu driven e SNMP port v1 v3 e SSH e Telnet via SNMP port e In band management through Ethernet WAN ports A VLAN port e Any one of the DCC channels SAToP RFC 4553 SONET SDH CEP RFC 4
3. 100 1000 BaseT IEEE802 3 Auto negotiation 10 100 1000M Auto MDI MDIX Full or half duplex RJ45 802 1q e VLAN support Max 4k Assign VLAN based on MAG IP protocol or flow VLAN based packet filtering Translation on ingress and egress Q in Q add remove and translate both S VLAN and C VLAN 802 1p Packet classification with 8 queues port User config CoS and DiffServ ToS in outgoing IP frame DSCP mapping Strict priority WRR WDRR for queue shaping RED and WRED for queue management 802 1d e MAC learning max 32k entries Flow Control Link Aggregation Spanning Tree Protocol IGMP Snooping Ingress Rate Limit IPv4 IPv6 SNMP Ethernet Number of Port Ethernet Functions Connector 802 3x 802 1ad 802 1s MSTP 802 1w RSTP support and 802 1d STP Compatibility RFC2236 e a network switch to listen in on the IGMP conversation between hosts and routers e per port from 100kbps to 1 Gbps e RIP1 RIP2 OSPF and Static Route 10 100 1000 BaseT IEEE802 3 Auto negotiation 10 100 1000M Auto MDI MDIX Full or half duplex RJ45 Clock Source for System and Port Primary Secondary Clock External Clock Input Signal Output Signal Connector Alarm Input Output Input port Internal Resistance Activation Current Deactivation Current Connector Output port Initial Insul Resist Max Current Network Management Console Port Electrical Protocol Connector In band Management Interface
4. 842 CESoPSN RFC 5086 MEF 8 TDMoIP RFC 5087 HDLCoPSN RFC 5087 4618 Compliance ROHS Compliance Future option Ordering Information To specify options choose from the list below Note RoHS compliant units are identified by the letter G appearing immediately at the end of ordering code Model Description Note Main Unit Loop IP6763 1UE PPM s1 s2 1U height ETSI chassis with G 823 traffic with dual Combo e Where s1 s2 pp1 pp2 pp1 pp2 add1 G Gigabit Ethernet GbE card for WAN port SFP optical module and add1 are defined in the not included 3 LAN and 1 SNMP tables below Plug in Modules Loop IP6763 2B155 Dual STM 1 OC3 card Loop IP6763 2B622 Dual STM 4 OC12 card Power Plug in Power Module Loop IP6763 S SD48 G Single 48 Vdc power plug in module 36 to 72 Vdc FAN Loop IP6763 FANA G Fan board with fan power and fan fail LED indication Filter Loop IP6763 FIL G Air filter rack for IP6768 air filter included Accessories User s Manual Loop IP6763 UM Firmware Upgrade Loop IP6763 FWUPGR Firmware Upgrade Customers who desire to have a firmware upgrade after their warranty has expired can purchase this option This will upgrade the firmware to the most current version and provide an additional 12 months of software repair and patches on existing functionality as necessary User s Manual paper hard copy optional A CD version of the manual is already included as standard equipment SFP Opti
5. L2 Protocol Performance monitors Performance Store Performance Reports Alarm History Alarm Queue Internal STM 1 WAN port PW E1 T1 2 048 MHz 1 544 MHz user selectable E1 T1 2 048 MHz 1 544 MHz user selectable RJ48C 2 048MHz 1 544MHz 1K 3mA 1 5mA RJ45 4 Min 1000 ohm at 500VDC 1A for 30Vdc 0 3A for 125 Vac SNMP Port RS232 interface Protocol Telnet VT100 SSH and Embedded SNMP Menu driven VT 100 Connector RJ45 terminal DB9 female and DCE DCC Data Communication Channel of SDH SONET HDLC Encap Telnet VT100 SSH and Embedded SNMP The last 24 hours performance in 15 minute intervals Date amp Time Error Block EB Background Block Error BBE Error Second ES Burst Error Second BES Severe Error Second SES Unavailable Second UAS System Alarm Alarm Cut Off Power Loss Unegp Fan Fail Overheat System Clock Loss Log on and Log off Optical Port Uneqp Ethernet Link Card In Card Out Card Type Mismatch Card Port Number Mismatch Card Fail Card Registration MSP Switch SFP Tx Fail SFP Rx Fail SFP Temperature SDH SONET SDH Line PI LOS RS LOF RS TIM RS BIP UAS MS SD MS SF Alarm MS AIS MS RDI MS BIP UAS MS REI UAS Ho Path AU LOP AU AIS HP SD HP SF HP TIM HP UNEQ HP PLM HP RDI S HP RDI C HP RDI P HP BIP UAS HP REI UAS LOM Lo Path TU LOP TU AIS LP SD LP SF SONET Line LOS PI LOF S TIM S BIP S UAS SD L SF L AIS L RDI L BIP L UAS REI L UAS STS Pa
6. S GbE FE FastEthemet 0 E Fast Ethernet 2 E1 FE Fast Ethernet gt Extension of SDH SONET Trunks through IP MPLS Corporate Head Quarter IP MPLS Branch Office lt LOOP TELECOMMUNICATION INTERNATIONAL INC mm PATA VA LoopTelecom com ISO 900 1MSO 14001 Worldwide Taipei Taiwan North America Tianjin China 8F No 8 Hsin Ann Road 6F No 36 Alley 38 Lane 358 8 Carrick Road No 240 Baidi Road Science Based Industrial Park Rueiguang Road Palm Beach Gardens Nankai District Hsinchu Taiwan 30078 Neihu Taiwan 11492 Florida 33418 U S A Tianjin 300192 China Tel 886 3 578 7696 Tel 886 2 2659 0399 Tel 1 561 627 7947 Tel 86 22 8789 4027 Fax 886 3 564 6272 Fax 886 2 2659 2325 Fax 1 561 627 6615 Fax 86 22 8789 0344 www Loop Telecom com michael_tzeng loop com tw jimber561 aol com wym loop tj com sales loop com tw 2012 Loop Telecommunication International Inc All Rights Reserved Version 1 21 MAY 2012 Subject to change without notice
7. cal Modules Please place your order using the 5 digit alohanumeric codes listed in the separate SFP Optical Module Brochure Ear Mounts 19 23 ear mounts A pair of 19 23 ear mounts is supplied as part of standard e For other sizes please package contact your nearest Loop s sales representative Blank Panel 30 001757 A00LF The blank panel for power 30 001 758 A00LF The blank panel for optical Conversion Panels Loop ACC P 1SCSI 16RJ G One SCSI to sixteen RJ 1U height without cable Loop ACC P 1SCSI 16BNC G One SCSI to sixteen BNC 1 5U height without cable Conversion Cables Loop ACC CAB SCSI68M 200 e Used for all conversion 4SCSI68M G SCSI68 Male to one SCSI68 Male Length 200cm panels m Where s1 is used to select plug in module for slot 1 If this module is not required leave this field blank s1 Description Note 2B155 Dual STM 1 OC3 card m Where s2 is used to select plug in module for slot 2 If this module is not required leave this field blank s2 Description Note 2B155 Dual STM 1 OC3 card Maximum 2 dual STM 1 0C3 2B622 Dual STM 4 0C12 card cards allowed Maximum 1 dual STM 4 0C12 card allowed with 1 1 protection STM 4 OC12 card is future option m Where pp1 and pp2 are used to select the power module If the second plug in power module is not required leave this field blank pp Description SD48 Single 48Vdc power plug in module 36 to 72 Vdc Note For redundancy p
8. th LOP P AIS P SD P SF P TIM P UNEQ P PLM P RDI S P RDI C P RDI P P BIP P UAS REI P UAS LOM VT Path LOP V AIS V SD V SF V Multiplexing LOF AIS UAS RAI YEL E1 T1 E1 T1 Alarm LOS LOF AIS UAS RAI YEL Contains up to 200 alarm records of latest alarm types alarm severity date and time Diagnostics test SDH SONET Loopback Local loopback and line loopback Diagnostics test T1 E1 Loopback Remote loopback and local loopback Power 48 Vdc Module 36 to 72 Vdc Power Consumption lt 65 W for 1U height Physical and Environmental Dimensions 438 mm x 44 mm x 225 5 mm WxHxD Net Weight 4 0 Kg Temperature 0 to 50 C operation Humidity 5 95 RH non condensing Mounting Desk top stackable rack mount Certification EMC EN55022 Class A EN55024 FCC15 Safety EN60950 1 Standards and Compliance ITU T G 703 G 704 G 823 IEEE 802 3 802 3u 802 3z 802 3X 802 1q 802 1ad IETF RFC4553 SAToP RFC4842 SONET SDH CEP RFC5086 CESoPSN RFC5087 TDMoIP RFC5087 4618 HDLCoPSN MEF 8 Future option Panel Views 2 DC Power Supplies 8 16 32 x E1 T1 Console port Alarm Input Output 2 Dual STM 1 OC3 cards 3 10 100 1000 Clock Input Output Air Filter EON agi SNMP Port 2 GbE WAN Ports Fan Application Illustrations gt Transport of E1 T1 amp LAN through IP MPLS 4 E1 FE Fast Ethernet FE Fast Ethernet lt lt i _PMPLS aa na ee GbE aa ok gy P
9. urpose ordering a second plug in module will provide dual power E Where add1 is manufacture option used to select a daughter card If this is not required leave this field blank future option add1 8TE 8 E1 T1 card 16TE 16 E1 T1 card 32TE 32 E1 T1 card Description Note Support E1 75 1200hm and T1 100ohm Please order separately for conversion panel Loop IP6763 Product Specifications SFP Optical Module Characteristic Please refer to SFP optical module brochure for detail Aggregate Combo Gigabit Ethernet GbE Interface Number of Ports Speed Connector 2 RJ45 10 100 1000 Mbps SFP 100 1000 Mbps Auto negotiation 10 100 1000M Auto MDI MDIX Full or half duplex RJ45 for twisted pair GbE SFP for optical GbE auto detection E1 Tributary Interface E1 T1 Software selectable Line Rate Line Code Framing Output Signal Input Signal Jitter Connector 2 048M bps 50 ppm AMI HDB3 ITU G 704 CRC on off CAS on off unframed ITU G 703 ITU G 703 ITU G823 SCSI II 68 pin T1 Tributary Interface E1 T1 Software selectable Line Rate Line Code Framing Output Signal Input Signal Pulse Template Connector LAN Ethernet Interface Number of Port Ethernet Functions Connector L2 Switch VLAN QoS MAC 1 544M bps 32 ppm AMI B8ZS selectable D4 ESF ESF amp T1 403 OFF clear channel DS1 with LBO Setting DS1 Per AT amp T TR 62411 SCSI II 68 pin 3 10
Download Pdf Manuals
Related Search
Related Contents
ModelSim User's Manual - Electronics and Computer Science Datapanel 40/45, 60/65 & 85 Manual del usuario GFK-1806A-SP Rapport de stage technique la GPEC Kanex RGBRLHD video converter Klein Tools VDV526-052 Use and Care Manual Fecha de publicación: 31 de julio de 2014 NO. NOMBRE DEL Control unit pCO3 Manual de Instruções PRO MIXER DJX700 Com a Copyright © All rights reserved.