Home
Basic DX - VMCare - With the greatest care for Care
Contents
1. Basic DX Static Anti Decubitus Overlay System USER MANUAL hi Prius Caremed Supply Inc 7F No 2 Lane 235 Bao Chiao Rd Xin Tien City Taipei 231 Taiwan Tel 886 2 2917 9808 Fax 886 2 2918 6505 ee Sh aN Contents The Purpose of this Manual Product Description Technical NI Nu Co a tee ce Instruction for Proper Use Gleanna is mueriiasmnrtn on dcktuumeanenen ean ataar Storage and Care wwwwwwwwmmmmmemimwimamaa Maintenance and Troubleshooting Warning Connect the Master Control unit to a 100 240 volt to a power source Keep the pump and mattress away from open flame Keep the mattress away from sharp objects Do not place a heating device close to the mattress system Caution The Alternating System should always be used in accordance with your Institutions pressure care guidelines Re positioning of the patient is always recommended when using an Alternating Pressure Air Mattress APAM The Control unit can only be repaired by an authorized technician Do not drop the control unit Operation Temp 15 C 40 C R H 30 75 Yo 1 The Purpose of this Manual This operation manual is mainly focused on the set up cleaning and routine maintenance of the Basic DX Air Pump with Mattress overlay System We recommend you keeping this manual handy to answer most of the question related to the system 2 Product description intended use The Basic DX Air Pum
2. e foot side of the bed Hang the Air Pump on the foot side board and attach mattress air tube onto air 2 3 socket located on the side of the Air Pump Ensure the air hose is not kinked Plug the power cord of control unit into a socket Product function illustrate gt Power Switch e The switch is on the left side of the control unit Pump e Turn on I off o the power the control unit Pump will start stop operation gt Comfort Level e Turn the pressure control dial to adjust the comfort level gt Indicator Light LOW NORMAL PRESSURE Indicator lt COMFORT LEVEL Pressure Control Dial The LOW PRESSURE indicator light will be illuminated when the pump starts working and the air pressure of the mattress is not yet reach the setting level e The NORMAL indicator light will be illuminated when the air pressure reach the setting level 5 Cleaning Control unit AirPump SWITCH OFF THE ELECTRICAL SUPPLY TO THE PUMP AND DISCONNECT THE POWER CORD FROM THE MAIN SUPPLY BEFORE CLEANING AND INSPECTION Control unit AirPump should be cleaned weekly using a damp soft cloth and mild detergent It s case is manufactured from ABS plastic can be wiped down with cleaning solution Do not use phenol based cleaning solution Mattress Overlay Mattress can be wiped down with cleaning solution 6 Storage and Care Control unit AirPump Ch
3. eck the power cord and plug for abrasions or excessive wear Plug in the unit and verify air flows from the units hose connection ports Place in plastic bag for storage Mattress Overlay Disconnect the air feed tubes After the air is released mattress can be folded Place in plastic bag for storage It is recommended the following guidelines are used whenever this system is being stored or transported another location Temperature limitations 14 F 10 C 104 F 40 C Relative Humidity 30 95 7 Maintenance amp Troubleshooting No daily maintenance is required It is intended this equipment should only be serviced by properly qualified authorized technical personnel Problem Troubleshooting Responce The control unitis 1 Check for power cord and power 1 It there is no wrong on power not working voltage cord amp power voltage contact Customer service for help The mattress is not 1 Is the air hose kinked 1 Check out air hose inflating while 2 Is the air cell broken or damaged 2 Replace new mattress control unit is 3 Is there any air leak between mattress 3 Replace new mattress or fix it working and control unit Air Pump X Prius Caremed Supply Inc 7F No 2 Lane 235 Bao Chiao Rd Xin Tien City Taipei 231 Taiwan Tel 886 2 2917 9808 Fax 886 2 2918 6505
4. p with Mattress overlay System is a static overlay system provides safe support and great comfort to patients Easy to set up and suitable for use in the community and nursing home environment Control unit AirPump Features The control unit AirPump is user friendly designed and most of the functions are self explained Adjustable comfort range with easy operating and control knob 0 Convenient hooks secure to most bed frames Mattress Features One piece design for maximum pressure distribution The overlay mattress can easily attach to existing hospital bed mattress 3 Technical Data Control unit AirPump Model name BASIC DX Model no M2 Part no FC PHE0005 Size mm 120 L x95 W x265 H mm Weight Kg 1 6 kg Cycle Time min 12 min Min Max Pressure 16 32 mmHg 6 mmHg Max Flow rate 24 5 L min Rated Voltage AC 220 240 volt Max Current 0 1A Fuse Rating T1AH 250V Rated Frequency 50 Hz Protection Type Class II Type BF gt Not AP or APG Type o Mode of Operation Continuous Mattress Overlay Mattress type 3 one piece bubble pad Part no FM PHE0001 Size mm 200cm L x 90cm W x 8cm H Weight Kg 2 Kg Cells Material PVC Weight capacity kg 100 kg 4 SET UP for Air Pump with Mattress overlay System 1 Place the mattress directly onto the existing mattress bed and to ensure that the air hose is at th
Download Pdf Manuals
Related Search
Related Contents
User Manual Manual del Propietario openFT V11.0 for Unix Systems Wayne-Dalton 3966 User's Manual Life Fitness TREADMILL T3 User's Manual M3GPS X8.5 User Manual 1 - Forth Interest Group Poulan 966557801 Chainsaw User Manual Copyright © All rights reserved.
Failed to retrieve file