Home
User Manual
Contents
1. Make sure the distance between the stove top and the bottom of the hood is within 27 and 33 in distance Due to different ceiling height configura tions recommended height may not be applicable Reduce the number of elbows and length of duct work Check if all joints are properly connected sealed and taped Make sure the power is on high speed for heavy cooking 16 USE amp CARE INFORMATION Operations Read and understand all instructions and warnings in this manual before operating the appliance Save these instructions for future reference Always leave safety grills and filters in place Without these components operating blowers could catch on to hair fingers and loose clothing NEVER dispose cigarette ashes ignitable substances or any foreign objects into blowers NEVER leave cooking unattended When frying oil in the pan can easily overheat and catch fire The risk of self combustion 1s higher when the oil has been used several times NEVER cook on open flames under the range hood Check deep fryers during use Superheated oil may be flammable Cleaning The saturation of greasy residue in the blower and filters may cause increased inflammability Keep unit clean and free of grease and residue build up at all times to prevent possible fires FILTERS MUST BE CLEANED PERIODICALLY AND FREE FROM ACCUMULATION OF COOKING RESIDUE see cleaning instructions on Page 15 Old and worn filters must be replaced
2. USA Canada LED 2 WATTS Make sure the range hood is unplugged or turn OFF breaker Make sure the lights are cool to touch carefully align the arrow on the inner ring with the arrow on the outer ring where says OPEN The inner ring will loosen and the light bulb will be available for removal Install a new halogen light bulb and reverse the steps Turn ON breaker and range hood to test for operation 18 SPECIFICATION Motor Input Power Ampere Levels Of Speed Control 4 Levels Q L M H 280CFM 460CFM 670CFM 900CFM Q L M H 1 2Sone 43dB 2 8Sone 55dB 5 0Sone 63dB Noise Level 7 0Sone 68dB LM NOTE Specification subject to change without notice please contact your local reseller for details REPLACING THE LIGHT BULB 1 Make sure the range hood is unplugged or turn OFF breaker 2 Use the small flat crew driver to lift any where around the outsider ring as show in below picture Arrow 3 Install new light bulb 4 Put back the light set by press it in 5 Turn ON breaker and range hood to test for operation NOTE Make sure the lights are cool to touch P ax 3 1 32 sae The Advanced Range Hoods XtremeAir Hood Five 10 Years Motor Limited Warranty XtremeAir USA LLC hereunder called The Company provides a warranty that its products are free from defects in workmanship and materials for a period of two 2 year from the date of original purchase During that time period The Compan
3. This range hood is equipped with remote control and smoke sensor that will self calibrate within 5 seconds when the range hood 1s first electrically activated Self calibration will be set when the range hood beeps LCD panel will turn off automatically after a period of inactivity 13 A Activating Normal Blower Function e While the range hood 1s off press Increase or Decrease button to start the blower o O NOTE Press or button to increase or decrease blower speed as indicated in LCD panel 00 blower off F quiet speed F2 low speed F3 medium speed F4 high speed Decrease Increase B Activating Light Function amp Press Light button to turn the lights on or off Light C Activating Power Off Delay Function 1 While the range hood is on and the blower is running in normal mode press Power Off Delay button to activate delay off timer 2 Adjust to desired period of delay off timer by pressing or 4 button 1 15 minutes Power Off Timer beings to countdown immediately when it reaches 0 the blower will shut off Delay D Activating Smoke Detector Function e While the machine is off press Auto Function button to activate the smoke detector auto function mode NOTE this function is only work when there s a lot of smoke Auto Function E Remote Control Sensor 1 Remote control sensor receives infrared IR signal from the remote control The maximum distance for IR data transmis
4. immediately DO NOT operate blowers when filters are removed Never disassemble parts to clean without proper instructions Disassembly is recommended to be performed by qualified personnel only Read and understand all instructions and warnings in this manual before proceeding 17 MAINTENANCE SAFETY WARNING Never put your hand into area housing the fan while the fan 1s operating For optimal operation clean range hood and all baffle spacer filter grease tunnel oil container regularly Regular care will help preserve the appearance of the range hood Cleaning Exterior surfaces e Clean periodically with hot soapy water and clean cotton cloth Do not use corrosive or abrasive detergent e g Comet Power Scrub EZ Off oven cleaner or steel wool scoring pads which will scratch and damage the stainless steel surface For heavier soil use liquid degrease such as Formula 409 or Fantastic brand cleaner e If hood looks splotchy stainless steel hood use a stainless steel cleaner to clean the surface of the hood Avoid getting cleaning solution onto or into the control panel Follow directions of the stainless steel cleaner CAUTION Do not leave on too long as this may cause damage to hood finish Use soft towel to wipe off the cleaning solution gently rub off any stubborn spots Use dry soft towel to dry the hood e After cleaning you may use non abrasive stainless steel polish such as 3M or ZEP to polish and buff o
5. make sure that the support system or framework being used is stable and secure in the wall Ep cd Me O 4 PX01 PX02 PX03 PX04 ra 8 5 8 8 5 8 8 5 8 8 5 8 B 15 28 to 33 15 28 to 33 151 2 28 to 33 15 28 to 33 For Example if 30 inch is the distance from cook top to bottom of hood for PX02 model so B 15 30 45 A Horizontal distance of 2 hanging screws B Vertical distance from cook top to hanging screws Note 28 33 is a recommendation height range from cook top to bottom of hood Attach the hood mounting bracket to the back of the hood with six screws as shown in Figure 1 For Model PX02 ONLY 4 Align hood mounting bracket to the two 2 screws on the wall and hook hood body into place as shown in Figure 2 and Figure 3 Tighten screws to secure hood to the wall Make sure the hood body is perfectly horizontal level 5 6 For safety purpose pre drilled mounting holes are provided through the back of the hood For a more secure installation use as many mounting holes as needed to secure from the inside of hood Use 6 round steel pipe follow building codes in your area to connect the exhaust on the hood to the duct work above Use silver tape or duct tape to make all joints secure and air tight Refer to Figure 4 LE Figure 4 7 SAFETY WARNING Risk of electrical shock This range hood must be properly grounded Make sure this is done by qualified electr
6. the local code authorities Sufficient air is needed for proper combustion and exhausting of gases through the duct to prevent back drafting Clean grease laden surfaces frequently To reduce the risk of fire and to disperse air properly make sure to vent air outside DO NOT vent exhaust into spaces between walls crawl spaces ceiling attics or garages When cutting or drilling into wall or ceiling be careful not to damage electrical wiring or other hidden utilities All electrical wiring must be properly installed insulated and grounded Before servicing or cleaning unit switch power OFF at service panel and lock service panel to prevent power from being switched ON accidentally Use this unit only in the manner intended by the manufacturer If you have questions contact the vendor WARNING To reduce the risk of a stove top grease fire l Always turn range hood ON when cooking at high heat or when cooking flaming foods 2 Use high settings on cooking range only when necessary a e Never leave surface units unattended at high settings Boil over cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings Keep all fan baffle spaces filter grease tunnel oil container and grease laden surfaces clean Grease should not be allowed to accumulate on fan baffle spaces filter grease tunnel and oil container Clean ventilating fan frequently Always use appropriate cookware and utens
7. P Gar 30 AU The Advanced Range Hoods INSTALLATION GUIDE amp USER S MANUAL PRO X SERIES Model PX01 PX02 PX03 PX04 Wall Mount Range Hood For residential use only READ AND SAVE THESE INSTRUCTIONS www XtremeAirUsa com Page 1 The manufacturer disclaims all liability for any damage or injury caused as a result of not following instructions for installation contained in the following text The range hood uses 120V 60Hz TABLE OF CONTENTS e Important Safety Note ccccoooonnccncnonoccnnnnnonnnnnnnnnnnnoos 3 4 s Pars Suppl 5 e Overall Dimensions DiagramM ooocccnnconcnnnnnnncnnnnnnnnos 6 TOOL AA amate sses susc a OscO Reus San 7 a Venns Me modi 7 e Mount heights amp clearance oooooccnncococnnnnncnnnnnnnnnnnnss 8 e Venting requirements aliada 8 amp Electrical require melts osea seca rt a 9 o Installation iara 10 13 e Range hood Opera Sarai ds 13 15 Troubleshooting ra 16 Se and Care mlortmallOB id 17 Oe AISA CS NE E 18 O DPC CIC AUIOMS rior 19 Replacine list DU D iita iei iubent oto a 19 e Warranty amp Customer Support eeeeeeeeeeee 20 www XtremeAirUsa com Page 2 J IMPORTANT SAFETY NOTICE Read all Instructions before Installing amp operating this range hood The installation in this manual is intended for qualified installers service technicians or persons with similar qualified background Installation and electrical wiring mu
8. ed Install as far away from opening and as far apart between 2 as possible If available also refer to stove top manufacturer s height clearance requirements and recommended hood mounting height above range The size of the vent should be uniform Use no more than three 90 elbows Make sure there is a minimum of 24 61 cm of straight vent between the elbows if more than one elbow is used DO NOT install two elbows together The vent system must have a damper If roof or wall cap has a damper DO NOT use damper if supplied on top of the range hood www XtremeAirUsa com Page 8 ELECTRICAL REQUIREMENTS IMPORTANT Observe all governing building codes and city ordinances Please consult with a qualified electrician for 220 Volt 50 Hz voltage It is the customer s responsibility To contact a qualified electrical installer To assure that the electrical installation 1s adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA Standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M9 latest edition and all local codes and ordinances If codes permit and a separate ground wire is used it is recommended that a qualified electrician determine that the ground path is adequate A 120 Volt 60 Hz AC only fused electrical supply is required on a separate 15 amp circuit fused on both sides of the line IMPORTANT Save this Installation Guide for electrical i
9. ician in accordance with all applicable national and local electrical codes Before connecting wires switch power off at service panel and lock service panel to prevent power from being switched on accidentally Connect the range hood to a designated standard outlet please refer the product label for the suitable voltage of this unit or cut off the plug and connect three wires black white and green to house wires and cap with wire connectors Connect according to Ari Colors 1 e black to black white to white and green to green Store excess wires in the wiring box Install both chimneys and tighten screws to secure the lower chimney to the range hood as shown in Figure 6 12 To avoid scratching the chimney extend the upper chimney slowly and carefully to the chimney mounting bracket and tighten screws as shown in Figure 7 Install baffle filters refer to Figure 8 for the following three steps 1 Angle baffle filter toward back of hood 2 Slide the knob toward the metal filter handle and push up 3 Release the knob until it fits into resting positions 12 Repeat step 11 to install all baffle filters 13 Turn power ON in control panel Check all lights and fan operations 14 Make sure to leave this Installation Guide for the homeowner RANGE HOOD OPERATION For PX02 Model Only LCD Panel Light Decrease Poxwer Off Increase Delay l Remote Control Auto Function Sensor Control Panel for P02 model Note
10. ils size Always use cookware appropriate for the size of the surface element WARNING To reduce the risk of injury to persons in the event of a stove top grease fire l SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn OFF the burner BE CAREFUL TO PREVENT BURNS NEVER PICK UP A FLAMING PAN you may be burned KEEP FLAMMABLE OR COMBUSTIBLE MATERIAL AWAY FROM FLAMES If the flames DO NOT go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT or dial your local emergency service immediately www XtremeAirUsa com Page 3 IMPORTANT SAFETY NOTICE Continue DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result Use an extinguisher ONLY if You know you have a Class A B C extinguisher and you already know how to operate it The fire is small and contained in the area where it is started The fire department is being called You can fight the fire with your back to an exit e e wn WARNING To reduce the risk of injury to persons in the event of a gas leaks 1 Extinguish any open flame 2 DO NOT turn on the range hood fan or any type of ventilator 3 DO NOT turn on the lights or any type of appliance 4 Open all doors and windows to disperse the gas If you still smell gas call the gas company and fire department or dial your local emergency service immediately Your safety and the safety of others are very important We have provided many
11. important safety messages in this manual and on your appliance Always read and obey all safety messages All safety messages will tell you what the potential hazard is teH yeu how to reduce the chance of injury and tell yeu what can happen if the instructions are not followed This 1s the safety alert symbol This symbol alerts you to potential hazards that can hurt you and others All safety messages will follow the safety alert symbol and the word WARNING AWARNING The manufacturer and or distributor reseller decline all responsibility in the event of failure to observe the instructions provided for installation maintenance and suitable use of the product The manufacturer and or distributor reseller shall NOT be responsible for any injury due to negligence and the warranty of the unit shall automatically be voided due to failure to observe proper safety and installation procedures The manufacturer and or distributor reseller will not be held responsible for any damages to personal property or real estate or any bodily injuries whether caused directly or indirectly by the range hood www XtremeAirUsa com Page 4 PART SUPPLIED Notice 1 Remove the range hood from the carton packaging and place on a flat surface for assembly 2 Check to ensure there are no missing parts including mounting hardware 3 DO NOT remove the plastic covering on the duct covers at this time as it protects the duct cover from scratches during installa
12. nspector s use DO NOT ground to a gas pipe Check with a qualified electrician if you are not sure that the range hood is properly grounded DO NOT have a fuse in the neutral or ground circuit The range hood must be connected with copper wire plug only The range hood should be connected directly to the fused disconnect or circuit breaker box through flexible armored or non metallic sheathed copper cable A U L or C S A listed strain relief must be provided at each end of the power supply cable Wire sizes copper wire only and connections must conform to the rating of the appliance as specified on the model serial rating label Wire sizes must conform to the requirements of the National Electrical Code ANSI NFPA 70 latest edition or CSA Standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances A U L or C S A listed conduit connector must be provided at each end of the power supply cable at the range hood and at the junction box ELECTRICAL DIAGRAM Model PX01 PX03 PX04 Model PX02 INSTALLATION AWARNING AWARNING AAWARNING 1 22 WARNING Excessive Weight Severe Injury Severe Inj u ry is i Do nel perfor service en an electrically live s s 1 A y system Disconnect the main electrical Require three or more person to move and Hood may have very shape edges Please wear Rotating fan can cause s supply before servicing is
13. r will begin to countdown when it reaches zero the blower motor will shut down TROUBLE SHOOTING 1 If the range hood or lights does not operate after installation 2 The range hood vibrates when the blower is On 3 The blower or fan seems weak 4 The lights work but the blower is not spinning at all is stuck or is rattling 5 The hood is not venting out properly Check if the range hood has been plugged in make sure that all power has been turned back ON the fuse is not blown and all electrical wiring is properly connected Swap out light assembly to working ones to detere mine whether it is caused by defective bulbs See replacing the light bulbs on Page 17 The range hood might not have been secured prop erly on to the ceiling or wall Check if the motor is secured in place If not then tighten the motor in place Check if the blower wheel is a damaged Check that the duct sized used is at least 6 or 3 1 4 x 10 Range hood WILL NOT function efficiently with insufficient duct size For example 7 duct over 6 hole and loosely secured Check if duct is clogged or if damper unit half cir cular flapper is not installed correctly or opening properly A tight mesh on a side wall cap unit might also cause restriction to the air flow The blower might be jammed or scraping the bot tom due to shipping damage Please contact us im mediately The motor is defective possibly seized change the motor
14. ranty services repair or any other inquiry CONTACT US XtremeAir USA LLC 309 N Harbor blvd Santa Ana CA 92703 USA Tel 714 554 9000 Email SupportO XtremeAirUSA com Website www XtremeAirUsa com DISCLAIMERS XtremeAir USA LLC shall not be responsible for loss of use or other incidental consequential costs expenses or damages which may occur Under no circumstances shall XtremeAir USA LLC or any of its representatives be held liable for injury to any person or damage to any property however arising This warranty gives you specific legal rights and you may have other rights which vary from state to state All rights reserved to XtremeAir USA LLC 20
15. s ON OFF lights 8 Indicates the accumulated time the system is running 9 Indicates the length of time left for delay off function 10 Lights up when auto shutdown delay timer function is on A Adjusting the blower motor speed l Press 1 Power button once to turn on the system The Blower Power Indicator icon flashes showing that the blower motor 1s ready 2 Decrease Value button will decrease the speed of the blower motor from 4 to 1 strongest to quietest Increase Value button will increase the speed of the blower motor from 1 to 4 quietest to strongest Press Power button once to turn off the system Note The system saves user configurations settings such as light timer and blower motor speed will remain the same the next time it is turned on B To turn the light on 1 Press Light button once to turn on the lights and once again to turn off the lights C Adjusting the timer function 1 While the blower motor is not running press and hold Decrease Value button over 3 seconds to enter timer mode 15 2 Adjust to desired period of delay off timer by pressing Increase Value or Decrease Value button minimum 1 minute to maximum 15 minutes This setting will be saved immediately D Activating the timer function 1 While the blower motor is running press and hold Power button for over 3 seconds to activate delay off timer Power off delay indicator will lit up and power off delay digital time
16. sion is 3 meter and requires direct line of sight The transmission distance may vary depending on temperature and remote control battery condition NOTE se oiu l Light settings are independent from other settings including power off delay and lights have to be manually turned on or off 2 The system saves user configurations settings such as light timer and blower motor speed will remain the same the next time it is turned on 14 For Model PX01 PX03 PX04 PX04 I Control Panel Layout and Buttons YO n j Bw 1 Power Light 6 2 Decrease Value Increase Value 3 Blower Power Indicator Power On Elapsed Digital Timer 9 Blower Speed Indicator Power Off Delay Digital Timer 69 amp Light Power Indicator Power Off Delay Timer Indicator a0 NOTE This range hood is designed to remove smoke cooking vapors and odors from the cook top area For best results start the range hood before cooking and allow it to operate several minutes after the cooking is completed to clear all smoke and odors from the kitchen Button functions 1 To power ON OFF the range hood and to activate power off delay timer 2 To decrease blower motor speed decrease timer value and enter timer mode 7 To increase blower motor speed increase timer value and cumulative timer reset 3 Lights up when blower motor is running 4 Shows current blower motor speed 1 6 5 Lights up when lights turned on 6 To turn
17. st be done by qualified professionals and in accordance with all applicable codes and standards including fire rated construction DO NOT attempt to install this appliance yourself Injury could result from installing the unit due to lack of appropriate electrical and technical background Due to the size and weight of this range hood two people installation is recommended Range hood may have very sharp edges please wear protective gloves if it is necessary to remove any parts for installing cleaning or servicing Activating any switch ON before completing installation may cause ignition or an explosion WARNING To reduce the risk of fire electric shock or injury to persons R a ds ee 9 10 11 12 For general ventilating use only DO NOT use to exhaust hazardous or explosive materials and vapors Ducted fans MUST always be vented to the outdoors Use only metal ductwork Old duct work should be cleaned or replaced if necessary to avoid the possibility of a grease fire Check all joints on duct work to insure proper connection and all joints should be properly taped The combustion air flow needed for safe operation of fuel burning equipment may be affected by this unit s operation Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society of Heating Refrigeration and Air Conditioning Engineers ASHRAE and
18. tion PART LIST one ee a a oa o1 memgwake pieco wa 1 na we recent ance 1 3 m 30 1 baffle filter PIPPES a Assembled omm mI ro Lo late ao y ww ram pls a a a O ee ne rome Fee Aurrursppe so sm 4 8 m www XtremeAirUsa com Page 5 OVERALL DIMENSIONS z NI M WM M MI 15 557 30 83 TN Ki 12 88 30 36 Model PX01 Model PX02 NS 18 89 32 68 si opes e e a ptt _ D aa mn mmt A a n A l e go ll a p ga E y s EN ae CA NG m mm i 2 Ma g e r AC Y o M us MT A fe b m nh 3 il Model PX04 amp PX04 I Model PX03 www XtremeAirUsa com Page 6 TOOLS NEED FOR INSTALLATION 1 Maker or pencil 2 Level 3 Measuring tape 4 Powered screwdriver or drill 5 Hlat amp Phillips screwdrivers 6 Utility knife VENTING METHODS Horizontal wall venting Option I Option 2 LIU side wall cap www XtremeAirUsa com Vertical roof venting Roof cap E l E m NT m i P E i Lo um i m aij I Em y au LI x i re a IIl LI I i Page 7 HEIGHT CLEARANCE 110 Min 28 C Max 33 86 hase VENTING REQUIREMENT IMPORTANT HB EEE AAA Aa A A AO ek SpA De Pe E A A E PB O E A O A A Da L L L L L L L Ls ERE WS Ge ese a a EXE ale E A ie Bes Pa Fm es E A A E ee REE NEVER e
19. ts duvica Touching y ebrobrecnl connections OF biir ex posed elec install this range hood Spinal or other bodi protective gloves if it is necessary to remove vere injury Stay clear of trical circultry Inside this range hood when Eh y are energized Gould roiu m dadih 3a a ee op ou os j h ly injuries could occur if it is not followed any parts for installing cleaning or servicing fan when motor is running rious bodily injury or property damage Note Type A anchors are designed for dry wall Not to be used with anv other types of walls Qty 6 PCS INSTALLATION OVERVIEW NOTE Use threaded drywall anchors only when mounting the hood on sheet rock Mounting the hood on wall studs or lumbers is highly recommended CAUTION Make certain the range hood is secure before releasing 1 Put a thick protective covering over counter top cook top or range to protect from damage or dirt Remove any hazardous objects around the area when installing 2 Disconnect main electrical supply prepare and run electrical wiring through ceiling or wall Leave approximately 12 of electrical cord hanging from the ceiling Do not restore power until wiring 1s completed 10 3 Use the below diagram to calculate the height of 2 mounting screws Make sure the hood is center of cook top Screw these 2 mounting screws on the wall leaving 1 8 space away from the wall Note Due to the weight and size of this unit please
20. ut the stainless luster and grain Always scrub lightly with clean cotton cloth and with the grain e DO NOT allow deposits to accumulate or remain on the hood e DO NOT use ordinary steel wool or steel brushes Small bits of steel may adhere to the surface and cause rusting e DO NOT allow salt solutions disinfectants bleaches or cleaning compounds to remain in contact with stainless steel for extended periods Many of these compounds contain chemicals which may be harmful Rinse with water after exposure and wipe dry with a clean cloth Cleaning Aluminum Grease Filter Stainless Steel Filter less Grill IMPORTANT Drain oil from oil containers before oil and residue overflow e The metal filters fitted by the factory are intended to filter out residue and grease from cooking It need not be replaced on a regular basis but are required to be kept clean e Filters should be cleaned after every 30 hours of use e Remove and clean by hand or dishwasher Spray Formula 4099 or equivalent degreasing detergent and leave to soak 1f heavily soiled Dry filters and re install before using hood Replacing Filters e Should filters wear out due to age and prolonged use please contact your local reseller for replacement filters Note Also replace damaged filter that has punctured or broken mesh bent or broken frame Replacing the light bulb e This range hood uses LED 2w bulb please refer to the actual specification of the hood purchased
21. xhaust air or terminate duct work into spaces between walls crawl spaces ceiling attics or garages All exhaust must be ducted to the outside Hood mounted too low could result in heat damage and fire hazard while hoods mounted too high will be hard to reach and will loose its performance and efficiency Use metal aluminum duct work only A minimum of 6 round standard for this range hood or 3 1 4 x 10 rectangular duct purchased separately adaptor not supplied must be used to maintain maximum airflow efficiency DO NOT use plastic vent DO NOT use 4 10 2 cm laundry type wall caps Fasten all connections with sheet metal screws and tape all joints with certified Silver Tape or Duct Tape Use caulking to seal exterior wall or roof opening around the cap Vent system must terminate to the outside roof or side wall For the most efficient amp quiet operation A distance of 28 to 33 1s recommended between stove top and the bottom of range hood It is recommended that the range hood be vented vertically through the roof through 6 or bigger vent work ALWAYS when possible reduce the number or transitions and turns If long duct run is required increase duct size from 6 to 7 or 8 If a reducer 1s used install a long reducer instead of a pancake reducer Reducing duct size will restrict airflow and decrease airflow thus reduce duct size as far away from opening as possible If turns or transitions are requir
22. y will at no charge replace at the Company s option only any parts or complete unit found to be defective The replacement parts or new unit will be covered by limited warranty for the balance of the two years period from the date of the original purchase Further the warranty for the motor extends for an additional 8 years total of three 10 years This warranty is not transferable This warranty does not apply to light bulbs ducts roof caps other accessories for ducting defects resulting from damages sustained during shipping unauthorized repair neglect misuse incorrect installation failure to follow instructions for care and maintenance for the product attempts to alter of modify the function of part or the complete assembly acts of God or any other circumstances beyond the control of The Company The warranty does not include normal maintenance and service The Warranty does not cover the costs of removal installation In the event of a products replacement or return the unit must be returned transportation prepaid The repaired or new model will be returned at the company expense The warranty on your XtremeAir hood begins on the date of original purchase Please complete the Product Registration Card and return it with the dated bill of sale or other evidence of the original proof of purchase within 30 days from purchase of the product to address shown in contact us Or register at www XtremeA1rUsa com Warranty For war
Download Pdf Manuals