Home
Product Introduction
Contents
1. PRODUCT MANUAL 6 ICP 250 UV Ionic Plasma Air Purifier A product of Purifion Canada introduction Congratulations on the purchase of your Purifion ICP 250 UV Ionic Plasma Air Purifier With proper care and attention you can enjoy many years of safe and economic service from this unit with many benefits to you and your family s health This Product Manual explains the features of the unit and its operation including safety precautions and how you can obtain service if required Table of Contents Safety precautions eWarranty eService ePlacement and controls Operation guide eSpecifications Safety Precautions Werning CAREFULLY READ THE FOLLOWING FAILURE TO OBSERVE ANY OF THESE WARNINGS COULD RESULT IN IRREVERSIBLE DAMAGE TO THE UNIT or ELECTRICAL SHOCK causing SERIOUS INJURY or even DEATH Do NOT attempt to repair the unit If repairs are required send it to an authorized dealer or a qualified electronics service technician Do NOT keep the unit where it is not stable and can be knocked over easily We recommend you keep it on a level floor surface Avoid inclined areas Do not store in areas with excessive moisture such as bathrooms Do NOT stare at the UV light or control buttons Despite the presence of a metal protective light shield do NOT place your face or body directly in front of the light Do NOT place objects inside the grill covers at any time while the Unit is
2. plates also known as the Dust Collection Blades or Filter NOTE There are three 3 fixed stainless steel plates combined into one single piece On occasion the unit will produce a faint buzzing noise This means the plates require cleaning Cleaning and re installation of the plates as shown here will stop any previous noises heard during operation Also in order to remove dust that accumulates on the wires inside you periodically turn the unit upside down do not shake the unit TO REMOVE THE PLATES First unplug the power cord Cusp your fingers under the opening marked Filter on top Gently slide the plates upward out of the unit housing Then remove any dust or other contaminants on the plates with a slightly damp cloth IMPORTANT DO NOT wash plates under a water tap in a bucket of water or with a water hose This can damage the internal components of the unit when the plates are placed back inside Only wash with slightly damp cloth Once clean slide the plates gently back Into the unit housing Plug the unit back in You should hear a single beep to confirm the plates are in place and the unit can be re started UV Lamp Replacement TO TAKE OFF REAR GRILL COVER First unplug the unit power cord Near the bottom of the rear grill cover side with handle at top you will see a plastic tab as shown in diagram Gently release the tab out and then gently push the grill cover down away from the housing TO REMOVE
3. plugged in This can result in electrical shock causing serious injury or even death Do NOT use the unit in industrial environments or warehouses For indoor use only Warranty Product Purif Ion Ionic UV Plasma Air Purifier ICP 250 Warranty Period Three 3 year Limited Warranty on parts and labour as described below Warranty Exclusions Packaging Unit Box carrying case User Manual and UV Lamp Additional exclusions are described below Purifion Canada gives the following warranty to the purchaser of the above described product if sold or distributed in Canada only by Purifion Canada or by an authorized dealer of Purifion Canada Purifion Canada warrants that the product is free under normal use and maintenance from any defects in materials or workmanship If any defects are found after receipt of a warranty claim from the purchaser Purifion Canada will at its own discretion repair or replace the product specified above Excluded from the warranty are the following a Any defects or repairs caused by negligent use abusive operation accident liquid spillage on the unit improper installation or inappropriate use as defined in the users manual b Ifthe described product has been tampered with or modified adjusted or repaired by anyone other than Purifion Canada c Damage caused to the product by the use of cleaning products or cleaning solutions not prescribed in the user s manual d Any replacement
4. EGISTRATION CARD Model Number Purifion ICP 250 Ionic UV Plasma Air Purifier Serial Number under the base of unit Colour Scheme Platinum Burl Oak Date of Purchase Retailers Name f app Retailers Location fapp Street number name and city Customer Name s Address City Province Postal Code Email Telephone Fax Purchase Date Purchased from Web Shopping Cart Telephone Retail Store Other KEEP THIS WARRANTY CARD SHOULD YOU REQUIRE WARRANTY SERVICE PLEASE FILL OUT THE ABOVE INFORMATION AND SUBMIT IT ALONG WITH THE PRODUCT TO PURIFION CANADA AT THE ADDRESS SHOWN ON THE BOX CONDITIONS OF THREE YEAR LIMITED WARRANTY ENCLOSED Placement Controls Unit Placement The unit occupies little space and can be used in many places like the office dining room bedroom etc Place the unit on a level surface with at least 30 cm clearance from any wall draperies or furniture Controls All control buttons are located at the top of the unit The blue LED lights make it possible to see the controls at night The power controls consist of Power Speed Turbo and UV buttons Operation Indicator Lights The indicator lights let you know the status of the unit Power LED This Triangular shaped LED tells you if the unit is on or off Break LED Turns on in case of a problem with the internal high voltage wires Short LED Turns on in case of an electric problem wit
5. and INSTALL THE UV TUBE Twist the burnt out tube 90 and pull out from bottom terminal marked lamp BASE on the diagram To install the tube do the reverse Place the tube into the terminals and twist 90 to lock it in TO PUT BACK REAR GRILL COVER As shown in the diagram line up the arrow on the rear cover with the bottom arrow marked on both sides of the unit housing Then slide the rear cover upward until the arrow on the rear cover is lined up with the top arrow on the housing At the same time be sure to hold the top of the rear cover with your other hand and push it up clicking the rear cover back into the unit housing LAMP LIFETIME The high efficiency UV lamp will run for about 8 000 hours on average between replacements or about one year of continuous operation REPLACEMENT UV LAMPS Use only UVC 15W lamp bulbs which may be purchased from Purifion Canada or from any authorized dealer Specifications Product lonic UV Plasma Air Purifier Description Model No ICP 250 Voltage 120VAC 60 Hz Power 28 watts maximum Consumption Air Purification UV Sterilization De odourization Ultraviolet Light UVC 15W Tube Length of Power Cord Product Weight Product Size 228x170x795 mm All Rights Reserved 2004 PURIFION CANADA 181 2150 Burnhamthorpe Rd West Mississauga ON L5L 3A2 TEL 905 593 9268 Greater Toronto Area TOLL FREE 1 866 806 9833
6. h the internal circuitry Clean LED Turns on to indicate that it is time to clean the collection plates Simultaneously an audible beep will go off to alert you that cleaning is required Slide out the plates from the unit and wipe off with a damp cloth After cleaning just install blades in their original position NOTE If the unit is making a buzzing noise you can clean the plates even before the Clean LED is activated Failure to follow these instructions could result in damage to the unit Removal Storage The unit box is also a convenient carrying case for those who might want to transport the unit safely to another location For future use safely store the box and the associated packaging Power Connection Unwrap the cord which is coiled underneath the base of the unit and plug it into the correct power outlet Power ON To activate power to the unit press the Power button 1 Power Level Settings Press the speed button 2 to select the units power level Choose from Low I Medium Il or High III Press the Turbo button 3 for five minutes on the highest power level Your previous power level will resume once the five minutes Turbo function has elapsed UV Lamp Activation Press the UV Lamp button 4 in order to turn on the Ultraviolet lamp STEP 1 i STEP 2 Cleaning Stainless Steel Plates If the audible beep goes off and the LED indicator is flashing it is time to clean the
7. of changeable parts applicable only to the UVC 15W lamp a Any cosmetic damage caused to the surface or exterior of the unit by normal wear and tear b Any damage caused by interfering electrical devices and or high voltage transmission lines or lightning strikes Should the ICP 250 fail to operate during the warranty period warranty service maybe obtained by taking the ICP 250 this limited warranty and proof of purchase to the authorized dealer where the product was purchased or by sending it to PURIFION CANADA 181 2150 BURNHAMTHORPE RD WEST MISSISSAUGA ON L5L 3A2 TEL 905 593 9268 TOLL FREE 1 866 806 9833 The warranty cannot be extended or modified by any authorized dealer of Purifion Canada The Purchaser is responsible for any cost of removal reinstallation transportation or insurance costs incurred with respect to a warranty claim Corrections of defects or replacement of the unit at the expiration of the warranty period constitute completion of the obligations of Purifion Canada or the authorized dealer to the purchaser with respect to the product THIS WARRANTY IS VALID THREE 3 YEARS FROM PURCHASE DATE PLEASE DO NOT FORGET TO FILL IN THE WARRANTY CARD AND RETURN IT TO PURIFION CANADA IF MAKING A WARRANTY CLAIM For any questions or clarifications that you might have regarding the product warranty or any other issues contact us by mail or phone or at or visit our web site at Warranty Card WARRANTY R