Home
User Manual
Contents
1. a serious operating problem stop using the unit immediately Never try to repair the unit by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized technical assistance center Always use the same type spare parts Do not touch any power cables during operation as the high voltage may cause an electric shock Warning To prevent or reduce the risk of electrical shock or fire do not expose the unit to rain or moisture Do not open the unit within five minutes after switching off The housing and lenses must be replaced if they are visibly damaged Installation The unit should be mounted via its screw holes onto the bracket Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating Make sure that the structure to which you are attaching the unit to is secure and is able to support a weight of 10 times of the unit s weight Always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture The equipment must be installed by professionals and it must be installed in a place where is out of the reach of people and no one can pass by or under it 2 Features amp Technical Specifications Control Sound active auto Master slave and DMX 512 modes DMX Channels 1 and 8 Electronic dimming 0 100 Electronic strobe with pulse and random effects High output with low power consumption Compact s
2. Equinox Triclops Beam Order code EQLED49 User Manual Contents 1 Safety Instructions Features amp Specifications How To Set The Unit How To Control The Unit Troubleshooting Fixture Cleaning 1 Safety Instruction WARNING A Please read the instructions carefully as they include important information about installation usage and maintenance Please keep this User Guide for future consultation If you sell the unit to another user be sure that they also receive this Unpack and check carefully that there is no transportation damage before using the unit Before operating ensure that the voltage and frequency of the power supply match the power requirements of the unit It s important to ground the yellow green conductor to earth in order to avoid electric shock The unit is for indoor use only Use only in a dry location The unit must be installed in a location with adequate ventilation at least 50cm from adjacent surfaces Be sure that no ventilation slots are blocked Disconnect the mains power before replacement or servicing Make sure there are no flammable materials close to the unit while operating as they may cause a fire hazard Always use a Safety cable when installing this unit Do not carry the unit by its head only always carry it using the base The maximum ambient temperature is to 40 degrees C Don t operate it where the temperature is higher than this In the event of
3. Press the MODE button to select dcr Press the ENTER button and the display will blink Use the DOWN and UP buttons to choose the address from 1 512 Once the address has been selected press the ENTER button to confirm To go back to the functions without any changes press the MENU button again Press and hold the MENU button for one second or wait for one minute to go back to the main ml E LI M Slave Mode Press the MENU button to select 21110 Press the ENTER button and the display will blink Use the DOWN and UP buttons to select the normal or 2 light show or nASE for master mode Once the mode has been selected press the ENTER button to confirm To go back to the functions without any changes press the MENU button again Press and hold the MENU button for one second or wait for one minute to go back to the main menu x Po ttlt Show Mode Press the MENU button to select 24 ic Press the ENTER button and the display will blink Use the DOWN and UP buttons to select the show mode between Stal 0 and Stn 8 Once the mode has been selected press the ENTER button to confirm To go back to the functions without any changes press the MENU button again Press and hold the MENU button for one second or wait for one minute to go back to the main menu J E 7 i Sound Mode Press the MENU button to select SUUnI Press the ENTER button and the display will blink Use the DOWN and UP buttons to sel
4. ad Y position E 000 008 009 255 The second head LED colour selection 000 255 The third head Y position Aaa 000 008 009 255 The third head LED colour selection 097 104 5 Troubleshooting Following are a few common problems that may occur during operation and some suggestions for easy troubleshooting A The unit does not work no light and the fan does not work 1 Check the connection of the power and the main fuse B Not responding to DMX controller 1 If the DMX address is showing but no response to the controller check the address settings and DMX polarity 2 Try another DMX controller C No response to the sound 1 Make sure the unit is not receiving a DMX signal 2 Check the microphone to see if it is good by tapping it The microphone is located on the bottom plate of the unit 6 Fixture Cleaning The cleaning of external optical lenses must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause a greater accumulation of dirt on the unit s optics Clean with a soft cloth using normal glass cleaning fluid or mild soapy water e Always dry the parts carefully e Clean the external optics at least every 20 days www prolight co uk
5. ad Y position transmission problems and interference Itis always advisable to connect a DMX terminal 000 008 129 136 R G B Resistance 120 ohm 1 4W between pin2 DMX and function pin3 DMX of the last fixture 009 016 R 137 144 017 024 m 145 152 1 In the last unit the DMX has to be terminated with a termination plug Solder 025 032 B 153 160 a 120 ohm 1 4W resistor between pin 2 DMX and pin 3 DMX into a 3 pin 033 040 O wo 161 168 XLR plug and plug it in the DMX output of the last unit CH4 041 048 O A 169 176 2 Connect the units together in a daisy chain with an XLR plug from the output The first 049 056 RG 177 184 of the unit to the input of the next unit The cable can not be branched or split eaiouir 065 072 RW 193 200 3 The DMX output and input connectors are a pass through type to maintain the No G W A R G R B R W SA o selection 073 080 R A 501 208 DMX AL meh one of the units power is pier nN EEee 4 Each lighting unit needs to have an address setup to receive the data sent by 081 088 G B 209 216 R G B W l the controller The address number is between 0 512 089 096 G W 217 224 R G W A Sil ene ee EA 5 The end of the DMX 512 system should be terminated to reduce signal errors 105 112 B W 233 240 R B W A l a 6 3 pin XLR cable wiring configuration De a Sana TA OTOFA 3 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal 121 128 249 255 R B A W A 000 255 The second he
6. ect the on sound on or otf sound off mode Once the mode has been selected press the ENTER button to confirm To go back to the functions without any changes press the MENU button again Press and hold the MENU button for one second or wait for one minute to go back to the main menu CoO_C JC Ft J Sound sensitivity Press the MENU button to select 5fn5 Press the ENTER button and use the DOWN and UP buttons to select the sound sensitivity 0 100 _ Led Display Press the MENU button to select LEd Press the ENTER button and the display will blink Use the DOWN and UP buttons to select the aa Led display on or orr Led display off mode Once the mode has been selected press the ENTER button to confirm To go back to the functions without any changes press the MENU button again Press and hold the MENU button for one second or wait for one minute to go back to the main menu Display Inversion Press the MENU button to select Id Sf press the ENTER button to change to the mode display normal It will be automatically saved after 8 seconds Press the ENTER button again to select the mode dS iA display inversion To go back to the functions press the MENU button Press and hold the MENU button for one second or wait for one minute to go back to the main menu Display normal mode is for floor standing the unit Display inversion mode is for hanging the unit from a ce
7. iling C Ltt Auto Test Press the MENU button to select t St Press the ENTER button and the unit will run a self test with its built in programs To go back to the functions without any changes press the MENU button again Press and hold the MENU button for one second or wait for one minute to go back to the main menu I Itt Reset Press the MENU button to select 52t Press the ENTER button and all channels of the unit will return to their standard position 4 How To Control The Unit 1 Master slave built in preprogram function 2 Universal DMX controller There is no need to turn the unit off when you change the DMX address as new DMX address setting will be affected at once Every time you turn the unit on it will show i L EL g on the display and move all the motors to their home position and you may hear some noises for about 20 seconds After that the unit will be ready to receive DMX signal or run the built in programs 4 1 Master Slave Built In Preprogrammed Function By linking the units in master slave connection the first unit will control the other units to give an automatic sound activated synchronized light show This function is good when you want an instant show You have to set the first unit as master and select show 0 8 from the Show Mode The other units must be set to either Slave 1 normal or Slave 2 2 light show mode A DMX cable between the units for daisy chaining is needed 2 light sho
8. ize and low weight Voltage 100V 240V 50 60Hz Fuse T3A 250V Power consumption 85W Light source 15 x 3W RGBWA LED Dimensions 345 x 385 x 235mm Weight 3 9kg Power sockets IEC in out XLR sockets 3 pin XLR in out 3 How To Set The Unit 3 1 Control panel OOOO MONU DO WH UP OTER POWER IN 100 240V 50 60Hz FUSE F3A a DMX IH DEKOLT 2 O o 2 Display Shows the various menus and selected functions Button MENU Selects the programming functions DOWN To go backward in the selected functions To go forward in the selected functions ENTER Confirms the selected functions Mains input Connection to the power supply DMX input output For DMX 512 linking Use 3 pin XLR cables to link to the controller or to other units To select any of the given functions press the MODE button up to where the required function is showing on the display Select the function by pressing the ENTER button and the display will blink Use the DOWN and UP buttons to change the mode Once the required mode has been selected press the ENTER button to confirm To go back to the functions without any changes press the MENU button again Press and hold the MENU button for one second or wait for one minute to go back to the main menu The main functions are as below ADDR 001 512 SOUN ON OFF SENS 0 100 TEST HOURS VER REST yo PU DMX Address Setting
9. w In slave mode Slave 1 means the unit works normally and Slave 2 means 2 light Show In order to create a great light show you can set Slave 2 on the second unit to get contrast movement to each other even if you have two units only 4 2 DMX Controller By using a universal DMX controller to control the units you will need to set a DMX address from 1 to 512 so that the units can receive a DMX signal Press the MENU button until ccc is showing on the display Press the ENTER button and the display will blink Use the DOWN and UP buttons to change the DMX 512 address Once the address has been selected press the ENTER button to confirm To go back to the functions without any changes press the MENU button again Press and hold the MENU button one second or wait for one minute to go back to the main menu Please refer to the below diagram to address your first 4 units Channel Unit 1 Unit 2 Unit 3 Unit 4 mode Address Address Address Address Poa 9o r B 8 channels 4 3 DMX 512 Configuration 1 channel DMX chart Channel Value Function 000 007 Blackout 008 037 038 067 068 097 CH1 098 127 Sound activated 8 channel DMX chart 4 4 DMX512 CONNECTION Channel Value Function COMMON 000 255 Full dimmer 0 100 DMX Ci DMX INPUT DMX OUTPUT 000 008 DMX 009 255 Strobe slow to fast Termination reduces signal errors and to avoid signal CH3 iti CH3 O 000 255 The first he
Download Pdf Manuals
Related Search
Related Contents
5INGER* - Singer Nokia BH-218 disponible ici TELEFUNKEN TFD19200V12 PM2600 - Dynacord Wayne 450002-001 User's Manual WR 110 - Tecnica Industriale S.r.l. Prezados (as) Senhores (as): Visando eventual Copyright © All rights reserved.
Failed to retrieve file