1. 2 2 Electrical Specifications 23x 5 C PT 100 ohm Resolution Range Accuracy 0 1 C 199 9 to 850 0 0 4 1 C 0 1 F 327 0 to 999 9 F 0 4 9o 1 8 F 1000 to 1562 F 0 4 2F Pt 100 ohm probe 101 is the optional accessory Type K J T E R S Sensor Resolutio Range Accuracy TypeK 00 1 50 1 10 100 0 0496 1C 50 0 to 999 9 C 0 4 0 5 1 C 1000 to 1300 C 04 1 0 2412 58 110 148 0 0 496 1 8 F 58 0 to 999 9 F 0 4 96 1 F 1000 to 2372 F 04 2F 0 1C 50 1 to 100 0 C 0 4 96 1 C 50 0 to 999 9 0 4 96 0 5 1 1000 to 1150 0 496 1C 0 1 F 58 1 to 148 0 F 0 4 96 1 8 F 58 0 to 999 9 F 0 4 96 1 F 1 F 1000 to 2102 F 0 4 2 F T Type T 0 1 C 50 1 to 100 0 0 4 1 C 50 0 to 400 0 C 0 4 96 0 5 0 1 F 58 1 to 148 0 F 0 4 96 1 8 F 58 0 to 752 0 F 0 4 96 1 F Type E 10 1 50 1 to 100 0 0 4 1 C I 1 50 0 to 900 0 0 4 96 0 5 0 1 F 58 1 to 148 0 F 04 1 8 58 0 to 999 9 F 0 4 96 1 F 1 1000 to 1652 F 0 496 2 F 1 0106000 0 5 1 601 to 1700 0
2. 4 channels T1 T2 T3 T4 T1 T2 Microcomputer circuit provides intelligent function and high accuracy Offset adjustment for the Type K J T E R S measurement Offset adjustment for the Pt 100 measurement Measuring unit can select to C or F Real time SD memory card Datalogger it Built in Clock and Calendar real time data recorder sampling time set from 1 second to 3600 seconds Manual datalogger is available set the sampling time to O second during execute the manual datalogger function it can set the different position location No position 1 to position 99 Innovation and easy operation computer is not need to setup extra software after execute datalogger just take away the SD card from the meter and plug in the SD card into the computer it can down load the all the measured value with the time information year month date hour minute second to the Excel directly then user can make the further data or graphic analysis by themselves SD card capacity 1 GB to 16 GB LCD with green light backlight easy reading Can default auto power off or manual power off Data hold record max and min reading Microcomputer circuit high accuracy Power by UM3 AA 1 5 V x 6 batteries or DC 9V adapter RS232 USB PC COMPUTER interface Heavy duty amp compact housing case 2 Specifications 2 1 General Specifications Circuit Custom one chip of microprocessor LSI c
3. 1 Use the Button 3 5 Fig 1 or V Button 3 6 Fig 1 to adjust the value 0 1 2 5 10 30 60 120 300 600 1800 3600 seconds Remark If select the sampling time to 0 second it is ready for manual Datalogger 2 After the Sampling value is selected press the Enter Button 3 4 Fig 1 will save the setting function with default 7 7 SD memory card Format When the lower display show Sd F 1 Use the A Button 3 5 Fig 1 or V Button 3 6 Fig 1 to select the upper value to VES yES Intend to format the SD memory card no Not execute the SD memory card format 2 If select the upper to yES press the Enter Button 3 4 Fig 1 once again the Display will show text yES Ent to confirm again if make sure to do the SD memory card format then press Enter Button once will format the SD memory clear all the existing data that already saving into the SD card 8 Power Supply from DC Adapter The meter also can supply the power supply from the DC 9V Power Adapter optional Insert the plug of Power Adapter into DC 9V Power Adapter Input Socket 3 13 Fig 1 The meter will permanent power ON when use the DC ADAPTER power supply The power Button function is disable 9 Battery Replacement 1 When the left corner of LCD display show d XJ it is necessary to replace the battery However in spec measurement may still be made for several hours aft
4. lbi Mear Hb Y Cama ors TLE et Le ee Fun aL IL Ti Gee ite LM AERE UITA I d Fia Rar um d na Lb ae MAn TLA See ELF iL LM d fed EJ isegi m FLA ar ELP Grha I h Sr rr E 4 n ij 1 HED tee info tursdaletechnicalservices co uk Table of contents 3 2 2 5 m 3 Ze CIeneral SD CITICOU OBS 3 T 6 3 Front Fame ICSC MIDI 7 d PEOCEGUES 25 9 a uM k measure mmt 9 Be Dype ds ODER 9 9 sot A E AEE et enue _ 8 BaD NAVA HO e R E OO 9 4p Data Record Maxs Min STI 9 BaCk DECON OE e a 9 25 DO ioe A T EE 9 5 1 Preparation before execute datalogger function 9 5 2 Auto Datalogger Set sampling time 1 second 10 5 3 Manual Datalogger Set sampling time 0 2222200 10 0 0
5. 10 Decl Bie OM 11 5 5 Check sampling time information 11 930 SED Edid DOtaStruc 11 6 Saving data from the SD card to the computer EXCEL 40000 1 EXCEL Gata Screen 12 LEE 12 7 1 Set clock time Year Month Date Hour Minute 13 1 2 Decimal ponto o D 13 T Auto DO Wer OFF MANAG ost MERO 13 p pet beeper sond 13 Tomp umil erse 14 Ime SCCONdS ee ____6__ ___ 14 FEES D a no Cal E 14 G Powersupply tom DC _____ _____ _ ____ 14 2 Bane Replace RIED 14 2 _84 15 IT oOLHCSet AUT SUM BL 16 11 1 Type KI offset adjustment 16 t2 POO chin OF SEE ad E 16 12 Op onal Type re N 17 ER 18 PCE info tursdaletechnicalservices co uk 1 Features Type K J T E R S Pt 100 ohm measurement with 4 display Show 4 channels display on the LCD at the same time 100 to 1300 Type J 100 to 1200 Pt 100 ohm 199 9 to 850 0 C F 0 1 degree 1 degree
6. press the Enter Button 3 4 Fig 1 will save the setting function with default 7 3 Auto power OFF management When the lower display show PoFF 1 Use the A Button 3 5 Fig 1 or V Button 3 6 Fig 1 to select the upper value to YES or yES Auto Power Off management will enable no Auto Power Off management will disable 3 After select the upper text to yES or press the Enter Button 3 4 Fig 1 will save the setting function with default 7 4 Set beeper sound ON OFF When the lower display show bEEP 1 Use A Button 3 5 Fig 1 or V Button 3 6 Fig 1 to select the upper value to YES or yES Meter s beep sound will be ON with default no Meter s beep sound will be OFF with default is power ON 3 After select the upper text to yES or no press the Enter Button 3 4 Fig 1 will save the setting function with default 13 info tursdaletechnicalservices co uk 7 5 Select the Temp unit to C or F When the lower display show t CF 1 Use the A Button 3 5 Fig 1 or V Button 3 6 Fig 1 to select the upper Display text to C or F C Temperature unit is C F Temperature unit is F 2 After Display unit is selected to C or F press the Enter Button 3 4 Fig 1 will save the setting function with default 7 6 Set sampling time Seconds When the lower display show SP t
7. 22 21 2009 6 19 11 02 30 32 3 K Temp 27 9 T2 KTemp 27 9 T3 KTemp 27 9 KTemp C 23 22 2009 6 19 11 02 31 32 3 Tl KTemp 30 1 T2 KTemp 279 T3 KTemp 279 T4 KTemp C 24 23 2009 6 19 11 02 32 30 8 KTemp 30 1 T2 KTemp 29 2 T3 K Temp 27 9 KTemp C EXCEL graphic screen for example Lissat 1224 TA Lisat 40 35 25 vE T1 12 TS 15 14 10 5 0 A ob Sh 9 go se a9 Gv oo d O ah o a a a a mv oF OM M Pos Po o o s vay om SY Sue CES dos Aes NY C 7 Advanced Setting Under do not execute the Datalogger function press the SET Button 3 7 Fig 1 continuously at least two seconds will enter the Advanced Setting mode then press the Next Button 3 3 Fig 1 once a while in sequence to select the seven main function the lower display will show Set clock time Year Month Date Hour Minute Second dEC Set SD card Decimal character PoFF Auto power OFF management bEEP Set beeper sound ON OFF t CF Select the Temp unit to C or F SP t Set sampling time Hour Minute Second Sd F SD memory card Format Remark During execute the Advanced Setting function if press ESC Button 3 2 Fig 1 once will exit the Advanced Setting function the LCD will return to normal screen 12 info tursdaletechnicalservices co uk
8. 7 1 Set clock time Year Month Date Hour Minute Second When the lower display show dAtE 1 Press the Enter Button 3 4 Fig 1 once Use the A Button 3 5 Fig 1 or V Button 3 6 Fig 1 to adjust the value Setting start from Year value After the desired value is set press the Enter Button 3 4 Fig 1 once will going to next value adjustment for example first setting value is Year then next to adjust Month Date Hour Minute Second value 2 After set all the time value Year Month Date Hour Minute Second the screen will jump to SD card Decimal character setting screen Chapter 7 2 Remark After the time value is setting the internal clock will run precisely even Power is off The battery is under normal condition no low battery condition 7 2 Decimal point of SD card setting The numerical data structure of SD card is default used the as the decimal for example 20 6 1000 53 But in certain countries Europe is used the as the decimal point for example 20 6 1000 53 Under such situation it should change the Decimal character at first When the lower display show dEC 1 Use the A Button 3 5 Fig 1 or V Button 3 6 Fig 1 to select the upper value to Euro Use as the Decimal point with default Euro Use the Decimal point with default 2 After select the upper text to Euro
9. Fig 1 once the display will show example as following If intend to make the offset adjustment for Pt 2 it should insert the probe to PT2 input socket Pressing R button 3 6 Fig 1 once the display will show example as following 16 PCE info tursdaletechnicalservices co uk If not insert probe to PT1 PT2 input measuring adjust socket it will show value value Em Use the A button 3 5 Fig 1 W button 3 6 Fig 1 to adjust the desiring value on right bottom display Pressing Enter button 3 4 Fig 1 once the adjustment value will save into memory then return to normal measuring screen and finish the offset adjustment procedures The above offset adjustment for Pt 100 ohm is valid for PT1 PT2 individually 12 Optional Type K Temp probe Type K TP 01 Max short tern operating Temperature 300 C 572 F t is an ultra fast response naked bead thermocouple suitable for many general purpose application Thermocouple Measure Range 50 C to 900 C Probe 50 F to 1650 F TP 02A Dimension 10cm tube 3 2mm Dia Thermocouple Measure Range 50 to 1200 Probe 50 F to 2200 F 03 Dimension 10cm tube 8mm Dia Surface Probe Measure Range 50 to 400 Type K TP 04 50 F to 752 F Size Temp sensing head 15 mm Dia Probe length 120 mm 17 info tursdaletechn
10. input socket Pressing the T1 T2 button 3 6 Fig 1 display will show the difference temperature value between T1 T2 PT1 PT2 as info tursdaletechnicalservices co uk 1 2 T1 T2 value 4 5 Data Hold During the measurement press the Hold Button 3 3 Fig 1 once will hold the measured value amp the LCD will display a HOLD symbol Press the Hold Button once again will release the data hold function 4 6 Data Record Max Min reading 1 The data record function records the maximum and minimum readings Press the REC Button 3 4 Fig once to start the Data Record function and there will be a REC symbol on the display 2 With the REC symbol on the display a Press the REC Button 3 4 Fig 1 once the REC MAX symbol along with the maximum value will appear on the display If intend to delete the maximum value just press the Hold Button 3 3 Fig 1 once the display will show the REC symbol only amp execute the memory function continuously b Press the REC Button 3 4 Fig 1 again the REC MIN symbol along with the minimum value will appear on the display If intend to delete the minimum value just press the Hold Button 3 3 Fig 1 once the display will show the REC symbol only amp execute the memory function continuously C To exit the memory record function just press the REC button 2 seconds at least T
11. 27 6 Tl KTemp 27 7 T2 KTemp 27 7 T3 KTemp 277 T4 KTemp C 5 4 2009 60 19 11 02 13 27 6 Tl KTemp 27 7 T2 K Temp 277 KTemp 277 4 K Temp C 6 5 2009 6 19 11 02 14 27 6 Tl KTemp 27 7 T2 KTemp 27 7 T3 KTemp 27 7 KTemp 7 6 2009 6 19 11 02 15 27 7 Tl KTemp 27 7 T2 KTemp 27 7 T3 KTemp 27 7 KTemp C 8 7 2009 6 19 11 02 16 27 7 Tl KTemp 27 7 T2 KTemp 27 8 T3 KTemp 27 8 T4 KTemp C 9 8 2009 6 19 11 02 17 27 7 Tl KTemp 277 T2 KTemp 27 8 T3 KTemp 27 8 KTemp C 10 9 2009 6 19 11 02 18 27 7 T KTemp 27 8 T2 KTemp 27 8 T3 KTemp 27 8 KTemp C 11 10 2009 6 19 11 02 19 27 7 Tl KTemp 27 8 T2 KTemp 27 8 T3 K Temp 27 8 4 KTemp C 12 11 2009 60 19 11 02 20 27 7 Tl KTemp 27 8 T2 K Temp 27 8 K Temp 27 8 4 KTemp C 13 12 2009 65 19 11 02 21 27 7 Tl KTemp 27 8 T2 KTemp 27 8 T3 KTemp 278 T4 KTemp C 14 13 2009 6 19 11 02 22 27 7 KTemp 27 8 T2 KTemp 27 9 T3 KTemp 27 8 T4 KTemp C 15 14 2009 6 19 11 02 23 27 7 Tl KTemp 27 8 T2 KTemp 27 9 T3 KTemp 27 8 T4 KTemp C 16 15 2009 6 19 11 02 24 27 7 Tl KTemp 27 8 T2 KTemp 27 9 T3 KTemp 27 8 T4 KTemp C 1 16 2009 6 19 11 0225 27 7 Tl KTemp 27 8 T2 KTemp 27 9 T3 KTemp 27 8 T4 KTemp C 18 1 2009 6 19 11 02 26 27 7 Tl KTemp 27 8 T2 KTemp 27 9 T3 KTemp 27 8 KTemp 19 18 2009 6 19 11 02 27 27 7 Tl KTemp 27 9 T2 KTemp 27 9 T3 KTemp 27 9 KTemp 20 19 2009 6 19 11 02 28 27 8 Tl KTemp 279 T2 KTemp 279 T3 KTemp 279 T4 KTemp C 2l 20 2009 6 19 11 02 29 29 3 KTemp 27 9 T2 KTemp 279 T3 KTemp 27 9 KTemp C
12. 5 1 1 F 32 to 1112F 0 596 29F 1113 to 3092 0 596 2 F 1 0 to 600 0 5 1 C 601 to 1500 0 5 1 C 1 F 32 to 1112 0 5 2 1113 to 2732 0 5 2 Remark a Accuracy value is specified for the meter only b Accuracy is tested under the meter s environment temperature within 23 5 c Linearity Correction Memorize the thermocouple s curve into the intelligent CPU Above specification tests under the environment RF Field Strength less than 3 V M amp frequency less than 30 MHz only 3 Front Panel Description 3 1 Display 3 2 Power Button ESC Backlight Button 3 3 Hold Button Next Button 3 4 REC Button Enter Button 3 5 Type Button A Button L Button 3 6 T1 T2 Button Button Button 3 SET Button Time check Button 3 8 Logger Button OFFSET Button Sampling time check Button 3 9 T1 T2 T3 T4 input socket Type J 3 10 PT1 input socket Pt 100 ohm 3 11 PT2 input socket Pt 100 ohm 3 12 RS 232 output terminal 3 13 DC 9V adapter socket 3 14 Tripod Fix Nut 3 15 Battery Cover Screws info tursdaletechnicalservices co uk 3 16 Battery compartment Cover 3 17 Stand 3 18 SD card socket 4 Measuring Procedure 4 1 Type K measurement 1 Power on the meter by pressing the Power button 3 2 Fig 1 once After already power
13. WWW pce industrial needs com Tursdale Technical Services Ltd Unit N12B Tursdale Business Park Co Durham DH6 5PG United Kingdom Phone 44 0 191 377 3398 Fax 44 0 191 377 3357 info tursdaletechnicalservices co uk http www industrial needs com Manual Digital Thermometer PCE T 390 fa LE OE Gom l4 E um IL temp E ELF Li uL __ Tidi Fi aem OH ILE eC i am ia Ti Cmn ILE ee m ha Liri ibb ti _ Im Aum u _ 15 nd _ un TL ieee Bp HE Vi i M un __ 7 i ELI n LJ ur ILE Ti ite E um ILE T m i 14 bib m ILE 7 7 m HER Ln iia SL iama i am ai aea iia aa ama ELE Cee E ELE J __ m lee 4 rm Bim Fin ti rmt Mm 20 Ow Mit ILE t Hiti Pee m EN Oe ILE PLS eee mr mr iiia Ha Pepi ___ Li Dito Ii Ti ei HAP D ILS u mm iim fi oe i wl OE Sa EHI BSG ELA PS ee L Dereal ILE UD eS ppm p matry hi Ble
14. en 08 to D1 is 00001234 DO End Word 5232 FORMAT 9600 8 1 Baud rate 9600 Parity No parity Data bit no 8 Data bits Stop bit Stop bit PCE info tursdaletechnicalservices co uk 15 info tursdaletechnicalservices co uk 11 Offeset Adjustment 11 1 Type K J T E R S offset adjustment 1 Set the function to Type K or other type J E R T S 2 Insert the probe to the T1 input socket 3 9 Fig 1 3 Pressing Offset button 3 8 Fig 1 continuously at least two seconds then release the display will show f not insert probe to T1 input socket measuring adjust it will show Err value value Use the button 3 5 Fig 1 button 3 6 Fig 1 to adjust the desiring value on right bottom display Pressing Enter button 3 4 Fig 1 once the adjustment value will save into memory then return to normal measuring screen and finish the offset adjustment procedures The above offset adjustment for Type K J T E R S is valid for T1 T2 T3 T4 at the same time 11 2 Pt 100 ohm offset adjustment 1 Set the function to Pt 100 ohm 2 Insert the Pt 100 ohm probe to the PT1 PT2 input socket 3 Pressing Offset button 3 8 Fig 1 continuously at least two seconds then release the display will show 4 If intend to make the offset adjustment for Pt 1 it should insert the probe to PT1 input socket Pressing L button 3 5
15. er low battery indicator appears before the instrument become inaccurate 2 Loose the Battery Cover Screws 3 15 Fig 1 and take away the Battery Cover 3 16 Fig 1 from the instrument and remove the battery 14 3 Replace with DC 1 5 V battery UM3 Alkaline heavy duty x 6 PCs reinstate the Cover 4 Make sure the battery cover is secured after changing the battery 10 The instrument has RS232 PC serial interface via a 3 5 mm terminal 3 12 Fig 1 The data output is a 16 digit stream which can be utilized for user s specific application RS232 lead with the following connection will be required to link the instrument with the serial port RS232 PC Serial Interface Meter 9W D Connector Center 3 5 mm jack plug o Ground shield 2 2K resistor The 16 digits data stream will be displayed in the following format 015 014 D13 D12 D11 010 09 D8 D7 D D5 D4 D3 D2 D1 DO Each digit indicates the following status D15 Start Word D14 4 D13 When send the upper display data 1 When send the lower display data 2 D12 D11 Annunciator for Display C 01 F 02 010 Polarity 0 Positive 1 Negative D9 Decimal Point DP position from right to the left 0 1 1 DP 2 2 DP 3 3 DP 08 to 01 Display reading D1 LSD 08 MSD For example If the display reading is 1234 th
16. he display will revert to the current reading 4 7 LCD Backlight ON OFF After power ON the LCD Backlight will light automatically During the measurement press the Backlight Button 3 2 Fig 1 once will turn OFF the LCD Backlight Press the Backlight Button once again will turn ON the L CD Backlight again 5 Datalogger 5 1 Preparation before execute datalogger function a Insert the SD card Prepare a SD memory card 1 GB to 16 GB optional insert the SD card into the SD card socket 3 18 Fig 1 The front panel of the SD card should face against the down case b SD card Format If SD card just the first time use into the meter it recommend to make the SD card Format at first please refer chapter 7 7 page 19 info tursdaletechnicalservices co uk c Time setting If the meter is used at first time it should to adjust the clock time exactly please refer chapter 7 1 page 16 d Decimal format setting The numerical data structure of SD card is default used the as the decimal for example 20 6 1000 53 But in certain countries Europe is used the the decimal point for example 20 6 1000 53 Under such situation it should change the Decimal character at first details of setting the Decimal point refer to Chapter 7 2 page 17 5 2 Auto Datalogger Set sampling time 2 1 second a Start the datalogger Press the REC Button 3 4 Fig 1
17. icalservices co uk 13 Patent The meter SD card structure already get patent or patent pending in following countries Germany 20 2008 016 337 4 TAI WAN M 358970 M 359043 CHI NA ZL 2008 2 0189918 5 ZL 2008 2 0189917 0 USA Patent pending In this direction will find a vision of the measurement technique http www industrial needs com measuring instruments htm NOTE This instrument doesn t have ATEX protection so it should not be used in potentially explosive atmospheres powder flammable gases 18
18. ircuit Display LCD size 52 mm x 38 mm LCD with green backlight ON OFF Channels T1 T2 T3 TA T1 T2 Sensor type Type K thermocouple probe Type J T E R S thermocouple probe PT 100 ohm probe Cooperate with an 0 00385 alpha coefficient meet DIN IEC 751 Resolution 0 1 1 C 0 1 F 1 F Datalogger Auto 1 second to 3600 seconds Sampling Time Q Sampling time can set to 1 second Setting range but memory data may loss Manual Push the data logger button once will save data one time Q Set the sampling time to 0 second Manual mode can also select the 1 to 99 position Location no Memory SD memory card 1 GB to 16 GB Advanced Set clock time Year Month Date setting Hour Minute Second Decimal point of SD card setting Auto power OFF management Set beep Sound ON OFF Set temperature unit to C or F9 Set sampling time SD memory card Format PCE info tursdaletechnicalservices co uk PCE info tursdaletechnicalservices co uk Temperature Automatic temp compensation for the Compensation type K J T E R S thermometer Linear Linear Compensation for the full range Compensation Offset Available for Type K J T E R S and Adjustment Pt 100 ohm Probe Input Type K J T E R S Socket 2 pin thermocouple socket Pt 100 ohm Ear phone socket Over Indication show Data Hold Freeze the dis
19. nder the folder if the total files more than 99 files will generate a new route such as 4 The file s route structure TMAO01001 XLS TMA01002 XLS 01099 5 TMA02001 XLS TMAO02002 XLS 02099 5 Remark XX Max value is 10 6 Saving data from the SD card to the computer EXCEL software 1 After execute the Data Logger function take away the SD card out from the SD card socket 3 18 Fig 1 2 Plug in the SD card into the Computers SD card slot if your computer build in this installation or insert the SD card into the SD card adapter then connect the SD card adapter into the computer 3 Power ON the computer and run the EXCEL software Down load the saving data file for example the file name TMA01001 XLS TMA01002 XLS from the SD card to the computer The saving data will present into the EXCEL software screen for example as following EXCEL data screens then user can use those EXCEL data to make the further Data or Graphic analysis usefully 11 info tursdaletechnicalservices co uk EXCEL data screen for example Al ia B C D E a H I J K L M N Place IDate Time Value Unit Value Unit Value Unit Value Unit 2 1 2009 6 19 11 02 10 27 6 Tl KTemp 27 7 T2 KTemp 27 7 T3 KTemp 277 KTemp C 3 2 2009 6 19 11 02 11 27 6 Tl KTemp 27 7 T2 KTemp 27 7 T3 KTemp 277 KTemp C 4 3 2009 6 19 11 02 12
20. on the meter pressing the Power button once gt 2 sec will turn off the meter 2 Meter default Temp sensor type is Type K the display will show K indicator The default temperature unit is C F the method to change the Temp unit from C to F or F please refer to Chapter 7 5 page 18 3 Insert the Type K probes into the T1 T2 T3 T4 input socket 3 9 Fig 1 The LCD will show the 4 channels T1 T2 T3 T4 temperature value at the same time Ifthe certain channels do not insert the temperature probes the relative channel display will show over range 4 2 Type J T E R S measurement All the measuring procedures are same as the Type K section 4 1 except to select the Temp Sensor type to Type J K T E R S by pressing the Type Button 3 5 Fig 1 once in sequence until the up LCD display show J T E R S indicator 4 3 Pt 100 ohm measurement 1 All the measuring procedures are same as the Type K section 4 1 except to select the Temp Sensor type to Pt by pressing the Type Button 3 5 Fig 1 once in sequence until the right down LCD display show Pt text as 2 Insert the Pt 100 ohm probe optional PT 101 to PT1 input socket 3 10 Fig 1 PT2 input socket 3 11 Fig 1 The Pt 100 ohm measurement only allow max two channels two probes input 4 4 T1 T2 measurement If the meter already insert two probes Type K J T E R S T1 T2 input socket Pt 100 ohm PT1 PT2
21. once the LCD will show the text REC then press the Logger Button 3 8 Fig 1 the REC will flashing and beeper will sound at the same time the measuring data along the time information will be saved into the memory circuit Remark How to set the sampling time refer to Chapter 7 6 page 19 How to set the beeper sound is enable refer to Chapter 7 4 page 18 b Pause the datalogger During execute the Datalogger function if press the Logger Button 3 8 Fig 1 once will pause the Datalogger function stop to save the measuring data into the memory circuit temporally In the same time the text of REC will stop flashing Remark If press the Logger Button 3 8 Fig 1 once again will execute the Datalogger again the text of REC will flashing Finish the datalogger During pause the Datalogger press the REC Button 3 4 Fig 1 continuously at least two seconds the REC indicator will be disappeared and finish the Datalogger 5 3 Manual Datalogger Set sampling time 0 second a Set sampling time is to 0 second Press the REC Button 3 4 Fig 1 once the LCD will show the text REC then press the Logger Button 3 8 Fig 1 once the REC will flashing once and Beeper will sound once at the same time the measuring data along the time information and the Position no will be saved into the memory circuit Remark For the 4 channels measurement the right lowe
22. play reading Memory Recall Maximum amp Minimum value Sampling Time of Display Approx 1 second Data Output RS 232 USB PC computer interface Connect the optional RS232 cable UPCB 02 will get the RS232 plug Connect the optional USB cable USB 01 will get the USB plug Power off Auto shut off saves battery life or manual off by push button Operating 0 to 50 C Temperature Operating Less than 85 R H Humidity Power Supply Alkaline or heavy duty DC 1 5 V battery UM3 AA x 6 PCs or equivalent DC 9V adapter input AC DC power adapter is optional Power Current Normal operation w o SD card save data and LCD Backlight is OFF Approx DC 8 5 mA When SD card save the data but and LCD Backlight is OFF Approx DC 30 mA If LCD backlight on the power consumption will increase approx 14 mA Dimension Accessories Included Weight 489 g 1 08 LB 177 x 68 x 45 mm 7 0 x 2 7x 1 9 inch Instruction manual 1 PC info tursdaletechnicalservices co uk Optional Type K thermocouple probe Accessories TP 01 TP 02A TP 03 TP 04 Pt 100 ohm probe TP 101 SD Card 1 GB SD 2 GB USB cable USB 01 RS232 cable UPCB 02 Data Acquisition software SW U801 WIN AC to DC 9V adapter Hard carrying case CA 06 Soft carrying case CA 05A
23. r Display will show the Position Location no P1 P2 P99 and the T4 measurement value alternately a During execute the Manual Datalogger use the A Button 3 5 Fig 1 Button 3 6 Fig 1 to set the measuring position 1 to 99 for example room 1 to room 99 to identify the measurement location b Finish the Datalogger Press the REC Button 3 4 Fig 1 continuously at least two seconds the REC indication will be disappeared and finish the Datalogger 10 info tursdaletechnicalservices co uk 5 4 Check time information During the normal measurement not execute the Datalogger If press Time check Button 3 7 Fig 1 once the lower LCD display will present the time information of Year Month Date Hour Minute Second 5 5 Check sampling time information During the normal measurement not execute the Datalogger If press Sampling Button 3 8 Fig 1 once the lower LCD display will present the Sampling time information in second unit 5 6 SD Card Data structure 1 When the first time the SD card is used into the meter the SD card will generate a folder 01 2 If the first time to execute the Datalogger under the route will generate new file name TMAO1001 XLS After exist the Datalogger then execute again the data will save to the TMA01001 XLS until Data column reach to 30 000 columns then will generate a new file for example TMA01002 XLS 3 U

Download Pdf Manuals

image

Related Search

Related Contents

9630 Instructions  Asunto: Solicitud de apoyo para extensión de beca CONACYT de  Samsung GT-P6210 Наръчник за потребителя  AquaLabCX-2v3 AquaLab CX  MANUAL DE INSTRUÇõES - TA Triumph  Panasonic Advanced Hybrid System Telephone User Manual  SERVICE MANUAL  7800-A2-GB26-80 - Zhone Technologies  M-7 Technical Service Manual - Saratoga Spa Dealers Log In Page  American Standard 2460.XXXW Series User's Manual  