Home

eCONNECT PDU epSERIAL SOFTWARE USER MANUAL CPI

image

Contents

1. CHATSWORTH PRODUCTS techsupport chatsworth com www chatsworth com eConnect PDU epSerial Software User s Manual Version 3 0 April 2013 2013 Chatsworth Products Inc All rights reserved CPI CPI Passive Cooling GlobalFrame MegaFrame Saf T Grip Seismic Frame SlimFrame TeraFrame Cube iT Plus Evolution OnTrac Velocity and QuadraRack are federally registered trademarks of Chatsworth Products eConnect and Simply Efficient are trademarks of Chatsworth Products All other trademarks belong to their respective companies Rev 1 05 13 MKT 60020 584 eConnect PDU epSerial Software Manual Rev 3 April 2013 Table of Contents INTRODUCTION oi A aE 1 LEGALINFORMA TON acatar eiii don 1 WARRANT oA Sic 1 NOMENCLATURE to oa cia e eco do nieta 1 SOFTWARE OVERVIEW ccccecsceccccsccccsccccaceccccuceeeececeeesceeeanseeaeeaeneaneeeaesaeneass 2 INSTALLATION ona a a a ad 3 RUNNING EPSERIAL APPLICATION 2 cccececcccececccceccacececcaceceacececuaceneaueteneaesueacseatsneass 3 SELECTING Ac PD U a a r art ccensaietniadedeiaaaseanaties 4 MONITORING AP DU A A A A wave nsec 5 POIS ON FIG RATION escroto oo oido 6 NETWORK CONFIGURATION ccececcccecccccceccccccececccceaeaceceacececeueeavaceneuaneaeatsneacsueateneass 9 RECEPTACLE CONFIGURATION ccceccccececcccecccccceccceccaecceneaceceacsceaeaceneatsneceaueneansnss 10 GROUPS CONFIGURATION stent cies dicas carito incaico loteo tease pedra 11 LOGGING CONFIGURATION
2. 0 2ceccccececcccececccceccececcacecucecceccauececeaueceauscecusecescensaeenes 12 APPENDIX A CONNECTING AND LINKING PDUS c ccccccceeeececeeeeees 13 Chatsworth Products Inc CPI 0 eConnect PDU epSerial Software Manual Rev 3 April 2013 INTRODUCTION This document is the User s Manual for CPI eConnect PDU epSerial Software eConnect PDU epSerial Software User Manual 2013 Chatsworth Products Inc All rights reserved Legal Information The information contained in this guide is subject to change without notice Chatsworth Products Inc CPI shall not be liable for technical or editorial errors or omissions contained herein nor is it liable for any injury loss or incidental or consequential damages resulting from the furnishing performance or use of this material and equipment Warranty Chatsworth Products Inc CPI guarantees manufactured products and each part or component thereof against all defects in material and or workmanship CPI agrees to remedy any manufacturing defect either through replacement or repair at no charge provided that the defective unit is returned transportation prepaid to the CPI factory The warranty extends for a period of one year from the date of installation or initial use provided that this period shall not exceed 18 months from the original date of shipment from the factory Any product that has been repaired or replaced shall be similarly warranted on its r
3. No energy use has been recorded yet Energy Status 001003 PDU Name 1 BranchXx BranchY pBranchZ o m iO lt y m a O lt g m io lt 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 On single phase units outlets are divided into two branch groups Individual outlet port values are only listed on Monitored Pro and Switched Pro models The Clear button will reset values to zero Click on OK button to go back to the Main Menu PDU Configuration To configure the PDU select a PDU from the list and click on Configure button Configure the primary PDU first the first PDU listed in the Selected PDU combo box Network Settings are setup on the Primary PDU only m Connection Actions Selected PDU Com Part Monitor Configure comi y f Montor Coria 001 003 z Hn M Modules Present M Enviro 0 Enviro 1 P6 1P041 C3E Y RCM 0 iv MEM 22 V4 lv RCM 1 lv RCM 2 Disconnect Y BMM 0 Entered Normal Processing Loop The Basic Configuration screen next page will display Chatsworth Products Inc CPI 6 eConnect PDU epSerial Software Manual Rev 3 PDU PDU Name PDU Description Users Name 1 Name2 Name3 Password1 Password2 Password3 Permission 1 Permission2 Permission3 Ih Name Password4 Permission4 Notifications
4. SNMP SEMA Fixed Interval secs Alarm Interval secs Load Difference A Display Brightnes PDU Options Input Top Display Timeout min Login Timeout min Celsius Enable Web Primary PDU Disable Local Auth Environmental Limits Maximum Minimum Warn High Warn Low Probe 1 Temp F Probe 1 Name Probe 1 Humidity Probe 2 Temp F Probe 2 Humidity Probe 2 Name il il il il Branch A Limits Other Configurations Receptacles Groups Maximum Minimum Warn High Warn Low Voltage Network Ii Ii Ii i Current Logging AS Branch B Limits Maximum Minimum Warn High Warn Low Set Defaults Clear Load Voltage Current i i i HI Branch C Limits Maximum Minimum Warn High Warn Low Voltage Current il i HI HI The Basic Configuration screen on your model may vary There may be one two or three Branch A B C Limits boxes lower left corner and the Receptacles and Groups buttons under Other Configurations lower right side are not available on Monitored models Click on the Load button to get settings from the PDU Enter change settings as required or use Set Defaults to reset PDU to factory settings See the next page for field descriptions Click Save to change update settings Chatsworth Products Inc CPI eConnect PDU
5. ccess Hosts Trap Hosts Only I IPV4 IPV6 IPV6 IPV4 These Host1 0 0 0 0 Hosti 0 0 0 0 Hosts Host2 0 0 0 0 Host2 0 0 0 0 li Host3 0 0 0 0 Host3 0 0 0 0 l Community V3 Security Authentication Password HAJY Ms Write E Privacy Password A ERENS ESV EST USM User Context Name Engine ID SMTP Enable Port 465 Server Address 7 Server Options Always rt TLS JO E mail Address 0 Username l Password Redpientt Redet Repeta est Time Synch RFC Time Server NTP Time Server Radius Authentication AD Authentication Enable Server Port Shared Secret Enable Server Port Domain E 389 SEMA IPV4 Addr 192 168 123 1 IPV6 Addr Group Name ElBigSema Group Password sn Device Password Ports ConnListen 2001 ConnTalk 2902 BcastListen 2003 BcastTalk 2004 TTT TTT TTT yy Clear i Save Cancel You can enter detailed network configuration for IP Ports SNMP SMTP Time Synch Radius Authentication and AD Authentication here eConnect PDUs are not SEMA compatible at this time Do not change SEMA settings Click Save or Cancel if no new information was added or modified Chatsworth Products Inc CPI 9 eConnect PDU epSerial Software Manual Rev 3 April 2013 Receptacle Configuration From the Basic Configuration screen click the Receptacles button under the Other category for a detailed Receptacle Outlet Po
6. ck on the Connect button see above left The main screen below will display Serial port setting on the computer must be 9600 8 bit no parity 1 stop bit Connection Actions Selected PDU Com Port A Monitor Configure com Meni Conti joo1003 y m Modules Present Y Enviro D 7 Enviro 1 P6 1P041 C3E Y RCM 0 Y MCM ZE V1 lv RCM 1 lv RCM 2 Disconnect V BMM 0 Entered Normal Processing Loop Main screen Selecting A PDU The Serial Application will connect to the attached PDU If the PDU is linked to other PDUs using the PDU linking daisy chain feature the main screen will include a Selected PDU combo box in the Actions area See Appendix A for more information on linking PDUs Connection Actions Selected PDU Com Port Monitor Configure comi gt L Montar Coria oo1003 zi Modules Present V Enviro 0 l Enviro 1 P6 1P041 C3E Y RCM 0 iv MCM Liter V1 lv RCM 1 lv RCM 2 Disconnect MV BMM 0 Entered Normal Processing Loop Each PDU is assigned a different number The first PDU in the list is the primary PDU Linked PDUs are listed in order of attachment to the primary PDU To connect to another PDU select the PDU from the list and click Connect Chatsworth Products Inc CPI 4 eConnect PDU epSerial Software Manual Rev 3 April 2013 Monitoring A PDU To display the current temperature humidity and port status click on the Monitor button Depend
7. ental Units e Probe Temperature Humidity enter maximum and minimum values and alarm warning thresholds in degrees Fahrenheit and percentage of relative humidity default For degrees Celsius temperature check the Celsius box under PDU options above e Probe Names unique user defined name for each probe Branch A B C Units PDU may have one two or three branches e Voltage Current enter maximum and minimum values and alarm warning thresholds for Voltage and Current for each branch circuit on the PDU The PDU may have one two or three branch circults depending on model This example has three branch circuits Chatsworth Products Inc CPI 8 eConnect PDU epSerial Software Manual Rev 3 April 2013 Network Configuration From the Basic Configuration screen click the Network button under the Other Configurations category for the detailed Network Configuration screen Click on Load Network Configuration 001003 PDU Name IPV4 Settings m IPV6 Settings Enable Y Auto IPf AutoDNS EnablefY Global Address AutoIP AutoDNS IPAddr 192 168 123 123 NetMask 255 255 255 0 Addr NetMask 0 Gateway 192 168 123 1 DNS1 0 0 0 0 Gateway E DNS1 E DNS2 0 0 0 0 DNS2 gt m Services Telnet v Port 23 SSH Y Port 22 HTTP V Port 80 HTTPS V Port 443 SNMP m Ports Security Level Enable V QRY 161 TRAP 162 vifW vx V3 None V3 AuthNoPriv V3 AuthPriv J A
8. epSerial Software Manual Rev 3 April 2013 PDU e PDU Name and Description are unique user assigned values for the PDU Users e Local User Logins provides access to PDU using software e Permission is O to disable 3 for viewer 5 for control and 7 for admin Notifications e Fixed Interval How often measurements are sent via SNMP Trap e Alarm Interval Amount of time before alarm is sent via SNMP Trap after alarm condition e Load difference Amount of change in current that prompts intermediate SNMP Trap Display brightness e Controls the local display 0 9 with 9 as brightest Display timeout e Controls the local display How long display will stay on after use Login Timeout e Amount of idle time before software logs out and requires new login PDU Options e Input top Changes local display Flips display 180 so that it is easy to read when the PDU is mounted into the cabinet so that the power cord exist the top of the PDU e Celsius Changes temperature measurements from Environmental Probe to degrees Celsius Default setting is degrees Fahrenheit e Enable Web Allows access to PDU using Ethernet connection and web browser through HTTP or e Primary PDU Only selected if this PDU is linked is the first PDU in the daisy chain and is the PDU connected to the Ethernet or Serial Connection e Disable Local Auth No login required for Local Display or Web All users have view permissions Environm
9. epair or replacement for the remaining product warranty period or 90 days from the date of repair or replacement whichever expires last This warranty does not extend to products that have been subjected to neglect accident or improper use nor to units that have been altered by non CPI personnel No warranties other than those set forth in this section are given or implied with respect to the products furnished CPI shall in no event be liable for consequential damages for loss damage or expense directly or indirectly arising from the use of the products for any inability to use materials or from any other cause Nomenclature PDU eConnect Power Distribution Unit product Socket Receptacle Outlet Electrical output port Primary PDU PDUs can be linked to share one network connection When PDUs are linked together the Primary Role indicates the PDU that is attached to the monitoring computer and is the beginning of a daisy chain of up to 20 linked PDUs Secondary PDU Role assigned to a PDU that is 1 part of a PDU daisy chain a linked PDU attached to a primary PDU or 2 a stand alone operating PDU Chatsworth Products Inc CPI 1 eConnect PDU epSerial Software Manual Rev 3 April 2013 SOFTWARE OVERVIEW The epSerial application is a Microsoft Windows based application that can be used to configure monitor and control a single PDU or linked PDUs via the Serial port on the PDU The epSerial application is availab
10. ial Port to the next PDU s Daisy Chain In Serial Port 7 9 O O O z 10100 Temp Humidity e Continue this process linking the Out Port to the In Port for additional PDUs linking up to 20 PDUs e Using the setup buttons on the local display change the Role of the primary PDU from secondary the default to Primary in order to view the linked PDUs using the Serial Software Setup Menu IPv4 Network IPv6 Network Display POU Settings Exit e To access linked PDUs using a Serial Connection attach the Serial cable P N 35941 131 ordered separately between the Primary PDU s Daisy Chain In Serial Port and the computer that has the epSerial software installed e To access linked PDUs using the built in web interface refer to the eConnect PDU User Manual available for download on http www chatsworth com eConnect e For additional assistance contact US Tech Support 1 800 834 4969 techsupport chatsworth com Chatsworth Products Inc CPI 14
11. in the PDU Chatsworth Products Inc CPI 11 eConnect PDU epSerial Software Manual Rev 3 April 2013 Logging Configuration From the Basic Configuration screen click the Logging button under the Other Configurations category for a detailed data Logging Configuration screen Logging Configuration 001003 Options Y Enable Logging Feature Metrics Setup Changes Recep Group Outlet Changes Alarms User Changes User Login PDU State Changes V Firmware Upgrades Local Logging Interval 60 minutes Full Warning Level 75 External Logging Enable Log Server E Logging Server Address ee Server Port fo Option String Destination Directory fp User Name Password Save Cancel Activating the logging feature will keep a local record log of metrics alarms and PDU configuration changes The log file is saved on the local memory of the primary PDU Local memory is limited Log files can be downloaded for archiving onto a connected client computer or server New files will overwrite old files as local memory is filled e Options Select Enable Logging Feature to turn logging on Check the items that you wish to log Metrics are unit measurements voltage current power etc e Local Logging Designate the interval for recording metric data Log files are stored on the primary PDU s memory Local memory is limited so you can designate a warning based on percentage of use to p
12. ing on the PDU model the appropriate info will be displayed On single phase units outlets are divided into two branch groups Below is a sample of the display for a three phase Switched Pro PDU P N P6 1P0A1 Software Version 1 17 227 Temperature 70 8F Model P6 1P041 C3E Humidity dr is Alarm State None Branch Branchy BranchZ 0 04 0 00kw 0 00 0 04 0 00kw 0 00 O 0 04 0 00kw 0 00 P k P k Port P k 0 00 0 00 0 00 0 00 a 2 a adada aaa gt gt gt gt gt gt gt 2 2 a akk kk kk kis gt gt gt gt gt gt gt 2 Co v P v R v R v A v R v A v R v R If Environmental Probes P N 17761 001 or 17761 003 sold separately are attached to the PDU Temperature and Humidity will be displayed at the top of the screen Individual outlet port values are only listed on Monitored Pro and Switched Pro models From the Status screen you can view Voltage Current Power kW and Power Factor values On Switched or Switched Pro PDUs you can also turn outlets on or off Control check boxes and reset cycle power with R buttons Click on the Energy button at the bottom of the Status screen to see energy consumption in kilowatt hours kWh This is the sum of power used since the last clear reboot or reset Chatsworth Products Inc CPI 5 eConnect PDU epSerial Software Manual Rev 3 April 2013 Below is a sample of the Energy display for a three phase Switch Pro PDU P N P6 1FOA1
13. le for download on the CPI Website A Serial Setup Cable CPI P N 35941 131 ordered separately is required to attached the PDU to the computer running the epSerial application epSerial Software Features Access monitor and control up to 20 linked PDUs using a single direct serial cable connection to a computer running the epSerial software application Measure and monitor voltage current A power kW power factor and energy kilowatt hours for each branch circuit on each PDU the sum of all power used by PDU loads Measure and monitor voltage current A power kW and energy kilowatt hours on individual outlets on Monitored Pro and Swtiched Pro models the sum of all power used by specific PDU loads Turn outlets on or off and cycle power remotely on Switched and Switched Pro models set power on and cycle delays Set alarm warning thresholds for each branch on all models set alarm thresholds for each outlet on Monitored Pro and Switched Pro models Use as bench software to complete detailed IP setup before the PDU is attached to and monitored though a production Ethernet network includes setup of data and alarm logging and email notifications via an SMTP server functions Use as bench software to complete SNMP setup allows designation of separate Query and Trap Ports and assignment of separate Access Hosts and Trap Hosts IPs three each Chatsworth Products Inc CPI 2 eConnect PDU epSerial Software Manual Rev 3 A
14. pSerial Software Manual Rev 3 April 2013 Groups Configuration From the Basic Configuration screen click on the Groups button under the Other category for a detailed Group Configuration screen note that this screen is not available on Monitored PDUs which do not support per outlet monitoring and control Group Configuration 001003 PDU Name 1 y TD o x PDU ID Port MN N N pa k QJ NEO wo wo Ny N b S b amp 8 Y amp QI a E ooo O i A i f 7 E A A a 7 E E A A i f E A m O m i QI MN To view or modify an existing Group use the Select Group combo box in the lower right corner to select the group and click the Load button to load values from the PDU To create a new Group of receptacles outlets ports enter a Group name in the field at the top and the PDU ID and port number for each outlet in the group The Group can include outlets from multiple PDUs e PDU ID is the unique number assigned by the EPSerial exe software to each PDU at login The PDU ID for each PDU is included in the header of each menu For example 001003 is this PDU s ID e Port number is the number assigned to the outlet on the PDU See the Monitor page or Receptacle configuration tab Outlets are also numbered on the PDUs If PDUs are linked you can create Groups that include outlets from multiple PDUs Click Save Note that this will overwrite any values that are currently set
15. pril 2013 INSTALLATION The epSerial software application is available on the CPI website and link below http www chatsworth com Support and Downloads Downloads Software 1 In the download table Under the eConnect Power Distribution Units sub heading select the epSerial Application for download 2 Download the epSerial zip 3 Unzip to C CPl app folder The zip file includes three files epSerial exe epdigs dll and README txt 4 Follow the instructions in the README txt file to install the EPSerial exe application 5 Create a shortcut and place it on the desktop 6 Before using the application connect the serial cable P N 35941 131 ordered separately to the serial port of a computer and the serial port In of the PDU Connect the cable to the Primary PDU when several PDUs are linked If your computer does not have a Serial port then use a USB Serial Adapter not included with serial cable ordered separately See Appendix A for more details Running epSerial application Double click the epSerial Icon on the Desktop ES EP Serial When the application opens see below left select the L button next to the Com Port combo box to enter the Login Credentials below right The default is admin admin Click OK Connection Com Port mm gt 4 a Name admin Chatsworth Products Inc CPI 3 eConnect PDU epSerial Software Manual Rev 3 April 2013 Select the appropriate COM Port and cli
16. rompt a log download e External Logging When the PDU has an Ethernet connection you can store log files on a server that is accessible to the PDU Checking Auto Transfer will copy a log file to the server every six hours as long as the connection is available e Save settings to begin logging Chatsworth Products Inc CPI 12 eConnect PDU epSerial Software Manual Rev 3 April 2013 APPENDIX A CONNECTING AND LINKING PDUS Connect the PDU directly to a computer with the epSerial application using the Serial Setup Cable CPI P N 35941 131 ordered separately The cable has an RJ45 connector on one end and a DB9 connector on the other end Attach the RJ45 connector to the Daisy Chain In Serial Port on the PDU Attach the DB9 connector to the computer or use an USB to DB9 adapter if the computer does not have a DB9 connector USB port Daisy Chain In Serial Port Daisy Chain Out Serial Port Ethernet Port Environmental Push buttons for matching Icons in the LCD POU Total Status LED You can link daisy chain up to 20 PDUs together 1 Primary and 19 Secondary and access all of the PDUs from a single Ethernet network or direct serial connection to the Primary PDU Chatsworth Products Inc CPI 13 eConnect PDU epSerial Software Manual Rev 3 April 2013 To link PDUs e Connect a standard Cat 5 6 four pair network patch cord or network cable with RJ45 connectors from the Primary PDU s Daisy Chain Out Ser
17. rt Configuration screen note that this screen is not available on Monitored PDUs which do not support per outlet monitoring and control Receptacle Configuration Select Branch v Delays secs Current Limits Amps Name ption PowerON Reset ON OFF Maximum Minimum WarnHigh WarnLow OutletName 1 one mem 3 lv 0 0 QutletName3 Outlet3 Description _ 16 OutletNamei6 Outlet16 Description 040000000001 eS Clear Load 0 0 lt I lt l 0 0 lt lt I Jaa Jaa E EEEE a a xI hal hai aa BE 5s DE E ls Pp is DE fs Cancel i Use the Select Branch combo box in the top left corner to select the branch corresponding outlets are listed Outlets are also numbered and color coded on the PDU Click the Load button to load values from the PDU or enter new values e Name and Description unique customer assigned values e Delays on Switched and Switched Pro models only set per outlet power on and reset delays so that power is gradually restored to reduce inrush current e On Off turn outlet on when checked off when not checked Allows unused outlets to be turned off to prevent unauthorized use of power and unplanned loads e Current Limits enter maximum and minimum values and alarm warning thresholds for Current for each outlet on the PDU Click Save Note that this will overwrite any values that are currently set in the PDU Chatsworth Products Inc CPI 10 eConnect PDU e

Download Pdf Manuals

image

Related Search

Related Contents

Wagner 0530002 Instructions / Assembly  User Manual - GPS Golf Watch  POUSSIERES (12 pages) margo ohayon POUSSIERES Ecrire signe  MPX-70 - Roland DGA Corporation  CS・B双方向CATV用    Dataram PC3-10600 16GB  KODAK EASYSHARE DX3900 Digitale Zoomkamera  User Manual - Microinvest eMenu Pro  télécharger l`article  