BARCODE READER
Contents
1. KEYBOARD WEDGE PC AT PS 2 RS 232 SERIAL RS 232 TO KB WEDGE WAND EMULATION OCIA TX Wand Emulation as Code 39 TX Wand Emulation as as EAN Scan this code then scan 1 2 or 3 from the ASCII table to indicate the mode you whant to use AUTO EAN 8 or EAN 13 then scan this code once more BARCODE SIMBOLOGY Symbologies Selection CODE 39 ENABLE CODE 39 DISABLE FULL ASCII CODE 39 STANDARD CODE 39 CODE 128 DISABLE CODE 128 ENABLE CODE 93 DISABLE CODE 93 ENABLE m CODE 32 DISABLE ISBN DISABLE ISBN ENABLE Symbology Setting I 2 5 1 2 5 DISABLE 1 2 5 ENABLE FIXED LENGTH ON ES DIGIT SUPPRESS LAST DIGIT SUPPRESS NO DIGIT SUPPRESS Symbology Setting CODE 128 EAN 128 DISABLE EAN 128 ENABLE EAN 128 SEPAR SET CHECK DIGIT DISABLE CHECK DIGIT ENABLE 10 Symbology Setting S 2 5 5 2 5 DISABLE VERIFY CHK DIGIT S 2 5 ENABLE FIXED LENGTH FIXED LENGTH OFF ADD CHK DIGIT DON T ADD CHK DIGIT 11 Sym
2. amp Il 0 3 35 ASCII TABLE 5 Il 6 1 7 8 9 lt gt 1 A B C D E F G Il H J 36 ASCII TABLE K L M N O a Il 5 Il U X Y Il Z 37 ASCII TABLE b d Il e Il f 9 h i j k n 0 p q Il r 5 t u V 38 ASCII TABLE w x y z STX ETX m 5 UJ m g r Tm 5 39 ASCII TABLE CR ee m on g m m p 2 40 ASCII TABLE RIGHT CTRL 41
3. Data Length mee Preamble Postamble rose USER DEFINED DEFAULT PREAMBLE 24 Define Code ID DEFINE CODE ID CODE 39 FULL ASCII CODE 39 STANDARD EAN 13 UPC A EAN 8 UPC E 12 5 25 Define Code ID CODABAR CODE 128 CODE 93 S 2 5 MSI CODE 11 26 Custom Code Editing SELECT FROM LEFT SELECT FROM RIGHT Scan SET EDIT MODE Scan LEFT or RIGHT then scan 2 digits from the ASCII table to select the required length and scan LEFT or RIGHT once more CUSTOM MODE ENAB Enable above setting CUSTOM MODE DISAB Disable above setting FULL DATA EDIT DISAB Disable following setup FULL DATA EDIT SETUP Scan FULL DATA EDIT SETUP then scan 2 digits from the ASCII table to select the start position scan the Character and 2 more digits as the required string length close this procedure by scanning once more the above barcode 27 READER FUNCTIONS Laser ON timeout som MEDIUM coro Scan the above barcode then scan 1 2 3 from the ASCII table to select how attempt the decoder should do before a good read
4. II on START STOP NOT SENT 17 Symbology Setting MSI MSI DISABLE MSI ENABLE DOUBLE MOD 10 SINGLE MOD 10 MOD 11 PLUS MOD 10 NOT SENT 18 Symbology Setting CODE 11 sorse CODE 11 DISABLE CODE 11 ENABLE ONE CHECK DIGITS 19 RS 232 SERIAL PARAMETERS Baud Rate 300 1200 2400 4800 9600 19200 38400 20 Data Bits ACK NACK protocol EVEN ODD MARK SPACE NONE 7 BITS 8 BITS OFF ON 21 RS 232 additional parameters CTS RTS DISABLE CTS RTS ENABLE RS 485 ENABLE LRC ENABLE RS 485 DISABLE LRC DISABLE 22 RS 232 TO KBD WEDGE PARAMETERS Conversion modes and terminator status DATA FORMAT Terminators COUNTER ENABLE COUNTER SET 01 99 DEFAULT 15 CODE ENABLE CODE SET ASCII CODE 01 7F TERMINATOR PASS TERMINATOR CUT ENTER CR LF FIELD EXIT CR RETURN LF NONE 23 Code ID
5. US BARCODE BARCODE READER INSTALLATION OF YOUR DEVICE PS 2 Connection RS 232 Connection need 5Volts power supply INSTALLATION OF YOUR DEVICE USB Connection USING THIS MANUAL TO SETUP YOUR DEVICE To set up all the necessary functions you can use the following barcode menus Using these barcodes you should enter in program mode scan the required command symbol then exit from program mode The general procedure is the following 1 Scan the command symbol PROGRAM 2 Scan one or more parameters 3 Scan the command symbol END note Code 2 5 symbologies have an unchecked reading mode so that you could set a fixed code length to avoid any reading errors Following is the correct procedure 1 Scan the command symbol PROGRAM 2 Scan the command symbol FIXED LENGTH 3 Scan the command symbol END The first two scanned barcodes 2 5 will be stored as fixed length values The following procedure will reset the above selection 1 Scan the command symbol PROGRAM 2 Scan the command symbol FIXED LENGTH OFF 3 Scan the command symbol END COMPLEX DEVICE SETTINGS Set MIN MAX barcode lengt 1 Scan the command symbol PROGRAM 2 Scan the symbol SET MAX amp MIN 3 Scan barcode symbology i2 5 39 etc 4 Scan the symbol or NN max or min 5 Scan 2 digits from the ASCII table 6 Scan the symbol
6. SET MAX amp MIN 7 Scan the command symbol END Set PREAMBLE POSTAMBLE 1 Scan the command symbol PROGRAM 2 Scan the symbol PREAMBLE POSTAMBLE 3 Scan up to 16 characters from the ASCII table 4 Scan the symbol PREAMBLE POSTAMBLE 5 Scan the command symbol END Set RS 232 to KEYBOARD WEDGE 1 Scan the command symbol PROGRAM 2 Scan the symbol RS 232 TO KB WEDGE 3 Scan the RS 232 parameters bps data parity 4 Scan the RX modes a COUNTER ENABLE wait for a fixed number of characters to convert the received message b CODE ENABLE wait for an ASCII character as record terminator to convert the received message 5a Scan the command symbol COUNTER SET scan 3 digits from the ASCII table then scan once more the command symbol CODE SET 5b Scan the command symbol CODE SET scan the characters you whant to set as RX message terminator from the ASCII table then scan once more the command symbol CODE SET 6 Scan the command symbol END COMPATIBLE PRODUCTS This manual could be used to setup the decoder section of the following EIA products FORCE CCD SCANNER ROCK LASER SCANNER THUNDER PORTABLE TERMINAL OTHER FUTURE MODELS PARAMETERS SETTING ENTER EXIT SETUP gt ver cone evase PROGRAM DEFAULT END VO INTERFACE Device amp Interface Selection
7. bology Setting UPC A UPC A DISABLE UPC A ENABLE LEADING DIGIT SEND LDNG DIGIT NOT SENT ADD CHK DIGIT DON T ADD CHK DIGIT 12 Symbology Setting UPC E UPC E DISABLE nne LEADING DIGIT SEND LDNG DIGIT NOT SENT ADD CHK DIGIT DON T ADD CHK DIGIT ZERO EXP ENABLE ZERO EXP DISABLE 13 Symbology Setting EAN 8 IMI ose LEADING DIGIT SEND LDNG DIGIT NOT SENT DON T ADD CHK DIGIT 14 Symbology Setting EAN 13 EAN 13 DISABLE EAN 13 ENABLE LEADING DIGIT SEND LDNG DIGIT NOT SENT ADD CHK DIGIT DON T ADD CHK DIGIT 15 Symbology Setting EAN UPC SUPPLEMENTAL 2 DIGIT SUPPL DISAB 2 DIGIT SUPPL ENAB 5 DIGIT SUPPL DISAB 5 DIGIT SUPPL ENAB SPACE SEPARATOR ON SPACE SEPAR OFF TRANSMIT IF PRESENT MUST PRESENT 16 Symbology Setting CODABAR INIT ET
8. ing then scan thi barcode once more to close this procedure SCURITY LEVEL Redudancy on decoding 28 Beep Tone on decoding eme Reading mode HIGH Switch mode Flash mode Repeat mode 29 Intercharacter delay 5 one sons UI sons Intermessage delay cono I 50 ms 200 ms 31 KBD WEDGE PARAMETERS Function codes Upper Lower case mom moe Num lock emulation om 9 FF 32 Keyboard language TET sess TET NORWEGIAN ITALIAN GERMAN 33 BARCODE LENGTH PARAMETER Barcode Fixed length SET MAX amp MIN CODE 39 1 64 1 2 5 4 64 S 2 5 4 64 CODE 128 4 64 MSI 4 16 CODE 93 4 64 CODE 11 4 64 CODABAR 4 64 MAX MM MIN NN 34 ASCII TABLE