1. 7 kgs 3 2 Declaration of Product Performance Optical radiation of this luminaire conforms to the requirements by the EXAMPT GROUP OF IEC6247 1 2006 4 Installation 4 1 Street light installment 4 1 1 Installation Connect the cable of pole with the input cable of street light browse cable butt joint with power grid L blue butt joint with power grid G coil bulking the corresponding core wire put the joint into the terminals then use terminals fastening as shown in figure one and the last used waterproof tape or electrical tape wrapped the terminals Connected the yellow and green cable to earth wire Connect brown cable to power grid L onnect blue cable to power grid N Cable of pole l Cable of fixture input 4 1 2 Insert the pole into the mounting hole adjust the illuminate surface of fixture then locked the tabletting firmly as shown in figure 2 asten the screw Fasten the screw 4 2 Solar LED street light installment 4 2 1 Connected the corresponding cable of pole with the input cable as shown in figure 3 the brown input cbale is the positive pole of power supply black is the negative pole coil bulking the corresponding core wire put the joint into the terminals then use terminals fastening as shown in figure one and the last used waterproof tape or electrical tape wrapped the terminals Black cable is negative pole of power supply Brown cable is negative pole
2. of power supply 4 2 3 Insert the pole into the mounting hole adjust the illuminate surface of fixture then locked the tabletting firmly as shown in figure 2 4 2 4 After the fixture installed connect the corresponding core wire of connecting line of pole with the corresponding positive pole and negative pole of power input 5 Transportation amp Storage 5 1 During transportation severe mechanical impact solarization amp drench should be avoided the luminaire could not be placed upside down strongly against throwing rolling and hard press 5 2 Storage warehouse should be dry clean and draughty No corrosive medium ambient temperature should be around 0 40 C keep away from fire and heat source 6 Open Package and Inspection Before you open the package check if there s any damage of the carton After opening the carton please check the enclosed technical data sheet such as User Manual etc and confirm all the accessories are safe and sound 7 The dos and don ts 7 1 Read the Instruction carefully before using the product 7 2 Before installation make sure the luminaire and all accessories are perfect no damage 7 3 Before installation must switch off the power grid live line work is strictly prohibited 7 4 Handle with care amp Make sure Wiring is correct 7 5 To assure LED Module lifespan please do not change the power supply by yourself 7 6 To assure safety of power supply and better effect of lighting prote
3. Operating Instruction Manual for CH LLDXXX XX XXX G J Ill C B02 Thanks for using our products Read the Operation Manual carefully before using the product 1 Summary 1 1 Product Features High power LED Street Light Energy saving Green amp eco friendly Long life span 1 2 Applications Roads Plazas Outdoor Leisure Places Parks Schools and courtyard 1 3 Operation Temp 30 C 50 C 1 4 Model No Formulation Chex Lek Poe ee ae Lex X LL Extend Code A digit Omissible Serial No Letter A B C IP Grade A IP67 B IP66 C IP65 D IP54 Rank of Luminance Efficiency 1 II HI IV descending order Light spot shape Rectangular J Circle Y Oval T Batwing S Average CCT Natural White G Warm white D Input Voltage V Digit Electric Current AC DC Luminaire Rated Power W Digit Luminaire LLD Street Light LTG LED Flood Light LGK Canopy Light Company Name CHINAHONG 1 5 Certificates UL Approved No E343102 CE Approved No ATE20102095 1S09001 Cert No 04110020110ROS 1S014001 Cert No 04110E20037ROS 1 6 Standards CIE140 2000 Road Lighting Calculations CIE121 1996 Photometry and Goniophotometry of Luminaires IEC 60598 2 3 2002 Particular Requirement Luminaires for Road and Street Lighting IEC 60598 1 2003 General Requirement and Tests 2 Product Structure Characteristics Waterproof heat shunt Structure which ensures LED Module works
4. ction earth line between Power supply and Power grid are well connected In case of power grid without earth line the earth line of power supply should be connected with the lamp post 7 7 This is a maintenance free product in case of maintenance is needed please contact us 7 8 After installation please confirm the luminaire is fixed firmly to the lamp post
5. under a safe and reliable environment furthermore this helps to reduce light degradation and improve LED Lifespan The structure also features a 1 reflector of light distribution principle improvement of light distribution extending of lighting scope and better visual effect 3 Technical Data Sheet 3 1 Parameters S N Specifications Solar Input Volt Current DC24 oDC12 Power Rated Power 24 036 048 060 072 096 120 Input Volt Current 220V 0c0 32A 10 43A 0 53A Rated Power 60W 80W 100W Power 1 Supply Output Constant DC30 36V 3 8A 4 5A 5 2A Series Power Current Supply Input Frequency 50 60HZ Conversion 90 Efficiency Power Factor 0 92 2 CCT 2700 6500K 24W gt 1700Im 36W gt 2500 Im 48W gt 3400 Im 60W gt 4300 Im Luminou 3 72W gt 5100 Im Flux 80W gt 5700 Im 96W gt 6900 Im 100W gt 7200 Im 120W gt 8400 Im 4 Operating Temp 30 50 C 5 Anti wind Capability 2188 km h 6 IP Grade IP65 7 Installation elevation 10 15 degrees 8 Bolts Torque lt 46 Nm 9 Tempered Glass Cover 311 230 5 34mm material SiO2 10 Maximum Temperature of Heat Sink 58 C 11 Overall dimension 608 312 166 mm 12 Net Weight 13
Download Pdf Manuals
Related Search
Related Contents
Eclipse 1, 2, 3 et 4 Manuel d`installation et de fonctionnement user manual. - PCE Instruments RESTAURATION PAR COURONNES ET BRIDGES BEDIENUNGSANLEITUNG - Icon Heath & Fitness MFJ-462B MultiReaderTM ALDEKOL DES - Halag Chemie AG Manual VMB TL-A220 (v.07.14) SPW-1 Onwer`s Manual Aluratek Slim Color Folio w/ Bluetooth KB Copyright © All rights reserved.