1. gt Using the slotted screwdriver connect the other end of the 2 wire cable to the grey plug connection on the Netbiter DC Power Monitor paying close attention to the poles Continued overleaf Rev 1 00 netbiter argos m i a D iter argos installation Guide netbiter Netbiter DC Power Monitor Connect Modbus wire A black to 6a Pin 1 of the Modbus connector Modbus Connectors for the 24 VDC power supply and Connect Modbus wire B white to Modbus are located on the top of the Net 6b Pin 2 middle pin of the Modbus biter DC Power Monitor connector Connect OV to the terminal of 6c For further information see also the power supply connector Netbiter EasyConnect User Manual Connect 24V to the terminal of 6d the power supply connector Power The selector screw on the front of the unit provides quick setting of tb iter selector Modbus ID 15 different Modbus ID s See the ne I er Position table to the right 0 Modus ID 1 or other ID via software 1 Modbus ID 31 Any other Modbus ID must be set Power 5 Modbus ID 32 from software Set this screw to 0 Modbus ID 1 by default and Status 3 Modbus ID 33 contact HMS support for further 4 Modbus ID 34 information 5 Modbus ID 35 6 Modbus ID 36 15 Modbus ID 45 All other device settings are available at Netbiter Argos after the DC Power Monitor has been added to a user account using a device template or device pr
2. netbiter argos compatible Check package contents 1 x DC Power Monitor 1 x Hall sensor 2m cable 1 x Temperature sensor 1 x Installation Guide Mount the hall sensor on the power wire of the load to be measured Observe the sensor orientation In the example here the sen sor vane should point towards the load and away from the power source or rectifier Use a cable strap to fix the sensor in place 3a At the other end of the cable insert the green push connector into the socket to the right on the underside of the Netbiter DC Power Monitor as shown here 3b Mount the temperature sensor in the required location not shown here 4a 5b To set up voltage measurement connect a 2 wire cable to the site equipment to be measured not shown here 5a Important The voltage connection must be fused max 10A using an inline fuse holder AS Doc ID SP1570 Installation Guide Netbiter DC Power Monitor A12277 ADIATOR AB en At the other end of the cable insert the green push connector into the socket to the left on the underside of the Netbiter DC Power Monitor as shown here netbiter Mount the DC Power Monitor in a free space ona DIN rail Pull down on release catch to mount This example shows a load with negative earth To measure a load with positive earth the sensor must be mounted the other way round 24 VDC Rectifier or Power Source
3. ofile Please see the Netbiter Argos Administration Manual for further details Modbus Address Description 1 Measured current f Time constant in seconds for overconsumption alarms i Mean EC NONARE Allowed settings 60 120 180 240 300 600 900 1800 3600 3 Measured watts 10 Temperature Over consumption alarm 1 will be triggered when the average 20 Total Wh consumed energy exceeds this level within the time period 22 Total Wiincomine specified in Overconsumption Time Factor 24 Total Wh Outgoing Over consumption alarm 2 will be triggered when the average 26 Delta In Out Wh i aig se overcharging energy exceeds this level within the time period 30 Aarm specified in Overconsumption Time Factor 52 Overconsumption time factor 53 OC1 Power setting 54 OC2 Power setting Doc ID SP1570 Rev 1 00
Download Pdf Manuals
Related Search
Related Contents
atención Acer 510 Series Laptop User Manual Downloading termostufa a pellet diva - Poêles en Direct Spirit® Portatile - Chart Industries MANUAL DEL USUARIO DEL KITE ESPAÑOL Xerox 180 NPS Printer User Manual 3 - Nuova Elva Sandberg LUX-LINE, S-Video M-M 5 m Copyright © All rights reserved.
Failed to retrieve file