Caddx 8900 Manual - Affordable Security and Protection

image

Contents

1. FIRE Steady siren or pulsing bell INTRUSION amp PANIC Yelp siren or steady bell when programmed with Audible capability KEYPAD CONTROL LIGHT INDICATORS ARMED READY INSTANT POWER ZONES 1 6 RED On when system is armed off otherwise Flashes for alarm memory if alarm was activated during arming cycle GREEN On when all zones are secure or and or Bypassed and the system is ready to arm off otherwise RED On when the entry exit zones are instant off otherwise RED On when AC power is on off otherwise YELLOW Flashing means unsecured Steady means bypassed Off means secure KEYPAD CONTROL TONES BEEPS A sounder is built into the keypad and may sound for any of the following reasons Beeps for all keypresses Sounds a continuous tone during the Entry delay time Pulses when a dayzone is violated while the system is disarmed Pulses when a FIRE zone has a trouble condition Pulses when the armed status changes and the AC power is off Beeps 3 times for trying to arm with the READY light off if FORCE ARMING has not been selected Beeps 1 second for the CHIME feature Beeps 1 second at the end of the exit delay When pulsing the keypad sounder may be silenced by entering a valid code The arm disarm state of your system will not change when entering a code to silence a pulsing keypad sounder RESETTING YOUR SECURITY CONTROL CENTER In the event of a system malfunction in the Secur
2. instant option has been selected by your installing company you may arm your security system and not exit through a normal entry exit door remaining inside When this occurs all interior zones are automatically bypassed This allows freedom of movement within the home business while the security system is armed and all assigned exit delay zones become instant will cause an instant alarm signal if opened The red INSTANT light on the Keypad Control will be illuminated at the end of the delay time to indicate that the Instant mode has been activated The entry delay can be activated or deactivated by pressing the key If any protected perimeter door or window is opened the security system will sound and report if so programmed immediately The Security System is disarmed in a normal fashion by entering a valid four digit code L MANUAL PANIC HOLD UP ALARM When the gt and pound keys are pressed at the same time for one 910 second the local audible alarm will sound If your system is connected to a monitoring center an emergency report could be transmitted to that center These keys should only be pressed in an emergency situation requiring immediate response by law enforcement personnel PLEASE NOTE Some Panic Hold up alarms are programmed to be silent at the protected building while reporting an alarm to the monitoring center Check with your installing company to determine how your Security System will respond
3. BER READ THE ENTIRE MANUAL AND IF POSSIBLE PRACTICE ON THE KEYPAD CONTROL WHILE YOUR PROFESSIONAL INSTALLER IS AT YOUR BUILDING IF YOU HAVE ANY QUESTIONS ASK YOUR INSTALLING COMPANY PLEASE KEEP IN MIND THAT THE LEVEL OF SECURITY YOU WILL OBTAIN WITH THIS SYSTEM RELATES SPECIFICALLY WITH TWO MAJOR FACTORS 1 The quantity quality and placement of security devices attached to this system 2 The knowledge you have of the security system and how that knowledge is utilized in a weekly test of the complete system YOU SHOULD BE AWARE OF THE FOLLOWING FACTS AND USE THEM WHEN PREPARING A SAFETY SECURITY PLAN FOR YOUR HOME BUSINESS e Your security system is an electronic device and is subject to failure or malfunction Do not rely on it as your single source of security e Your system should be tested weekly e Your system will not work without power e Warning devices will need to be loud enough wired correctly and properly placed to provide notification of an alarm event e Smoke and heat detectors may not detect heat and smoke in all situations e Use qualified security professionals to select install and maintain your security system e It may be possible to arm the security system without the backup battery connected Your periodic test should be done with A C Power removed to verify the battery is connected and adequately charged e Care should be taken to plug in and properly restrain the A C Transformer after testing
4. Code 1 can assign or change auxiliary codes CHANGING THE MASTER CODE The Master Code is User Code 1 and must be programmed by referring to it as code 1 For example if the Master code is 1 2 3 4 and you want to change it to 5 3 4 2 the programming sequence would be as follows Press 1 this enters programming for user 1 then enter the current Master Code of 1 2 3 4 now press 1 to verifying that user code 1 is being changed then enter your new Master Code of 5 3 4 2 Now end the sequence by pressing 1 to exit programming The entire sequence would consist of pressing 17 keys as follows DEI HE 1H2 HSHA PRETI ISHSHAF2 91 11 1 14 IMPORTANT Changing the Master Code will invalidate your Duress Code and all auxiliary codes After changing the Master code you must reprogram these codes PROGRAMMING AUXILIARY CODES In order to program Auxiliary Codes you must know the Master Code As stated earlier each Auxiliary Code has its own unique number from 2 thru 7 and must be referred to by its number It is programmed much like the Master Code For example to program Auxiliary user code 2 the sequence would be as follows DKIH21 8 11 121 181 14 2 H HL HE 1 HATTE New Code REMOVING AUXILIARY CODES To remove an Auxiliary Code simply program it to be the Master Code For example to remove User Code 2 the sequence would be as
5. PLEASE READ THIS ENTIRE BOOKLET CAREFULLY BEFORE OPERATING YOUR SECURITY CONTROL SYSTEM IF YOU DO NOT UNDERSTAND ANY PORTION OF THIS MANUAL OR IF YOU HAVE ANY QUESTIONS ABOUT YOUR SYSTEM CONTACT THE INSTALLING COMPANY LISTED ON PAGE 1 OF THIS BOOKLET HOW TO ARM YOUR SECURITY SYSTEM To Arm the security system close all of the protected doors and windows The green READY light on the keypad control will be illuminated when all of the protected zones and sensors are secure If any of the zones are bypassed a sensor in that zone can be violated without affecting the READY light The security system will not arm if the READY light is not illuminated With the READY light on you may arm the security system with your Master Code or one of the Auxiliary codes Each time a key is pressed on the keypad control a short tone beep will sound If the keypad beeps three times after a code entry or it does not arm it is an indication that the code has not been accepted Press the key to reset and re enter a valid code If an error is made during code entry press key and re enter the code If the keypad control beeps continuously after code entry it is an indication that 1 the POWER light is off meaning there is no AC power to your system or 2 a faulted fire zone The keypad sounder can be silenced by re entering your four digit code If the POWER light is off you should restore power to the system if possible If you a
6. SECURITY SYSTEM NOTES Installing Service Company For Service Call SPECIAL CODES Master Code________ Duress Code Security System Configuration Auxiliary Code s Quick Arm Digit 2 9 3 10 4 11 5 12 6 13 7 14 8 15 Exit Delay Time Entry Delay Time Fire Alarm Sound Steady Siren i Pulsing Bell Burglar Alarm Sound Yelp Siren A Steady Bell Zone Coverage Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Emergency Phone Numbers Fire Dept Police Dept THIS MANUAL IS FURNISHED TO HELP YOU UNDERSTAND YOUR SECURITY SYSTEM AND BECOME PROFICIENT IN ITS OPERATION ALL USERS OF YOUR SECURITY SYSTEM SHOULD READ AND FOLLOW THE INSTRUCTIONS AND PRECAUTIONS IN THIS BOOKLET FAILURE TO DO SO COULD RESULT IN THE SECURITY SYSTEM NOT WORKING PROPERLY THIS BOOKLET SHOULD BE KEPT IN AN ACCESSIBLE LOCATION FOR THE LIFE OF THE SECURITY SYSTEM IF YOU DO NOT UNDERSTAND ANY PART OF THIS MANUAL YOU SHOULD NOTIFY YOUR INSTALLING COMPANY AND ASK FOR THAT SECTION OF THE MANUAL TO BE EXPLAINED FULLY The SECURITY CONTROL CENTER is turned on ARMED and off DISARMED by entering a 4 digit code into the Keypad Control which is similar to a telephone keypad The Keypad Control includes 10 indicator lights and a built in electronic sounder These provide specific information relating to the status of the security system which is described in this booklet Understanding what the lights and sounds mean will hep you o easily operate your system SO REMEM
7. er the installation of your Security System has been completed notify your local Fire and Police Departments to give them your name and address for their records Early warning fire detection is best achieved by the installation of fire detection equipment in all rooms This equipment should be installed in accordance with the National Fire Protection Association s Standard 74 For additional information write the National Fire Protection Association Batterymarch Park Quincy MA 02269 The following are examples of evacuation plans A plan unique to your home or business should be drawn and memorized by each occupant 10 8900 DLX USER S MANUAL 8900DLXUB97 REV B 5 15 97
8. follows 2 5 3 4 2 2 5 3 4 2 KTH21 T User Code 2 has now been eliminated TESTING YOUR SECURITY SYSTEM There are several tests you should perform on a periodic basis at least once a week to insure that your Security System is functioning properly Enable the CHIME Feature and open all protected windows and doors The Keypad Control should sound beep for each device and the appropriate yellow zone light should blink Walk into all areas protected by motion detection devices while someone observes the Keypad Control The appropriate yellow zone light should blink for each sensor tested If your system has a FIRE Zone the Smoke or Heat detectors should be tested at least monthly If your Security System is m9onitored by a Central Monitoring Station always call before to let them know that you are about to conduct a test of the fire detection system Always call after the test to ask for results and to put your fire detection system back into service If the Siren Bell test option has been selected by your installing company you may activate the siren bell by pressing the one 1 and the seven 7 keys at the same time for one second To silence the siren bell enter your 4 digit Master or Auxiliary Code If any of the above tests are not successful or the results unclear contact your service company at the phone number listed on page 1 of this booklet AUDIBLE ALARM SOUNDS
9. gnated as FIRE zones and or smoke detectors press the key reset on the keypad After 10 seconds the zone LEDs designated as FIRE zones should extinguish and the light on the affected smoke detector should go out If you are unable to reset the LEDs for designated FIRE zones or smoke detectors after all smoke has cleared you should immediately call the service phone number listed on page 1 of this booklet FIRE ZONE TROUBLE If the red TROUBLE light becomes illuminated it is an indication of a technical problem with the Fire Zone Enter a valid code to silence the keypad sounder beeper and press the RESET key If the TROUBLE light does not go out after 10 seconds you should call the service phone number listed on page 1 of this booklet L DURESS CODE If checked your security system has a DURESS CODE option If so this code may be programmed to send a special message to the central monitoring station if you are forced to arm or disarm your security system against your will Check with your Installing Servicing company to see if this option has been enabled for your system PROGRAMMING ACCESS CODES The security system can be armed and disarmed by the Master code User Code 1 and up to 6 auxiliary codes All codes must have 4 digits These Auxiliary codes are individually numbered from 2 to 7 If Auxiliary codes are desired they must be programmed individually Only persons knowing the Master Code User
10. ity Control Center press the reset key located on the Keypad Control for one 1 second This should reset the code sequence and restore normal operation If the problem persists call the service number located on page 1 of this booklet for service EMERGENCY EVACUATION PLANS An emergency evacuation plan should be established for an actual fire alarm condition For example the following steps are recommended by the National Fire Protection Association and can be used as a guide in establishing an evacuation plan for your building Draw up a floor plan of your home Show windows doors stairs and rooftops that can be used for escape Indicate each occupant s escape routes Always keep these routes free from obstruction Determine two means of escape from each room One will be the normal exit from the building The other may be a window that opens easily An escape ladder may have to be located near the window if there is a long drop to the ground below Set a meeting place outdoors for a headcount of the building occupants Practice escape procedures In a home sleep with bedroom door closed this will increase your escape time If you suspect fire test the door for heat If you think it is safe brace your shoulder against the door and open it cautiously Be ready to slam the door if smoke or heat rush in Practice escaping to the outdoors and meeting in an assigned spot Call the Fire Department from a neighbor s phone NOTE Aft
11. re unable to correct the above conditions you should contact the installing company listed on page 1 of this booklet for service When the security system has accepted a valid code the red ARMED light will illuminate indicating that the system has been turned on If you choose to leave the protected area you must exit through a designated exit door within the exit delay time noted on page 1 If you choose to stay within the protected area insure that all interior zones which may be tripped by your movement are bypassed HOW TO DISARM YOUR SECURITY SYSTEM When you enter the protected area through one of the designated entry exit doors the keypad control will sound a continuous tone beep for the duration of the entry delay time or until you enter a valid code After a valid code has been entered the red ARMED light will turn off and the tone will stop The security system is now DISARMED If a valid code is not entered before the end of the entry delay time an alarm will occur NOTE IF THE RED ARMED LIGHT IS FLASHING DURING THE ENTRY DELAY THE ALARM SYSTEM HAS BEEN ACTIVATED IN YOUR ABSENCE LEAVE THE BUILDING IMMEDIATELY AND CALL YOUR ALARM COMPANY AND OR THE POLICE FROM A SAFE LOCATION HOW TO BYPASS SECURITY SYSTEM ZONES 1 6 When zones are open or unsecured their corresponding LEDs will flash To bypass any of the zones press zone number s to be bypassed and When bypassed corresponding zone LEDs will be on
12. steady Zones cannot be bypassed or unbypassed while the control is in the armed state Upon disarming all bypassed zones will be unbypassed As bypassed zones are not protected the bypass procedure should only be given to authorized persons L TURNING ON THE DOOR CHIME FEATURE Your Security Control Center will operate in the DOOR CHIME mode to allow the monitoring of selected perimeter doors and windows and designated interior areas while the Security System is not armed While in the Door Chime Mode the opening of perimeter doors or windows or a violation of designated interior areas will cause the Keypad control to sound beep for one second To use this feature press the first digit of the Master Code In five seconds the Keypad Control will sound beep indicating that this feature has been enabled To turn this feature off press the first digit of the Master Code In five seconds the Keypad control will sound beep indicating that this feature has been turned off C QUICK ARM FEATURE If checked your security system has a QUICK ARM code programmed This feature will allow you to arm the security system by pressing one pre designated key on the keypad control This QUICK ARM code is for ARMING ONLY and will not disarm the Security System This makes it ideal for a maid code babysitter code etc This code can only be programmed and or changed by your installing company L AUTOMATIC INSTANT ARMING If the
13. to the Panic Hold up input L KEYPAD ACTIVATED AUXILIARY ALARM If checked this feature has been selected by your installing company If so you can activate the auxiliary alarm by pressing the four 4 and six 6 keys at the same time for one second If your system is connected to a monitoring center an emergency report could be sent to that center These keys should only be pressed in an emergency situation requiring response by emergency personnel MANUAL FIRE ALARM If the manual Fire option has been selected by your installing company you can activate the steady siren or pulsing bell by pressing the one 1 and three 3 keys at the same time for one 910 second If your system is connected to a monitoring center an emergency report could be reported to that center These keys should only be pressed in an emergency situation requiring response by fire department personnel L FIRE ZONE If checked your system has zones designated as FIRE zones When this option is selected and approved heat or smoke detectors are attached to these selected zones a Fire alarm sound can be initiated from the security system You should familiarize yourself and your family or staff with this sound see page 1 Fire Alarm sound and follow an evacuation plan if this FIRE alarm sound is heard see page 8 for assistance in formulating an evacuation plan To silence the audible FIRE alarm sound enter a valid code To reset the zone LEDs desi