Home
MANUAL IP67 version
Contents
1. It might be necessary to allow the led unit to cool down for 5 minutes before servicing Do not modify the led fixture in a way not described in this manual StarEye spot IP67 p 6 16 LUX LUMEN Kernenergiestraat 53A 2610 WILRIJK T 32 3 293 35 50 F 32 3 293 35 44 www lux lumen com StarEye spot IP67 3 4 Protection from injury Ensure yourself that the led module and all its accessories are securely fastened Verify that the led unit is firmly fixed to its supporting underground 3 5 Disposing of this product X This led lighting device is manufactured in compliance with directive of the European community waste electrical and electronically equipment Please help to preserve our environment and ensure that this product will be recycled properly at the end of its life p 7 16 LUX LUMEN Kernenergiestraat 53A 2610 WILRIJK T 32 3 293 35 50 F 32 3 293 35 44 www lux lumen com 4 Physical installation Thank you for selecting this StarEye led unit as best solution in your setup Warning Read the safety precautions in this manual before integrating this led unit into your installation Installation must be carried out by qualified professionals only Assure yourself that there is sufficient and unrestricted air flow around the StarEye led unit 4 1 Unpacking The following items are included in your package e Led fixture complete with focussing bracket e Protective antistatic packaging wi
2. sale 3 1 Symbols Following symbols are used to identify important safety information on the product and in this manual AAAAA DANGER Warning Warning Warning Warning Safety Hazardous LED light Burn hazard Refer to user hazard Risk voltage Risk emission Hot surface manual of severe of lethal or Risk of eye Do not touch injury or severe injury death electric shock StarEye spot IP67 p 5 16 LUX LUMEN Kernenergiestraat 53A 2610 WILRIJK T 32 3 293 35 50 F 32 3 293 35 44 www lux lumen com 3 2 Protection from electric shock Although this device itself does not operate with dangerous voltages the installation in which is intended to be used can contain dangerous voltages Shut down the power of the complete installation before carrying out any installation or maintenance work Use only AC to DC power sources suitable for the application and conform to local regulations Please ensure yourself that the AC to DC power supply is able to deliver the rated current requirements of the installation If any cable seal or housing is damaged cracked or reformed disconnect the power of the installation immediately For any additional servicing not described in this manual please contact your point of sale 3 3 Protections from fire and burns Do not operate this led unit if ambient temperatures is above 45 C 113 F Please ensure yourself that sufficient ventilation around the led module is possible
3. MA Return Material Authorization document that you will receive from Lux Lumen Without the RMA document we cannot accept the material The procedure to obtain a RMA Stepi Customer contacts Lux Lumen about warranty defects if material has to be returned Step2 Lux Lumen sends the customer a filled out RMA document using a unique RMA number Step3 Customer sends material include a copy of the RMA document with the material Step 4 Lux Lumen evaluates the problem and informs the client if repair is done under warranty or makes an offer to the client for repair Step 5 The procedure related to lux lumen quality procedures according ISO 9001 is started up StarEye spot IP67 p 15 16 LUX LUMEN Kernenergiestraat 53A 2610 WILRIJK T 32 3 293 35 50 F 32 3 293 35 44 www lux lumen com 10 Used list of abbreviations e AC Alternating current DC Direct current oF Temperature in degrees Fahrenheit C Temperature in degrees Celsius LED Light Emitting Diode StarEye spot IP67 p 16 16 LUX LUMEN Kernenergiestraat 53A 2610 WILRIJK T 32 3 293 35 50 F 32 3 293 35 44 www lux lumen com
4. StarEye led unit 12 volt 350 mA IP 67 version Integrated step down convertor CONTENT PICTURE E 3 1 1 GENERAL zn eener na vereen at te allee ee Ge Ge Gee a Ge Ge aan 3 2 DIMENSIONS eegene ge SNE RE EAR SEET REENEN benee 4 3 SAFETY INFORMATION oseaan ee KR KK KN KR KK KEN KR KK KEN KR RR EER KR KK AA EE EE 5 Sel SYMBOLS ES OE GE EE T wh ER wh Sid DA GR EE nie GED T 5 3 2 PROTECTION FROM ELECTRIC SHOCK ee ees ee ee ee ee ee ee ee ee ee ee ee ee ee ee ee ee ee ee eed dee 6 3 3 PROTECTIONS FROM FIRE AND BURNS ee ees ee ee ee ee ee ee ee eed ee ee ee ee ee ee ee ede ee ee ed ee 6 3 4 PROTECTION FROM INJURY ee ee ee ee ee ee ee ee ede ee ee ee ee ee ee ee ee ee ee ee ee ee ee ee ee ee ee ee ee 7 3 5 DISPOSING OF THIS PRODUCT iese ee ee ee ees ee ee ee ee ee ee ee ede ee ee ee dee ee ee ee ee ee ee ee ee 7 4 PHYSICAL INSTALLATION een ee KKK KR KK REN KR KR REN KE KR EE KERR RR EE ER KK un 8 dd UNPACKING se se Er Re DE BE EES xin EE EN GER nnen ae areca dee EE ieee GE ene 8 4 2 LOCATION AND ORIENTATION ee ee ee ee ee ee ee ee ee ee eed ee ee ee ee ee ee ee ee ee ee ed ee ee ee ee ee ee 8 4 3 MOUNTING Et DEE GE ee eeh 8 5 EXTERNAL CONNECTIONS asse EE KK KN KR KK NNN E KK REN KR KK RN EE KK AA EE 9 5 1 DC POWER AT INPUT NN 9 6 EMC AND SAFETY REOUIREMENTS susse sae ks EER KERR REK REK KREE EN 10 7 INSTALLATION SETUP sees ens KK RN E KK RENE KK RA EE KEER AA EE ER KK AAR 11 SNE ele op el 11 8 SERVICE AND MAIN
5. TENANCE see KR KK KK KR KK KEN KR KK KEN KR KK KEN a 12 8 1 SAFETY PREGAUTIONS SEE Ee DS ee EE Ge EE a 12 eck SEN ien MEE OE EE EE EER adams OOR ER EER 12 9 WARRANTY SS SESSE DROS ER EE eee eee ae ae SE EE AE DEE SG GR EER NEE RR Ewe GE EER 13 9 1 APPLICATION OF WARRANTY ee ee ee ee ee ee ee ee ee ee ee ee ede ee ee ee ee ee ee ee ee ed ee ee ee ee ee ee 13 9 2 RMA PROCEDURE ee ee ee ee ee ee ee ee ee ee ee ee ee dee ee ee ee ee ee ee ee eed ee ee ee ee ee ee ee ee ee ee eke 15 10 USED LIST OF ABBREVIATIONS ees asse KR KK Ra ener en 16 StarEye spot IP67 p 2 16 LUX LUMEN Kernenergiestraat 53A 2610 WILRIJK T 32 3 293 35 50 F 32 3 293 35 44 www lux lumen com Picture 1 1 General StarEye spot IP67 p 3 16 LUX LUMEN Kernenergiestraat 53A 2610 WILRIJK T 32 3 293 35 50 F 32 3 293 35 44 www lux lumen com D Dimensions StarEye spot IP67 p 4 16 LUX LUMEN Kernenergiestraat 53A 2610 WILRIJK T 32 3 293 35 50 F 32 3 293 35 44 www lux lumen com H Safety information Before installing powering up or servicing the IP 67 StarEye led unit it is highly recommended that you read this manual and you ensure yourself that you completely understand its content Observe the safety precautions in this manual Install and operate the led unit only as described in this manual and in conformity with local regulations If you have any questions how to operate this product safely please contact your point of
6. acket is max 55 mm The housing is anodized in black or aluminum silver natural Adapters for track lighting are available The StarEye led unit is polarity sensitive p 11 16 LUX LUMEN Kernenergiestraat 53A 2610 WILRIJK T 32 3 293 35 50 F 32 3 293 35 44 www lux lumen com StarEye spot IP67 Service and maintenance 8 1 Safety precautions Read carefully the safety information in this manual Lock out the power on the entire system and allow all electronic devices to discharge and cool down before executing any service or maintenance 8 2 Cleaning The StarEye led unit itself Extensive dirt and particle build up degrades performance may cause overheating can result in damaged led unit and power supply s Damage by inadequate cleaning or maintenance is not covered by the product warranty Never use solvents to clean the outer housing of the unit Never use water or wet cloth p 12 16 LUX LUMEN Kernenergiestraat 53A 2610 WILRIJK T 32 3 293 35 50 F 32 3 293 35 44 www lux lumen com StarEye spot IP67 Warranty 9 1 Application of warranty Warranty period Warranty service is valid for one year from the date of purchase by the consumer as evidenced by invoice date given out by your point of sale Warranty service Service under warranty can only be done by Lux Lumen Co rdinaties Lux Lumen Kernenergiestraat 53 A 2610 Wilrijk Belgium Any cost of secure transportation of the product t
7. he internal electronics of the StarEye led unit p 9 16 LUX LUMEN Kernenergiestraat 53A 2610 WILRIJK T 32 3 293 35 50 F 32 3 293 35 44 www lux lumen com StarEye spot IP67 EMC and safety requirements The StarEye led unit is fully compliant to the LVD and EMC directive of the European council if used in a properly designed setup EMC requirements of the power supply The StarEye led unit is only intended to be used in lighting applications and as such the complete assembly of led unit and power supply needs to be fully compliant with the harmonized standards Immunity according to e EN 61547 2009 General EMC immunity requirements lighting eq EN 61000 4 1 2006 General immunity testing techniques EN 61000 4 2 2008 ESD immunity test EN 61000 4 3 2006 A1 2007 Radiated immunity test EN 61000 4 4 2004 Fast transients and burst immunity EN 61000 4 5 2005 Surge immunity test EN 61000 4 6 2008 Conducted immunity test EN 61000 4 8 1993 Magnetic field immunity test EN 61000 4 11 2004 Voltage variations immunity test EN 61000 6 1 2005 Generic standards for immunity Emission according to e EN 61000 3 2 2005 A1 2008 A2 2009 Harmonics emission test lt 16A e EN 61000 3 3 2008 Flicker voltage changes limits lt 16A e EN 55015 2006 A2 2009 Conducted radiated emission lighting equipment To achieve this compliance a proper power supply must be supplied In case of doubts contact your poi
8. ns or cleaning carried out by a non Lux Lumen service centre Use of spare parts software or consumables which are not compatible with the product Connecting the product to equipment not intended to be used with this product Defects caused by improper condition of the power supply network Inadequate packaging of the product when returning it under the RMA procedure Accidents or disasters or any cause beyond the control of Lux Lumen including but not limited to lightning water fire public disturbances improper ventilation and acts of god Others It is the responsibility of the customer to backup and save any software files and programs before repair and to restore the same after such repair This warranty does not affect the consumer s statutory rights under applicable national legislation in force nor the consumer s rights against the retailer arising from the sales purchase contract In the absence of applicable national legislation this warranty will be the consumer s sole and exclusive remedy and Lux Lumen cannot be liable for any incidental or consequential damages for breach of any express or implied warranty of this product For full details of the warranty offered on this product please contact Lux Lumen s service center p 14 16 LUX LUMEN Kernenergiestraat 53A 2610 WILRIJK T 32 3 293 35 50 F 32 3 293 35 44 www lux lumen com 9 2 RMA procedure To send material back to Lux Lumen you need a R
9. nt of sale LVD requirements of the power supply The StarEye led unit is only intended to be used in lighting applications and as such the complete assembly of led unit and power supply needs to be fully compliant with following harmonized standards e EN 60598 general requirements of lighting equipment p 10 16 LUX LUMEN Kernenergiestraat 53A 2610 WILRIJK T 32 3 293 35 50 F 32 3 293 35 44 www lux lumen com StarEye spot IP67 Installation setup 7 1 Specification The StarEye led unit is a small and efficient solution for outdoor detail lighting It uses a simple stabilized DC power supply of 12V DC It is possible to use a selection of accessories to manipulate the light output like louvers glare controllers etc e Power consumption max 1 5 watt e Power voltage 12 volt e Current max 120 mA full rated output e Weight 85 gr e Different lenses are possible o FWHM 6 5 o FWHM 15 o FWHM 20 o FWHM 17 x 7 e Different colors are possible o Warm white 2700K CRI 80 Efficacy 80Im watt o Neutral white 4000K CRI 75 Efficacy 100 Im watt o Cold white 6500K CRI 75 Efficacy 130lm watt The ingress protection of the StarEye led unit is IP 67 although the unit is designed to be used in outdoor applications the IP 67 StarEye may be used indoor as well The dimensions of the main led housing is a cylindrical aluminum lathed part of 35mm diameter with length of max 35 mm The height with br
10. o and from Lux Lumen service department will be borne by the customer Limitations Lux Lumen will not warrant the following e Periodic check ups maintenance and repair or replacement of parts due to normal wear and tear e Consumables e Any software e Defects caused by modifications carried out without Lux Lumen s approval e Damage resulting from the fact that a product is not conforming to country specific standards or specifications in another country that the country of purchase Costs incurred by Lux Lumen s service center in making any adoptions or modifications of a product necessary for country specific technical or safety standards or specifications or any other cost to adjust the product as a result of any specifications which have changed since the delivery of the product p 13 16 LUX LUMEN Kernenergiestraat 53A 2610 WILRIJK T 32 3 293 35 50 F 32 3 293 35 44 www lux lumen com StarEye spot IP67 Warranty service is excluded if damage or defects have been caused by Improper use extensive use handling or operation of the product as referred to in the user manual or operator manual and or relevant user documents including without limitation incorrect storage dropping excessive shocks corrosions dirt water or sand damage if the product is not rated to be used in severe conditions indicated by its IP and IK degree mentioned in the product specifications in this manual Repairs modificatio
11. th short form manual label 4 2 Location and orientation This led unit can be used in all directions 4 3 Mounting Surface mounting The StarEye led unit can be mounted on all kind of non combustible materials but take in consideration that the module can have a Tc of approx 30 C higher as ambient temperature In case of problems or doubts please contact your point of sale StarEye spot IP67 p 8 16 LUX LUMEN Kernenergiestraat 53A 2610 WILRIJK T 32 3 293 35 50 F 32 3 293 35 44 www lux lumen com AN A AN AN StarEye spot IP67 External connections 5 1 DC power at input Safety precautions Never connect the live power on the input terminals of the StarEye led unit In case of doubts contact your point of sale Polarity The StarEye led unit is polarity sensitive So observe polarity and cabling e Inner conductor marked with 1 positive e Inner conductor marked with 2 negative Improper connection might damage the StarEye led unit and power supply permanently In case of inversed polarity the warranty is void Power supply Rated voltage The rated input voltage range of the Star eye led spot is 12V DC Due to the use of a step down convertor integrated in the housing a highly efficient system is created Cable Please ensure yourself that the cable end is watertight sealed at the connection If this is not properly done water can pass through the inner conductors of the cable and damage t
Download Pdf Manuals
Related Search
Related Contents
CAROL MODIF GB-ES-IT-PT-G2.qxp:a.qxp 12. Troubleshooting 使用のしおり - ジャノメミシン épreuve écrite d`admissibilité AGROEQUIPEMENTS N°2 GC Fuji IX GP GB E GC Fuji IX GP Acute MS-Tech CA-0145 computer case META SCRIPTS Table of Contents Copyright © All rights reserved.
Failed to retrieve file