Home
"user manual"
Contents
1. 3mm will be lost due to the hand switch Start up Initial display communication Under normal condition the display automa tically went to display layout as right in 2 to 5 sec If the system feel a incomplete homing the homing icon well be visible Press the down symbol for homing Connect your Joggle Connect the Bus cable to the hand switch If appropriate connect two bus cables to the hand switch Reset If some components are changed columns motor control for motors etc there will be need for a forced reset Please follow the instruction below Forced Reset If the reset symbol will be visible please press 2 bottoms min 7 sec the reset symbol will show up r 43 j Then press and hold down symbol until the columns have gone to lowest level Wheel icons How to understand the symbols N Adjust the table upwards Scroll in the menu e Adjust the table to sitting position 5 Scroll to left in the menu O Menu press for the menu s Enter confirm your selection hd Adjust the table downwards Scroll in the menu Adjust the table to standing position TT Scroll to right in the menu 6 Quick start Run Drive the table to the position you will store sitting or standing Two different processes Press the menu button and hold for more than 2 sec Press sitting Press standing left side right side memory 1 m
2. G Active l ytyy hinnastostamme p yt kansi ja runko eriteltyn T m tarkoittaa yhdistelyn valinnanvapautta kansien ja runkojen osalta huomioiden kuitenkin tekniset rakennerajoitteet e P yt kannet viistetyill reunoilla F kannet ydin 22 mm paksua MDF levya pinta viilutettu 0 6 mm py kki tai Koivua viistetyill reunoilla e P yt kannet suorilla reunoilla S kannet ydin 22 mm paksua lastulevy pinta viilutettu 0 6 mm py kki tai koivua suorilla reunoilla Matalapainelaminaattiset kansien MB MR ME MV M6 och M8 ydin 22 mm paksua lastulevy suorilla reunoilla e Muut lis varusteet p yt sein kkeet litte n n yt n teline johtokouru CPU teline ja s hk liit nn t e Takuu 5 vuotta rakenne materiaali ja valmistusvirheille e Testattu EN 527 1 EN 527 2 EN 527 3 ISO 21016 mukaisesti korkeudens d n kest vyys P yt on CE hyv ksytty ja t ytt standardin AFS 2008 3 ja AFS 2009 5 European directive 2006 42 EG TEKNISET TIEDOT e Virtal hde Sama aggregaatti 110 240 V e Nopeus kansi max 30 kg 40 mm s e Nopeus 70 kg 33 mm s e Maksimilastaus 120 kg sis kannen e Ylikuumenemissuoja 1 min k ytt 9 min tauko e nitaso mittaus tehty p yt kannella 1600x800 mm noin 17 kg 40 dB 40 45 dB ulosvedett v ll kannella e Standby k ytt 0 45 W e MAX kulutus vain kansi kansi 17 kg 150 W e MAX kulutus lastaus 120 kg sis kannen 320 W e Kytkett vien jalk
3. Istuma seisomap yd t EFG Active EFG012682 EFG Active EFG Active on seuraavan sukupolven istuma seisomap yt Hiljainen s hk s t inen korkeudens t joka soveltuu hyvin avotoimistoon P yt n voidaan yhdist uusi IT tekniikka esim yhteisk yt ss olevien ty p ytien varaussysteemi European Furniture Group Istuma seisomap yd t EFG Active Tuotetiedot e S hk s t inen metallirunko nelikulmaiset T jalat paksuin osa yl sp in sijoitettuna Maalattu struktuurimusta 24 RAL 9005 struktuuriharmaa 26 RAL 9007 hopea 62 RAL 9006 valkoinen Z4 RAL 9016 tai kromattu 90 e Rungossa on kaksi moottoria sijoitettuna p yd n jalkoihin Irrallista hallintayksikk ei tarvita e S t v li 500 mm LO tai 650 mm HI e Saatavissa 2 tai kolmijalkaisena mutta voidaan tarvittaessa kytke jopa 8 jalkaa yhteen systeemiin kytkett ess useampi kuin 3 jalkaa tarvitaan useampi muuntaja lis virran saamikseksi e Rungossa on teleskooppinen leveyss t v lill 1100 1950 mm ja se sopii 1200 2200 mm leveisiin kansiin e Lis varusteet ohjelmoitava ohjainyksikk n yt ll joka esimerkiksi n ytt istuma ja seisomakorkeuden t rm yssuojamekanismi runko pys htyy automaattsesti t rm yksen sattuessa ja ulosvedett v p yt kansi p yt sein kkeell ja ilman Huom Ulosvedett v kansi voidaan yhdist ainoastaan 2 jalkaiseen runkoon ja suorakulmaiseen kanteen ACTA20 e EF
4. emory 2 5 T Go to memory 1 Go to memory 2 Press and hold 10 How to go to memory Press the menu button less than 2 sec O Use arrow up and down to navigate to memory setting Hold Menu button to go to the stored position O Lower limit Set the lower limit if there are device eguipme ntwich could create a risk of pinching or risk for table damages Press menu button stand icon 4 time to come to set memory menu i gt Il Press Menu Enter to confirm O Adjust the figures to the chosen level with the arrows up or down a Ga a Aj Press Menu Enter and the value are stored Please notice that the figures count from the table top surface calibrated level 15 How to set memory Run Drive the table to the position you will store sitting or standing This device have 5 memories position memories Press menu button stand icon 1 time to come to set memory menu 6 i Use arrow up and down to navigate to set memory setting P P Press Menu Enter and the value are stored Q The display confirm by flashing 3 times and then returns to normal mode Units Choose between metric or Imperial system Press menu button stand icon 5 time to come to set memory menu i N hi LI Press Menu Enter to confirm Adjust the settings with the arrows up or D Fm Imperial inches Metr
5. ics centimeters A a CM Press Menu Enter and the setting are stored O 16 Calibrate Measure the distance between the floor and the top of the table sheet Press menu button stand icon 2 times to come to calibrate menu 6 i Press Menu Enter to confirm Q Adjust the figures to the selected value with the arrows up or down P PI m Press Menu Enter and the value are stored 13 Reset away Press menu button stand icon 6 time to come to set memory menu i a KITA Press Menu Enter to confirm O N Li Press down and hold until the columns have gone to the lowest position Do reset if any parts have been changed of if you discover interference between the columns 17 Upper limit Set the upper limit if there are limited space in height Press menu button stand icon 3 time to come to set memory menu i Press Menu Enter to confirm Q Adjust the figures to the chosen level with the arrows up or down Press Menu Enter and the value are stored Please notice that the figures count from the table top surface 14 Error codes E lt 1 Hard stop 2 Back off 3 Soft stop 4 Waiting for button 5 Waiting for button release 6 Motor lost O Overheating Thermometer flashing wait 10 minutes for motor cooling 18
6. ojen lukum r maksimissaan 8 kpl vaatii lisavirranlahteen e Minimi maksimikorkeus s t v li 500 mm nelikulmaiset jalat paksuin osa yl sp in sis jalan kannen 22 mm 680 1180 mm e Minimi maksimikorkeus s t v li 650 mm nelikulmaiset jalat paksuin osa yl sp in sis jalan kannen 22 mm 640 1290 mm e Kuljetusl mp tila varasto 40 65 C e K ytt ymp rist n l mp tila 15 35 C EFG Toimistokalusteet Oy www efg fi Istuma seisomap yd t EFG Active EFG012680 EFG012498 Ty piste EFG Active EFG Storage s ilytintorni EFG ONE ty tuoli ja EFG Tab p yt sein ke EFG012636 Ty piste EFG Active EFG ONE ty tuoli ja EFG Tab p yt sein ke EFG Active portaattomasti s dett v t pitkitt istuet ulkomitta tukien v lill 160 mm EFG Toimistokalusteet Oy www efg fi USER MANUAL JOGGLE Programmable hand control with display optiona Display layout Explanation of the symbols ON Tool ue Imperial inches M ERON 5 Thermometer E Error codes n Reset GCM Metric centimeter 15 sec sleep mode Display backlight will go to sleep mode after 15 sec of inactivity Mount your Joggle Use the 2 attached screws for fixing to the ta ble top If the thickness of the table top is less than 18 mm please use shorter screws In situation of sloped edges of the table top there could be need for a third fixing point When screw will be chosen consider that 1
Download Pdf Manuals
Related Search
Related Contents
Manual Instrucciones NETTUNO Sept 2012 ペダルキーロック 取扱説明書 Arctic-Temp® 表面性状測定用非接触検出器 CrispyPU 取扱説明書等(1) - アイ・オー・データ機器 Netatmo Instalacion Termostato modo 2 Schumacher SE-3522 Automobile Battery Charger User Manual Copyright © All rights reserved.
Failed to retrieve file