Home

Setting code User Manual - Embedded Barcode Imager

image

Contents

1. urn off urn on Define Fixed Length Disable Fixed Length Enable Fixed Length Define Fixed Length Range To enable read Interleaved 2 OF 5 code at fixed length or in between a length range Data code and Save code should be used in the setting Please note there are maximum 32 fixed lengths even in between 2 and 64 can be selected Every length is valued by 3 decimals Please see the following examples Example 1 set to read Interleaved 2 OF 5 code at fixed length 18 Firstly to read the barcode Define Fixed Length range as bellow Then to read Hex Number for 0 1 8 and Save code Example 2 set to read Interleaved 2 OF 5 code in between length of 12 and 24 Firstly to read the barcode Define Fixed Length range as bellow Then to read Hex Number for O 1 2 0 2 4 and read Save code to complete Please note that the start should be less than the end Cancel Defined Fixed Length range to shield a fixed length or a length rage under the status of fixed length reading The setting process is just the same as above process Define BIN range Cancel sal UM range Page 34 of 65 T T urn off urn on ITF Setup Set All Default Decode ITF14 but don t transmit check
2. T T urn off urn on 9 1 Macro Model Transmit right after scan Mode Transmit according to code sequence small number will transmit first system will automatically accumulate information to want previous number The memory buffer is 64kbyte Mode Read all bar codes in memory buffer and then send out at once The maximum buffer is 64kbyte Model Mode2 Mode3 Ex Delete the Data of Macro Buffer Page 42 of 65 Turn on 9 2 PDF417 Set All Default In order to reduce the chances of a misread the best way is to predefine data length in Ar Hl Disable Enable Message Length advance Please read below bar code Setup to define both minimum length and maximum length according to your requirements And pay attention to the following notes 1 Both minimum and maximum lengths must not be zero 2 Minimum length should be smaller than maximum length 3 If both minimum length and maximum lengths are the same read one length only 4 The maximum length for any 2D bar code should be not more than 65535 5 Save is required after reading the code above e g Decode only those bar codes with 8 to 12 characters Min Length 8 Max Length 12 Step 1 Find the bar code type Step 2 scan Min Length Step
3. 1D Bar Codes read the one or two codes the same type 3 5 User defined setting code Default setting codes perform fundamental functions such as enable and disable User defined setting codes integrate numerous fundamental functions It makes complex and repetitive setting to be one setting code Batch setting code It can set numerous parameters setting codes and save them to user default The enable batch setting code mode should be read before reading of batch setting code Making User defined setting code refers to Chapter 11 Set product ESN number make a User defined setting code containing product ESN number Use the ESN setting code by reading the enable product ESN setting Enable batch setting code mode Enable product ESN setting Page 5 of 65 T Turn off urn on 3 6 Message of setting code to send Setup Don t Transmit Setting Code Transmit Setting Code 3 7 Message of system to send Setup Send message related to system Don t display when power on Display when power on Page 6 of 65 T T urn off urn on Chapter 4 Communication 4 1 Communication type selections Note Device must have certain module to support the communication modes USB Da
4. T Turn off urn on 4 4 BlueTooth Selections Note BlueTooth parameter setting is only available for devices with BlueTooth interface namely HR200 Reset Set device name Max 16 characters Disable password verify Enable password verify Password setting Max 6 characters Page 14 of 65 Turn off Chapter 5 Hardware selections 5 1 Light Mode selections LED Flash When Scan LED On When Scan 5 2 Aiming Mode selections LED Flash When Scan Sense mode 5 3 Decoding Voice selections Off Page 15 of 65 Turn on LED Always On LED Always Off LED Always On LED Always Off ON T T urn off urn on Chapter 6 Data Format 6 1 All prefix and suffix selections Order of data format CodelD prefix AIM suffix self prefix data message self suffix terminator Disable set not to add prefix and suffix to all decoding message Enable set to add prefix and suffix to all decoding message Disable All Prefix and Suffix ER Enable All Prefix and Suffix 6 2 Prefix order selections D
5. Transmit Check Digit 2 Digit Addenda ON 5 Digit Addenda ON Turn off Don t Transmit First 0 Don t Extend To UPC A Page 31 of 65 Turn on Transmit First 0 Extend To UPC A T Turn off urn on 8 5 UPC A Set All Default UI UI Disable Enable Uu Ui Don t Transmit Check Digit Transmit Check Digit UI Uu 2 Digit Addenda OFF 2 Digit Addenda ON MU HI 5 Digit Addenda OFF 5 Digit Addenda ON UI UI Don t Transmit First Transmit First O Page 32 of 65 Turn off Turn on 8 6 INTERLEAVED 2 OF 5 Set All Default Disable Enable Min Length 4 Max Length 80 No Check Digit Validate Check Digit But Don t Transmit Validate Check Digit and Transmit Page 33 of 65 T T
6. Blue2D package Normal Package STX ATTR LEN AL_TYPE DATA LRC 0x02 0x00 datalength 0x36 data checkout Page 20 of 65 LRC OxFF STX ATTR LEN AL_TYPE DATA s all characters running XOR operation T Turn off urn on ESC_Bank Package STX DATA ETX BCC 0x02 data 0x03 checkout BCC DATA ETX s all characters running XOR operation Blue2D Package CODE ID LEN DATA CODE TYPE data length data description of barcode type Note Something inside is optional Page 21 of 65 T urn off T urn on 6 10 Intercept message selections Disable set not to intercept decoding message Enable set to intercept decoding message Setup to Intercept Message 1t must be used with the combination of digit code and storage code Attention for 1D barcode it is at most to intercept 5 segment of data message while for 2D barcode 3 segment of data message Method to Setup 1D barcode first to check up the list of type order in order to get the type sequence number of barcode to set for device to read the code of Setup to Intercept Message in below then to read three places of decimal system related to type sequence number And the direction to intercept each segment in turn O means to count forwards and the rest to count backwards
7. e e a fo mu pe fa fofo fm e fa fofo mma e e efe om e a a fa masam a a fa oms e a efe com Pio fofo a Tera LA EE E Lae O E Page 55 of 65 Chapter 14 Keyboard Country U S default Belgium Brazil Canada French Czechoslovakia Denmark Finland Sweden France Germany Austria Greece Hungary Israel Hebrew Italy Latin American Netherlands Dutch ss Cg aa lo a sa poa er En cacon EE Page 56 of 65 Chapter 15 A contrast list of barcode and serial number me EE cm mer EE Ke e UPC A DataMatrix Chinese Interleaved 2 OF 5 Information Code China Post25 SPEC OCR B Page 57 of 65 Chapter 16 Configuration Commande list 16 1 Hex Numbers and Overall Setup Comman 0000000 0000010 Hex Number 00 0000110 0000120 140 150 160 170 180 190 0001000 0001010 0001020 0001030 0001040 0001050 0001060 0001070 0001080 0001090 0001110 0001130 0001150 0001160 Resume user defined default setting 0001090 D barcode read pel code only son System 0003000 Send System Message E Message Setting code 0006000 Off Default Selection 0006010 On Message of system 0007000 to send Setup 0007010 l 8 Definition o N OO T SIS A C E F Save The Setting Cancel One Data Of Current Setting Cancel One String Of Current Setting Cancel Current Setting Set All Default Set All Bar Codes Disable Set All Bar Codes Enable Set A
8. CODE 52 11 1 HOWTO BUILD A BATCH COMMAND eee 52 112 PRODUCE SETTING CODE masama nd sa akal anal asuh enakan 53 113 USE BATCH SETTING CODE BN BN 53 CHAPTER 12 ASCH TABLE ee 54 CHAPTER 13 A CONTRAST LIST OF DEFAULT FOR CODEID AND AIM 55 CHAPTER 14 KEYBOARD COUNTRY EEN 56 CHAPTER 15 A CONTRAST LIST OF BARCODE AND SERIAL NUMBER 57 CHAPTER 16 CONFIGURATION COMMANDS LIST EE 58 16 1 HEX NUMBERS AND OVERALL SETUP ie ee ee ee ee ee ee ee 58 16 2 COMMUNICATION Nia a O a 59 16 3 HARDWARE SETUP ds ad eos co eo ON 60 AI NA e BN 60 16 5 DECODING MODE e e GE KAPG ro eo e ad ee ala oi 166 IDSYMBOLOGIESSETUP es 62 167 2DSYMBOLOGIES SETUP ee EE 64 1G 8 SOCR A nan Bangaan na AB am aa 65 Ifto make use of setting code the reading device must startup the function of setting code at first that is T T urn off urn on Chapter 1 Setting code turn on off to read the startup code turn on first on the top Read the close code turn off after the setting that is to turn off the function of setting Attention when the function of setting code is under the state of startup the reading device will automatically turn off the function of setting code if it read the non setting code Chapter 2 Setting code step by step demo Demo 1 Enable PDF417 by setting code EN HEEN Turn on setting code Enable PDF417 Turn off setting code
9. digit Decode ITF14 and transmit check digit Don t decode ITF6 Decode ITF6 but don t transmit check digit Decode ITF6 and transmit check digit Page 35 of 65 Turn off 8 7 China Post25 Disable Min Length 4 Validate Check Digit But Don t Transmit Set All Default No Check Digit Turn on Enable Max Length 80 Validate Check Digit and Transmit Turn off 8 8 CODE 39 Disable UI Min Length 1 Set All Default Page 37 of 65 Turn on Enable Max Length 48 T T urn off urn on Don t Transmit Start Stop Characters Transmit Start Stop Characters No Check Character Validate Check Character But Don t Transmit Validate Check Character and Transmit Disable Full ASCII 39 Enable Full ASCH 39 Page 38 of 65 Turn off 8 9 CODABAR Set All Default Disable Mi
10. double quotation marks If the setting information is viewable character then this mode of setting is appropriate e g The command setting the user defined prefix information as AUTO ID 0300000 AUTO ID Page 52 of 65 T T urn off urn on 11 2 Produce setting code Make the command list ended with save command to a PDF417 QR code or DataMatrix For example to produce a batch command means light Always On Auto Scan change delay time to 2 seconds Disable Fixed Length of 12 of 5 Firstly find commands as follows 0200030 light Always On 0302010 Auto Scan 0313000 2000 change delay time to 2 seconds 0405140 Disable Fixed Length of I 2 of 5 0000160 Save The batch setting code PDF417 is as follow 11 3 Use batch setting code Read Turn on setting code then read enable batch setting code and then read the batch setting code produced in chapter 11 2 Read Turn off setting code WM Il Turn on setting code Enable batch setting code it Hi Se pon Batch setting code Turn off setting code Page 53 of 65 Chapter 12 ASCII TABLE SC WE q o 5D 38 X 78 39 Y 79 3A Z 7A 3B 1B sI y gt se 2 se Page 54 of 65 Chapter 13 A contrast list of default for CodeID and AIM com 5 a efa EEN a efa wm a a efe ewe O a a efe memso
11. ee ee ge ene 15 CHAPTER 6 DATA FORMAT uses sesse sesse sesse se se ee ee Se ee Be ee Be EE BE EE Be EER Gee esa eae Be ee Be EE Be EE Be Bees sos 16 6 1 ALL PREFIX AND SUFFIX SELECTIONS ul ees esse ses se ee seek seek ek ee ee se ges ee see ee gegee ee see ene 16 6 2 PREFIX ORDER SELECTIONS ee se ee sek ek ee se se ge ee se se eek ek ee ee se es ee Gee ee ke Ge Ge es 16 6 3 SELE PREFIX SELECTIONS ti ee Se Es Eg ei Ge ge ee ES qc 17 6 4 SELF SUPFIX SELECTIONS nn BRA rito pa ea eege deed 17 6 5 6 6 6 7 6 8 6 9 6 10 INTERCEPT MESSAGE SELECTIONS ENNEN 22 6 11 TERMINATOR SELECTIONS ua 23 CHAPTER 7 DECODING MODE SELECT IONS ccssssssssssssssssessssssssssessessssessssesessesessceees oe 24 7 1 READING MODE SELECTIONS eee 24 T2 CMOS SENSIBILITY SELECTIONS LX aman 24 73 DELAY TIME SELECTIONS 74 VIBRATION MOTOR CONTROL PARAMETERS SELECTIONS CHAPTERS 1D SYMBOLOGIES SETUP oeooooooooooooooooooooooooooi 26 8 1 82 83 84 8 5 8 6 8 7 8 8 g9 CODABAR EEN 39 O De AN NIA 40 SAT UCCEAN 128 SETTING se GE OG GING GE ERG AG GE 40 CHAPTER9 2D SYMBOLOGIES SETUP EE a1 HD MAGRO EE EG EE EE 42 GO e DEE EE EE a a ED GE a 43 O EEN 44 GE DE EE 46 dy DATAMAT EG n a do na alun una an DOG 96 CHINESE INFORMATION CODE ooo 97 USER DEFINED 2D BARCODE SETTING CHAPTER 10 OCR SETUP EEN 51 OM SPRCSOCROB e thea tt Rate pait ate nam tata e ai CHAPTER 11 HOW TO PRODUCE A BATCH COMMAND
12. intercept message Page 22 of 65 T T urn off urn on 6 11 Terminator selections Disable decode with out terminator suffix Enable decode include terminator suffix Set terminator suffix should work with the code of Hex Number and Save Maximum terminator suffix length is 2 characters The process is check hex digits in the ASCII table Read User Define code as follows Then read hex digits in order Lastly read save code to complete the process For example set terminator suffix to be CR LF ASCII hex digit are OD and OA Read the User Define code as follow And then read hex digits O D O and A read save code to complete the process Note please setup the terminator suffix after data digits are edited and packed Disable Enable User Define Page 23 of 65 T T urn off urn on Chapter 7 Decoding Mode selections 7 1 Reading mode selections Types of reading modes Trigger Auto Scan and Continue Scan Trigger trigger to read The system is off when reading completed or no trigger Auto Scan system goes on non stop reading Continue Scan First trigger enable reading The system turns off at the next trigger Trigger Auto Scan Co
13. parallel QR codes vertical or horizontal Double QR code setting includes read single QR code only read Double QR codes only and read both types Read single QR code only device read only one row of QR code at a time Read Double QR codes only On a map device must be detected two QR code and decoding success then sent decoding information Both types On a map when device detected Double QR codes and decoding success then sent decoding information or else Read single QR code Read single QR code only oe Read Double QR codes only Both types Page 45 of 65 Turn off T urn on 9 4 Aztec Set All Default Disable Enable Message Length In order to reduce the chances of a misread the best way is to predefine data length in advance Please read below bar code Setup to define both minimum length and maximum length according to your requirements And pay attention to the following notes 11 Both minimum and maximum lengths must not be zero 12 Minimum length should be smaller than maximum length 13 If both minimum length and maximum lengths are the same read one length only 14 The maximum length for any 2D bar code should be not more than 65535 15 Save is required after reading the code above e g Decode only those bar c
14. the same read one length only 24 The maximum length for any 2D bar code should be not more than 65535 25 Save is required after reading the code above e g Decode only those bar codes with 8 to 12 characters Min Length 8 Max Length 12 Step 1 Find the bar code type Step 2 scan Min Length Step 3 scan 8 see Appendix A Step 4 scan Save Step 5 san Max Length Step 6 scan 1 2 and Save Min Length Max Length 7827 Page 49 of 65 IT only works on EM2100 EM2200 EM3000 EM2027 HR200 User defined Imaging f Turn ofi 9 7 User defined 2D barcode setting T urn on software and OMG should be integrated to use the setting The default configuration is ULI Set all default user defined Disable Enable Page 50 of 65 Turn off Turn on Chapter 10 OCR Setup 10 1 SPEC OCR B Set All Default Disable Enable This OCR B reading only support 9 OCR B digital characters which is provided by IMG and with prefix Page 51 of 65 T urn off T urn on Chapter 11 How to produce a batch command code Users can do batch command setup on devices 11 1 How to bui
15. 1103031__ Unknown Charaeters Beepon J 1103041 Convert All to UpperCase ____ 1103042 ConvertAlltoLowerCase______ ___ 1103051 USB Keystroke Delayfor20ms 1103052 USB Keystroke Delayfor40ms LL 1103061 Enable Keypad Emulation 1103120 Numeric Keypadon 1103140 CwirAsciIModeon_______ 0 1105000 Reset N BlueTooth t105020 Turn off password verify J Page 59 of 65 16 3 Hardware Setup 02000003 LED Flash When Scan D Light Selection 02000101 LED Always On 02000200 LED Always Off 02000301 LED On When Scan 0201000 LED Flash When Scan 0201010 LED Always On Aiming Selection 0201020 LED Always Off 0203000 Jor Decoding Voice Up to 16 Selection 0203010 ON characters 16 4 Data Format All Prefix Or 0311000 Disable All Prefix And Suffix Sure Enable 0311010 Enable All Prefix And Suffix bo ff Selection 0317000 CodeID AIM Self Prefix 0317010 CodelD Self Prefix AIM Pd 0317020 AIM CodelD Self Prefix ES prefix order 0317030 ATM Self Prefix CodelD oO 0317040 Self Prefix CodeID AIM 0317050 Self Prefix AIM CodeID 0305000 Disable Self Prefix Self Prefix 0305010 Enable Self Prefix Selection 0300000 0306000 Self Suffix 0306010 Set Message Of Self Prefix Disable Self Suffix Enable Self Suffix Selection 0301000 0308000 Set Message Of Self Suffix Don t Add AIM Prefix To Decoding Result Add 1 AIM Prefix Character To Decoding Resul
16. 27 REDE oe 0510020 Enaple e o Default Value Is 1 Default Value Is 2710 Default Set The Min Message Length Value Set The Max Message Length Value Set QR All Default Disable nable Set The Min Message Length Value et The Max Message Length Value Read single OR code onl Read Double QR codes onl Both types Set Aztec All Default Disable Enable Set The Min Message Length Value Set The Max Message Length Value Set DataMatrix All Default Disable Enable Set The Min Message Length Value Set The Max Message Length Value Read single DataMatrix onl Read Double DataMatrixs onl Both types Set Chinese Information Code All Default Disable Enable kel efault Default Value Is 1 Default Value Is 7089 efault Lo Default Default Default Value Is 1 Default Value Is3832 Default Default Default Value Is 1 Default Value Is 3116 Default 5 efault Chinese Information Code Page 64 of 65 16 8 OCR Setup 0600000 Set SPEC OCR B All Default Default qa SiC Page 65 of 65 A of Client Service E Phone 0086 591 83979219 FAX 0086 591 83979208 E mail cs mail nlscan com Address No 1 Rujiang Avenue Mawei District Fuzhou Fujian Mainland China Newland Science amp Technology Park os Code 350015
17. 3 scan 8 see Appendix A Step 4 scan Save Step 5 san Max Length Step 6 scan 1 2 and Save Min Length Max Length 2710 Page 43 of 65 Turn on 9 3 QR Code Set All Default In order to reduce the chances of a misread the best way is to predefine data length in advance Please read below bar code Setup to define both minimum length and maximum length Disable Enable Message Length according to your requirements And pay attention to the following notes 6 Both minimum and maximum lengths must not be zero 7 Minimum length should be smaller than maximum length 8 Ifboth minimum length and maximum lengths are the same read one length only 9 The maximum length for any 2D bar code should be not more than 65535 10 Save is required after reading the code above e g Decode only those bar codes with 8 to 12 characters Min Length 8 Max Length 12 Step 1 Find the bar code type Step 2 scan Min Length Step 3 scan 8 see Appendix A Step 4 scan Save Step 5 san Max Length Step 6 scan 1 2 and Save Min Length Max Length 7098 Page 44 of 65 T T urn off urn on Double QR code setting Double QR code 2
18. 3 bit number of decimal system for startup and terminal at last to read storage code able to complete its setting Attention the upper limit value for startup and terminal position of 1D barcode is 127 2D barcode basically it is the same to the 1D barcode except that its startup and terminal expressed with 6 bit decimal system respectively for example the startup position is a number of XXXX its transform of 6 bit decimal system number is OXXOXX Be aware the upper limit value for both of startup and terminal position of 2D barcode is 9999 Example 1 the method to get digit at no 1 to no 3 places and the last 4 places only to set EAN 13 1 read the code of Setup to Intercept Message 2 check up the list of type sequence number get the sequence number of EAN 13 is 005 3 read data code of the number below in turn 00 5 00 0 001 003 001 00 4 001 Sequence Count Nol No 3 Count No 4 Nol number of type forwards backwards 4 read save code to complete setting Example 2 the method to get digit from no 1 to no 20 places and from no 113 to no 140 places only to set OR 1 read the code of Setup to Intercept Message 2 check up the list of type sequence number get the sequence number of OR is 033 3 read data code of the number below in turn 033 000 000 001 000 020 000 QOL OU QOL 040 Order of type Direction No 1 No 20 Direction No 113 No 140 4 read save code to complete setting Disable KK Enable Method to set
19. 7 data bits 8 data bits Page 9 of 65 NOTE HID KBW selection is only available for EM1030 EM2027 and HR200 Keyboard country Usidetauy Lu Norway 1s Finland Sweden Lo Low Li Germany Austria ls Sweden Io Greece H SwiteerlandGermam 24 Netherlands Dutch o II T Turn off urn on 4 3 HID KBW selections Caps Lock When enabled the digital scanner inverts upper and lower case characters on the bar code as if the Caps Lock state is enabled on the keyboard This inversion is done regardless of the current state of the keyboard s Caps Lock state O O Hook ff n Page 10 of 65 Unknown characters are characters the host does not recognize When Unknown Characters Beep T T urn off urn on Unknown Characters Beep OFF is selected no error beeps sound When Unknown Characters Beep ON is selected if bar codes contain unknown characters an error beep will sound Off O n Emulate Keypad When enabled all characters are sent as ASCII sequences over the numeric keypad For example ASCII A would be sent as ALT make 0 6 5 ALT Break Disable Enable Convert Case When enabled the digital scanner converts all bar
20. Check Digit and Transmit dl 0408080 Dont Transmit Start Stop Characters LO 0408110 Set FULLASCIB9 Enable dl 0409000 Set Codabar All Default 0409010 Disable A Codabar Set The Min Message Length Value 0409080 Dont Transmit Start Stop Characters o ooo 0410010 Disable JC Code93 Set The Min Message Length Value 0412000 Set UCC EAN 128 All Default UCC EAN 128 0412010 Disable PT 0412020 Page 63 of 65 16 7 2D Symbologies Setup Command N 0500000 Delete The Data Of Buffer Mode 1 Transmit The Block s Data 1 0300010 Directly After Reading Mode 2 Transmit The Data Base On Reading Order The Saving Data Can t Be Larger Than 64k Byte viz When The 0500020 Blocks Whose Connection Numbers Are Macro Less Than The Current Block s The Data Which Has Been Connected Will Be Transmitted Including The Current Mode 3 Connect After Reading All Data Blocks If The Data Is Larger than 64k 0500030 Byte The Data Would Be Transmitted By O Mode 2 0501000 Set PDF417 All Default Default 0501010 Disable PDF417 0501020 0501030 0501040 0502000 0502010 0502020 QR Code 0502030 0502040 0502070 0502080 0502090 0503000 0503010 Aztec 0503020 0503030 0503040 0504000 0504010 0504020 DataMatrix 0504030 0504040 0504070 0504080 0504090 0508000 0508010 0508020 0508030 Set The Min Message Length Value Default Value Is 1 0508040 Set The Max Message Length Value Default Value Is 78
21. Demo 2 Setup reading sensitivity to be 10 D Wi Wu 1 Turn on setting code set sensitivity to be 10 eg WU A Wii 0 Save Turn off setting code Page 1 of 65 Turn off Chapter 3 Overall Setup 3 1 Save and cancel Save Abort One String of Current Setting 3 2 Hex Numbers 0 2 4 6 Page 2 of 65 Turn on Abort One Data of Current Setting Abort Current Setting 1 3 5 H Turn off 8 A C E Page 3 of 65 Turn on 9 B D F T Turn off urn on 3 3 Overall selections Set All Default IO II Save to user default load user default Ji LL Disable All Bar Codes Enable All Bar Codes III II Disable All 1D Bar Codes Enable All 1D Bar Codes LU LU Disable All 2D Bar Codes Enable All 2D Bar Codes Page 4 of 65 Turn off Turn on 3 4 Double 1D selections 1D Bar Codes only read one code 1D Bar Codes only read two codes the same type
22. ID Refer to Appendix B for ASCII table fine the ID you wanted then go to Appendix A for Hex table For example to set J as code ID for Code 128 Scan CODE 128 first find J at ASCII table position 6A then go to Hex table to scan 6 A and Save There is only one byte for each Code ID CODE128 UCC EAN 128 EAN 8 UPC E Interleaved 2 OF 5 Code39 Page Code93 19 of 65 EAN 13 UPC A China Post25 CODABAR CodelD setting for 2D barcode should work with the code of Hex Number and Save One CodelD can set one digito The setting process is check ASCII table for hex data and read the T T urn off urn on 6 8 Define 2D Code ID relevant setting code as follows then read data code accord with hex data lastly read save code to complete the process For example set PDF417 CodelD to be r ASCII hex value for r is 72 The code PDF417 as follows should be read and then read data code 7 and 2 Read save code to complete the process PDF417 Aztec 6 9 Data Packaged selections Unpackaged ESC_Bank package QR Code DataMatrix Normal Packaged
23. Powered By DIMG 7 IMG setting code User Manual Version 2 02 007 Newland Newland North America Inc Tel 510 490 3888 Fax 510 490 3887 http www newlandna com Contents CHAPTER 1 SETTING CODE TURN ON OFF oooocoococoooooooooooooooo 1 CHAPTER 2 SETTING CODE STEP BY STEP DEMO eeecocoooooooo 1 CHAPTER 3 OVERALL SETUP csssssssssssssssssesssscssssossssessssessssessssesssscseesessssessesessesesensessssesessee Ses 2 3 1 SAVE AND CANEEL eege se be eg Re Re Ke ee ee Gene EA geht 2 3 2 HEX NUMBERS 2 3 3 OVERALL SELECTIONS sensasi SN Sedan 4 34 DOUBIE IDSELECTIONS ii rn 5 3 5 USER DEFINED SETTING CODE e a ese se E EE ek ee se see EEE EA ees 5 3 6 MESSAGE OF SETTING CODE TO SEND SETUP ne 6 3 7 MESSAGE OF SYSTEM TO SEND SETUP a 6 CHAPTER 4 COMMUNICATION eeeuse sesse sesse sesse see ee see Be ee Be ee Be ee Be EE senado Be Bee EE sense Be ee Be EE Be GE semente sus 7 4 1 COMMUNICATION TYPE SELECTIONS eee 7 4 2 RS232 SELECTIONS deierste es de de EE Ee ms ee eege dais 8 4 3 HID KBW SELECTION Sisi Bun mada 10 44 BLUETOOTH SELECTIONS ul ANEN 14 CHAPTER 5 HARDWARE SELECTIONS uses sesse sesse se see se see ee see be ee se ee be ee se ee be ee Se sense see se see se se see 15 5 1 LIGHT MODE SELEC FONS a n Miah ee il ea ais 15 5 2 AIMING MODE SELECTIONS ENNEN 15 5 3 DECODING VOICE SELECTIONS ese ee se ses eke se gee se se ee se see ek ek
24. code data to the selected case No Case Conversion Convert All to Upper Case Convert All to Lower Case Page 11 of 65 T T urn off urn on USB Keystroke Delay This parameter sets the delay in milliseconds between emulated keystrokes Scan a bar code below to increase the delay when hosts require a slower transmission of data No Delay Medium Delay 20 msec Long Delay 40 msec Numeric Keypad Mode Send numeric characters as 1f entered from a numeric keypad O On ff Ctrl ASCII Mode The digital scanner sends key combinations for ASCII control characters for values 00 1F Refer to Keyboard Function Relationships Off On Page 12 of 65 Turn off Turn on ASCII Value HEX Full ASCII CTRL Bo Keyboard Function Relationships The last five characters in the Full ASCII CTRL column ON 6 apply to US only The following chart indicates the equivalents of these five characters for different countries Codes rmn IJTI A a IE ele Scandinavia f8 J lt J9 J6 France la le ls to l Germany oo loo JA ft J Ed EE ae Tee Fa Switzerland J IIe f2 Died Kingdom AL Hp Ga EE RW E ee OMA TU See TAR Teen VEO SHO Tenang P Page 13 of 65
25. e 27 of 65 Turn on Enable Max Length 48 T Turn off urn on 8 2 UCC EAN 8 Set All Default II HA Disable Enable H H Don t Transmit Check Digit Transmit Check Digit UI H 2 Digit Addenda OFF 2 Digit Addenda ON HA H 5 Digit Addenda OFF 5 Digit Addenda ON LU H Don t Extend ToEAN 13 Extend To EAN 13 Page 28 of 65 T Turn off urn on 8 3 EAN 13 Bi Set All Default III Hi Disable Enable HIN IN Don t Transmit Check Digit Transmit Check Digit III DI 2 Digit Addenda OFF 2 Digit Addenda ON i UI 5 Digit Addenda OFF 5 Digit Addenda ON Page 29 of 65 Turn off 8 4 UPC E Disable Don t Transmit Check Digit 2 Digit Addenda OFF 5 Digit Addenda OFF Page Set All Default 30 of 65 Turn on Enable
26. efault prefix order CodelD prefix AIM prefix self prefix CodeID AIM self prefix CodeID self prefix AIM AIM CodeID self prefix AIM self prefix CodeID Self prefix CodeID AIM Self prefix AIM CodeID Page 16 of 65 T T urn off urn on 6 3 Self prefix selections Disable self prefix ignore user defined prefix when decoding Enable self prefix decode all digit including user defined prefix Set user defined prefix Prefix should be used with the code of Hex Number and Save Maximum digit length of prefix is 10 characters To set self prefix firstly refers self setting to ASCII table for prefix hex characters Secondly read the Define Self prefix code as bellow Thirdly read prefix hex characters in order Finally read Save code For example set pre fix to be CODE ASCII hex value is 43 4F 44 45 the Define Self prefix code as bellow should be read then data code 434F4445 should be read To complete the setting read Save code Disable Self prefix kas Enable Self prefix Define Self prefix 6 4 Self suffix selections Disable self suffix ignore user defined prefix when decoding Enable self suffix decode all digit including user d
27. efined prefix Set user defined suffix Suffix should be used with code of Hex Number and Save Maximum digit length of suffix is 10 characters To set self suffix firstly refers self setting to ASCII table for suffix hex characters Secondly read the Define Self suffix code as bellow Thirdly read suffix hex characters in order Finally read Save code For example set suffix to be CODE ASCII hex value is 43 4F 44 45 the Define Self suffix code as bellow should be read then data code 434F4445 should be read To complete the setting read Save code Disable Self suffix EE Enable Self suffix Define Self suffix Page 17 of 65 T T urn off urn on 6 5 AIM selections Disable decode without AIM prefix One character mode decode add one AIM digit which is c Two character mode decode add two AIM digits which is cm Full mode decode add all AIM digits which is Jem Disable 2 Only Enable One Character Only Enable Two Characters Enable All 6 6 CodelD selections Disable Enable All codes use default CodeID Page 18 of 65 T T urn off urn on 6 7 Define 1D Code
28. gth 3116 Page 47 of 65 T T urn off urn on Double DataMatrix setting Double DataMatrix 2 parallel DataMatrixs vertical or horizontal Double DataMatrix setting includes read single DataMatrix only read Double DataMatrixs only and read both types Read single DataMatrix only device read only one row of DataMatrix at a time Read Double DataMatrixs only On a map device must be detected two DataMatrix and decoding success then sent decoding information Both types On a map when device detected Double DataMatrix and decoding success then sent decoding information or else Read single DataMatrix Read single DataMatrix only ka Read Double DataMatrixs only Both types Page 48 of 65 Turn off Turn on 9 6 Chinese Information Code Set all default Disable Enable Message Length In order to reduce the chances of a misread the best way is to predefine data length in advance Please read below bar code Setup to define both minimum length and maximum length according to your requirements And pay attention to the following notes 21 Both minimum and maximum lengths must not be zero 22 Minimum length should be smaller than maximum length 23 If both minimum length and maximum lengths are
29. ld a batch command Batch command can contain many commands Each command is divided by semicolon Batch command must be ended with save command Command structure command equal mark setting information The setting command list is provided below There are 4 setting command modes 1 Setting syntax 1 Command The most command is the one can be set at one time without the command e g The command setting the baud rate as 38400 bps 0100060 The command setting auto barcode reading 0302010 2 Setting syntax 2 Command equal mark number This command is used for setting the value of parameter including the longest and shortest length of the barcode barcode reading delay setting same delay time setting sensitive value setting barcode reading times setting non standard parameter etc e g The command setting the delay of barcode reading as 3000ms 0313000 3000 The command setting the sensitive value as 10 0312040 10 3 Setting syntax 3 command equal mark hex e g Ox101a 0x2C03 This command can be used as setting the user defined prefix user defined suffix ending suffix CodeID increase or cancel the barcode length value information intercepting etc Note every two hexes in the command stand for a setting character e g Append the fixed length 4 of interleaved 20f 5 to 26 0405160 0x041a Setting the suffix information of the ending as CR LF 0310000 0x0d0a 4 Setting syntax 4 command equal mark
30. ll 1D Bar Codes Disable Set All 1D Bar Codes Enable Set all 2D Bar Codes Disable Set All 2D Bar Codes Enable 1D barcode read single code onl Default Overall Setup 1D barcode read both parallel and single 1D barcode read parallel code only Enable user defined batch setting Enable device ESN number setting Save current setting to be default 0000110 0000120 0001000 0001010 0001020 0001030 0001040 0001050 0001060 0001070 0001080 0001090 001110 0001130 0001150 001160 Don t display when power on Default Display when power on Page 58 of 65 16 2 Communication 1100000 RS232 Only for EM2027 and 1100010 USB DataPipe HR200 C icati ommunication 1100020 HID KBW Only for EM1030 type EM2027 and HR200 1100040 BlueTooth Only for HR200 Only for EM2027 and 1100060 USB COM Port Emulation HR200 0100000 BaudRate 1200bps JL 0100010 Bad Rate 2400bps 0100020 BaudRate 4800bps RS232 0100050 BaudRate 19200bps LL 0100060 BaudRate 38400bps qp 0100070 BaudRate 57600bps 0100080 BaudRate 115200bps Le 0101010 Verify code even verify 0101020 Verify code odd verify Stop code two stops Dees 0103000 Data code Sdigits oo 10193010 Data code 6digis ooo LL 0103020 Datacode 7digis 1103000 Set keyboard for languages qp 1103020 CapsLockon N
31. n Length 2 Don t Transmit Start Stop Characters Note Start amp Stop Characters are A B CandD Page 39 of 65 Turn on Enable Max Length 60 Transmit Start Stop Characters Turn off Turn on 8 10 CODE93 Set All Default Disable Enable Min Length 1 Max Length 48 8 11 UCC EAN 128 setting Set All Default Disable Enable Page 40 of 65 T urn off T urn on Chapter 9 2D Symbologies Setup All available 2D bar codes are PDF417 QR Code Aztec Chinese Information Code and DataMatriXo Message Length In order to reduce the chances of a misread the best way is to predefine data length in advance Please scan below bar code Setup to define both minimum length and maximum length according to your requirements And pay attention to the following notes 1 Both minimum and maximum lengths must not be zero 2 Minimum length should be smaller than maximum length 3 If both minimum length and maximum lengths are the same read one length only 4 The maximum length for any 2D bar code should be not more than 65335 5 Save 1s required after reading the code above Page 41 of 65
32. ntinue Scan 7 2 CMOS Sensibility selections Sensibility the sense to the environment when the module under auto scan modeo Low Normal High Higher Set value of sensitivity Max 20 Page 24 of 65 T T urn off II 7 3 Delay Time selections Under Auto Scan mode LED will be on when CMOS sense bar code which will last for 2000ms if not read successfully For same bar code system will delay 1500ms to avoid duplicate reading For example to change delay time to 2350ms Step 1 scan Delay Time of Each Reading Step 2 scan 2 3 5 0 and Save Delay Time of Each Reading No Duplicate Reading Completely delay Don t read the same code within a certain period Incompletely delay It is not of absoluteness for the time to read a same barcode that is still able to read the same barcode even when the environment around is changed For example to put a barcode within a reading area remove it away after reading and return to the area again it is still able to read just the same even though it does not yet reach the same enactment time to read the code Incompletely delay Completely delay 7 4 Vibration motor control parameters selections NOTE It is only available for PD6331 Tu
33. odes with 8 to 12 characters Min Length 8 Max Length 12 Step 1 Find the bar code type Step 2 scan Min Length Step 3 scan 8 see Appendix A Step 4 scan Save Step 5 san Max Length Step 6 scan 1 2 and Save Min Message Length Default 1 Max Message Length Default 3832 Page 46 of 65 Turn on 9 5 DataMatrix Set All Default Disable Enable Message Length In order to reduce the chances of a misread the best way is to predefine data length in advance Please read below bar code Setup to define both minimum length and maximum length according to your requirements And pay attention to the following notes 16 Both minimum and maximum lengths must not be zero 17 Minimum length should be smaller than maximum length 18 If both minimum length and maximum lengths are the same read one length only 19 The maximum length for any 2D bar code should be not more than 65535 20 Save is required after reading the code above e g Decode only those bar codes with 8 to 12 characters Min Length 8 Max Length 12 Step 1 Find the bar code type Step 2 scan Min Length Step 3 scan 8 see Appendix A Step 4 scan Save Step 5 san Max Length Step 6 scan 1 2 and Save Min Length 1 Max Len
34. ooo Disable Ud 0401030 Don t Transmit Check Character UCC EAN 8 0401050 2 Digit Addenda OFF Default Default Default 0402010 Disable 0402030 Dont Transmit Check Character 0 0402060 2 Digit AddendaON np 0402080 SDigit AddendaON 0403010 Dise ______ 0403030 Dont Transmit Check Character 0403060 2DistAddendaON 0403080 SDigitaddendaON 0403100 Transmit Precursor 043120 Expand ToUPC A N 9404010 Disable Default efault efault Default 0404080 5 Digit AddendaON Y 0404100 Transmit Precursor P0 Page 62 of 65 0405010 Disable o 0405060 Validate Check Digit But Dont Transmit 0405070 Validate Check Digit and Transmit Interleaved 2 of 5 0405090 Set ITF14 Enable But Dont Transmit Check Digit 0405100 Set ITFI4 Enable And Transmit Check Digit f 0405120 Set ITF6 Enable But Dont Transmit Check Digit 0405130 Set ITF6 Enable And TransmitCheckDigit Set Interleaved 2 Of 5 Fixed Message Length Enable 0405160 Set Interleaved 2 Of 5 Fixed Message Length Value Cancel Define Fixed Length range i wi 0406020 Enable Aes Set The Max Message Length Value 0406060 Validate Check Digit But Dont Transmit 0406070 Validate Check Digit and Transmit o O 408010 Disable Set The Min Message Length Value eae 0408060 Validate Check Digit But Dont Transmit 0408070 Validate
35. rn off Turn on Set time of vibration 0 20000ms Page 25 of 65 T urn off T urn on Chapter 8 1D Symbologies Setup All available 1D codes are CODE 128 UCC EAN 128 EAN 8 EAN 13 UPC E UPC A INTERLEAVED 20F5 ITF14 ITF6 ChinaPost25 CODE 39 CODABAR CODA93 Message Length In order to reduce the chances of a misread the best way is to predefine data length in advance Please read below bar code Setup to define both minimum length and maximum length according to your requirements And pay attention to the following notes 1 Both minimum and maximum lengths must not be zero 2 Minimum length should be smaller than maximum length 3 If both minimum length and maximum lengths are the same read one length only 4 The maximum length for any 1D bar code should be not more than 127 5 Save 1s required after reading the code above e g Decode only those bar codes with 8 to 12 characters Min Length 8 Max Length 12 Step 1 Find the bar code type Step 2 scan Min Length Step 3 scan 8 see Appendix A Step 4 scan Save Step 5 san Max Length Step 6 scan 1 2 and Save Page 26 of 65 Turn off 8 1 CODE 128 Disable Min Length 1 Set All Default Pag
36. t Add 2 AIM Prefix Characters To Decoding Result Add all AIM Prefix Characters To Decoding Default 0308010 0308020 0308030 Result 0307000 Disable CodelD 0307020 All Barcode use default CodelD 0004020 Code128 Sen 0004030 UCC BAN 128 His 1D CodelD TN E N eer ETA E Page 60 of 65 ES ES 0004070 UPC A 0004080 Interleaved 2 of 5 o 0 ID CodelD 0004110 China Post 25 oC Default 0005000 PDF417 0005010 QR Code 2D CodeID 0005020 Aztec 0005030 DataMatrix 0005070 Chinese Information Code Data Packed 0314000 et Data acked Selection 0314010 Set Data Packed 0315000___ Disable Intercept message 0315010 Enable Ee 0316000 Set Intercept message Mode A 0309000 Disable Terminator Terminator 0309010 Enable Terminator i Selection 0310000 Set Message Of Terminator Po FE 16 5 Decoding Mode Definition Reading mode 0302010 Auto scan SS 0302020 Continue scan OA Set Sensibility Low Set Sensibility Normal Set Sensibility High Sensibility Set Sensibility Higher E Default Value Is 2 0312040 Set value of Sensibility max value is 20 0313020 Incompletely delay 0313030 Completely delay Reg GOO Tumor Vibration motor control 1216020 Set time of vibration 0 20000 ms 0313000 Set Delay Of Reading Default Value Is 2s 0313010 Set No Duplicate Reading time Default Value Is 1 5s Delay time Page 61 of 65 16 6 1D Symbologies Setup 0400010 Disable _____ Code128
37. taPipe only for EM2027 and HR200 HID KBW only for EM1030 USB EM2027 and HR200 BlueTooth only for HR200 USB COM Port Emulation only for EM2027 and HR200 RS232 USB DataPipe HID KBW BlueTooth USB COM Port Emulation Page 7 of 65 T T urn off urn on 4 2 RS232 selections Baud Rate setting Baud Rate sends the data from the reader to the terminal at the specified rate The host terminal must be set for the same rate as the reader Range from 1200bit s to 115200bit s 1200 4800 14400 38400 2400 9600 19200 57600 T T urn off urn on Verify selection There are 3 types of verify modes No verify Even verify and Odd verify Client must use the same verify modes to ensure the reliability of data No verify Even verify Odd verify Word length stop bits selection 1 stop bit 2stop bits Word length data bits selection This selection allows you to set the word length at 5 6 7 or 8 If an application requires only ASCII Hex characters between 0x00 and Ox7f select 7 data bits For applications requiring use to the full ASCII set select 8 data bits per character 5 data bits 6 data bits