Home
Series 6000 LHC VME64x-Crate User Manual - W-IE-NE
Contents
1. Series 6000 LHC VME64x Crate User Manual User s Manual VME 6021 CERN W Ie Ne R Plein amp Baus GmbH General Remarks The only purpose of this manual is a description of the product It must not be interpreted as a declaration of conformity for this product including the product and software W Ie Ne R revises this product and manual without notice Differences of the description in manual and product are possible W Ie Ne R excludes completely any liability for loss of profits loss of business loss of use or data interrupt of business or for indirect special incidental or consequential damages of any kind even if W Ie Ne R has been advises of the possibility of such damages arising from any defect or error in this manual or product Any use of the product which may influence health of human beings requires the express written permission of W Ie Ne R Products mentioned in this manual are mentioned for identification purposes only Product names appearing in this manual may or may not be registered trademarks or copyrights of their respective companies No part of this product including the product and the software may be reproduced transmitted transcribed stored in a retrieval system or translated into any language in any form by any means with the express written permission of W Ie Ne R Detailed Information This User Manual contains only rudimentary information to operate the device To perform insta
2. 0 temperature rise K Py 100W Pv 200W Pv 300W Py 400W Pv 500W Pv 600W Pv 700W Pv 800W Pv 900W Pv 1000W 5 Liter Minute Witer Minute Flow Pressure flow rate l min o 0 2 4 6 8 10 12 14 differential pressure 1015 Pa 02 05 06 8 00647 A1 User s Manual VME 6021 CERN W Ie Ne R Plein amp Baus GmbH 3 Conformity Certificate Holder Product Identification CE Ret OF icG ATTE of Conformity Low Voltage Directive 73 23 EEC as last amended by EEC Directive 93 68 EEC Registration No AN 60005031 0001 Report No 21106169 001 Plein amp Baus GmbH Wiener Elektronik M llersbaum 20 51399 Burscheid Deutschland Schaltnetzteil Switching Power Supply Type designation UEP 6021 LHC9U Input voltage Output voltages Output current Protection class 300 A 1 100 240 V AC 50 60 Hz 12 V 10 A 12 V 48 V 10 A 12 A 5 V 3 3 V 100 A 02 05 06 9 Serial No Engin sample This certificate of conformity is based on an evaluation of a sample of the above mentioned product Technical Report and documentation are at the Licence Holder s disposal This is to certify that the tested sample is in conformity with all revision of Annex of Council Directive 73 23 EEC in its latest amended version referred to as the Low Voltage Directive This certificate does not imply assessment of the series production of the prod
3. N 61000 6 2 2001 0 50 C without derating Storage 30 C 85 C 6 00647 A1 2 2 User s Manual W Ie Ne R Plein amp Baus GmbH VME 6021 CERN Temp coefficient Stability conditions const Current limits Voltage rise characteristics Protection Provisions Overvoltage crow bar protection DC Off trip off fan fail Overtemperature Air cooled Water cooled lt 0 2 10K 10mV or 0 1 24 hours 25mV or 0 3 6 month adjustable to any lower level monotonic 50ms processor controlled trip off adjusted to 125 of nominal voltage each output within Sms if gt 5 2 5 2 5V output deviation from nominal values adjustable after overload overheat overvoltage undervoltage bad status and DC Off trip off if temperatures exceed 110 C heat sink 70 C ambient if heat exchanger temperature exceed 80 C Trip off points adjustable processor controlled Output capacitors will be discharged by the crow bars Overpressure Water cooled versions 16 18 bar adjusted relief valve 02 05 06 7 00647 A1 User s Manual VME 6021 CERN W Ie Ne R Plein amp Baus GmbH 2 3 Water cooled Versions Flow Rates Measured graphs of a typical power supply 5 modules Water temperature rise at different flow rates power dissipation as parameter 16 00 14 00 m 12 00 S E 10 00 8 00 6 00 2 400 0 00 Te po 0 00 2 00 4 00 6 00 8 00 10 0
4. al components remains under high voltage about 400VDC When this switch is in OFF Position O all other functions are disabled including any remote control action remote monitoring is possible Also the Main Switch at fan tray front panel doesn t work until the rear rocker switch is in ON position again Liquid cooled Power Supplies Liquid water cooled power supplies wit item numbers OP07 xxxx and OP17 xxxx should be always operated with an adequate water flow see 02 3 OPO7 xxxx is still equipped with aluminum heat exchanger OP17 xxxx with stainless steel pipes Two water taps input output with integrated valves are installed at the rear side of the power supply The tap valves are closed when the mating parts have been removed An overpressure valve prevents damages of the cooling circuit by overpressure ATTENTION Do not readjust the brass screw of the valve Fan Tray Operation and Control All monitoring and control operations are performed by a micro processor based alarm and control circuit placed inside the UEP 6021 power supply monitored by UEL 6020 fan trays The reasons of a trip off will be displayed on the alphanumerical display and monitored via network CANbus Voltages currents cooling air temperatures fan speed power dissipation of inserted modules operation time of power supply and fan tray and net parameters can be shown on the fan tray display 1 3 1 Hot Swapping of LX Fan Tray If t
5. ated with typical efficiency of 75 115VAC 1 380Wnom 1580Wpeak 230VAC 2 760W 3170Wpeak modules selected for 64x application 5V 3 3V 12V 48V Available modules Type Type Type Type Type MEH 2 2 MEH Tess MEH 30 MDL Tass MDH des Regulation static MEH 550W 650W MDL MDH dyn MEH MDL MDH Recovery time 25 load Modules 550W Modules 650W MDL MDH Sense compensation range Noise and Ripple at Backplane side at Power Supply output Efficiency MTBF Power Supply air cooled Power supply water cooled EMI RF emission CE EMC immunity CE Operation temperature 02 05 06 min to max range 7 0V 60V 24V max output peak nominal output 115A 630W 100A 550W 16V 46A 630W 40A 550W 13 5A 650W 12A 580W 11 5A 2x276W 10A 2x240W 14V 23A 2x276W 20A 2x280W lt 15mV 100 load full mains range lt 0 05 100 load full mains range lt 100mV 50 lt gt 75 load 1A us lt 0 7 25 load 1A us within 1 within 0 1 lt 0 2ms lt 0 5ms lt 0 5ms lt 1 0ms 0 0ms lt 1 0ms full difference between min and max output voltage OVP has to be adjusted accordingly lt 20mVpp 0 20MHz lt 3mVrms 0 2MHz lt 40mVpp 0 20MHz lt 3mVrms 0 2MHz 68 85 depends on used modules 40 C ambient gt 65 000 h 25 C ambient gt 100 000h 20 40 C water 40 C ambient gt 100 000h EN 61000 6 3 2001 E
6. cable article no Type nom et si n cessaire n d article du produit mit den folgenden Normen bzw normativen Dokumenten tibereinstimmt is in accordance with the following standards or standardized documents est conforme aux normes ou sp cifications Europ ennes suivantes 1 EN 61 000 6 3 2001 St raussendung EMA RF emission EN 55 022 1998 St rspannung conducted noise Corr 2001 A1 2000 Kl B EN 55 022 1998 St rfeldst rke radiated noise Corr 2001 A1 2000 KI B EN 61 000 3 2 2001 Oberschwingungen harmonics EN 61 000 3 3 1995 Corr 1997 A1 2001 Spannungsschwankungen flicker 2 EN 61 000 6 2 2001 St rfestigkeit EMB immunity EN 61 000 4 6 1996 A1 2001 HF Einstr mung injected HF currents EN 61 000 4 3 1996 A1 1998 A2 2001 HF Felder radiated HF fields incl 900MHz EN 61 000 4 4 1995 A1 2001 Burst EN 61 000 4 5 1995 A1 2001 Surge EN 61 000 4 11 1994 A1 2000 Spannungs Variationen voltage variations EN 61 000 4 2 1995 A1 1998 A2 2001 ESD Folgende Betriebsbedingungen und Einsatzumgebungen sind vorauszusetzen The following operating conditions and installation arrangements have to be presumed Les conditions d op ration et d installation suivantes sont respecter Dieser Erkl rung liegt zugrunde der Priifbericht This confirmation is based on testreport Cette confirmation est bas e sur report de test 21106924 001 TUV Rheinland Product Safety GmbH 51101 K ln Allemagne J
7. h beside the HIRSCHMANN connector to switch into standby Color of the Wire black or brown AAN Pin3 notconnected 02 05 06 2 00647 A1 User s Manual VME 6021 CERN W Ie Ne R Plein amp Baus GmbH Content 1 Operation Function and Connections uessesseesseessensensnersneennnennnnsnnesnnnsnnennnennse nme nn 4 1 1 Power Supply Main Switeh 2 2 us oir cisnes een 4 1 2 Liquid cooled Power Supplies cee eecesceeescesseceseceseceseceseeeseeeseeseeeseeeseaeeeaeeeaaeenaes 4 1 3 Fan Tray Operation and Control zuessesseessnersnessnnesnnesnnesnnesnnennnennnennnnnnnnennnensn ern 4 1 3 1 Hot Swapping of LX Fan Tray u ursesssersnessnessnnesnnesnnesnnesnennnnnnnnnnensnnnen 4 1 3 2 LX fan tray UEL 6020 Front panel with CANbus Connectors eene 5 2 Technical Details en Ba Ir cee 6 2 Mas oi Were ara ar si ER ea Rey pe DE ee 6 2 2 Protection Provisions ansiada idas 7 2 3 Water cooled Versions Flow Rates coccccccnonococononononononononononononononononononononinininincnnoss 8 3 Conformity Certificaten innii tad 9 02 05 06 3 00647 A1 1 1 1 2 1 3 User s Manual VME 6021 CERN W Ie Ne R Plein amp Baus GmbH Operation Function and Connections Power Supply Main Switch A rocker switch for AC on off is situated at the rear side of the power supply Please note that this connector do not disconnect the power supply from mains completely Many intern
8. he hot swap function is activated AUTO OFF the crate can be full powered during withdrawal of the fan tray The power supply will trip off to prevent damage of inserted modules 1 if the operating time with removed fan tray is too long 30 seconds 2 when the programmed second limit of slot 1 temperature sensor or of optional installed ones exceed 02 05 06 4 00647 A1 User s Manual VME 6021 CERN W Ie Ne R Plein amp Baus GmbH SYS Reset Switch protected Power On LED Main Switch ON OFF Trip off Rest Made in Germany by Plein amp Baus GmbH Status LEDs Status Fan Fail Over Heat SYS Fail U OVER Hear sya rar STATUS US FAN FAR Alphanumeric Display E E MODE SELECT Switch Zu Fan SPEED Switch and LED AUTO OFF Switch and LED Network ADDRess Switch 3 LOCAL Switch and LED E a GU G CANbus connector 1 female Be gt CANbus connector 2 male 1 3 2 LX fan tray UEL 6020 Front panel with CANbus Connectors 02 05 06 5 00647 A1 2 1 User s Manual W Ie Ne R Plein amp Baus GmbH VME 6021 CERN Technical Details Rated Input Voltage Rated Input Current 16 A Sinusoidal CE Inrush current Output Insulation SELF CE 106 230 V AC 15 variation allowed EN 60555 IEC 555 pow fact 0 98 230V AC 16 A cold unit EN 60950 ISO 380 VDE 0805 UL 1950 C22 2 950 DC Output power with different input voltages at the rated current 16A calcul
9. iirgen Baus Techn Director Name Anschrift Datum und Unterschrift des rechtsverbindlich Verantwortlichen Name address date and legally binding signature of the person being responsible Nom adresse date et signature de la personne responsable 02 05 06 10 00647 A1
10. llation and maintainance tasks it is necessary to read the Series 6000 LHC VME64x Crate Technical Manual order no 00571 Control Cabinet In the context of this user manual the control cabinet must fulfill the requirements on fire protective enclosures according to EN 60950 IEC 60950 UL 60950 The device is intended for operation in control cabinets or in closed areas If operated outside of a control cabinet the front and back of the crate must be closed by the front pannels of the inserted VME Modules Transition Modules or by a well fitted front plate The LAN connection must be done via a shielded cable with conductive connector shells which are fixed with screws Furthermore an additional fire protective enclosure is required which must not affect proper air circulation Mains Voltage and Connection The Power supplies are equipped with a World mains input rated voltage range 100 240 VAC frequency 50 60 Hz rated current 16 A Before connecting to the mains please double check correspondence Mains input connection at the power supply side is done with a 3 pin HIRSCHMANN connector or power terminals There is no main fuse inside A circuit breaker for overcurrent protection 16A type B or C EN IEC 60898 VDE 0641 has to be installed externally Before disconnection the HIRSCHMANN connector the power supply should be switched into standby state Use the ON OFF Switch of the fan tray or the rocker switc
11. uct and does not permit the use of a T V Rheinland mark of conformity The holder of the certificate is authorized to use this certificate in connection with the EC declaration of conformity according to Annex Ill of the Directive Cologne __ 22 05 2003 T V Rheinland Product Safety GmbH Am Grauen Stein D 51105 K ln The CE marking may be used if all relevant and effective EC Directives are complied with CE 00647 A1 User s Manual VME 6021 CERN W Ie Ne R Plein amp Baus GmbH EG Konformit tserkl rung nach Artikel 10 1 der Richtlinie 89 336 EWG EMV Richtlinie EC Declaration of Conformity acc to Article 10 1 of the Directive 89 336 EEC EMC Directive D claration de conformit CEE selon Particle 10 1 de la directive 89 336 CEE Directive EMC Wi W IE NE R Plein amp Baus GmbH We Miillersbaum 20 Nous 51399 Burscheid Hilgen Name und Anschrift des Herstellers oder des in der EU niedergelassenen Inverkehrbringers Name and address of the manufacturer or of the introducer of the product who is established in the EU Nom et adresse du fabricant ou le la personne r sidant dans la CEE qui introduit le sous dit produit de la CEE erkl ren in alleiniger Verantwortung da das Produkt herewith take the sole responsibility to confirm that the product soussign s d clarons de notre seule responsabilit que ce produit Series 6000 LHC VME64x Crate Typenbezeichnung und ggf Artikel Nummer Type designation and if appli
Download Pdf Manuals
Related Search
Related Contents
Mini-Display HL975 User Manual Z 114 223 Ko Softwarehandbuch für NAV - PNF 35 - a -1- 携帯の裏技 各社共通の裏技やその他 PHS に関する情報を紹介し Menu StatTools - Palisade Corporation Configuration matérielle etcommunication dans 消毒、滅菌総合ガイド - お客様相談センター Mirage™ FX ST8050 AT Command Set Guide - GSM/GPS Skypatrol Equipment Copyright © All rights reserved.