Home
indicator v3 ~ in902/in903
Contents
1. An Indicator set to a non Master address 50 20 30 C1 etc displays Program Version TOM Net address Bland screen An Indicator set to an invalid address ex 81 displays Program Version EA address EA address EA SATO Labeling Solutions America Inc 8 of 13 www satolabeling com 2007 ATURN O MATIC INDICATOR V3 IN902 IN903 INDICATOR SET UP OPTIONS V3 Master 1 Connect a Push Button to the Push Button plus port on the Indicator Restart the Indicator by disconnecting and reconnecting power Hold the Push button depressed during the Indicator start up display sequence to enter the setup options Alternatively for an Indicator pack with a Wireless Push Button hold the plus button on the Wireless Push Button depressed during the Indicator start up sequence to enter the setup options Continued on next page SATO Labeling Solutions America Inc 9 of 13 www satolabeling com 2007 ATURN O MATIC INDICATOR V3 IN902 IN903 INDICATOR SET UP OPTIONS V3 Master Continued 3 Indicator Update delay UP on multiple push button presses is displayed followed by the current setting seconds Press push button to increment setting 1 After 3 seconds with no push button presses Indicator Sleep SL is displayed followed by the current setting minutes Press push button to increment setting 1 After 3 seconds with no push button presses Ind
2. ATURN O MATIC INDICATOR V3 IN902 IN903 USER MANUAL Indicator V3 IN902 IN903 Page USER MANUAL CONTENTS __6 Indicator Address Setting V2 Systems o Z oZ oS 8 Indicator Start Up S O 9 Indicator Set Up Options V3 Master o SSS I Turn O Matic Contact Information SATO Labeling Solutions America Inc 1 of 13 www satolabeling com 2007 ATURN O MATIC INDICATOR V3 IN902 IN903 PRODUCT CONFIGURATIONS Indicator Module V3 IN902M Indicator Module V3 IN903M Indicator V3 IN902 Indicator V3 IN903 Indicator Pack V3 IN902 PB Indicator Pack V3 IN902 RF Indicator Pack V2service IN902 Indicator Pack V2service IN903 1 2 3 4 5 6 7 8 SATO Labeling Solutions America Inc 2 of 13 www satolabeling com 2007 ATURN O MATIC INDICATOR V3 IN902 IN903 CONNECTIONS amp SETTING SWITCHES ON BACK OF INDICATOR Data In Out RJ10 modular plug Power In Out 2 5mm DC plug Maximum 5m 16 1 2 ft cable length in from power supply Maximum 1m 3 ft cable length Out to next Indicator Push Buttons and RJ10 modular plug Cascade display In Out RJ10 modular plug Wireless Push Button receiver IDC 10 pin Sound tone and volume setting TOM Net address setting 12VAC 15VDC 2 A e a 12 mj aa F JUL SIL Art 3810 2800 Batch 200529 SATO Labeling Solutions America Inc 3 of 13 www satolabeling co
3. 10 hold the Push Button or the button on the Wireless Push Button depressed 3 seconds To decrease the displayed number 1 press the Push Button or the button on the Wireless Push Button SATO Labeling Solutions America Inc 12 of 13 www satolabeling com 2007 ATURN O MATIC INDICATOR V3 IN902 IN903 TURN O MATIC CONTACT INFORMATION CUSTOMER SERVICE Customer Service SATO LABELING SOLUTIONS AMERICA INC 1140 Windham Parkway Romeoville IL 60446 Customer Service Toll Free Phone 800 645 3290 Ext 8 Customer Service Direct Phone 630 771 4200 Ext 8 Customer Service Fax 630 771 4250 TECHNICAL CENTER Technical Center SATO LABELING SOLUTIONS AMERICA INC 30 Chapin Road Suite 1201 PO Box 777 Pine Brook NJ 07058 Technical Center Toll Free Phone 800 205 7611 Ext 3654 Technical Center Direct Phone 973 287 3654 Technical Center Fax 973 227 3961 SATO Labeling Solutions America Inc 13 of 13 www satolabeling com 2007
4. e settings V2 Direct 900 Master 21 Slave 20 V2 Direct 900 Parallel CD Nr 20 CD SP 30 SP1 21 SP15 2F V2 Select 900 Signal 900 Info 900 CD Nr 20 CD SP 30 SP1 21 SP15 2F 2051508 Coy ox pri a ee a ee ee ee s V2 CD Nr CD SP Direct900 Parallel i V2 CD Nr CD SP Select900 Signal900 SP15 Info900 q ERE ElectronicDispenser forSignal amp Info900 i SATO Labeling Solutions America Inc 6 of 13 www satolabeling com 2007 ATURN O MATIC INDICATOR V3 IN902 IN903 INDICATOR MOUNTING Indicator Modules click into 3mm or 6mm thick aluminum acrylic plastic panels with cutout sizes shown Indicators include a mounting bracket that must be fastened Mark hole location using bracket as template For fastening in other than solid wood use included expander plugs Screw in included wood screws but not so hard that bracket bends OPTION Indicator Ceiling Bracket 1 inch min SATO Labeling Solutions America Inc 7 of 13 www satolabeling com 2007 ATURN O MATIC INDICATOR V3 IN902 IN903 INDICATOR START UP Plug power supply into a suitable mains outlet and into the indicator An Indicator set to a Master address 51 or 21 displays Program Version TOM Net address Last number displayed at power OFF 00 000 if first start If duplicate Master NOT allowed Ed is displayed
5. icator Flashes FL on number change is displayed followed by the current setting Press push button to increment setting 1 After 3 seconds with no push button presses Indicator displays CS and saves the new settings to memory SATO SATO Labeling Solutions America Inc 0of3 Solutions America Inc 10 of 13 www satolabeling com 2007 ATURN O MATIC INDICATOR V3 IN902 IN903 INDICATOR SOUND TONE amp VOLUME SETTINGS Use a small screwdriver to change switch settings 1 Sound tone is set with switches 1 2 SW1 OFF SW2 OFF no sound for 2 or more indicators in a cluster set sound on for only one indicator SW1 OFF SW2 ON single tone SW1 ON SW2 OFF double tone SW1 ON SW2 ON triple tone 2 Sound volume is set with switches 3 4 SW3 OFF SW4 OFF low volume SW3 ON SW4 Off medium volume recommended for most installations SW3 OFF SW4 ON high volume i gt y o jm LE duo a if alla 34 SATO Labeling Solutions America Inc 11 of 13 www satolabeling com 2007 ATURN O MATIC INDICATOR V3 IN902 IN903 MASTER INDICATOR OPERATION Indicator must have and Push Buttons connected or have an installed RF receiver to use a Wireless Push Button 1 To advance the displayed number 1 press the Push Button or the button on the Wireless Push Button NOTE Master Indicator buffers up to 7 multiple push button presses To fast advance the displayed number
6. m 2007 ZZ TURN O MATIC INDICATOR V3 IN902 IN903 CONNECTION ADAPTERS Indicator V2service DC 12VAC Connect one lead to 1 and the other lead to 2 15VDC Connect minus lead to 1 and plus lead to 2 Push Button Connect one lead to 2 and the other lead to 3 Use one adapter for plus Push Button and one adapter for minus Push Button Cascade Connect one lead to 1 and the other lead to 2 TOM Net Connect shield to 1 white lead to 2 and brown lead to 3 12VAC 15 VDC 1 2 SATO Labeling Solutions America Inc 4 of 13 www satolabeling com 2007 ATURN O MATIC INDICATOR V3 IN902 IN903 INDICATOR ADDRESS SETTING V3 Systems Disconnect power to the Indicator Use a small screwdriver to rotate address switches to these settings S3 Master 51 Slave 50 M3 CD Nr 50 CD SP 60 SP1 51 SP15 5F L3 CD Nr ST A E C1 C5 CD SP ST A E D1 D5 Recall Nr ST A E CA CE Recall SP ST A E DA DE SP1 51 SP16 61 SP30 6F HCW ST A E BA BE HAP B9 AWT ST A E 3A 3E DSN ST A E 31 35 o Pe g dili s O a CLO Bol ox SATO Labeling Solutions America Inc 5 of 13 www satolabeling com 2007 ATURN O MATIC INDICATOR V3 IN902 IN903 INDICATOR ADDRESS SETTING V2 Systems Disconnect power to the Indicator Use a small screwdriver to rotate address switches to thes