1. if included your monitoring station of an emergency situation Security systems are generally very reliable but they may not work under all conditions and they are not a substitute for prudent security practices or life and property insurance Your security system should be installed and serviced by qualified security professionals who should instruct you on the level of protection that has been provided and on system operations System Information Fill out the following information for future reference and store this manual in a safe place Access Codes Your Master Code is Additional Access Codes 01 09 17 25 02 10 18 26 03 11 19 27 04 12 20 28 05 13 21 29 06 14 22 30 07 15 23 31 08 16 24 32 Zone Information Zone Protected Area Zone Type o N DOAK OUN Keypad Zone F FIRE Keypad Zone A AUXILIARY Keypad Zone P PANIC The Exit Delay Time is seconds The Entry Delay Time is seconds For Service Monitoring Station Information Account Telephone Installer Information Company Telephone Access Codes Access Codes are used to arm and disarm the system There are 33 access codes available one Master Code and 32 access codes Only the Master Code can be used to program additional security codes and to change other system features as well as to arm and disarm the security system The Master Code will be supplied to you by your installer All keypad entries are made by pressing one key at a
2. About Your Security System Your DSC security equipment has been designed to provide you with the greatest possible flexibility and convenience Read this manual carefully and have your installer instruct you on your system s operation and on which features have been implemented in your system All users of this system should be equally instructed in its use Fill out the System Information page with all of you zone information and access codes and store this manual in a safe place for future reference Fire Detection This equipment is capable of monitoring fire detection devices such as smoke detectors and providing a warning if a fire condition is detected Good fire detection depends on having adequate number of detectors placed in appropriate locations This equipment should be installed in accordance with N F P A standard 72 N F P A Batterymarch Park Quincey MA 02269 Carefully review the Family Escape Planning guidelines in this manual NOTE Your installer must enable the fire detection portion of this equipment before it becomes functional Testing To insure that your system continues to function as intended you must test your system weekly Please refer to Testing Your System on page 13 of this manual If your system does not function properly call your installing company for service Monitoring This system is capable of transmitting alarms troubles and emergency information over telephone lines to a monitoring st
3. CHANGES IN TELEPHONE COMPANY EQUIPMENT OR FACILITIES The telephone company may make changes in its communications facilities equipment operations or procedures where such actions are reasonably required and proper in its business Should any such changes render the customer s terminal equipment incompatible with the telephone company facilities the customer shall be given adequate notice to the effect modifications to maintain uninterrupted service RINGER EQUIVALENCE NUMBER REN The RENis useful to determine the quantity of devices that you may connect to your telephone line and still have all of those devices ring when your telephone number is called In most but not all areas the sum of the RENs of all devices connected to one line should not exceed five 5 0 To be certain of the number of devices that you may connect to your line you may want to contact your local telephone company EQUIPMENT MAINTENANCE FACILITY If you experience trouble with this telephone equipment please contact the facility indicated below for information on obtaining service or repairs The telephone company may ask that you disconnect this equipment from the network until the problem has been corrected or until you are sure that the equipment is not malfunctioning Digital Security Controls Ltd 160 Washburn St Lockport NY 14094
4. From an LED keypad observe the zone light turn ON when the zone is activated The zone light will turn OFF when the system restores to normal i e door or window closed From an LCD keypad the following message will be displayed when each zone is activated Secure System Use the arrow lt gt keys to view which zone is open This message will Before Arming lt 2 disappear when the zone is restored 5 If the panel has any fire zones activation will cause the alarm signal to sound in a pulsed mode CAUTION Do not use an open flame or burning materials to test a smoke or heat detector Contact your installer for information on safe methods of testing detectors 6 When testing is complete call and advise the monitoring station Should the system fail to function properly contact your installer NOTE Some features described above will not be functional unless enabled by your installer Please ensure that your installer has advised you which features are functional on your system Door Chime Feature The door chime feature is used to provide a tone from the keypad each time a door or window is opened or closed The doors and windows which will provide this indication are programmed by your installer To activate the door chime from an LED Keypad Enter 4 to turn the door chime feature ON and OFF When the command is entered the keypad buzzer will beep 3 times if the door chime feature is enabled and will sou
5. However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures n Re orient the receiving antenna n Increase the separation between the equipment and receiver n Connect the equipment into an outlet on a circuit different from that to which the receiver is connected n Consult the dealer or an experienced radio television technician for help The user may find the following booklet prepared by the FCC useful How to Identify and Resolve Radio Television Interference Problems This booklet is available from the U S Government Printing Office Washington D C 20402 Stock 004 000 00345 4 IMPORTANT INFORMATION This equipment complies with Part 68 of the FCC Rules On the side of this equipment is a label that contains among other information the FCC registration number of this equipment NOTIFICATION TO TELEPHONE COMPANY The customer shall notify the telephone company of the particular line to which the connection will be made and provide the FCC registration number and the ringer equivalence of the protective circuit FCC Registration Number F53CAN 32028 AL E Facility Interface Code 02LS2 Ringer Equivalence Number 0 1B Service Order Code 9 0F USOC
6. Keypad beeps Keypad displays Press 7 1 Zones with low batteries LED keypad zone lights 1 to 8 Press 7 again 2 Handheld keypads with low batteries LED keypad zone lights 1 to 4 Press 7 again 3 Wireless keys with low batteries LED keypad zone lights 1 to 8 To view the battery conditions of wireless keys 9 through 16 you must be at an LCD keypad a E Loss of time on system clock To set the system time following the instructions in Setting System Date and Time on page 12 To view troubles from an LCD Keypad From the Ready state use the arrow lt gt keys to scroll to the following message System Trouble Obey to Ulew lt gt Hiem Trouble Trouble Message Press 2 key to view the trouble The message will read z Use the arrow lt gt keys to view which troubles are present on the system Once you have scrolled through the list of troubles press the key to exit the Trouble Viewing mode and return to the Ready state 11 12 Setting the System Date and Time To set the system time enter 6 followed by the Master Code Press 1 The keypad will now accept 10 consecutive digits e Enter the Time in Hours and Minutes using the 24 Hour format 00 00 to 23 59 e Enter the Date in Months Days and Years MM DD YY NOTE If you have an LCD keypad your installer may have programmed your system to display the time and date while the keypad is idle If this
7. Entry Active Enter your access code If an error is made in entering the code re enter the Enter Your Code Code correctly When a valid access code is entered the keypad will stop beeping If no alarms occurred while the panel was armed and there are no troubles the display will read System Disarmed After about five seconds the system will return to the Ready state and the display Ho Alarm Memory will read Enter Code bo Arm System Wiew Memory lt lf an alarm occurred while the system was armed this message will be displayed Jame of Alarm Use the arrow lt gt keys to view which zones caused the alarm If a zone is still in alarm the display will show the following message to indicate that a zone is open Secure System Before Arming lt gt Enter Code ta Upon disarming and if a trouble is present this message will be displayed Use the Arm System lt 2 arrow lt gt keys to view which troubles are affecting the system see Viewing Trouble Conditions on page 11 NOTE If you return and find that an alarm has occurred while you were away it is possible that an intruder may still be on the premises Go to a neighbour s house and call the local police to investigate The alarm memory is cleared each time the panel is armed so that any alarms showing are alarms that occurred only during the last armed period If An Alarm Sounds Fire Alarm I
8. Jack RJ31X TELEPHONE CONNECTION REQUIREMENTS Except for the telephone company provided ringers all connections to the telephone network shall be made through standard plugs and telephone company provided jacks or equivalent in such a manner as to allow for easy immediate disconnection of the terminal equipment Standard jacks shall be so arranged that ifthe plug connected thereto is withdrawn no interference to the operation of the equipment at the customer s premises which remains connected to the telephone network shall occur by reason of such withdrawal INCIDENCE OF HARM Should terminal equipment or protective circuitry cause harm to the telephone network the telephone company shall where practicable notify the customer that temporary disconnection of service may be required however where prior notice is not practicable the telephone company may temporarily discontinue service if such action is deemed reasonable in the circumstances Inthe case of such temporary discontinuance the telephone company shall promptly notify the customer and will be given the opportunity to correct the situation ADDITIONAL TELEPHONE COMPANY INFORMATION The security control panel must be properly connected to the telephone line with a USOC RJ 31X telephone jack The FCC prohibits customer provided terminal equipment be connected to party lines or to be used in conjunction with coin telephone service Interconnect rules may vary from state to state
9. a two digit number from 01 to 08 As each zone is bypassed the corresponding zone light will turn ON If a zone is bypassed by mistake enter that zone number again the zone light will turn OFF indicating that the zone is not bypassed Press to return to the Ready state To bypass zones from an LCD keypad To bypass a zone the system must be in the Ready state The display will read Enter Code ta Press the x key to enter the functions menu The display will read Arm System Press iki for lt Press the key to enter the zone bypassing mode The display will read zone Bypass Fore Search lt gt Use the arrow lt gt keys to find the zone to be bypassed and press the key to Zone Hame select it The display will read Zone Search lt B will appear on the display to show that the zone is bypassed To unbypass a Fone Mame B zone enter the zone number the B will disappear from the display to show that the zone is no longer bypassed Zone Search lt This display will be shown if a zone was open when you entered the bypassing Fone Hame o COmmand The open zone will be represented by O If you bypass the open zone the O will be replaced by a B To exit the bypassing mode and return to the Ready state press the key Viewing Trouble Conditions The control panel continuously monitors a number of possible trouble condit
10. is the case you may have to press the key to clear the date and time before entering an access code to arm the system or before performing any other keypad function Testing Your System Alarm Test The Alarm Test provides two second test of the keypad sounder and bell or siren Begin with the panel in the Ready state From an LED keypad Enter 6 Master Code 4 then press to return to the Ready state From an LCD keypad press to enter the functions list Use the arrow lt gt keys to scroll to find User Functions and press to select Enter your Master Code and scroll to find the following message lect Option lt gt Press x to perform an Alarm Test The keypad will display the following message stem Test System Test Press to return to the Ready state Full System Test We recommend that you test your system weekly Should the system fail to function properly call your installation company immediately for service NOTE Perform system tests during off peak hours such as early morning or late evening 1 Inform the monitoring station that you are testing your system 2 Begin with the system in the Ready state 3 Perform a Bell Battery test by pressing 6 Master Code 4 The bell and keypad buzzer will sound for two seconds and all keypad lights will turn ON Press to exit 4 Activate each sensor in turn e g open a door window or walk in motion detector areas
11. time All access codes can be programmed by following the procedure outlined in Programming Security Codes on page 6 Arming the System Arming from an LED Keypad If the Ready light is ON the system is ready for arming If the Ready light is OFF check to see that all doors and windows are closed and that motion is stopped in areas covered by motion detectors The system cannot be armed unless the Ready light is ON indicating that all zones are closed and the system is in the Ready state Enter your access code As each digit is entered the keypad sounder will beep If the access code was entered incorrectly the keypad buzzer will sound steadily for one second If this occurs press the key and re enter your access code If the correct access code is entered the keypad sounder will beep quickly and the Armed light will come ON Exit the premises through the door indicated by your installer as the Exit Entry door The panel will provide an exit delay period indicated by keypad beeps for you to exit the premises without causing an alarm At the end of the exit delay period all keypad lights except the Armed light will turn OFF and the system will be armed The exit delay time can be changed by your installer Araning from an LCD Keypad ze System When this message appears one or more zones are not secured To secure the Arming System close all doors and windows and cease all motion in areas covered by motion detect
12. 02443 R1 eWARNING This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer The entire manual should be carefully read Instruction Manual PC1555 WARNING Please Read Carefully Note to Installers This warning contains vital information As the only individual in contact with system users it is your responsibility to bring each item in this warning to the attention of the users of this system System Failures This system has been carefully designed to be as effective as possible There are circumstances however involving fire burglary or other types of emer gencies where it may not provide protection Any alarm system of any type may be compromised deliberately or may fail to operate as expected for a variety of reasons Some but not all of these reasons may be E Inadequate Installation A security system must be installed properly in order to provide adequate protection Every installation should be evaluated by a security professional to ensure that all access points and areas are covered Locks and latches on windows and doors must be secure and operate as intended Windows doors walls ceilings and other building materials must be of sufficient strength and construction to provide the level of protection expected A reevaluation must be done during and after any construction activity An evaluation by the fire and or poli
13. See Fire Alarm Operation on page 13 Program Light The Program light will flash when you are programming access codes or performing other programming functions If someone iS programming at another keypad the Program light will turn ON to indicate that the system is busy Display Lights All Keypads Ready Light If the Ready light is ON the system is ready for arming The system cannot be armed unless the Ready light is ON see Arming the System on page 3 Armed Light If the Armed light is ON the system has been armed successfully Trouble or System Light If the Trouble light is ON see Viewing Trouble Conditions on page 11 O O Os OOO lt i Chime 4 9 Q Reset ete A i O00 GD l Message Display Security Station Press to select function Press to Exit Return lt gt Indicates more information is available Press either key to view gt Press to advance display to the next function or message T TEST SYSTEM WEEKLY Refer to Instruction Manual for testing instructions lt Press to see previous function or message x X R f Nal Nd N The Liquid Crystal Display LCD disp information on two 16 character lines ays prompts and system If lt gt appears more information can be accessed by using the arrow lt gt keys Press lt to see the previous function or item of information Press gt to advance the display t
14. asons some of which follow The smoke detectors may have been improperly installed or positioned Smoke may not be able to reach the smoke detectors such as when the fire is in a chimney walls or roofs or on the other side of closed doors Smoke detectors may not detect smoke from fires on another level of the residence or building Every fire is different in the amount of smoke produced and the rate of burning Smoke detectors cannot sense all types of fires equally well Smoke detectors may not provide timely warning of fires caused by carelessness or safety hazards such as smoking in bed violent explosions escaping gas improper storage of flammable materials overloaded electrical circuits chil dren playing with matches or arson Even if the smoke detector operates as intended there may be circumstances when there is insufficient warning to allow all occupants to escape in time to avoid injury or death E Motion Detectors Motion detectors can only detect motion within the designated areas as shown in their respective installation instructions They cannot discrimi nate between intruders and intended occupants Motion detectors do not provide volumetric area protection They have multiple beams of detec tion and motion can only be detected in unobstructed areas covered by these beams They cannot detect motion which occurs behind walls ceil ings floor closed doors glass partitions glass doors or windows Any type of tampering wh
15. ation If you inadvertently initiate an alarm immediately call the monitoring station to prevent an unnecessary response NOTE The monitoring function must be enabled by the installer before it becomes functional General System Operation Your security system is made up of a DSC control panel one or more keypads and various sensors and detectors The control panel will be mounted out of the way in a utility closet or in a basement The metal cabinet contains the system electronics fuses and stand by battery There is normally no reason for anyone but the installer or service professional to have access to the control panel All the keypads have an audible indicator and command entry keys The LED keypads have a group of zone and system status lights The LCD keypad has an alphanumeric liquid crystal display LCD The keypad is used to send commands to the system and to display the current system status The keypad s will be mounted in a convenient location inside the protected premises close to the entry exit door s The security system has several zones of area protection and each of these zones will be connected to one or more sensors motion detectors glassbreak detectors door contacts etc A sensor in alarm will be indicated by the corresponding zone lights flashing on a LED keypad or by written messages on the LCD keypad IMPORTANT NOTICE A security system cannot prevent emergencies It is only intended to alert you and
16. ber should participate in developing the escape plan 2 Study the possible escape routes from each location within the house Since many fires occur at night special attention should be given to the escape routes from sleeping quarters 3 Escape from a bedroom must be possible without opening the interior door Consider the following when making your escape plans Make sure that all perimeter doors and windows are easily opened Ensure that they are not painted shut and that their locking mechanisms operate smoothly f opening or using the exit is too difficult for children the elderly or handicapped plans for rescue should be developed This includes making sure that those who are to perform the rescue can promptly hear the fire warning signal f the exit is above the ground level an approved fire ladder or rope should be provided as well as training in its use Exits on the ground level should be kept clear Be sure to remove snow from exterior patio doors in winter outdoor furniture or equipment should not block exits Each person should know of a predetermined assembly point where everyone can be accounted for i e across the street or at a neighbour s house Once everyone is out of the building call the Fire Department A good plan emphasizes quick escape Do not investigate or attempt to fight the fire and do not gather belongings or pets as this wastes valuable time Once outside do not re enter the house Wait for the f
17. ce department is highly recommended if this service is available E Criminal Knowledge This system contains security features which were known to be effective at the time of manufacture It is possible for persons with criminal intent to develop techniques which reduce the effectiveness of these features It is important that a security system be reviewed periodically to ensure that its features remain effective and that it be updated or replaced if it is found that it does not provide the protection expected E Access by Intruders Intruders may enter through an unprotected access point circumvent a sensing device evade detection by moving through an area of insuffi cient coverage disconnect a warning device or interfere with or pre vent the proper operation of the system E Power Failure Control units intrusion detectors smoke detectors and many other security devices require an adequate power supply for proper operation If a device operates from batteries it is possible for the batteries to fail Even if the batteries have not failed they must be charged in good condition and in stalled correctly If a device operates only by AC power any interruption however brief will render that device inoperative while it does not have power Power interruptions of any length are often accompanied by voltage fluctua tions which may damage electronic equipment such as a security system After a power interruption has occurred immediately
18. conduct a complete system test to ensure that the system operates as intended E Failure of Replaceable Batteries This system s wireless transmitters have been designed to provide several years of battery life under normal conditions The expected battery life is a function of the device environment usage and type Ambient conditions such as high humidity high or low temperatures or large temperature fluctua tions may reduce the expected battery life While each transmitting device has a low battery monitor which identifies when the batteries need to be replaced this monitor may fail to operate as expected Regular testing and maintenance will keep the system in good operating condition E Compromise of Radio Frequency Wireless Devices Signals may not reach the receiver under all circumstances which could include metal objects placed on or near the radio path or deliberate jamming or other inadvertent radio signal interference E System Users A user may not be able to operate a panic or emergency switch possibly due to permanent or temporary physical disability inability to reach the device in time or unfamiliarity with the correct operation It is important that all system users be trained in the correct operation of the alarm system and that they know how to respond when the system indicates an alarm E Smoke Detectors Smoke detectors that are a part of this system may not properly alert occupants of a fire for a number of re
19. dicate that the system should be disarmed Go to the keypad and enter your access code If an error is made entering the code re enter your code correctly As soon as the correct code is entered the Armed light will go out and the keypad will stop beeping The correct access code must be entered before the entry delay period expires If a valid access code is not entered during this time the system will go into alarm The entry time delay may be changed by your installer If an alarm occurred while the system was armed the Memory light or System light on a PC1555RKZ keypad and the zone light corresponding to the zone which caused the alarm will flash for 30 seconds After the 30 second period the Memory or System light and zone light will stop flashing and the panel will return to the Ready state Pressing the key during the 30 second period will cancel the alarm memory display To view other alarms press 3 If a trouble was detected when the panel is disarmed the Trouble light or System light on a PC1555RKZ keypad will turn ON See Viewing Trouble Conditions on page 11 to determine the source of the trouble Please note that troubles will not display while the system is in the Alarm Memory Display mode Disarming from an LCD Keypad Upon entering through a designated Exit Entry door the keypad will beep and the entry delay will commence reminding you to disarm the system The keypad will display the following message
20. ed the keypad sounder will beep 3 times and the display will read The P means the code has been programmed If there is no P then that code is deleted Press to exit the code programming function The Master code cannot be erased Remember to record your new code s on the System Information page in this booklet PC1555RKZ LED Keypad SING Press 1 Zone Press to return t e systern IN Luse USE USE ea a Zone 3 te y i Zone 7 F A e Or NOT NoT noT rea a Ds System Zone 1 Zone 4 Zone 5 Zone 6 TEST SYSTEM WEEKLY agagaaT til System Light PC1555RKZOnly If the System light is ON one or more of these conditions could be present on the system System Busy System Troubles See Viewing Trouble Conditions on page 11 Alarm Memory See Disarming the System on page 5 Zone Bypassing See Zone Bypassing on page 10 Programming The System light will flash when you are programming access codes or performing other programming functions If someone is programming at another keypad the System light will turn ON to indicate that the system is busy NOTE If you have a PC1555RKZ keypad the System light acts as a Trouble Memory Programming and Bypass indicator Unlike the other keypads these conditions will only be represented by the System light Please keep this in mind when reading other functi
21. ether intentional or unintentional such as masking painting or spraying of any material on the lenses mirrors windows or any other part of the detection system will impair its proper operation Passive infrared motion detectors operate by sensing changes in tempera ture However their effectiveness can be reduced when the ambient tem perature rises near or above body temperature or if there are intentional or unintentional sources of heat in or near the detection area Some of these heat sources could be heaters radiators stoves barbeques fireplaces sun light steam vents lighting and so on E Warning Devices Warning devices such as sirens bells horns or strobes may not warn people or waken someone sleeping if there is an intervening wall or door If warning devices are located on a different level of the residence or premise then it is less likely that the occupants will be alerted or awak ened Audible warning devices may be interfered with by other noise sources such as stereos radios televisions air conditioners or other ap pliances or passing traffic Audible warning devices however loud may not be heard by a hearing impaired person E Telephone Lines If telephone lines are used to transmit alarms they may be out of service or busy for certain periods of time Also an intruder may cut the telephone line or defeat its operation by more sophisticated means which may be difficult to detect E Insufficient Time T
22. f your system has been installed with fire detectors and the alarm sounds in a pulsing mode follow your emergency evacuation plan immediately see Fire Escape Planning on page 15 Intrusion Alarm If an intrusion alarm sounds indicated by a continuous Bell or Siren the alarm may be silenced by entering your access code If the alarm was unintentional call local authorities immediately to avoid an unnecessary response You can determine the source of the alarm by following the instructions in the Disarming section see page 4 and 5 Once the source of the alarm has been corrected the panel can be restored to its original Armed state NOTE A fire alarm has priority over a burglary type alarm Function Keys The PC5008Z and LCD5500Z keypads have five function keys marked Stay Away Chime Reset and Exit which allow easy single button activation of the most commonly used features f these keys have been enabled by your installer you can execute the programmed function by pressing and holding the corresponding key for two seconds Corresponding function keys on the PC1555RKZ are number keys 1 to 5 respectively For more information regarding the operation of the function keys talk to your alarm system installer Programming Security Codes Programming codes from an LED Keypad The Master Code To program the Master Code enter 5 current Master Code 40 new Master Code The Master Code must be four digits unless
23. here may be circumstances when the system will operate as intended yet the occupants will not be protected from the emergency due to their inability to respond to the warnings in a timely manner If the system is monitored the response may not occur in time to protect the occupants or their belongings E Component Failure Although every effort has been made to make this system as reliable as possible the system may fail to function as intended due to the failure of a component E Inadequate Testing Most problems that would prevent an alarm system from operating as in tended can be found by regular testing and maintenance The complete sys tem should be tested weekly and immediately after a break in an attempted break in a fire a storm an earthquake an accident or any kind of con struction activity inside or outside the premises The testing should include all sensing devices keypads consoles alarm indicating devices and any other operational devices that are part of the system E Security and Insurance Regardless of its capabilities an alarm system is not a substitute for prop erty or life insurance An alarm system also is not a substitute for prop erty owners renters or other occupants to act prudently to prevent or mini mize the harmful effects of an emergency situation NOTICE The Industry Canada label identifies certified equipment This certification means that the equipment meets certain telecommunications network p
24. ions If one of these trouble conditions keypad occur the keypad will beep twice every 10 seconds until you press any key on the NOTE A TROUBLE condition reduces the security your system is designed to provide Call your installing company for service To view troubles from an LED Keypad A trouble will be indicated by the Trouble light or System light on a PC1555RKZ keypad which will remain ON until the trouble condition is cleared If you cannot determine the cause of the trouble condition contact your installer for assistance To view the type of trouble condition press 2 One or more zone lights will turn ON indicating the various trouble conditions ZONE LIGHT TYPE OF TROUBLE TD satei hands Service required Call your installation company for service Dire eaten Indicates the loss of AC power When this trouble occurs the Trouble or System light will turn ON but keypad buzzer will not sound SAAR Telephone line trouble Ao ese teas The panel has failed to communicate with the central station ee ee Zone fault Press 5 and the zone light s corresponding to the faulted zones will turn ON ere ener Zone tamper Press 6 and the zone light s corresponding to the tampered zones will turn ON T hpr Low zone battery This trouble is generated when a wireless device exhibits a low battery condition Press 7 one two or three times to view which devices are experiencing battery failure The following will occur
25. ire department Write the fire escape plan down and rehearse it frequently so that should an emergency arise everyone will know what to do Revise the plan as conditions change such as the number of people in the home or if there are changes to the building s construction Make sure your fire warning system is operational by conducting weekly tests see Fire Alarm Operation on page 13 If you are unsure about system operation contact your installing dealer We recommend that you contact your local fire department and request further information on fire safety and escape planning If available have your local fire prevention officer conduct an in house fire safety inspection Maintenance With normal use the system requires minimum maintenance The following points should be observed 1 Do not wash the security station with a wet cloth Light dusting with a slightly moistened cloth should remove normal accumulations of dust 2 The battery bell test is designed to determine battery condition We recommended however that the stand by batteries be replaced every three years 3 For other system devices such as smoke detectors passive infrared ultrasonic or microwave motion detectors or glassbreak detectors consult the respective manufacturer s literature for testing and maintenance 15 A Security Products 1997 Digital Security Controls Ltd 1645 Flint Road Downsview Ontario Canada M3J 2J6 Printed in Canada 290
26. nd one long beep if it is disabled To activate the door chime from an LCD Keypad Press to enter the function list then scroll to find Fr Press or 4 to enable or disable the Door Chime feature Press to return to Door the Ready state Fire Alarm Operation Alarm On a fire alarm the bell or siren will pulse ON and OFF The transmission of the alarm to the monitoring station is delayed for 30 seconds If the alarm is not cleared within the 30 second delay the it will be transmitted to the monitoring station Silence To silence the bell or siren press the key If the alarm is silenced and the smoke detector is not reset the alarm will resound after 90 seconds Resetting Smoke Detectors Once the smoke detector is reset if it still detects smoke the alarm sequence will resound as described above If there is no smoke the system will return to normal To reset smoke detectors from an LED Keypad Press 7 2 To reset smoke detectors from an LCD Keypad Press to enter the function list Scroll to find Press f For lt gt Press to select the output control The display will read Output Control to elect Output lt gt Use the arrow lt gt keys to find the following message and press the xX key to Uti lity Output select an elect Output lt gt Sensor Reset NOTE If you suspect that a fire alarm has transmitted and that there is no fire co
27. ndition call the monitoring station to avoid an unnecessary response f a fire condition is apparent follow your evacuation plan immediately If the alarm sounds at night evacuate immediately NOTE The description above may not be applicable depending on how your installer has programmed the fire alarm operations on your system Ask your installer for more information regarding your system s operation 7 13 14 Household Fire Safety Audit Most fires occur in the home To minimize this danger we recommend that a household fire safety audit be conducted and a fire escape plan be developed 1 Are all electrical appliances and outlets in a safe condition Check for frayed cords overloaded lighting circuits etc If you are uncertain about the condition of your electrical appliances or household service have a professional evaluate these units 2 Are all flammable liquids stored safely in closed containers in a well ventilated cool area Cleaning with flammable liquids should be avoided 3 Are fire hazardous materials matches well out of reach of children 4 Are furnaces and wood burning appliances properly installed clean and in good working order Have a professional evaluate these appliances Fire Escape Planning There is often very little time between the detection of a fire and the time it becomes deadly It is thus very important that a family escape plan be developed and rehearsed 1 Every family mem
28. o next function or item of information Press the keys on the number pad as prompted by the LCD display to view alarms or troubles to arm and disarm the system and to bypass zones To exit a function and return to the Ready state press To select a function press gt Important Note Test system weekly and have any system trouble conditions corrected by your alarm installer 10 Zone Bypassing The zone bypassing function is used when access is needed to part of the protected area while the system is armed Zones which are temporarily out of service due to damaged wiring or contacts may be bypassed to allow system arming until repairs can be made Bypassed zones will not cause an alarm Zones cannot be bypassed once the system is armed Bypassed zones are automatically cancelled each time the system is disarmed and must be reapplied before the next arming NOTE For security reasons your installer may program the system to prevent you from bypassing certain zones Bypassing zones reduces your security protection If you are bypassing a zone due to damaged wiring or contacts please call a service technician immediately so that the problem can be resolved and your system returned to proper working order Make sure that no zones are unintentionally bypassed when arming your system To bypass zones from an LED keypad Start with the system in the Ready state Enter 1 Zone s to be bypassed Enter the zone s as
29. ombination of devices subject only to the requirement that the sum of the Ringer Equivalence Number of all the devices does not exceed 5 The REN of this unit is 0 1 AVIS L tiquette de l Industrie Canada identifie le mat riel homologu Cette tiquette certifie que le mat riel est conforme a certaines normes de protection d exploitation et de s curit des r seaux de t lecommunications Industrie Canada n assure toutefois pas que le mat riel fonctionnera la satisfaction de l utilisateur Avant d installer ce mat riel utilisateur doit s assurer qu il est permis de le raccorder aux installations de l entreprise locale de t l ecommunication Le materiel doit galement tre install en suivant une m thode accept e de raccordement L abonn ne doit pas oublier qu il est possible que la conformit aux conditions nonc es ci dessus n emp chent pas la d gradation du service dans certaines situations Les r parations de mat riel homologu doivent tre effectu es par un centre d entretien canadien autoris d sign par le fournisseur La compagnie de t l communications peut demander l utilisateur de d brancher un appareil a la suite de r parations ou de modifications effectu es par utilisateur ou a cause de mauvais fonctionnement Pour sa propre protection utilisateur doit s assurer que tous les fils de mise a la terre de la source d nergie lectrique les lignes t l
30. ons in this manual Emergency Keys All Keypads PC5508Z LCD5500Z Press both Keys for two seconds to send a FIRE transmission Press both A Keys for two seconds to send an AUXILIARY transmission Press both Keys for two seconds to send a PANIC transmission PC1555RKZ Press the F key for two seconds to send a FIRE transmission Press the A key for two seconds to send an AUXILIARY transmission Press the P key for two seconds to send a PANIC transmission IMPORTANT NOTE All Keypads The Fire Auxiliary and Panic keys will NOT function unless programmed by the installer If these keys are in service and the installer has enabled audible feedback holding down the key for two seconds will cause the keypad sounder to beep indicating that the input has been accepted and transmission is underway PC5508Z LED Keypad Memory Bypass Fire Program Ready Armed Trouble LCD5500Z Keypad Ready Armed Trouble E 4 W X X iaa Rorin use formus EKLE Nal Nl N aa TEST SYSTEM WEEKLY Refer to Instruction Manual for testing instructions Memory Light Upon disarming if an alarm has occurred while the system was armed the Memory light will turn ON See Disarming the System on page 5 Bypass Light If the Bypass light is ON one or more zones are bypassed See Zone Bypassing on page 10 Fire Light If the Fire light is ON a fire alarm has occurred
31. ors Enter Cade ta When this message appears use the arrow lt gt keys to verify that the system is firm System lt gt Clear of troubles and that no zones are bypassed unintentionally see Viewing Trouble Conditions on page 11 and Zone Bypassing on page 10 Enter Code to If this display is showing the system is in the Ready state and may be fully armed Arm System To arm the system enter your access code Exit Delay in Once the correct access code has been entered the display will be as shown The panel will provide an exit delay period also indicated by keypad beeps for you to exit the premises without causing an alarm Exit through the door indicated by your installer as the Exit Entry door Progres Enter Code to This message will be displayed once the exit delay expires and the system is fully Disarm System armed 4 WARHIHG If this message appears be aware of which zones are bypassed and why see Bypass Active Zone Bypassing on page 10 NOTE If you arm the system with a zone bypassed or with a trouble present your security protection is reduced Alternate Arming Methods Away Arming Arming the system in the Away mode will have all interior zones and perimeter zones active If motion is detected in the interior zones or if one of the perimeter zones is violated the alarm sequence will begin To arm in the Away mode enter your access code and exit
32. otherwise indicated by your installer Enter digits O through 9 only Press to return to the Ready state Be sure to record your new Master Code on the System Information page in this booklet NOTE We recommend that the factory default or obvious codes such as 1111 or 1234 not be used Additional Codes Up to 32 additional access codes 01 through 32 may be programmed To program a new code Enter 5 Master Code code number 01 to 32 new access code The code number is a double digit from 01 to 32 Access codes must be four digits unless otherwise indicated by your installer Enter digits O through 9 only Press to return to the Ready state If an access code already exists for the code number you have selected it will be replaced by the new code Be sure to record your new code s on the System Information page in this book To erase a code Enter 5 Master Code code number 01 to 32 Press to return to the Ready state The Master code cannot be erased Programming codes from an LCD Keypad Master Code Press the key to enter the function list Scroll lt gt to Press Cki for lt 2 Access Codes Enter Master Access Code Ceo to Edit User Code 40F Enter Mew Cocke 1234 x Cty to Edit User Code 40P Press 5 or x The display will read Enter your current Master Code The display will read 40P repre
33. phoniques et les canalisations d eau m talliques s il y en a sont raccord s ensemble Cette pr caution est particuli rement importante dans les r gions rurales AVERTISSEMENT L utilisateur ne doit pas tenter de faire ces raccordements lui m me il doit avoir recours un service d inspection des installations lectriques ou a un lectricien selon le cas AVIS L indice d quivalence de la sonnerie IES assign a chaque dispositif terminal indique le nombre maximal de terminaux qui peuvent tre raccord s a une interface La terminaison d une interface t l phonique peut consister en une combinaison de quelques dispositifs la seule condition que la somme d indices d quivalence de la sonnerie de tous les dispositifs n exc de pas 5 L indice d quivalence de la sonnerie IES de ce produit est 0 1 FCC COMPLIANCE STATEMENT CAUTION Changes or modifications not expressly approved by Digital Security Controls Ltd could void your authority to use this equipment This equipment has been tested and found to comply with the limits for a Class B digital device pursuantto Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if notinstalled and used in accordance with the instructions may cause harmful interference to radio communications
34. rotective operational and safety requirements Industry Canada does not guarantee the equipment will operate to the user s satisfaction Before installing this equipment users should ensure that it is permissible to be connected to the facilities of the local telecommunications company The equipment must also be installed using an acceptable method of connection The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier Any repairs or alterations made by the user to this equipment or equipment malfunctions may give the telecommunications company cause to request the user to disconnect the equipment User should ensure for their own protection that the electrical ground connections of the power utility telephone lines and internal metallic water pipe system if present are connected together This precaution may be particularly important in rural areas CAUTION Users should not attempt to make such connections themselves but should contact the appropriate electric inspection authority or electrician as appropriate NOTICE The Ringer Equivalence Number REN assigned to each terminal device provides an indication of the maximum number of terminals allowed to be connected to a telephone interface The termination on an interface may consist of any c
35. sents the Master Code Press the key to indicate that you wish to program the Master Code The display will read Enter the new Master Code The Master Code must be four digits unless otherwise indicated by your installer Enter digits O through 9 only Once the new code is entered the keypad will beep 3 times and the display will read lt gt Press to exit the code programming function Be sure to record your new Master Code on the System Information page in this booklet NOTE We recommend that the factory default Master Code 1234 not be used Additional Access Codes To erase add or change a user code press to enter the functions list Use the arrow lt gt keys to scroll to the following message Fress Oho for o gt Access Codes Ce to Edit Uzer Dode GIF Enter Mew Cocke 1234 lt LET to Edit User Code iF Press Display will read Enter the Master Code Display will read Use the scroll keys lt gt to find the access code indicated by O2P to 32P you wish to add change or delete Press the key to select the code you wish to alter The display will read To add or change a code enter the new code Access codes must be four digits unless otherwise indicated by your installer Enter digits O through 9 only To delete an access code enter x Once the 4 digit code or x has been enter
36. st enter your security code and disarm the system Arming Without Entry Delay If you wish to arm your system without the entry delay enter 9 then your access code The Armed light will flash as a reminder that the system is armed and has no entry delay An entry through any zone programmed as a delay zone will create an instant alarm Quick Arm When the Quick Arm feature is enabled the system may be armed by simply pressing 0 instead of your access code Please note that pressing 0 will only allow you to arm the system to disarm you must enter a valid access code Your installer will inform you if the Quick Arm feature has been enabled on your system Quick Exit When the Quick Exit feature is enabled pressing 0 while the system is armed will provide a two minute window for you to exit the premises During this time you may only open and close the designated Entry Exit door once Once the door is closed the panel will end the two minute quick exit delay If the door is opened again or if the door is not closed after two minutes or if another zone is opened the panel will begin the entry delay Your installer will inform you if the Quick Exit feature has been enabled on your system Disarming the System Disarming from an LED Keypad Enter the premises through a designated Exit Entry door entering by any other door will sound an immediate alarm As soon as the Exit Entry door is opened the keypad will beep to in
37. the premises through a designated Exit Entry door The system will recognise that occupants have left the premises Once the exit delay expires the system will be fully armed Audible Exit Fault In an attempt to reduce false alarms the Audible Exit Fault is designed to notify you of an improper exit when arming the system in the Away mode In the event that you fail to exit the premises during the allotted exit delay period or if you do not securely close the Exit Entry door the system will notify you that it was improperly armed in two ways the keypad will emit one continuous beep and the bell or siren will sound If this occurs you must re enter the premises enter your access code to disarm the system and then follow the arming procedure again making sure to exit the premises in the proper fashion Stay Arming This feature if enabled by your installer will allow you to arm the perimeter zones while leaving the interior zones inactive so that you can remain on the premises while the system is armed When you enter your security code to arm the system and do not exit the premises through a designated Exit Entry door the system will arm in the Stay mode automatically bypassing the interior zones The interior zones can be reactivated at any time by entering 1 at any keypad If you reactivate the interior zones be sure to only inhabit areas not covered by motion detectors To access areas protected by motion sensors you mu

Download Pdf Manuals

image

Related Search

Related Contents

Samsung BD-F6700  Manual usuario  Wireless Base Stations Manual  Prêt et location d`instruments - Communauté d`Agglomération Grand  e+p C 1200  user manual Geratherm chlamydia check  Manual de instrucciones  让公共视讯更完美! LED室内屏幕序列------高精度  iridium IntelliDOCK 9555 Installation & User Manual - E-SAT  Philips 42PFL5432D 42" LCD Full HD 1080p digital widescreen flat TV  