Home
RJL Bioelectrical Impedance Analyzers (BIA)
Contents
1. i Measuring amp Managing Healthy Living 7 Safe Reliable and Accurate r Body Composition RJL Bioelectrical Impedance Analyzers BIA Quantum Series Product Catalog October 2010 About RJL Systems Which Quantum is right for you Quantum II Quantum X Quantum IV Quantum III Quantum Desktop BC Software Version 2 1 Accessories amp Supplies 10 11 o Nl AUA RA Ww WY RJLS ystems Inc 33939 Harper Avenue Clinton Township Michigan 48035 USA Voice 1 800 528 4513 Fax 1 586 790 0205 www rjlsystems com Founder of the BIA industry amp Providing BIA instruments amp solutions for over 30 years RJLS ystems 33939 Harper Ave Clinton Township Michigan 48035 US A 800 528 4513 Measuring amp Managing Healthy Living F Safe Reliable and Accurate r ABOUT US RJL Systems gt HISTORY In 1979 RJL Systems developed the use of bioelectrical impedance analysis BIA to assess human body composition for the United States Navy and was the first company to engineer and manufacture BIA analyzers RJL analyzers were introduced to the commercial marketplace in 1981 gt QUALITY RJL analyzers provide BIA measurements for users around the world they are recognized as research quality because of their reputation for accuracy and reliability Our instruments are considered the Gold Standard of the BIA testing industry gt PATENTS RJL has regist
2. QUANTUM IT BIA Analyzer Instrument Kit Includes Quantum II Analyzer Flexible Subject Cables Stay Fresh Pack of Electrodes 200 ct enough for 50 tests Test Resistor BC Software amp User Manual Carrying Case watertight airtight dustproof Instrument User Manual 9 Volt Battery SSS VALSA 1 990 00 with 1 year warranty Product Overview The Quantum II is an ideal choice for users who desire a BIA Analyzer that is compact and portable The combined key features of the Quantum II and the accompanying BC software provide an easy to use accurate and affordable instrument for revealing and monitoring changes in the composition of the human body BC Software After testing with the Quantum II Analyzer the measurements are entered into the BC software which performs the body composition analysis The end results can provide guidance for an individual to improve their body composition using the diet and exercise wizard in BC Health Professionals Many professionals in the health fitness and nutrition fields know this instrument is very useful as scale weight alone does not provide enough information to manage an overall health plan for individuals With the Quantum I they have the ability to know when fat fat free mass and fluids are lost or gained when working with patients and clients to improve body composition in relation to health and fitness management Institutional Researchers For researchers the Quantum II
3. Large 4 5 digit display Automatic off When no subject is connected 5 seconds When subject is disconnected instant off When a subject is connected 5 minutes Advanced power management with auto shut off extending battery life Subject is isolated fromall electronic components with passive isolation technology Constant current accuracy Nominal 400 microamp max at 50 KHz 1 50 Khz sinusoidal extremely stable phase sensitive Regulation better than 0 1 electronics Range 0 to 10 000 ohms resistive or capacitive Measures resistance and capacitive reactance directly Resi 7 esistance accuracy Membrane push button switches for touch and run Nominal 1 0 ohm operation Range 0 1000 ohms Resolution 0 1 ohm Detects when subject is connected and instantly detect when subject is disconnected Reactance Accuracy Nominal 1 0 ohm Range 0 1000 ohms Resolution 0 1 ohms RJLS ystems 33939 Harper Ave Clinton Township Michigan 48035 US A 800 528 4513 rt NEW QUANTUM IV BIA Analyzer Instrument Kit Includes Quantum IV Analyzer Flexible Subject Cables Stay Fresh Pack of Electrodes 400 ct enough for 100 tests Test Resistor USB Cable 6 ft BC Software amp User Manual Carrying Case watertight airtight dustproof 12 Volt Universal Battery Charger Instrument User Manual Internal Rechargeable Lithium Ion batteries ANN NNN 2 490 00 with 1 year warranty Product Overview T
4. Americans Obese BMI gt 30 African American Obese Athletic HIV BIA 103 Provided for historical purposes only All Body Types BMI adjustable Instrument Requirements MINIMUM Windows PC with 133 MHz processor or faster Windows 95 98 ME NT 2000 XP Vista 800 x 600 screen resolution 30 MB disk space 32 MB memory RECOMMENDED Windows PC with 300 MHz processor or faster Windows 2000 XP Vista 1024 x 768 screen resolution 30 MB disk space greater than 64 MB memory RJLS ystems 33939 Harper Ave Clinton Township Michigan 48035 US A 800 528 4513 IL SVS TEES His vie ree SR 7 AU pirate ee 100 Electrode Package 25 BIA tests 1 10 per test Shipped in a sealed pack with 10 sheets of 10 electrodes each The electrodes expiration date is printed on the back of each package 27 50 pack Stay Fresh 200 Electrode Pack 50 BIA tests 0 90 per test Shipped in a re usable plastic box with two electrode packages Keeps electrodes from drying out once the package is opened 45 00 pack Stay Fresh 500 Electrode Box 125 BIA tests 0 80 per test Contains one Stay Fresh pack and three additional electrode packages The most economical way to buy electrodes when doing many BIA tests 100 00 box Electrode Placement Card Flexible laminated electrode placement card that educates new BIA users how to place electrodes on the hand and foot to assure
5. Specifications Based on the Quantum IV design and Constant current accuracy specifications with additional features Nominal 400 microamp max at 50 KHz 1 eres P Regulation better than 0 1 Large easy to read keypad for entering subject informatior 6 PN ee z 1 uP Fs Range 0 to 10 000 ohms resistive or capacitive Thermal printer that prints body composition reportson4 paper within seconds Resistance accuracy Nominal 1 0 ohm Secure Bluetooth RF communications for printing graphiq Range 0 1000 ohms reports on aPC up to 300 ft Resolution 0 1 ohm Hundreds ofsubject records can be save in internal non Reactance Accuracy volatile memory and retrieved with a PC Nominal 1 0 ohm Real time clock and calendar that use the internal Lithiun Range 0 1000 ohms Ion batteries Resolution 0 1 ohm RJLS ystems 33939 Harper Ave Clinton Township Michigan 48035 US A 800 528 4513 QUANTUM DESKTOP BIA Analyzer Instrument Kit Includes Quantum Desktop Analyzer Lemo Subject Cables Stay Fresh Pack of Electrodes BC Software amp User Manual Datalogger Software amp User Manual Mini Thermal Printer One Roll Thermal Paper Portable PS 2 keyboard Carrying Case watertight airtight dustproof Instrument User Manual KASSI KARAS 4 990 00 with 1 year warranty Product Overview The Quantum Desktop instrument is designed to be a portable instrument It can be used to analyze human body
6. composition or perform BIA analysis on biological materials such as animals fish plants or specific segments of the human body i e chest muscle groups and organs 1 When used for measuring human body composition it can retrieve resistance and reactance values from the subject perform all of the body composition calculations and print a basic report using the attached thermal printer Data entry subject ID height weight etc is accomplished with the included keyboard Its accuracy record storage instrument and printing capability reduce errors in data entry It is built to specifications necessary to comply with peer review literature guidelines and traditional BIA instruments BC Software This instrument can temporarily store patient records then transferred later to the BC Software for historical tracking and printing of more detailed reports It can be directly connected to a PC and interact with BC Software Key Features The desktop also measures resistance and reactance as real time events Real time BIA records a steady stream of data with adjustable sampling rates from one millisecond to several hours between samples It can save up to 15 000 records with individual time stamps in its internal non volatile memory that can be retrieved at a later time The Data Logger software allows the instrument to be used as an impedance plethysmograph recording real time changes in resistance and reactance and displaying them on the s
7. is designed to provide bioelectrical resistance and reactance measurements in a variety of populations Extremely small changes in body composition can be illustrated due to the instrument s exceptional accuracy and repeatability The results of testing with the Quantum II Instrument can provide the user with a method to monitor and historically track body composition changes Features of the Quantum IT Measures resistance and capacitive reactance directly 50 KHz sinusoidal extremely stable phase sensitive electronics Subject is isolated fromall electronic components with RJL instruments passive isolation technology Runs on a single 9 volt alkaline battery Large 3 5 digit display Membrane push button switches for touch and run Operation Advanced power management with auto shut off extending battery life Detects when the subject is connected and instantly shuts off when the subject is disconnected RJLS ystems 33939 Harper Ave Clint Specifications Automatic off When no subject is connected 5 seconds When subject is disconnected instant off When a subject is connected 5 minutes Constant current accuracy Nominal 400 microamp max at 50 KHz 1 Regulation better than 0 1 Range 0 to 10 000 ohms resistive or capacitive Resistance accuracy Nominal 1 0 ohm Range 0 1000 ohms Resolution ITohm Reactance Accuracy Nominal 1 0 ohm Range 0 1000 ohm ownship Michigan 48035 US A 8
8. 00 528 4513 4 QUANTUM X BIA Analyzer Instrument Kit Includes v Quantum X Analyzer v New Flexible Subject Cables Stay Fresh Pack of Electrodes 200 ct enough for 50 tests v Test Resistor v BC Software amp User Manual v Carrying Case watertight airtight dustproof v Instrument User Manual v 9 Volt Battery 2 490 00 with 1 year warranty Product Overview The Quantum X has the same compact size portability and range 0 to 1000 ohms as the Quantum II with a significant technical difference the Quantum X has 10 times the resolution 1 of the Quantum II Health Professionals This Analyzer is used by health professionals who want to use BIA to analyze human body composition as a whole body measurement In addition the Quantum X is also capable of performing BIA analysis on subjects such as domestic and wild animals and fish These measurements may yield resistances of less than 100 ohms and require increased resolution Institutional Researchers The Quantum X is an ideal instrument for biologists and other researchers who need to measure and collect BIA data with a higher resolution Measurements with the Quantum X are quick repeatable and accurate Its portability gives researchers the option to use it in the field in all different environments 1 The Quantum X has 0 1 ohms of resolution resistance and reactance and the Quantum II has 1 0 ohms of resolution Features of the Quantum X Specifications
9. 1 Features of BC e Estimates body composition and other values FAT TBW BMR FFM ICW DEE BMI ECW Phase Angle Impedance e Historical graphs and reports allow tracking changes over time e Provides sample exercises and diet plan to help promote a healthy lifestyle Included FREE with every BIA instrument or 250 00 if purchased separately BC software is ideal for the health care professionals monitoring and recording changes in body composition Scale weight alone does not provide enough information to help create customized healthy weight management programs for individuals After testing with a RJL BIA Analyzer the measurements are entered into the BC software which performs the body composition analysis The results can provide suggestions for effective lifestyle changes to improve body composition by using the diet and exercise wizard included in the software Body composition changes can be easily monitored over time with historical graphic and or numeric reporting BC is also able to import patient information from databases created by RJL instruments previous body composition software packages and some more advanced body composition analyzers BC 2 1 provides numerous sets of prediction equations for estimating body composition including NHANES III General Population Pediatric Ages 9 14 New Pediatric Ages 4 19 Also validated for obese children Mexican Adults Male amp Female Native
10. creen Its use is intended for investigational purposes only 1 RJL Systems only provides software for estimating human body composition from a whole body measurement Users wishing to do segmentalbody composition analy sis or study nonhuman organisms must acquire software or equations elsewhere BC is packaged with the Quantum Desktop Features of the Quantum Desktop Operates as a standalone real time BIA instrument that can store 15 000 time stamped records in non volatile memory 0 1 ohms resolution resistance and reactance Can be safely connected to a PC and subject at the same time Data sampling from 1 millisecond to hours BC software can directly read resistance and reactance values fromthe subject Portable PS 2 keyboard included for set up Internal battery operated UPS uninterrupted powa supply for 4 hours to assure no record losses during a power failure RJLS ystems 33939 Harper Ave Clint Specifications Isolation Barrier Nominal 10 000 megohmat 1000 VDC Subject leads to analog ground Constant current accuracy Nominal 400 microamp max at 50 KHz 1 Regulation better than 0 1 Range 0 to 10 000 ohms resistive or capacitive Resistance accuracy Nominal 1 0 ohm Range 0 1000 ohms Resolution 0 1 ohm Reactance Accuracy Nominal 1 0 ohm Range 0 1000 ohms Resolution 0 1 ohm ownship Michigan 48035 US A 800 528 4513 BC Body Composition Software Version 2
11. dy composition from whole body measurements The Quantum II Analyzer is one of RJL s Quantum lines of accurate and reliable BIA instruments Self contained and portable the Quantum III was designed to give the user a variety of technical options as to how data is recorded stored viewed and printed Product Features Despite its compact size and portability it is a selfcontained instrument of measuring and recording BIA data It does not require a PC to record and store information hundreds of time stamped records can be stored in its non volatile internal memory The large keypad makes it easy to enter subject information and create a complete body composition record and report The internal Lithium Ion batteries last for approximately 3 hours of continuous use and can be safely fully recharged within a few hours The user has two options to print body composition reports 1 the portable thermal printer or 2 use the wireless radio frequency link for printing graphic reports on a PC within a 300 ft range The wireless link complies with most worldwide regulatory standards BC Software Human body composition data can also be saved in the BC Software database on a PC for further analysis and historical tracking of individuals The Quantum III is extremely accurate and fast it can perform a complete body composition analysis and generate a printout or send data to a PC in a matter of minutes Features of the Quantum HI Specifications
12. e USB port serves serveral functions The most important is downloading or upgrading the firmware program in the internal micro controller As new features are developed at RJL Systems for the Quantum IV they can be transferred to instruments by the user thereby eliminating obsolescence Environment Temperature The Quantum IV has design features that greatly reduce the effects of hot and cold environment temperatures There is less than a one percent change of full scale resistance and reactance from 20 to 60 degrees centigrade Battery Charger Included with the Quantum IV is a 12 volt universal world wide 120 240 VAC battery charger Rear panel The Quantum IV back panel is labeled with CE and other compliant symbols for acceptance into most worldwide regulatory bodies These symbols are permanently engraved into the enclosure RJLS ystems 33939 Harper Ave Clinton Township Michigan 48035 US A 800 528 4513 QUANTUM III BIA Analyzer Instrument Kit Includes Stand Alone Quantum III Analyzer Mini Thermal Printer Wireless Radio Frequency Communications Serial and USB Cables 6 Pin Subject Cables Stay Fresh Electrode Pack Enough for 50 tests Test Resistor BC Software and User Manual Carrying Case watertight airtight dustproof Internal Rechargeable Lithium Ion batteries Instrument user manual LN NNN A 3 990 00 with 1 year warranty Product Overview The Quantum III is used to assess human bo
13. ered U S patents on our instruments trademarks and copyrights on our software and papers Customers are buying products ftom the company that develops engineers and manufactures the Analyzers gt FDA CLEARANCES Quantum Analyzers have FDA clearance as a Class II medical device for safe use on the human body to collect BIA data RJL is registered with the FDA as a Medical Device Manufacturer Registration No 1831675 gt ISO STANDARD As of May 29 2008 RJL Systems was registered as an ISO 9001 2000 company and is ISO 13485 compliant gt QUALITY CONTROL RJL instruments go through a rigorous testing calibration and inspection process that complies with ISO standards Conformity of products and services to International Standards provides assurance about overall product quality safety reliability and accuracy gt CUSTOMER SUPPORT Any questions or customer support needed regarding our products will be handled by the professionals who designed and built the analyzers and the related software gt OEM The Company s 30 years of engineering expertise and knowledge in BIA science make it uniquely qualified to provide custom made instruments of any size or scope gt WEBSITE RJL Systems revised its website to provide in depth information on BIA science and showcase the range of its products If you sign up for the e mail newsletter via website you will receive information on interesting new developments in the field o
14. f BIA science and or RJL products gt WARRANTY TECHNICAL SUPPORT All RJL products come with a warranty and continued technical and product support RJLS ystems 33939 Harper Ave Clinton Township Michigan 48035 US A I 800 528 4513 2 Which RJL QUANTUM BIA Analyzer is right for you Quantum Analyzers Comparison Chart Applications wntenumanonaycomposton J scsonware mvc Monitor impedance values in real time Features External portable printer Internal record storage 1 ar wieessconmuncsinege ing ecttime sia win teratsorage ons mooersorwaremesea saneyomanuas Standard 9 Standard 9 Battery type Volt Volt Nickel Metal Lithium Ion Lead Acid 1 The Quantum III can store 50 complete subject records The Quantum IV stores a single resistance and reactance record When the Quantum IV segmental option is used 13 zones of resistance and reactance data are stored 26 records The Quantum Desktop can store 500 complete records or save 12 000 real time resistance and reactance data points with time stamps 2 The fish option of the Quantum III is designed to record hundreds of individual fish records while used at sea These records can then be downloaded via the USB port toa PC for analysis 3 Resolution accuracy is greater with lower Ohm level i e 0 1 Q provides higher measurment accuracy RJLS ystems 33939 Harper Ave Clinton Township Michigan 48035 US A 800 528 4513
15. he Quantum IV is an advanced BIA Analyzer with features and specifications that are not available in traditional RJL products It is extremely accurate and easy to use with an enclosure that has a comfortable curved ergonomic design The internal lithium ion rechargeable batteries can be recharged using either the included AC adapter or an optional foldable solar panel Key Features The Quantum IV precisely measures resistance and reactance at 50 KHz Many new features such as a four line bright back lit LCD isolated USB port and micro controller calibration are standard The firmware of the Quantum IV can easily be upgraded from a PC connected to the Internet The versatile micro controller and circuit design allow it to be tailored to specific customer requests with minimal effort such as language locale German Italian and Spanish BC Software BC software is included with the Quantum IV Resistance and reactance data from the instrument can be either manually entered into BC or automatically retrieved safely using the USP port cable while connected to a human subject Specifications Same as the Quantum X with additional features Lithium Ion Batteries Two 800 milliamp hour rechargable lithium ion batteries 4 Line LCD Display What is displayed The first two lines are the measured resistance and reactance values with 0 1 ohms ofresolution Phase angle and impedance are also displayed on the bottom two lines USB Communications Th
16. repeatable measurements The back of the card has BIA do s and don ts Free when requested RJLS ystems 33939 Harper Ave Clinton Township Michigan 48035 US A 800 528 4513 10 JL SYSTEMS BIA Instruments Accessories amp Supplies Din Lemo Subject Cable 6 0 foot subject cable for the Quantum II Quantum X and Quantum Desktop BIA instruments Also available in custom configurations 110 00 cable Precision BIA Test Resistor 500 0 Ohm resistor calibrated to 0 1 percent with zero capacitance Used to test and maintain all BIA instruments from most manufactures Free when requested Thermal Printer Paper Roll for printers e Citizen PD 24 e Seiko DPU 414 These printers are included with the Quantum III and Quantum Desktop BIA instruments 5 00 roll Please note RJL Systems always keeps our warehouse fully stocked so our customers get what they need when they need it If you need assistance selecting the right products or need urgent delivery service please feel free to contact us by using our on line website or call RJL Systems Inc 33939 Harper Avenue Clinton Township Michigan 48035 Voice 1 800 528 4513 Fax 1 586 790 0205 www rjlsystems com RJLS ystems 33939 Harper Ave Clinton Township Michigan 48035 US A 800 528 4513
Download Pdf Manuals
Related Search
Related Contents
Guide d`autocontrôle pour la production et la vente de Knight Spot HBV and IWRM Watershed Modelling User Guide Magnochem Manual de instrucciones de servicio/montaje La géographie des homosexualités, entre éthique, épistémologie et user manual Saeco Saeco HD8751 PCC Blackboard Instructor User Manual Users ManUal GUIDe D`UTIlIsaTIOn ManUal Del UsUarIO Copyright © All rights reserved.