Home
Configuring the Cole-Parmer® Touch Screen Series
Contents
1. 23 C Password Protection Set up 08 24 09 9 17 18 AM A password can be enabled to prevent accidental changes to program settings Unlocking the Date Time 4 taal PS touchscreen requires a password defined by D the user Rudible Rlarms I Display Pump Q Brightness 100 Address 0 co RN Rega Set The Pump Password 07 23 09 9 03 23 AM 2 Pump Password Setting the Password O To set the Password go to the Settings screen Press the Set Password button C Enter your desired password up to 8 digits and OAO press the ACCEPT button gt de Turning the Touchscreen Lock on A Press the Lock button twice to lock the Configuration 10 30 09 10 21 47 AM D MN KDS Glass D Turning the Touchscreen Lock off SYRINGE ETA Press the LOCK button to bring up the Enter the RATES 36 003 ml min C Pump Password screen wa Enter your password and press the ACCEPT TARGET ig o D button m Password O Lock Button N Configuration 10 30 09 10 23 12 AM NOTE f you forget your password BZ contact Cole Parmer Technical Support M at 800 323 4340 UE ass SYRINGE 10 001 RATES 36 003 ml min EH rJ DELAY Volume MEN oO E NY Cole Parmer phone 8 00 3 2 3 43 40 fax 847 247 2929 Cole Parmer Touch Screen Series Syringe Pump User s Manual email info coleparmer com web www coleparmer com Publication 5607 009 REV B Configuring the Cole Parmer Touch Screen Series 24 Setting the Force Limits
2. B ERROR 101 ERROR 102 ERROR 201 ERROR 207 ERROR 210 ERROR 211 ERROR 212 ERROR 213 ERROR 214 ERROR 215 ERROR 216 EEz Cole Parmer Delivering Solutions You Trust_ Run Mode Errors Set up Errors Program Errors Critical Errors ERROR 202 ERROR 203 ERROR 204 ERROR 205 ERROR 206 ERROR 208 ERROR 209 Operating the Cole Parmer Touch Screen Series ERROR CODES NOTE Error and Alarm text are shown in a yellow box whereas Notice Confirm and Verified are shown in a green box Error 1XX Error 2XX Error 3XX Error 4XX Run Mode Errors Power to the pump was lost The A D convertor is not working Set up Errors Display brightness percentage is out of range enter a value from 10 to 100 Near end of run alarm percentage is out of range enter a value from 1 to 100 Force percentage is out of range enter a value from 1 to 100 Pump address is out of range enter a value from O to 99 Pump to pump address is out of range enter a value from 1 to 99 Custom syringe volume is out of range enter a value from 0 05 ul to 250 ml Custom syringe diameter is out of range enter a value from 0 1 mm to 99 mm Date is out of range enter a month from l to 12 a day from 1 to 31 and a year from 08 to 37 Time is out of range enter the hour from 1 to 12 or O to 23 and min and sec from O to 59 Infuse Rate is out of range Withdraw rate is out of
3. O C O gt e C C lt D D C 3 Select the Virtual Comm Port from the Connect using drop down list Click OK If the Virtual Comm Port is not known use Device Manager to find it Instructions on setting up the Virtual CommPort Driver 6 Choose ASCII Setup and select Echo typed characters locally then click OK to complete 91 19 are supplied in Appendix E the setup ASCII Setup 7l ES Connect To ASCII Sending Send line ends wath ine feeds Iv Echo typed characters locally Line delay 0 mikseconds Character delay o milliseconds S Syringe Pump Enter details for the phone number that you want to dial Country region United States 1 Area code Connect using A y ASCII Receiving Append line feeds to incoming line ends Force incoming data to 7 bit ASCII v Wrap lines that exceed terminal width NOTE To determine the proper comport BZ in your PCs Systems Properties screen m under the Hardware tab select 2 po als o nore connected correctly in Hyperterminal s main CONS Wen iS een window press Enter a should appear If o ela not connected properly close Hyperterminal turn off the pump unplug then re plug the to this i thesis RE aan G USB cable and re open Hyperterminal Y phone 8 0 0 3 2 3 A3 4 0 fax 847 247 2929 Cole Parmer Touch Screen Series Syringe Pump User s Manual email info coleparmer com
4. Delete Program Step showing confirmation message on the screen 2 Highlight select with a single touch the Step for which you want to change the order 4 To confirm the deletion choose the Delete Step 3 Choose the Move Step Up or Move Step Down button again The Step is removed and you are button as required to move the Step into the returned to the Program Steps Summary screen position that you want it executed NOTE f there are Program Commands BZ e g Go To that link to the Step moving Steps can result in unexpected results as the Command may be linked to the Step number You should always recheck all Program C o i O m 3 D O C O e C C lt D D C Defining Program Step Parameters This section of the User Guide describes each of the available functions available for use in Cole Parmer Touch Screen Series Existing and User Defined Programs The information in this section is designed to help you set the individual parameter values in each of the Program Step options and to properly use the Advanced Options 91 19 Commands after adding deleting or moving Steps in a previously created Program commands Step Definition 08 24 09 9 49 53 AM The information that follows is organized into two sections Step 1 Delay Program 5 Seconds 1_PROGRAM Pump Operation Profiles Step Ramp _ 3 295 ml min 3 335 nimi aaa Advanced Options Commands and I O 3 295
5. 6 Push the Syringe Holder s Retaining Bracket 3 tight against the barrel flanges and tighten into place using the two T Knobs 7 6 10 Multi Rack 7 Tighten the Anti Syphon Bar 4 using the three thumb screws If using the 6 10 rack flip the Plunger Holder back into place 8 and secure by tightening thumb screws 8 Lower or replace the Clamp Bar 6 and tighten thumb screw until Clamp Bar is firm against syringe s 44 Cole Farmer phone 8 0 0 3 2 3 4 3 4 0 fax 847 247 2929 Cole Parmer Touch Screen Series Syringe Pump User s Manual email infoOcoleparmer com web www coleparmer com Publication 5607 009 REV B Appendices 73 Mounting a Micro Liter Multi Rack Continued Pusher Block T Knob 2 2400 231 2402 014 Spring Washer 2 5110 003 te Anti Syphon Bracket 2400 242 Micro Anti Syphon Bracket 2400 289 Pusher Block Assembly 1 Remove the Pusher Blocks Anti Syphon Bracket by unscrewing and removing the T Knobs 2 and Spring Washers 2 2 Attach Micro Anti Syphon Bracket using T Knobs 2 and Spring Washers 2 A Cole Parmer phone 8 00 JJ 2 3 43 A0 fax 847 247 2929 Cole Parmer Touch Screen Series Syringe Pump User s Manual Publication 5607 009 REV B email infoOcoleparmer com web www coleparmer com Appendices 74 Mounting a Micro liter Multi Rack Assy Clamp Bar Micro Rack 2400 290 Stand off 2 5015 035 T Knob 12 m Spring Washer 2 5100 059 5110 003 J Flange Reta
6. Argument errors Argument errors are displayed when a command argument is unrecognized or out of range The argument in question will be displayed except in the case of missing arguments The argument error has the following format lt f gt Argument error bad argument lt cr gt lt f gt lt sp gt lt sp gt lt sp gt error message lt cr gt lt lf gt lt prompt gt System commands ADDRESS Sets or displays the pump address Valid range is O to 99 Command format address 0 99 Query response lt f gt Pump address is lt cr gt lt f gt lt prompt gt NOTE Pumps with an address of O are BZ masters and pumps with an address between 1 and 99 are slaves BAUD Sets or displays the RS232 port baud rate Valid baud rates are 9600 19200 38400 57600 115200 128000 230400 256000 460800 and 921600 Note that some computers may not be able to handle baud rates above 115200 Command format baud 9600 19200 38400 57600 115200 128000 230400 256000 460800 921600 Query response lt lf gt baud lt cr gt lt f gt lt prompt gt phone 800 323 4340 fox 847 247 2929 email infoOcoleparmer com web www coleparmer com 58 NOTE If this command is entered via RS232 the prompt is displayed at the previous baud rate and then the baud rate is changed e CATALOG Displays a catalog of methods stored in the pump Command format cat Query respon
7. Start Withdraw Defines the falling edge signal to trigger a refill withdraw action Valve The pump automatically sends signals via pin 8 to activate de activate when the pump changes direction Use this feature to break that feature and gain control of valve operation Valve On Activates the valve Valve Off De Activates the valve Valve Auto Returns pump to automatic valve control mode phone 800 323 4340 fox 847 247 2929 email infoOcoleparmer com web www coleparmer com 1 e Choose the INS STEP button to access the 49 TO INSERT AN I O OUT TRIGGER COMMAND From the Program Main screen choose Step Definition to enter the Step Definition screen Highlight select once the Program Step that you want the O OUT Trigger to follow a Program Steps Menu screen Choose Advanced Options to enter the Select Advanced Options screen Choose the I O OUT Trigger button to enter the Trigger Step Definition Screen Set your Trigger settings by choosing the appropriate option from the following sub procedures a To send a Trigger signal to an external device via Pin 4 select the Trigger 1 button To send a Trigger signal via Pin 5 select the Trigger 2 button selection will highlight in blue Then select whether the signal will be High or Low by selecting the appropriate button selection will highlight in white b To send a trigger signal to an external valve select Valve
8. Then select whether the trigger will actuate Actuated button or close Off button by selecting the appropriate button c To send a synchronization signal to a connected pump select Synchronize Then select whether you want to start an infusion action Start Infuse button or a withdraw action Start Withdraw button by selecting the appropriate button Choose the Accept button to save your changes and return to the Step Definition screen NOTE When using triggers the first step in your program should define the trigger starting level High or Low You may then use the trigger command to change the level as desired for your Program Cole Parmer Touch Screen Series Syringe Pump User s Manual Publication 5607 009 REV B Operating the Cole Parmer Touch Screen Series I O IN Event The I O IN Event command is used to have the pump pause and wait for a signal from an external device or for a manual user input at the touchscreen These external signals are communicated via Pin 2 on the 15 pin I O Connector port Event Input High to Low Input Low to High 08 24 09 1 28 15 PM BACK I ENTR I O IN Event Advanced Options menu The following options are available when setting an I O IN Event command e Input High to Low Sets the pump to wait for a logic low input signal falling edge e Input Low to High Sets the pump to wait for a logic high input signal rising edge User Press Sets the pum
9. To use the h m s option enter your time value in hours minutes and seconds separating each value with a colon You can enter a value up to 99 99 99 8 When your Time entry is correct choose the Accept button to insert the Delay Step in the Program and return to the Step Definition screen 46 Repeat Step The Repeat Command is used to repeat Steps in a procedure a defined number of times To use this Command you will tell the application what Steps you want to Repeat and how many times you want them repeated The Repeat Step command creates a jump back to a specific Step in a Program that executes the defined Step plus all following Steps up to the Repeat command i e it creates a Program loop When defining a Repeat jump in a Program the Command targets the Step sequence position and not the function that currently occupies that position For example if you create a Repeat jump to Step 4 in a Program currently a Ramp Pump Operation Profile and subsequently move a Constant Rate profile into the Step 4 position the Repeat jump will then connect to the Constant Rate operation and not to the Ramp operation TO INSERT A STEP REPEAT SEQUENCE IN A PROGRAM 1 From the Program Main screen choose Step Definition to enter the Step Definition screen 2 Highlight select once the Program Step that you want the repeat step to follow 3 Choose the INS STEP button to access the Program Steps Menu screen
10. a 4 Choose Advanced Options to enter the Set Advanced Options screen 5 Choose Repeat to insert the Repeat Step function into the Program 6 Select the Step s you would like to repeat from by selecting the Step button twice or selecting once and then choosing Accept Repeat from Selection 07 21 09 12 33 45 PM 69 34 nl min 36 mimin 36 ml min bo To BACK I ENTR Advanced Options Repeat Step screen Choosing Repeat brings you to a list ing of the available steps in the Program 7 Enter the number of repeats using the keypad then choose the Accept button to save your change and return to the Step Definition screen NOTE This command creates a loopback to the designated Step in a Program executing the selected e Steps 2 and 3 one additional time phone 800 323 4340 fox 847 247 2929 email infoOcoleparmer com web www coleparmer com Step plus all subsequent Steps up to the point of insertion of the Repeat command For example if the Repeat command is set to repeat Step 2 one time the system will loop back to Step 2 and execute both Cole Parmer Touch Screen Series Syringe Pump User s Manual Publication 5607 009 REV B Operating the Cole Parmer Touch Screen Series 47 Link Program Stop The Link Command is used to insert a link to another The Stop Command is used to instruct the pump to stop stored Program into the operating sequence of a operation This Command can be used in conjunction Program You
11. 009 REV B
12. 1 unm INFUSION TIME 00 00 08 FLOW DIRECTION TIME ELAPSED 00 00 wa UY TIME REMAINING 00 00 03 STATUS INFUSING A TOTAL INF VOLUME 2 969 ml r D E ZZ cJ Cole Parmer phone 8 00 3 2 3 43 40 fax 847 247 2929 Cole Parmer Touch Screen Series Syringe Pump User s Manual email info coleparmer com web www coleparmer com Publication 5607 009 REV B Operating the Cole Parmer Touch Screen Series Custom Program Workflow The following flow diagram describes the use of an Custom Program Select Program Select Syringe Manufacturer amp Size OR Create New Syringe Type Review Program Steps Pump Operation Profiles Enter Pump Operation Profile Parameters Validate Commands and l O Operations The software provides the user with a variety of prompts and warnings to help guide the setup of programs For example if a pump Program incorporates steps that exceed the capacity of the defined syringe the system will prompt you that parameters are outof range The system also prompts users if required values are not entered NOTE The pump will check the validity of e parameters entered for each Step in the Program but will not review the Program in its entirety to verify that it is logical and can be fully executed phone 800 323 4340 fox 847 247 2929 email infoOcoleparmer com web www coleparmer com 30 Cole Parmer Touch Screen Series Syringe Pump User s Manual Publication 5607 009 REV B p
13. 2 3 4 3 4 0 fax 847 247 2929 Cole Parmer Touch Screen Series Syringe Pump User s Manual email infoOcoleparmer com web www coleparmer com Publication 5607 009 REV B oS Cole Parmer SYRINGE LOADING 2 4 r The Standard Cole Parmer Touch Screen Series can accommodate up to two syringes Any type of syringe glass plastic or stainless steel can be used The pump can accommodate from 0 5 ul to 140 ml syringes The syringe barrel clamp should be flipped for syringes smaller than 30 ml For syringes larger the 30 ml the syringe clamp should be used as shown l Squeeze the release tabs 1 and move the pusher block 2 to the approximate length of the syringe 2 Unscrew the bracket clamping knobs 7 8 to loosen the retaining brackets 4 5 on the pusher block 2 and the Syringe holder block 3 3 Unscrew the syringe barrel clamp by unscrewing the syringe barrel clamp knob 6 4 Place the syringe on the syringe holder block 3 Ensure the barrel flange is with in the syringe holder s block s retaining bracket 5 and the plunger flange is gt 30 cc Sus phone 800 323 4340 tax 847 247 e mail infoOcoleparmer com web Product Overview 14 in the pusher blocks retaining bracket Screw down the syringe clamp knob 6 until the syringe barrel clamp 10 is tight against the syringe barrel Do not overtighten especially when using glass syri
14. 4 Block s Retaining Bracket 3 tight against the plunger flange and tighten using the Bracket 3 Loosen the Retaining Bracket 7 on the Syringe Clamping Knob 4 Holder 8 by unscrewing the two T Knobs 9 4 Create room for the syringe s by unscrewing the Screw Caps 6 until the Bumpers 10 are at their maximum height z NOTE Mechanical stops are set using the same steps as a standard 2 syringe holder 5 Slide the syringe under the Bumper 10 placing the barrel flange within the Syringe Holder s Retaining Bracket 7 and the plunger flange within the Pusher Block s Retaining Bracket 3 NOTE If you are using syringes larger than AY ml it may be easier to unscrew one of the Thumbscrew Caps 5 and swing the Clamp Bar Assembly 11 to the side making more room to load the syringe s After the syringe s are in place swing the Clamp Bar back over the Syringe Holder 8 and reattach the Thumbscrew Cap 5 Micro Liter Multi Rack Configuration 44 Cole Farmer phone 8 0 0 3 2 3 4 3 4 0 fax 847 247 2929 Cole Parmer Touch Screen Series Syringe Pump User s Manual email infoOcoleparmer com web www coleparmer com Publication 5607 009 REV B Appendices 76 Syringe Loading Push Pull Mechanism Locking Pins 1 Thumbscrews 3 Retaining Bracket 5 Pusher Block 8 Locking pins 2 Retaining Bracket plunger flange 6 Syringe Clamp 9 Stationary Syringe holder barrel flange 4 Floating Syringe h
15. 800 323 4340 fox 847 247 2929 email infoOcoleparmer com web www coleparmer com Product Overview 10 The pump Information setup screen shows the pump s software version calibration and lubrication intervals The pump s alarm configurability includes alarms for near end of run user selectable completion of run power up keypad clicks stall detection and calibration reminder Two options are available for the Cole Parmer Touch Screen Series The analog input option which allows the analog control of the motor speed By applying a 10 VDC max to the circuit the motor speed can be varied The second option is for an internal fan These will be factory installed Pump Models The Cole Parmer Touch Screen Series is available in 5 different configurations Cole Parmer Touch Screen Infuse Only Infuse only syringe pump Accommodates 2 syringes User definable flow rates with selectable target volumes or time values to control the total infusion volume Cole Parmer Touch Screen Infuse Withdraw Infuse withdraw syringe pump Accommodates 2 syringes This unit supports infuse only withdraw only infuse withdraw withdraw infuse and continuous mode User defined flow rates with selectable target volumes One Program can be stored Cole Parmer Touch Screen Infuse Withdraw Programmable This is a Programmable Infuse Withdraw with user defined configurations programs of up to 800 steps Up to 40 programs of 20 steps each can
16. 94 cm 3 5 x 10 x 11 in 4 9 Kg 10 75 lb A C to 40 C 40 F to 104 F 10 C to 70 C 14 F to 158 F 20 to 80 RH non condensing Continuous Class 1 Il Cole Parmer 625 East Bunker Court Verson Hills IL 60061 800 323 4340 CE UL CSA CB Scheme EU RoHS Cole Parmer Touch Screen Series Syringe Pump User s Manual Publication 5607 009 REV B phone 800 323 4340 fox 847 247 2929 email infoOcoleparmer com web www coleparmer com C o E O m 3 D O C O gt e C C D D C 91 19 A Cole Parmer Product Overview Product Overview The Cole Parmer Touch Screen Series is the next generation of syringe pumps The series offers unparalleled ease of use through the high resolution color touch screen user interface The full touch screen interface enables the user to quickly create configurations and recall them for easy use The TFT color display presents all the pump operating parameters on an easy to view run screen The touch pad lock feature prevents accidental configuration changes ensuring the programs integrity is retained The entire Cole Parmer Touch Screen Series features a battery backed real time clock Programs can also be set to be started on a time delay controlled by a real time clock for unattended operation An led light on the front panel makes it easy to see if the pump is running Once the pump starts to run the display shows the p
17. Command format cwvolume IVOLUME Displays the infused volume Quick Start mode only Command format ivolume Query response lt lf gt xl lt cr gt lt f gt lt prompt gt Cole Parmer Touch Screen Series Syringe Pump User s Manual Publication 5607 009 REV B Operating the Cole Parmer Touch Screen Series SVOLUME Sets or displays syringe volume Quick Start mode only Command format svolume TVOLUME Sets or displays the target volume Quick Start mode only Command format tvolume target volume volume units Query response lt f gt Target volume not set lt cr gt lt f gt lt prompt gt or lt lf gt xl xxx cr lt f gt lt prompt gt WVOLUME Displays the withdrawn volume Quick Start mode only Command format wvolume Query response lt lf gt xl lt cr gt lt f gt lt prompt gt Time commands CITIME Clears the infused time Quick Start mode only Command format citime CTIME Clears both the infused and withdrawn times Quick Start mode only Command format ctime CTTIME Clears the target time Quick Start mode only Command format cttime phone 800 323 4340 fox 847 247 2929 email infoOcoleparmer com web www coleparmer com 62 CWTIME Clears the withdrawn time Quick Start mode only Command format cwtime ITIME Displays the infused time Quick Start mode only Command format itime Query response lt
18. Screen Series Syringe Pump User s Manual email info coleparmer com web www coleparmer com Publication 5607 009 REV B Appendices 79 Utilizing the USB Interface Mating Face USB VIRTUAL COMMPORT DRIVER INSTALLATION When you connect the Cole Parmer Touch Screen Series pump to a computer via USB for the first time Windows will seek to install a driver for communication The following section details the installation of the Virtual CommPort Driver supplied with the Cole Parmer Touch Screen Series Pump Found New Hardware Wizard 1 On connection of the pump to the computer via Mim to the Foumi Now USB the Found New Hardware Wizard will Hardware Wizard launch and ask how you wish to locate the driver Windows will search for current and updated software by Choose No not this time and click Next looking on your computer on the hardware installation CD or on the Windows Update Web site with your permission 1 Can Windows connect to Windows Update to search for software Yes this time only Yes now and every time connect a device No not this time Click Next to continue 2 Choose Install from a list or specific location Advanced and click Next This wizard helps you install software for Syringe Pump 51 If your hardware came with an installation CD or floppy disk insert it now What do you want the wizard to do O Install from a list or specific location Adva
19. be stored in memory Cole Parmer Touch Screen Push Pull Push Pull syringe pump Accommodates 2 syringes for infusion and 2 syringes for withdrawal This model supports infusion and withdrawal simultaneously at user defined flow rates and with selectable target volumes to control the total volume pumped It also supports infuse only withdraw only infuse withdraw withdraw infuse and continuous mode User defined flow rates with selectable target volumes Cole Parmer Touch Screen Push Pull Programmable This is a Programmable Push Pull pump with user defined program configurations of up to 800 steps Multiple programs can be stored in memory Modular syringe racks can be purchased to create a multichannel syringe pump e 10 channel syringe rack 4 channel syringe rack e ul syringe rack Cole Parmer Touch Screen Series Syringe Pump User s Manual Publication 5607 009 REV B pa Cole Parmer Delivering Solutions You Trust Product Overview 11 COLE PARMER TOUCH SCREEN SERIES TOUCHSCREEN BUTTON REFERENCE The following buttons are part of the Cole Parmer Touch Screen Series software SETUP NTR O Q H Settings Access the settings menu used to adjust the following parameters Date and Time Audible Alarms Pusher Block Force Display Brightness RS 232 Communications etc Fast Forward Advances the Pusher Block in the forward infuse direction press amp hold Fast Reverse Advance
20. can Link a Program any place in the with I O Events to control pump operation based on Program sequence external events Program To Link Selection 08 24 09 1 26 40 PM TO INSERT A STOP COMMAND IN A PROGRAM E a 1 From the Program Main screen choose Program m jue Step Definition to enter the Step Definition screen 2 Highlight select once the Program Step that you d want the Stop Command to follow 3 Choose the INS STEP button to access the a Tw Rr Program Steps Menu screen 4 Choose Advanced Options to enter the Set Advanced Options Link Command selection screen Advanced Options screen 5 Choose Stop to insert the Stop Command into the Program TO LINK TO A STORED PROGRAM l From the Program Main screen choose Step Definition to enter the Step Definition screen 2 Highlight select once the Program Step that you want the Link Command to follow 3 Choose the INS STEP button to access the Program Steps Menu screen 4 Choose Advanced Options to enter the Set Advanced Options screen 5 Choose Link to enter the Link Selection screen and display a list of the saved Programs available 6 Double tap the Program that you want to link to in the current Program If the desired Program is not listed on the screen use the LINE UP or PAGE DOWN buttons to scroll through the Program List Upon selection you are returned to the Step Definition screen gt id c p
21. for your test conditions Wipe any spills immediately A Satisfatory B Fair Minor Effects C Poor Moderate Effects D Severe Effects nottested phone 800 323 4340 fox 847 247 2929 email infoOcoleparmer com web www coleparmer com Cole Parmer Touch Screen Series Syringe Pump User s Manual Publication 5607 009 REV B pa Cole Parmer Delivering Solutions You Trust Appendices 84 Fuse Replacement Key Information 1 Make sure the power cord is disconnected from the main supply before servicing the fuse 2 Use only Type 3AG 1 4 x 11 4 amp 250 volt Type T time delay fuses KD Scientific Part No 5146 037 or equivalent Turn off power and remove power cord from power module Use a straight blade screw driver to pry open the access door Remove the fuse holder and then remove the fuses from this holder as shown in figure below Replace fuses and then replace the fuse holder Battery Replacement 1 Remove screw and swing cover to the side 2 Slide battery out from under clip 3 Install Lithium Coin Battery 3V 16mm CR1620 Part No 5155 288 or equivalent by sliding under clip with positive side facing out phone 8 00 3 2 3 43 40 fax 847 ui ied Cole Parmer Touch Screen Series Syringe Pump User s Manual e mail info colepa rmer com web v w cole parmer com Publication 5607 009 REV B Appendices 85 Upgrading Cole Parmer Touch Screen a Pg S s NOTE First time users
22. in the Program will be displayed in the box that is still part of the button beneath the Step Definition button 5 To review the Program Steps in detail or to update modify any of the stored Pump Control Profile Parameters choose the Step Definition button to enter the Program Steps Summary Screen The name of the Program is listed at the right of the screen and the complete list of Steps is listed in a series of buttons is on the left of the screen Step Definition 08 24 09 11 46 38 AM Program 1 PROGRRM 3 295 ml min 3 295 ml min 4 nmin INS MOVE BICOPY i34 PW EL Tia Ga mn STEP Step Definition Screen showing the list of Steps currently defined for the Program phone 800 323 4340 fox 847 247 2929 email infoOcoleparmer com web www coleparmer com 31 To review details for any individual Step in the Program select the Step you wish to review then press the Step button again to enter the Step Definition screen for that Step To edit the parameters for any Pump Control Profile follow the instructions supplied in the applicable Pump Operation Profile description contained in the Setting Program Parameters section later in this Guide To return to the Program Steps Summary screen when finished reviewing or editing the Step parameter details choose the Accept button to save your changes or choose the Cancel button to cancel any changes you made When you are finished reviewing the operating de
23. items is easy with the Cole Parmer Touch Screen Series Touch the item to select highlight the item then touch again to select it or press FI Canceling a Selection Canceling selections is easy X Syringe Selection Custom Syringe Becton Dickinson Glass all types Becton Dickinson Plasti pak Cadence Science Inc Micro Mate Glass Product Overview 12 07 21 09 11 39 05 AM za EN v Messages There are different types of messages Error messages are shown in yellow Critical Run mode Program e Set up Notices alarms confirming and verified messages are show in green e Alarms e Confirm e Verified Entering Values Entering new values is easy Use the keypad to enter the number Backspace Key Decimal point Accept the value and go back up to the previous screen Cancel and go back to the previous screen Configuration 10 30 09 10 21 47 AM Infuse Only ERROR 101 Power to the pump was lost KDS Glass SYRINGE Pyr RATES Volume TRRGET 5 mi Configuration PRESS TO CLEAR ERROR 2402 36 003 ml min Infuse Withdraw KDS Glass 10 00mi 36 003 ml min RATES W 20 ml min TARGET bee mi Custom Syringe Definition Diameter mm Volume 07 21 09 11 41 07 AM phone 800 323 4340 fox 847 247 2929 email info coleparmer com web www coleparmer com Cole Parmer Touch Screen Series Syrin
24. ml min INS MOVE BCOPY 124 9 Wi ili iM Ga EN dd DE c phone 8 0 0 3 2 3 4 3 4 0 fax 847 247 2929 Cole Parmer Touch Screen Series Syringe Pump User s Manual email infoOcoleparmer com web www coleparmer com Publication 5607 009 REV B Operating the Cole Parmer Touch Screen Series 38 PUMP OPERATION PROFILES The Cole Parmer Touch Screen Series Existing Programs and all User Defined Programs use Pump Operation Profiles as part of the Programs controlling the pump These profiles are combined with a syringe selection and any Commands or Input Output triggers to create a complete Program The following sections describe each profile along with instructions for setting up the profile The following Pump Operation Profiles are available on the Cole Parmer Touch Screen Series CONSTANT RATE RAMP RATE Time Volume Cycles STEPPED RATE PULSE FLOW Steps Time Volume Time Volume Pump Operation Profiles available on the Cole Parmer Touch Screen Series 44 Cole Farmer phone 8 0 0 3 2 3 43 40 fax 847 247 2929 Cole Parmer Touch Screen Series Syringe Pump User s Manual email info coleparmer com web www coleparmer com Publication 5607 009 REV B pa Cole Parmer Delivering Solutions You Trust Operating the Cole Parmer Touch Screen Series Constant Rate Profile The Constant Rate profile is used to run the pump at a defined flow rate and for a specific pumping mode infuse or withdraw u
25. ole Parmer Touch Screen USER S MANUAL COLEPARMERO TOUCH SCREEN SERIES a e z a S pa y i E p Ends a pa Cole Parmer wo E Mo Pes fe m HA Delivering Solutions You Trust ss E c M RR e GE E m gt E m eT Sa iut c nN In A EE AZ QR mum 2 Sawww coleparme r com ae Pu M M lt Publication 5607 009 Rev B nnm n Table of Contents 2 Table of Contents SUBJECT PAGE NO General Into moi case eectsieceaertadcsucr ane cacenonceaces snd ltda EEEE aues de A EPIS cnt 6 Safety Information A A 6 Warranty and Repair Information IT 7 Manual CSTD ro suculento trono ctra et ecnscive E 7 elicit a a a i ee 7 Repair racilles Gnd Bo TT E 7 A 7 elTe folio eee tee ener eee eae T eee ee eee 7 SSN CEN ONS tod atada 8 Produc OVeFVIBW AA 9 Tm 10 Cole Parmer Touch Screen Series Button Reference sse 1 Selecting ar lem kon a Menu eo 12 AEE o E E A ee OE E ee E E T 12 une isl NERO TTE E 12 Seriem audire RE T T LOTO 13 POW ClO COIS M l3 yo More fe Lo AP a 14 Configuring the Cole Parmer Touch Screen Series eese 15 Sao Tor TB Note SA 15 A m m 16 POW GS SE LOCI strc tie aet 17 Target Volume Time Selection cccccccccscscsssscsscscsecsesecscsececsececsecsesecsesecsese
26. orante TA Ga ig Cuon EET Z Program ENTR 2 Vins up th program EE Views down the program PT Ls phone 8 00 3 2 3 43 40 fax 847 247 2d Cole Parmer Touch Screen Series Syringe Pump User s Manual email info coleparmer com web www coleparmer com Publication 5607 009 REV B Operating the Cole Parmer Touch Screen Series J3 Configuring Custom Programs Program Z 15 CHAR MAX 00 BL OUD La Enter any 15 character alphanumeric name A 5 D G H L3 Accept the new WW E X B N M 3 Go back to the Program Selection screen x 2123 Space Select the Syringe manufacturer and Size Program Configuration 10 02 09 8 20 51 AM see page 16 To define the steps for the custom program press Step Definition The first thing to do on a custom program is to name the program Below are some predefined steps including SETUP Constant Rate a single continuous rate of flow Ramped Rate a linearly changing flow rate between C a starting and ending flow rate Steppped Rate an evenly stepped changing flow rate between a starting and ending flow rate Pulsed Rate an oscillating flow rate varying between a starting and a target rate In addition to these you can repeat go back or jump forward in a program as well as send signals to external devices or react to signals received from external devices This package of pumping profiles and commands provides users with an extremely broad array of applications that
27. program s Exporting step d Checking program Pressing the run button will start the program at the following date and time s Program is on a time delay To cancel the delay and start the pump press here Waiting for screen press Waiting for screen press or event Waiting for an event Copying a program Verify rates and target Withdrawal complete press to silence alarm Infusion complete press to silence alarm Confirm CONFIRM CONFIRM CONFIRM CONFIRM CONFIRM Verified VERIFIED VERIFIED VERIFIED VERIFIED Alarm ALARM ALARM ALARM 65 Press the lock button again to confirm you want to unlock the touch screen Press button again to delete this program Press button gain to reset calibration date Press button again to reset lubrication interval Press button again to delete step Program was copied Program was exported to the computer Verify file exists on the PC Added step d Program was successfully imported Pump is due for calibration Pump is due for lubrication Pump is due for calibration and lubrication Cole Parmer Touch Screen Series Syringe Pump User s Manual Publication 5607 009 REV B pa Cole Parmer Appendices 66 Appendices APPENDIX A SYRINGE VOLUME DIAMETER REFERENCE TABLE KD Scientific Stainless SGE Scientific Glass Cadence Science Inc Sherwood Monoject Steel Engineering Former
28. s lt 20ml 5076 BD plastic Sherwood Plastic Syringes e gt 20ml 100 Airtite Terumo Stainless Steel All 100 KDS Cole Parmer lt 20ml 20 Glass Glass KDS Glass Cadence Popper gt 20ml 30 lt 1000ul 30 Glass Plastic lt 5ml 50 Hamilton SGE gt 5ml 100 T4 phone 8 0 0 3 2 3 4 3 4 0 fax 847 247 2929 Cole Parmer Touch Screen Series Syringe Pump User s Manual email info coleparmer com web www coleparmer com Publication 5607 009 REV B Configuring the Cole Parmer Touch Screen Series 25 Setting Display Brightness 08 24 09 9 17 18 AM The backlight can be adjusted In the Set up screen select Display Brightness Press to select Display Brightness Select the Display Brightness For example if you select 80 the brightness of the display will be 80 of the maximum Accept the changes made by pressing ATI and go back to the Set up screen mM Cancel the changes made by pressing and go back to the Set up screen Set Display Brightness 07 21 09 11 31 47 AM For a Custom Value Use this selection if the is not listed Press Other Value to enter a custom Enter the percentage Accept the changes made by pressing FAT and go back to the Set up screen Cancel the changes made by pressing and go back to the Set up screen Press here for custom display brightness level Set Display Brightness 08 24 09 9 32 44 RM Backlight cl Cole Parmer phone 8 00 3 2 3 43 40 fax 847 247 2929
29. screen press E131 phone 8 00 3 2 3 43 A0 fax 847 247 2929 Cole Parmer Touch Screen Series Syringe Pump User s Manual email infoOcoleparmer com web www coleparmer com Publication 5607 009 REV B Configuring the Cole Parmer Touch Screen Series 20 Setting the Time and Date The date and time is displayed on each screen A built in battery backup will maintain the date and time even if the pump loses power or is unplugged for a period of time 08 24 09 9 17 18 AM In the Set up screen press Date Time Press NOTE The date AND time BZ must be entered NOTE Remember to activate the battery 771 ETT Y by removing the plastic tab on the H E bottom of the pump Press to change the date format Date Time Displa pray Set Date and Time 07723709 8 42 56 AM Press mm dd yy to change the date format 07 23 00 E e month day year AM e day month year year month day E El Enter the date 4 Ei 6 MA Ej NOTE Remember to use the e oje Press to change the NOTE The year must be entered as YY time format BZ i e 2009 is entered as O9 Press AM PM to change the time format e AM e PM e 24 Hour Enter the current time in hh mm ss hours minutes seconds z NOTE Remember to use the Accept the changes made by pressing Fits and go back to the Set up screen Cancel the changes made by pressing and go back to the Set up screen NY phone 8 0 0 3 2 3 43 40 fax 847 247 2929 Cole Parme
30. showing available command options phone 800 323 4340 fox 847 247 2929 email infoOcoleparmer com web www coleparmer com 45 Go To Step The Go To Command is used to instruct the Cole Parmer Touch Screen Series to jump to a particular Step in a Program This can be used to help you loop back or jump forward in a Program protocol and can be used in conjunction with I O Events to make the pump respond to a trigger from an external device When defining a Go To jump in a Program the Command targets the Step sequence position and not the function that currently occupies that position For example if you create a Go To jump to Step 4 ina Program currently a Ramp Pump Operation Profile and subsequently move a Constant Rate profile into the Step 4 position the Go To jump will then connect to the Constant Rate operation and not to the Ramp operation TO INSERT A GO TO JUMP l From the Program Main screen choose Step Definition to enter the Step Definition screen 2 Highlight select once the Program Step that you want the Go To jump to follow 3 Choose the Insert Step button to access the Program Steps Menu screen 4 Choose Advanced Options to enter the Set Advanced Options screen 5 Choose Go To to insert the Go To Step and view an updated list of all current Steps in the Program Go To Selection 07 21 09 12 33 45 PM 69 34 n min 36 ml min 36 ml min bo To BACK I ENTR Advanced Options Go To Step scree
31. slide the Springs over the Thumbscrews and tighten Thumbscrews to the Pusher Bar phone 8 0 0 3 2 3 43 40 fax 847 247 2929 Cole Parmer Touch Screen Series Syringe Pump User s Manual email info coleparmer com web www coleparmer com Publication 5607 009 REV B EEz Cole Parmer Delivering Solutions You Trust Appendices 69 Mounting a 4 X 140 Multi Rack Continued Knob Multi Syri Cl N nob 5yrin m SP MONS OVO 10 32 x 1 2 Screw 4 5101 087 f l Pc Multi Holder 2401 074 Multi Retainer 2401 070 a i Lock Washer 2 Bracket Syringe 5174 003 i Clam Knob Syringe 2401 050 lamp 2401 051 Flat Washer 2 5110 038 T Knob 2 5100 05 Dual Syri Hold but paras ete Syringe Holder Assembly 1 Remove four set screws from the Dual Syringe Holder using the provided Hex Key 2 Attach the Multi Holder onto the Dual Syringe Holder using four 10 32 x 7 screws using a phillips head screwdriver 3 Attach Clamp Bar by screwing the Multi Syringe Clamp Knob into the threaded bar attached to the Multi Holder Y Cole Parmer phone 8 00 3 2 3 43 40 fax 847 247 2929 Cole Parmer Touch Screen Series Syringe Pump User s Manual email info coleparmer com web www coleparmer com Publication 5607 009 REV B Appendices 70 Mounting a 6 10 Multi Rack Continued on page 68 Pusher Block 2400 231 T Knob 2 Lock Washer 2 2402 014 5174 003 Flat Washer 2 5110 03 Anti Syphon Bracket 2400 242 Pushe
32. the desired option in the On Event screen choose Accept to access the Program List selection screen Choose the Program name to jump to To use this command you must have defined a linkable Program Choose the Accept button to save your changes and return to the Step Definition screen NOTE Since the on event will cause a jump link to a different program be cautious not to use embedded links in your program programming Cole Parmer Touch Screen Series Syringe Pump User s Manual Publication 5607 009 REV B Operating the Cole Parmer Touch Screen Series MANAGING COLE PARMER TOUCH SCREEN SERIES PROGRAMS All Existing and User Defined Programs are stored in the Program List for ongoing use Over time you may want to manage previously created Programs to keep your Program List easy to navigate In addition the Cole Renaming A Program Follow these instructions to rename a previously saved Program l From the Program Configuration screen choose the Program Name button to enter the Program Mode screen Parmer Touch Screen Series allows you to export 2 From the list of available Programs select Program information to an externally connected pump or press once the Program you want to rename then to a computer that will be used to control operation This choose the File Options button to enter the File section of the Guide describes the file management Options screen facilities available on the Cole Parme
33. 00mi Infuse Only 36 003 ml min Press 2 Depending on the Mode the appropriate set rate screen will be displayed To change the units press the units Enter the flow rate 26 003 ml min ml min BACK M ENTR Press to select the Press to select the maximum volume for the minimum volume for the syringe size selected syringe size selected 3 In the Units Selection Display select the volume Units Selection 06 25 09 8 21 56 AM and the time base Current selection ml min BACK MM ENTR cl phone 8 0 0 3 2 3 43 40 fax 847 247 2929 Cole Parmer Touch Screen Series Syringe Pump User s Manual e mail infoOcoleparmer com web www coleparmer com Publication 5607 009 REV B Configuring the Cole Parmer Touch Screen Series 18 Target Volume Time Selection Configuration 10 30 09 02 09 04 AM 1 In the Configuration Display enter the target volume or time In this example we want a volume of 5 ml KDS Glass 10 00mi Infuse Only g NOTE Target time is only allowed in 36 003 ml min infusion only or withdrawal only modes Volume 2 Depending on the Mode either Target Volume 5 mi I W or W I will appear or Target Volume or Target Time Selection I only or W only Press Here E NOTE For time enter h m s or press again to select secs Time is accurate to 0 01 secs Remember to enter the Press to change the units 3 To change the units press the units aa TEO Press to select tar
34. 23 phone 800 323 4340 fox 847 247 2929 email infoOcoleparmer com web www coleparmer com Units pl min pl min pl min pl min pl min pl min pl min pl min nl min nl min nl min nl min nl min nl min nl min nl min nl min nl min nl min nl min Maximum Rate 1 589 3 180 6 358 17 630 35 249 79 640 158 984 318 126 795 510 1 588 3 181 3 308 11 044 21 539 31 190 54 383 69 852 105 985 190 992 215 803 Cole Parmer Touch Screen Series Syringe Pump User s Manual Publication 5607 009 REV B Appendices Units pl min pl min pl min pl min pl min pl min pl min pl min pl min ml min ml min ml min ml min ml min ml min ml min ml min ml min ml min ml min 67 Appendices 68 APPENDIX C RACK ACCESSORIES OPTIONS Mounting a 4 X 140 Multi Rack Continued on page 66 Flat Washer 2 5110 038 P T Knob 2 usher Block 2402 014 Lock Washer 2 5174 003 Pusher Bar 2400 278 Spring 3 5009 164 Washer 3 5143 003 Flat Head Screw a Anti Syphon Bar 5137 0 2400 279 Thumbscrew 3 5173 006 Pusher Block Assembly 1 Remove Dual Syringe Anti Syphon Bracket by unscrewing and removing the two T Knobs and two Spring Washers 2 Attach the Pusher Bar to the Pusher Block using two flat head screws 3 Attach the Anti Syphon bar to the Pusher Bar with three Thumbscrews and three Springs Slide Thumbscrews thru the Pusher Bar s holes
35. 3 0 50 29 0 Nipro Size Diameter 1 ml short 6 6 mm 1 ml long 4 7 2 5 ml 9 0 5 13 0 10 15 8 20 20 1 30 23 2 50 29 1 Suggested Force Level Settings for Common Syringes Syringe Type Material Capacity Force Setting Common Manufacturer s Plastic Syringes Scull ae o pue SENOR gt 20ml 100 Airtite Terumo Stainless Steel All 100 KDS Cole Parmer Glass Glass dll mala KDS Glass Cadence Popper gt 20ml 30 lt 1000ul 30 Glass Plastic lt 5ml 50 Hamilton SGE gt 5ml 100 phone 8 00 3 2 3 43 40 fax 847 247 2929 Cole Parmer Touch Screen Series Syringe Pump User s Manual email info coleparmer com web www coleparmer com Publication 5607 009 REV B pa Cole Parmer Delivering Solutions You Trust _ APPENDIX B MIN MAX FLOW RATES Nominal Minimum Maximum Flow Rates for Various Syringes Actual Limits will vary depending on syringe manufacturer Syringe Size 0 5 ul 1 pl 2 pl 5 pl 10 pl 25 ul 50 ul 100 ul 250 pl 500 pl 1000 pl 1 ml 3 ml 5 ml 10 ml 20 ml 30 ml 50 ml 100 ml 140 ml Syringe ID 0 103 mm 0 146 mm 0 206 mm 0 343 mm 0 485 mm 0 729 mm 1 03 mm 1 457 mm 2 304 mm 3 256 mm 4 608 mm 4 699 mm 8 585 mm 11 989 mm 14 427 mm 19 050 mm 21 590 mm 26 594 mm 35 700 mm 3 948 mm Minimum Rate 6 18 12 301 33 96 67 72 153 42 306 24 612 72 1 533 3 06 6 129 6 373 21 272 41 485 60 073 104 74 134 533 204 122 367 839 415 6
36. 47 247 2929 Cole Parmer Touch Screen Series Syringe Pump User s Manual email infoOcoleparmer com web www coleparmer com Publication 5607 009 REV B Table of Contents 5 SUBJECT PAGE NO Appendice S es 66 Appendix A Syringe Volume Diameter Reference Table sss 66 Appendix B Min Max Flow alles caeteris e t orte merit iom Dada di UN 67 Appendix C Rack Accessories COIIIORS vsesestesteusqbrepE teorica 68 Mounting a 4xT4O OIE aten 68 Mounting do TO MUERO consorcios 70 Syringe Leading 2x140 5 6 10 IWR GS eran adiic 72 Mounting a Micro liter AA A 73 Syringe Loading Micro Liter Multi Rack esses 75 Syringe Loading Push Pull Mechanism espurio 76 Appendix D External Connections sss 77 User lO Connector opeclicallons seiscientos ionaisicicss 77 Analog npor OPON vetados nene iento oido odres 78 Mir A e E o OERA E AEE EEE 79 S PPAT EE e soda occ 81 dini 92 Append E Mailed db E at 83 e 83 Fuse Replacement esencial 84 Battery RED ICC SIHENI stat lcdo ota corola 84 Upgrading Cole Parmer Touch Screen Series Software suus 85 Tro ble holing AA tea seeec sees vases wicec N E E yacesvnces uncci eens 86 Appendix F Auto Fill Valves sse 87 A oa o ee ee oe eee ee eee nen eee eee eee ee 87 Appendix G Ordering LOL Osona tras 88 44 Cole Farmer phone 800 323 4340 tax 84
37. 5 lbs of linear force is available This force is user adjustable to ensure the right force is applied for the various syringe sizes The superior design of the full metal chassis provides noise isolation and anti vibration features for increased reliability The spill dam is designed to prevent fluids from ingressing into the sealed display All syringe racks are hardened rolled steel and will not deform with pressure Cole Parmer Touch Screen Series Syringe Pump User s Manual Publication 5607 009 REV B pa Cole Parmer Delivering Solutions You Trust_ Easy external connections to a computer or other control devices are made through USB interface or RS232 9 pin Dsub Simple ASCII commands make communication with the pump easy For direct control of the pump the user can use the O interface 15pin Dsub Two trigger outputs and a trigger input in for external events such as a process parameter is met The footswitch input will allow the control of the pump through an external device The unit also has an output for run indication allowing connection to a remote light All the models accommodate dual syringes except for the push pull pumps which have two syringes on each side for simultaneous infusion and withdrawal Complete flexibility is offered with the user able to use ANY manufacturer s syringes with sizes ranging from 0 5 ul to 140 ml Modular configuration is now done through the field installable syringe mechanisms T
38. 7 247 2929 Cole Parmer Touch Screen Series Syringe Pump User s Manual email infoOcoleparmer com web www coleparmer com Publication 5607 009 REV B General Information General Information SAFETY INFORMATION Please read the following safety precautions to ensure proper use of your syringe pump If the equipment is used in a manner not specified the protection provided by the equipment may be impaired To Prevent Hazard or Injury USE PROPER LINE CORD Use only the specified line cord for this product and make sure line cord is certified for country of use The operating voltage range for the Cole Parmer Touch Screen Series is 100 240 vac 50 60 Hz GROUND THE PRODUCT This product is grounded through the grounding conductor of the power cord To avoid electric shock the grounding conductor must be connected to earth ground Before making any connections to the input or output terminals of the product ensure that the product is properly grounded MAKE PROPER CONNECTIONS Make sure all connections are made properly and securely Any signal wire connections to the unit must be no longer than 3 meters OBSERVE ALL TERMINAL RATINGS Review the operating manual to learn the ratings on all connections USE PROPER FUSE Use only specified fuses with product AVOID EXPOSED CIRCUITRY Do not touch any electronic circuitry inside of the product AVOID PINCH HAZARD A pinch hazard may exist between the pusher block and end bl
39. 7 2929 Cole Parmer Touch Screen Series Syringe Pump User s Manual email info coleparmer com web www coleparmer com Publication 5607 009 REV B pa Cole Parmer Delivering Solutions You Trust Operating the Cole Parmer Touch Screen Series I O OUT Trigger The I O OUT Trigger command is used to send a signal to an external device when the Step in the Program is reached Trigger 07 21 09 12 45 33 PM Trigger 1 Trigger e Synchronize Valve Valve On Valve Off Valve Auto BACK I ENTR I O OUT Trigger Advanced Options menu The following options are available when setting an I O OUT Trigger command e Trigger 1 Specifies output via the Trigger 1 Pin 4 port When selected you must also specify whether the signal to be sent is High Signal or Low Signal High Signal Sets the output signal to logic high Low Signal Sets the output signal to logic low e Trigger 2 Specifies output via the Trigger 2 Pin 5 port When selected you must also specify whether the signal to be sent is High Signal or Low Signal High Signal Sets the output signal to logic high Low Signal Sets the output signal to logic low e Synchronize Select this to send a signal via Pin 6 to a connected pump to trigger activity When selected you must define whether the desired action is to start an Infuse activity or a Refill Withdraw activity Start Infuse Defines the rising edge signal to trigger an infusion action
40. Cole Parmer Touch Screen Series Syringe Pump User s Manual email info coleparmer com web www coleparmer com Publication 5607 009 REV B Configuring the Cole Parmer Touch Screen Series 26 Setting the Pump Address 08 24 09 9 17 18 AM Up to 100 pumps can be linked together Each pump can be given a unique address In the Set up Screen press Pump Address Valid entries are 00 to 99 Enter the pump address Accept the changes made by pressing Ja 71 Em and go back to the Set up screen H E Cancel the changes made by pressing a and go back to the Set up screen Set Pump Address 08724709 9 34 02 AM Pump Address b Setting the RS 232 Baud Rate 07 21 09 11 20 35 AM The Cole Parmer Touch Screen Series has an RS 232 port for serial communications To adjust the baud rate from 9600 to115 200 in the Set up screen press Baud Rate Select the Baud Rate Accept the changes made by pressing Fim and go back to the Set up screen Cancel the changes made by pressing and go back to the Set up screen 07 21 09 11 34 16 AM Press here to select Baud Rate cl phone 8 00 3 2 3 43 A0 fax 847 247 2929 Cole Parmer Touch Screen Series Syringe Pump User s Manual email infoOcoleparmer com web www coleparmer com Publication 5607 009 REV B paz Cole Parmer Delivering Solutions You Trus Configuring the Cole Parmer Touch Screen Series Resume Run on Power Loss If Resume Run on Power Loss is selected the pump will power u
41. NAL PUMP CONTROL 4 Setup the Port Settings as shown below and click OK This section of the Cole Parmer Touch Screen Series manual Ax ort Settings describes the control of the pump using an external computer device If communicating via the USB Port see Appendix D for one time installation instructions of USB Bis per second 175200 E Driver Data bits fe H Parity None y Setting Up HyperTerminal Stopbis 2 El HyperTerminal is a Windows application designed to Flow contol REE support the external control of devices such as the Cole Parmer Touch Screen Series pump through an RS 232 _RestoreDefauts_ or USB connection The following instructions describe the configuration of the HyperTerminal application 1 Select Start All Programs Accessories Communications HyperTerminal 5 Verify the Settings are as shown below 2 Enter a name for a New Connection PHD _Ultra_Comm Properties Axi i e CP Touchscreen then click OK ConnectTo Settings Function arrow and ctrl keys act as Terminal keys C Windows keys Connection Description Backspace key sends ay Han A CtleH C Del C Cti H Space Ctrl H Emulation Enter a name and choose an icon for the connection Auto detect Femina Sel Name Syringe Pump Telnet terminal ID an SI Backscroll buffer lines 500 Play sound when connecting or disconnecting Input Translation C o f O m 3 D
42. Program If you choose Advanced Options you will taken to the Select Advanced Options screen phone 800 323 4340 fox 847 247 2929 email info coleparmer com web www coleparmer com Q e 10 When you have completed all parameter entries on the Step Definition screen or completed the required entries for Advanced Options choose the e 36 Complete the parameter entry applicable to the selected Pump Operation Profile follow the detailed instructions supplied in the Pump Operation Profiles Existing and User Defined Programs section later in this Guide If you selected Advanced Options follow the instructions supplied in the Incorporating Advanced Options Into a Program section later in this manual NOTE f you do not complete the required parameter entry for a Step subsequent Step additions may be ignored You should enter all required parameters for a Step when creating it to ensure that the application software can assemble your Program without errors BACK button to save your changes and return to the Program Steps Summary screen Repeat items 7 10 in this procedure to include additional Steps in the Program NOTE When adding a Step to a Program the Step is added after the currently selected Step i e the Step that is highlighted in blue 12 When you are done adding all required Steps to the Program choose the BACK button to return to H the Program Main screen Cole Parmer Tou
43. R IN PWR OUT 430V Protected by resettable fuse GND GND RS 485 A TIED TO PIN 4 100 Q Ye w to RS 485 B TIED TO PIN 3 AN Deniador TIED TO PIN 6 RS 485 A TIED TO PIN 5 RS 485 B RS 485 In Out IEEE 1394 Sockets USB or USB or Rs 030 jn PUMP RS 485 RS 485 PUMP RS 485 RS 485 PUMP IN RS 232 D Sub9 ADDR OUT eee 394 IN ADDR cs eee penn D Sub 9 Cable Cable F F Cable Daisy Chaining via RS 485 NOTE When daisy chaining with RS 485 at a minimum every 4th pump in the daisy chain must be sel oowered i e another stand alone unit This can be affected by force selection NOTE When applying power to pumps in a daisy chain apply power to the last group in the chain first and work backwards X NOTE When removing power be aware that power removed from a stand alone unit will cause power to be removed from all RS 485 powered units deriving power from that stand alone unit ds NOTE Power may be removed from any group of pumps except the first group without affecting communications downstream ds NOTE Each pump in the daisy chain must have a unique address The first pump must be set to address 00 X Y phone 8 0 0 3 2 3 43 40 fax 847 247 2929 Cole Parmer Touch Screen Series Syringe Pump User s Manual email infoOcoleparmer com web www coleparmer com Publication 5607 009 REV B Appendices 83 APPENDIX E MAINTENANCE Maintenance To clean the exterior surfaces use a lin
44. Set up 08 24 09 9 17 18 AM The maximum linear force of the syringe pump is 75 lbs Date Time ci iol or 35 kgs This force is sufficient to damage delicate low volume syringes as well as many standard syringes if Audible Alarms pumping viscous fluids The of maximum force applied by the pusher block can be changed Es een Displ P In the set up screen press Force Brightness Lud EE Touchpad Resume Run NOTE A minimum value of approximately a iii p 30 is required to overcome friction forces in the mechanism You may have to set the Press Here lorce level to a higher value depending on the backpressure friction in your system Set Force Level 07 21 09 11 27 59 AM Set the force level Press Other Value to enter a custom force Accept the changes made by pressing and go back to the Set Force screen Cancel the changes made by pressing 771 ETT and go back to the Set Force screen ba For a Custom Force Press here to enter Enter the precentage for custom force custom force Accept the changes made by pressing and go back to the Set Force screen Cancel the changes made by pressing and go back to the Set Force screen Set Force Level 08 24 09 9 31 24 AM Force C o H O m 3 D O C O gt e C C D D C 91 19 Suggested Force Level Settings for Common Syringes Syringe Type Material Capacity Force Setting Common Manufacturer
45. Sets or displays the infusion rate Quick Start mode only Command format irate rate rate units max min Query response lt lf gt xl xxx cr lt f gt lt prompt gt WRAMP Sets or displays the target withdraw rate while ramping Quick Start mode only Command format wramp start rate end rate rate units ramp time in seconds Query response lt f gt Ramp not set up lt cr gt lt f gt lt prompt gt or lt f gt Starting rate xl xxx lt cr gt lt f gt Ending rate xl xxx cr lt f gt Ramp time seconds lt cr gt lt f gt lt prompt gt phone 800 323 4340 fox 847 247 2929 email infoOcoleparmer com web www coleparmer com 61 WRATE Sets or displays the withdraw rate Quick Start mode only Command format wrate rate rate units max min Query response lt lf gt xl xxx cr lt f gt lt prompt gt e NOTE For commands requiring rate units use the following format m u n p h m s Ex m m milliliter minute Ex n s nanoliter second Volume commands CIVOLUME Clears the infused volume Quick Start mode only Command format civolume CTVOLUME Clears the target volume Quick Start mode only Command format ctvolume CVOLUME Clears both the infused and withdrawn volumes Quick Start mode only Command format cvolume CWVOLUME Clears the withdrawn volume Quick Start mode only
46. The Number of Steps that will be created in the profile During a Stepped Rate profile the Cole Parmer Touch Screen Series calculates a series of equal rate increases that will vary the flow from the starting value to the ending value You enter the Number of Steps you want to use The Target Time defines the total length of pumping time with the Target Time value divided equally into each stepped rate A Stepped Rate profile can be applied to an increasing or decreasing rate application When creating or editing a Stepped Rate profile you can set the rate in ml ul nl or pl units of volume using sec or h m s hours minutes seconds as the units of time The system automatically calculates a minimum and maximum flow rate based on the syringe selected or custom defined The min max values are made available as button selection options on the Set screen Y Cole Parmer hone 8 0 0 o 3 2 3 43 40 fax 847 247 2929 Cole Parmer Touch Screen Series Syringe Pump User s Manual Delivering Solutions You Trust P email info coleparmer com web www coleparmer com Publication 5607 009 REV B Operating the Cole Parmer Touch Screen Series 42 TO SET UP EDIT A STEPPED RATE PROFILE 1 From the Stepped Definition screen for a Stepped 9 Select the Total Time button it should be selected Rate profile choose the Direction button to toggle by default as indicated by the active data entry the Flow Mode between Infuse and Withdraw box to the right
47. Units of Volume associated with Volume 1 or Volume 2 are not correct for your application choose the Units button associated with either parameter to enter the Units selection screen Select the unit of measure button ml ul nl pl applicable to your application then choose the Accept button to return to the Set Pulse Volumes screen When both Volume parameters are set to the correct values choose the Accept button to return to the Pulse Definition screen 17 Select the of Pulses button to enter the Set 18 Pulses screen On the Set Pulses screen enter the desired value using the keypad then choose the Accept button Cole Parmer Touch Screen Series Syringe Pump User s Manual Publication 5607 009 REV B pa Cole Parmer Delivering Solutions You Trust Operating the Cole Parmer Touch Screen Series Incorporating Advanced Options Commands and I O Into A Program Cole Parmer Touch Screen Series Programs can incorporate a variety of commands that expand the versatility of the system by permitting convenient looping chaining of events sending signals to external devices or accepting inbound signals from external devices These Advanced Options controls are described in this section of the Guide To access the Advanced Options choose Advanced Options from the Select Profile screen Advanced Options Selection 07 21 09 12 32 27 PM BACK Program Step Profile Selection Advanced Options screen
48. a Cole Parmer Delivering Solutions You Trust_ Operating the Cole Parmer Touch Screen Series STEP BY STEP OPERATION EXAMPLE USING A CUSTOM PROGRAM The following steps describe operation using a Custom Program In the following description we are assuming the use of a Program that is already saved on the Cole Parmer Touch Screen Series Note that if you make any changes to the Program s operating parameters and choose Accept on the page where the changes are made the changes automatically become part of the stored Program for future use 1 From the Program Configuration screen the Program you wish to use should be displayed in the Program Select button If the Program is not displayed select the correct Program using the procedure outlined in Running The Pump 2 Choose the Syringe Select button to enter the Syringe Selection screen 3 Follow the instructions in the Syringe Selection section of this Guide to complete the selection of a syringe from the builtin syringe definition list or to create a new syringe definition When finished choose the Accept button to save your changes or choose the Cancel button to cancel your changes and return to the Program Configuration screen 4 Review the Pump Control Profile Steps described in the Step Definition button Note that the software will display the first three Steps in the Program in the main button area If the Program uses more than three Steps the last Step
49. arameter commands rate dia vol etc it is necessary to execute from the Quick Start configuration screen Using the Cole Parmer Touch Screen Series Series Pump Chain Commands Commands may be abbreviated to the first four letters i e address would be abbreviated addr A space must follow the command if arguments are included IF the pump address is nonzero the one or two digit pump address precedes the command without any separator For example to set the infuse rate for pump 12 the command would look like 12irat 3 2 u m If the pump address is one digit it doesn t have to be preceded by a O NOTE If the USB port is used on a pump with a nonzero address the pump address e does not need to be used phone 800 323 4340 fox 847 247 2929 email infoOcoleparmer com web www coleparmer com 57 Every line of the response from a pump with a nonzero address is prefixed by the two digit pump address prefixed with a O if necessary followed by a colon No colon is used to separate the pump address from the prompt however In the command list below the following convention is used Required parameter Optional parameter Separator between parameter choices Numeric value without preceding zeros HHH Numeric value with preceding zeros A range of values lt cr gt Carriage return lt lf gt Line feed lt sp gt Space prefix Pump address prefix in the format if the pump address is not zero lt pro
50. armer com web www coleparmer com 33 Deleting A Program Follow these instructions to delete a previously saved Program l From the Program Configuration screen choose the Program Name button to enter the Mode Selection screen From the list of available Programs select press once the Program you want to delete then choose the File Options button to enter the File Options screen Choose Delete Program The application will display a warning message in the Message Area asking you to confirm your deletion request Choose Delete Program again to confirm the deletion and return to the Mode Selection screen Cole Parmer Touch Screen Series Syringe Pump User s Manual Publication 5607 009 REV B pa Cole Parmer Delivering Solutions You Trus _ Operating the Cole Parmer Touch Screen Series COLE PARMER TOUCH SCREEN SERIES PROGRAM EXPORT AND IMPORT The Cole Parmer Touch Screen pump permits the daisy chaining of multiple pumps as well as integration with control by an external computer through HyperTerminal To facilitiate operation in these modes the Cole Parmer Touch Screen Series application software includes a variety of commands designed to simplify the export import of Programs between the pump and external devices This section outlines the use of these commands NOTE Do not attempt to Export Import BZ Programs while the pump is running NOTE Do not change screens while e Importing Ex
51. can be easily configured with complex external programming Programs can be edited and saved under a new name allowing them to be simply edited to fit another application Steps can be copied moved inserted or deleted Y phone 8 0 0 3 2 3 43 40 fax 847 247 2929 Cole Parmer Touch Screen Series Syringe Pump User s Manual email infoOcoleparmer com web www coleparmer com Publication 5607 009 REV B C 9 n O D D O O C C JR D D C 91 19 paz Cole Parmer Delivering Solutions You Trus Operating the Cole Parmer Touch Screen Series Setting A Time Delay You can set the Cole Parmer Touch Screen Series to run at a specific date and time in the future This delayed run function allows you to set up all the parameters for operation then have the pump start unattended at the required time SETTING A TIME DELAY FOR PROGRAM OPERATION l From the Program Configuration screen choose the Set Delay Parameters button to enter the Set Delay Date and Time screen 2 To enter the date select the Date button and type the desired date using the onscreen number pad Select the Date Format button to toggle between Month Day Year m d y Day Month Year d m y and Year Month Day y m d formats Enter your values in two digit format for each value For example April 3 2009 would be entered as 04 03 09 in m d y format 3 To enter the time select the Time button and type the desi
52. ch Screen Series Syringe Pump User s Manual Publication 5607 009 REV B Operating the Cole Parmer Touch Screen Series 937 Modifying an Existing User Defined Program Once you have created a Program or have reviewed an Existing Program you may have a need to modify the structure of the Program i e the types of Steps and Commands included not just changes in the operating i parameters for a specific Step The following procedures will help you to efficiently modify a stored Program DELETING A STEP FROM A PROGRAM From the Program Configuration screen choose the Step Definition button to enter the Program Steps Summary screen 2 Highlight select with a single touch the Step that you want to delete CHANGING THE ORDER OF STEPS IN A PROGRAM 3 Choose the Delete Step button The application will display a warning message in the Message Area asking you to confirm your deletion request l From the Program Configuration screen choose the Step Definition button to enter the Program Steps Summary screen Program Configuration 10 29 09 09 44 07 AM Step Definition 08 24 09 9 49 53 AM Step 1 Delay Program METHOD Step 2 Ramp CONFIRM Press button again to Suri 3 295 ml min 3 335 nimi Ca yringe elete step Cadence 30 mi 22 7 mm pai O Rate Step Definition PRESS TO CLEAR MESSAGE Step 1 Constant Rate Ma DELAY INS Budd 1 24 Step tem 2E e m a EZ Step 3 Constant Rate HOVE ETT DEL cong a Ed B
53. cr gt lt f gt lt prompt gt The number of steps displayed is a four digit number right justified and padded with spaces FORCE Sets or displays the infusion force level in percent Valid range is to 100 Command format force 1 100 Query response lt lf gt lt cr gt lt f gt lt prompt gt METRICS Displays the pump metrics The operation of this command is covered in the Cole Parmer Touch Screen Series Configuration document Command format metrics phone 800 323 4340 fox 847 247 2929 email infoOcoleparmer com web www coleparmer com 59 POLL Sets or displays the polling mode state In polling mode prompts are inhibited if they aren t generated by a typed command Valid states are on or off Command format poll on off Query response lt f gt Polling mode is OFF lt cr gt lt f gt lt prompt gt or lt f gt Polling mode is ON lt cr gt lt lf gt lt prompt gt TILT Calibrates the tilt sensor Command format tilt TIME Sets or displays the date and time Command format time mm dd yy hh mm ss Query response JE 4 E E 4HE HEHEHE EM cro lt f gt lt prompt gt The date order format is dependent on the settings made when setting the date from the touch screen The time order format is 24 hours VALVE Displays or sets the valve state When the valve is set to auto the motor direction determines the valve state Valve defaults to Au
54. csesecsesecsesecaeseeseseeseseeaes 18 Previewing Meson UI tdi 19 Ad Cole Farmer phone 800 323 4340 tax 847 247 2929 Cole Parmer Touch Screen Series Syringe Pump User s Manual email infoOcoleparmer com web www coleparmer com Publication 5607 009 REV B Table of Contents 3 SUBJECT PAGE NO Configuring the Pump s General Parameters cccccccssssscsesesessssescsesesececscseseseeecseseseseecseseseeeeees 19 Seting the Timeand Dale RENE 20 Setting the Avdible Alarm Sorento E T A a 21 For Near Endo PUn eee I aeae 22 Locking the Touchscreen sse nennen tnnt tennis 23 Seling the Force LIS NNI E 24 Selina me DISPO aoi fo IIT NNI TEE OU 25 Seting the Pomp VCC ET TOO 26 Seting ihe RS 232 Baud Rale stan iio 26 Resume Run on Power Loss N E 27 Seling and Viewing Pump Informati Me caannpa sa 27 Operating the Cole Parmer Touch Screen Series e sssessosessoessoessocessoessoeesooeso 28 Running the Pump oooocococcococococonononncononononooncnnonononnononoonononcn entente tenente tnter tete retener tne 29 GUS PEOR VOTO oia 30 Step by Siep Operaling EXP PET TU 3 Configura Custom Programs sirenita errar Vom bud 32 Setting a Time Delay for Program O Peral Olot ticas 34 Creating a Custom New Program cccsssssssessesscesseseeseesseseceseeseeseesecsecseeseeeseeseesecsecseeeeseseeseeseeaes 35 Modifying an Existing User Defined Progra sao erc dete uei 37 Changing the Order of Steps in a Pro sesiesiiyopsseiisessi nasai
55. d This command requires that you have a program set with the specific actions steps you want to perform if the event occurs so that you can choose the Program name being linked by this command Input High to Low Will link to the desired program upon a logic low input signal falling edge Input Low to High Will link to the desired program upon a logic high input signal rising edge User Press Will link to the desired program upon a manual input Motor Stall Will link to the desired program upon a Motor Stall event Withdraw Will link to the desired program upon a Withdraw activity e Infuse Will link to the desired program upon an Infuse activity phone 800 323 4340 fox 847 247 2929 email infoOcoleparmer com web www coleparmer com l e 51 TO INSERT AN I O IN EVENT LINK COMMAND From the Program Main screen choose Step Definition to enter the Step Definition screen Highlight select once the Program Step that you want the I O IN Event Link command to follow Choose the INS STEP button to access the Program Steps Menu screen E Choose Advanced Options to enter the Select Advanced Options screen Choose the O IN Event Link button to enter the On Event Step Definition Screen Select the desired Event type that you want to have the event associated with from the options available Input Low Input High User Press Motor Stall Withdraw Infuse After selecting
56. e between Infuse and Withdraw operation Step 4 Pulse 07 21 09 12 28 51 PM Infuse Rate 1 0 mimin Rate 2 0 ml min O Yolume BACK MM ENTR 0 Pulses Step Definition screen for a Pulse Profile with Volume mode selected 2 Choose the Rates button to enter the Set Pulse Rates screen 3 Select the Rate 1 button it should be selected by default as indicated by the active data entry box to the right of the button Enter the flow rate value desired using the keypad or select the Minimum Rate or Maximum Rate button 4 If the Units of Rate are not correct for your application choose the Units button 5 On the Units Selection screen select the unit of measure ml ul nl or pl and the unit of time sec min hr as appropriate then choose Accept to confirm your selections 6 Repeat Steps 3 to 5 for the second flow rate by selecting the Rate 2 button and continuing data entry 7 When all parameters are correctly set on the Set Pulse Rates screen choose Accept to confirm your settings and return to Pulse Definition screen 8 Select the Volume or Time button with indicator to determine how the pump cycle length will be managed Volume calculates each cycle stage by pumping for the length of time needed to pump the specitied volume Time manages each cycle stage by pumping for the amount of time specified 9 Depending on whether you have selected the Volume or Time button in the preceding step ch
57. eb www coleparmer com Cole Parmer Touch Screen Series Syringe Pump User s Manual Publication 5607 009 REV B Tot Cole Parmer a Y D E e C O Configuring the Cole Parmer Touch Screen Series 16 Syringe Selection Configuration 10 30 09 02 05 11 AM 1 In the Configuration Display select the emu syringe button KDS Glass 10 00mi ga 2 Select the manufacturer type Then the available Syringe Selection syringe sizes will be displayed In this example we have selected a KDS 10ml Glass Syringe syringe Press Ka Syringe Size Selection 07 21 09 11 39 46 AM Press LINE rmm 3 For a Custom Syringe use this selection if 07 21 09 11 39 05 AM syringe manvfacturer is not listed Bm custom syringe EAT Custom Syringe Definition Display Custom Syringe Definition 07 21 09 11 41 07 AM Press to enter the inside diameter of the syringe A Press to enter the total change the syringe volume units ul ml phone 800 323 4340 tax ibid email info coleparmer com web www c Cole Parmer Touch Screen Series Syringe Pump User s Manual Publication 5607 009 REV B Configuring the Cole Parmer Touch Screen Series 17 Flow Rate Selection Configuration 10 30 09 02 02 42 AM 1 In the Configuration Display enter the flow rate s In this example we want to enter 36 003 ml min KDS Glass 10
58. er Touch Screen Series Syringe Pump User s Manual email infoOcoleparmer com web www coleparmer com Publication 5607 009 REV B Operating the Cole Parmer Touch Screen Series 323 Creating a Custom New Program If none of the Programs stored on the Cole Parmer Touch Screen Series match your requirements you can create a new Program and store the Program for use The following flow diagram outlines the basic steps you will follow to create a new Program Choose Syringe Select Syringe Select Screen Method Main Y Choose Step Definition y Program Steps Summary Screen Method Selection Add Step New Method Step Definition Screen Name Method Complete Parameter Entry Choose Accept Add More Steps Steps Summary Screen New User Defined Program creation workflow TO CREATE A NEW USER DEFINED PROGRAM Program _ 15 CHAR MAX F he P Confi i USA O ULE LR E Lu the Program Selection screen A S D G H L3 2 RE Bl dc then choose Accept or press F4 B N M 3 On the Program Name screen type the name of your Program using the onscreen keyboard Choose the Symbols Numbers button ETZE to New Program Name Entry screen showing letter keys display the list of available numbers and symbols i To view numbers symbols choose the use button that can be included in the P
59. er Cole Parmer Instrument Company 625 East Bunker Court Vernon Hills Illinois 60061 1844 Phone 847 549 7600 Toll Free 800 323 4340 Fax 847 247 2929 Telex 28 9405 We herewith declare that the following product Product Name Cole Parmer Touch Screen Series Syringe Pump Model No Cole Parmer Touch Screen 74905 xx To which this declaration relates is in conformity with the applicable EC Directives harmonized standards and other normative requirements Application of Council Directive s 2006 95 EC 2004 108 EC Standard s to which conformity is declared Safety EN 61010 1 2001 2nd Edition Emmissions Immunity EN 61326 2006 05 01 EN 61000 4 2 1995 A1 1998 A2 2001 EN 61000 4 3 2002 EN 61000 4 4 2004 EN 61000 4 5 1995 A1 2001 EN 61000 4 6 2007 EN 61000 4 8 1993 A1 2001 EN 61000 4 11 2004 EN 61000 3 2 2000 EN 61000 3 3 1995 A1 2001 CISPR11 2003 A1 2004 Group 1 Class A EMC and Safety compliance were evaluated by Intertek ETL Semko Reference test report file numbers 3189291Box 001 003 005 B I the undersigned hereby declare that the equipment specified above conforms to the above Directive s and Standard s Place United States of America Date October 19 2009 C Signature Beth Bauman WEZ Cole Parmer TNT Delivering Solutions You Trust_ VP Engineering Operations Position Cole Parmer Touch Screen Series Syringe Pump User s Manual Publication 5607
60. erminal choose Transfer Capture Text Stop Your Program is now saved on the external computer phone 800 323 4340 fox 847 247 2929 email infoOcoleparmer com web www coleparmer com 235 IMPORTING A PROGRAM FROM AN EXTERNAL COMPUTER Follow these instructions to import a Program from an external computer Connect the pump to the external computer via a RS 232 or USB cable and set the Address value to OO using the Set Pump Address command in the Settings menu On the computer open the HyperTerminal application and verify that the computer can communicate with the pump In HyperTerminal click on the Properties icons and choose the Settings tab on the pop up box that is displayed Click on the ASCII Setup button In the Line Delay field enter 500 This will set a 500 millisecond delay after each line is transferred during the import process Click OK twice to return to the HyperTerminal Main Menu screen In HyperTerminal choose Transfer Send Text File Select the Program that you want to import to the pump and click Open Before disconnecting verify that the Program was transferred by choosing Program Select from the Program Main screen at the destination pump then browse the Program menu to confirm that the new Program is now saved at the pump Cole Parmer Touch Screen Series Syringe Pump User s Manual Publication 5607 009 REV B Operating the Cole Parmer Touch Screen Series 56 EXTER
61. f Rate are not correct for your application choose the Units button On the Units Selection screen select the unit of measure ml ul nl or pl and the unit of time sec min hr as appropriate then choose ENTR to confirm your selections When all parameters are correctly set on the Set settings and return to Constant Rate Definition screen a Rate screen choose ENTR to confirm your Choose the Volume button to enter the Set Volume or Time screen On the Set Volume or Time screen select the Volume or Time button as desired Enter the desired value using the keypad or select the Maximum Volume button 10 If the Units of Volume Time are not correct for your 11 12 When all parameters are correctly set on the Set 13 Choose ENTR again to return to the application choose the Units button to the right of the parameter entry box For the Units of Volume this choice takes you to the Units Selection screen For the Units of Time option this choice will toggle the button between sec seconds and h m s hours minutes seconds To use the h m s option enter your time value in hours minutes and seconds separating each value with a colon If you are changing the Units of Volume on the Units Selection screen select the unit of measure ml ul nl or pl as appropriate then choose ENTR to confirm your selection Target Volume or Time screen choose ENTR to confirm your setting
62. f gt seconds lt cr gt lt f gt lt prompt gt or lt I HH HH HH HH lt Cr gt lt lf gt lt prompt gt TTIME Sets or displays the target time Quick Start mode only Command format ttime target time Query response lt f gt Target time not set lt cr gt lt f gt lt prompt gt or lt lf gt seconds lt cr gt lt f gt lt prompt gt or JE SHEHER lt C gt lt lf gt lt prompt gt WTIME Displays the withdrawn time Quick Start mode only Command format wtime Query response lt f gt seconds lt cr gt lt f gt lt prompt gt or JE 3 HHE HERE HH lt cr gt lt f gt lt prompt gt Cole Parmer Touch Screen Series Syringe Pump User s Manual Publication 5607 009 REV B Operating the Cole Parmer Touch Screen Series Digital I O commands INPUT Reads and displays the trigger input port status Command format input Query response lt f gt The trigger input is low lt cr gt lt f gt lt prompt gt or lt lf gt The trigger input is high lt cr gt lt lf gt lt prompt gt OUTPUT Sets the level on one of the output ports Command format output 1 2 high low SYNC Sets the level on the sync port Command format sync high low Internal commands STATUS Displays the raw status for use with a controlling computer Command format status The output is in three integer fields and one flag field all se
63. f range First rate is out of range Second rate is out of range First time is out of range Second time is out of range First volume is out of range Second volume is out of range The of pulses is O enter a number larger than O Bad memory sector in step d Step was deleted Target volume exceeds syringe capacity in step d Change the target volume Incompatible rates vs syringe size in step d Change either the rate or the syringe size The of repeats is O enter a number larger than 0 Go To cannot link to itself Select another step Cole Parmer Touch Screen Series Syringe Pump User s Manual Publication 5607 009 REV B Operating the Cole Parmer Touch Screen Series Critcal Errors ERROR 401 ERROR 402 ERROR 403 ERROR 404 ERROR 405 Notice NOTICE NOTICE NOTICE NOTICE NOTICE NOTICE NOTICE NOTICE NOTICE NOTICE NOTICE NOTICE NOTICE NOTICE phone 800 323 4340 fox 847 247 2929 email infoOcoleparmer com web www coleparmer com Infuse rate could not be saved to disk Contact factory Withdraw rate could not be saved to disk Contact factory Program step could not be saved to disk Contact factory Program could not be read from disk Contact factory Program step could not be read from disk Contact factory The display is locked Press the lock button twice to activate the touch screen Deleting program Importing new
64. ge Pump User s Manual Publication 5607 009 REV B Product Overview 13 OPERATING INSTRUCTIONS Half nut Release Knobs Pusher Block Syringe Barrel Clamp Guide Rods Syringe Holder Bracket Clamp Knobs Run LED Lead Screw User Interface Touchscreen Protective Antiglare and EMI Shield RS232 Serial Input RS485 Connection Pump to Pump USB Serial Input Type B C o E O m 3 D O C O e C C D D C ANALOG IN 10V FOOT USB 85 232 RS 485 SWITCH Foot Switch gt DIGITAL 1 0 RoHS Compliant Oy Directive 2002 95 EC e eee gt INTO HUE WE 99292909 qua E o no o o SAUTION eo 999 o I O C t O Connector amp i TOSA 250V POWER 91 19 Main Power Switch WEE Cole Parmer Menag enara my nw Fuse Holder Serial Number Analog In Label Option POWER CONNECTIONS 1 Plug the power cord in The Cole Parmer Touch CAUTION Do not connect to Screen Series has a universal power input connector firewire ports on a computer on the rear of the unit The operating range for the Damage may occur to the Cole Parmer Touch Screen Series series is 100 pump or computer 240 VAC 50 60 Hz 2 Turn on the main power switch NOTE Remove tab under battery cover 2 to activate battery back up of date and time in the pump phone 8 0 0 3
65. get volume S Press to select target time Press to select the maximum volume for the syringe size selected BACK IM ENTR 4 In the Units Selection Display select the Units Selection 06 25 09 8 21 56 AM volume units Current selection ml BACK I ENTR cl phone 8 0 0 3 2 3 43 40 fax 847 247 2929 Cole Parmer Touch Screen Series Syringe Pump User s Manual email infoOcoleparmer com web www coleparmer com Publication 5607 009 REV B pa Cole Parmer Delivering Solutions You Trust_ Configuring the Cole Parmer Touch Screen Series 19 Previewing the Configuration Configuration 10 30 09 02 02 42 AM It is simple to view the Pump Configuration on the RUN display P P Conti ti KDS Glass ress o view Pump Configuration 10 008 SETUP After you have verified the configuration wi Press to run the displayed configuration wc ERE O O Press to preview configuration Run 10 30 09 02 11 41 AM 2 MODE Infuse Only 36 003 ml min SYRINGE KDS Glass 10 ml FORCE LEVEL 100 TARGET 5 mi E EL 0000 mi INFUSION TIME 00 00 08 FLOW DIRECTION Te SETUP TIME ELAPSED 00 00 00 TIME REMAINING 00 00 08 STATUS READY TO INFUSE Lis TOTAL INF VOLUME 0 ml Configuring the Pump s Configuration 10 30 09 02 02 42 AM M EC Infuse Only The pump has basic parameters that should be configured during initial startup Once these parameters are entered they probably won t be changed denn To enter the set up
66. have the continuous mode selection Press to toggle on off Infuse Withdraw models only Continuous flow is an option on the display In continuous mode the pump will infuse then withdraw continuously or vice versa depending on which mode is selected The pump will switch to withdrawal based on the target volume entered The total infuse volume will be displayed on the run screen as well as total elapsed time Configuration KDS Glass 10 00mi 10 30 09 02 02 42 AM SYRINGE RATES 36 003 ml min vor EN Configuration 10 30 09 02 00 39 AM CONT mE Infuse Withdraw FLOW KDS Glass SYRINGE 10 00m1 36 003 ml min RATES W 20 miZmin wi o 01 Vol E O mi Mode Selection In the Configuration Display select mode available modes depend on the pump model e Infuse e Withdraw Infuse Withdraw e Infuse Withdraw continuous e Withdraw Infuse e Withdraw Infuse continuous e Custom program The Mode Selection Screen will be displayed The available modes will be displayed based on the model of syringe pump Press the Mode to select Configuration 10 30 09 02 02 42 AM Infuse Only KDS Glass SYRINGE me RATES 36 003 ml min Volume TARGET am Mode Selection Infuse Only 10 02 09 8 25 46 AM Infuse Withdraw Withdraw Infuse 1_PROGRAM Program a 1 je M Program e ga OO iH 15 phone 800 323 4340 fox 847 247 2929 email info coleparmer com w
67. hese optional accessories provide the necessary brackets to hold up to four 140 ml syringes or six 10 ul syringes Also the user can use the microliter rack which has been specifically designed for smaller syringes The programmable models offer maximum flexibility and capability for configuring and running different programs Up to 40 programs of 20 steps each can be configured and stored in the unit and recalled quickly with the touch of a button The programs are identified with a 15 character alphanumeric name for easy identification and can be stored on the computer and downloaded at future dates A real time clock is available to start and stop programs based on time Extensive programming options allow the user to duplicate configurations append one configuration to another rename programs delete programs export programs to a PC or export a program to another pump This feature can ensure consistency and accuracy of multiple pumps Preprogrammed profiles are selectable from Constant Rate Ramp Stepped and Pulse These standard profiles make configuration easy to set up If more complexity is needed the user can select from advanced programming options including Go To statements Time delays Repeating steps e Linking different programs Stopping the pump e Triggering the pumps TTL output Accepting an event input in such as a user touch motor stall e Events can trigger the pump to withdraw or infuse phone
68. hone 8 0 0 3 2 3 A3 40 fax 847 247 2929 Cole Parmer Touch Screen Series Syringe Pump User s Manual email infoOcoleparmer com web www coleparmer com Publication 5607 009 REV B Operating the Cole Parmer Touch Screen Series 48 I O EVENT TRIGGERS The Cole Parmer Touch Screen Series pump permits easy connection to external O devices via a variety of interfaces including a built in 15 pin D sub connector The Cole Parmer Touch Screen Series software incorporates simple commands for incorporating O controls into your pump Programs Integrated commands for control of an external valve multi pump synchronization and general trigger signals are integrated in the software The following procedure describes the use of the Advanced Options I O commands Following the procedure is a description of the selection menu options for each of the I O command types Details for the electrical connection controls and pin out description for the 15 pin User I O Connector are provided in Appendix D of this manual The Cole Parmer Touch Screen Series manages trigger events through specific pins on the I O Connector port on the back of the pump The following details define pin logic e Triggers are communicated via Pin 4 or Pin 5 Valve control signals are communicated via Pin 8 e Pump synchronization commands are communicated via Pin 6 Event signals are communicated via Pin 2 44 Cole Farmer phone 8 0 0 3 2 3 43 40 fax 847 24
69. i Syringe Clamp Knob into the threaded bar attached to the Multi Holder A Cole Parmer hone 8 0 0 o 3 2 3 43 40 fax 847 247 2929 Cole Parmer Touch Screen Series Syringe Pump User s Manual Delivering Solutions You Trust P email info coleparmer com web www coleparmer com Publication 5607 009 REV B Appendices 72 Syringe Loading 4 x 140 amp 6 10 Multi Racks 1 Raise or remove Clamp Bar 6 by unscrewing thumb screw 9 2 Loosen T Knobs 7 located under the Syringe Holder 2 and slide the Retaining Bracket 3 on the Syringe Holder open 3 Adjust the Pusher Block to the approximate length of the syringe s by squeezing the Release Tabs 1 and sliding the Pusher Block into position C o E O m 3 D O C O gt e C C D D C 4 Loosen the three thumb screws on the Anti Syphon Bar 4 to provide enough room for the plunger flange of the syringe s If using the 6 10 rack loosen the two thumb screws on the outside of the Plunger Holder 8 Flip the Plunger Holder open 4 x 140 Multi Rack 91 19 5 Place the syringe s on the Syringe Holder 2 ensuring that the barrel flanges are within the Syringe Holder s Retaining Bracket 3 and the plunger flanges are between the Pusher Bar 5 and Anti Syphon Bar 4 NOTE f using fewer syringes than the 2 maximum number of syringes try to place them symmetrically about the lead screw to present a balanced load
70. ic Output active low low run connect to LED Cathode Electrical Specifications Inputs VIH gt 2V IIH lt 20uA VIL lt 0 4V liL lt 0 5mA Outputs VOH 2 3 8V IOH lt 6mA VOL lt 0 4V IOL lt 6mA Y phone 8 0 0 3 2 3 A3 40 fax 847 247 2929 Cole Parmer Touch Screen Series Syringe Pump User s Manual email infoOcoleparmer com web www coleparmer com Publication 5607 009 REV B Appendices 78 Analog Input Option Analog Control Time and date not set ANALOG MODE Ls Speed 0 Signal Description GND Ground IN SIG RTN Signal RTN N C IN ANALOG IN 0 10 V Analog In ANALOG IN SIG O to 10V OVERVOLTAGE RATING Absolute Max Min 15V Max 2 5V Min Analog control of the motor speed can be achieved in many ways The following circuit is recommended A DC voltage 10 VDC max will be needed to supply the excitation voltage to the circuit DC Voltage Source Mating 10 VDC max Connector Multi turn Potentiometer a Ge Pump Refer to the accessories DC Voltage Source section for recommended mate connector and Return sable Connect cicuit as shown in the above figure Turning the Potentiometer CW will increase the motor speed pin 4 is 10 VDC and turning the Potentiometer CCW will decrease the motor speed pin 4 is O VDC recommended mate connector and cable Pw NOTE Refer to the accessories section for Y phone 8 0 0 3 2 3 43 40 fax 847 247 2929 Cole Parmer Touch
71. ify its compatibility with Windows XP Tell me why this testing is important Continuing your installation of this software may impair or destabilize the correct operation of your system either immediately or in the future Microsoft strongly recommends that you stop this installation now and contact the hardware vendor for software that haz passed Windows Logo testing Continue Anyway l penguen 5 The Virtual Commport software will be installed When the software installation is complete click Finish to close the wizard Completing the Found New Hardware Wizard The wizard has finished installing the software for E Syringe Pump XP Vista m Click Finish to close the wizard NY phone 8 0 0 3 2 3 43 40 fax 847 247 2929 Cole Parmer Touch Screen Series Syringe Pump User s Manual email infoOcoleparmer com web www coleparmer com Publication 5607 009 REV B Appendices 81 RS 232 Specifications RS 232 9 Pin D SubMale Baud Rates 9600 19200 38400 57600 115200 Word size 8 Parity None Stop Bits 2 RS 232 Specifications T4 phone 8 0 0 3 2 3 43 40 fax 847 247 2929 Cole Parmer Touch Screen Series Syringe Pump User s Manual e mail infoOcoleparmer com web www coleparmer com Publication 5607 009 REVB Appendices 82 RS 485 CAUTION DO NOT CONNECT TO FIREWIRE PORTS ON A PC DAMAGE MAY OCCUR TO PUMP AND OR PC Mating Face RS 485 In Signal RS 485 Out Signal Notes PW
72. in a display list Insert Step Used to insert a new Step in a Program while editing creating the Program The new Step is inserted after the Step that is currently selected Delete Step Used to delete the selected Step in a Program while editing creating the Program To confirm deletion you must select the Delete Step button a second time Move Step Up Moves the currently selected Step in a Program up one position in the Program Order e g Step 3 becomes Step 2 Move Step Down Moves the currently selected Step in a Program down one position in the Program Order e g Step 2 becomes Step 3 Copy Step Creates a duplicate copy of the currently selected Step in a Program and inserts it as the last Step in the Program being created edited Password Protecton Off Indicates that the pump is currently unlocked Pressing the button twice locks the Touchpad Password Protection On Indicates that the pump is currently locked Press the button and enter password to unlock the pump settings screen File Options Access the File Options menu that is used to manage the list of Programs and to export Program information to an externally linked pump or to a connected computer Cole Parmer Touch Screen Series Syringe Pump User s Manual Publication 5607 009 REV B C o E O m 3 D O C O e C C D D C 91 19 TS Cole Parmer Selecting An Item From a Menu List Selecting
73. iner Bracket Micro Syringe Holder dd 2401 081 Bracket Syringe lamp 2401 050 o Dual Syringe Holder 2402 007 Syringe Holder Assembly 1 Remove Syringe Clamp and knob from the Syringe Holder 2 Remove two set screws from the Dual Syringe Holder with the provided Hex Key 3 Place the assembled Micro Syringe Holder onto the dual syringe holder and screw in the two Standoff Bars 2 4 Place the Clamp Bar Assembly onto the Micro Syringe Holder and push and screw the Thumbscrew Caps 2 into the Standoff Bars 44 Cole Farmer phone 8 0 0 3 2 3 A3 40 fax 847 247 2929 Cole Parmer Touch Screen Series Syringe Pump User s Manual email infoOcoleparmer com web www coleparmer com Publication 5607 009 REV B Appendices 75 Syringe Loading Micro Liter Multi Rack Front view of Cole Parmer Touch Screen Series showing controls for micro liter multi rack syringe loading C o E Q m 3 D O C O e C C D D C l Squeeze Release Tabs 1 and adjust the Pusher 6 Lower the bumpers 10 until they are firm against Block 2 to the approximate length of the the syringe s by screwing in the Screw Cap 6 D TORE 7 Push the Syringe Holder s Retaining Bracket 7 m 2 Loosen the Retaining Bracket 3 on the Pusher tight against the barrel flange and tighten into o Block 2 by unscrewing the Bracket Clamping place using the T knobs 9 Then push the Pusher Y Knobs
74. ist of available numbers and symbols that can be included in the Program Name To switch the keyboard back to letters mode choose the Letters button ABC 15 characters maximum 5 When finished entering the new Program Name choose Accept to save your changes and return to the File Options screen 6 Choose BACK to return to the Mode Selection screen Selection screen 32 phone 800 323 4340 fox 847 247 2929 email infoOcoleparmer com web www coleparmer com Cole Parmer Touch Screen Series Syringe Pump User s Manual Publication 5607 009 REV B pa Cole Parmer Delivering Solutions You Trust_ Operating the Cole Parmer Touch Screen Series Appending A Program Follow these instructions to Append a previously created Program into a new Program 1 From the Program Configuration screen choose the Program Name button to enter the Mode Selection screen 2 From the list of available Programs select press once the Program you want as the base Program 3 Choose the File Options button to enter the File Options screen 4 Choose Append to access the Program to Append screen 5 Choose press twice the Program you would like to Append attach to your base Program The pump will return you to the File Options screen and display a confirmation that the Program was copied 6 Choose BACK to return to the Mode Selection screen phone 800 323 4340 fox 847 247 2929 email infoOcolep
75. its calibration due date Cole Parmer Touch Screen Series Syringe Pump User s Manual Publication 5607 009 REV B Configuring the Cole Parmer Touch Screen Series 22 For Near End of Run Selection Select the volume dispensed For example if you select 80 the pump will sound an alarm 3 Near End of Run short beeps when the 80 of the volume is dispensed Accept the changes made by pressing ATI 07 21 09 11 21 33 AM and go back to the Set up screen Cancel the changes made by pressing and go back to the Set up screen Press to select i BACK I ENTR volume dispensed H B O For a Custom Near End of Run 07 21 09 11 21 33 AM Use this selection if the is not listed Press Other Value to enter a custom Accept the changes made by pressing FAT and go back to the Set up screen Cancel the changes made by pressing and go back to the Set up screen BACK M ENTR Other Value Press to enter a custom Enter the percentage Set Near End of Run Alarm 08 24 09 9 19 34 AM Accept the changes made by pressing Fim Percent Done b and go back to the Set up screen Cancel the changes made by pressing and go back to the Set up screen BACK IM ENTR cl phone 8 0 0 3 2 3 43 40 fax 847 247 2929 Cole Parmer Touch Screen Series Syringe Pump User s Manual e mail infoOcoleparmer com web www coleparmer com Publication 5607 009 REV B Configuring the Cole Parmer Touch Screen Series
76. ly Popper amp Sons Plastic Size Diameter Size Diameter MICRO MATE Glass Size Diameter 2 5 ml ABS mm 5 ul 0 343 mm Size Diameter 1 ml 4 674 mm 9 525 10 0 485 0 25 ml 3 47 mm 3 8 865 20 1913 25 0 729 0 5 3 62 6 12 600 50 28 6 50 1 03 1 4 82 12 15 621 100 34 9 100 1457 2 89 20 20 142 250 2 303 3 89 35 23 571 R 500 3 257 5 11 71 60 26 568 Air Tite HSW Norm Ject 1 ml 4 606 mm 10 14 65 140 37948 Size Diameter 25 7 284 20 19 56 1 ml 4 69 mm 5 10 301 30 227 Hoshi 2 5 9 65 10 14 567 50 28 02 iz Diameter 5 12 45 25 23 100 35 7 E I eae 10 15 9 50 27 5 2 9 10 20 20 05 100 35 Becton Dickinson 3 10 00 50 29 2 Hamilton Glass pl yee 10 15 10 a All Tubes Size Diameter 20 20 45 Becton Dickinson YP 0 5 ml 4 64 mm 30 22 50 Plasti pak Size Diameter 4 64 50 25 60 CT pa 0 5 ul 0 103 mm 2 5 8 66 i Size Diameter 1 0 146 5 11 86 100 34 00 1 ml 4 699 mm 2 0 206 10 14 34 3 8 585 5 0 343 20 19 13 Natsume 5 11 989 10 0 485 30 207 Size Diameter 10 14 427 25 0 729 50 28 6 0 25 ml 2 5 mm 20 19 05 20 1 03 100 34 9 0 50 2 8 30 21 59 100 1 457 1 4 0 50 26 594 250 2 304 KD Scientific Glass 2 6 2 60 26 594 500 3 256 Si 3 7 4 ize Diameter 1 ml 4 608 mm 1 ml 4 80 mm 5 9 2 Terumo 125 5 151 gt 645 Size Diameter 2 5 7 285 5 12 60 Top 1 mi 4 70 mm 2 10 3 10 15 50 Size Diameter 3 8 95 mm 10 14 567 20 20 40 1 ml 6 40 mm 5 13 25 23 033 30 22 90 2 5 9 30 10 15 8 50 32 573 50 2745 5 13 10 20 20 15 100 32 573 100 35 90 10 15 3 30 23 1 150 34 20 20 21 0 60 29 1 30 2
77. mp will continue the interrupted procedure where it stopped 4 Out of Range A value was entered or encountered in a pump program that was beyond the pump s limits 5 Power Failure Notification If power to the pump is interrupted during operation an alarm will sound to alert the user to the interruption When power is restored an onscreen message is displayed to indicate the interruption 6 Low Battery Indication Time Date area will turn red when battery is low see Appendix E for instructions on changing the battery ES Cole Parmer hone 8 0 0 o 3 2 3 43 40 fax 847 247 2929 Cole Parmer Touch Screen Series Syringe Pump User s Manual Delivering Solutions You Trust p email info coleparmer com web www coleparmer com Publication 5607 009 REV B APPENDIX F AUTO FILL VALVES There are two Auto Fill Valve models available Item No Description 74905 70 Standard Pressure Supplied with 1 8 inch ID 1 4 inch OD silastic tubing and connector to syringe 74905 71 High Pressure Supplied Swagelok fittings 74905 81 Adapter Digital O Setting Up the Valve Set up consists of three phases Power Connection Pump to valve electrical connection and Valve tubing to syringe hook up 1 Power Connection Connect the line cord to the power supply included Attach the power supply to the input jack on the valve box 2 Pump to Valve Electrical Connection The cable fitted with a male 9 pin D sub connec
78. mpt gt Prompt see below The following prompts are returned after a command is executed The pump is idle gt The pump is infusing lt The pump is withdrawing The pump stalled i The target was reached If the pump is in poll mode an XON character is added after the prompt If the pump address is nonzero the pump address is prefixed to the prompt without a colon In the following list of commands The pump address is prefixed to every response line followed by a colon lt f gt lt prompt gt is the response unless otherwise noted Error messages Error messages are displayed if the entered command cannot be executed for some reason The error message will take up two lines with the first line being the message type and the second line describing the error itself The second line may be up to 80 characters long Cole Parmer Touch Screen Series Syringe Pump User s Manual Publication 5607 009 REV B pa Cole Parmer Delivering Solutions You Trust Operating the Cole Parmer Touch Screen Series Command errors Command errors are displayed when the command is unrecognized entered in the wrong mode or the state of the pump keeps the command from executing i e using the IRUN command if a limit switch is active The command error has the following format lt f gt Command error lt cr gt lt lf gt lt sp gt lt sp gt lt sp gt error message lt cr gt lt lf gt lt prompt gt
79. n Choosing the Go To Command brings you to a listing of the available steps in the Program 6 Double tap the Step that you want to jump to with the Go To Command The system automatically returns to the Step Definition screen which now shows the Go To Step inserted in the Program Cole Parmer Touch Screen Series Syringe Pump User s Manual Publication 5607 009 REV B pa Cole Parmer Delivering Solutions You Trus _ Operating the Cole Parmer Touch Screen Series Delay The Delay Command is used to insert a time delay in a procedure You can program a time delay between 0 2 seconds up to 99 99 99 99 hours 99 minutes 99 seconds TO INSERT A TIME DELAY IN A PROGRAM l From the Program Main screen choose Step Definition to enter the Step Definition screen 2 Highlight select once the Program Step that you want the time delay to follow 3 Choose the Insert Step button to access the Program Steps Menu screen 4 Choose Advanced Options to enter the Set Advanced Options screen 5 Choose Delay to enter the Set Delay Time screen Set Delay Time Coe 08 24 09 10 14 10 AM Ya EJ El EI F3 EI Tole Fi Ba Advanced Options Set Delay Time screen 6 Enter the desired Time using the keypad 7 Ifthe Units of Time associated with Time are not correct for your application select the Units button to toggle between sec seconds 0 2 seconds minimum allowable value and h m s hours minutes seconds
80. n Ei ar D leling a Step roma Programi NT 37 Duplicais a Seb Ma rogir a sae EE E TOT 37 Pump Operai on PONES erer innn EA a A A N N ENE E 38 CON ONO rats 39 SA 40 Sepped ce esas 41 A A A O EORUM 43 Ad Cole Farmer phone 800 323 4340 tax 847 247 2929 Cole Parmer Touch Screen Series Syringe Pump User s Manual email infoOcoleparmer com web www coleparmer com Publication 5607 009 REV B Table of Contents 4 SUBJECT PAGE NO Incorporating Advanced OPA rss 44 EON A E o 44 Dela ya a E E E E E peta 46 o A E E E E E 46 A E A A E E E 47 A ooo A 47 VO Even IES e E T M 48 Jem IC e CO EENEN E ANNA 49 I O Event A 50 I O On Event IN is B Managing Cole Parmer Touch Screen Series Programs esses 52 Saving a Copy ol a Progra ea 92 Fe SECM Cl TO GRO E E EO o LO 52 Appendini A Prr TE TT 53 Deleting a Programi lens T 53 Program Import ana EXPO sereen N 54 Transfer a Program between Pumps ee ee eae nea ne er een ee 54 Exporting a Program to an External Oni ETT pecera DO Importing a Program from an External Computer cct ette tert enean wer vocet 55 External Pump Control sese tnter tnter nnn 20 ln 56 Pamp Chair o ct race sc zene tate nnr EOE EE EEEE E annin 57 A S NNI ee E ee eee eee 58 EES E E EET 60 A a 60 Volume Connan eaaa eee ane eee eae ee ene ee ee ee ae re ee 6 Time C ONES ooo ocio oie 62 Digital O dee M OT 63 Igo Eo NERO ee ee ee eee ere eee 64 44 Cole Farmer phone 800 323 4340 tax 8
81. nced Click Next to continue NY phone 8 0 0 3 2 3 43 40 fax 847 247 2929 Cole Parmer Touch Screen Series Syringe Pump User s Manual email infoOcoleparmer com web www coleparmer com Publication 5607 009 REV B Appendices 80 USB VIRTUAL COMMPORT DRIVER INSTALLATION CONTINUED Found New Hardware Wizard Please choose your search and installation options D Search for the best driver in these locations Use the check boxes below to limit or expand the default search which includes local paths and removable media The best driver found will be installed Search removable media floppy CD ROM IV Include this location in the search fe USER BHE ProjectsNS yringePumps Browse C Don t search will choose the driver to install Choose this option to select the device driver from a list Windows does not guarantee that the driver you choose will be the best match for your hardware 3 Browse for the proper USB driver installation folder in the USB folder and then click next It can be found on the CD supplied with the Cole Parmer Touch Screen Series Pump USB Driver WindowsXP or Vista USB Driver Windows2000 EN 4 If a warning message regarding Windows Logo testing is displayed choose Continue Anyway to proceed with the installation Hardware Installation The software you are installing For this hardware Syringe Pump Pista has not passed Windows Logo testing to ver
82. nd Withdraw Rate screens TO SET UP EDIT A RAMP RATE PROFILE 1 From the Step Definition screen for a Ramp Rate profile choose the Direction button to toggle the Flow Mode between Infuse and Withdraw operation Step 4 Ramp Infuse gt lt Start 0 ml min 07 21 09 12 16 39 PM End O ml min 0 second s BACK I ENTR Step Definition screen for a Ramp Rate profile phone 800 323 4340 fox 847 247 2929 email info coleparmer com web www coleparmer com 2 Set Start and End Rate Start Rate 40 Choose the Set Start amp End Rate button to enter the Set Start amp End Rates screen 08 24 09 10 07 09 AM o ml min ear orn 8 9 BACK I ENTR Set Start and End Rates screen Select the Start Rate button it should be selected by default as indicated by the active data entry box to the right of the button Enter the flow rate value desired using the keypad or select the Minimum Rate or Maximum Rate button IF the Units of Rate are not correct for your application choose the Units button On the Units Selection screen select the unit of measure ml ul nl or pl and the unit of time sec min hr as appropriate then choose ENTR to confirm your selections Repeat Steps 3 to 5 for the End Rate by selecting the End Rate button and continuing data entry When all parameters are correctly set on the Set Rate screen choose ENTR to confirm your settings and retu
83. nges Secure the syringe flanges by pushing the retaining brackets 4 5 tightly against the syringe flanges using the bracket clamping knobs 7 8 The syringe plunger should be secured by the pusher block retaining bracket and the flange of the syringe should be secured by the syringe holder block retaining bracket Tighten the mechanical stop collars 9 on the pump to prevent excess pusher block travel NOTE The syringe barrel clamp 10 2 may need to be flipped depending on your syringe size To do so completely unscrew and remove the syringe barrel clamp knob trom the syringe block Then remove lock nut 11 Flip the bracket and reassemble prevent the DR trom are ming out on glass syringes NOTE For infuse withdraw models make sure the plunger is secured in the retaining bracket and the barrel of the syringe is secured in the retaining bracket Cole Parmer Touch Screen Series Syringe Pump User s Manual Publication 5607 009 REV B C o E Q m 3 D O C O e C C D D C 91 19 Configuring the Cole Parmer Touch Screen Series Configuring the Cole Parmer Touch Screen Series The Cole Parmer Touch Screen Series program is easy to set up The Cole Parmer Touch Screen Series is easily configured When the unit is powered up the Configuration Screen will be displayed If you select infuse withdraw or withdraw infuse mode the configuration screen will
84. ntrol Cable 74905 60 Infuse Withdraw 6 10 Multirack dla ORSPISGSIETI SUNG Six 30 to 60 ml syringes or ten 0 5 ul 74905 98 Replacement Battery 74905 61 74905 62 74905 70 74905 71 74905 72 74905 73 74905 74 74905 75 74905 76 74905 77 74905 78 74905 79 74905 80 74905 81 74905 82 74905 83 74905 84 74905 85 74905 86 to 20 ml syringes can be sold for Infuse Only as well Infuse Withdraw 4 x 140 Multirack Four 60 to 140 ml syringes can be sold for Infuse Only as well Infuse Withdraw Microliter Rack Four 0 5 ul to 10 ml syringes can be sold for Infuse Only as well Auto Fill Valve Box Low Pressure Auto Fill Valve Box High Pressure Anti Siphon Kit RS485 Pump to Pump Communication 5 m RS485 Pump to Pump Communication 2 m USB Cable PC to Pump Communication 2 m USB Cable PC to Pump Communication 5 m RS232 Cable 9 pin d sub 2m Line Cord US 115 V Line Cord European Line Cord UK Adapter Digital I O 15 pin to 9 pin Adapter D Sub 15 to Terminal Block Footswitch with Phono Jack Plug Adapter for 25 ml 50 ml 100 ml Hamilton Gastight Syringe Hex Key Lubricant SuperLube 1 cc Only available with 74905 54 74905 58 phone 800 323 4340 fox 847 247 2929 email infoOcoleparmer com web www coleparmer com Cole Parmer Touch Screen Series Syringe Pump User s Manual Publication 5607 009 REV B pa Cole Parmer Delivering Solutions You Trust Declaration of Conformity Manufactur
85. ocks Avoid placing fingers between these points while the pump is running DO NOT OPERATE WITH SUSPECTED FAILURES If damage is suspected on or to the product do not operate the product Contact qualified service personnel to perform inspection ORIENT THE EQUIPMENT PROPERLY Do not orient the equipment so that it is difficult to operate the disconnection device PLACE PRODUCT IN PROPER ENVIRONMENT Review the operating manual for guidelines for proper operating environments OBSERVE ALL WARNING LABELS ON PRODUCT Read all labels on product to ensure proper usage CAUTION Refer to Manual Protective Ground Terminal Y phone 8 0 0 3 2 3 43 40 fax 847 247 2929 Cole Parmer Touch Screen Series Syringe Pump User s Manual email info coleparmer com web www coleparmer com Publication 5607 009 REV B General Information WARRANTY AND REPAIR INFORMATION Manual Description This manual is designed to provide all operational and program information required to operate and maintain the Cole Parmer Touch Screen Series syringe pumps The functions and features are described in the Technical Specifications section Warranty The Cole Parmer Instrument Company warrants this product to be free from significant deviations in material and work manship for a period of one year from date of purchase If repair or adjustment is necessary and has not been the result of abuse or misuse within the one year period please return f
86. of the button Enter the desired operation value using the keypad Step 1 Stepped 08 24 09 11 48 41 AM 10 If the Units of Time are not correct for your vum application select the Units button to toggle between sec seconds and h m s hours minutes seconds To use the h m s option Start O ml min End O ml min enter your time value in hours minutes and seconds separating each value with a colon 0 second s 0 Stepls 11 Select the Number of Steps button and enter the desired value using the keypad 12 When all parameters are correctly set on the Set Time and Steps screen choose Accept to confirm Step Definition screen for a Stepped Profile your settings and return to the Stepped Definition screen 2 Choose the Rates button to enter the Set Start and End Rates screen Set Start and End Rate 08 24 09 10 07 09 AM Start Rate lo End Rate o BACK I ENTR Set Start and End Rate screen 3 Select the Start Rate button it should be selected by default as indicated by the active data entry box to the right of the button Enter the flow rate value desired using the keypad or select the Minimum Rate or Maximum Rate button 4 If the Units of Rate are not correct for your application choose the Units button 5 On the Units Selection screen select the unit of measure ml ul nl or pl and the unit of time sec min hr as appropriate then choose Accept to confirm your selections 6 Repeat Step
87. older p Dni Installing a Syringe Repositioning the Adjustable Syringe Holder 1 Loosen Thumbscrews 1 to release the Retaining For syringes gt 60 ml Brackets 2 amp 3 located on the Floating Syringe Holder Aland Pusher Block 5 For larger syringes you will need to detach the Floating Syringe Holder and then mount it on the outside of the C 22 P ET Q m D O Cc O gt N O D D C 2 Loosen Syringe Clamp 6 by unscrewing the Stationary Syringe Holder Syringe CI Knob 7 yringe Clamp Knob 7 l Loosen the two Thumbscrews 1 on the Stationary 3 Place the syringe s under the Syringe Clamp on Syringe Holder 9 and slide the Retaining Bracket the Floating Syringe Holder Ensure that the 2 forward syringe s flanges are within the Retaining Brackets 91 19 2 Remove the two Locking Pins 8 4 Lock the flanges into place by tightening the Retaining Brackets using the Thumbscrews VE Removes eating syanga holder 14 4 Place the Floating Syringe Holder on the outside 5 Tighten the Syringe Cl ing the Syri ede ial E ea ll of the Stationary Syringe Holder and lock into CI Knob A place using the Locking Pins Repositioning the bracket location 5 Slide the Retaining Bracket back and tighten using 1 Unscrew the syringe clamp completely the Thumbscrews 2 Push the knob out of the clamp 3 Reposition and or flip over and then push the knob back into the clamp 44 Cole Farmer
88. oose the Time or the Volume button to enter the Set Pulse Times or the Set Pulse Volumes screens phone 800 323 4340 fox 847 247 2929 email infoOcoleparmer com web www coleparmer com Set Pulse Times 44 08 24 09 10 09 02 AM E El OA El El 10 11 12 14 13 16 BACK MM ENTR Set Pulse Times screen used to define the length of time the pump will operate at each pulse step level IFyou selected Set Time continue with Step 11 IFyou selected Set Volume proceed to Step 14 On the Set Pulse Times screen select the Time 1 button it should be selected by default as indicated by the active data entry box to the right of the button Enter the desired value using the keypad Repeat for Time 2 If the Units of Time associated with Time 1 or Time 2 are not correct for your application select the Units button associated with either parameter to toggle between sec seconds and h m s hours minutes seconds To use the h m s option enter your time value in hours minutes and seconds separating each value with a colon When both Time parameters are set to the correct values choose the Accept button to return to the Pulse Definition screen Continue with Step 17 On the Set Pulse Volumes screen select the Volume 1 button it should be selected by default as indicated by the active data entry box to the right of the button Enter the desired value using the keypad Repeat for Volume 2 If the
89. p running when power resumes NOTE This feature is only valid in Infuse BZ Only or Withdraw Only modes This feature will only execute if the pump is running at the time when power is lost and was running with no target set In the Set up screen select Resume Run After Power Loss ati Accept the changes made and go back to the previous screen before Set up mode was selected Cancel and go back to the previous screen before Set up mode was selected 27 08 24 09 9 17 18 AM BACK MM ENTR Press Here NOTE Elapsed Timers and Total Infused Volume will be reset when power resumes Counters and timers information prior to loss of power are lost Setting and Viewing Pump Information The information on the pumps parameters are displayed in the Pump Information Screen In the Set up screen select Pump Information The current information on the pump will be displayed The Model type The Software Version e The of program steps used out of the of program steps available e The Calibration Due Date e The Maintenance Due e The Current Pump Address Press Calibration Reset to reset the calibration date one year from current date Confirm the Calibration Reset by pressing the Calibration Reset again Press Maintenance Reset to reset the of hours for maintenance This will reset it to 100 hours Confirm the Maintenance Reset by pressing the Maintenance Reset again e Accept the changes made by
90. p to a target volume or for a defined time period Target Time or Total Volume Point Flow Rate Time Volume Constant Rate Pump Operation Profile When creating or editing a Constant Rate profile you will define three primary operating parameters e The Flow Mode defining the direction of flow infuse or withdraw e The Flow Rate to define the rate of uptake or dispensing e The Target Volume or Run Time that determine how long the pump will operate at the set rate When creating or editing a Constant Rate profile you can set the rate in ml ul nl or pl units of volume using sec min or hr as the units of time The system automatically calculates a minimum and maximum flow rate based on the syringe selected or custom defined The min max values are made available as button selection options on the Set Infuse and Withdraw Rate screens Step 4 Constant Rate 07 21 09 12 13 28 PM Infuse O ml min BACK I ENTR Constant Rate Profile Setup Screen phone 800 323 4340 fox 847 247 2929 email infoOcoleparmer com web www coleparmer com 39 TO SET UP EDIT A CONSTANT RATE PROFILE l From the Step Definition screen for a Constant Rate profile choose the Direction button to toggle the Flow Mode between Infuse and Withdraw operation Choose the Rate button to enter the Set Rate screen Enter the flow rate value desired using the keypad or select the Minimum Rate or Maximum Rate button IF the Units o
91. p to wait for manual input from the user at the touchscreen screen touch phone 800 323 4340 fox 847 247 2929 email infoOcoleparmer com web www coleparmer com 50 TO INSERT AN I O IN EVENT COMMAND l From the Program Main screen choose Step Definition to enter the Step Definition screen Highlight select once the Program Step that you want the I O IN Event to follow Choose the INS STEP button to access the Program Steps Menu screen pe Choose Advanced Options to enter the Select Advanced Options screen Choose the O IN Event button to enter the Event Step Definition Screen Select either Input High Input Low or User Press as appropriate Choose the Accept button to save your changes and return to the Step Definition screen Cole Parmer Touch Screen Series Syringe Pump User s Manual Publication 5607 009 REV B pa Cole Parmer Delivering Solutions You Trust_ Operating the Cole Parmer Touch Screen Series I O IN Event Link The I O IN Event Link command is used to have the pump jump to a linked program if the signal is received The external signals are communicated via Pin 2 on the 15 pin I O Connector On Event 08 24 09 1 28 52 PM Input High to Low lI Input Low to High Motor Stall User Press Withdraw Infuse BACK I ENTR Advanced Options I O IN Event Link Selection Screen The following options are available when setting an I O IN Event Link comman
92. parated by spaces and terminated by a carriage return linefeed pair The first integer is the current rate in femtoliters per second The second integer is the infuse time in clock cycles One clock cycle is 1 56 000 000 second The time has a granularity of 1 millisecond The third integer is the infused volume in femtoliters All three values are for the current direction The flag field consists of six flags e Flag one is the motor direction and will be I if the pump is infusing and w if the pump is withdrawing IF the letter is lower case the pump motor is idle If upper case the pump motor is running e Flag two is the limit switch status If the infuse limit switch was hit I is displayed If the withdraw limit switch was hit W is displayed If no limit switch was hit or the pump does not have limit switches Is displayed e Flag three is the stall status and will be S if the un pump has stalled Otherwise it will be e Flag four is the trigger input state and will be T if high and if low y e Flag five is the direction port state and will be for infuse and W for withdraw e Flag six is the target reached status It will be T if the target time or volume was reached and if not 63 phone 800 323 4340 fox 847 247 2929 email infoOcoleparmer com web www coleparmer com Cole Parmer Touch Screen Series Syringe Pump User s Manual Publication 5607 009 REV B
93. phone 8 0 0 3 2 3 43 40 fax 847 247 2929 Cole Parmer Touch Screen Series Syringe Pump User s Manual email info coleparmer com web www coleparmer com Publication 5607 009 REV B Appendices 77 APPENDIX D EXTERNAL CONNECTIONS User I O Connector Specifications All Inputs are pulled high to 5 Vdc through a 10k resistor All Outputs are at TTL Logic Levels l Direction control input Rising edge sets pump to infuse Run Indicator or Voltage Falling edge sets pump to refill di 2 Trigger Input Event trigger falling edge triggers a program event 3 Footswitch Input Momentary switch closure to ground or TTL Logic Low falling edge toggles between states Evo run stop Direction In Direction Out 4 Trigger 1 Output Event In Sync Out Footswitch In Trigger 2 Out TTL Logic Output Default Low Control thru Trigger 1 Out program or serial comm 5 Trigger 2 Output User I O Connector Specifications TTL Logic Output Default Low Control thru program or serial comm 6 Sync Output TTL Logic Output Rising Edge Start Infuse Falling Edge Start Refill 7 Direction Output TTL Logic Output High Infuse Low Refill 8 Valve Output TTL Logic Output High Valve Actuated Low Valve Off Note Valve follows direction change when set to Auto 9 13 Signal Return Ground 14 Run Indicator Voltage 5V through a 470 ohm resistor connect to LED Anode 15 Run Indicator Output TTL Log
94. porting a method NOTE For additional details on the physical interfaces used to connect the Cole Parmer Touch Screen Series to external devices refer to the External I O Connections section in the Appendices Program File Options 1_PROGRAM 08 24 09 1 30 35 PM VERIFIED Program was exported to the computer Verify file exists on the PC PRESS TO CLEAR MESSAGE Export Program confirmation screen showing successful export phone 800 323 4340 fox 847 247 2929 email infoOcoleparmer com web www coleparmer com 54 TRANSFER A PROGRAM BETWEEN PUMPS Follow these instructions to transfer a Program between two Cole Parmer Touch Screen Series pumps 1 e Connect two pumps together via a RS 485 firewire type cable and set the address on the first pump to OO using the Set Pump Address command in the Settings menu Set the address on the second pump to something other than 00 using the Set Pump Address command in the Settings menu From the Program Main screen choose Program Select then choose the Program you would like to export Choose the File Options button Choose the Pump button and enter the address for the pump you would like to receive the Program Choose Export Program to Pump The pump will display a confirmation message in the Message Area on the screen when the export is complete Note that long Programs may take a few seconds to export Before disconnecting the pumps verif
95. pressing ATI and go back to the Set up screen Cancel the changes made by pressing and go back to the Set up screen NOTE The calibration date is always shown in month days year phone 800 323 4340 fox 847 247 2929 email infoOcoleparmer com web www coleparmer com 08 24 09 9 17 18 AM BACK I ENTR Press Here Pump Information 10 30 09 02 16 39 AM Model Type Programmable Software Version 0 0 7e Program Steps Available 755 807 Calibration Due Date 10 01 10 Maintenance Due 85 hours Pump Address 0 Calibration Maintenance Reset Reset BACK I ENTR Press here to Press here to reset the reset the calibration date maintenance counter NOTE Free RTOS v 0 www freertos com e Cole Parmer Touch Screen Series Syringe Pump User s Manual Publication 5607 009 REV B Operating the Cole Parmer Touch Screen Series 28 Operating the Pump The Cole Parmer Touch Screen Series is easy to operate because all the pump parameters are shown on the RUN Screen Depending on the mode of the pump different parameters will be shown on the display The Cole Parmer Touch Screen Series Run Screen is shown below Current Date and Time Run 10 29 09 02 45 16 PM Current flow rate 3 6 0 03 m MODE Infuse Only mi min SYRINGE KDS Glass 10 mi Indicates volume FORCE LEVEL 100 delivered and direction TARGET 5 ml Program settings Indicates current B rm 0 000 mi INFUSION TIME 00 00 08 flo
96. r Touch Screen 3 Choose Rename Program to access the Program Series Name Entry screen The current Program Name will be displayed in the text entry box NOTE The program management Zz procedures outlined in this section are not 4 On the Program Name screen type the new name available for basic pump modes Infuse for your Program using the onscreen keyboard Only Withdraw Infuse etc Choose the Symbols Numbers button 2123 to display the list of available numbers and symbols that can be included in the Program Name To Saving A Copy Of A Program switch the keyboard back to letters mode choose the Letters button ABC 15 characters maximum Follow these instructions to save a copy of a Program under a new name 5 When finished entering the new Program Name choose Accept to save your changes and return to 1 From Program Configuration screen choose the the File Opt l ptions screen Program Name button to enter the Mode Selection screen 6 Choose BACK to return to the Program 2 From the list of available Programs select press once the Program you want to save a copy of then choose the File Options button to enter the File Options screen 3 Choose Save As Copy to access the Program Name Entry screen The current Program Name will be displayed in the text entry box 4 On the Program Name screen type the new name for your Program using the onscreen keyboard Choose the Symbols Numbers button 2123 to display the l
97. r Touch Screen Series Syringe Pump User s Manual email infoOcoleparmer com web www coleparmer com Publication 5607 009 REV B pa Cole Parmer Delivering Solutions You Trust Configuring the Cole Parmer Touch Screen Series Setting the Audible Alarms In the Set up screen press Audible Alarms Select the alarms a check mark will indicate the alarms selected Press If these alarms are selected the pump will provide an audible alarm Accept the changes made by pressing FIT and go back to the Set up screen Cancel the changes made by pressing and go back to the Set up screen Stall Motor stalls Near End of Run When the volume dispensed is reached for the specified Mute All No audible sounds NOTE f power is removed from the pump without turning the pump switch off an audible alarm will sound To stop the audible alarm toggle the power switch to off phone 800 323 4340 fox 847 247 2929 email infoOcoleparmer com web www coleparmer com End of Run Alarm when the program is finished Audible Alarms End of Run Mute All 21 08724709 9 17 18 AM BACK I ENTR Keypad Clicks Alarm when pump When the keypad is power cycled A is touched the while running unit will provide audible feedback 08 24 09 9 18 41 AM Power Up Keypad Clicks Calibration Reminder Near End of Run BACK I ENTR Calibration Reminder Alarm when the unit has reached
98. r Bar 2400 268 Thumbscrew a 78 5100 01 Spring E 5009 164 5143 003 Flat Head Screw 2 5137 04 Anti Syphon Bar 2400 269 Thumbscrew 2 Both Sides 5100 046 Holder 2401 068 Pusher Block Assembly 1 Remove Dual Syringe Anti Syphon Bracket by unscrewing and removing the two T Knobs and two Spring Washers 2 Attach the Pusher Bar to the Pusher Block with the two flat head screws using a phillips head screwdriver A Cole Parmer phone 8 00 3 2 3 43 40 fax 847 247 2929 Cole Parmer Touch Screen Series Syringe Pump User s Manual email info coleparmer com web www coleparmer com Publication 5607 009 REV B Section Name 71 Mounting a 6 10 Multi Rack Continued Clamp Bar Knob Multi Syringe Clamp 2401 072 2401 076 10 32 x 1 2 Screw 4 5101 087 Multi Holder 2401 073 U 5 X o3 Multi Retainer 2401 075 Bracket Syringe Tl Clamp 2401 050 Lock Washer 2 5174 003 Flat Washer 2 5110 038 Dual Syringe Holder 2400 238 i Knob inde lamp 2401 051 T Knob 2 5100 059 Syringe Holder Assembly l Remove Syringe Clamp bracket from the Syringe Holder by unscrewing knob 2 Remove four set screws from the Dual Syringe holder using the provided Hex Key 3 Place the Multi Holder on the Dual Syringe Holder and attach using four 10 32 x 4 Screws using phillips head screw driver 4 Screw the two Post Clamp Guides into Multi Syringe Holder 4 Attach Clamp Bar by screwing the Mult
99. range Syringe diameter is out of range Target volume is out of range Target time is out of range Total volume exceeds syringe capacity Volume is less than the minimum value phone 800 323 4340 fox 847 247 2929 email infoOcoleparmer com web www coleparmer com ERROR 217 ERROR 218 ERROR 219 ERROR 220 ERROR 221 Program ERROR 301 ERROR 302 ERROR 305 ERROR 306 ERROR 307 ERROR 308 ERROR 309 ERROR 310 ERROR 311 ERROR 312 ERROR 313 ERROR 314 ERROR 315 ERROR 316 ERROR 317 ERROR 318 ERROR 319 ERROR 320 ERROR 321 ERROR 322 ERROR 323 ERROR 324 ERROR 325 64 Motor has stalled Use the lt lt or gt gt Key to move the pusher block Check the force setting Program needs a rate enter a rate Program needs infuse and withdraw rates and a target volume enter these parameters Date Time is out of range Incorrect Password Errors Delay time out of range minimum value is 0 20 seconds Number of steps must be between 2 and 500 Remote pump is busy or encountered an error Retry and check remote pump Download to remote pump not complete Check remote pump Syringe size and flow rate not compatible cannot set motor speed Program name already exists Rename your program Linked to program does not exist Not all fields have been set Check the configuration Rate is out of range Time is out of range Volume is out o
100. red time using the onscreen number pad Select the Time Period button to toggle between AM PM and 24 hours settings Time should be entered using hours minutes seconds hh mm ss 4 When the desired values are entered choose the Accept button to save your Changes and return to the Program Configuration screen When a Time Delay value is active the Time Delay Parameters button is displayed in Red on the screen to alert the user that a delay has been set 5 Press the Run button to activate the Delay phone 800 323 4340 fox 847 247 2929 Configuration Infuse Only KDS Glass SYRINGE me RATES 36 003 ml min Yolume TARGET ppi Program Configuration Program Name METHOD Syringe Cadence 30 ml 22 7 mm Step Definition Step 1 Constant Rate Step 2 Event Step 3 Constant Rate Set Delay Date and Time 34 10 30 09 02 02 42 AM H qa u 10 29 09 09 44 07 RM 2402 07 21 09 12 05 10 PM 21 09 Dora 120503 Ya El El 0606 MA E YA 11 EJ HP X Set Delay Date and Time screen 10 30 09 09 00 29 AM Infuse Withdraw 2 MODE 36 003 mi min NOTICE Pump will run at the F 1 0000 m FLOU DIRECTION TIME ELRPSED 00 00 00 TIME REHRINING CONTINUOUS STRTUS RERDY TO INFUSE TOTRL INF VOLUHE 0 ml following date and time 10 30 09 10 00 00 AM Press here or stop button to cancel PRESS TO CLEAR MESSAGE Quick Start run screen with a Time Delay Set Cole Parm
101. reight prepaid and correction will be made with out charge Cole Parmer Instrument Company alone will determine if the product problem is due to deviations or customer misuse Out of warranty products will be repaired on a charge basis Return of Items Authorization must be obtained from our Customer Satisfaction Department before returning items for any reason When applying for authorization please include data regarding the reason the items are to be returned For your protection item must be carefully packed to prevent damage in shipment and insured against possible dam age or loss Cole Parmer Instrument Company will not be responsible for damage resulting from careless or insufficient packing A restocking charge will be made on all unauthorized returns NOTE the Cole Parmer Instrument Company reserves the right to make improvements in design construction and appearance of our products without notice Repair Facilities and Parts Cole Parmer stocks replacement and repair parts When ordering please describe parts as completely as possible preferably using a part number obtained from our Customer Service department If practical enclose a sample part or sketch We offer a complete reconditioning service Serial Numbers All inquiries concerning our product should refer to the serial number of the unit located on the rear panel Calibrations All electrical apparatus are calibrated at rated voltage and frequency While
102. rn to Ramp Definition screen Choose the Time button to enter the Set Time screen Enter the desired Time value using the keypad 10 If the Units of Time are not correct for your e application select the Units button to toggle between sec seconds and h m s hours minutes seconds To use the h m s option enter your time value in hours minutes and seconds separating each value with a colon When all parameters are correctly set on the Set Target Time screen choose Accept to confirm your settings and return to the Ramp Definition screen Choose Accept again to return to the Step Definition screen NOTE Ramps lt 2 seconds from min to max rates may cause motor stalls Cole Parmer Touch Screen Series Syringe Pump User s Manual Publication 5607 009 REV B Operating the Cole Parmer Touch Screen Series 41 Stepped Profile The Stepped Rate profile is used to create an increasing or decreasing flow rate that varies in a series of equal steps between a starting and ending flow rate Flow Steps Rate Time Volume Stepped Rate Pump Operation Profile When creating or editing a Stepped Rate profile you will define four primary operating parameters e The Flow Mode defining the direction of flow infuse or withdraw e The Flow Rate at the beginning and end of the pumping cycle e The Target Time that determines the total length of time over which the stepped profile will be calculated
103. rogram Name To inter eons switch the keyboard back to letters mode choose the Letters button ABC phone 8 0 0 3 2 3 43 40 fax 847 247 2929 Cole Parmer Touch Screen Series Syringe Pump User s Manual email info coleparmer com web www coleparmer com Publication 5607 009 REV B pa Cole Parmer Delivering Solutions You Trus _ Operating the Cole Parmer Touch Screen Series TO CREATE A NEW USER DEFINED PROGRAM CONTINUED 4 When you have entered the desired name for your Program choose the Accept button to go to the Program Configuration screen Your new Program will now be listed in the Program Select button 5 Choose the Syringe Select button and complete the description of the syringe by following the procedure outlined previously in the Syringe Selection section of this Guide 6 To begin creating Pump Control Profile Steps choose the Step Definition button to enter the Program Steps Summary screen 7 To add a Step to your Program choose the Add Step button to access the Program Steps Menu screen The available options include Pulse Advanced Options a Constant Rate d b Ramp e Stepped Select Profile for Step 1 Constant 08 24 09 9 48 44 AM BACK Program Steps Profile Menu screen 8 Choose the Program Step type that you want to add to the Program If you choose a pumping profile e g Constant Rate Ramp etc you will be taken to the Step Definition screen for the selected
104. s 3 to 5 for the End Rate by selecting the End Rate button and continuing data entry 7 When all parameters are correctly set on the Set Start and End Rate screen choose Accept to confirm your settings and return to Stepped Definition screen 8 Choose the Time and Steps button to enter the Set Time amp Steps screen Y phone 8 0 0 3 2 3 A3 40 fax 847 247 2929 Cole Parmer Touch Screen Series Syringe Pump User s Manual email infoOcoleparmer com web www coleparmer com Publication 5607 009 REV B Operating the Cole Parmer Touch Screen Series AS Pulse Profile The Pulse Rate profile is used to create an oscillating infusion or withdrawal profile that varies between a starting flow rate and a second rate that can be either or higher or lower than the start rate The flow rate is constant within each segment of the pulsed flow profile and the user defines the total number of repetitions pulses for the oscillating pattern Each segment of the profile must be set to run for either a specific length of time or to deliver a set volume Volume Pulses Time Volume Pulse Rate Pump Operation Profile When creating or editing a Pulse Rate profile you will define four primary operating parameters e The Flow Mode defining the direction of flow infuse or withdraw e The Flow Rate to be used at each level of the pulsed profile within the pumping cycle e The length of Time that each segment of the profile will run or
105. s and return to the Constant Rate Definition screen Step Definition screen Cole Parmer Touch Screen Series Syringe Pump User s Manual Publication 5607 009 REV B Operating the Cole Parmer Touch Screen Series Ramp Profile The Ramp Rate profile is used to create a linearly increasing or decreasing flow rate for a single pumping mode infuse or withdraw over the course of a defined time period Target Time Flow Rate lt gt Time Ramp Rate Pump Operation Profile When creating or editing a Ramp Rate profile you will define three primary operating parameters e The Flow Mode defining the direction of flow infuse or withdrawl e The Flow Rate at the beginning and end of the pumping cycle e The Target Time that determines the total length of time over which the ramp will be calculated During a Ramp Rate profile the Cole Parmer Touch Screen Series varies the flow rate linearly between the starting rate and ending rate over the full time period entered A Ramp Rate profile can be applied to an increasing or decreasing rate application When creating or editing a Ramp Rate profile you can set the rate in ml ul nl or pl units of volume using sec or h m s hours minutes seconds as the units of time The system automatically calculates a minimum and maximum flow rate based on the syringe selected or custom defined The min max values are made available as button selection options on the Set Infuse a
106. s the Pusher Block in the reverse withdraw direction press amp hold Accept Used to accept the parameters settings on a screen and return to previous screen in the menu mao me y Cancel Used to cancel any changes entries on a screen and return to the previous screen in the menu DEL STEP Set Delay Parameters Used to set the date and time values for delayed operation This permits the pump to start automatically at a preset date and time MOVE Set Delay Parameters Indicates the Delay Timer has been set The pump will start automatically on the day time selected zr rri Run Preview Access the Run Preview screen that shows a summary operating parameters 23 mo T Run Resume Used to Run or Resume a Program Re Run Clears counters timers except the Total Infused Volume counter and runs the selected 24 program from the beginning Stop Used to stop running a Program Reset Resets all counters timers Minimum Value Allowed Used to select minimum value allowed Maximum Value Allowed Used to select maximum value allowed Configure Used to set up the program Back Used to call the Mode and Programs menu phone 800 323 4340 fox 847 247 2929 email infoOcoleparmer com web www coleparmer com Page Down Used to page down in a display list Page Up Used to page up in a display list Line Up Used to scroll up in a display list Line Down Used to scroll down
107. se lt lf gt Method name Size lt cr gt lt IP cr lt lf gt method name lt cr gt This line is repeated for each file on the disk lt lf gt lt If gt file s using steps lt cr gt lt f gt lt prompt gt e The last line shows the number of files and the total number of steps being used on the disk NOTE The file size is the number of steps in the method plus one for the file information header DELMETHOD Deletes a method stored in the pump Command format delmethod method DIM Sets or displays the brightness level in percent Valid range is O to 100 Note that specifying O will turn the backlight off so that the screen will not be visible Command format dim 0 100 Query response lt lf gt Backlight is set to lt cr gt lt f gt lt prompt gt Cole Parmer Touch Screen Series Syringe Pump User s Manual Publication 5607 009 REV B Operating the Cole Parmer Touch Screen Series ECHO Sets or displays the RS232 USB echo state Valid states are on or off Command format echo on off Query response If 1Ht Echo is OFF lt cr gt lt f gt lt prompt gt or IP t Echo is ON lt cr gt If 1 1 prompt FREE Displays the number of free method steps left on the disk Command format free Query response lt f gt steps used lt cr gt lt lf gt steps free lt cr gt lt f gt total steps lt
108. t free cloth to remove loose dust Use care to avoid scratching the clear display window For more efficient cleaning use a soft cloth dampened not soaked with water an aqueous solution of 75 isopropyl alcohol or a mild Cole Parmer Touch Screen Series pumps require no special maintenance other than keeping them clean by avoiding accidental spills of pumped material Refer to the chemical compatibility chart below for specific chemical resistance information det f The two guide rods and the lead screw should be SIS sparingly lubricated periodically every 100 hrs the pump will remind you The guide rods and the lead screw should be lubricated with Super Lube Synthetic Grease provided with the pump Chemical Compatibility Chart Chemical Concentration Cover A ahes ye Acetonitrile 99 5 A A Methyl alcohol 99 8 A Hydrochloric Acid 36 5 A A Bleach 100 A A Windex 100 A A Isopropyl Alcohol 99 5 A D Dish Soap A A Motor Oil 100 A A Simple Green 100 A A Gasoline 100 A D Ethylene Glycol Antifreeze 100 A A Mineral Oil 100 A A Ammonia 27 0 A A Magnalube 100 A A Superlube 100 A A Acetone 99 5 A D Soda Coca Cola 100 A A Sulfuric Acid 95 0 D D Dimethyl Sulfoxide 99 9 A C Sodium Hydroxide 50 A A Nitric Acid 68 0 D D Chloroform 100 D D The chemical resistance data provided is for reference only The data is based on the manufacturer s recommendations and is not a guarantee of chemical compatibility
109. tails for all Steps choose the Back button to return to the Program Configuration screen 10 To preview the Program choose the Preview Program button or to run the Program choose the Program Run button Cole Parmer Touch Screen Series Syringe Pump User s Manual Publication 5607 009 REV B Operating the Cole Parmer Touch Screen Series 32 Configuring Custom Programs E information screen The Cole Parmer Touch Screen Series Programmable Models offer the flexibility of configuring custom Set up 08 24 09 9 17 18 RM programs including multistep programs The programs EN and steps can also be triggered to start and stop with events and external I O and user defined inputs The ES maximum number of steps is 800 for all the programs 100 To determine if your pump is programmable go to the pump information screen The Model Type should say Programmable Press Eyal The available number of program steps is shown Pump Information 10 30 09 02 16 39 AM in the pump information screen SA Reset Reset Configuring a New Custom Program Configuration 10 30 09 02 02 42 AM To display the Mode Selection Select Mode m PIMME screen press Mode KDS Glass 10 00rnl HM C The Mode Selection screen will be displayed Mode Selection 07 21 09 11 16 10 AM Select New Program Press Y D View programs up a page aca NENNEN a A D CEE C View the programs down a page led
110. the flow and volume will stay calibrated the peak pressure may vary Cole Parmer recommends an annual calibration of the pump AIRE a aI TT Darients phone 8 00 3 2 3 43 40 fax 847 i dien Cole Parmer Touch Screen Series Syringe Pump User s Manual e mail info colepa rmer com web v N COI ler parmer com Publication 5607 009 REV B SPECIFICATIONS Accuracy Reproducibility Syringes Min Max Flow Rate Minimum 0 5 ul syringe Maximum 140 ml syringe Display Non Volatile Memory Connectors RS 232 RS 485 USB I O 8 TTL Linear Force Max Drive Motor Motor Drive Control Number of Microsteps per one rev of Lead Screw Step Rate Minimum Maximum Pusher Travel Rate Minimum Maximum Power Dimensions Weight Atmospheric Specifications Operating Temperature Storage Temperature Humidity Mode of Operation Classification Pollution Degree Installation Category Supplier Name Supplier Address Supplier Phone Number Regulatory Certifications General Information 0 35 0 05 0 5 ul 140 ml 3 12 pl min 215 803 ml min 4 3 WQVGA TFT Color Display with Touchpad Stores all settings 9 pin D Sub Connector IEEE 1394 6 pos Type B 15 pin D Sub Connector 34 kg 75 lbs 100 Force Selection 1 8 Stepper Motor Microprocessor with 1 16 microstepping 6 400 27 5 sec Ustep 26 Usec Ustep 0 36 Um min 190 80 mm min 100 240 VAC 50 60 Hz 50 W 0 5 A fuse 8 89 x 25 4 x 27
111. the specific Volume to be infused withdrawn during each segment of the profile e The Number of Pulses repetitions that will be executed during the pumping cycle During a Pulse Rate profile the Cole Parmer Touch Screen Series calculates a series of equal length pumping stages at two user defined flow rates a starting rate and a pulse rate You enter the Number of Pulses repetitions that you want to use along with how you want the system to calculate the length of each stage by time or by volume pumped A Pulse Rate profile can be applied to pulses that are higher in rate or lower in rate than the starting flow rate When creating or editing a Pulse Rate profile you can set the rate in ml ul nl or pl units of volume using sec min or hr as the units of time The system automatically calculates a minimum and maximum flow rate based on the syringe selected or custom defined The min max values are made available as button selection options on the Set Pulse Rates screens Y Cole Parmer hone 8 0 0 o 3 2 3 43 40 fax 847 247 2929 Cole Parmer Touch Screen Series Syringe Pump User s Manual Delivering Solutions You Trust P y email info coleparmer com web www coleparmer com Publication 5607 009 REV B pa Cole Parmer Operating the Cole Parmer Touch Screen Series TO SET UP EDIT A PULSE RATE PROFILE 1 From the Pulse Definition screen for a Pulse Rate profile choose the Direction button to toggle the Flow Mod
112. tion 5607 009 REV B Appendices 86 TROUBLESHOOTING 1 Infusion Accuracy Low Battery To ensure infusion accuracy always use new syringe s and measure syringe bore diameter and enter actual dimensions in millimeters mm using the Custom Syringe entry option Additionally make sure that the guide rods Infuse Only and lead screw are properly lubricated Configuration KDS Glass 2 RS 232 Difficulties 10 00rni Verify that the baud rates data framing parameters data s SETUP Ma DELAY A bits parity and stop bits on all devices are the same OS Verify flow control handshaking is set to None If an m address is set to other than address 2 make sure wc ee C e Era commands and queries are prefixed with the address Make sure straight through pinning is used for the cables do not use nullmodem cables NOTE It is recommended that you save your programs periodically by uploading them to a PC Cole Parmer Touch Screen Series Display Error Messages 3 Motor Stalled The Cole Parmer a a of a power failure This indicates that the pusher block travel has been impeded This may be caused by the syringe plunger hitting bottom a kink in the tubing occlusion syringe plunger binding or any situation requiring more force to the head of the syringe than the pump is capable of delivering To restart the pump remove the cause of stalling and or increase the force setting then press RUN The pu
113. to on power up Command format valve on off auto Query response lt f gt Infuse lt cr gt lt f gt lt prompt gt or lt f gt Refill lt cr gt Cole Parmer Touch Screen Series Syringe Pump User s Manual Publication 5607 009 REV B Operating the Cole Parmer Touch Screen Series VDUTY Sets or displays the valve duty cycle in percent Valid range is 5 to 80 Default valve is 50 If a valve actuates but does not hold in actuated position vduty command should be used to increase duty cycle percentage to allow valve to hold Command format vduty 5 80 Query response lt lf gt lt cr gt lt lf gt lt prompt gt VER Displays the short version string Command format ver Query response lt f gt Cole Parmer Touch Screen Series lt cr gt lt lf gt lt prompt gt VERSION Displays the full version string Command format version Query response lt lf gt Firmware v lt cr gt lt lf gt RTOS FreeRTOS v http www freertos org lt cr gt lt f gt Pump address lt cr gt lt f gt lt prompt gt Run commands IRUN Runs the pump in the infuse direction Quick Start mode only Command format irun RRUN Runs the pump in the opposite direction Quick Start mode only Command format rrun phone 800 323 4340 fox 847 247 2929 email infoOcoleparmer com web www coleparmer com 60 RUN Simulates a ke
114. tor must be connected to the female D sub connector on the rear of the Cole Parmer Touch Screen Series Syringe Pump using the Digital I O Adapter Order No 74905 81 Power can now be switched on with the illuminated power On Off switch on the front valve housing 3 Pump to Valve Tubing Connection Swagelok fitting should be finger tight plus 1 1 4 turn Tubing is 304 stainless steel 1 4 inch O D wall thickness 0 035 inch Appendices 87 Syringe Silicon tubing 1 4 inch OD 1 8 inch ID ME os Refill D phone 800 323 4340 fox 847 247 2929 email info coleparmer com web www coleparmer com Cole Parmer Touch Screen Series Syringe Pump User s Manual Publication 5607 009 REV B APPENDIX G ORDERING INFORMATION Appendices 88 Item No Description Item No Description Model Versions 74905 87 Upgrade Infuse Only to Infuse Withdraw 74905 50 Cole Parmer Touch Screen Infuse Only 74905 88 Upgrade Infuse Only to Programmable 74905 52 Cole Parmer Touch Screen 74905 89 Upgrade Infuse Withdraw to Programmable Infuse Withdraw Option 74905 54 Cole Parmer Touch Screen E Infuse Withdraw Programmable 74905 91 Internal Fan Optioin 74905 56 Cole Parmer Touch Screen Push Pull 74905 93 Analog Control Input Option O to 10 VDC 74905 58 Cole Parmer Touch Screen Push Pull Programmable 74905 95 Analog Control Connector docu 74905 96 Analog Co
115. umps is running and the LED turns on This will make it easy to see the pump s status The pumps are versatile and can be interconnected through the RS485 interface Cole Parmer Touch Screen Series models can be mixed and matched in the daisy chain offering maximum flexibility Up to 99 pumps can be linked together through the RS485 interface This interface is easy to use provided each pump is assigned its own unique pump address phone 800 323 4340 fox 847 247 2929 email infoOcoleparmer com web www coleparmer com For limited laboratory space the Cole Parmer Touch Screen Series can be placed on its side to reduce the footprint by 55 The display also tilts with the change to allow the user operate the pump vertically Notifications and error messages are displayed for the user to acknowledge eliminating any guesswork about problems Flow performance is optimized with a small step angle stepping motor that drives a precision lead screw and pusher block The syringe mechanism is easy to use and securely holds the syringes for smooth flow performance Advanced microstepping techniques are employed to further reduce the step angle to eliminate flow pulsation The accuracy is 0 35 and 0 05 reproducibility A wide dynamic flow range from 3 12 pl min to 215 803 ml min can be programmed into the pump Flow rates are selectable with user selected engineering units from ml ul nl pl and hours minutes and seconds Up to 34 kg 7
116. w direction FLOW DIRECTION Press to Lock Unlock Total elapsed time TIME ELAPSED 00 00 00 the touch screen Total remaining time TIME REMAINING 00 00 08 al i STATUS READY TO INFUSE C TOTAL INF VOLUME 0 ml pump operation 2 Total volume Press to go to Fast forward Press to delivered Set up screen Start Stop Fast reverse the pump Press to go to Configuration Screen Y phone 8 0 0 3 2 3 43 40 fax 847 247 2929 Cole Parmer Touch Screen Series Syringe Pump User s Manual email info coleparmer com web www coleparmer com Publication 5607 009 REV B Operating the Cole Parmer Touch Screen Series 29 O Running the Pump Run 10 30 09 02 11 41 AM z MODE Infuse Only O 35 003 ml min SYRINGE KDS Glass 10 mi Simply press the button to start the pump FORCE LEVEL 100 TARGET 5 mi D E EL omom INFUSION TIME 00 00 08 i J When the pump is running the button FLOW DIRECTION shawi TIME ELAPSED 00 00 00 wi e TIME REHRINING 00 00 08 Press the button to pause the program STATUS READY TO INFUSE e Gis E TOTAL INF VOLUME 0 mi 3 The fast forward and fast reverse key are not p active when the pump is running A The Cole Parmer Touch Screen Series can also be run in a veritical position All screens will rotate automatically when the pump is placed on its side Run 10 30 09 02 18 21 AM z MODE Infuse Only O 36 003 ml min SYRINGE KDS Glass 10 mi em FORCE LEVEL 100 TARGET 5 mi A RERE
117. web www coleparmer com Publication 5607 009 REV B pa Cole Parmer Delivering Solutions You Trust Operating the Cole Parmer Touch Screen Series PUMP CHAIN COMMANDS The Pump Chain commands allow all pump control information to be managed from an external computer source These commands can also be used to control a series of pumps up to 100 from a single computer interface Cole Parmer Touch Screen Series Series commands are communicated to the pump via the RS 232 or USB port interfaces through a terminal program such as HyperTerminal In using the Pump Chain commands you will need to assign each pump in the pump chain a unique address using the Set Pump Address command in the Settings menu The address range is from 00 to 99 This address value is used to identify which pump is to receive a command and which pump is responding The first pump in the chain the one connected to the computer must use address O zero Configure each pump with its assigned address and baud rate as described in the Pump Settings section of this guide NOTE When daisy chaining using the RJ connectors all pumps must use the same baud rate Values above 38400 are recommended NOTE Once communication is established if you manipulate the touchscreen you must reestablish communications to the PC lt CR gt will do this NOTE System commands and start stop commands can be executed from program or mode configuration screens For p
118. will need to install eries 5ottware p the Cole Parmer Touch Screen Series USB 1 Upload the latest software version to your desktop driver as well as the bootloader driver file format is filename dfu Cole Parmer Touch Screen Series Bootloader inf Reference USB Virtual 2 Connect the pump to PC using a USB cable Compact Driver Installation 3 On the setup screen press the Upgrade Software button twice to enter Boot Loader Mode The pumps screen will be blank and the light should be flashing Select Pump To Upgrade ES Pump Flash Upgrade Application Pv E To i i loader mode ad Eis Pump dfu upgrading the software power cycle the Pg g P y Verify after download _ Optimize Upgrade duration Remove some FFs 4 Disconnect then reconnect the USB cable Upgrade Verity 5 From the CD provided with the pump open the File correctly loaded Cole Parmer Touch Screen Series Flash Upgrade Application SS A MET pump 6 Check Verify after download then click browse Browse to the file previously saved on your desktop and click open 7 Click upgrade The previous software will first be erased the new software will be loaded and finally the software will be verified 8 Disconnect the USB cable and power cycle the pump Y phone 8 0 0 3 2 3 43 40 fax 847 247 2929 Cole Parmer Touch Screen Series Syringe Pump User s Manual email info coleparmer com web www coleparmer com Publica
119. y press of the run button located in the lower right corner of the screen Command format run STOP STP Stops the pump Command formats stop stp WRUN Runs the pump in the withdraw direction Quick Start mode only Command format wrun Rate commands CRATE Displays the current rate that the motor is running at A valid response is returned only in dynamic situations while the pump is running Quick Start mode only Command format crate Query response lt lf gt Infusing at xl xxx cr lt f gt lt prompt gt or lt lf gt Withdrawing at xl xxx cr lt f gt lt prompt gt DIAMETER Sets or displays the syringe diameter in mm Quick Start mode only Command format diameter syringe diameter Query response lt lf gt 31H18 mm lt cr gt lt f gt lt prompt gt Cole Parmer Touch Screen Series Syringe Pump User s Manual Publication 5607 009 REV B Operating the Cole Parmer Touch Screen Series RAMP Sets or displays the target infusion rate while ramping Quick Start mode only Command format iramp start rate start units end rate end units ramp time in seconds Query response lt f gt Ramp not set up lt cr gt lt f gt lt prompt gt or lt f gt Starting rate xl xxx cr lt lf gt Ending rate xl xxx cr lt f gt Ramp time seconds lt cr gt lt f gt lt prompt gt IRATE
120. y that the Program was successfully exported by choosing Program Select from the Program Main screen on the destination pump then browse the available Programs to verify that the exported Program is shown in the menu NOTE Before downloading or transferring a method to the pump verily the number of steps available on the pump information screen Cole Parmer Touch Screen Series Syringe Pump User s Manual Publication 5607 009 REV B Operating the Cole Parmer Touch Screen Series Exporting A Program To An External Computer Follow these instructions to export a Program to an external computer 1 Connect the pump to the external computer via a RS 232 or USB cable 2 On the computer open the HyperTerminal application and verify that the computer can communicate with the pump 3 Atthe pump from the Program Main screen choose Program Select then choose the Program you would like to export 4 Choose the FILE OPTIONS button 5 In HyperTerminal choose Transfer Capture Text 6 Enter the File Name that you want to save the Program under then choose Start 7 Choose Export Program to PC 8 The pump will display a confirmation message in the Message Area on the screen when the export is complete Note that long Programs may take a few seconds to export 9 Atthe destination computer in HyperTerminal when the Program is done transferring the message mend will appear onscreen 10 In HyperT
Download Pdf Manuals
Related Search
Related Contents
LG split hi-wall - Manual do Propietario Medidor de humedad 取扱説明書 - テスコム Onkyo PR-SC5530 Instruction Manual Frymaster FPGL330CA Spec Sheet K-BUS R KNX/DALI Gateway User manual-Ver. 1 Kompernass KH 2247 Operating Instructions manual t 37 70-79004B VoyagerBT Installation and User's Guide Rev 2.3 Copyright © All rights reserved.