1. 42205 CELL CON 305 Commerce Drive 300 Exton PA 19341 voice 610 280 7630 800 771 7139 fax 610 280 7685 web www cell con com Doc 410060 0050 04 16 08
2. charge batteries at too high or too low temperatures See tech nical specification for the batteries for allowed temperature ranges e Make sure the batteries can handle the charge current Contact battery manufacturer for details e Make sure the batteries are connected with correct polarity e Never change more battery cells than what the charger is designed for HOW TO USE THE CHARGER The Charger is started by connecting the battery pack to the charger The LED will be orange before the fast charge starts and the LED changes to red When the batteries are fully charged and the voltage drops because of the dV signal from the batteries the charger will go into a top off charge mode before it goes over to trickle charge mode During top off charge the LED will be green with short intermittent orange light When the top off charge is completed the charger will go into trickle charge mode and the LED will be green The charge current is now reduced to a safe level which allows the charger to stay connected to the NiCd batteries without damaging the batteries NiMH batteries are not as well suited for trickle charge and some battery manufacturers recommend that trickle charge does not exceed 24 hours If the safety timer disconnects before dV the top off charge will not be engaged The charger will then go directly to trickle charge mode and the LED will be green If the battery voltage is far below normal the charger will cut
3. User Manual NiMH NiCd Charger 452115 N 452215 N 452116 N 452415 N Series CELL CON READ THESE INSTRUCTIONS BEFORE USING THE CHARGER This battery charger is only designed for indoor use and should not come into contact with water or dust In order to avoid overheating 3 the charger should not be covered when it is in use If the charger is marked with a symbol with two drops of water and IP67 the unit is filled with molding material and is waterproof 66 but must not be immersed in water over long periods of time The charger is turned on by connecting it to the mains socket Disconnecting it from the mains socket turns the charger off If the charger is equipped with a mains cord verify that the cord has not been damaged If the cord is damaged the charger must not be used The mains socket should be easily accessible If an operational error occurs the plug should be immediately removed from the socket In the event that the charger is labeled EN60601 1 then it satisfies the requirements of electromedical equipment and can be used in hospital environments etc The charger must not be used in the vicinity of flammable anesthesia gases If the charger is marked with this symbol it is double insulated class Il The charger contains dangerous voltages and the cover should not be removed All service or maintenance work should be carried out by qualified personnel who can get assistance by contacti
4. e polyswitch fuse on output The unit is constructed for the lowest possible leakage current from the battery with mains disconnected lt 1mA It is still recommended that the batteries be disconnected when the mains are not connected On request the charger is supplied with battery temperature monitoring A built in temperature charge control dT dt secures optimal charge with a built in NTC resistor in the battery pack Other functions such as OdV detection and timer only charge is available upon request Most charge parameters may be altered using an external programming tool Contact manufacturer for details CHARGE CYCLE AND LED INDICATIONS D AE M PS MT With mains connected the LED will be orange the first 5 7 seconds and be orange when the initialization and analysis starts If a battery is connected the actual charging will start a few seconds later when the LED changes to red After the start timer period has run out the first few minutes of the charge cycle when the dV is undetected the LED will be green in approximately 4 seconds This is only a signaling for testing and service When dV has been detected the start of the top off charge is indicated with a green LED with intermittent orange flashes as described under the how to use the charger section The LED is green during trickle charge TEMPERATURE CONTROL OPTIONAL FEATURE If the charger is being used with temperature sensor NTC resisto
5. ng the manufacturer s agent If the product has plastic casing avoid it coming into contact with oils greases etc as most types of plastic can be broken down by chemicals and solvents Technical specification See product labeling CHARGER FUNCTIONALITY This charger is a fast charger for NiCd NiMH batteries The standard version utilizes a method called dV detection for charge termination when the batteries are fully charged This method is based on the fact that the voltage drops over the NiCd NiMH cells when batteries are fully charged This voltage drop is detected when the voltage has dropped a certain percentage from the highest value If this drop does not occur the charger has a safety timer which will terminate charging after a given time period to avoid overcharging the batteries A few cells may have a voltage drop in the first part of the charge cycle This is especially true for battery cells which have been idle for a longer period of time Because of this it is built into the charger a start timer which prevents dV detection the first minutes of the charge cycle As the charger is programmable by the factory it is possible that the standard parameters which this user manual is based on have been changed See separate user manual or contact supplier for additional information CAUTION e When charging separate battery cells avoid charging cells with different rest capacities at the same time e Do not
6. off the fast charge current and go to trickle charge mode The LED will then indicate error by flickering green and red light If the mains are turned off the charger will reset and start a new charge cycle if the mains are turned on again If new batteries are to be connected the charger must idle for approx imately 15 seconds to make sure all parameters in the microprocessor have been reset The LED changing to yellow light shows this and a new charge cycle can begin SAFETY The embedded charge program has numerous features for safe charge e The charger is made with a dV level which will adapt to the number of cells and will be equally sensitive across all cells The safety timer will protect the batteries if the dV signal fails to appear It is normal to have a safety timer that is higher than maximum charge time Some battery cells may have a voltage drop in the first part of the charge cycle Because of this a start timer that prevents dV detection during the first minutes of the charger cycle is built into the charger The charger has been programmed to disregard large voltage fluctuations due to connection of external loads Such false dV signals will be detected by the software and disregarded Top off charge after dV secures full battery capacity prior to trickle charge The charger may also be supplied without top off charge The charger is protected against reverse polarity by an automatically resettabl
7. r in the battery it is possible to add control to the battery charging process If the battery temperature is too low lt 0 C at the start of the charge cycle the charger will charge with trickle charge current until the temperature level is safe This is indicated by intermittent red flashes while the LED is green The same will take place if the battery temperature exceeds 40 C The current will then remain low until the temperature is at a level where fast charge can start If the temperature is too high gt 60 C the LED will show error by flashing red and green lights intermittently By using the temperature increase control dT dt the charger will switch to top off charge and later to trickle charge the same way as charging with dV control NOTE The charger may be programmed with other temperature parameters See separate user manual or contact supplier for additional information ZERO dV FEATURE If zero dV has been activated the charger will stop the fast charge when the voltage has not increased the last 5 minutes This feature may be the only sensor or it may be used in combination with dV and or dT dt OUTPUT CONNECTOR SPECIFICATIONS If charger is equipped with a 2 5 x 5 5 x 9 5 mm barrel plug the center position is positive If the charger is equipped with a 3 pin DIN plug please refer to illustration for proper polarity Provided DIN plug Lumber model XS32 mates with Lumberg model XK32