RU+7 User manual
Contents
1. to enter interface as Fig 3 shows Click and gt to set work time 20 minutes for body treatment 3 Click Vacuum to enter interface as Fig 4 shows 1 Click Mode to set vacuum mode Click lt and gt to regulate P1 P6 Fig 2 2 Click Intensity to set vacuum intensity Click and gt to regulate 10kPa 80kPa When it is OkPa means PETERS ss that close the vacuum function 4 Click Bipolar RF to enter interface as Fig 5 shows Click lt and gt to regulate RF output intensity 1 weak 10 strength When it is 0 means that close the RF function 5 Click PDT to open or close the Photodynamic Therapy 6 Smear the essential oils in the treatment area set work time vacuum mode vacuum intensity and bipolar RF intensity Click QD the machine start working If there is too much fat you can increase the output intensity 7 The machine will pause automatically if the setting time is over Click BJ to return to Fig 1 8 Clean the leftovers with hot towel use warm towel to clean the work head Fig 3 WORK TIME 30 00 Mode Intensity Fig 4 Face treatment WORK TIME 1 Click FACE as Fig 1 shows enter interface as Fig 6 m 2 Set work time 20 minutes for body treatment 3 Click Vacuum to set vacuum mode and intensity 1 Click Mode to set vacuum mode P1 P6 2 Click Intensity
2. RU r7 User manual Warning Dear user Thanks for using our company s products in order to fully make use of the products we sincerely suggests follow Please read the instruction in detail and keep it well for further reading and consulting 4 Please follow the instruction to fit and operate the machine correctly Please do not remove and change any accessories of the machine It forbids others to open and remove the mainframe except the authorized people in the company It forbids others to change and maintain the machine except the professional people Please contact us if there is any trouble during operation This product does not belong to medical please don t use for disease treatment Bipolar RF vacuum Bipolar RF vacuum Bipolar RF vacuum work handle for eyes work handle for face work handle for body 1 Put the accessories well and connect them to the host Insert Bipolar RF vacuum work handle for eyes face e es and body to 5 BODY FACE EYES SET While using Bipolar RF vacuum work handle for eyes face and body please insert the transparent tube to 6 2 Insert power supply line to 3 turn on the General power switch 4 Insert the IC card to 2 correctly the system will enter the interface as Fig 1 shows 3 The system automatically recognizes the work handle Fig 1 WORK TIME 30 00 1 Click BODY as Fig 1 shows enter interface as Fig 2 2 Click 3
3. it is 0 means that close the RF function 5 Click PDT to open or close the Photodynamic Therapy 6 Smear the essential oils on skin around eyes Click 1 the machine start working 7 Beautican hold the handle and operating based on the direction of the arrow in the picture and must reduce the intensity according to the less fat around eyes NOTE Do not let essential oils into eyes 8 The machine will pause automatically if the setting time is over 9 Clean the leftovers with hot towel use warm towel to clean the work head Fig 8 1 Beautician should wear insulated gloves during operation 2 Do not wear any aglet both for the beautician and the users 3 The electrode probe must be fully in contact with skin 4 Do not make the RF electrode stay on any part without moving Keep it moving on skin slowly 5 Skin around eyes and forehead is very thin the RF output intensity should be relatively weakened Click set as the Fig 1 shows Enter interface as Fig 8 Click basic setting enter the selecting language interface Notes advanced setting is for manufacturer only 1 People with heart disease or high blood pressure or configured cardiac pacemaker 2 Patients with acute inflammation asthma deep vein thrombosis thyroncus cancer 3 People with hemorrhagic disease trauma or who is bleeding 4 Pregnant women 5 Medical Plastic parts or parts with artificial in filling inside 6 People wi
4. th metal inside the body include metallic tooth 7 Patient with skin inflammation or with edema 8 People with an abnormal immune system 9 Numb or insensitive to heat Input AC110V 60Hz L AC220V 50HzL Power lt 150VA Output RF 2 6MHz 1 Host 1set 2 Power supply line 1pc 3 User manual 1 copy 4 Bipolar RF vacuum work handle for eyes 1pc 5 Bipolar RF vacuum work handle for face 1pc 6 Bipolar RF vacuum work handle for body 1pc 7 Accessory frame 1pc 8 Hexagonal screws 2pcs 9 Hexagon wrench 1pc 10 Sealing ring 15pcs
5. to set vacuum intensity 10kPa 60kPa When it is OkPa means that close the vacuum function 4 Click Bipolar RF to regulate RF output intensity 1 weak 10 strength When it is 0 means that close the mei mi RF function 5 Click PDT to open or close the Photodynamic Therapy 6 Smear the essential oils on skin around face Click 1 ue the machine start working WORK TIME 7 Beautican hold the handle and operating based on the direction of the arrow in the picture from inside to outside operating on both side right and left one side is over then to start the other side and must reduce the intensity according to the less fat on forehead if you want to pause during using please click DV NOTE Do not let essential oils into eyes 8 The machine will pause automatically if the setting time is over 9 Clean the leftovers with hot towel use warm towel to Fig 6 clean the work head Bipolar RF Fig 5 IC card times left 0 Time left 0 min WORK TIME 30 00 Eyes treatment 1 Click FACE as Fig 1 shows enter interface as Fig 7 2 Set work time 15 minutes for body treatment 3 Click Vacuum to set vacuum mode and intensity 1 Click Mode to set vacuum mode P1 P6 2 Click Intensity to set vacuum intensity 10kPa 50kPa IC card times et When it is OkPa means that close the vacuum function 4 Click Bipolar RF to regulate RF output intensity Fig 7 1 weak 10 strength When
Download Pdf Manuals
Related Search
Related Contents
T - SCHRODER, MIRIAN - UFPR Samsung RB5000J BMF cu Tehnologie Digital Inverter, capacitate 367 L Manual de utilizare Sect 7-Keyboard - Flint Machine Tools, Inc. Sony DAV-S300 User's Manual formerly Help Desk Authority 9.1.2 Le manuel de réparation & d`entretien du Poney Advisor EP TECHTIPS LT590-591 Manuale d`uso Copyright © All rights reserved.