Home

A9GT-80R1 type RGB input interface module User`s Manual

image

Contents

1. 4 Precaution for cable creating The length of the cable varies depending on the personal computer vision sensor to be used Create within the range of personal computer vision sensor specifications 3 Name of the Part s and Outline Dimension Drawing 105 4 13 i Jaser s0ri 73 2 87 43 1 69 4 35 0 17 Description Connector for connection Connector for connection to the A985GOT V Connector for mounting cable Option module mounting screw Mounting screw to the A985GOT V Rating plate are eee 4 Installation Procedure 1 Insert the AYGT 80R1 connector into the option module interface at the back of A958GOT V A985GOT V back 2 Tighten the attachment screw to a point within the prescribed torque range of 39 to 59 Necm To remove the unit reverse the installation procedure Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi machine damage or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties N For safe use e This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life e Before using
2. 005 Available as option 1DMO099 Relevant Manual For relevant manual refer to the PDF manual stored within the drawing software 1 Overview This User s Manual describes the A9GT 80R1 type RGB input interface module hereinafter A9GT 80R1 By mounting the A9GT 80R1 to A985GOT TBA V A985GOT TBD V abbreviated as A985GOT V below you can show the display of the personal computer on the A985GOT V Video input is also possible through the use of an RGB output type vision sensor When connecting to a personal computer A985GOT V A9GT 80R1 You can not show the computer s display on the computer monitor and the A985GOT V at the same time When connecting with a personal computer your computer s earth wire should be grounded When connecting to a video camera through the use of an RGB output type vision sensor RGB output type A985GOT V A9GT 80R1 vision sensor e A9GT 80R1cannot be mounted to the GOT other than A985GOT V e For details of the system configuration refer to the GOT A900 Series User s Manual GT Works Version5 GT Designer Version5 compatible Connection System Manual e For details of the RGB screen to display on A985GOT V refer to the GT Works Version5 GT Designer Version5 reference manual e One of the following software packages are required for A9GT 80R1 J version of GT Works Version5 SW5D5C GTWORKS E or higher J version of GT Designer Version5 SW5D5C GOTR PACKE or higher Af
3. M ITSUBISHI Mitsubishi Graphic Operation Terminal A9GT 80R1 type RGB input interface module Thank you for buying the MELSEC GOT Series Prior to use please read both this manual and detailed manual thoroughly and familiarize yourself with the product User s Manual Hardware MODEL A9YGT 80R1 U MODEL CODE 1DM121 IB NA 0800168 E 0406 MEE 2000 MITSUBISHI ELECTRIC CORPORATION SAFETY PRECAUTIONS Always read before starting use When using Mitsubishi equipment thoroughly read this manual and the associated manuals introduced in the manual Also pay careful attention to safety and handle the module properly These precautions apply only to the installation of Mitsubishi equipment and the wiring with the external device Refer to the user s manual of the CPU module to be used for a description of the PLC system safety precautions These e SAFETY PRECAUTIONS e classify the safety precautions into two categories DANGER and CAUTION Procedures which may lead to a dangerous condition and cause DANG ER death or serious injury if not carried out properly Procedures which may lead to a dangerous condition and cause CAUTION superficial to medium injury or physical damage only if not carried out properly Depending on circumstances procedures indicated by CAUTION may also be linked to serious results In any case it is important to follow the directions for usage Store this manual in a safe place s
4. PAN Specifications subject to change without notice Printed in Japan on recycled paper
5. ctric Asia Pte Ltd Tel 44 1707 276100 307 ALEXANDRA ROAD 05 01 02 Italy Mitsubishi Electric Europe B V Italian MITSUBISHI ELECTRIC BUILDING Branch SINGAPORE 159943 Centro Dir Colleoni Pal Perseo Ingr 2 Tel 65 6473 2308 Via Paracelso 12 20041 Agrate B Thailand F A Tech Co Ltd Milano Italy 898 28 29 30 S V City Building Office Tel 39 039 6053344 Tower 2 Floor 17 18 Rama 3 Road Spain Mitsubishi Electric Europe B V Spanish Bangkpongpang Yannawa Branch Bangkok 10120 Carretera de Rubi 76 80 Tel 66 2 682 6522 08190 Sant Cugat del Valles Indonesia P T Autoteknindo SUMBER MAKMUR Barcelona Spain Jl Muara Karang Selatan Block A Utara Tel 34 93 565 3131 No 1 Kav No 11 Kawasan Industri France Mitsubishi Electric Europe B V French Pergudangan Jakarta Utara 14440 Branch Tel 62 21 663 0833 India Messung Systems Put Ltd 25 Boulevard des Bouvets F 92741 Electronic Sadan NO 111 Unit No15 Nanterre Cedex France M I D C BHOSARI PUNE 41 1026 TEL 33 1 5568 5568 Tel 91 20 712 2807 South Africa Circuit Breaker Industries LTD Australia Mitsubishi Electric Australia Pty Ltd Tripswitch Drive Elandsfontein Gauteng 348 Victoria Road PostalBag No 2 South Africa Rydalmere N S W 2116 Australia Tel 27 11 928 2000 Tel 61 2 9684 7777 aMITSUBISHI ELECTRIC CORPORATION HEAD OFFICE 1 8 12 OFFICE TOWER Z 14F HARUMI CHUO KU 104 6212 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5 CHOME HIGASHI KU NAGOYA JA
6. ng cleaning always shut off GOT power externally in all phases Not doing so can cause a module failure or malfunction STARTUP AND MAINTENANCE PRECAUTIONS CAUTION Do not disassemble or modify any module This will cause failure malfunction injuries or fire Do not touch the conductive areas and electronic parts of this module directly Doing so can cause a module malfunction or failure Exercise care to avoid foreign matter such as chips and wire offcuts entering the module Not doing so can cause a fire failure or malfunction Always secure the cables connected to the module e g run them in conduits or clamp them Not doing so can cause module or cable damage due to dangling moved or accidentally pulled cables or can cause a malfunction due to a cable contact fault Do not hold the cable part when unplugging any cable connected to the module Doing so can cause module or cable damage or a malfunction due to a cable contact fault Before handling the unit touch a grounded metal or similar object to discharge the static electricity from the human body Failure to do so may cause the unit to fail or mulfunction DISPOSAL PRECAUTIONS Dispose of this product as industrial waste Manuals The following manuals are relevant to this product Refer to the following list and order the required manuals Detailed Manual Manual No ae A985GOT A975GOT A970GOT A960GOT User s Manual SH 4
7. o that you can take it out and read it whenever necessary Always forward it to the end user DESIGN PRECAUTIONS Do not bundle control lines or communication wires together with main circuit or power lines or lay them close to these lines As a guide separate the lines by a distance of at least 100 mm 3 94 inch otherwise malfunctions may occur due to noise INSTALLATION PRECAUTIONS Before mounting or dismounting this module to or from the GOT always shut off GOT power externally in all phases Not doing so can cause a module failure or malfunction CAUTION Use this module in the environment given in the general specifications of the GOT User s Manual Not doing so can cause an electric shock fire malfunction or product damage or deterioration When installing this unit to the GOT fit it to the connection interface of the GOT and tighten the mounting screws in the specified torque range Undertightening can cause a drop failure or malfunction Overtightening can cause a drop failure or malfunction due to GOT or screw damage WIRING PRECAUTIONS Plug the communication cable into the connector of the connected module and tighten the mounting and terminal screws in the specified torque range Undertightening can cause a short circuit or malfunction Overtightening can cause a short circuit or malfunction due to the damage of the screws or module STARTUP AND MAINTENANCE PRECAUTIONS Before starti
8. ter opening the box check that the following items are present Description A9GT 80R1 2 Specification 2 1 AIGT 80R1 specifications RGB input method pixels Analog RGB SVGA 800600 VGA 640480 Number of video input channels 1 channel Display size pixeles 800600 refresh rate 60 72 75 Hz 6840x480 refresh rate 60 72 75 85 Hz RGB external connection method D Sub15 pin 5 V DC internal current 0 25 value for individual module consumption A 5VDC Weight kg Ib 0 12 0 26 1 If VGA 640x480 dots is used since the resolution differs from that of the A985GOT V 800x600 dots blank spaces will be displayed in black 2 2 Cable Specifications The following shows the cable specifications to connect A9GT 80R1 and personal computer vision sensor connection diagram and connector 1 Cable specifications Specifications Applicable cable Equivalent to SP23 23352A UL20276 SB Applicable wire size 9 core combined cable recommended 2 Connection diagram Personal computer side Va Twisted pair 3 Connector e GOT connector Use the connector matching the following model for the GOT 15 pin D sub male inch screw type Manufactured by DDK 17HE R13150 73MC2 e Connector at the personal computer vision sensor Use the connector applicable to the personal computer vision sensor
9. the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi e This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system Country Region Sales office Tel Country Region Sales office Tel U S A Mitsubishi Electric Automation Inc Hong Kong Ryoden Automation Ltd 500 Corporate Woods Parkway Vernon 10th Floor Manulife Tower 169 Electric Hills IL 60061 Road North Point HongKong Tel 1 847 478 2100 Tel 852 2887 8870 Brazil MELCO TEC Rep Com e Assessoria China Ryoden Automation Shanghai Ltd Tecnica Ltda 3F Block5 Building Automation AV Paulista 1471 Conj 308 Instrumentation Plaza 103 Cao Bao Rd Sao Paulo City Sao Paulo State Shanghai 200233 China Brazil Tel 86 21 6475 3228 Tel 55 11 283 2423 Taiwan Setsuyo Enterprise Co Ltd Germany Mitsubishi Electric Europe B V German 6F No 105 Wu Kung 3rd RD Wu Ku Branch Hsiang Taipei Hsine Taiwan Gothaer Strasse 8 D 40880 Ratingen Tel 886 2 2299 2499 GERMANY Korea HAN NEUNG TECHNO CO LTD Tel 49 2102 486 0 1F Dong Seo Game Channel Bldg U K Mitsubishi Electric Europe B V UK 660 11 Deungchon dong Kangsec ku Branch Seoul Korea Travellers Lane Hatfield Herts AL10 Tel 82 2 3660 9552 8XB UK Singapore Mitsubishi Ele