1. If the 5827BDE was successfully returned to the normal Operating mode the yellow SEND RCV LED only on the wireless keypad will blink once Note If there will be some 5827BDEs in the SignalSentry mode and others in the normal mode in the system DIP switch 1 in the 5881EH receiver must be set to the OFF position lf this is not done only those 5827BDEs in the SignalSentry mode will be able to communicate with the receiver 5 Repeat steps 2 through 4 for each additional 5827BDE to be returned to its normal operating mode 6 Exit the Go No Go TEST mode Code OFF on the control panel Enrollment Reset All 5827BDE Keypads Returned to the Non SignalSentry Mode Note This procedure is used with any one 5827BDE to return all previously enrolled 5827BDE keypads in the system to their normal non SignalSentry operating mode This procedure also deletes all keypad serial numbers from the memory of the 5881EH receiver You will need to use this procedure if a 5827BDE in a system containing one or more 5827BDEs has been lost or stolen or if you suspect that the keypad encryption has been compromised in some way When the following procedure has been performed with one 5827BDE all existing 5827BDEs including any new replacements can then if desired be re enrolled as SignalSentry devices following the procedure in the previous section entitled Enrollment Procedure 1 Place the control panel in the Go No Go TEST mode
2. c Alarm memory history if present see Alarm Memory on next page should be cleared only at a wired keypad so that the zone s displayed there that were in alarm condition can first be determined Quick Key Operation Note Quick Key operation should NOT be used if a relay command utilizing the key has been programmed in the system ex 1234 7 When programmed for Quick Key operation the 5827B 5827BDE permits the use of the key instead of the usual 4 digit security code for all functions or for all functions except disarm as selected earlier First press the ON STAT key Next press the key and select the desired function as follows Quick Key Arm This is similar to the QUICK ARM function via wired keypads but once programmed here it is always functional whether the system is programmed for QUICK ARM or not To Arm AWAY enter AWAY To Arm STAY enter STAY To Arm INSTANT enter INSTANT To Arm MAXIMUM enter MAXIMUM Quick Key Disarm This is a unique function Wired keypads do not allow quick disarming To DISARM enter OFF Quick Key Chime To toggle CHIME mode on or off enter CHIME Panic Keys The A B and C keys on the wireless keypad are comparable to the individual keys or key pairs i e 1 amp amp and 3 amp respectively present on other keypads and their function will correspond to the control
3. 2 through 4 for each additional 5827BDE up to eight to be enrolled as a SignalSentry device 6 Exit the Go No Go TEST mode on the control panel Code OFF Returning a 5827BDE To Its Normal Operating Mode Non SignalSentry This procedure is included for those cases where you may wish to convert a 5827BDE previously enrolled as a SignalSentry device to normal operation Important In cases where there is only one 5827BDE in the system and you wish to return it to its normal operating mode or where there are multiple 5827BDEs in the system and you wish to return all 5827BDEs to their normal mode use the procedure entitled Enrollment Reset 1 Place the control panel in the Go No Go TEST mode this will reduce the receiver sensitivity 2 Power up the 5827BDE keypad press key and place the unit in the keypad programming mode by depressing the 1 and 3 keys at the same time for 3 seconds Alternate blinking of the Red and Green LEDs confirms that the 5827BDE is in the keypad programming mode 3 Enter the following key sequence on the 5827BDE 7 4 digit master code The 5827BDE will beep 3 times and the 3 LEDs will begin blinking once every 2 seconds Allow them to blink several times before exiting the keypad programming mode lf a single long beep is heard the device was either not enrolled as a SignalSentry device or it is not a 5827BDE 4 Exit the keypad programming mode by keying
4. of control used and its programming Refer to the control s installation manual 4 Connect the provided antenna if necessary by screwing it into its threaded connector at the top of the wireless keypad The keypad has an internal antenna and in many installations the system will operate adequately with this antenna alone However for large installations where longer range may be required it may be necessary to add the external antenna 5800TM Transmitter Module Installation Installation instructions accompany the 5800TM but are given here as well for your convenience Observe the same precautions in selecting a location for the 5800TM as for the system s RF receiver to ensure good transmission and reception The 5800TM must be located next to the system s receiver between one and two feet from the receiver s antennas Do not install the 5800TM within the system control panel s cabinet Mount it remotely on its accompanying mounting bracket The bracket is identical to the one that accompanies the wireless keypad and may be mounted in the same way 5800TM Transmitter Module Programming For an Addressable System 1 Select one of the following addresses for the 5800TM by removing its cover and cutting the appropriate jumper s on its circuit board as follows FOR ADDRESS CUT JUMPER S RED Wi WHITE Wa Co w BOTH 2 Program the control panel by designating the address selected above as a wired keypad in the syste
5. s program ming for them All three panic keys may not be active for the system with which the keypad is used This depends on the capabilities of the control used and its programming No prior depression of the ON STAT key is needed Depression of any of the 3 panic keys for two seconds causes the transmission of its function if as programmed by the control and powers up the keypad as well The yellow transmission reception LED will light a brief key actuation blip will occur and the display of the system status will be initiated but for personal safety purposes confirmation sounds will not be emitted Alarm Memory If the ON STAT key is pressed during or following a fire or burglary alarm sounding period the wireless keypad will annunciate the appropriate warning sounds Successive depression of the ON STAT key will toggle these sounds off and on to alternate with the annunciation of the system s armed or disarmed status The system can be disarmed by entering the appropriate disarm sequence at the 5827BD or 5827BDE or any keypad Alarm memory history will still be present however as evidenced by the wireless keypad s blinking red LED and silent sounder Normally alarm memory history is cleared by entering the system s disarm sequence a second time after the system is disarmed In this case this second disarm sequence should be performed at a wired keypad after the zone s displayed there that were in alarm con
6. this will reduce the receiver sensitivity 2 Press key to power up a 5827BDE keypad and place that unit in the keypad programming mode by depressing the 1 and 8 keys at the same time for 3 seconds Alternate blinking of the Red and Green LEDs confirms that the unit is in the keypad programming mode 3 Immediately enter the following key sequence on the 5827BDE to return all 5827BDEs to their normal non SignalSentry mode and delete their serial numbers from the 5881EH 3 4 digit security code You must enter the code in reverse for this sequence example if code is 1 2 3 4 enter 4 3 2 1 The 5827BDE will beep 3 times and the 3 LEDs will begin blinking once every 2 seconds Allow them to blink several times before exiting the keypad programming mode If asingle long beep is heard the 5827BDE was either not in theSignalSentry mode is not a 5827BDE or the key sequence in step 3 was not the first function performed after entering the keypad programming mode 4 Exit the keypad programming mode by keying lf all 5827BDEs in the system have been successfully returned to their normal mode the yellow SEND RCV LED only on the wireless keypad will blink once If not the 5827BDEs were not returned to their normal mode and you will need to repeat steps 2 through 4 Note that when all 5827BDEs are returned to the normal non SignalSentry mode the 5881EH receiver will once again be able to co
7. For use with Q E D control panels only ADEMCO _ Previous menu N6484V3 3 96 5827BD and 5827BDE WIRELESS BI DIRECTIONAL KEYPADS Used with 5800TM Transmitter Module INSTALLATION INSTRUCTIONS and OPERATING GUIDE Unless otherwise indicated all information in this manual is applicable to both the 5827BD and 5827BDE GENERAL INFORMATION The 5827BD and 5827BDE Wireless Bi directional Keypads are designed to be used in conjunction with a 5800TM Transmitter Module Additional 5827BDs any quantity may be used in conjunction with the same 5800TM however no more than eight 5827BDEs may be used The 5800TM is compatible with any control panel that is a so equipped with a 4281 type 5700 System or 5881 type 5800 System RF receiver Note The 5827BDE is an enhanced version of the 5827BD and employs Ademco s new SignalSentry technology which can provide high security wireless transmissions when used in conjunction with the 5881EH RF receiver The 5827BD and 5827BDE can operate the protection system similarly to other wireless keypads via keypad buttons In addition three LEDs Red Green and Yellow and a piezoelectric sounder can indicate status information relative to System arming trouble emergency RF transmission confirmation and 5827BD 5827BDE programming and power The keypad configuration is similar to that of standard keypads The x key however is also the ON STAT power up and system status inqu
8. R A PARTICULAR PURPOSE OR OTHERWISE WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF IN NO CASE SHALL SELLER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMPLIED OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER S OWN NEGLIGENCE OR FAULT Seller does not represent that the products it sells may not be compromised or circumvented that the products will prevent any personal injury or property loss by burglary robbery fire or otherwise or that the products will in all cases provide adequate warning or protection Customer understands that a properly installed and maintained alarm may only reduce the risk of a burglary robbery fire or other events occurring without providing an alarm but it is not insurance or a guarantee that such will not occur or that there will be no personal injury or property loss as a result CONSEQUENTLY SELLER SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY PROPERTY DAMAGE OR OTHER LOSS BASED ON A CLAIM THE PRODUCT FAILED TO GIVE WARNING HOWEVER IF SELLER IS HELD LIABLE WHETHER DIRECTLY OR INDIRECTLY FOR ANY LOSS OR DAMAGE ARISING UNDER THIS LIMITED WARRANTY OR OTHERWISE REGARDLESS OF CAUSE OR ORIGIN SELLER S MAXIMUM LIABILITY SHALL NOT IN ANY CASE EXCEED THE PURCHASE PRICE OF THE PRODUCT WHICH SHALL BE THE COMPLETE AND EXCLUSIVE REMEDY AGAINST SELLER This warranty replaces any previous warr
9. ample operating the keypad on or near large metal objects may decrease range and or block transmissions 1 Install the keypad s 9 volt Alkaline battery Slide off the battery compartment cover at the rear of the keypad and insert the battery Observe polarity Then replace the cover 2 Program the keypad s memory as indicated next ANTENNA OPTIONAL j SOUNDER LEDS GREEN YELLOW RED C 3 B x A 1 PANIC KEYS AFFIX PANIC KEY LABELS HERE POWER UP KEY ADEMCO Programming the Wireless Keypad a Power up the keypad by depressing the key The yellow LED will blink If the keypad was previously programmed the system status may also be annunciated see Power up and System Status Inquiry on the next page b Enter the keypad programming mode by depressing both the 1 and 3 keys at the same time for 3 seconds Alternate blinking of the red and green LEDs confirms that the unit is in the keypad programming mode c Program the desired functions in the order given in the Programming table that follows Note that every sequence starts with a and ends with a PROGRAMMING TABLE FOR 5827BD AND 5827BDE Note A section later in this manual provides the necessary information for enrolling the 5827BDE as a SignalSentry high security device See Enrolling the 5827BDE as a SignalSentry Device However the 5827BDE must first be set up and tested in its normal operating mode as indicate
10. anties and is the only warranty made by Seller on this product No increase or alteration written or verbal of the obliga tions of this Limited Warranty is authorized ADEMCO ALARM DEVICE MANUFACTURING COMPANY A Division of Pittway Corporation 165 Eileen Way Syosset New York 11791 Copyright 1993 PITTWAY CORPORATION N6484V3 3 96
11. d PULSED BEEPING ARMED FIRE ALARM IN ae ae OAN ES ANN OR MEMORY OF IT IS PRESENT ARM BLINKING GREEN READY YELLOW SEND RCV RED amp ALTERNATELY SILENT 5827BD 5827BDE IS IN KEYPAD PROGRAMMING GREEN BLINKING MODE With 4111XM and VISTA 20 systems status monitoring is restricted to Partition 1 however each partition can be controlled by 5827BD 5827BDEs programmed to the partition s House ID Upon the depression of the ON STAT key or following an arm or disarm sequence Successive depression of the ON STAT key will toggle these sounds off and on to alternate with the annunciation of the system s armed or disarmed status See Alarm Memory No yellow light blinking may indicate a low battery also displayed on wired keypads as 00 or 64 Routine Operation The routine operation of the 5827BD or 5827BDE arm disarm chime is similar to the operation of other wired keypads used with the system as described in the system s User s Manual Press the ON STAT key before performing the desired operation Note The following considerations are necessitated by the fact that there is no zone display on the 5827BD or 5827BDE a If the system is not ready to arm green LED blinking a wired keypad s display can determine which zone is not ready b Bypassing protection zones should only be performed at a wired keypad so that it can be determined which zones are to be bypassed
12. d in the following sections FUNCTION ENTER 1 To Enter YOUR System s 4 Digit Master Code 8 4 Digit Master Code 2 To Enable Quick Key Operation Arm Disarm amp Chime or To Enable Quick Key Operation Arm amp Chime but not Disarm 3 To Enter YOUR 5700 5800 System s House ID e g 06 selected from 01 31 4 To Enter RF System Used 5700 system 4281 type RF receiver Or To Enter RF System Used 5800 system 5881 type RF receiver 1 4 Digit Master Code 2 4 Digit Master Code x 9 0 6 5 7 fl 5 8 PA 5 To Exit the keypad programming mode t Enabling Quick Key may be skipped if this is not desired Notes 1 a Following a valid entry a triple beep 2 The keypad can be re programmed at any time Upon the detection of each closing a confirmation sound is generated b Following an erroneous entry a single long 2 sec beep 3 Each time the keypad programming mode is entered Quick Key operation is disabled and must be re enabled if so desired 3 Affix the appropriate panic key label to the space below any panic key that is active according to the function that has been programmed for it in the control A sheet of labels accompanies the wireless keypad Note Not all of the three panic keys may be active for the system with which the keypad is used This depends on the type
13. dition have been determined Enrolling a 5827BDE as a SignalSentry Device When enrolled as a SignalSentry device the 5827BDE can provide high security wireless transmissions when used in conjunction with the 5881EH RF receiver This is made possible through the use of the SignalSentry technology in the 5827BDE and 5881EH When the 5881EH RF receiver is placed in its high security mode DIP switch 1 ON the receiver will accept normal wireless commands until a 5827BDE is enrolled as SignalSentry device Thereafter the RF receiver will ignore commands INCLUDING PANIC KEYS from a 5827 5827BD or any 5827BDE operating in the normal mode Important The control panel a wired keypad the 5800TM and all 5881EHs used must be installed and operating before a 5827BDE can be enrolled as a SignalSentry device Also set up the 5827BDE and perform any programming required as indicated on the previous pages for both a 5827BD and 5827BDE 5881EH RF receivers must be set to the high security mode DIP switch 1 ON if all 5827BDEs in the system will be operating in the SignalSentry mode If other wireless keypads 5827s 5827BDs are also in the system set DIP switch 1 in the RF receiver to the OFF position This will enable all wireless keypads to function in the system whether in the SignalSentry or normal mode Enrollment Procedure 1 Place the control panel in the Go No Go TEST mode this will reduce the receiver sensitivity Ref
14. er to the control panel s instructions for the entry required 2 Power up the 5827BDE keypad press key and place the unit in the keypad programming mode by depressing the 1 and 8 keys at the same time for 3 seconds Alternate blinking of the Red and Green LEDs confirms that the unit is in the keypad programming mode 3 Enter the following key sequence on the 5827BDE 6 4 digit master code The 5827BDE will beep 3 times and the 3 LEDs will begin blinking once every 2 seconds Allow them to blink several times before exiting the keypad programming mode If a single long beep is heard the device is not a 5827BDE Note If using a 2 receiver system walk through the entire area where the keypad will be used as the keypad must be enrolled by both receivers the 3 LEDs will continue to blink once every 2 seconds If you are not sure whether you have one or two receivers walk through the entire area anyway 4 Exit the keypad programming mode by keying Shortly after exiting the programming mode all 3 LEDs on the wireless keypad will blink briefly If the keypad has been successfully enrolled the system status will be displayed by one of the LEDs on the 5827BDE after a few seconds armed or ready At this time some systems will emit 3 beeps from the wired keypad s If unsuccessful the system status will not be displayed by the 5827BDE and you must repeat steps 3 and 4 5 Repeat steps
15. hnology in the 5827BDE and 5881EH REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL PANEL WITH WHICH THIS DEVICE IS USED FOR DETAILS ON LIMITATIONS OF THE ENTIRE ALARM SYSTEM ADEMCO LIMITED WARRANTY Alarm Device Manufacturing Company a Division of Pittway Corporation and its divisions subsidiaries and affiliates Seller 165 Eileen Way Syosset New York 11791 warrants its products to be in conformance with its own plans and specifications and to be free from defects in materials and workmanship under normal use and service for 18 months from the date stamp control on the product or for products not having an Ademco date stamp for 12 months from date of original purchase unless the installation instructions or catalog sets forth a shorter period in which case the shorter period shall apply Seller s obligation shall be limited to repairing or replacing at its option free of charge for materials or labor any product which is proved not in compliance with Seller s specifications or proves defective in materials or workmanship under normal use and service Seller shall have no obligation under this Limited Warranty or otherwise if the product is altered or improperly repaired or serviced by anyone other than Ademco factory service For warranty service return product transportation prepaid to Ademco Factory Service 165 Eileen Way Syosset New York 11791 THERE ARE NO WARRANTIES EXPRESS OR IMPLIED OF MERCHANTABILITY OR FITNESS FO
16. iry key instead of a READY key as it is on other keypads see OPERATION There are three panic keys A B and C comparable to the individual keys or panic key pairs of 1 amp amp and 3 amp respectively on other keypads The 5827BD and 5827BDE keypads if so programmed also feature Quick Key operation which allows use of the key instead of entry of the security code when performing functions 5800TM Transmitter Module For every installation of one or more 5827BD or 5827BDE Wireless Keypads one 5800TM is required The 5800TM complements the RF receiver in that it transmits the information to be displayed on or sounded by the 5827BD or 5827BDE No modification to the control is necessary The 5800TM connects directly to the control s wired keypad connection points as described later 5827BD amp 5827BDE INSTALLATION The 5827BD and 5827BDE are designed to be portable for use throughout the protected premises If desired a wireless keypad may be stored on its accompanying mounting bracket easily installable via two countersunk mounting holes Keyhole slots on the rear of the keypad slip onto two hooks on the mounting bracket allowing the keypad to be easily removed when desired When operating or selecting a location for storing the wireless keypad observe the same precautions as used for locating the wireless system s other transmitters see the control panel s instruction manual For ex
17. m s Device Programming section 3 For addressable 2 partitioned systems i e Vista 40 cut Red for partition 1 or White for partition 2 No additional program ming is necessary For a Non Addressable System Do not cut any jumpers No programming is required 5800TM Transmitter Module Wiring Connections Connect the 5800TM to the control panel s keypad connection points using the supplied connector with flying leads Wire colors and functions match those for wired keypads RED 12VDC BLACK Ground GREEN Data to Control Panel YELLOW Data from Control Panel BLUE Not used OPERATION Power up and System Status Inquiry Touching the ON STAT key powers up the wireless keypad and sends an inquiry to the 5800TM requesting the system status to be annunciated see table on next page Subsequent depressions of the same key will initiate additional inquiries Notes 1 Upon power up by depression of the ON STAT key the yellow LED will blink The yellow LED will be lit during RF communication indicating transmission is in progress or reception has just been completed f a low battery condition exists in the wireless keypad it will be displayed on wired keypads as zone 00 or 64 on some controls 2 At any time following a power up the depression of any key and its acceptance by the keypad will be indicated by a blink of the yellow LED and a brief key actuation blip will be heard As ex
18. mmunicate with all wireless devices even if the 5881EH receiver is set to the high security mode 5 Exit the Go NoGo TEST mode Code OFF on the control panel SignalSentry Operation Summary of Procedures Enrolling a 5827BDE in the SignalSentry Mode Retuming a 5827BDE to Normal Non SignalSentry Operation Returning All 5827BDEs in the System To Their Normal Non SignalSentry Mode Enrolling a 5827BDE as a SignalSentry Device 1 Set 5881EH receiver to the high security mode if all 5827BDE keypads in the system are to be enrolled in the SignalSentry mode by setting DIP switch 1 in the receiver to the ON position Place control panel in Go NoGo Test mode Power up the 5827BDE Place 5827BDE in Keypad Programming mode Key 6 4 digit master code The 5827BDE will beep 3 times and the 3 LEDs will begin blinking once every 2 seconds Walk through entire area where the 5827BDE is to be used 7 Exit the Keypad Programming mode on the 5827BDE 8 Observe that all 3 LEDs blink briefly If the 5827BDE was successfully enrolled the system status will also be displayed on the 5827BDE after a few seconds ARM or READY LED will light In some systems the wired keypad will also emit 3 beeps If enrollment was unsuccessful system status will not be displayed on 5827BDE 9 Repeat steps 3 through 8 for all other 5827BDEs 10 Exit the Go No Go Test mode on control panel a fF WO Nh D Ret
19. n blinking once every 2 seconds Allow them to blink several times before going to the next step 5 Exit the Keypad Programming mode on the 5827BDE 6 If all 5827BDEs in the system were successfully returned to their normal operating mode and deleted from the 5881EH the yellow SEND REC LED only on the 5827BDE will blink once 7 Exit the Go No Go Test mode on the control panel Note that if all 5827BDEs are in their normal non SignalSentry mode the 5881EH receiver will once again be able to communicate with all wireless keypads even if the 5881EH receiver is set to the high security mode If you wish to re enroll one or more 5827BDEs as a SignalSentry device follow the procedure under Enrolling a 5827BDE as a SignalSentry Device 5827BD 5827BDE SPECIFICATIONS Physical 2 3 8 W x 6 1 4 H x 1 1 4 D 61mm x 159mm x 32mm Battery 9 volt Alkaline Ademco 464 Duracell MN1604 or Eveready 522 If a low battery condition exists it will be displayed on wired keypads as zone 00 LEDs Red Green and Yellow for system status indications Sounder Piezoelectric 4200 Hz for confirmation trouble and emergency beeps and sounding on alarm In addition upon lack of response from the control a long 2 second beep is heard 5827BDE Only Can provide high security encrypted wireless transmissions when used in conjunction with the 5881EH RF receiver This is made possible through the use of Ademco s new SignalSentry tec
20. plained later a panic key has to be continuously depressed for at least 2 seconds in order to power up and or be accepted by the system 3 A long 2 second beep occurring within 4 seconds after power up or following the last key depression of a command or an inquiry indicates lack of response from the control via the 5800TM Press the ON STAT key again or move to a new location and re key your commana Approximately 10 seconds after the last key depression the wireless keypad will automatically power down No subsequent LED or sound indications will occur until the unit is again powered up thus in chime mode the chime is not annunciated by the wireless keypad The following table shows the various status indications that can occur during the time that the unit is powered up SYSTEM STATUS INDICATIONS for 5827BD 5827BDE LED cheer KEYPAD S SOUNDER SYSTEM STATUS 2 BEEPS 2 ARMED AWAY OR MAXIMUM oe 3BEEPS ARMED STAY OR INSTANT STEADY SOUND ARMED BURGLARY IN PROGRESS OR MEMORY OF IT IS PRESENT SILENT DISARMED BUT NOT YET CLEARED OF ALARM MEMORY HISTORY BURGLARY OR FIRE ONSTEADILY STEADILY 1 1BEEP 1BEEP DISARMED READY TO ARM Eo SILENT DISARMED NOT READY TO ARM BLINK BRIEF BLIP KEY DEPRESSION AFTER POWER UP BLINK SILENT UPON 5827BD 5827BDE POWER UP RF TRANSMISSION IN PROGRESS OR RECEPTION JUST COMPLETED and as explained in the INSTALLATION section for the wireless keypa
21. urning a 5827BDE To Its Normal Operating Mode Non SignalSentry 1 Place control panel in Go NoGo Test mode 2 Power up the 5827BDE 3 Place 5827BDE in Keypad Programming mode 4 Key 7 4 digit master code The 5827BDE will beep 3 times and the 3 LEDs will begin blinking once every 2 seconds Allow them to blink several times before going to the next step 5 Exit the Keypad Programming mode on the 5827BDE If the 5827BDE was successfully returned to the normal non SignalSentry mode the yellow SEND REC LED only on the 5827BDE will blink once 6 Repeat steps 2 through 5 for each 5827BDE to be returned to normal operation Note If there is more than one 5827BDE in the system and all are to be returned to their normal mode follow the procedure in Enrollment Reset starting at step 2 Otherwise proceed to step 7 7 Exit the Go NoGo Test mode on the control panel Note that if the 5881EH is in the high security mode and at least one 5827BDE is in the SignalSentry mode any 5827BDEs in the normal mode and any other wireless keypads will be unable to communicate with the system Enrollment Reset All 58327BDE Keypads Returned To Normal Operation 1 Place control panel in Go No Go Test mode 2 Power up a 5827BDE 3 Place that 5827BDE in Keypad Programming mode 4 Immediately key 3 4 digit master code Enter code in reverse The 5827BDE will beep 3 times and the 3 LEDs will begi