Ziton ZP2 Fire Alarm Panel
Contents
1. Customers who wish to obtain maximum standby time from batteries 24 to 72 hours may see this fault indication A low battery indication means that the batteries are discharged and does not indicate that they are defective ZP2 F Series Fire Alarm Control Panel Operation Manual 13 Control panel operation User levels Access to some of the features of this product is restricted by the user level assigned to a user account Public The public level is the default user level This level allows basic operational tasks such as responding to a fire alarm or fault warning at the control panel No password is required See Public level operation on page 16 for more information Operator The operator level allows additional operational tasks and is reserved for authorized users who have been trained to operate the control panel The default password for the default operator user is 2222 See Operator level operation on page 18 for more information Restricted user levels Restricted user levels are protected by password security You are required to enter the username and password assigned to you by your maintenance or installation contractor The control panel automatically exits from a restricted user level and reverts to the public user level after two minutes if no button is pressed To enter a restricted user level 1 Press F4 Main menu The username and password prompt appears on the LCD 2 Select y
2. General system events User sessions Actions Rules activation Conditions deactivation Power supply faults eliminated The control panel is reset the panel is silenced a new date and time is set the system is initiated etc The date and time information for activation and termination of user sessions An output group is activated or deactivated or a programmable system command is executed via the Configuration Utility A rule is activated 1 A system condition is deactivated A previously logged power supply fault is resolved 1 A rule consists of one or more states combined by Boolean operators that are configured to trigger specific system actions after a specific confirmation time Rules are created by your installation or maintenance contractor using the configuration utility Summary of status indications This section includes a summary of the control panel status indications Standby Standby is indicated as follows The Supply LED is steady e If a sounder delay has been enabled the Sounder Delay LED is steady e Ifa fire routing delay has been enabled the Fire Routing Delay LED is steady e Ifa fire protection delay has been enabled the Fire Protection Delay LED is steady ZP2 F Series Fire Alarm Control Panel Operation Manual Note Depending on your fire system configuration the buzzer may sound intermittently to indicate an enabled delay condition Fire alarm In accordance with Europea
3. A flashing LED indicates a battery fault A steady LED indicates a mains or mains fuse fault Indicates an earth isolation fault Indicates that the control panel is running on battery power and that the remaining charge may be insufficient to guarantee continued operation Indicates a control panel system failure The LED indicates what happens when the button is pressed If the LED is on flashing or steady pressing the button silences the sounders If the LED is off pressing the button activates the sounders if the control panel status and operating mode allow manual activation of sounders The LED also indicates the status of the sounders Steady indicates that sounders are active or will be activated shortly e Flashing indicates that a delay is counting sounders are activated when the configured delay elapses or when the delay is cancelled Off indicates that the sounders are off or will be deactivated shortly Control LED LED colour Description Notes To prevent the immediate silencing of sounders when an alarm is first reported the Sounder Start Stop button may be temporarily blocked when a configured sounder delay is counting down For more information see Stopping sounders or restarting stopped sounders on page 19 Depending on the size of the installation processing commands to start or stop sounders may take a few seconds to travel through the system This is why for example
4. ZP2 F Series Fire Alarm Control Panel Operation Manual 1 Repeater functionality All control panels in a fire network can be configured for repeater functionality This includes fire alarm control panels provided that they have a network board installed For more information on this feature contact your installation or maintenance contractor Fire routing and fire protection control and indication In this document information on control and indication for fire routing and fire protection applies only to control panels that include those features ZP2 F Series Fire Alarm Control Panel Operation Manual Control panel overview This topic provides an introduction to the control panel user interface LCD operator controls and indicators The user interface Figure 1 The control panel user interface with fire routing and fire protection controls 9 o 4 5 WN gt 60 22 10 11 10 1843 B 4 00 00 cof 21 J FIRE DETE TIONINGTALLATION PO T OLE 21 0 F2 pe J Fa O C P La p 6 2 E DA A LT O O 6 Supply LED 13 System Fault LED General Test LED General Disable LED
5. the LED may be steady but sounders may not initially be audible Panel Silence button Yellow Silences the buzzer aug LER A steady LED indicates that the buzzer has been silenced Reset button and LED Yellow Resets the control panel and clears all current system events A steady LED indicates that the control panel can be reset in the current access level Sounder fire routing and fire protection indications The control panel may be configured by your installer to have several sounder fire routing or fire protection groups As groups of a single type may not always share the same status the front panel indications for the corresponding group type display the general status for all groups In the case of conflicting status the highest priority status is displayed The following examples illustrate this operation There are three sounder groups the first in fault status the second in delayed status and the third in activated status The sounder LED indications display the fault status of the first group the delay status of the second group and the activated status of the third group There are two fire routing groups the first is in activated status and the second is in acknowledged status The fire routing indication displays the acknowledged status but not the activation status the acknowledgement status takes priority For more information on your control panel configuration and indications contact your installa
6. 0 or later This document must not be used as a guide to operation of control panels with an earlier firmware version To check the firmware version of your control panel see the Revision report in the Reports menu For more information see Viewing reports on page 20 Fire alarm and repeater panels The series includes the control panels shown below Table 1 Fire alarm and repeater panels Model Cabinet size Description ZP2 F1 Large One loop addressable fire alarm control panel ZP2 F1 S Small ZP2 F1 FB Large One loop addressable fire alarm control panel with fire 2P2 F1 FB S Small routing and fire protection controls ZP2 F1 SC Large One loop addressable fire alarm control panel with fire 2P2 F1 SC S Small routing and fire protection controls 1 ZP2 F2 Large Two loop addressable fire alarm control panel ZP2 F2 S Small ZP2 F2 FB Large Two loop addressable fire alarm control panel with fire ZP2 F2 FB S Small routing and fire protection controls ZP2 F2 SC Large Two loop addressable fire alarm control panel with fire 7P2 F2 SC S Small routing and fire protection controls 1 ZP2 FR Large Addressable fire alarm repeater panel ZP2 FR S Small ZP2 FR FB Large Addressable fire alarm repeater panel with fire routing and ZP2 FR FB S Small fire protection controls ZP2 FR SC Large Addressable fire alarm repeater panel with fire routing and ZP2 FR SC S Small fire protection controls 1 1 Includes a fireman s key
7. as unsorted municipal waste in the European Union See the product documentation for specific battery information The battery is marked with this symbol which may include lettering to indicate cadmium Cd lead Pb or mercury Hg For proper recycling return the battery to your supplier or to a designated collection point For more information see www recyclethis info For contact information see www utcfireandsecurity com Content Introduction 1 Firmware compatibility 1 Fire alarm and repeater panels 1 Repeater functionality 2 Fire routing and fire protection control and indication 2 Control panel overview 3 The user interface 3 Front panel controls and indicators 4 LCD controls and indicators 7 Indication of remote and local events on the LCD 9 Acoustic indicators 9 Summary of conditions 9 Summary of status indications 10 Control panel operation 14 User levels 14 Operation controls and procedures 15 Public level operation 16 Operator level operation 18 Maintenance 22 Menu maps 24 Regulatory information 25 ZP2 F Series Fire Alarm Control Panel Operation Manual ZP2 F Series Fire Alarm Control Panel Operation Manual Introduction This is the operation manual for the ZP2 F Series Fire Alarm Control Panels Read these instructions and all related documentation entirely before operating this product Firmware compatibility Information in this document covers control panels with firmware version 2
8. 4 Enter and then press F1 Back Press F1 Save F3 Apply F4 Discard or F2 Exit Remember to apply saved settings from the Main menu gt er 20 ZP2 F Series Fire Alarm Control Panel Operation Manual Figure 5 Changing the operator password Password setup 0000 00 User Operator Current Dee Mew Confirm EEEE far Backs k i 014 a Enter Performing an LED and buzzer test Perform and LED and buzzer test to confirm that the LED indicators and control panel buzzer are working correctly To perform an LED and buzzer test 1 Select Tests from the Main menu 2 Select Ul tests and then Indicators test During the test the control panel buzzer sounds and all LED indicators are steady The test continues for two minutes Press F2 Exit to exit the test before the default timeout Performing a keyboard test Perform a keyboard test to confirm that the buttons are working correctly To perform a keyboard test 1 Select Tests from the Main menu 2 Select Ul tests and then Keyboard test 3 Press a button on the control panel interface A message appears on the LCD to confirm that the button has been pressed 4 Repeat step 3 for all buttons 5 Press F2 Exit Performing an LCD test Perform an LCD test to confirm that the LCD is working correctly To perform an LCD test 1 Select Tests from the Main menu 2 Select Ul tests and then LCD test A test pattern displays on the LCD to help iden
9. General Fault LED Alarm LED LCD Sounder Delay button and LED 14 Low Battery LED 15 Earth Fault LED 16 Supply Fault LED 17 Fire Protection Fault Disabled Test LED 18 Fire Protection Delay button and LED 19 Fire Protection On Acknowledged button and LED Sounder Fault Disabled Test LED Jog dial and function buttons 10 Reset button and LED 11 Panel Silence button and LED 20 Fire Routing Fault Disabled Test LED 21 Fire Routing Delay button and LED 22 Fire Routing On Acknowledged button and LED 12 Sounder Start Stop Button and LED For a detailed overview of front panel controls and indicators see Front panel controls and indicators on page 4 ZP2 F Series Fire Alarm Control Panel Operation Manual Front panel controls and indicators The following table gives an overview of the front panel controls and indicators Operational features described here are not available to all users Further information on control panel operation and access restrictions can be found in the topic Control panel operation on page 14 Table 2 Front panel controls and indicators Control LED LED colour Description Supply LED Green Indicates that the system is powered up General Test LED Yellow Indicates that one or more features or devices are being tested General Disable LED Yellow Indicates that one or more features or devices are disabled General Fault LED Yellow Indicates a general fault The fau
10. ZP2 F Series Fire Alarm Control Panel Operation Manual P N 501 405203 2 20 REV 2 0 ISS 03MAR11 Copyright Trademarks and patents Manufacturer Version Certification European Union directives A Contact information 2011 UTC Fire amp Security All rights reserved The ZP2 F Series name and logo are trademarks of UTC Fire amp Security Other trade names used in this document may be trademarks or registered trademarks of the manufacturers or vendors of the respective products UTC Fire amp Security Africa 555 Voortrekker Road Maitland Cape Town 7405 PO Box 181 Maitland South Africa Authorized EU manufacturing representative UTC Fire amp Security B V Kelvinstraat 7 6003 DH Weert Netherlands This document covers control panels with firmware version 2 0 or later CE 1999 5 EC R amp TTE directive Hereby UTC Fire amp Security declares that this device is in compliance with the essential requirements and other relevant provisions of Directive 1999 5 EC 2002 96 EC WEEE directive Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union For proper recycling return this product to your local supplier upon the purchase of equivalent new equipment or dispose of it at designated collection points For more information see www recyclethis info 2006 66 EC battery directive This product contains a battery that cannot be disposed of
11. an compatibility assessment of system components These control panels form part of a certified system as described by the EN 54 13 Standard when installed and configured for EN 54 13 operation as described by the manufacturer in the corresponding installation documentation Contact your installation or maintenance contractor to determine if your fire system is compliant with this standard European standards for electrical safety and electromagnetic compatibility These control panels have been designed in accordance with the following European standards for electrical safety and electromagnetic compatibility 26 EN 60950 1 EN 50130 4 EN 61000 6 3 EN 61000 3 2 EN 61000 3 3 ZP2 F Series Fire Alarm Control Panel Operation Manual ZP2 F Series Fire Alarm Control Panel Operation Manual 27
12. at the configured delay is active fire routing is activated when the configured delay elapses or when the delay is cancelled Fire protection A steady Fire Protection Delay LED indicates that a delay is enabled A flashing Fire Protection Delay LED during a fire alarm indicates that the configured delay is active fire protection is activated when the configured delay elapses or when the delay is cancelled 16 ZP2 F Series Fire Alarm Control Panel Operation Manual Note A fire alarm activated by a manual call point overrides any configured delay and activates fire routing or fire protection immediately if configured Viewing current events To view current event information press F1 Show events and then select the event type to view The event types available to this user level are Alarms Alerts Faults e Conditions Alerts are device alarms that require confirmation from another configured alarm event before an alarm is indicated at the control panel Conditions include all other system events Examples tests and disablements in the fire system Viewing support information To view support information configured by your installation or maintenance contractor press F3 Support Your installer or maintenance contractor may configure for example contact information or different messages to display in alarm and non alarm situations Note This information is only available if your installation or maintenance
13. contractor has included it in the fire system configuration ZP2 F Series Fire Alarm Control Panel Operation Manual 17 Operator level operation The operator level is protected by password security and is reserved for authorized users who have been trained to operate the control panel The default operator user password is 2222 This user level lets you e Perform all tasks described in Public level operation on page 16 e Reset the control panel e Manually start sounders stop sounders or restart stopped sounders e Enable or disable previously configured sounder fire routing and fire protection delays View system status reports e Change the operator password e Perform LED LCD buzzer and keyboard tests e View the alarm counter The Main menu The operator Main menu is shown below Figure 4 The operator Main menu Main menu D0 200 foo C Reports Alarm counter Password setup Logout Resetting the control panel To reset the control panel and clear all current system events press the Reset button System events that have not been resolved will continue to be reported after reset Caution Investigate all fire alarms and faults before resetting the control panel Manually starting sounders To manually start the sounders when the control panel is not in alarm press the Sounder Start Stop button Note Availability of this feature is subject to previous configuration Contact your installati
14. e display area with the notification details ZP2 F Series Fire Alarm Control Panel Operation Manual Indication of remote and local events on the LCD The local control panel ID is always displayed on the LCD see Figure 2 on page 7 If your control panel forms part of a fire network the event notification includes the panel ID reporting the event as follows e If the panel ID matches the local ID then the event relates to the local control panel e If the panel ID does not match the local ID then the event is reported by the remote control panel with the panel ID indicated Note Repeater panels are installed only in fire networks and by default have a network board installed Fire alarm control panels must have a network board installed to connect to a fire network Acoustic indicators The control panel uses the following acoustic indicators to highlight system events Indication Description The buzzer sounds continuously Indicates a fire alarm or a system fault The buzzer sounds intermittently long tone 1 Indicates all other faults The buzzer sounds intermittently short tone 1 Indicates a condition 1 Along tone is 50 ON and 50 OFF A short tone is 25 ON and 75 OFF Summary of conditions System events logged as conditions are shown below Table 4 System events logged as conditions Condition Description Tests A control panel feature or device is being tested Disablements A control pa
15. et with liquid products ZP2 F Series Fire Alarm Control Panel Operation Manual 23 Menu maps Operator level menu for fire alarm control panels Menu level 1 Menu level 2 Menu level 3 Test UI test Indicator test Keyboard test LCD test Reports Event log View all Attention required Revision Firmware revision Configuration revision Serial numbers Contact details Zone status Device status Panel I O status Output groups status Rules status Firenet status Alarm counter Password setup Change password Operator level menu for fire alarm repeater panels Menu level 1 Menu level 2 Menu level 3 Test UI test Indicator test Keyboard test LCD test Reports Event log View all Attention required Revision Firmware revision Configuration revision Serial numbers Contact details Panel I O status Firenet status Alarm counter Password setup Change password 24 ZP2 F Series Fire Alarm Control Panel Operation Manual Regulatory information European standards for fire control and indicating equipment These control panels have been designed in accordance with European EN 54 2 and EN 54 4 standards In addition they comply with the following EN 54 2 optional requirements Option Description 7 8 Output to fire alarm devices 1 7 9 1 Output to fire alarm routing equipment 2 7 9 2 Alarm confirmation input from fire alarm routing equipment 2 7 10 Output to fire protection equipment t
16. g and sounders activated by pressing the Sounder Delay button Sounder functionality is subject to previous configuration and depending on what your installation or maintenance contractor has selected silenced sounders may restart automatically if another alarm event is detected Contact your installation or maintenance contractor to confirm all configuration details for your site Enabling or disabling a previously configured sounder fire routing or fire protection delay To enable a previously configured sounder fire routing or fire protection delay press the corresponding Sounder Fire Routing or Fire Protection Delay button To disable the delay press the button again Note Availability of this feature is subject to previous configuration and its functionality may vary for each zone Contact your installation or maintenance contractor to confirm all configuration details for your site ZP2 F Series Fire Alarm Control Panel Operation Manual 19 Viewing reports To view system status reports for the control panel and connected devices select Reports from the Main menu Report information for this user level is shown in the table below Table 7 Reports available to operator users Report Description Event log Displays all alarm fault and condition events logged by the control panel Attention required Displays all devices reporting a fault condition Revision Displays your control panel software revision contro
17. l panel configuration revision and system boards serial number data Contact details Displays contact information for your installation or maintenance contractor subject to installer configuration Zone status 1 Displays the current status information for zones Device status 1 Displays the current status information for control panel devices Panel I O status Displays the current status information for the control panel inputs and outputs Output groups status 1 Displays control panel output groups Sounders fire routing fire protection or program that are currently active Rules status Displays control panel rules that are currently active Firenet status Displays the current status information for all control panels in the fire network 1 These reports are not available on repeater panels 2 A rule consists of one or more states combined by Boolean operators that are configured to trigger specific system actions after a specific confirmation time Rules are created by your installation or maintenance contractor using the configuration utility Note To check the firmware version of your control panel select Revision report and then select Firmware version Changing your password Use the Password setup menu to change your password To change your password 1 Select Password setup from the Main menu and then select Change password Enter your current password Enter and then confirm your new password Press F
18. lled the corresponding zone Disabled Test LED is steady if the corresponding zone is included on the zone board e The control panel buzzer sounds intermittently short tone For more information on the test press F1 Show Events and then select Conditions Low battery WARNING This is a critical indication and your property may not be fully protected If your control panel indicates low battery contact your installation or maintenance contractor immediately and ask them to restore power or if this is not possible to replace the batteries Low battery indicates that the control panel is running on battery power and that the remaining charge may be insufficient for continued operation Low battery is indicated as follows e The General Fault LED is flashing The Low battery LED is steady e Aan initial warning message indicating the low battery status is displayed on the LCD e If the power issue is not fixed the batteries will continue to discharge until a second warning message is displayed indicating that the control panel will shut down The buzzer sounds intermittently long tone When the batteries are completely discharged the control panel shuts down to protect the batteries and there are no further indications If power is re established before the control panel shuts down the control panel returns to its former status If not the control panel date and time must be reconfigured once power is restored Notes
19. lt LED for the corresponding device or feature also flashes Alarm LED Red Indicates a fire alarm A flashing LED indicates that the alarm was activated by a detector A steady LED indicates that the alarm was activated by a manual call point Fire Routing Red Cancels a previously configured delay as it counts On Acknowledged down and activates fire routing buton and EED A flashing LED indicates that fire routing has been activated A steady LED indicates that the fire routing signal has been acknowledged by the remote monitoring equipment Fire Routing Delay Yellow Enables or disables a previously configured fire button and LED routing delay Cancels a delay as it counts down and activates fire routing A steady LED indicates that a delay is configured and enabled A flashing LED indicates that a delay is counting fire routing is activated when the configured delay elapses or when the delay is cancelled Fire Routing Yellow Indicates a fire routing fault disablement or test A flashing LED indicates a fault A steady LED LED a indicates a disablement or a test Fire Protection Red Cancels a previously configured delay as it counts On Acknowledged button and LED down and activates fire protection A flashing LED indicates that fire protection has been activated A steady LED indicates that the fire protection signal has been acknowledged by the remote monitoring equipment ZP2 F Series Fire Alarm Control Panel Ope
20. n standards fire alarm status is indicated on the control panel LCD by zone and not by device When an alarm is reported in more than one zone the LCD displays two zone messages the first for the first zone to report an alarm and the second for the most recent zone to report an alarm as shown below Figure 3 Fire alarm indication on the control panel LCD L 27 04 09 16 05 0300 00 ol ALARM 09 01 08 10 15 70 PO1 20001 03 010 R amp D Dept 03 ALARM 09 01 08 10 14 d 010 PO1 20003 D11 010 Sales Dept Show events Language k dl Main menu Each zone message indicates e The zone identifier and description the timestamp and the device description of the first alarm reported in the zone e A counter with the total number of devices in alarm in the zone To see the details of the devices in alarm press F1 Show Events and select Alarms Then select the corresponding zone reporting the alarm A list of devices in alarm for the zone is displayed Additional fire alarm status indications are e The control panel Alarm LED flashes if the alarm is activated by a detector or is steady if it is activated by a manual call point e Ifa zone board is installed and the corresponding zone is included on the zone board then the zone alarm LED is flashing or steady depending on the source of the alarm e If a sounder delay has been enabled the Sounder Delay LED is steady e The Sounder Delay LED flashes while the delay is cou
21. nel feature or device is disabled Sounder fire routing and fire A sounder fire routing or fire protection delay is enabled or protection delays disabled Loop device not configured A loop device is detected that is not configured Input activation An input is activated subject to configuration Output group activation An output group is activated New node in the fire network A control panel has been added to the fire network ZP2 F Series Fire Alarm Control Panel Operation Manual 9 Condition Description Maximum loops exceeded in a network Maximum conventional zones exceeded in a network Prealarm Alert Configuration device connected Date and time not set Event log full The number of loops in a fire network exceeds the maximum allowed 32 The number of conventional zones in a fire network exceeds the maximum allowed 64 A device and corresponding zone is in prealarm A device is in alarm but the system is waiting for an additional alarm event to confirm the zone alarm A control panel configuration session is initiated via an external device PC laptop etc The system started but the date and time are not set The control panel event log is full In addition to the above the following system status events are also added to the event log but are not included in the control panel current events report Table 5 Other system status events added to the event log Event Description
22. nting The Sounder Start Stop LED indicates the Sounder Start Stop button status disabled not disabled and the status of the sounders see Table 2 on page 4 for more information e Ifa fire routing delay has been enabled the Fire Routing Delay LED is steady The Fire Routing Delay LED flashes while the delay is counting e When fire routing is activated the Fire Routing ON Acknowledged LED flashes If configured to do so by your installation or maintenance contractor a steady Fire Routing ON Acknowledged LED indicates that the fire routing signal has been acknowledged by the remote monitoring equipment ZP2 F Series Fire Alarm Control Panel Operation Manual 11 e Ifa fire protection delay has been enabled the Fire Protection Delay LED is steady The Fire Protection Delay LED flashes while the delay is counting e When fire protection is activated the Fire Protection ON Acknowledged LED flashes If configured to do so by your installation or maintenance contractor a steady Fire Protection ON Acknowledged LED indicates that the fire protection signal has been acknowledged by the remote monitoring equipment e Alarm information for the first and last zones to report an alarm is displayed on the LCD e The control panel buzzer sounds continuously Alarms activated by a manual call point always take priority over alarms activated by a detector When an alarm is activated by both devices the Alarm LED is steady Fault Fault stat
23. on or maintenance contractor to confirm your configuration details 18 ZP2 F Series Fire Alarm Control Panel Operation Manual Stopping sounders or restarting stopped sounders To stop the sounders press the Sounder Start Stop button To restart stopped sounders press the button again A steady Sounder Start Stop LED indicates that the sounders are active sounding A flashing Sounder Start Stop LED indicates that a configured sounder delay is counting down and that sounders can be silenced before activation by pressing the Sounder Start Stop button Notes To prevent the immediate silencing of sounders when an alarm is first reported the Sounder Start Stop button may be temporarily disabled for a preconfigured period of time when a configured sounder delay is counting down The default disable time for the Sounders Start Stop button is 60 seconds The disable time starts to count down when the control panel enters alarm status and the configured sounder delay starts During the configured disable time the Sounder Start Stop LED is off and the sounders cannot be silenced before activation by pressing the Sounder Start Stop button In the time between the end of the configured disable time and the end of the configured sounder delay when the Sounder Start Stop LED is flashing pressing the Sounder Start Stop button silences sounders before activation A configured sounder delay may still be cancelled while the delay is runnin
24. our username and enter your password by turning the jog dial clockwise or anticlockwise Press the jog dial to confirm each entry When a correct four digit password has been entered the LCD displays the Main menu for your assigned user level Note Your maintenance or installation contractor may have configured the control panel to remember the last login details entered To exit a restricted user level 1 Press F3 Logout from the Main menu 14 ZP2 F Series Fire Alarm Control Panel Operation Manual Operation controls and procedures Using the function buttons and the jog dial Use function buttons F1 to F4 and the jog dial see Figure 2 on page 7 to navigate the LCD menus to select menu options and to enter passwords and system information as shown below Entering passwords and Turn the jog dial clockwise or anticlockwise to enter passwords system information and other system information Press the jog dial to confirm an entry Selecting soft keys from the Press the function buttons F1 to F4 to select the corresponding LCD menu menu options Main menu Logout Exit etc Navigating and confirming Turn the jog dial clockwise or anticlockwise to select an option menu selections from the on screen menu Press the jog dial to confirm the selection The control panel ID on the LCD is white text with a dark background when the jog dial is active the control panel is waiting for input Configuration options The option
25. port information Silencing the buzzer To silence the control panel buzzer press the Panel Silence button A steady Panel Silence LED indicates that the buzzer was silenced Note Depending on the control panel configuration the buzzer may re sound for each new event reported Cancelling an active sounder delay a sounder delay is enabled and active counting down press the Sounder Delay button to cancel the delay and activate sounders immediately A sounder delay is indicated as follows e A steady Sounder Delay LED indicates that a delay is enabled e A flashing Sounder Delay LED during a fire alarm indicates that the configured delay is active Sounders are activated when the configured delay elapses or when the delay is cancelled A fire alarm activated by a manual call point overrides any configured delay and activates the sounders immediately Cancelling an active fire routing or fire protection delay If a fire routing or fire protection delay is enabled and active counting down press the corresponding ON Acknowledged or Delay button to cancel the delay and activate the feature immediately Fire routing and fire protection delay indications are shown in the table below Table 6 Fire routing and fire protection delay indications Delay type Delay indications Fire routing A steady Fire Routing Delay LED indicates that a delay is enabled A flashing Fire Routing Delay LED during a fire alarm indicates th
26. ration Manual Control LED LED colour Description Fire Protection Delay button and LED Fire Protection Fault Disabled Test LED Sounder Delay button and LED Sounder Fault Disabled Test LED Supply Fault LED Earth Fault LED Low Battery LED System Fault LED Sounder Start Stop button and LED ZP2 F Series Fire Alarm Control Panel Operation Manual Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Red Enables or disables a previously configured fire protection delay Cancels a delay as it counts down and activates fire protection A steady LED indicates that a delay is configured and enabled A flashing LED indicates that a delay is counting fire protection is activated when the configured delay elapses or when the delay is cancelled Indicates a fire protection fault disablement or test A flashing LED indicates a fault A steady LED indicates a disablement or a test Enables or disables a previously configured sounder delay Cancels a delay as it counts down and activates sounders A steady LED indicates that a sounder delay is configured and enabled A flashing LED indicates that a sounder delay is counting Sounders are activated when the configured delay elapses or when the delay is cancelled Indicates a sounder fault disablement or test A flashing LED indicates a fault A steady LED indicates a disablement or a test Indicates a power supply fault
27. s listed below are available when making configuration changes to the control panel for example changing the password The control panel configuration and configuration revision is only updated when configuration changes are applied by pressing F3 Apply The configuration revision change and timestamp are recorded in the Revision report and can be accessed at operator level see Viewing reports on page 20 Option Key Description Save F1 Select this option to save the current configuration change without applying it immediately Apply F3 Select this option to apply the current configuration change and all stored saved configuration changes The control panel will reset automatically Discard F4 Select this option to discard all stored saved configuration changes that have not been applied Exit F2 Select this option to exit the configuration process without storing or applying the current configuration change Note When updating multiple configuration settings we recommend that you save after each change and then apply all changes from the Main menu ZP2 F Series Fire Alarm Control Panel Operation Manual 15 Public level operation Public level operations are those that can be performed by any user No password is required to perform tasks at this level This user level lets you e Silence the buzzer e Cancel an active sounder fire routing or fire protection delay e View current events e View sup
28. tify the location of defective pixels 3 Press F2 Exit ZP2 F Series Fire Alarm Control Panel Operation Manual 21 View the alarm counter Select the Alarm counter option to view the total number of fire alarms recorded by the control panel The alarm counter value cannot be reset 22 ZP2 F Series Fire Alarm Control Panel Operation Manual Maintenance To ensure the correct functioning of your control panel and fire alarm system and to comply with all European regulations perform scheduled maintenance as described below Quarterly maintenance Contact your installation or maintenance contractor to carry out a quarterly inspection of the fire alarm system This inspection must test at least one device per zone and verify that the control panel responds to all fault and alarm events Annual maintenance Contact your installation or maintenance contractor to carry out an annual inspection of the fire alarm system This inspection must test all system devices and verify that the control panel responds to all fault and alarm events All electrical connections must be visually inspected to make sure that they are securely fastened that they have not been damaged and that they are appropriately protected Cleaning Keep the outside and inside of the control panel clean Carry out periodic cleaning using a damp cloth for the outside Do not use products containing solvents to clean the unit Do not clean the inside of the cabin
29. tion or maintenance contractor 6 ZP2 F Series Fire Alarm Control Panel Operation Manual LCD controls and indicators Figure 2 LCD controls and indicators O 10 11 10 18 43 00 00 PANEL 01 di FIRE DETECTION INSTALLATION C ac F1 0 F2 6 Fa ys F4 F2 F3 F4 Day night mode indicator System date and time Control panel network status stand alone networked repeater Current alarm fault and condition events counter Message display area Soft keys menu options linked to function buttons F1 F2 F3 and F4 Jog dial Function buttons F1 F2 F3 and F4 Local control panel ID in a fire network MN Oa F WYN ZP2 F Series Fire Alarm Control Panel Operation Manual Icons displayed on the LCD Icons displayed on the LCD are shown below Table 3 LCD icons and descriptions Icon Day mode network Day mode control panel Night mode network Night mode control panel Fire alarms Faults Conditions Stand alone Networked Repeater Detector alarm 1 Manual call point alarm 1 Description This icon indicates that the primary sensitivity mode setting for control panels in the fire network is day mode This icon indicates that the sensitivi
30. ty mode for the local control panel is day mode Other control panels in the fire network may have a different sensitivity mode setting This icon indicates that the primary sensitivity mode setting for control panels in the fire network is night mode This icon indicates that the sensitivity mode for the local control panel is night mode Other control panels in the fire network may have a different sensitivity mode setting The number beside this icon indicates the number of zones with an active fire alarm Alarm information for the first and last zones to report an alarm is displayed in the LCD message area The number beside this icon indicates the number of active faults Additional information is available by pressing F1 Show Events The number beside this icon indicates the number of active system conditions Additional information is available by pressing F1 Show Events For more information on system conditions see Summary of conditions on page 9 This icon indicates that the control panel is not connected to the fire network This icon indicates that the control panel is connected to the fire network This icon indicates that the control panel is configured to operate as a repeater and is connected to the fire network This icon indicates that the system has detected a detector alarm This icon indicates that the system has detected a manual call point alarm 1 These icons appear in the messag
31. us is indicated as follows e The General Fault LED is steady and the corresponding feature or device fault LED if there is one flashes e Mains and battery power faults are indicated by a flashing General Fault LED and Supply Fault LED Additional information about the fault is displayed on the LCD e Earth faults are indicated by a flashing General Fault LED and a flashing Earth Fault LED System faults are indicated by a flashing General Fault LED and a steady System Fault LED e Low battery faults are indicated by a flashing General Fault LED and a steady Low Battery LED e Additional information about the fault is displayed on the LCD e The control panel buzzer sounds intermittently long tone Note Always contact your installation or maintenance contractor to investigate the cause of a fault Disablement Disablements are indicated as follows e The General Disable LED is steady and the corresponding feature or device disable LED if there is one is flashing e If a zone board is installed the corresponding zone Disabled Test LED is steady if the corresponding zone is included on the zone board e The control panel buzzer sounds intermittently short tone For more information on the disablement press F1 Show Events and then select Conditions 12 ZP2 F Series Fire Alarm Control Panel Operation Manual Test Tests are indicated as follows e The General Test LED is steady e zone board is insta
32. ype A B and C 3 7 11 Delays to outputs 4 7 12 Dependencies on more than one alarm signal types A B and C 4 7 13 Alarm counter 8 4 Total loss of the power supply 8 9 Output to fault warning routing equipment 9 5 Disablement of addressable points 4 10 Test condition 4 1 Excluding repeaters and control panels operating in EN 54 2 Evacuation or NBN modes 2 Excluding repeaters control panels without fire routing and control panels with fire routing operating in NBN mode 3 Excluding repeaters and control panels without fire protection controls 4 Excluding repeaters Construction Products Directive CPD Certification C Certification body 0832 Certificate numbers ZP2 F1 ZP2 F1 FB ZP2 F1 SC 0832 CPD 1559 ZP2 F1 S ZP2 F1 FB S ZP2 F1 SC S ZP2 F2 ZP2 F2 FB ZP2 F2 SC 0832 CPD 1560 ZP2 F2 S ZP2 F2 FB S ZP2 F2 SC S EN 54 EN 54 2 1997 A1 2006 EN 54 4 1997 A1 2002 A2 2006 Year of manufacture The year and day of manufacture in the format YYDDD is included in the first five digits of your product serial number located on the product identification label ZP2 F Series Fire Alarm Control Panel Operation Manual 25 Manufacturer UTC Fire amp Security Africa 555 Voortrekker Road Maitland Cape Town 7405 PO Box 181 Maitland South Africa Authorized EU manufacturing representative UTC Fire amp Security B V Kelvinstraat 7 6003 DH Weert Netherlands EN 54 13 Europe