Home

UM PLFS LED - TEP Ex d.o.o.

image

Contents

1. 2008 and EN ISO IEC 80079 34 2011 The product is in compliance with the LV Directive 2006 95 EC The product is in compliance with the RoHS Directive 2002 95 EC The product is in compliance with EMC Directive 2004 108 EC and standards EN 55015 EN 61000 3 2 EN 61000 3 3 EN 61000 4 2 3 4 5 6 8 11 EN 61547 EN 55024 5 DEGREE OF PROTECTION AND TECHNICAL DATA Category and explosion protection type V II2G Ex de IIC T6 Gb II2D Ex tb IC T80 C Db Ambient temperature 40 C lt Ta lt 50 C Mechanical protection IP 66 according to EN 60529 1991 A 1 2000 category 1 Shock resistance IK 08 according to EN 62262 2002 Class of protection I protective earthing according to EN 60598 1 2008 Type examination certificate EXA 14 ATEX 0028X Certificate EXA 14 ATEX 0028X Mark C 2465 Category and II 2G Ex de IIC T6 Gb explosion protection II 2D Ex tb INC T80 C Db Ambient temperature 40 C lt Ta lt 50 C Mechanical protection IP 66 Resistance to shock Class of protection Rated voltage Type 1 Rated voltage Type 2 Frequency Rated power Power factor LED driver LED light source Rated luminous flux Estimated service life Failure rate Terminals IK 08 I PE protective earthing 90 305 V AC 50 60Hz or 127 431 V DC 12 60 V DC 50 60 Hz 50W cos d gt 0 96 LED driver PLFS LED 50 HSG 70 24 MEANWELL Co Ltd with OVP OCP OTP protection BXRA
2. 40E4500 H 00 Brigelux 5000 Im at tamb 25 C 50 000 working hours at tamb 40 C LOOF10 terminals for phase and neutral conductors L1 L2 L3 N max 2 x 2 5 mm sol r sol s f terminal for protective earthing PE max 2 x 6 mm sol s f terminal for external grounding equipotential bounding max 2 x 6 mm sol s f torque screw for terminals is 1 2 Nm TEREX ao USER MANUAL FOR EXPLOSION PROTECTED tel 049222900 fax 049 426 450 PENDANT LIGHT FITTING TYPE e mail tepex tepex hr www tepex hr PLFS LED 50 Cable entries Date 1 2014 two entries ISO 25 Ex e M25 Glands and plugs pressure screw for the threaded nut of the cable glands is 2 5 Nm and for intermediate glands and plugs is 3 5 Nm Screws for the terminal chamber screw M5x2 ZA 4 8 tightening Torque 1 5 Nm Weight 7 4 kg 6 LUMINAIRE CHARACTERISTICS POLAR CURVE based on photometric light fitting test report 150 i 150 1 al TF ii wA i T288 If A T T Fi Fi LL i T 7 4 LSZ J 120 A SATH TTT AG yy _ 120 NAVAL A EES Fi A A a A 4 64 l f i Oe A il teed iis MA 4i N T if ie l ae p A ii Se WA WU if a l on Ne ie ee N is Wi a La Uy oe ae ph CE a a 7 EEN e 90 i _ c0 180 C30 210 C60 240 C90 270 7 TYPES PLFS LED 50 Basic type Rated voltage 1 90 305 V AC 127 143 V DC 2 12 60 V AC DC TEPE U
3. NING gt DONOTOPEN WHEN AN lt EXPLOSIVE ATMOSPHERE IS PRESENT 16 5 A S 4g Marking label with the technical data outside Type 1 Type 2 67 5 a _ 67 5 7 A B l IEPEx E rEx C HR 10090 Zagreb 2465 HR 10090 Zagreb 2463 PLFS LED 50 1 EXA 14 ATEX 0028X m PLFS LED 50 2 EXA 14 ATEX 0028X g 90 305VAC 127 431 VDC50 60Hz 50 W 3 72 60 VDC 50 W cost 0 96_ Ex l2G ExdellC T6 Gb Ex l2G ExdellC T6 Gb X 12D Ex tb IliC T80 Db IP66 X 12D Ex tb IlIC T80 Db IP66 40 C lt Tamb lt 50 C P OKK 40C lt Tamb lt 50 C P OKK WARNING DO NOT OPEN WHEN ENERGIZED WARNING DO NOT OPEN WHEN ENERGIZED Ls 60 a B 60 H Marking label with the technical data inside Type 1 Type 2 67 5 _ _ 67 5 _ TEPE CE 0 TEPE CE HR 10090 Zagreb 2465 HR 10090 Zagreb 2465 r PLFS LED 50 1 EXA 14 ATEX 0028X Pa PLFS LED 50 2 EXA 14 ATEX 0028X g 90 305VAC 127 431VDC 50 60Hz 50 W g 269 VDE 50 W eost 0 96 Ex 2G ExdellC T6 Gb Ex 2G ExdellC T6 Gb X 12D Ex tb IlIC T80C Db IP66 12D Ex tbIIIC T80 Db IP66 L40 CT lt Tamb lt 50 P OKK P L40 C lt Tamb lt 50 C P OKK O i i
4. SER MANUAL FOR EXPLOSION PROTECTED tel 049222900 PENDANT LIGHT FITTING TYPE fax 049 426 450 PLFS LED 50 e mail tepex tepex hr vo Repe Number Date 1 2014 8 MOUNTING AND INSTALLATION The light fitting comes standard with Ex e cable gland M25 for cable 6 15mm Ex e plug M25 and without protection grid or accessories for suspension mounting Mounting and installation of light fitting is carried out according to the labeled technical data and the additional manufacturer s instructions national rules and regulations as well as the generally recognized rules of technique Only under this conditions the explosion protection that is committed with type certificate will be confirmed The quality of the used materials ensures compliance in the standard industrial atmosphere For special requirements please contact the manufacturer Opening Ex d terminal chamber should be done by unscrewing the blocking screw M5x25 Unused entry should be closed by Ex e ATEX II 2G II 2D certified plug It is necessary to check that the cable is clean and undamaged Particular attention should be paid to the selection of the inner sealing rings of the cable glands to the outside diameter of the cable Pressure screw and intermediate gland have to be tightened with nominal torque Electrical connection should be performed in Ex e chamber by connecting cables on Ex e terminals L N PE by tightening the terminal screws with nominal torque Potentia
5. TEPE USER MANUAL FOR EXPLOSION PROTECTED tel 049222900 PENDANT LIGHT FITTING TYPE fax 049 426 450 PLFS LED 50 e mail tepex tepex hr wo tepex hr Number Date 1 2014 CONTENT L Manufacturer 1 2 General safety informations 1 3 Purpose 2 4 Product compliance 2 J Degree of protection and technical data 2 6 Luminaire characteristics 3 T Types 3 8 Mounting and installation 4 9 Dimensions 4 10 Spare parts and accessories 5 11 Inspection maintenance repair and overhaul 5 12 Responsibility and authorization 5 13 Storage and transport 6 14 Manufacturer s warranty 6 15 Marking 6 1 MANUFACTURER TEP Ex d o o Prilaz dr Franje Tu mana 6 HR 49210 ZABOK Tel 385 49 222 900 Fax 385 49 426 450 Web www tepex hr 2 GENERAL SAFETY INFORMATIONS warnine The user manual contains basic information about the product Mounting installation usage and maintenance should be carried out under this user manual to provide and ensure safe operation within the nominal characteristics This user manual complement national Regulation and Standards The responsible person shall ensure their implementation Failure off implement this user manual can reduce explosion protection and endanger people property and the environment Any improper and illegal actions as well as non compliance with the provisions of this user manual excludes all responsibility by manufacturer side Before installation commissioning Caref
6. for the product and the warranty and the manufacturer s declaration of conformity becomes invalid 12 RESPONSIBILITY AND AUTHORIZATION This instruction is the basic information about the product It is complementing with the corresponding national laws and regulations Production use certification and supervision are determined at the national level a Regulations concerning equipment and protective systems intended for use in potentially explosive atmospheres EU directive 94 9 EC ATEX 94 b Regulations on minimum requirements for safety and health protection of workers and technical inspection of facilities equipment installations and equipment in hazardous areas EU directive 1999 92 EC ATEX 137 The responsible person shall ensure their implementation at the working facility TEPE USER MANUAL FOR EXPLOSION PROTECTED tel 049222900 PENDANT LIGHT FITTING TYPE fax 049 426 450 PLFS LED 50 e mail tepex tepex hr vo Repe Number Date 1 2014 13 STORAGE AND TRANSPORT Transportation and storage of the light fitting is only allowed in the original cardboard box 14 MANUFACTURER S WARRANTY The manufacturer provides a Warranty on the product for a period of one year under the provisions of this User manual and the Law This statement has the force of Warranty sheet 15 MARKING LED light fitting PLFS 50 is marked with the marking label with the technical data and a warning label Warning label 50 WAR
7. fy Protection grid 130 framework set set PLFS T PLFS T Ex e terminal PLES 10 150 External PLES chamber reflector 20 100 cover set set PLFS T lamp Ex e cable holder for PLES gland SO25 SPU 25 lamppost 20 120 set o 1 1 2 set PLFS T bracket Ex e plug SPC 25 z for wall PLFS ISO25 mounting 20 130 set set 11 INSPECTION MAINTENANCE REPAIR AND OVERHAUL Inspections are carried out in accordance with IEC 60079 17 2007 C 1 2008 general and special conditions of manufacturer and users Regulations and includes inspection of parts on which the explosion protection depends especially e the housing terminal chamber glass protective framework cable gland plugs protective glass and seal are without rupture and damage e the glands plugs terminals screw of the terminal chamber and locking bolt on the glass protective framework are fastened with nominal torque In to the parts for maintenance and repair belongs all the parts provided by the manufacturer and indicated in the list of spare parts All other procedures have the character of repair All the repairs are performed by the manufacturer or the manufacturer s authorized personal and the original parts have to be provided according to the product documentation all in accordance with EN 60079 19 2011 Overhaul and modifications are not allowed If repair or any other procedure are performed on the product by unauthorized person all producer responsibility
8. l equalization external earthing terminal have to be connected to external ground circuit Insulation resistance is routine factory tested over 100 MQ 500 V DC Dielectric strength is routine factory tested on 1500 V AC between neutral N and protection earth PE and phase L and protection earth PE Testing between phase N and neutral L is not allowed X j a er e A S A Z N 7 N vA N N E F a 9 DIMENSIONS lt 1 a O16 M25x1 5 7H 89 M20x1 WARNING 4 DO NOT OPEN WHEN AN 4 LOS PRESENT IS P T SEN 5 i Ar i A 1 r amp bal TEPE USER MANUAL FOR EXPLOSION PROTECTED tel 049222900 PENDANT LIGHT FITTING TYPE fax 049 426 450 PLFS LED 50 e mail tepex tepex hr ww teper hr Number Date 1 2014 10 SPARE PARTS AND ACCESSORIES a PLFS LED 50 The glass PLFS LED PLFS LED 50 PLFS LED 10 protective 10 120
9. ully read all instructions Execute proper training of responsible personnel Check that the contents of these instructions is fully understandable by the responsible personnel Make sure that all the requirements and national Regulations as well as all special security measures are applied In lack of understanding Contact the manufacturer During operation Ensure that this user manual and other work instructions are available to the responsible staff at all times Check the implementation of these instructions and all other safety user s instructions USER MANUAL FOR EXPLOSION PROTECTED TEREX ao tel 049222900 PENDANT LIGHT FITTING TYPE fax 049 426 450 PLFS LED 50 e mail tepex tepex hr vo tepe Number Date 1 2014 3 PURPOSE Explosion protected pendant light fitting type LED PLFS 50 is intended for general lighting in industrial areas with potentially explosive atmosphere Zones 1 2 21 22 in accordance with EN 60079 10 1 2 2009 The quality of the materials ensures compliance with standard functionality in standard industrial atmosphere For special requirements please contact the manufacturer 4 PRODUCT COMPLIANCE The product complies with the ATEX Directive 94 9 EC and standards EN 60079 0 2012 EN 60079 1 2007 EN 60079 7 2007 EN 60079 31 2009 The product has been developed manufactured and tested according to the existing state of technique accordance with the standards EN 9001