Home

SMART COMPACT UPS

image

Contents

1. GAMATRONIC Our Power Your Confidence SMART COMPACT UPS User s Manual BT NIE Bee enna Release 1 7 February 2013 GAMATRONIC ELECTRONIC INDUSTRIES LTD 17 Hartom St P O B 45029 Jerusalem 91450 Israel Tel 972 2 588 8222 Fax 972 2 582 8875 Email info gamatronic co il Website www gamatronic com 2MUXSMART E Gamatronic Electronic Industries Ltd Har Hotzvim Industrial Park 17 Hartom St PO Box 45029 Jerusalem 91450 Israel Tel 972 2 588 8222 Fax 972 2 582 8875 Email info gamatronic co il Website www gamatronic com The equipment described in this document is not intended to be used in connection with any application requiring fail safe performance unless the application design includes appropriate redundancy This exclusion includes but is not limited to the direct operation of any life support system or any other system whose failure could lead to serious injury death environmental damage or mass destruction Copyright 2013 by Gamatronic Electronic Industries Ltd All rights reserved worldwide Any representations in this document concerning the performance of Gamatronic s product s are for informational purposes only and are not warranties of future performance either express or implied Gamatronic s standard limited Warranty which accompanies its sales contract or order confirmation form is the only warranty offered by Gamatronic Electronic Industries Ltd in relation thereto Gamatronic El
2. The battery is not properly charged This 1 couldtbe due fp Charge the UPS battery for atleast 8 hours by leaving it on and connected to the ac power mains but with no load Turn off unnecessary load devices and The UPS does not 1 An extended power outage provide backup for the expected length 2 Overload too many devices connected N to the UPS i of time E disconnect them from the UPS 3 The battery is approaching the end of its 3 Replace the battery useful life The red LED is lit and Disconnect the power cable from the UPS and the UPS emits a UPS failure contact your UPS salesperson for support continual beep information 8 Troubleshooting Smart Compact UPS Gamatronic Electronic Industries Ltd User Guide 7 SERVICE AND REPAIRS Gamatronic maintains a team of service technicians repair laboratories and an ample inventory of spare parts dedicated to the service and repair of our products When service is required it will be performed either at the customer s site or in one of our laboratories according to the judgment of our technician and the specifics of the service agreement between the customer and Gamatronic In regards to service oral agreements have no standing Service shall be provided gratis during the warrantee period on the condition that the UPS has been properly maintained and a written record has been kept of any maintenance performed on the system The initial w
3. 4 3 on page 6 2 OVERVIEW Smart Compact UPS Gamatronic Electronic Industries Ltd User Guide 2 3 Features of the SMART COMPACT UPS e Transfer to backup mode is microprocessor controlled e Automatic detection of ac input frequency 50 60 Hz e Reverts to power saving sleep mode when the connected devices are not in use e Automatic Voltage Regulation for steady voltage e USB port for connection to a computer see section 5 4 e Can protect a modem or phone line from voltage spikes e Capable of cold starting from the internal battery when there is no ac mains voltage e Automatic self test at startup and immediate notification of low battery and overload conditions e Protected against overload and against short circuit in the attached equipment e Immediate notification of ac power failure via LED and audible alarm 2 4 Included with your SMART COMPACT UPS e Two power cables with male female ends for connecting a computer and a monitor screen to the UPS e AUSB USB cable for connection between the PC and the UPS and a software program on CD ROM for installation on the PC which together make it possible to perform an orderly unattended shutdown of the computer in the event of an ac power failure e A warrantee certificate e Auser guide this book Smart Compact UPS OVERVIEW 3 User Guide Gamatronic Electronic Industries Ltd 3 FRONT AND REAR PANEL OF THE UPS The UPS features shown in Figures 1 an
4. All specifications are subject to change without prior notice RECYCLING INFORMATION CAUTION Do not discard waste electrical or electronic equipment WEEE or used batteries in the trash For proper disposal contact your local recycling or hazardous waste center 1 1 1 2 2 1 2 2 2 3 2 4 3 1 4 1 4 2 4 3 4 4 5 1 5 2 5 3 5 4 Table of Contents SAFETY PRECAUTIONS eite etie t acetals itu Catan 1 DO S icc atecereccieecee dene T 1 DOWNS recientes teet cleeo desc c ct ccwetcawatccscaceaucsccdecschaecsueaecsuatotustonseaccsaees 1 OVERVIEW ee P EERE 2 Introduction and specifications eeeeeeeeeeeee 2 In case of ac mains power failure eeeeeeererneee 2 Features of the SMART COMPACT UPS eene 3 Included with your SMART COMPACT UPS s 3 FRONT AND REAR PANEL OF THE UPS eene 4 Audible alarms 51r eR nne aaraa aar aaia naaa a ERR ERU 5 INSTALLATION INSTRUCTIONS eeeeeeeeeeeeeeeeeeenee entente 6 Site preparat OT 56e eee tee cet ede ee 6 Access to tlie DPS uit tt es ere 6 Before first use the UPS Battery must be charged 6 Installing the SMART COMPACT UPS esee 6 OPERATION INSTRUCTIONS 3 Iit tie teo reri on enn dias De 7 Starting the UPS uie en uoc
5. B ports 2 Place the supplied CD ROM in the computer s CD ROM reader The installation wizard will start up automatically on most computers If it does not start automatically display the CD ROM s directory and run the setup file 3 Follow the instruction of the software wizard to complete the software installation 4 Simulate a power outage by holding the On Off button for six seconds Verify that the orange LED lights up this indicates that the UPS is working in battery mode Verify that the computer performs an orderly shutdown after the time you have defined in the shutdown software has elapsed 6 TROUBLESHOOTING The UPS advises you of exceptional condiditions by means of its LEDs and a beeping alarm Table 3 outlines some of the most common problems and their solutions Table 3 Troubleshooting Problem Probable cause Possible solution The UPS does not 1 Inputac cable not properly connected to 1 Properly connect the input ac cable to the ac start up even though the UPS orto the ac power lines socket and to the UPS the input ac poweris 2 The fuse on the UPS s input line has 2 Replace the UPS s input fuse with a fuse of OK failed the same type and rating When the ac power returns charge the UPS battery for at least 8 hours by leaving it on and connected to the ac power but with no load The UPS starts up The UPS battery voltage is low due to an but the red LED is lit extended ac power outage
6. Eoi ILS 7 Turning orf the UPS oc iata 7 Testing the UPS batteries eere 7 Installation and use of the monitoring software 8 TROUBLESHOOTING etta ti o Et cc ticis 8 SERVICE AND BEPAIRBS n terete eae qe onte Di eor sta teense eesti 9 SYSTEM SPECIFICATIONS 5 p ric oia iis oce ebat nere eee 10 This page left blank deliberately Gamatronic Electronic Industries Ltd User Guide 1 SAFETY PRECAUTIONS 1 1 Do s e Read this manual carefully before operating the UPS e Review these safety precautions to avoid damaging users or equipment e Install the UPS in a stable clean dry and well ventilated location Do not expose the UPS to direct sunlight or to sources of high heat e Leave at least 20 cm of clearance space between the ventilation holes of the UPS and other objects or walls e The UPS must be grounded to the building s grounding system Ensure that the power outlet you use is properly grounded e The UPS contains batteries Improper treatment of the UPS can result in electric shock even when the UPS is not connected to the ac power mains e Ensure that foreign objects do not enter the UPS s ventilation holes e Allow only qualified technicians to service the UPS There are no user serviceable components Do not try to repair it yourself A WARNING Appropriate precautions should be taken during inspection and servicing there is a
7. arrantee period can be extended by a written service agreement between Gamatronic and the customer Without a written agreement Gamatronic is under no obligation to provide service after expiration of the initial warrantee period Gamatronic will not be responsible for maintenance or changes to the UPS that are performed by an agent without written authorization from Gamatronic Smart Compact UPS Service and repairs 9 User Guide Gamatronic Electronic Industries Ltd 8 SYSTEM SPECIFICATIONS MODEL SCE 650 SCE 750 SCE 1000 SCE 1500 CAPACI TY 650 VA 750 VA 1000 VA 1500 VA INPUT Voltage 230 Vac Voltage range 25 96 25 96 Frequency 50 60 Hz auto sensing OUTPUT Voltage 230 Vac 10 96 Frequency 50 60 Hz 0 5 Hz Transfer time 2 ms 4 ms typical Voltage regulation Automatic buck and boost regulation Sockets 4 IEC type BATTERY Type Sealed lead acid maintenance free Capacity 12 Vdc Recharge time 4 Hrs to 9096 of full capacity Protection Self diagnostics at power up PROTECTI ON Spike protection 350 Joules over 2 ms Unit input Fuse for overload and short circuit protection Overload Automatic shutdown when load over 110 96 for 60 s or over 130 96 for 5 s Short circuit Input fuse protection UPS output cuts off immediately ALARM Battery back up Beep every 4 s Battery low Beep every 1 s Overload Continuous b
8. aser to prepare the warranted item for return to Gamatronic or Gamatronic s agent The information contained in this document is proprietary and is subject to all relevant copyright patent and other laws protecting intellectual property as well as any specific agreement protecting Gamatronic s rights in the aforesaid information Neither this document nor the information contained herein may be published reproduced or disclosed to third parties in whole or in part without the express prior written permission of Gamatronic In addition any use of this document or the information contained herein for any purposes other than those for which it was disclosed is strictly forbidden Gamatronic reserves the right without prior notice or liability to make changes in equipment design or specifications Information supplied by Gamatronic is believed to be accurate and reliable However no responsibility is assumed by Gamatronic for the use thereof nor for the rights of third parties which may be affected in any way by the use thereof This document may contain flaws omissions or typesetting errors no warranty is granted nor liability assumed in relation thereto unless specifically undertaken in Gamatronic Electronic Industries Ltd standard limited Warranty Information contained herein is periodically updated and changes will be incorporated into subsequent editions If you have encountered an error please notify Gamatronic Electronic Industries Ltd
9. cludes built in line conditioning known as AVR Auto Voltage regulation the best technology for protecting your PC against all power disturbances including power blackouts power surge and power sag Your choice of the SMART COMPACT UPS means you are working smart protecting your PC against power irregularities and protecting yourself against data loss 2 2 Incase of ac mains power failure In the event of a power failure the SMART COMPACT UPS supplies stable backup power to your computer or other connected device from internal batteries There is no interruption of power to your computer The SMART COMPACT UPS informs you of the loss of ac power by lighting the orange LED on the front panel and beeping every four seconds The length of time that the SMART COMPACT UPS can supply backup power depends on the power usage of the attached computer or other load and on the level of battery charge In the case where the UPS is connected to a typical PC computer and the UPS battery is fully charged you can count on at least three to five minutes of backup enough time to save your work and shutdown the computer in an orderly fashion Printers typically draw large amounts of power as do many household appliances The SMART COMPACT UPS is not designed to provide large amounts of power so do not connect a printer or household appliances to the UPS Be aware that you need to charge the UPS batteries before your first use of the UPS See section
10. d 2 are explained in Table 1 1 Red LED battery low overload 2 Green LED power on normal operation 3 Orange LED battery mode 4 Power ON OFF push button Figure 1 Front view of the Smart Compact UPS Ac input Input fuse Surge protection for modem phone line USB connector Four uninterruptable power outlets IEC type Figure 2 Rear view of the Smart Compact UPS 4 Front and rear panel of the UPS Smart Compact UPS Gamatronic Electronic Industries Ltd User Guide Table 1 UPS controls indicators and connectors EN NEM OU 1 Red LED When lit indicates an overload condition or a battery low condition 2 Green LED When lit indicates that ac power is present and the UPS is operating normally filtering the ac power and ready in the event of an ac failure 3 Oranae LED When lit indicates that an ac power failure has occurred and that the UPS is i 9 supplying power from its battery 4 On Off switch Turns the UPS on and off Also used to cold start the UPS from battery power when there is no ac power present 5 Ac input connector The ac input power cord is connected here Protects the UPS in the event of a short circuit or other case of input power overload If it becomes necessary to replace the fuse the new fuse must be of the same rating 7 RJ11 ports for These two female RJ11 ports one for input and one for output enable modem phone line you
11. ectronic Industries Ltd Gamatronic warrants the products it manufactures to be free from defect for a period of one calendar year from the date of invoice including the date of invoice Gamatronic s liability is limited to repairing or replacing any defective parts in the equipment under warranty Gamatronic reserves the right to determine whether the repair work shall be performed at Gamatronic s factory at the customer s premises or at an alternate site The customer must obtain authorization from Gamatronic before returning any parts or equipment to Gamatronic for repair or replacement Any items returned to Gamatronic must be sent freight prepaid Gamatronic is not responsible for any damage to the product due to unauthorized repair work misuse or abuse of the product or force majeure If the UPS is delivered without batteries Gamatronic is not responsible for any damage or malfunction due to incorrect wiring of the batteries Gamatronic is not liable for and the Purchaser waives any right of action it has or may have against Gamatronic for any consequential or special damages arising out of any breach of warranty and for any damages that the Purchaser may claim for damage to any property or injury or death to any person arising out of its purchase or the use operation or maintenance of the subject product This warranty includes parts and labor however Gamatronic shall not be responsible for any labor subcontracted or performed by the Purch
12. eep INDI CATORS Green LED Power on normal operation Red LED Battery low overload Yellow LED Battery mode GENERAL Standard features Auto sensing of input frequency Cold start function UPS auto restart Green mode inverter auto shutdown when no load Telephone modem protection RJ11 USB communications interface Auto shutdown and monitoring software Compatible with Windows 95 NT4 0 98SE ME 2K XP Server 2003 Vista Linux Redhat 7 0 7 3 and Mandrake 8 2 Novell 4 x 5 1 ENVI RONMENT Altitude 5000 m Temperature 0 C 50 C Humidity 0 90 non condensing Audible noise 40 dBA 1m STANDARDS Noise suppression CE EN50091 FCC Class B VCCI BSMI Surge suppression IEEE587 amp EN61000 3 2 Safety EN50091 1 DI MENSI ONS HxWxD 202 x 110 x 275 mm Weight net 4 4 kg 5 3 kg 5 9 kg 6 4 kg 10 All specifications are subject to change without prior notice System Specifications Smart Compact UPS
13. nto the UPS s protected power output If the computer monitor is connected directly to the ac power line unplug the monitor from the ac mains and plug it in to one of the protected outlets on the rear of the UPS See Figure 2 on page 4 and Table 1 on page 5 6 Installation instructions Smart Compact UPS Gamatronic Electronic Industries Ltd User Guide 5 OPERATION INSTRUCTIONS 5 1 Starting the UPS 5 1 1 Performing a regular warm start 1 Start up the UPS by pressing and holding the On Off button on the front panel for four seconds The UPS performs a self check and begins to operate using the ac input power 2 Verify that the green LED on the front panel of the UPS is lit 3 You can now turn on the computer or other device and use it as normal knowing that it is now protected against voltage surges and sudden ac cutoff 5 1 2 Performing an emergency cold start In the event of a power outage that occurred when the UPS was off the UPS can be started on battery power to supply a few minutes of power to the computer or other load device Be aware that in cold start mode in order to conserve battery power the UPS performs no self test at startup The actual length of time the load device can be operated in this mode depends on the power consumption of the load device and the battery charge level To perform a cold start of the UPS press the On Off button for 6 seconds 5 2 Turning off the UPS 1 Turn off
14. risk of lethal electric shock The battery cabinet contains 12 Volt batteries that provide high voltage even when the UPS is not connected to the mains 1 2 Don ts e Do not open the cover under any circumstances e Donotinsert any objects through the ventilation holes e Do not place objects on the top of the UPS e Do not move the UPS while it is operating e Donotturn the UPS upside down during transportation e Do not turn on the UPS when it is disconnected from the ac power mains e Do not disconnect the UPS from the power mains until the UPS is turned OFF e Do not place the ac power supply cord where it will be subject to strain or abuse e Do not turn on the UPS when it is disconnected from the ac power mains e Inthe event that the UPS is in storage for an extended period of time recharge the UPS batteries by connecting the UPS to the ac power mains for 8 hours e Do not use any liquid cleaners to clean the UPS Use a dry cloth only A WARNING A Do not touch the battery terminals of external batteries with bare hands Smart Compact UPS Safety Precautions 1 User Guide Gamatronic Electronic Industries Ltd 2 OVERVIEW 2 1 Introduction and specifications Gamatronic is proud to present to you the line interactive SMART COMPACT UPS Uninterruptible Power Supply The SMART COMPACT UPS provides high quality protection for a PC a network workstation or any small Internet connected device The SMART COMPACT UPS in
15. st free close to the ac power supply and to the device to be protected 2 Ensure at least 20 cm of clearance space between the ventilation holes of the UPS and other objects and walls 3 Ensure that the UPS s ventilation holes do not become obstructed 4 2 Access to the UPS All UPS controls and indicators are on the front panel All input and output cable connections are on the rear panel of the UPS 4 3 Before first use the UPS Battery must be charged Before first use of the UPS its batteries must be charged To charge the UPS batteries 1 Plug the UPS into the ac power main 2 Turn on the UPS by pressing the ON OFF button for 6 seconds 3 Leave the UPS in this state for at least 8 hours with no devices connected to it 4 After 8 hours the UPS is ready for use 4 4 Installing the SMART COMPACT UPS To prepare the UPS for first use 1 Ensure that the ac power mains voltage is either 110 Vac or 230 Vac 2 Connect the UPS ac input to the ac power main For this purpose you can disconnect the computer s ac input cord from the computer and connect it to the UPS see Figure 2 on page 4 3 Using one of the supplied power cords connect the computer s ac input socket to one of the UPS s power outlets on the rear of the UPS See Figure 2 on page 4 and Table 1 on page 5 4 If your computer monitor the screen draws power from the computer it is already protected by the fact that you have plugged the computer i
16. the computer or other load devices connected to the UPS 2 Press the On Off button on the UPS front panel for about 6 seconds The orange LED lights up then the red LED Following this the UPS shuts off 5 3 Testing the UPS batteries When the UPS is operating you can simulate an ac power outage and cause the UPS to work off of its batteries by pressing and holding the On Off button for six seconds Verify that the orange LED comes on this indicates that the UPS is working in battery mode It is recommended that you conduct the battery test when a computer or other device is connected to the UPS and turned on This verifies that the UPS supplies power properly when there is no ac power Smart Compact UPS Operation instructions 7 User Guide Gamatronic Electronic Industries Ltd 5 4 Installation and use of the monitoring software The Smart Compact UPS is delivered with a disk containing software that can be used to automatically perform an orderly shutdown of a computer in the event of an ac mains failure The software also enables you to monitor the status of the Smart Compact UPS from a computer The software is compatible with the following operating systems e WINDOWS 95 NT4 0 98SE ME 2000 XP VISTA 32bits VISTA 64bits e LINUX Redhat 7 0 7 3 Mandrake 8 2 e NOVELL 4 X 5 1 1 Connect one end of the supplied USB USB cable to the USB port on the UPS rear panel Connect the other end of the cable to one of the computer s US
17. to protect a single modem line or telephone line from power surges 8 USB tvpe A port Used to connect the UPS to the computer if it is desired to use the VP p unattended shutdown feature when a power failure occurs 9 Ac output sockets Supply stabilized ac power and uninterrupted power in the event of an ac power failure 6 Ac input fuse 3 1 Audible alarms The SMART COMPACT UPS has an audible alarm it beeps to indicate any of several problem conditions Table 2 explains how to understand the alarm The alarm can be silenced by pressing the ON OFF button for 3 seconds and then releasing it The alarm will automatically be reactivated in the event of a new alarm condition Table 2 Interpreting the audible alarm Type of beep Meaning Every 4 seconds The UPS is supplying power from the UPS battery due to a failure or other irregularity in the normal ac power On certain models the alarm can be silenced by pressing and holding the On Off switch for 2 seconds Every 1 second Battery voltage is low Continuous Overload condition Smart Compact UPS Front and rear panel of the UPS 5 User Guide Gamatronic Electronic Industries Ltd 4 INSTALLATION INSTRUCTIONS 4 1 Site preparation The SMART COMPACT UPS is designed to operate in a wide variety of work environments To ensure long and satisfactory service from your UPS 1 Choose a location for the UPS that is well ventilated and du