1. shock and fire hazards please do not plug or unplug the cord with wet hands During maintenance and cleaning please unplug the unit PROPER GROUNDING REQUIRED To minimize shock and fire hazards make sure that the unit is properly grounded PROHIBITED Do not attempt to remove or repair any component unless instructed by factory Make sure that the unit is not resting on or against the electrical cord and plug To minimize personal injury do not hang on the doors Do not store any flammable and explosive gas or liquids inside the unit Do not attempt to alter or tamper with the electrical cord Do not set the desired temperature out of the recommended temperature range Do not store corrosive or high acidity items or food in the unit MEMO RETAIN THIS MANUAL FOR FUTURE REFERENCE Please read the entire manual carefully before installation and operation If certain recommended procedures are not followed warranty claims will be denied Notice Iceblue reserves the right to make changes in design and specifications without prior notice MODEL SERIAL PURCHASE DATE ALLCATER NSW 1 18 STENNETT RD INGLEBURN NSW 2565 TEL 612 9618 0828 FAX 612 9618 0668 VIC 77 19 MAIN RD CLAYTON SOUTH VIC 3019 TEL 613 9546 3016 FAX 613 9546 3017
2. COMMERCIAL UNDERBAR FREEZER OWNER S MANUAL UBZ SERIES This manual contains important information regarding your new ICEBLUE unit Please read the manual thoroughly prior to equipment set up operation and maintenance Failure to comply with regular maintenance guidelines outlined in this manual may void warranty MUST READ Limited warranty Allcater warrants to the original purchaser the Iceblue unit sold and all parts thereof to be free from defects in material or workmanship under normal use and service for a period of 1 year from the date of purchase Please read the attached original warranty certificate for details EXCLUSION FROM WARRANTY _ Normal start up maintenance adjustments and cleaning 2 Damage caused by improper installation of the Iceblue unit as outlined in this manual Labor charges resulting from the inaccessibility of the Iceblue cabinet Damage to parts due to misuse abuse neglect or accidents Premium labor rates due to holidays overtime travel time mileage etc not specifically authorized by Allcater prior to service 6 repairs due to modifications to the Iceblue unit or refrigeration system including remote location of compressor s door hinge reversal etc 7 Claims for indirect or consequential damages including food spoilage or product loss 8 Damage due to faulty or incorrect power supply floods storms or other acts of nature 9 Glass breakage lights and fair te
3. amage If damage is discovered immediately file a claim with the delivery freight carrier CABINET LOCATION GUIDELINES 1 Install the unit on strong and leveled surfaces Unit may make unpleasant noises if surface is uneven Unit may malfunction if surface is uneven 2 Install the unit in an indoor well ventilated area Unit performs more efficiently in a well ventilated area Make sure to maintain a clearance of 24 above the unit Outdoor use may cause decreased efficiency and damage to the unit 3 Avoid installation in high humidity or dusty area Humidity could cause unit to rust and decrease efficiency of the unit Dust collected on condenser coil will cause unit to malfunction Clean the condenser at least once a month with a brush or clean cloth Malfunction due to dirty condenser will void warranty 4 Select a location away from heat and moisture generating equipment High ambient temperatures will cause the compressor to overwork leading to higher energy bills and gradual breakdown of the unit Malfunction due to high ambient temperature will void warranty ELECTRICAL Please ensure that the required voltage of the compressor is being supplied at all times Low or high voltage can detrimentally affect the refrigeration unit and thereby void its warranty All units should be plugged into a grounded and properly sized electrical outlet with appropriate over current protection Please refer to the electr
4. ar and wear ae WARRANTY SERVICE To insure warranty coverage a qualified service company authorized by Allcater must perform the warranty repair Please contact the Allcater service department for assistance All service calls must be authorized by a qualified Allcater employee WARRANTY CLAIMS All claims for labor or parts must be made directly or passed through to Allcater All claims should include model number of the unit the serial number of the cabinet proof of purchase date of installation and all pertinent information supporting the existence of the alleged defect In case of warranty compressor the compressor model tag must be returned to Allcater along with above listed information If this is ignored we will decline the warranty claim or delay the warranty claim until information is available INSTALLATION IMPORTANT PLEASE READ BEFORE INSTALLATION 1 Ifthe unit has recently been transported please let unit stand still for a minimum of 24 hours before plugging it in 2 Make sure that the unit drops down to desired temperature before products 3 Make sure that there is proper ventilation around the unit 4 Make sure all accessories are installed i e shelves shelf clips casters before plugging the unit in 5 Please read through the operation owners manual Lack of maintenance or misuse of the unit will VOID warranty 6 Before you start to install your Iceblue unit carefully inspect it for freight d
5. high acidity should not be stored in the fridge because it will corrode piping around the water box and condensing unit WARNING DISCONNECT POWER CORD BEFORE CLEANING ANY PARTS OF THE UNIT TROUBLE SHOOTING Before requesting any service on your Iceblue unit please check the following points Service calls resulting from lack of maintenance or misuse is not covered under watranty and also may void warranty Please note that this guide serves only as a reference for solutions to common problems SYMPTOM POSSIBLE CAUSE CORRECTIVE ACTION Compressor not Fuse blown or circuit breaker Replace fuse or reset circuit running tripped Breaker Power cord unplugged Cabinet in defrost cycle Plug in power Cord Set thermostat to lower temperature Wait for defrost cycle to finish Condensing unit runs for long periods of time Excessive amount of warm product placed in cabinet Prolonged door opening or door ajar Door gasket not sealing properly Dirty condenser coil Allow adequate time for product to cool down Ensure doors are closed when not in use Avoid opening doors for long periods of time Ensure gaskets are snapped in completely Remove gasket and wash with soap and water Check condition of gasket and replace if necessary Clean the condenser coil Unplug unit and allow coil to defrost Make sure thermostat is not set too cold Ensure that door gaskets are sealing properly Cabinet Therm
6. ical requirements on the unit serial tag located inside the unit Please make sure that your unit has its own dedicated outlet Do not use an extension cord REGULAR MAINTENANCE CLEANING THE CONDENSER COIL For efficient operation it is important that the condenser surface be kept free of dust dirt and lint Iceblue recommends cleaning the condenser coil and fins at least once per month Clean with a commercial condenser coil cleaner available from any kitchen equipment retailer Or just use a brush and soft cloth CLEANING THE FAN BLADES AND MOTOR If necessary clean the fan blades and motor with a soft cloth If it is necessary to wash the fan blades cover the fan motor to prevent moisture damage CLEANING THE INTERIOR OF UNIT When cleaning the cabinet interior use a solvent of warm water and mild soap Do not use steel wool caustic soap abrasive cleaners or bleach that may damage the stainless steel surface Wash door gaskets on a regular basis preferably weekly Simply remove door gasket from the frame of the door soak in warm water and soap for thirty 30 minutes dry with soft cloth and replace Check door gaskets for proper seal after they are replaced Periodically remove the shelves and pilasters from the unit and clean them with mild soap and warm water To remove the pilasters firstly remove the shelves and shelf clips then unscrew the pilaster with a screwdriver and remove HIGH ACIDITY Items that are of
7. ostat set too warm Set thermostat to lower temperature is too Blocking airflow temperature warm Excessive amount of warm products placed in cabinet Fuse blown or circuit breaker tripped Dirty condenser coil Prolonged door opening or door ajar Re arrange product to allow for proper airflow Make sure there is at least four inches of clearance from evaporator Allow adequate time for product to cool down Replace fuse or reset circuit breaker Clean the condenser coil Ensure doors are closed when not in use Avoid opening doors for long periods of time Cabinet is noisy Loose part s Tubing vibration Water box too close to piping Located and tighten loose part Ensure tubing is free from contact with other tubing or components SAFETY WARNING Please pay close attention to the safety notices in this section Disregarding these notices may lead to serious injury and or damage to the unit SOW OR Won ATTENTION To minimize shock and fire hazards be sure not to overload outlet Please designate one outlet for your unit Do not use extension cords Do not put your hands under the unit when the unit is required to be moved When the unit is not in use for a long period of time please unplug the unit from the outlet After unplugging the unit wait at least 10 minutes before re plugging it Failure to do so could cause damage to the compressor UNPLUG CORD To minimize