Home

Network Data User Manual

image

Contents

1. Depth Speed Sensor L Sensor Sensor Up to a maximum of four Network DATA units maybe used in an integrated Network Instrument System where the total number of units does not exceed twenty ALARMS AND THE NETWORK DATA UNIT The Network DATA unit can display the depth alarm information that has been set on either Network DEPTH or Network QUAD units It is NOT able to change the alarm values or enable disable them The Network DATA unit has its own internal alarm buzzer that will sound when an alarm condition is met and transmitted over the entire Network System It is silenced by pressing any of the five keys in the lowest row of any Network display unit The Network DATA unit can display the alarm value that has been set or OFF if it is not enabled The following are examples of a depth alarm displays See USING THE DEPTH KEY for all the available alarm displays USING THE SPEED KEY Press the SPEED key to cycle through the speed options If there is no speed data the Network DATA unit will display OFF when the SPEED key is pressed The speed information is only displayed when the Network DATA unit is connected to a Network QUAD or Network SPEED unit The units in which the speed and log information is display is set on the main display unit When speed data is available the following can be displayed SPEED MX SP KT AV SP TRIP NM LOG NM Boat speed in Knots KT or
2. Network DEPTH Network LORAN Network QUAD Network NAV Network WIND Network CHART Network TACK Network DATA AUTOPILOTS COMMUNICATIONS Network PILOT Network VHF INTRODUCTION TO NETWORK DATA NETWORK DATA DISPLAY UNIT The Network DATA unit is a repeater of available networked information supplied from other Network Instruments via the system network The information is presented on a large back lit Liquid Crystal Display LCD It has no sensor interfaces as all data is passed to the unit via the system network cables The unit is capable of transmitting NMEA 0183 v1 5 data via the network cables The Network DATA unit has its own internal buzzer that sounds when an alarm condition is met and received via the system network from other Network units The row of five keys are used for selecting the displayed information when the appropriate unit and its sensor is connected to the Network DATA unit e SPEED Current maximum and average speed SPEED DEPTH WIND OPTIONS LIGHTS e DEPTH Water depth and depth alarms WIND Apparent wind speed and angle True wind speed and angle VMG OPTIONS Heading DR distance DR course Temperature Timers Battery Volts LIGHTS Three levels of illumination and off SYSTEMS USING NETWORK Network SPEED DEPTH and WIND main units with DATA repeater for all functions Network QUAD main unit with DATA unit repeaters for depth and speed functions Wind Sensor
3. KT TWA True wind angle in degrees TWS KT True wind speed in knots KT VMG KT Velocity Made Good in knots KT AWA and TWA are indicated to Port or to Starboard by the position of the displayed legend PORT STARBOARD USING THE OPTIONS KEY Press the OPTIONS key to cycle through the options If there is no data available the Network DATA unit will display OFF when the OPTIONS key is pressed The information is only displayed when the Network DATA unit is connected to Network PILOT and Network SPEED or Network QUAD units When connected to the appropriate units the following can be displayed HEADING Compass heading supplied from Network PILOT s internal fluxgate compass Dead Reckoned Distance in NM or M DRC M Dead Reckoned Course in degrees Magnetic M TEMP C Sea water temperature in degrees Celsius C or Fahrenheit F TIMER Timer Hours and Minutes in large digits Seconds in small digits LAP Lap timer reset on main unit BATTERY Battery volts USING THE LIGHTS KEY The Network DATA Display unit has 3 levels of illumination and off controlled by the LIGHTS key LIGHTS 0 OFF LIGHTS 3High LIGHTS 2Medium LIGHTS 1Low It also changes the illumination level of the key legends The LIGHTS key is always illuminated so even in complete darkness the key can be located 10 NETWORK ALARMS The Network DATA unit has an internal buzzer that will sound when an alarm conditio
4. MPH MH Maximum boat speed since the last reset of the trip log Average boat speed since the last reset of the trip log The trip log value in Nautical Miles NM or Statute Miles M The stored log in Nautical Miles NM or Statute Miles M USING THE DEPTH KEY Press the DEPTH key to cycle through the depth options If there is no depth data the Network DATA unit will display OFF when the DEPTH key is pressed The depth information is only displayed when the Network DATA unit is connected to a Network QUAD or Network DEPTH unit The depth units and the alarm values are set on the main unit When depth data is available the following can be displayed DEPTH M Water depth in metres M feet FT fathoms FA DEP A M Deep water alarm The display will show the value or OFF SHA A M Shallow water alarm The display will show the value or OFF ANC A M Anchor watch alarm The display will show the values alternatively or OFF USING THE WIND KEY Press the WIND key to cycle through the wind options If there is no wind data the Network DATA unit will display OFF when the WIND key is pressed Apparent wind functions are displayed when Network DATA unit is connected to a Network WIND unit true wind and VMG also require a Network SPEED unit When wind and speed data is available the following can be displayed AWA Apparent wind angle in degrees AWS KT Apparent wind speed in knots
5. number Pressing the keys will not silence this alarm In some cases the fault can be cleared by switching off the instruments at the supply waiting a few moments and then switching on again If this does not clear the fault the error number should be recorded Switch off the supply and disconnect the faulty unit Return it with the error number to your dealer for servicing 12 INSTALLATION The display heads are supplied with a clip in mounting bracket which allows for easy installation access from behind is not necessary to secure the unit in place However to prevent theft and permanently fix the unit in position locking studs and thumb nuts are supplied SITING THE UNIT All Network Instruments are designed for mounting on or below deck A mounting position should be selected where they are Easy to read by the helmsman On a smooth and flat surface At least 100mm 4 from a compass Accessible from behind for fitting locking studs if required MOUNTING THE UNIT Use the cutting template supplied to mark the centres of the holes for the self tapping screw the fixing stud holes and the mounting bracket The template allows 4mm 5 32 between adjacent units for the suncover increase this distance if required to maximum of 60mm 2 3 8 between units or 180mm 3 1 8 between centres For greater distances between units extension cables are available Use a 70mm 2 3 4 diameter hole cutter for the mo
6. CONTENTS sie dieses den oe ed in eal 1 GENERAL INTRODUCTION TO B amp G NETWORK 2 INTRODUCTION TO NETWORK DATA 3 EXAMPLE SYSTEMS USING NETWORK DATA 4 ALARMS AND THE NETWORK DATA UNIT 5 USING THE SPEED KEY paroi aret pora ran pont utente 6 USING THE DEP TH KEV T USING THE WIND KEY esee 8 USING THE OPTIONS KEY nr rnnt 9 USING THE LIGHIS KEY uen uta pee s 10 NETWORK ALARMS 11 FAULT AND ERROR 12 INSTALLATION M 13 14 SITING THE UNIT erp need one 13 MOUNTING THE UNIT etico ctos ciae eoo arto oat 13 SPECIFICATION iir tester de ben teo oen 15 CONDITIONS OF WARRANTY GENERAL INTRODUCTION TO B amp G NETWORK The B amp G Network range of instruments is designed to be used as individual units or connected together to form an integrated navigational system A single network cable is used to carry data and power between units The latest technology and screened cables throughout the Network System ensure the ultimate protection from interference between units and other systems All Network instruments can be linked to Network PILOT Network CHART Network GPS or Network LORAN receivers or via NMEA 0183 v1 5 to other navigational equipment INSTRUMENTS NAVIGATIONAL AIDS Network SPEED Network GPS
7. idity Up to 95 RH Sealing Fully sealed front suitable for bulkhead cockpit mounting Vented barrel to prevent condensation ELECTRICAL Power Supply 12V DC nominal 10 to 16V Operating Current 40mA typical 100mA illuminated Protection Connect via external fuse or circuit breaker CABLES AND CONNECTIONS Connection to adjacent units is via cable tails fitted with either a plug or a socket Extension cables are available from your dealer The cable tails carry power and NMEA data between units ALARM Internal audible alarm NMEA OUTPUT SENTENCES IIHDM Heading IIVHW Speed and Heading IIDBT Depth IIVWR Apparent wind angle and speed SIIMTW Sea temperature 15
8. n is met on a Network unit that has alarm functions ie Network DEPTH and Network QUAD for depth alarms and Network PILOT for Watch Alarm and Off Course alarms The unit will also display which alarm is activated To silence the internal alarm and return the display to normal operation press any of the five keys DEPTH ALARM DISPLAY Depth alarms can be set for the following Shallow water Deep water Anchor Watch Check your Network DEPTH or QUAD unit to see which alarm is activated NETWORK PILOT ALARM DISPLAYS The Watch Alarm is a count down timer with is activated at the end of the preset count down period The display alternates between the messages above The Off Course alarm is activated when the boat deviates off course by a preset amount The display alternates between the messages above 11 FAULT AND ERROR MESSAGES NETWORK PILOT FAULT DISPLAY If Network PILOT should have a fault the autopilot computer unit will send a message to all other Network Display Units The Network DATA unit will alternately display the follow message the actual fault will have to read from the Network PILOT Display unit UNIT INTERNAL ERRORS In the unlikely event that your Network DATA unit should develop an internal error the unit will sound it s alarm continuously and the display will show an error
9. unting bracket hole Use a 2 9mm for the self tapping screw holes Use a 5mm 3 32 drill for the locking stud holes e Secure the mounting bracket to the bulkhead with the self tapping screws supplied Fit the rubber sealing gasket around the mounting bracket e Screw the locking studs into the back of the display head if required Carefully pass the cable tails through the mounting bracket hole connect the cables to the main units Clip the display head into the mounting bracket e Secure the instrument with the thumb nuts supplied 13 INSTALLATION DATA Display Unit Side view of unit Rear view of unit M0 0 25 0 65 0 SY BEG Network DATA Locking stud fixing 110 0 Network Network Power connector connectar Mounting Bracket 82 0 Gasket isplay Un Q AE fit around the MA mounting bracket 70mm hole_ 222 Bulkhead i k eee ap Mounting B Tad Gasket ounting Bracke Q Salf tapping screws All Dimensions in millimeters 14 SPECIFICATION PHYSICAL PARAMETERS Constuction High impact ABS plastic Window Acrylic Display Back lit Liquid Crystal Display Large Digits 28 6mm 1 12 Small Digits 11 5mm 0 45 Dimensions 110x110 x 25 4mm 4 4 1 Requires 65mm 2 6 depth behind bulkhead for display barrel Weight 0 3 kg 0 66lbs ENVIRONMENTAL Operating Temp 10 to 55 C 93 RH 14 to 131 F 93 RH Storage Temp 25 to 70 C 95 RH 13 to 158 F 93 RH Hum