1. 1 Safety Guidance This chapter provides important safety information related to the use of ORFC Software 1 1 Intended Use Digital intraoral x ray imaging system is intended for dental radiographic examination and diagnosis of diseases of the teeth jaw and oral structures The device is to be operated and used by dentists and other legally qualified professionals The system is intended to be used in hospitals and clinics by trained personnel under the direction of doctors The system is intended for adult patients but paediatric and pregnant women with caution o 1 2 Warnings and Cautions In order to use the software safely and effectively and avoid the possibility of system failure firstly be familiar with the operation method of Windows and read the user manual in detail and be sure to be familiar with the proper operation method of ORFC Software and sensor The following WARNING and CAUTION precautions during the operation of the system must be paid more attention to NOTE 1 This system is not intended for home use 2 The pictures and windows in this manual are for reference only Page 1 of 62 ORFC Software User Manual 1 2 1 Safety Warnings WARNING 1 Failure to follow the safety instructions for operating the instrument and system could endanger the patient The manufacturer accepts no liability for damages resulting from improper use 2 The system should be installed by qualified service engineers D
2. Page 38 of 61 ORFC Software User Manual koala server 192 168 1 185 4 2013 Send Cancel Burn Export a Click button to enter export interface as follows 201403121515 Execute Create ISO EN Burn Disc HL DT ST DVDRAM GUT7 Cancel Standard Compression Export Select create ISO will generate the ISO file in the specified location and data can be used for recording If the computer itself supports recording you can select the Burn Disc and insert a blank disc The following section is used to export data supported formats include DICOM DICOMDIR BMP and JPG 8 4 Remote List Remote list configuration is familiar with study list Select Server cc button to bring up the server selection dialog box select the appropriate server and click OK to connect the corresponding server aiming to refresh the display list Page 39 of 61 ORFC Software User Manual Name AET164 m IPAddr 4921681164 S4 Port 3012 Cancel Image Browser Double click to check the list of records or click the button to enter the image browser interface And has checked into the picture from a different view the image is downloaded from the server needs to wait to load the complete display 9 Image Browser Image browsing interface of two modes image editing and image browser mentioned in study list part 9 1 Image editing Modify images including window width and position adjustm
3. gt Processors Disable gt sg Sound video and game Uninstall p gt Storage controllers js gil System devices Scan for hardware changes 4 Universal Serial Bus cont 3 Generic USB Hub MENE Generic USB Hub dan F Intel R 7 Series C216 Chipset Family USB Enhanced Host Controller 1E26 Intel R 7 Series C216 Chipset Family USB Enhanced Host Controller 1E2D Lan fF Intel R USB 3 0 eXtensible Host Controller Intel R USB 3 0 Root Hub de USB Composite Device USB Composite Device USB Root Hub 4 Update driver dialog and then choose Browse my computer for the driver software Page 17 of 61 ORFC Software User Manual a r J Update Driver Software USB lt gt Serial Converter How do you want to search for driver software gt Search automatically for updated driver software Windows will search your computer and the Internet for the latest driver software for your device unless you ve disabled this feature in your device installation settings Browse my computer for driver software Locate and install driver software manually 5 Choose the location of the driver file and then click Next Update Driver Software USB lt gt Serial Converter Browse for driver software on your computer Search for driver software in this location D Fussen SensorDriver Include subfolders gt Let me pick from a list of device d
4. Bluetooth Radios Broadcom Bluetooth 4 0 gt gil Computer gt Disk drives Display adapters DVD CD ROM drives a Human Interface Devices p 4g IDE ATA ATAPI controllers b 234 Imaging devices gt 2 Keyboards Memory technology driver Mice and other pointing devices Monitors KY Network adapters Js Other devices jij USB lt gt Serial Converter fy USB lt gt Serial Converter b E Processors b ak Sound video and game controllers p KE Storage controllers p lll System devices p 7 Universal Serial Bus controllers 3 Choose the USB lt gt Serial Converter and the click the right mouse button select Update Driver Software File Action View Help e P cder NG Computer Management Local 4 4 Fantasy Ting a System Tools gt P Batteries gt Task Scheduler 4 Bluetooth Radios gt Ga TE i W More Actions D Shared Folders gt gJ Computer gt Local Users and Groups gt Disk drives gt Performance gt MM Display adapters Al Device Manager gt 3 DVD CD ROM drives a Storage gt 05 Human Interface Devices t Disk Management gt IDE ATA ATAPI controllers D Es Services and Applications gt Imaging devices gt ED Keyboards gt Memory technology driver b A Mice and other pointing devices gt E Monitors gt i Network adapters 4 b Other devices fi USB lt gt Serial Conve i Ge USB lt gt Serial Conv Update Driver Software
5. 1 System Management Click the Ed to enter the System Management including the machine configuration working listings storage configuration remote configuration IO information IO tools service settings The machine configuration FUSSEN2D D FNImage Test No debug VKeyboard General debug DX Detail debug AE Title Full debug 127 0 0 1 English 30000 IO No limit 5 GB18030 1024 All 1 gt System parameters Including detectors drive storage directory and detectors files Detector drive Select FUSSEN2D FUSSEN2E FUSSEN 2F select TEST under simulated conditions as the experimental simulation driven collection Main storage directory Specify the patient check image path on the local computer storage space Detector File Fussen sensor configuration file 2 gt The machine parameters Page 49 of 61 3 gt 4 gt 5 gt ORFC Software User Manual Hospital Name The current system hospital name which will be stored in the DICOM attributes of the image Hospital Prefix as a local registration number prefix Such as hospitals prefix DX then automatically generated number is DXxxxxxxx registration form such as DX000170 DX000170 Device Name corresponding DICOM standard of AETitle this device used to identify the device IP Address The IP address of the machine Delay Time network connection time Record time check the records to identify locally saved time and after this tim
6. dicom query receive SCP you can configure this page Q R Server enabled whether enable as a dicom Q R SCP DICOM Q R SCP configuration as a dicom Q R SCP IPAddr IP address Port port number BufferSize cache size Initial count initial count of child process or thread Lifetime lifetime of child process or thread Server mode process mode or thread mode Auto start whether auto start the Q R Service Client parameter Q R SCU parameter AETitle AE title of Q R SCU IPAddr AE title of Q R SCU Port port number of Q R SCU Test button test the communication with Q R SCU Page 56 of 61 ORFC Software User Manual Add button add a Q R SCU Update button update the selected Q R SCU Delete button delete the selected Q R SCU 11 2 study management Click the study button to enter the examination management interface including pre processing post processing and orientation Pre Process Post Process Orientation Pre Process Speckle noise Sensor type 600 Cancel 1 gt Pre processing Pre Process Speckle noise Sensor type 600 Speckle for speckle noise filtering done by nuclear size Sensor Type 600 and 900 2 gt post processing Image dynamic range adjustment multi scale enhancement noise reduction There two methods Musica and Picasso Muisca parameters Page 57 of 61 ORFC Software User Manual Post Proce Method Musica Dynamic range Enhance factor Eq factor Detail level Detail enhanc
7. distributors for lyear The warranty is void in the case of a Damage caused by handling during shipping b Subsequent damage caused by improper use or maintenance c Damage caused by alteration or repair by anyone not authorized by Fussen d Damage caused by accidents e Replacement or removal of serial number label and manufacture label If a product covered by this warranty is found to be defective because of defective materials components or workmanship and the warranty claim is made within the watranty period Fussen will at its discretion repair or replace the defective part s free of charge Fussen will not provide a substitute product for use when the defective product is being repaired 13 2 Contact information If you have any question about maintenance technical specifications or malfunctions of devices contact your local distributor Alternatively you can send an email to Fussen service department at info fussenct com Page 61 of 61 P N 11 54 0009 FUSSEN Smile in your life EC REPRESENTATIVE Well Kang Limited The Black Church St Mary s Place Dublin 7 Ireland TEL 353 1 4433560 FAX 353 1 6864856 E mail AuthRep CE marking eu MANUFACTURE Fussen Technology Co Ltd 3F 10 Building Tongfuyu Industrial Zone Taoyuan Street Nanshan District Shenzhen China TEL 86 755 21670890 FAX 86 755 21670890 E mail info fussenct com www fussenct com
8. hide patient information tagging angle distance etc Pseudo color e Organization lens magnifying the local o Single point of gray value Page 44 of 61 ORFC Software User Manual Me PR Image display adjustment click to pop up image adjustment interface Image style Normal Contrast Enhancement Process Undo Advanced processing reprocess images 1f you are not satisfied with current treatment original image should exist Process Page 45 of 61 ORFC Software User Manual Co Actual Size Adjust the window width on aside Zoom 9 2 Image Browse Image browse can view all images of a patient within a course When entering the image browsing interface tooth template will mark filmed teeth of the current patient as shown below TIE Aldea A penn From the template we can see that teeth 26 is filmed tooth click on the filmed image of teeth the tooth that contains all of the images and thumbnail image will be displayed below the template which arranged in reverse chronological order Page 46 of 61 ORFC Software User Manual ulik likte ug 1 i 2014 05 21 10 Image acquisition This section describes some of the operations and precautions during image acquisition Click e button to start the acquisition The countdown screen will display a total of 90 seconds to wait for X ray When the status bar displays Ready to acquire imag
9. the setup language and then click OR Page 6 of 61 ORFC Software User Manual Select Setup Language rws Select the language to use during the aiis installation 2 2 Welcome page please click Next gt F fr mg Setup ORFC Pl Welcome to the ORFC Setup Wizard This will install GRFC version 3 3 0 1 on your computer It is recommended that you dose all other applications before Click Next to continue or Cancel to exit Setup i 2 3 Select destination location and then click Next gt Page 7 of 61 ORFC Software User Manual r wa Setup ORFC Where should ORFC be installed a Setup will install ORFC into the following folder To continue dick Next If you would like to select a different folder dick Browse At least 134 4 MB of free disk space i 5 2 4 Select start menu folder and then click Next gt 7 wa Setup ORFC Select Start Menu Folder Where should Setup place the program s shortcuts i Setup will create the program s shortcuts in the folowing Start Menu folder To continue dick Next If you would like to select a different folder dick Browse ussen ORFC Don t create a Start Menu folder i 2 5 Select additional tasks and then click Next gt Page 8 of 61 ORFC Software User Manual r ig Setup ORFC Select Additional Tasks Which additional tasks should be performed Select the additional t
10. the system performance may be declined 2 Powering detectors every day to an hour and a half until the probe reaches a steady state and then to film the operation If conditions allow do not turn off detector power in any case which can guarantee the stability of the detector temperature and other aspects Page 31 of 61 ORFC Software User Manual WARNING If proper protective measures or practices are not strictly followed the X ray system will cause harm to the patient and operator 8 Examination management This part of the patient examination management including work list study list and remote list Work list Patientll PatientID Name Gender Modality Age Accession Apply time Doctor name 8 1 work list In the management interface click the work list button to enter work list This list includes patients who have been registered but have not yet studied Page 32 of 61 ORFC Software User Manual Selected field Height PatientID Weight Name Birthday Gender Description Modality Cancel Diagnoses Apply time U p Doctor name Down Align left List information The work list includes patient ID name sex age birthday modality description and so on All information can be configured to display by clicking EZA button to configure In the configuration dialog you can add optional patient information in optional fields column to selected column which stands for current patient information
11. will have to repeat this process for any new boards If you have multiple boards to use with the same computer we recommend installing the drivers for each one before you shut down or restart your computer 7 Basic check operation Part 4 describes how the main console to check on the implementation of a patient Basic checking operation before confirmation sensors are connected to a computer is good and commissioning Console is the main part of the digital X ray imaging system to interact with users Console can Login system Locally incorporated add a new patient edit existing patient information for this patient Sensor parameter adjustment Restart sensor driven Exposure to obtain X ray images Browse images delete save or export After finish filming a check of all images turn off this check Select the output destination image Get the task list from RIS HIS Page 25 of 61 ORFC Software User Manual Access to patient images from the remote server for diagnostics Modify the patient information of the image 7 1 Boot and login system Boot and login system is mainly completed by the following steps I Turn on UPS power supply that will power the computer console 2 Turn on the high voltage generator 3 Turn on the console host and login system 4 Start the console software and log in NOTE Console host best shut down once a day to make the system fully reset otherwise the performance of the system m
12. 3 Legend and ME ENE EE 4 gt EST 01100 EEEN E EE EEE EE EEE 5 3 l System Feature OV TEEN SE EE ES 5 3 2 Work conditions SUGGESTION Lauen ndededme ne bukbadnaonmdsdnedrden sordadsdedrdssed bunken 6 4 Installation EEE NE NE SSN 6 5 Install the driver by manual srrrnnrvrnonvvrronnvrrrnnvrrnnnvrrrnnrvrrnnnversnnvnrnsnnnssnnnnsssnnnsssnnvessnnvesnnns 16 6 Disable driver signature enforcement on Win rrrnrnrnnnrrrnnnvvrnnnnvrrnnnvnrnnnrnrnnnvvrrsnnversnnvennnns 20 rs Sop le Go 05 1 OU EE EE EN 25 7 1 Boot and login SYSICM snssoscisnsscnsiansconsdonsasnaionseaasonsdaaadvncsaasisntagnsdsecsasisovssaadensaansleneaseds 26 7 2 Patient Registration rrrrrrnrnnrrnrnonrvvrronnrvrrrnnnvvnrsnnnvnrsennnnnsssnnvnsssnnnnnsssnnrnssssnnvnsssnnnnesssnne 28 PUEIA EE 30 EN 31 8 Examination MANAGEMENMN ccssccccsssscccsssseccesssecessseeccssneeeessseecesseusesesseeeeseseeeesseaeeeeenes 32 TV 32 SJ ACO Uh Io EE 35 EE Ve AE EE TE A ames 36 JE 211 10 WAG EEE NE 39 ME BONN eee 40 AEE Ii 40 2 WAS DIONS EN ES EEE 46 10 Image JO UO ee 47 11 System Management EEE 48 Ta SYSTEM 100 EE A A EE EEEE 49 VM TATT 57 11 3 User Management rnnrrrnnnrorannrorennvvrsnnnvnsnnnresennrerennnnrsnnnsnssnnresennvesennressnnnsrsnnnsnsnnnsesenn 59 EE Ta eg EEE EE EE 60 EV NTN 61 PIM 61 13 2 Contact information rrrronrrrrrnnnrrrrnnnrrrrnnnrrrrnnrrvrnnrrrrnnserrrnassenrnnssenrnnssennnnssennnnssennnnnsee 61 ORFC Software User Manual
13. Driver Installation Wizard This wizard helps you install the software drivers that same computers devices need in order to work To continue click Next 2 8 8 Install page please do not click Cancel Page 13 of 61 ORFC Software User Manual Device Driver Installation Wizard The drivers are now installing Please wait while the drivers install This may take some time to complete 2 8 9 If install the sensor driver on windows 7 a dialog about windows security will show up please choose Install this driver software anyway i Windows Security i amp Windows can t verify the publisher of this driver software Don t install this driver software You should check your manufacturers website for updated driver software for your device gt Install this driver software anyway Only install driver software obtained from your manufacturer s website or disc Unsigned software from other sources may harm your computer or steal information W See details PS The dialog windows security will show up twice 2 8 10 Completing page and then click Finish If installed successfully the completing page looks like next picture Otherwise the driver installed unsuccessfully Page 14 of 61 ORFC Software User Manual Device Driver Installation Wizard Completing the Device Driver Installation Wizard The drivers were successfully installed on this computer You can now connect your
14. N USB Serial Converter X in Universal Serial Bus controllers of the device manager Page 19 of 61 ORFC Software User Manual m x el 5 Computer Management File Action View Help e Boder RG W Computer Management Local a System Tools gt gill Computer Task Scheduler gt Disk drives Event Viewer gt MM Display adapters 3 More Actions gt Shared Folders gt DVD CD ROM drives Local Users and Groups 05 Human Interface Devices 8 Performance 4g IDE ATA ATAPI controllers Device Manager Imaging devices 4 Storage gt Keyboards f Disk Management Memory technology driver ms Services and Applications gt R Mice and other pointing devices Monitors MY Network adapters JP Ports COM amp LPT JP Dental X Ray Sensor Port COM41 1108 Dental X Ray Sensor Port COM42 QD Processors lj Sound video and game controllers lt Storage controllers gt gli System devices PE Universal Serial Bus controllers fl FUSSEN USB Serial Converter A m FUSSEN USB Serial Converter B Generic USB Hub Generic USB Hub he F Intel R 7 Series C216 Chipset Family USB Enhanced Host Controller 1E26 ve F Intel R 7 Series C216 Chipset Family USB Enhanced Host Controller 1E2D i bee F Intel R USB 3 0 eXtensible Host Controller l Intel R USB 3 0 Root Hub y USB Composite Device USB Composite Device USB Root Hub U
15. SB Root Hub 6 Disable driver signature enforcement on Win 8 If install the sensor driver in windows 8 you should disable driver signature enforcement first then you can install it like in widows 7 https learn sparkfun com tutorials disabling driver signature on windows 8 disabling signe d driver enforcement on windows 8 How to disable driver signature enforcement Please follow next steps l Hold down the Windows key on your keyboard and press the letter C to open the Charm menu then click the gear icon Settings Page 20 of 61 ORFC Software User Manual A Click More PC Settings Change PC settings 3 Click General 4 Under Advanced Startup click Restart Now Page 21 of 61 ORFC Software User Manual P E Se tti a Q S Available storage You have 398 GB available See how much space your apps are US Personalize Users Refresh your PC without affecting you Notifications It your PC isn t running well you can refresh it without losing your videos and other personal files Search Get started Share Remove everything and reinstall Winc General if you want fo recycle your PC or start over completely you can re settings Privacy 5 Get started Devices Advanced startup Wireless Start up from a device or disc such as a USB drive or OWH chant firmware settings change Windows startup settings or restore Wi Ease of Access sync your settings UWaArmafcoraii
16. User Manual FUSSEN F100 ORFC Software V2 0 Version 1 0 LE on About this Manual P N 11 54 0008 Release Date July 2013 Copyright Fussen Technology Co Ltd 2013 All rights reserved Authorized Representatives Well Kang Limited Statement The User Guide for F100 includes information on the devices as well as their usage We recommend that you thoroughly familiarize yourself with this Guide in order to make the most effective use of your system User s operation failing to comply with this manual may result in malfunction or accident for which Fussen Technology Co Ltd hereinafter called Fussen can not be held liable Fussen owns the copyrights of this manual Without prior written consent of Fussen any materials contained in this manual shall not be photocopied reproduced or translated into other languages Materials protected by the copyright law including but not limited to confidential information such as technical information and patent information are contained in this manual the user shall not disclose such information to any irrelevant third party The user shall understand that nothing in this manual grants him expressly or implicitly any right or license to use any of the intellectual properties of Fussen Fussen holds the rights to modify update and ultimately explain this manual Responsibility of the Manufacturer Fussen only considers itself responsible for any effect on safety reliabil
17. age 51 of 61 ORFC Software User Manual koala server 192 168 1 185 2013 Manual Private protoc v When archiving PACS server in this configuration parameters are stored on DICOM Select knowledge which can refer to DICOM standard Device Name PACS server DICOM AF Title IP Address PACS server IP 0 lt Default gt Manual Standard Dico Port number PACS server service port number Syntax DICOM transfer syntax is stored Send Mode After collecting images click Save Dicom whether automatic archiving eliminating the need to manually archive each Protocol Communication protocol including Private protocol and Stand Dicom The system can be configured 2 Dicom storage servers simultaneously and only 1 private protocol storage Remote configuration Page 52 of 61 ORFC Software User Manual AET101 192 168 1 164 3011 AET164 192 168 1 164 3012 GB18030 v GB18030 Enable Enable When you need to connect a remote console or dicom query receive SCP you need to configure dicom query receive parameters on dicom query receive relevant knowledge which can refer to dicom standard Dicom Store SCU the unit as a Query Receive client related parameters Device Name The machine in Q R in the name IP Address This machine IP Port number The machine Q R communications port number Parameters Remote Query Receive service side Dicom Q R SCP Name remote Q R SCP The d
18. asks you would like Setup to perform while installing ORFC then dick Next Additional icons Create a Quick Launch icon 2 6 Ready to install and then click Install 7 a Setup ORFC Ready to Install Setup is now ready to begin installing ORFC on your computer Click Install to continue with the installation or dick Back if you want to review or change any settings Destination location DB Fussen ORFC Start Menu folder Fussen ORFC Create a desktop icon 27 Installing the DTFC Page 9 of 61 ORFC Software User Manual r aiia Setup ORFC Please wait while Setup installs GRFC on your computer D Fussen VORFCVYORFC exe i 2 8 At the end of Installation of DTFC the sensor driver will be installed 2 8 1 Choose setup language and then click OK r Setup ORFC ja x Installing Please wait while Setup installs ORFC on your computer Cancel 2 8 2 Welcome page and then click Next gt Page 10 of 61 ORFC Software User Manual iB Setup Fussen Sensor Driver EE Welcome to the Fussen Sensor Driver Setup Wizard This will install Fussen Sensor Driver version 1 2 0 10n your computer It is recommended that you dose all other applications before Click Next to continue or Cancel to exit Setup 2 8 3 Select destination location and then click Next gt ie Setup Fussen Sensor Driver CS Where should Fussen Senso
19. ay decline The following detailed description of each step Step One Open the UPS The uninterruptible power supply switch key to on state turn on the power supply to the computer console After the power is turned on need to wait for a minute or two before the second step Step two Open the high voltage generator Typically the high voltage generator will electrify the other components of the electrical system of the X ray Press the control cabinet key to open the high voltage generator NOTE The high voltage generator power on approach with specific hardware related WARNING Take improper precautions or not strictly follow the practices of the X ray system will cause harm to the patient and operator Third step Open the Control Panel Host Description Before you turn on the console make sure the detector is fully activated high voltage generator is turned on First open the monitor s power switch Then press the button to power on the host display starts with the host operating system to start a series of related information A few minutes later the host to complete the boot process Page 26 of 61 ORFC Software User Manual When the operating system starts the login window is displayed Enter the correct interface on the system to access including username and password Step Four login Console software Start Console software this software system can also be set to start automatically and login dialog w
20. by clicking button gt lt gt gt lt lt and other buttons to configure the patient information Meanwhile in the list alignment can select Align left Align middle Align right etc and click Up and Down button to sort After configuration is complete click OK button to confirm or the Cancel button to abandon configuration Refresh the work list heal button to refresh the list in order to obtain real time information of patients who have been registered but no examination Note Work list can be automatically refreshed according to the setting on the automatic setting please refer to the system management section Search a patient in the work list The management interface provides a series of search function by modifying related parameters in the query field and hel button to refresh the display list The search conditions include patient registration time patient ID and name Page 33 of 61 ORFC Software User Manual Registration time can be quickly selected by the buttons including today two days three days week and Custom time range NOTE If the patient ID and name is blank said any condition Deleting a record in work list Select a record in work list click the gt to delete and then a confirmation dialog will pops up Cancel Start study Select a patient in the work list double click the or click the then enter the acquisition and control
21. device to this computer f your device came with instructions please read them first Driver Name w FTDICDM Driver Packa w FUSSEN FUSSEN Dent 2 8 11 Completing page and the click Finish i Setup Fussen Sensor Driver Completing the Fussen Sensor Driver Setup Wizard Setup has finished installing Fussen Sensor Driver on your computer The application may be launched by selecting the installed icons Click Finish to exit Setup 2 9 Completing page and the click Finish Page 15 of 61 ORFC Software User Manual fe ia Setup ORFC jee Completing the ORFC Setup Wizard Setup has finished installing ORFC on your computer The application may be launched by selecting the installed icons Click Finish to exit Setup 5 Install the driver by manual If the sensor driver install unsuccessfully then a manual installation should be needed How to install the sensor driver by manually Please follow next steps 1 Press the key win and the key R at the same time Run dialog will show up _e ype the name of a program folder document or Internet Fre f resource and Windows will open it for you Open 2 Input devmgmt msc and then press key Enter or click OK Then the device manager window will show up Page 16 of 61 ORFC Software User Manual Device Manager File Action View Help e Bol 8 Er Fantasy Ting b Ee Batteries 4
22. e Filter type Dynamic Range The dynamic range of the output image Enhancement factor the high frequency part of the enhancement factor USM Equalizer coefficients USM low frequency part of equalizer coefficients Levels of detail multi scale enhancement layers Detail Enhancement multiscale enhancement factor Filter Type multi scale enhancement filtering type Picasso parameters Method Picasso 0 68 Thin edge 0 8 Medium edge Thick edge Noise of global Noise of Bright Gamma Contrast parameter about the contrast of the enhance image Thin edge parameter about the enhancement of thin edge Medium edge parameter about the enhancement of medium edge Thick edge parameter about the enhancement of thick edge Page 58 of 61 ORFC Software User Manual Noise of global parameter about suppression of global noise Noise of bright parameter about suppression of noise in bright area Gamma parameter about gamma transform 3 gt Orientation Orientation Rotation Rotate rotate the image after processing Flip Whether flipped upside down left or right flip images after processing 11 3 User Management Click management button to manage user information UserID User name admin Yan Yan g Administrator E LLL Add Normal Study Update System Delete Generator Process Delete Update A user with administrator permissions may carry on the management to other users including user
23. e Patient sex Patient size Patient weight Patient birthday Exam number Page 54 of 61 ORFC Software User Manual Series number Image number Manufacturer Modality Accession Number StudyInstance UID SeriesInstance UID SOPInstance UID Acquisition date Acquisition time Diagnoses Description Study Description Series Description Referrings Physicians Name Performing Physicians Name Read Study Physicians Name IO information ROI W L Default W L Flip vertica Flip horizonta Image hint Gray pseudo color ROI Magnifier Point grey value Adjust Zoom in Zoom out Real size WW WL Clip too Invalid Zoom Move Delete image Histogram W L Fit size Inverse Text labels Distance measure Angle measure Delete too Rotate 90 Restore Advanced process Up Down Pagination Tools in toolbar can be configured in this page the buttons selected will show on the left in image view page Page 55 of 61 ORFC Software User Manual Click button Up or Down to adjust index of the chosen button Show style of the selected tool buttons have two kinds pagination and show all Server Setting Q R Server enabled DICOM Q R SCP Client parameter IPAddr 127 0 0 1 AETitle IPAddr Port 2012 Time out 60000 ms BufferSize 32768 Update Initial count gt AETitle AET127 Lifetime 60 min IPAddr 127 001 Delete Port 3011 Process mode Thread mode Auto start When you need this console as a
24. e please expose press the high pressure remote control to produce X rays whenX rays received the sensor will generate an image and pass to the console PKO I Ready to Jui ii pi If you need to modify the sensor parameters click EA button to display the parameter settings and restart the sensor driven Click Button to hidden parameter settings and restart the sensor driven Page 47 of 61 ORFC Software User Manual Sensor Restart Options If the sensor driver failed to load you can restart the drive here or modify the settings in this reboot Information of restart process will be displayed at the bottom teeth template After sensor parameter setting click OK button and then restart the driver Be sure to hide the column after restart FUSSEN2D Cancel 11 System Management This section describes the system configuration management and related control functions System main menu provides system control and management functions in addition to the inspection process Including e System Management e check management e User Management e Password Management NOTE Different user permissions have different system management operations Administrator level users can perform system management functions of all the permissions while granted user depending on their privileges level Management from the status bar button to enter management options Page 48 of 61 ORFC Software User Manual 11
25. e will automatically clean up Minimum space When the system detects the storage space is less than this threshold then began to organize hard disk space delete the earlier inspection information log level The level of detail of the recording process detail level followed by normal mode common mode a detailed model and full model Other Language Support switch between Chinese and English Type The default check type IO Character Set Character set in the machine has been used Virtual Keyboard Enable do not enable the virtual keyboard Notation Tooth notation including FDI Universal Both Work List Page 50 of 61 ORFC Software User Manual koala server 192 168 1 185 2013 Select Do not refresh GB18030 Private protocol When RIS through Work list service requires registration and Work list server in this configuration parameters refer to the relevant knowledge about Work list Dicom standard Device Name Work list Server DICOM AETitle IP Address Worklist server IP Port number Worklist Server service port number Check the type whether the type of filter inspection Device Name whether AETitle consistency identified Auto Refresh whether Worklist refresh automatically eliminating the need to manually refresh each time Character Set WorkList server character set Protocol Communication protocol including Private protocol and Stand Dicom Storage Configuration P
26. e acquisition please refer to the image capture step acquisition operations 3 gt Quick Query All patients registered on the RIS and local registration if not checked will be listed R A 2 x in the to be inspected so you can choose to modify the NAA al and SA to start checking and other operations Query patients patient registered locally and RIS could be index query you can enter the patient ID or patient name oe gt unon to query patient data that belongs to a certain time period Page 29 of 61 ORFC Software User Manual The system supports precise and fuzzy query When exact query enter the full standard patient number or name in the query text box and press the Enter key or you can find all patient information belongs to a time period 7 3 Capture images v There are three ways to enter the image acquisition interface click button in D the to be checked interface click button in the registration interface and click we ae in the have been checked interface For patients who have previously checked click in the have been checked interface to enter the image acquisition interface no need to register patient information wv Select the patient from the to be checked interface click the A on to enter image acquisition interface as shown FLH T Right Left AARTI pene I Select teeth template and the desired shooting teeth Page 30 of 61 ORFC Softwa
27. e button to achieve the layout switching In non 1x1 layout you can double click on the image to maximize double click again to restore 3x 3Layout Hidden teeth template Click Ea button to hide and display tooth template part page turning If the images cannot be showed in a page layout you cal Previous nok Next to turn the page Save image as BMP JPG cc button to save the image which supports BMP JPG Page 42 of 61 ORFC Software User Manual E TestCon TestCon bmp Save the current image MA the button to save current image The end of view Click button to return to the studying list Save Changes cc button to complete image save and record refresh and return to study list Toolbar Toolbar buttons can operate and manage the image the the current image DM transfer window press the left mouse button to convert into ROI window width and position adjustment functions The default window width Window width click to pop up window width interface Page 43 of 61 ORFC Software User Manual Adaptive size NIO Text annotation click the left mouse button to convert text annotation capabilities FIN 90 degrees clockwise Upside down Flip around KJ Reduction i Angle Measurement Linear measurement Ld a Delete the current tools including labeling angle distance cutting boxes etc s m ae IShow or
28. e diagnostic imaging data Patient management to be checked registration have been checked mainly for patient information management Check film tooth marks mainly for photographic examination Image View processing display layout tools mainly for image viewing and processing Remote List View the remote client has checked the patient s image mainly for browsing remote terminal patient images Configuration system management inspection management user management password changes mainly for system configuration Software features 1 2 1 2 3 4 5 6 T 8 1 2 3 4 case management Case management functions including patient information check information and image management DICOM3 0 standard Work list inquiry service available from HIS PACS clinical data query and download image acquisition digital photography functions sensor configuration parameters Restart sensor driven Real time automatic window width and position adjustment real edge enhancement Select the mirror and rotate depending on the placement to display patient information check information device information image information The number of images that can be stored in the system in real time tips image processing window width and position adjustment positive and negative film conversion image scaling translation mirroring rotation magnifying glass display to select a region of interest
29. e number 7 on your keyboard Startup Settings Press a number to choose from the options below Use number keys or unctions keys F1 F9 1 Enable debugging 2 Enable boot logging 3 Enable low resolution video 4 Enable Safe Mode 5 Enable Sate Mode with Networking 6 Enable Safe Mode with Command Prompt 7 Disable driver signature enforcement 8 Disable early launch anti malware protection 9 Disable automatic restart after failure Press F10 for more options Press Enter to return to your operating system Your computer will restart automatically 10 After restarting you will be able to install the Arduino drivers normally however Windows will display a warning message When the warning appears click Install this driver software anyway If you are unfamiliar with installing Arduino drivers check out ourInstalling Arduino tutorial for a step by step guide Page 24 of 61 ORFC Software User Manual amp Windows can t verify the publisher of this driver software Don t install this driver software You should check your manufacturer s website for updated driver software for your device Install this driver software anyway mr Only install driwer software obtained from your manufacturer s website or disc Unsigned software from other sources may harm your computer or steal information See details Note The next time you restart your computer driver signature enforcement will be in effect again You
30. ent tooth modifications marked changes modification of patient information and replacement AT EET apoia b mali ulasa S Update information Page 40 of 61 ORFC Software User Manual button to update patient s information Update Replace DX000172 DxX000172 TestCon Cancel Male 2014 03 10 If you need to replace the study switch to the Replace page select a record in study list to replace Update Replace PatientID Name Gender Modality Accession Apply ti G13090606 lt 3 Female DX000146 _ 2013 09 Teeth Review G13090503 G13090501 G13090501 DX000008 DX000005 DX000005 DX000013 DX000011 DX000012 DX000131 DX000131 DX000014 DX000015 DX000018 DX000019 DX000020 DX000023 AER ABI ABE Fit 847 FRE FRK BT HEE SI HEE 28778 et Female Male MENE Other Other Other Other Other Other Other Other Other Other Other Other Other Other DX000143 DX000141 DX000141 28811605452 28811605945 28811604027 28811604864 28811605772 28811602722 DX000131 DX000131 28811606899 28811605774 28811606570 28811605484 28811606360 28811604570 2013 09 2013 09 2013 09 Cancel Select the image and then select the desired tooth marks in the template Layout Review Page 41 of 61 ORFC Software User Manual Click 2 to enter selection window move the mouse to select the desired layout and press the left mous
31. ent interface click the study list to enter the list where patients have been checked 2 E Name v est Custom 2012 12 30 PatientID PatientID Name Accession Study time Modality Body part Image count Archive 1 0x000172 DX000172 2014 03 10 20 29 05 10 DX 1 XOOI r a amp Bx List information The list includes information of patients who have been examined patient number name sex age height weight date of birth check number working position description number of images the archive identification marking etc All information can be configured to display by clicking EZ button to configure If the currently selected patient list as shown Page 36 of 61 ORFC Software User Manual Selected field Gender PatientID Age Name Height Weight Cancel Birthday Up Down Align center If the currently selected study list as shown Selected field Gender PatientID Age Name Height Accession Weight Study time Cancel Birthday Modality Description Body part Diagnoses Image count Up Archive Doctor name Down Align center In the configuration dialog you can add optional patient information in optional fields column to selected column which stands for current patient information by clicking button gt lt gt gt lt lt and other buttons to configure the patient information Meanwhile in the list alignment can select Align left Align middle Ali
32. evice name IP Address Remote Q R SCP s IP Port Remote Q R SCP port number Character set remote Q R SCP character set Enable Enable do not enable the connection The system can also configure two Dicom Q R SCP IO information Page 53 of 61 ORFC Software User Manual Parallel with prior AES left corner ight corner Patient age Fs gt See Hospital name Body Part Examined Patient size ee Patient name Patient weight Er Ad 3 Patient ID Patient birthDay Exam number Series number Image number Manufacture Modality a aa ein Bate Lower left corner Lower right corner SeriesinstanceUID H COPInctanrel ID vr n SOPinstanceUID StudylnstanceUID Study time Series date Study date Series time Kunder hss Up Acquisition date Acquisition time Diagnoses Description Down Study Description Series Description IO information for the four corners of the image display overlay information related to the display configuration Choose one corner such as the upper left corner and then select the comment was never configured to display the information click the Add button to add to the angular position or select from the angle configuration information click remove button to remove Information also can be moved up and down each corner location The information displayed can be configured by the Hospital name Patient name Patient ID Patient age Body Part Examined Study date Study time Series date Series tim
33. gn right etc and click Up and Down button to sort After configuration is complete click OK button to confirm or the Cancel button to abandon configuration Search a patient in study list The management interface provides a series of search function by modifying related parameters in the query field and clic button to refresh the display list The search conditions include patient registration time patient ID and name Registration time can be quickly selected by the buttons including today two Page 37 of 61 ORFC Software User Manual days three days week and Custom time range NOTE If the patient ID and name is blank said any condition Delete study patient Select one patient in the study list and click h l button delete confirmation dialog box pops up Cancel If you confirm the deletion click OK or Cancel Browse images In the study list select a patient double click or sog e button to enter the image browser interface Supplementary examination i l et If the patient is on the study list click A button to enter the image acquisition interface without the need to register Image Review If you need to modify the images like window width position and teeth markings click button to enter the image browsing interface Picture Archiving If you need to archive images click a button to select the specified server and click on the send button
34. ill pop up as shown admin Cancel Only one factory default user admin user password both admin After a successful login the console software s main screen appears as shown FUSSEN Work list PatientID Custon 2011 03 05 PatientID Gender Modality Age Accession Apply time Doctor name 05032510 Female 10 2 032510 2011 05 Page 27 of 61 ORFC Software User Manual Description When you enter a password the system does not display the associated character information Note The password is case sensitive If you need to change your password please refer to the system management settings 7 2 Patient Registration After the system login is successful enter the main interface of system Before making image acquisition image must be determined corresponding to the patient and examination information In the registration window check the list of information can be derived from the local registration or RIS registry 1 gt Local Registration There are three entrance into the registration screen the registration page tab check ye and have been the lower left corner of the page until the bottom left corner A p Aam a checked page Patient registration window as follows In the patient registration interface corresponding column entry of patient information including checking number patient number name height weight age gender type of examination the doctor s name date of bi
35. interface Update the patient information In the lower left corner of working list clic button to enter information modification interface Page 34 of 61 ORFC Software User Manual Update 032510 05032510 ipspw Cancel Female 1 793 2 2011 05 03 After modification click on the OK button to save your changes or click the Cancel button to exit 8 2 Registration Register ae f Click button or be button to enter registration interface In the patient registration interface you can entry of patient information including date checking number patient number name sex age height weight birth doctor s name diagnostic instructions and other information After insertion of the birthday the system will automatically calculate and display the age Page 35 of 61 ORFC Software User Manual Description Fields marked with are required to ensure that the patient s name and ID number you entered are correct Incorrect input will lead to duplicate entry or increase difficulties in the future work After the entry of patient information above if you find a typographical error you can modify or delete all the information by clicking 2 After confirming entry information is accurate cl Start button to enter image acquisition interface to start image acquisition please refer to 4 3 image capture steps 8 3 Study list Study list is similar with working list In the managem
36. ity and performance of the equipment if Assembly operations extensions re adjustments modifications or repairs are carried out by persons authorized by Fussen and The electrical installation of the relevant room complies with national standards and The instrument is used in accordance with the instructions for use Upon request Fussen may provide with compensation necessary circuit diagrams and other information to help qualified technician to maintain and repair some parts which Fussen may define as user serviceable Terms Used in this Manual This guide is designed to give key concepts on safety precautions WARNING A WARNING label advises against certain actions or situations that could result in personal injury or death CAUTION A CAUTION label advises against actions or situations that could damage equipment produce inaccurate data or invalidate a procedure NOTE A NOTE provides useful information regarding a function or a procedure Table of Contents TALLY SAIC ACS ee 1 Pe TAOS EEE 1 1 2 Warnings TTS 1 TZ ety NN 2 A NENNE 2 1 3 List Of SYMDOIS c eee cccssecessseecesseeeeeeeeeseeeessseecssseeessseecseaeecessueeseasessesseseseeeeseeeeeeas 3 2 FADOUT TAGS MINUA aeecasseccinasaecsvaannsauseocpoctase lt pasantanteneeaseqbeaanactecdsasnpaecanerpeaqeeaneiqurancioonsaectenannanbacteaenes 4 2 1 ASPICalon OF 16 MANUAlusasanas eesamassantmnmskennemsak dsu sad eses een 4 22 FE NE R EA EA 4 2
37. n NOTE In Windows 8 1 the Restart Now button has moved to PC Setting gt Update amp Recovery gt Recovery After restarting click Troubleshoot Choose an option Continue Troubleshoot advanced tools Use another operating z S 3 1 4 Click Advanced Options Page 22 of 61 ORFC Software User Manual 101012901010 P rs K Ta Refresh your PC If your PC isn t running well you can refresh it without losing your files Reset your PC lf you want to remove all of your files you can reset your PC completely Advanced options Click Windows Startup Settings System Restore Command Prompt Use a restore point recorded on your EE zE Use the Command Prompt for PC to restore Windows GN advanced troubleshooting System Image Startup Settings Recovery ag i _ Change Windows startup behavior Recover Windows using a specific system image fle Automatic Repair Fix problems that keep Windows from loading Click Restart Page 23 of 61 ORFC Software User Manual Windows Startup Settings Restart to change Windows options such as Disable driver signature enforcement Deable carby launch anti malware protection Deable automatic restart on system failure Enabee low resolution video mode Enable detugging mode Enaber boot logging Enab e Safe Node 9 After restarting your computer a second time choose Disable driver signature enforcement from the list by typing th
38. ndicates that the device complies with the European Council Directive 93 42 EEC concerning medical devices Authorized Representative in the European Community The symbol indicates that the device should be sent to the special agencies according to local regulations for separate collection after its useful life Page 3 of 62 ORFC Software User Manual 2 About the Manual 2 1 Application of the Manual The manual mainly introduces functions of the ORFC Software and the way to operate it Before the use of this software please read the manual of the devices that connected to this software carefully This manual is designed for the clinics that using ORFC Software It provides work flow of a patient study Mostly it ll introduce the operation steps system structure and features Attention there s no guideline and assistant for clinic diagnosis 2 2 Applicable Object The manual is applicable to clinical professionals and other authorized users 2 3 Legend and Name All legends provided in the manual are just for examples All names shown in examples and legends are imaginary It is coincidence if somebody happens to have the same name with that in the manual Page 4 of 61 ORFC Software User Manual 3 Summary 3 1 System Feature Overview ORFC Software consists of several modules each of the different modules perform specific functions which enabling patients to check the process and provide an effectiv
39. o not switch on the power until all cables have been properly connected and verified 3 The user should get professional training and read this manual in detail before using the system 4 This system is not intended for treatment 5 Donot move the main unit or the monitor while working 6 Only accessories supplied or recommended by the manufacturer can be connected to the system 1 2 2 General Cautions CAUTION 1 Do not bend or press the CD 2 Keep the CD away from direct sunlight and high temperature Otherwise the CD may become deformed 3 Do not touch the disk surface of the recorded side If the surface becomes contaminated with any foreign substance such as fingerprints reading data may be impossible 4 Clean the CD with a disk cleaner Do not use organic solvents such as acetone 5 This CD ROM disk is not an audio CD and can not be played with an audio CD player 6 Avoid liquid splash and excessive temperature The temperature must be kept between 5 2C and 40 2C during operation 7 Do not use the system in a dusty environment with bad ventilation or in the presence of corrosive Avoid vibration 8 Do not handle the CD while smoking or eating 9 Do not get the CD wet Page 2 of 62 ORFC Software User Manual 1 3 List of Symbols AN Consult Instructions for Use Type BF Device The sensor is a Type BF device Part Number Serial Number Date of Manufacture Manufacturer The symbol i
40. of the original display full screen display histogram display window width and position adjustment image annotation features including orientation and text Page 5 of 61 ORFC Software User Manual e image output I DICOM3 0 standard archiving service the image archive to the server support background automatically sent 2 image backup the backup image to CD DVD the disc comes with a backup browser automatically play back images 3 image export you can export the patient examination to the specified location supporting DCM DCMDIR JPG and BMP supports standard formats and compression formats 3 2 Work conditions suggestion Environmental Conditions 1 gt Ambient temperature 5 C 40 C 2 gt Relative humidity lt 80 3 gt Atmospheric pressure 700hPa 1060hPa Supply conditions 1 gt Voltage AC 220V 22V 2 gt Frequency 50Hz 1Hz 3 gt resistance lt 0 39 4 gt Power not less than 0 6 1 10 kVA PC operation platform 1 gt CPU Intel central processor gt 2 0GHz 2 gt Memory gt 2G 3 gt Hard disk gt 500G according to the specific circumstances of storage space expansion 4 gt Display Resolution 1280X1024 aspect ratio 4 3 5 gt Operating System Window XP Window NT Win7 4 Installation Unzip the file Fussen ORFC Setup zip 2 Run the Fussen ORFC Setup3 3 0 1 exe A warning dialog will show if you run on windows 7 If that please choose yes 2 1 Choose
41. r Driver be installed D Setup will install Fussen Sensor Driver into the following folder To continue dick Next If you would like to select a different folder dick Browse At least 2 8 MB of free disk space is required 2 8 4 Select start menu folder and then click Next gt Page 11 of 61 ORFC Software User Manual if Setup Fussen Sensor Driver Select Start Menu Folder Where should Setup place the program s shortcuts i Setup will create the program s shortcuts in the following Start Menu folder To continue dick Next If you would like to select a different folder dick Browse ussen SensorDriver Don t create a Start Menu folder 2 8 5 Ready to install and then click Install Setup Fussen Sensor Driver z Ready to Install Setup is now ready to begin installing Fussen Sensor Driver on your computer Click Install to continue with the installation or dick Back if you want to review or change any settings Destination location D Fussen SensorDriver Start Menu folder 2 8 6 Installing the Fussen sersor driver Page 12 of 61 ORFC Software User Manual if Setup Fussen Sensor Driver iu ii 28 Please wait while Setup installs Fussen Sensor Driver on your computer Installing dirver please wait i L d 2 8 7 Welcome page of device driver install and then click Next gt Device Driver Installation Wizard Welcome to the Device
42. re User Manual Z ci collection button and wait for the status bar tips to exposure 3 Exposure press high pressure remote button and release after the first alarm which means x ray generation while a second time rang is on behalf of the end of the x ray If not ring twice check the pressure and the remote control 4 After exposure ends image display area right side will display the image you have just taken 5 To continue shooting repeat 1 3 6 il Save button to complete examination 7 4 Exit Exit Description When a study is capturing the user can not be cancelled unless close the capture In the console main interface if you want to change user logout current interface by clicking Exit button and then the user login window appears If you added a new user to log in you need to restart the console software Shut down the system Typically the constituent components of the system are maintained in working condition Console host monitor and detector will go to sleep state in order to save energy if not used within a period of time Recommended shutdown procedures I Turn off the console computer 2 Turn off the X ray generator In general the other components in the X ray system are turned off 3 Close the console of an uninterruptible power supply and the same time turn off the detector Note 1 Console host should shut down every day to ensure that the complete system reset process otherwise
43. rivers on my computer This list will show installed driver software compatible with the device and all driver software in the same category as the device If install the sensor driver on windows 7 a dialog about windows security will show up please choose Install this driver software anyway Page 18 of 61 ORFC Software User Manual Windows Security T x Windows can t verify the publisher of this driver software Don t install this driver software You should check your manufacturers website for updated driver software for your device gt Install this driver software anyway Only install driver software obtained from your manufacturer s website or disc Unsigned software from other sources may harm your computer or steal information vw See details 6 Completing page gt Update Driver Software FUSSEN USB Serial Converter A Windows has successtully updated your driver software Windows has finished installing the driver software for this device FUSSEN USB Serial Converter The hardware you installed will not work until you restart your computer 7 Choose another USB lt gt Serial Converter and do step 3 6 again 8 After install USB lt gt Serial Converter there are two USB Serial Port You should Choose them and do step 3 6 to install If successes there are two Dental X Ray Sensor Port COMXX in the Ports Com amp LPT and two FUSSE
44. rth diagnosis instructions check the description and other information you can press the Tab key the switch between After insertion of the birthday the system will automatically calculate and display the age Description Fields marked with are required to ensure that you enter the patient s name and ID number are correct and different patient ID numbers are different Incorrect input will lead to duplicate entry or increase difficulties in the future work of Page 28 of 61 ORFC Software User Manual the same patient After the entry of patient information above if you find a typographical error you can modify delete information can also PA C to clear information After confirming entry information is accurate stick tton then enter the check image acquisition interface to start image acquisition Please refer to the image capture step acquisition operations 2 gt RIS Register After properly setting up RIS work list services how to set up can refer to the System Management Work List section of the set the inspection window can be automatically or manually refresh RIS registered patient information and receive patient information over the network As shown below PatientID Custom 2011 03 05 v 2012 03 05 PatientIC ame Gender Modality Age ACCESSION Apply time Doctor name 1 l hit FLIN ic 1 i I cc Start button to enter the check image acquisition interface to HUKA ry S JE ti Ja start imag
45. s to add modify license rights and other control 11 4 Password Click the Password button to modify the password Page 59 of 61 ORFC Software User Manual Cancel 12 Maintenance You should be familiar with all the operation methods of this system Read this user manual in detail and don t use this system before understanding the whole operation process ORFC Software just needs simple maintenance during the operation process But only the right operation method can guarantee the system s long time and steady working So you must comply with the notice and maintenance presented by the manufacturer strictly Maintenance of the CD 1 Do not bend or press the CD 2 Clean the CD with a disk cleaner Do not use organic solvents such as acetone 3 Do not handle the CD while smoking or eating 4 Keep the CD away from direct sunlight and high temperature Otherwise the CD may become deformed 5 Do not get the CD wet Do not touch the disk surface of the recorded side If the surface becomes contaminated with any foreign substance such as fingerprints reading data may be impossible Page 60 of 61 ORFC Software User Manual 13 Warranty and Service 13 1 Warranty Fussen warrants that Fussen s products meet the labeled specifications of the products and are free from defects in materials and workmanship that occur within warranty period The warranty period begins on the date the products are shipped to