1. User manual version 1 English 36 SPIRO TECH 7 1 A BRWN 37 FOR BETTER PERFORMANCE FAILURES Remedy failures WARNING In case of failure always warn the installer Remove the voltage and pressure from the unit before starting the activities see 7 2 Pressing ON OFF does not remove the voltage from the unit WARNING There are hot parts below the cover Let the unit cool down before starting the activities NOTE In case of a failure the red LED is lit The failure report appears in the display NOTE With the types S10A R and S16A R the seriousness of the failure determines whether the whole unit or a part of the unit switches off With partly switching off the refilling process remains active In this case both the red and the green LEDs are lit Localise the failure using the failure table see 7 3 If necessary put the unit out of operation see 7 2 Remedy the failure Manually start the unit see 7 3 1 or put the into operation again see 5 5 4 7 2 u English SPIROVENT SUPERIOR Putting out of operation Take the plug out of the wall socket and switch off the main switch Make sure that switching on the voltage unintentionally is not possible Close the valves A and or C in the inlet line and B and or D in the outlet line Close if applicable the valve E in the refill supply line as we
2. Nature of the maintenance Inspection date Technician Initials Nature of the maintenance Inspection date Technician Initials Nature of the maintenance Inspection date Technician Initials Nature of the maintenance User manual version 1 English 42 SPIRO TECH 9 9 1 43 FOR BETTER PERFORMANCE GUARANTEE Terms of guarantee The guarantee for Spirotech products is valid until 2 years following the purchasing date The guarantee lapses in cases of faulty installation incompetent use and or non authorised personnel trying to make repairs Consequential damage is not covered by the guarantee English SPIROVENT SUPERIOR User manual version 1 SPIR TECH FOR BETTER PERFORMANCE SPIROVENT SUPERIOR 10 CE STATEMENT 10 1 Declaration of conformity SPIR TECH Declaration of Conformity ron IRK PERFORMANCE According to EN ISO IEC 17050 2004 Manufacturer Spirotech bv Address Churchilllaan 52 5705 BK Helmond The Netherlands Products SpiroVent Superior S10A S10A I S10A R S10A R I S16A S16A I S16A R S16A R I We declare entirely on our own responsibility that these products comply with the following standards EN 12100 1 EN 12100 2 EN 60204 1 EN 60335 1 EN 60730 1 EN 61000 3 2 EN 61000 3 3 EN 61000 6 2 EN 61000 6 3 In accordance with the stipulations of
3. Temperature refill fluid n a 0 70 C n a 0 70 C User manual version 1 English 28 SPIRO TECH FOR BETTER PERFORMANCE 3 5 Building Management System BMS The unit has been provided with auxiliary contacts fo r communication with a BMS The BMS must offer a 24 Vac SPIROVENT SUPERIOR voltage Signal S10A S10A R S16A S16A R Unit ready Potential free Potential free Potential free Potential free Unit failure Potential free Potential free Potential free Potential free Unit release stop 24 Vac 24 Vac 24 Vac 24 Vac Refill by BMS n a 24 Vac n a 24 Vac 4 SAFETY 4 2 Type plate WARNING A personnel Installation and maintenance of the unit should only be carried out by qualified Remove the voltage and pressure from the unit before starting the activities WARNING There are hot parts below the cover Let the A 4 1 CE marking The unit has a CE marking This means that the unit has been designed constructed and tested in compliance with the current safety and health regulations Provided that the user manual is adhered to the unit be safely used and maintained 29 unit cool down before starting the activities can zoarmonu gt SPIROVENT SUPERIOR Article No Type Power input ae Voltage Frequency IP class E Pressure PS Oo Temperature TS F Serial no Year of manufacture G Weight Spirotech bv The Netherl
4. Letter Description 15 552 Q Shaft sealing for pump type CR1 33 23 21 15 A FGJ A E HQQE 14 292 Q Gasket for pump type CR1 33 25 21 15 R17 883 Q Pump S10 CR1 21 A FGJ A E HQQE 50 Hz R17 938 Q Pump S16 CR1 33 A FGJ A E HQQE 50 Hz Request Q Pump S10 CR1 15 A FGJ A E HQQE 60 Hz Request Q Pump S16 CR1 23 A FGJ A E HQQE 60 Hz R17 733 U Cover 12 023 H Solenoid valve excluding coil 12 022 H Coil for solenoid valve 12 018 H Interior for solenoid valve 13 467 G Pressure gauge R17 889 Non return valve refill R17 886 C Automatic air vent R17 748 V Pressure switch press side 10 R18 047 V Pressure switch press side S16 13 468 P Pressure switch tank R18 091A01 S Control unit S10A R18 091A02 S Control unit S10A R R18 091A03 S Control unit S16A R18 091A04 S Control unit S16A R R17 888 R SmartSwitch R17 959 J Adjustment valve inlet 15 518 N Adjustment valve outlet 13 466 K Level switch 15 519 l Water flow meter S10A R and S16A R R18 077 O Pressure sensor S10A R en S16A R R70 149 M Flow back limiter 41 English User manual version 1 SPIR TECH FOR BETTER PERFOAMANGE SPIROVENT SUPERIOR 8 3 Maintenance card Type Serial number Installation date Installed by firm Installed by technician Inspection date Technician Initials Nature of the maintenance Inspection date Technician Initials Nature of the maintenance Inspection date Technician Initials
5. MENU Select User menu gt Manual operation using A and V Press ENTER 2 Select Manual operation start or Manual operation stop using A and V Press ENTER 5 5 3 Filling the installation Applies to types S10A R and S16A R NOTE The unit also fills the installation with degassed or not degassed fluid When the desired system pressure is reached the unit automatically goes to the standby status English 34 SPIRO TECH FOR BETTER PERFORMANCE SPIROVENT SUPERIOR 1 Press MENU Select User menu gt Manual 1 Press MENU Select User menu gt General data operation using A and V Press ENTER using A and V Press ENTER 2 Select Manual operation system filling 2 Select an item using A and VY Press ENTER using A and V Press ENTER 3 Repeatedly press EXIT to return to the status report 3 Select Degassed or Not degassed Press ENTER 6 USE 5 5 4 Switch on again Follow the procedure described below after the unit has been switched off 6 1 General 1 Set the adjustment valves from the position fully The display lighting automatically dims after no key open in accordance with the table in 5 4 1 has been pressed for 5 minutes Press a key to 2 Press ON OFF activate the lighting 3 Press ENTER two times The unit starts filling While stopping the process a stop procedure is 4 Wait for 20 seconds until Initial filling in started making sure that the unit stops in a safe progress disappears situa
6. Machine Directive 2006 42 EC Low Voltage Directive 2006 95 EEC EMC Directive 2004 108 EC Helmond validated June 9 2009 Date and place of preparation of the document Dr D Scholten Managing Director Full name position Declaration of Conformity Superior 10 16 version 1 June 2009 User manual version 1 English 44 SPIRO TECH FOR BETTER PERFORMANCE The manufacturer reserves the right to make changes without prior notification Copyright Spirotech bv Information given in this brochure may not be reproduced complete or in part without the prior written consent of Spirotech bv Spirotech bv The Netherlands www spirotech com
7. lines leave the unit at the rear CAUTION Preferably use a wall socket for the power supply to the unit This should always be accessible Mount an all pole main switch contact opening gt 3mm if the unit is directly connected to the power supply Use supply cables with the correct dimensions Always replace a defective fuse by a fuse of the same value See 3 3 Q o Ley O o 00 O Yo EE Feed a 5 core supply cable through swivel A and connect this to connector J16 User manual version 1 SPIR TECH FOR BETTER PERFORMANCE SPIROVENT SUPERIOR 2 If aBMS is used connect the BMS cable to connector J20 With the types S10A R and S16A R 1 If an external device checks the refill connect a cable to connector J21 5 4 Commissioning 5 4 1 Preparation 1 Close the valves E and F in the inlet and outlet lines 2 Set the adjustment valves A and B from the position fully open in accordance with the following table 3 Open the valve C behind the pressure gauge D 4 Open the valve G in the refill line S10A R S16A R System position adjustment valve pressure s10 S16 bar inlet outlet inlet outlet 5 to6 6 2 6 to7 3 4 2 7t0
8. outlet line T is closed Open the valve The outlet line has been obstructed Remove the obstruction The pump Q does not run Check the pump Check and replace the pump fuse in the control unit The automatic air vent C is blocked Replace the automatic air vent The pressure switch P is defective Replace the pressure switch Err 7 Fluid lack vessel There is a risk of running dry the fluid level in the vessel is at the minimum The automatic air vent C is defective or blocked Replace the automatic air vent The vessel has not been filled Fill the vessel see 5 5 4 The level switch K is defective Replace the level switch Cable to level pin disconnected or interrupted Check cable connection Replace cable Err 8 Pump is too hot Pump is overloaded Pump Q blocked does not run smoothly Remove the blocking Cooling is blocked Clear pump fan Err 9 Pump overloaded Pump overloaded too often Pump blocked does not run smoothly Remove the blocking Cooling is blocked Clear pump fan Err 18 outlet pressure is too high The flow in the outlet line is blocked A valve in the outlet is closed Open the valve The outlet line is blocked Remove the blocking Pressure switch V is defective Replace the pressure switch Err 17 Incorrect phase sequence Voltage was not connected correctly Phases
9. the installation pressure The refill process starts and stops automatically at the set values The unit can also be used to automatically fill the installation with degassed fluid 2 3 Operating conditions The unit is suitable for use in systems filled with clean water or mixtures of water with a maximum of 40 glycol Use in combination with other fluids may result in irreparable damage The unit should be used within the limits of the technical specifications as given in chapter 3 WARNING In case of doubt always contact the supplier In case of a heavily contaminated system fluid a dirt separator is to be installed in the main return line of the installation 2 4 Scope of delivery 1x Spirovent Superior 1x User manual 1x Non return protection optional SPIROVENT SUPERIOR 3 TECHNICAL SPECIFICATIONS 3 1 Dimensions 400 1272 Height mm 1272 Width mm Depth mm 744 400 27 English User manual version 1 SPIR TECH FOR BE ER PERFORMANCE SPIROVENT SUPERIOR 3 2 General specifications S10A S10A R S16A S16A R Max system volume 150 300 m 150 300 m 150 300 m 150 300 m Empty weight 77 kg 79 kg 90 kg 92 kg Volume of degassing vessel 8 8 8l 8l Inlet connection Swivel G a Bi Swivel G a Bi Swivel G a Bi Swivel G a Bi Outlet connection Swivel G a Bi Swivel G a Bi Swivel G a Bi Swivel G a Bi Drain connection
10. were connected in incorrect order Restore the correct phase sequence on connector J16 Err 99 Failure in the control unit Control hardware or software defective Replace the control unit User manual version 1 English 38 SPIRO TECH FOR BE ER PERFORMANCE SPIROVENT SUPERIOR Problem Possible cause Correction The unit runs continuously and does not switch off automatically The SmartSwitch does not seem to work The content of dissolved gases has not reached the minimum yet Check whether there is a possibility of gases entering The SmartSwitch R is defective Replace the SmartSwitch if the unit does not switch off after 10 minutes The air outlet has been blocked Check whether gas is released through the valve Replace the automatic air vent when no gas is released The unit runs maximally 10 min per degassing period Gases remain in the installation The SmartSwitch does not seem to work The SmartSwitch R is defective Check whether gas is released through the valve If gas is released replace the SmartSwitch If no gas is released replace the SmartSwitch The automatic air vent C is defective Replace the automatic air vent The refill mode remains active this applies to types S10A R and S16A R 39 English User manual version 1 SPIR TECH FOR BETTER PERFORMANCE Applies specifically to t
11. 18 338 00 SPIRO TECH FOR BETTER PERFORMANCE Gebruikershandleiding gt 03 User manual gt 21 SPIROVENT SUPERIOR S10 S16 SPIR TECH FOR BETTER PERFORMANCE TABLE OF CONTENTS Preface Introduction Technical specifications Safety Installation and commissioning Use Failures Maintenance 6 AN DH aA WN S Guarantee 10 CE statement All rights reserved No part of this manual may be 24 25 27 29 30 35 37 41 43 44 duplicated and or made public through the Internet by means of printing photocopying microfilm or in any other way without prior written permission from Spirotech bv This manual has been composed with the utmost care Should this manual contain any inaccuracies in spite of this Spirotech bv cannot be held responsible for these User manual version 1 SPIROVENT SUPERIOR 1 PREFACE This user manual involves the installation commissioning and operation of the Spirovent Superior of the types S10A S10A R S16A and S16A R Always carefully read the instructions before installation commissioning and operation Keep the instructions for future reference 1 1 Symbols Throughout the instructions the following symbols are used Warning or important note Advice Risk of electric shock Risk of burning gt gt 9e English 24 SPIR O TECH 2 2 1 FOR BETTER PERFORMANCE INTRODUCTION Overview of the unit SPIROVENT SUPERIO
12. 8 3 2 8t09 27 4 6 9 to 10 2 6 6 1 10 to 11 gt 3 1 connector contact connection 11 to 12 23 a 12 J20 1and2 Unit ready 12 to 13 23 4 11 3and4 Failure 13 to 14 z 22 11 5and6 On off 14 to 15 2 1 a 7and8 Refill 15 to 16 p 2a 1 J21 1 and 2 Refill applies to types S10A R and S16A R User manual version 1 English 32 SPIRO TECH FOR BETTER PERFORMANCE 5 4 2 Start up ON OFF SPIROVENT SUPERIOR Filling the unit A On off 1 B Display 2 C Status report in operation OK 3 D Up j E Confirm Enter 4 F Menu G Down 5 H Cancel Exit j Status report failure 6 CAUTION The start up routine starts automatically 7 when the unit is switched on for the first 8 time Press EXIT to go back one step in the 9 menu while programming Follow the procedures given below for entering the required parameters Set date en time 1 Press ON OFF 2 Select a language using A and V Press ENTER 3 Set the date using A and W Press ENTER 4 Set the day using A and V Press ENTER 5 Set the time using A and V Press ENTER 33 C English Open the valve E in the inlet Press ENTER two times The unit starts filling Wait for 20 seconds until Initial filling in progress disappears Loosen the air vent screw A a few turns and tighten it again when air has stopped coming out Repeat steps 1 3 until water starts coming out of the air ven
13. R Superior S1I0A S16A Superior S10A R S16A R m I A cc Arno nrmonu gt N 61 Inlet line Refill connection types S10A R and S16A R Automatic air vent Deaeration vessel Locking cap Valve behind pressure gauge Pressure gauge Solenoid valve Water flow meter Adjustment valve inlet Level switch in bottom of vessel lt ceHnvn a o vozzr English Drain connection Flow back limiter Adjustment valve outlet Pressure sensor S10A R S16A R Pressure switch tank Pump SmartSwitch Control unit Outlet line Cover Pressure switch press side S10A S16A User manual version 1 SPIR TECH FOR BETTER PERFORMANCE 2 2 Operation The figure below schematically shows the operation of the unit The letter indications comply with the main figure on the previous page SPIROVENT SUPERIOR NI Superior S10A R Superior SI6A R 2 2 1 General 1 The Superior is a fully automatic vacuum degasser for installations filled with fluid The fluid contains dissolved and undissolved gases The function of the unit is to remove these gases from the installation until the concentration of undissolved gases has reached an absolute minimum P
14. Swivel G Bu Swivel G3 4 Bu Swivel G Bu Swivel G34 Bu Noise level Approx 57 dB A Approx 57 dB A Approx 57 dB A Approx 57 dB A Refill connection n a Swivel G3 4 Bi n a Swivel G3 4 Bi 3 3 Electrical specifications S10A S10A R S16A S16A R Supply voltage 3x400V 10 3x400V 10 3x400V 10 3x400V 10 Absorbed power 50 Hz 60 Hz upon request 1150 W 50 Hz 60 Hz upon request 1150 W 50 Hz 60 Hz upon request 2250 W 50 Hz 60 Hz upon request 2250 W Nominal power consumption 1 9 1 9 3 0 3 0 Protection 10 A 3 15 A T 10 A 3 15 A T 10 A 3 15 A T 10 A 3 15 A T Protection class IP X 4D IP X 4D IP X 4D IP X 4D Max load of potential free 24V 1A 24V 1A 24V 1A 24V 1A contacts Supply voltage for BMS 24 Vac 24 Vac 24 Vac 24 Vac control voltage of BMS Supply voltage of external n a 5 Vdc n a 5 Vdc refill signal supplied voltage 3 4 Other specifications S10A S10A R S16A S16A R System pressure 5 10 bar 5 10 bar 9 16 bar 9 16 bar Ambient temperature 0 40 C 0 40 C 0 40 C 0 40 C Maximum compression 16 bar 16 bar 25 bar 25 bar pressure with closed valve behind pressure gauge Refill flow n a See graph in 6 1 n a See graph in 6 1 System fluid temperature 0 90 C 0 90 C 0 90 C 0 90 C Refill pressure n a 0 10 bar n a 0 10 bar
15. ably install the unit at the point in the installation with the lowest temperature Here the most dissolved gases are found in the fluid Make sure when installing that the operating panel is always easily accessible 5 3 1 Mounting Place the unit on a flat surface against a flat closed wall Mount the unit on the floor using the holes A English 30 SPIRO TECH SPIROVENT SUPERIOR FOR BETTER PERFORMANCE 5 3 2 Installation 2 Connect the supply line to the refill connection G Mechanical of the unit CAUTION Electrical 1 Make two branch lines A on the side of the main transport line The distance between them should be at least 500 mm 2 Insert a valve B in each branch With this the unit can be depressurised tr lt B Hr NOTE As seen from the direction of the volume flow the first branch is the inlet into the unit P 3 Connect the line A to the flexible outlet line D 1 4 Connect the line B to the flexible inlet line C With the types S10A R and S16A R 1 Insert a valve F and a non return protection E in the refill fluid supply line 31 English Use a locally approved non return protection A non return protection can be optionally delivered Make sure that the pressure in the water lines is below the system pressure This prevents undesired refilling in case of failure of the refill line Make sure that the
16. ands Type of the unit Absorbed power Supply voltage Protection class System pressure System temperature Serial number Year of construction Weight ce X AR A A The type plate has been applied on the inside of the unit Remove the cover to read the data on the type plate English User manual version 1 SPIR TECH FOR BETTER PERFORMANCE 5 INSTALLATION AND COMMISSIONING 5 1 Installation conditions Install the unit on a frost free well ventilated place Electrically connect the unit to a 3 x 400 V 50 Hz socket 60 Hz upon request Make sure the expansion system has the correct dimensions The water displacement in the unit can cause pressure variations in the installation Take into account an extra net expansion volume of min 8 litres There must be overpressure in the installation This prevents spontaneous deaeration 5 2 Unpack The unit is delivered on a wooden pallet 1 Remove the packaging 2 Loosen the bolts A 3 Move the unit to the place where it is to be installed Lift the unit by means of the lifting hooks C User manual version 1 SPIROVENT SUPERIOR 5 3 Installation and mounting CAUTION A Install the unit in accordance with the local guidelines and rules Install the unit as bypass on the main transport line of the installation Preferably install the unit as close as possible to the expansion system EF NOTE Prefer
17. ed days are marked with an After having changed this parameter select Store using A or V Press ENTER Block time year 1 Period per year during which the unit is not working Block time year 2 5 See Block time year 1 Max syst pressure Pressure at which the unit stops Psystem desired Pressure at which the refilling stops Set this as low as possible if the refilling is checked by the BMS or external devices Refill on at Pressure at which the refilling starts Set this as low as possible if the refilling is checked by the BMS or external devices Refill alarm Maximum amount of fluid that may be refilled per time 0 2500 l 0 switched off Refill alarm after Continuous refilling time 0 255 min 0 switched off Parameter Description Language Language for the display texts Date The current date Weekday The current weekday Time The current time Auto start 1 Time 1 for starting the degassing process Auto start 2 See Auto start 1 Block time day 1 Time for stopping the degassing process User manual version 1 Max refill freq Maximum number of times per day that refilling is allowed 0 10 times 0 switched off applies to types S10A R and S16A R 5 5 2 NOTE C Manual operation If manually switched off the process must be manually switched on again 1 Press
18. gh Refilling takes place too frequently There is a leak in the installation Repair the leak Check the setting Max refill freq Err 14 Refill too long Refilling takes too long There is a leak in the installation Repair the leak Check the setting Alarm refill after Err 15 Refill quantity Too much is added There is a leak in the installation Repair the leak Check the settings Refill alarm The status is degassing but the system pressure continues to increase Inlet system and refilling are switched Make sure the connections are correct Pressure indicated on display deviates strongly from actual system pressure Pressure sensor O is blocked or defective Replace the sensor The refill mode remains active this applies to types S10A R and S16A R 7 3 1 Resetting the unit 1 Press MENU Select User menu gt Manual operation using A and V Press ENTER 2 Select Manual operation reset using A and V Press ENTER User manual version 1 English 40 SPIRO TECH FOR BETTER PERFORMANCE SPIROVENT SUPERIOR 8 MAINTENANCE 2 Replace the automatic air vent every two years 8 1 Periodic maintenance 1 Annually replace the interior of the solenoid valves H 8 2 Replacement parts The letter indications comply with the main figure in 2 1 Article number
19. ll Connect a drain line H to the drain connection G Drain the unit through the drain connection G Open the air vent screw on the main pump O to completely empty the unit See the figure in 5 4 2 User manual version 1 SPIR TECH FOR BETTER 7 3 Failure table General PERFORMANCE The letter indications comply with the main figure in 2 1 An overview of the replacement parts has been included in 8 2 SPIROVENT SUPERIOR Problem Possible cause Correction Err 5 Inlet flow The flow in the inlet line has been blocked The solenoid valve H in the inlet line does not open Replace a part of the solenoid valve A valve in the inlet line A is closed Open the valve The inlet line has been blocked Remove the blocking The pressure switch P is defective Replace the pressure switch Critical setting adjustment valve inlet J Turn adjustment valve 1 4 position up from fully open Cable to pressure switch P disconnected or interrupted Replace cable Replace cable lugs The adjustment valve N inlet has not been set correctly Turn the adjustment valve outlet to the correct position see 5 4 1 Err 6 Flow The flow in the outlet line has been blocked Solenoid valve H in the inlet line A does not close Clean valve internally If necessary replace a part of the solenoid valve The valve in the
20. roblems caused by gases in the 2 installation are thus eliminated The types S10A R and S16A R have an integrated refill automat The refill automat maintains continuous pressure in the installation For this the unit adds degassed fluid if necessary The unit can also fill the entire installation with degassed fluid 2 2 2 Degassing The unit starts up daily with the degassing process at a time indicated by the user The process comprises two phases User manual version 1 English The rinsing phase The fluid flows from the installation through the solenoid valve H into the vessel D The pump Q continuously pumps the degassed fluid from the vessel into the installation Here the degassed fluid absorbs gases again The vacuum phase The solenoid valve H regularly closes starting the vacuum phase The continuously running pump Q provides underpressure in the vessel D The underpressure causes the release of the gases dissolved in the fluid which are collected at the top of the vessel The solenoid valve H opens again starting a new rinsing phase The gases collected in the vessel are removed from the installation through the automatic air vent C The SmartSwitch R in the control unit ensures that the degassing is stopped as soon as the content of dissolved gases has reached the minimum level 26 SPIRO TECH FOR BETTER PERFORMANCE 2 2 3 Re fill The types S10A R and S16A R of the unit constantly check
21. sing A and V Press ENTER 3 Select an item using A and VW Press ENTER A System pressure water pipe pressure bar 4 Repeatedly press EXIT to return to the status report B Flow I hour 5 5 6 Reading data The following general data have been stored in the memory of the unit Unit type Software version Installation date Trial period arranged by agent The general data can be read in the following way 35 English User manual version 1 SPIR TECH FOR BETTER 9 14 bar PERFORMANCE S16 14 16 bar 0123 45 6 7 8 9 101112131415 16 A gt SPIROVENT SUPERIOR 6 2 Status reports Report Description LED indication Auto pump test The unit runs a pump test Green End of degassing The stop procedure is in progress Green End of refilling End of filling the system Degassing The degassing process is in progress Green Process stopped The unit has been stopped manually None Standby The unit is waiting for a starting signal Green Stop by BMS The BMS has stopped the unit After release by the BMS the unit None must be started manually Failure The unit has stopped because of a failure Remedy the failure before Red resetting the unit see 7 3 1 The unit is switched to one of the above statuses Refill only with S10A The unit is refilling fluid Green R and S16A R Fill system only with The installation is filled with fluid Green S10A R and S16A R
22. t screw at step 3 Press EXIT two times The status menu shows the message Err 7 when the test of the run dry protection has been completed successfully Open the valve F in the outlet Press MENU Select Manual operation using A and V Press ENTER Select Reset using A and V Press ENTER NOTE The green LED OK indicates that the unit is ready for use The degassing starts by default daily at 08 00 hours User manual version 1 SPIR TECH PERFORMANCE FOR BETTER Check operation 1 Manually start the unit see 5 5 2 2 Check the indication of the pressure gauge B This should alternately display overpressure and underpressure 3 Close the valve A behind the pressure gauge 4 Put back the cover C on the unit and fasten it with the bolts EP NOTE The SmartSwitch will automatically turn off the unit when the concentration of dissolved gases has reached the minimum level 5 5 Install and operate 5 5 1 Install Set the user parameters 1 Press MENU Select Settings using A and V Press ENTER 2 Select the parameter to be changed using A and V Press ENTER 3 Change the setting using A and V Press ENTER Repeat steps 2 and 3 if necessary gt 5 Repeatedly press EXIT to return to the status report SPIROVENT SUPERIOR Parameter Description Block time day 2 See Block time day 1 Block time week Days of the week on which the unit is not working Select
23. tion overpressure 5 Loosen the air vent screw A see figure on the When a pump has not run for 96 hours an previous page a few turns and tighten the screw automatic pump test is run at the first next Auto again when air has stopped coming out start 6 Repeat steps 3 5 until water starts coming out of Press ON OFF to switch off the unit Press ON OFF the air vent screw at step 5 again to switch on the unit again 7 Press EXIT two times The status menu shows the At low fluid temperatures condensation may occur message Err 7 when the test of the run dry at certain parts The condensation is drained protection has been completed successfully through the openings in the frame 8 Press MENU Select Manual operation using A With the types S10A R and S16A R The amount of and V Press ENTER fluid that is added B depends on the difference A 9 Select Reset using A and V Press ENTER between the system pressure and the water pipe pressure EF NOTE The green LED OK indicates that the unit is S10 ready for use 5 5 5 Reading the memory During operation the following data are stored in the 700 memory 600 Accumulative running hours Degassing history 399 8 10 bar Fault history 400 5 8bar Refilling history only with types 10A R and S16A a R The memory can be read in the following way 200 1 Press MENU Select User menu gt History using A and V Press ENTER 2 Select Fault historyorAction history u
24. ypes S10A R and S16A R SPIROVENT SUPERIOR Problem Possible cause Correction Err 1 Psystem too low The system pressure is too low A failure in the installation Provide a system pressure that is within the application range of the Superior There is a leak in the installation Repair the leak The pressure sensor O is defective Replace the pressure sensor Err 2 Psystem too high The system pressure exceeds the set maximum A failure in the installation Provide a system pressure that is below the set value The set value is too low Increase the set value The pressure sensor O is defective Replace the pressure sensor A valve in the outlet is closed Open the valve The outlet line T has been obstructed Remove the obstruction Err 10 Refill flow too low There is no or little supply of refill fluid A valve in the refill line is partly closed Open the valve The solenoid valve H in the refill line does not open Replace a part of the solenoid valve The refill line has been obstructed Remove the obstruction The water flow meter I is defective Replace the water flow meter Err 11 Refill valve Undesired supply of refill fluid The refilling does not stop The solenoid valve H in the refill line does not close Replace a part of the solenoid valve Err 13 Refill freq too hi