Home

LCD Console Tray CFP185KMM

image

Contents

1. We suggest that the VGA cable is not more than 5 m 5 Computer start normal but the keyboard is not working Make sure other keyboard can be working if it connect to this computer Check the signal cable is connected or not 6 Computer can not detect the mouse Make sure other mouse can be working if it connect to this computer Avoid press the key of mouse or pull out the signal cable when you switch channel Avoid shut down the computer when you switch channel 7 Because the monitor need 1 2 second for display different models so that the scan time should set more than 5 seconds 8 When windows OS show the following informationWindows did not detect a mouse attached to the computer you can safely attach a serial mouse To attach a mouse to PS 2 mouse port you must first turn off the computer Please tick Do not show this message in the future To finish Booting Windows O S 9 When the SUN servers is starting which the edition of OPEN BOOT below 5 0 don t operate the function key like STOP A before it finish the booting device 10 If forgetting the password you typed please contact your supplier Specifications Project Display function Keyboard and mouse The built in power supply module Two choose one Power Working environment Physical features Name Recommended resolution Visual area Backlight LCD adjustment LCD on off Keyboard keys Mouse button Compatibilit
2. 4 81 3 54032919 Korea T 82 2 34831500 F 82 2 5927886 Malaysia T 603 78845000 F 603 78845188 New Zealand T 64 3 3392060 F 64 3 3392063 Pakistan T 92 42 36622526 to 28 F 92 42 36622530 Philippines T 63 2 7207400 F 63 2 6203693 Singapore 65 64672211 65 64670130 Thailand T 66 2 6178260 F 66 2 6178277 to 78 Vietnam T 84 4 37628908 F 84 4 37628909 Marketing ap emerson com www EmersonNetworkPower Asia While every precaution has been taken to ensure accuracy and completeness herein Emerson Network Power assumes no responsibility and disclaims all liability for damages resulting from use of this information or for any errors or omissions Specifications are subject to change without notice Emerson Network Power and Liebert are trademarks of Emerson Electric Co or one of its affiliated companies All other names and logos referred to are trade names trademarks or registered trademarks of their respective owners 2015 Emerson Electric Co APT5ENT CFP185KMM V1 UM EMERSON CONSIDER IT SOLVED
3. LCD Console Tray CFP185KMM User Manual EMERSON Network Power Attention 2 SII s 3 General LUE E PIONS seh Seta 4 CSCIC PR 6 Rack MOuUNUNg 6 Connecting Equipment _ 7 8 Begin USC 8 Monitor OSD 9 Other functional operation _ 9 OUD IC SPOOLIING E ED Um 10 SD SC IC el Ol 11 atention 1 please read this user manual before you use it 2 be care for attribute of power you must pull out the display part of this set before you use it 4 the power will auto turn on or turn off when you pull it out or push it in 50 The panel can be open to 110 for using 6 Please make sure that the OS of your computer support hot plugging or not and read the part about hot plugging of user manual 7 We suggest that you should set the resolution of monitor at 1366 768 60Hz a General description CFP185KMM is a console that integrates the KVM Switch function of multiple ports in 1U It can manage multiple computers through a single set of console LCD monitor keyboard and mouse There is no better way to save space and money than with a CFP185KMM Setup is fast and easy plugging cables into
4. ents can be removed and added back into the installation by unplugging their cables from the PC connection Ports without the need to shut the unit down There are certain procedures that must be followed in order for hot plugging to work properly x Note Some O S Operation Systems like SCO Unix are unable to support Hot Plug function If you apply Hot Plug to this kind of O S it will cause unpredictable behavior or shut down the PC Before attempting to use Hot Plug please make sure your O S and software driver supports the Hot Plug function If it happen unusually the mouse will stop working In order to make sure the system down will not occur for the unusual state you should plug down the signal cable of CFP185KMM and insert back the CFP185KMM after 10 second the system will become normal Shutdown e Press the LCD POWER shut down the LCD power LED is off e Close down the front panel e Push Front panel module in properly the power is off automatically 10 Troubleshooting 10 Make sure all of the cable is connected the CFP185KMM signal cable is not be connected wrong Please bundle the cable of PC and mark it 2 We suggest that the VGA cable is not more than 5 m Don t press the key board when the system is starting because the system may do not find the keyboard 4 When you use the Cable USB please set your PC BIOS to enable USB function if PC can t work properly
5. ng equipment CFP185KMM signal line and it s use of connection CFP185KMM power cord and it s use of connection Wide voltage range Applicable models AC power cable 96 264VAC 47 63Hz AC power input 220V AC power cable Begin to use e Press the unlock switch e pull KVM Drawer panel module out and the slide rail is locked automatically Power 1 on e Release the front panel locker PRESSUNLOCK e his can open the display part be open to 110 degree Note the open angle can not be more than 110 otherwise it may damage the equipment Pm 110 Press the LCD Power button when the LED indicator is on Monitor OSD menu Adjust of Display function depend on LCD OSD Key Specific control key functions such as table Control key name Function description LCD POWER Turn on and off the monitor power MENU Calls OSD menu AUTO auto adjust SL SL Moves the selector left and right on the OSD menu Blue normal Purple Red Blue power saving mode Indicator Status disconnection of signal cable Please press the AUTO key if the screen s excursion occurs during starting the machine switching to other channels or at other cases then the screen will be adjusted automatically to reach the best display status We suggest the clients set the display mode at 1366x768 60Hz Other functional operation Hot swap The CFP185KMM supports hot plugging which means that compon
6. their appropriate ports is all that is entailed There is no software to configure so there is no need to get involved in complex installation incompatibility problems CFP185KMM8 16 works on any hardware platform and with all operating systems Features Integrated LCD display keyboard mouse and switch e 18 5 inches LED energy saving display e Scissors foot type ultra thin notebook keyboard The machine adopts the towline type protective design and signal cable design to avoid loss caused by the repeated pumping High quality dedicated slide rail Overall 1U height suitable for standard cabinet installation Do not need to install the software and allow to operate directly the computer Built in 90 264V AC power supply Optional 48V Telecom stage DC power supply Provide safety protection of telecommunication level Automatic power protection design When not using the device which is to promote the cabinet automatically enter protected mode Meet DDC DDC2 DDC2B standards comply with VESA standards Appearance Front view 1 LCD display 2 Keyboard 3 Mouse 4 Slide rail lock 5 LCD OSD key board Rear view 1 2 2 No Description 1 PC connection port 2 Power input port 3 Earthing point Structure size Installation Rack Mounting Installation requirements CFP185KMM conforms to the standard 19 cabinet suitable for cabinet installation depth 600mm 850mm Connecti
7. y AC power input DC power input Recommended working Storage temperature Humidity Shell Machine net weight Equipment size length x width x high CFP185KMM Specification parameter 1366 x 768 DDC2B 18 5 Inch LED 4 x Button 1 x Button 100 Key 83 Key keyboard 17 Key independent digital keyboard 2 x Button Support Windows Microsoft system support MAC system support LINUX UNIX NETWARE system 90V 264V AC 36V 72V DC 20W 0 50 20 60 0 80 RH No condensation Metal Plastic 10kg 594 5mm x 481mm x 42 5mm About Emerson Network Power Emerson Network Power a business of Emerson NYSE EMR delivers software hardware and services that maximize availability capacity and efficiency for data centers healthcare and industrial facilities A trusted industry leader in smart infrastructure technologies Emerson Network Power provides innovative data center infrastructure management solutions that bridge the gap between IT and facility management and deliver efficiency and uncompromised availability regardless of capacity demands Our solutions are supported globally by local Emerson Network Power service technicians Learn more about Emerson Network Power products and services at www EmersonNetworkPower Asia Stay connected in EJEM Emerson Network Power Asia Australia T 1800 065345 F 61 2 97810252 Indonesia T 62 21 2513003 F 62 21 2510622 Japan T 81 3 5403856

Download Pdf Manuals

image

Related Search

Related Contents

Le DUER : mode d`emploi - Analys  Media-Tech MT1065C mice  User Manual - White Magic Software  Link to Elchrom GEPS Power Unit User Manual …. pdf  Analysis and Design of a Redundant X-by  取付・取扱説明書 - Dynamic DO!.jp    Acer Aspire AS5750G  `ー 趣 旨 県民の日記念行事については 山梨県環境にやさしいイベント  

Copyright © All rights reserved.
Failed to retrieve file