Home

Automatic Blow-Clear Equipment Version 3.1-3.4 Protected

image

Contents

1. Automatic Blow Clear Equipment Version 3 1 3 4 Protected Version 2008 Hacker amp Petermann GmbH Sonnengasse 13 A 9020 Klagenfurt tel 43 0 463264527 fax 43 0 463 913706 mobile 43 0 676 845435 ext 100 200 e mail office hacker petermann at www hacker petermann at UID ATU 57917927 Copyright 2008 Hacker amp Petermann Ltd Bluefly Freiblaseinrichtung All rights reserved Hacker amp Petermann Ltd reserve the right to change or to withdraw features offered without advance notice Hacker Petermann Ltd Sonnengasse 13 A 9020 Klagenfurt Austria Carinthia Thank you for your purchase and for placing your trust in our Bluefly Blow Clear Equipment For economic and technological reasons modern day fire prevention often involves using smoke in take systems to detect fire Unfortunately these generally very good systems come with a costly disadvantage Because air is sucked in through the pipe system inlets fine dust is sucked in too After a period of some months depending on the environment this fine dust clogs the inlets Besides leading to a breakdown in the smoke in take system this could even result in a fire being detected too late or not at all It is because of breakdowns in the smoke in take system that pipe system maintenance and cleaning usually come at such a high cost With our BLUFLY Blow Clear System you can say goodbye to maintenance and cleaning costs and to increased risks Once
2. installed Blow Clear uses compressed air to clean the pipe system fully automatically and at intervals of your choosing The comparatively low purchase price will be repaid in no time because of the savings you make on the costs of breakdowns If you are interested or you have got questions or improvement suggestions or queries please contact us in person or on the telephone numbers given above We will be pleased to give you advice We are available at any time on the following mobile number 43 0 676 845435 ext 100 200 Copyright 2008 Hacker amp Petermann Ltd Bluefly Freiblaseinrichtung All rights reserved Hacker amp Petermann Ltd reserve the right to change or to withdraw features offered without advance notice The automatic Blow Clear control unit Type 3 1 for smoke in take systems using 1 sensor pipe network Technical data Electrical connection Valves to the suction side Compressed air connection Sensor pipe suction pipe Reset contact 1 A B Input contact la Input contact 2 Output contact Protection class Temperature range Max height of installation location Distance between sensor pipes 10cm 230 V AC 1 5 mm G 1 for minimal and negligible intake pressure loss Internal pressure reducer max 10 bar oil free pressured air using a standard compressed air quick coupling Working pressure adjustable depending on sensor pipe length max 5 bar 25 mm plastics connection for b
3. to SIS Protection class IP65 with a transparent control element cover Temperature range from 5 to 45 C Max height of installation location 2500 m above sea level Distance between sensor pipes 10cm Suitable for use only inside buildings with standard environmental conditions No acidic ambient air Dimensions Width 700 mm Height 500 mm Breadth 150 mm Timer control Number of blow clearing standard 6 times a day Time slice freely adjustable Optional e Case made of stainless steel e Internal adjustable cabinet heating Copyright 2008 Hacker amp Petermann Ltd Bluefly Freiblaseinrichtung All rights reserved Hacker amp Petermann Ltd reserve the right to change or to withdraw features offered without advance notice Technical User Manual for Blow Clear Equipment For all technical questions ask your reseller or Mr Markus Petermann from Hacker amp Petermann GmbH support on phone number 0043 0 676 845435 200 Installation The Blow Clear system must be installed between your smoke in take system and the pipe network More specifically the Blow Clear apparatus should be installed immediately behind the smoke in take system We suggest to install possible filter etc between the SIS and our automatic Blow Clear System because this components could be damages by the pressured air Ask your filter supplier for more information We recommend to fix our system firmly onto the wall using dowels an
4. ange or to withdraw features offered without advance notice The Blow Clear control unit for smoke in take systems using 3 sensor pipe network Technical data Electrical connection 230 V AC 1 5 mm Valves to the suction side G 1 for minimal and negligible intake pressure loss Compressed air connection Internal pressure reducer max 10 bar oil free pressured air using a standard compressed air quick coupling Working pressure adjustable depending on sensor pipe length max 5 bar Sensor pipe suction pipe 25 mm plastics connection for bonding Reset contact 1 A B N O contact potential free Closes for a second every time before and or after or during blow clearing takes place This is so that provided it is compatible with the air intake system the error message low air flow is suppressed during blow clearing or for cleaning is deactivated Input contact la Input contact for unscheduled blow clearing by means of a SIS signal or manually Input contact 2 Input contact to suppress blow clearing if fire alert is detected by SIS Output contact Output contact for error messages to SIS Protection class IP65 with a transparent control element cover Temperature range from 5 to 45 C Max height of installation location 2500 m above sea level Distance between sensor pipes 10cm Suitable for use only inside buildings with standard environmental conditions No acidic ambient air Dimensions Width 700
5. d screws You should use the prepared four holes Especially by the IP 65 model we advise the usage of screws with sealings The Blow Clear System should be connected with the standard plastic pipes of your smoke in take system Please open the plastic screwing 1 of the lower suction pipe and on the upper sensor pipe and push the plastic pipes of your SIS through the provided holes 2 Than glue the pipes sealed with your standard adhesive into the pipe coupling 3 By screwing down the plastic screws 1 after the adhesive is cured the case will be sealed The compressed air quick release coupling 4 must be connected with oil free compressed air of between 2 and max 10 bar Make sure that the compressed air supply is sufficient Copyright 2008 Hacker amp Petermann Ltd Bluefly Freiblaseinrichtung All rights reserved Hacker amp Petermann Ltd reserve the right to change or to withdraw features offered without advance notice Electrical connections As the cable entry 5 is situated at the bottom the system can be connected to the mains supply as well as to the smoke intake system if necessary The Bluefly Blow Clear System operates on an alternating current of 230 volts Connect up to the terminals as follows Live black Neutral blue Protective Earth green yellow The in and output contacts will be connected depending on programming Further information you can find in the circuit diagrams Adjust t
6. ear System Setting the Blow Clearing Intervals amp Programming Bluefly Blow Clear Systems are delivered factory adjusted to meet the customer s requirements Only the time setting for the blow clearing has to be changed if necessary If you want to set the blow clearing times you need the Logo Soft 5 software and a data cable In the supplied control program you only are allowed to set the two timers on the upper left side Double click on the timer and change the Nocken 1 3 your blow clearing times analog to the old one That means from 07 00 and 07 01 you can make 14 30 and 14 31 The one minute delay is only for the program All changes in software have to be made by professional personal Consequential damages are excluded from any possible warranty or liability claim For any further information please contact us on the telephone numbers given before Copyright 2008 Hacker amp Petermann Ltd Bluefly Freiblaseinrichtung All rights reserved Hacker amp Petermann Ltd reserve the right to change or to withdraw features offered without advance notice Operation mode of the Bluefly Blow Clear Equipment Once it has been assembled according to the instructions and connected to the mains Bluefly Blow Clear Equipment is ready for operation Under normal operating conditions for smoke detection the air from the sensor pipe network is sucked through our Blow Clear System into the smoke in take system In order to minimise
7. eated for each sensor pipe line When the compressed air valve is closed the 1 inch valve to the suction pipes opens again and the SIS again sucks air from the cleaned sensor pipe network This resetting of normal operating conditions is marked by A amp B1 message contact closing for one second to ensure that the SIS remains enabled Depending on the programming this procedure can be repeated up to six times at set times Copyright 2008 Hacker amp Petermann Ltd Bluefly Freiblaseinrichtung All rights reserved Hacker amp Petermann Ltd reserve the right to change or to withdraw features offered without advance notice
8. essured air using a standard compressed air quick coupling Working pressure adjustable depending on sensor pipe length max 5 bar Sensor pipe suction pipe 25 mm plastics connection for bonding Reset contact 1 A B N O contact potential free Closes for a second every time before and or after or during blow clearing takes place This is so that provided it is compatible with the air intake system the error message low air flow is suppressed during blow clearing or for cleaning is deactivated Input contact la Input contact for unscheduled blow clearing by means of a SIS signal or manually Input contact 2 Input contact to suppress blow clearing if fire alert is detected by SIS Output contact Output contact for error messages to SIS Protection class IP65 with a transparent control element cover Temperature range from 5 to 45 C Max height of installation location 2500 m above sea level Distance between sensor pipes 10cm Suitable for use only inside buildings with standard environmental conditions No acidic ambient air Dimensions Width 700 mm Height 500 mm Breadth 150 mm Timer control Number of blow clearing standard 6 times a day Time slice freely adjustable Optional e Case made of stainless steel e Internal adjustable cabinet heating Copyright 2008 Hacker amp Petermann Ltd Bluefly Freiblaseinrichtung All rights reserved Hacker amp Petermann Ltd reserve the right to ch
9. he internal pressure reducer In order to save you further costs our new automatic blow clear system has a serial pressure reducer with a manometer 6 This one allows you to reduce the standard pressure of your pressured air supply with about 8 10 bar to the optimal working pressure We advise to begin with a pressure of approximately 2 bar and to increase pressure depending on sensor pipe length Maximal pressure should be 5 bar because you loose warranty of valves with higher pressures Attention Our new automatic blow clear system type 3 contain 4 pressure valves which allows a higher air flow with the same working pressure So the pressure and the airflow has to be adjusted with the pressure reducer Copyright 2008 Hacker amp Petermann Ltd Bluefly Freiblaseinrichtung All rights reserved Hacker amp Petermann Ltd reserve the right to change or to withdraw features offered without advance notice Included Protection class IP65 with folding upwards control element cover for better protection against water dust and contact to electrical parts Internal pressure reducer with manometer This one allows you to reduce the standard pressure of your pressured air supply with about 8 10 bar to the optimal working pressure We advise to begin with a pressure of approximately 2 bar and to increase pressure depending on sensor pipe length Maximal pressure should be 5 bar because you loose warranty of valves with higher pre
10. loss of intake pressure because of the flow resistance of valves we only use top quality 1 inch magnetic valves Tests undertaken by a leading manufacturer of smoke in take systems have shown that loss of intake pressure is in fact negligible In its stand by state oil free compressed air which is connected to our system by means of customer friendly standard couplings is drawn into the internal pressure reducer With the pressure reducer you have to adjust the working pressure Then the pressured air drawn into compressed air valves For each sensor pipe line we use a separate compressed air valve to avoid increasing the quantity of air that has to be supplied by the compressor The air flow depends on sensor pipe length and number of suction holes and is about 200 350 liter per minute During clearing the 1 inch valves close the suction line In this way the SIS is separated from the sensor pipe network When the suction line is closed we can make this known to the smoke intake system provided it is compatible by momentarily closing the A amp B1 message contact in order to suppress the error message low air flow or to deactivate it during blow clearing After a short delay the first compressed air valve opens again and compressed air is allowed to flow through the first sensor pipe for 20 to 30 seconds Thus the network can be blow cleared of precipitates Afterwards the compressed air valve closes again and the process is rep
11. mm Height 500 mm Breadth 150 mm Timer control Number of blow clearing standard 6 times a day Time slice freely adjustable Optional e Case made of stainless steel e Internal adjustable cabinet heating Copyright 2008 Hacker amp Petermann Ltd Bluefly Freiblaseinrichtung All rights reserved Hacker amp Petermann Ltd reserve the right to change or to withdraw features offered without advance notice The Blow Clear control unit for smoke in take systems using 4 sensor pipe network Technical data Electrical connection 230 V AC 1 5 mm Valves to the suction side G 1 for minimal and negligible intake pressure loss Compressed air connection Internal pressure reducer max 10 bar oil free pressured air using a standard compressed air quick coupling Working pressure adjustable depending on sensor pipe length max 5 bar Sensor pipe suction pipe 25 mm plastics Reset contact 1 A B N O contact potential free Closes for a second every time before and or after or during blow clearing takes place This is so that provided it is compatible with the air intake system the error message low air flow is suppressed during blow clearing or for cleaning is deactivated Input contact la Input contact for unscheduled blow clearing by means of a SIS signal or manually Input contact 2 Input contact to suppress blow clearing if fire alert is detected by SIS Output contact Output contact for error messages
12. onding N O contact potential free Closes for a second every time before and or after or during blow clearing takes place This is so that provided it is compatible with the air intake system the error message low air flow is suppressed during blow clearing or for cleaning is deactivated Input contact for unscheduled blow clearing by means of a SIS signal or manually Input contact to suppress blow clearing if fire alert is detected by SIS Output contact for error messages to SIS IP65 with a transparent control element cover from 5 to 45 C 2500 m above sea level Suitable for use only inside buildings with standard environmental conditions No acidic ambient air Dimensions Width 350 mm Height 450 mm Breadth 150 mm Timer control Number of blow clearing standard 6 times a day Time slice freely adjustable Optional e Case made of stainless steel e Internal adjustable cabinet heating Copyright 2008 Hacker amp Petermann Ltd Bluefly Freiblaseinrichtung All rights reserved Hacker amp Petermann Ltd reserve the right to change or to withdraw features offered without advance notice The Blow Clear control unit for smoke in take systems using 2 sensor pipe network Technical data Electrical connection 230 V AC 1 5 mm Valves to the suction side G 1 for minimal and negligible intake pressure loss Compressed air connection Internal pressure reducer max 10 bar oil free pr
13. ssures Attention Our new automatic blow clear system type 3 contain 1 4 pressure valves which allows a higher air flow with the same working pressure So the pressure and the airflow has to be adjusted with the pressure reducer Input contact for unscheduled blow clearing by means of an SIS signal or manually by installed button Here an input contact I1 is installed which activates the blow clearing in case the signal e g of the smoke intake system is not available e g error message line blocked Input contact for suppressing a blow clearing if a fire alert is detected by SIS while clearing should happen by schedule Output contact for error message Here an output contact O1 amp 2 NO switch is installed that can for instance depending on the programming signal that after unscheduled blow clearing the SIS input signal e g error message line blocked is still not activated Copyright 2008 Hacker amp Petermann Ltd Bluefly Freiblaseinrichtung All rights reserved Hacker amp Petermann Ltd reserve the right to change or to withdraw features offered without advance notice Optional e Case made of stainless Steel for bad environmental conditions recommended by law or just for a better design e Equipment cabinet heating To protect the technical equipment against lower temperatures etc a pre assembled equipment cabinet heating is available It can be readily integrated into the Blow Cl

Download Pdf Manuals

image

Related Search

Related Contents

施工説明書  User Manual UTC-318  Sylphide 取扱説明書  THEME Edition 2013 - La Foire de Libramont  出会い系サイト」に係る児童買春等の被害から年少者を守るため  The Blüthner Digital Model One  毎言語fィ『一 ,”  OWI P8378P User's Manual  Samsung 205BW Инструкция по использованию  GameCamera Came ra m aer ame Ca C GameC eC ame Ga G ar  

Copyright © All rights reserved.
Failed to retrieve file