1. is pressed programmable on the remote telephone upto 12VDC at upto 400mA will be provided to the Door strike coil for 3 seconds programmable Independent contacts on the Green pair are also controlled by the Door Strike operation The Door Latch code and the duration of the relay ON time can be programmed see command list Page 4 of 8 4 5 DS Series Door Station Revision 22 NFcomms User Manual Cabling The Door Station cabling should be installed according to AS NZ 3086 Telecommunications Installations Integrated telecommunications cabling systems for small office nhome office premises If the Cable Tail wires will be subjected to weather conditions they should be connected using silicon filled telecom insulation displacement connectors to ensure weather proofing of the connections 8 Bluewhite Line J ory aie aa To PABX 6 partion Dowel o To plug pack white LLL or Premier 5 Orange Power S Pair 2 4 Green C ommon white 3 Green NO switch COALS 12V 12V to Hi Door strike Lo oa To Door Strike coil Brown Door Strike ee eee E A Uncommitted white return Brown Pair Door Latch relay contacts These terminals provide a nominal 10 12V 450mA DC supply to operate a Door Latch coil when the Door Latch code is sent These terminals can be connected directly to a door latch coil These terminals are protected from temporary accidental shorting NOTE Internal strap must be fi
2. Busy tone Hangup Option 79 72 hangup if busy tone detected 73 ignore busy tone Door Relay tone 77 76 No tone when Door relay on 77 Tone when Door relay on Door Relay option 79 78 Door Relay ON always when ONLINE 79 Door relay operates on Door code Immediate 8 x Action 80 Deactivate Door Relay 81 Activate Door Relay 82 Sound software version Hangup 9 Causes the Door Station to hangup Note Door Station also disconnects on code 99 and in response to DTMF B and C tones Page 8 of 8
3. NFcomms User Manual DS Series Door Station Revision 22 DS Series Door Station User Manual For Hardware Rev 3a or higher Note New command 6 tor hw rey a Revision 22 Copyright 2008 NF Communications NFcomms Designed and Manufactured in Australia by NF Communications P L Anthony Street Ormond VIC 3204 Tel 03 9525 7195 Fax 03 9525 7196 Web www nfcomms com au Page 1 of 8 DS Series Door Station Revision 22 NFcomms User Manual Page 2 of 8 DS Series Door Station Revision 22 NFcomms User Manual 1 Introduction The DS Series Door Station series is intended as a hands free speaker telephone situated at a door or gate and is connected to a suitable analogue extension of a PABX or key system such as the Datis Hitec Premier SOHO PABX Pressing the button of the Door phone will initiate the automatic sending of a DIMF number sequence which will be analysed and handled by the PABX The DS Series is suitable for flush mounting in any wall with a cavity about the size of half a standard house brick A surface mounting bracket option is available 2 Features Sealed to IP54 for protection against rain water splashes and dust Voice circuit is Line powered so main function will still work if external power fails External plug pack power required for Door strike and optional camera Stainless Steel or Brass front panel options Multiple button model to access different areas An
4. ated power or 15VAC power rated at 500mA This can be provided from the extension ports of the Premier PABX itself pair 2 power or from a plug pack The Premier s auxiliary power feed can be used to power both the Door Station s LEDs and an optional Door Strike coil provided the Door Strike coil needs less than 400mA at 12V There is insufficient power from the Premier to feed the DS Series with the Camera option so an external plug pack is required if the camera option is fitted Summary of Power requirements Hands free Door Relay Door Relay Telephone LED LED Camera Connection Through PSTN Orange Pair Orange Pair or PABX line non polarized non polarized Voltage Line Powered 15 24VDC or 15 24VDC or nominal 48V 15VAC 15VAC or 24V Current Line Powered 400mA 800mA nominal minimum minimum 25mA Set up Various parameters on the DS Series can be Programmed refer section 4 The DS Series Door Station by default sends the DTMF sequence 27 when the Door Button is pressed and 28 if the 2 button is pressed on 2 button models If connected to the Datis Hitec Premier SOHO PABX all telephone extensions will ring when 27 or 28 is dialled The Premier will need to be programmed if selected extensions are required to ring Refer to Premier Programming manual for information on how to program selective ringing for extensions Door Strike A door strike coil can be connected directly to the brown pair When key 2
5. en call button 1 is pressed nnnn is 1 to 15 digits long Note to enter a in the Destination number use the button cannot use the button because this will end the entry Change the number sent when call button 2 pressed nnnn is 1 to 15 digits long Note to enter a in the Destination number use the button cannot use the button because this will end the entry Call automatically clears after x minutes x is 0 to 9 minutes 0 indicates no timeout DD is a 1 or 2 digit code using digits 0 9 Code DD can be entered during any call to activate the Door Rela lt option gt is the cadence of the tone on answer selection 0 selects no tone on answer 60 Set 6 options to default values 63x Sets Microphone sensitivity to x x 0 is lowest sensitivity x 7 is highest sensitivity 67x Sets volume level of speaker to x x 0 is lowest volume x 7 is highest volume 68x Sets balance between speaker amp microphone x 0 most emphasis on mic x 7 most emphasis on speaker Sets Answer Mode x 0 Manual answer via Call Button x 1 Automatic answer default Page 7 of 8 4 seconds 4 minutes 1 tone on Default is x 3 for each setting DS Series Door Station Revision 22 NFcomms User Manual Command DTMF codes Example Comment Default Options 7 lt option gt Button Flash Option 70 no button LED flash 4 71 flash button LED when call active
6. ould be reserved for the emergency access telephone for use when power fails Refer to the Premier User Manual Premier PABX i i Fig 2 The 8 RJ12 extension ports of the Premier PABX 4 6 Volume and Microphone sensitivity Adjustment Both Volume and Microphone sensitivity can be adjusted remotely by command This allows the unit s parameters to be tuned to suit the environment that it is in Programming Various parameters can be programmed on the DS series Door Stations A call must be made into the unit with a standard analogue DTMF capable telephone The unit must have the answer strap fitted to answer the call Commands can then be entered using the telephone buttons to change the parameters Changes survive power down Commands are started with Successful commands are acknowledged with 2 short beeps Failed commands or actions are indicated by 1 long beep Page 6 of 8 Command Door Relay ON time Change Destination number Change Destination number Change Call Duration time Change Door Relay code Tone on Answer Level Control and Answer Mode DTMF codes 0 XX 1 nnnn 2 nnnn 3X 4 DD 5 lt option gt 6 lt option gt lt level gt DS Series Door Station User Manual NFcomms Revision 22 0 10 0 4 10395251234 2 28 This example will store the digits 28 for button 2 Door Relay ON time in seconds 1 to 29 secs Change the number sent wh
7. ti vandal construction Flush or Surface mount Electronic control of Volume and Microphone sensitivity to adjust unit to local environments Improved Busy tone detection to suit most PABX types 3 Compliance The DS series Door Station is fully approved and meets the Australian Communications Authority ACA requirements for Electrical Safety Telecommunications and Electromagnetic Compatibility EMC Warning The DS Series Door Station has been designed for connection to a PABX and is not approved or intended for direct connection to the Public Switched Telephone Network PSTN Page 3 of 8 4 4 1 4 2 4 3 4 4 DS Series Door Station Revision 22 NFcomms User Manual Installation Mounting the Front panel Flush mount units should be fitted in a cavity size as specified and fixed using wall plugs or other suitable fixings Suggested hardware is 25X6mm wall plugs and 8G stainless steel tamper torx screws which can be supplied on request Refer to separate instructions supplied with the various brass and stainless steel front panels surface mount brackets and plastic units Power Supply The telephone section of the Door Station is Line Powered from the telephone line The Door Station will need to charge up when first connected to the line this may take upto 30 seconds This charge will remain for a few days if removed from the line The Door Station relay driver and LED will require 15 to 24V DC unregul
8. tted Green Pair Uncommitted Normally Open NO contacts Door Latch relay contacts that operate when the Door latch code is sent These contacts are rated at 1A 30VDC NOTE Internal strap must be removed unit is EE delivered with strap removed PRENION port viewed from front with contacts at bottom Orange Power Pair Power for the unit can be supplied Pair 1 Line pin 4 L 1 directly from the Premier PABX via pair 2 of the Premier s aaa modular RJ12 extension port The inner pair pair 1 of the c NX Ne modular connector RJ12 plug is the extension line pair so eee pin 5 neg 2 or from a 15 to 24V DC or 16 18V AC 500mA plug pack pin 2 pos The Door Station power terminals are non polarized the DC cables can be connected either way Note The voice circuit of the Door Station is line powered and will operate without external power The Plug pack power is required only to supply power to the LED and the Door relay and external Door Strike coil and optional camera if fitted Page 5 of 8 DS Series Door Station Revision 22 NFcomms User Manual Blue LINE pair Voice Line pair Connect a category 5 cable between the Front panel unit and the PABX The cable can pass through the premises Distribution Device DD Note If using the Premier SOHO PABX the Door Station can be connected to any extension of the Premier however it is suggested that extension 8 not be used for the Door Station as this sh

Download Pdf Manuals

image

Related Search

Related Contents

医政指発 0927第 ー 号 - 公益社団法人 茨城県看護協会  Philips Ledino Pedestal/post 16357/87/16  Optimus 14-1121 Microcassette Recorder User Manual  Zebra MC3190  Manual del Usuario para Nokia E50 - File Delivery Service  cemento bío bío especial siderúrgico planta - Cementos Bío  BN 160M...BN 200 - Tecnica Industriale S.r.l.  Churchill A.V.R.E.  