Home
GEC9 OWNER S MANUAL
Contents
1. change the bank the numerical bank display blinks when the bank is about to be changed Press any preset switch to recall new bank presets 7 Programming Program keys are inactive when the pedal works in bypass mode All presets LED are off the keys will be active when a preset is active press the program keys to turn on off corresponding Loops the loop status LED will be on off accordingly All loop on off status are automatically stored into non volatile memory which will be still available even the power supply is removed 4 8 Specifications 5 16 9 L x3 8 W X1 22 H inch WUC GM MT 18000 Power Supply nien DC9V Negative Center UIT IIE DPA Ii E max 350mA MOU Impe OAC Bose tent cate te a doo uae 500K ohm vise 10K ohm Max Buffered 2 222 2 9V Non Buffered 30V Typical Configuration 1 Connect 9 pedals LOOP3 LOOP4 ee 0000000 OO Configuration 2 Separate loops as footswitch In this configuration the separate loop send jack 57 58 59 are used to control the amplifier channels The amplifier preamp is connected to GEC9 LOOP1 makes it possible to add modulation effects to the preamp
2. LOOP3 LOOP4 LOOP1 AMP PREAMP DON NBUF IN LOUT1 Swa R1 0 CLEAN IN7 R8 OUT8 N O o OFT 9 9 SEND RETURN AMP HEAD CABINET Configuration 3 Use multiple amplifiers In this configuration the separate loop9 is used to choose signal path to different amps LOOP5 LOOP6 229308 LOOP1 LOOP2 LOOP3 BUF IN DC9V NBUF IN LOUTI R LOUT2 OSs BUF OUT A 0 LEAN 7 0009000 LOOP9 TO CHOOSE SIGNAL PATH AMP2 z INPUT FOOTSWITCH SEND RETURN I INPUT FOOTSWITCH SEND RETURN Configuration 4 Control Pedals ext loops This setup put 6 pedals LP1 LP2 LP3 LP4 LP5 LP6 in front of AMP and 3 pedals LP7 LP8 LP9 into AMP LOOP Preset example 1 ON 0 0 PRESETI LP4 LP2 LP7 LP8 LP9 10 10 10 1 0 1 the signal flow is GUITAR FX1 FX3 FX5 Preamp FX7 FX9 Power AMP PRESET2 LP1 LP2 LP7 LP8 LP9 2 0 1 11 110 0 1 thesignalflowis GUITAR FX2 FX3 FX4 FX5 FX6 Preamp FX9 Power AMP Pedals in front of AMP BUF IN DC9V NBUF IN oes OFT
3. ck 5 9 X 2 1 mm type use negative center DC 9V 500mA power supply 9 NBUF IN Non Buffered input This jack bypasses the buffer circuit and directly sends singal to the loops the BUF IN jack is automatically disconnected when a plug is inserted into it 10 LOUT1 and LOUT2 Output jacks for series loops LOOP1 6 the input signal via buffered or non bufferd Input jacks reaches the two jacks via 6 series loops LOUT 1 and LOUT2 jacks are Internally connected in parallel 11 51 This is send jack of LOOP1 connects to input jack of guitar effect 12 R1 This is return jack of LOOP1 connects to output jack of guitar effect 13 EARTH TERMINAL Connect the commander frame to earth through this terminal 14 BUF OUT ALWAYS OUTPUT Singal from INPUT goes through a buffer circuit one branch feeds to LOOP1 LOOP6 The other branch feeds to BUF OUT A O jack 15 CLEAN When LOUT is muted the input signal via buffered or non bufferd reaches this jack 16 IN7 Input of separate LOOP7 17 S7 N C SEND jack of separate LOOP7 this jack should be connected to the input on effect unit When LOOP7 is on signal from IN7 reaches SEND jack enters external effect then back to R7 RETURN jack finally reaches OUT7 jack When LOOP7 is off the signal from IN7 directly reaches OUT7 This jack also functions as latching N C Normally Closed switch which works as footswitch to control amplifier channel The jack is closed open when LP7 is off o
4. illae GEC9 OWNER S MANUAL Guitar Effects Commander Be sure to read this manual before using the product in order to ensure safe operation 1 1 Overview Top Panel 3 B O e Q Q 1 4 2 12 Rear Panel 10 1000000000000 IN7 57 N C R7 OUT7IN O 58 N C OUTS8IN O 59 N C OUT9 N 0 13 14 15 16 17 18 19 1 5 5 These switches instantly recall the settings stored the corresponding PRESET 1 5 when pressed press the active PRESET switch again will bypass whole loops All presets are stored in nonvolatile memory will not be erased even without power supply 2 MUTE CLEAN This switch instantly shuts off the LOOP OUT LOUT1 amp LOUT2 and switches the INPUT to CLEAN jack press it again will get back to normal operation 3 BANK UP DOWN BANK UP DOWN switch increases decreases the BANK there are 10 BANKS A b C d E F G H I J available 4 LOOP1 6 Program Keys These keys turn on off LOOP1 to LOOP6 separately the signal goes through the LOOP when a LOOP is on LED on LOOP off LED off means the LOOP is bypassed 5 LOOP7 9 Program Keys These keys turn on off LOOP7 to LOOP9 separately 6 NUMERICAL BANK DISPLAY Itindicates the active BANK 7 BUF IN Buffered Input Signal input via this jack is fed to a buffer circuit prior to being sent to the loops 8 DC Ja
5. n 18 R7 RETURN jack of separate LOOP7 19 OUT7 N O OUTPUT jack of the separate LOOP7 This jack also functions as latching N O Normally Open switch which works as footswitch to control amplifier channel The jack is open closed when LP7 is off on Note Leave RETURN unplugged 3 2 Signal Path LOOP LOOP2 gt LOOP3 gt LOOP4 LOOP59 add d INPUT o CLEAN LOUT2 BUF OUT A O IN7 LOOP7 OUT7 N89 LOOP8 OUT8 IN9o LOOP9 2 OUT9 Guitar signal feeds into GEC9 input NBUF IN or BUF IN enters series LOOP1 LOOP6 when MUTE switch is off then outputs from LOUT1 and LOUT2 If MUTE is on the signal outputs directly to CLEAN jack The BUF OUT jack always outputs buffered input signal 3 Recall Presetting and Bypass whole loo Press preset switches to recall presettings the corresponding LED lights on when a presetis active Press the active preset switch again will bypass the whole loop the corresponding LED will be turned off Recall bypass operation will not change the MUTE status 5 Mute CLEAN Press MUTE CLEAN switch to mute the LOUT and send input jack signal to CLEAN jack the MUTE status LED will turn on To cancel MUTE function by pressing this switch again MUTE function works individually recall bypass opertations do not change MUTE status 6 Bank UP DOWN GECO have 10 banks from Ato J each bank store 5 presets Press BANK UP or BANK DOWN switches to
Download Pdf Manuals
Related Search
Related Contents
Matrix Appliances MHE001SS hob Defensor ABS2 Montage- und Betriebsanleitung (引渡書)(記載例)(PDF:130KB) dreamGEAR 5 in 1 Gamer Pack for DSi FCPE-LLG Association des Parents d`Élèves tél. : 06 42 92 05 38 RS08 User Manual ダウンロード - ソニー製品情報 Brother PT-D200 label printer diário eletrônico da justiça do trabalho Performance Monitoring using built in processor support in a Copyright © All rights reserved.
Failed to retrieve file