Home
DMX-RELAIS 8 - DMX4ALL GmbH
Contents
1. DMX RELAIS 8 User manual DM ALL DMX Relaisinterface 8 2 Description The DMX Relais Interface has 8 potential free switching outputs make contact Energy Saving Design Due to modern switching technology much less warmth will be generated and so the energy consumption will be lowered Technical Data Power supply 12 24V DC 400 Units before 2014 only 12V 400 DMX Channels 8 DMX FAIL OFF HOLD Outputs 8 Switching output normally open contact max 250 ohmic load Board dimensions 99mm x 82mm LED Display Codes The integrated green LED is a multi function display During to the normal operation mode the LED lights permanently In this case the device is working If the LED is permanently dark there is no DMX512 signal at the entry Furthermore the LED shows the current status In this case the LED lights up in short pitches and then 15 missing for longer time The number of the flashing lights is equal to the event number Status Description Number Addressing error Please check the adjusted DMX address 3 DMxX signal error An invalid DMX input signal is detected Exchange the signal pipelines at Pin 2 amp 3 or use a rotated connecting cable DM DMX Relaisinterface 8 WWW DMK4ALL DE Connection man 2 IN POWER 12 a ADDRESS Biel gt 2 ALL DMX RELAIS 8 RS D
2. MX ALL D MX Rela ISI nte rfa ce 8 4 Addressing The start address is adjustable about switch 1 9 Thereby switch 1 has the 2 1 switch 2 the valency 2 2 and so on up to switch 9 with the valency 28 256 The sum of the switches showing ON are equal to the start address Address Switch Address Switch 508 510 DMX HOLD Function The DMX Relais 8 has DMX HOLD function storing the last value from the failed DMX signal The relays stay in its status lf the DMX HOLD function is not active so all relays are switched off during a failed DMX signal In the case of a power failure the stored value is discarded DMX HOLD is activated with switch 10 Switch 10 ON DMX HOLD activated Switch 10 OFF DMX HOLD not activated DMX worm ALL DMX Relaisinterface 8 Equipment Top hat rail housing 1050 9 Power supply 12V 20W DM ALL D M X Re 151 nte rfa ce 8 6 CE Conformity This assembly board is controlled by microprocessor and uses high frequency 2 To get the characteristics of the assembly in relation to the CE conformity an installation in a compact metal casing is necessary Risk Notes You purchased a technical product Conformable to the best available technology the following risks should not excluded Failure risk The device can drop out partially or completely a
3. ent does not contain assured characteristics The guidance and the characteristics can be changed at any time and without previous announcement
4. t any time without warning To reduce the probability of a failure a redundant system structure is necessary Initiation risk For the installation of the board the board must be connected and adjusted to foreign components according to the device paperwork This work can only be done by qualified personnel which read the full device paperwork and understand it Operating risk The Change or the operation under special conditions of the installed systems components could as well as hidden defects cause to breakdown within the running time Misusage risk Any nonstandard use could cause incalculable risks and is not allowed Warning It is not allowed to use the device in an operation where the safety of persons depend on this device ALL WWW DMX4ALL DE DM DMX4ALL GmbH Reiterweg 2A D 44869 Bochum Germany Last changes 25 08 2015 Copyright DMX4ALL GmbH All rights reserve No part of this manual may be reproduced in any form photocopy pressure microfilm or in another procedure without written permission or processed multiplied or spread using electronic systems All information contained in this manual was arranged with largest care and after best knowledge Nevertheless errors are to be excluded not completely For this reason see myself compelled to point out that can take over neither a warranty nor the legal responsibility or any adhesion for consequences which decrease go back to incorrect data This docum
Download Pdf Manuals
Related Search
Related Contents
Polycom Fujitsu F9600 User's Manual Widex Mind 220 CIC SERVICE MANUAL Level 1&2 User`s Manual - Pipeline Paddle Boards User`s Manual 78K0/Fx2 - CAN it! FICHA TÉCNICA DE PRODUCTO MESA Release Notes StarTech.com 4x4 VGA Matrix Video Switch Splitter with Audio Integral 2GB DDR3-1066 DIMM Copyright © All rights reserved.
Failed to retrieve file