1. 0 4 2 ESD IEC 61000 4 3 electromagnetic field immunity IEC 61000 4 4 burst IEC 61000 4 5 surge and IEC 61000 4 6 conducted disturbances man mikro elektronik gmbh n rnberg Technical Data XM50 Data Sheet 2012 04 02 BIOS MENMON Software Support Linux VxWorks QNX on request support of the FPU is currently not provided by QNX INTEGRITY Green Hills Software support available Please contact Green Hills for further information OS 9 on request For more information on supported operating system versions and drivers see Software man mikro elektronik gmbh n rnberg XM50 Data Sheet 2012 04 02 Diagram System m SDRAM DDR2 PowerPC Ethemet MPC 8548 or 10 100 1000Base Ethemet 10 100 1000Base ESMexpress MPC8543 Ethemet Only with MPC8548 Connectors PCI to USB 6 ports PCI to SATA 3 ports man mikro elektronik gmbh n rnberg XM50 Data Sheet 2012 04 02 Configuration amp Options Standard Configurations Article No CPU Type Clock System RAM SRAM FRAM Operating Temperature 15XM50 00 MPC8548 1 33 GHz 512 MB ECC 2 MB 128 KB 40 85 C Options CPU Several PowerQUICC III types with different clock frequencies MPC8548 or MPC8548E o 1 GHz 1 2 GHz 1 33 GHz or 1 5 GHz MPC8543 or MPC8543E o 800 MHz or 1 GHz Memory System RAM o 512 MB 1 GB or 2 GB o With or without ECC a SR
2. 10EMO9 60 VxWorks BSP MEN for A17 EK9 EM9 EM9A F50C F50P and XM50 Software INTEGRITY This product is designed to work under the INTEGRITY RTOS from Green Hills Software An INTEGRITY Board Support Package for this board is provided by Green Hills amp Software For more information and product support please contact Green Hills amp Software www ghs com Software Firmware BIOS MENMON is MEN s firmware BIOS for PowerPC platforms 14XM50 00 MENMON Firmware for XM50 F50C and F50P object code Software Miscellaneous A Windows USB2UART driver from FTDI is available for XM50 XM51 and F50P F50C Windows hosts More info amp downloads For operating systems not mentioned here contact MEN sales Documentation Compare Chart ESMexpress amp Embedded System ModulesDownload You can find general literature on MEN computer on modules including presentations about ESMexpress ESMini and their cooling concept in our Download Library 20XM50 ER XM50 Errata 20XM50 00 XM50 User Manual For the most up to date ordering information and direct links to other data sheets and downloads see the XM50 online data sheet under www men de man mikro elektronik gmbh n rnberg XM50 Data Sheet 2012 04 02 Contact Information Germany France USA MEN Mikro Elektronik GmbH MEN Mikro Elektronik SA MEN Micro Inc Neuwieder Strake 3 7 18 rue Ren Cassin 24 North Main Street 90411 Nu
3. AM o OMBor2 MB a FRAM o 0 KB or 128 KB 1 0 Ethernet n Only two channels instead of three with MPC8543 PCI Express links one x8 link o Reduces operation temperature range because of higher DDR SDRAM clock Software Support QNX on request support of the FPU is currently not provided by QNX OS 9 on request Please note that some of these options may only be available for large volumes Please ask our sales staff for more information man mikro elektronik gmbh n rnberg XM50 Data Sheet 2012 04 02 Ordering Information Standard XM50 Models 15XM50 00 MPC8548 1 33 GHz 512 MB DDR2 DRAM 2 MB SRAM 128 KB FRAM 40 85 C screened Related Hardware 08AE12 00 ESMexpress amp module to COM Express carrier adapter 0 60 C 08XC01 00 X Evaluation and development board for all ESMexpress amp modules coming with top cover and frame 0 60 C incl faceplate 4 GB USB Flash Disk and USB cable type A to A Miscellaneous Accessories 0712 0019 Standard ATX PSU 350 W 0 40 C Software Linux This product is designed to work under Linux See below for potentially available separate software packages from MEN 10EMO9 91 General Linux BSP for A17 EM9 EM9A EK9 F50C F50P and XM50 Software VxWorks This product is designed to work under VxWorks For details regarding supported unsupported board functions please refer to the corresponding software data sheets
4. ANSI VITA 59 in process firmware BIOS can be used for bootstrapping operating systems from disk Flash or network for hardware testing or for debugging applications without running any operating system The XM50 is screened for operation in a 40 C to 85 C conduction or convection cooled environment As all ESMexpress modules it is embedded in a covered frame This ensures EMC protection and allows efficient conductive cooling Air cooling is also possible by applying a heat sink on top of the cover Where operating temperatures are moderate the module may even do without the frame and cover with a suitable low power processor and airflow ESMexpress modules are firmly screwed to a carrier board and come with rugged industry proven connectors supporting high frequency and differential signals Only soldered components are used to withstand shock and vibration and the design is optimized for conformal coating All ESMexpress modules support a single 95x125mm form factor For evaluation and development purposes an ATX carrier board is available The EsMexpress module can be evaluated on a COM Express carrier board via an adapter from ESMexpress to COM Express man mikro elektronik gmbh n rnberg Technical Data XM50 Data Sheet 2012 04 02 CPU m PowerPC PowerQUICC Il MPC8548 MPC8548E MPC8543 or MPC8543E o 800 MHz up to 1 5 GHz o Please see Standard Configurations for available standa
5. XM50 Data Sheet 2012 04 02 XM50 ESMexpress COM with PowerPC MPC8548 The XM50 is a computer on module of the ESMexpress amp family controlled by an integrated PowerPC MPC8548 or MPC8543 CPU processor optionally with encryption unit with clock frequencies between 800 MHz and 1 5 GHz The card complies with the proposed ANSI VITA 59 standard currently under development Together with an application specific carrier board it forms a semi custom solution for industrial harsh mobile and mission critical environments The XM50 accommodates up to 2 GB of directly soldered ECC main memory and supports other memory like USB Flash on the carrier board It also features industrial FRAM and SRAM Interfaces from the MPC8548 are all routed from the XM50 for availability on any ESMexpress carrier board Those interfaces include up to three Gigabit Ethernet channels 8 PCI Express lanes for one link x4 x2 or x1 or x8 as an option triple SATA 6 USB host ports and one USB client realized using a UART to USB converter Additional COM interfaces can be made available on the carrier board via USB to COM conversion The XM50 comes with MENMON support This MPC8548 or MPC8543 up to 1 5 GHz Up to 2 GB ECC DDR2 SDRAM Up to 128 KB FRAM 2 MB SRAM 3 or 2 Gb Ethernet ports 6 USB 2 0 1 USB client 3 SATA ports 1 PCI Express x4 MENMON BIOS for PowerPC cards 40 C to 85 C Tcase screened Conduction cooling
6. rd versions o e500 PowerPC core with MMU and double precision embedded scalar and vector floating point APU o Integrated Northbridge and Southbridge Memory m 2x 32 KB L1 data and instruction cache 512 KB 256 KB L2 cache integrated in MPC8548 MPC8543 Up to 2 GB SDRAM system memory n Soldered o DDR2 with or without ECC o Up to 300 MHz memory bus frequency depending on CPU 16 MB boot Flash 2MB non volatile SRAM o With GoldCap or battery backup on the carrier board 128 KB non volatile FRAM Serial EEPROM 8 kbits for factory settings Serial ATA SATA Three ports via ESMexpress connector SATA Revision 1 x support Transfer rates up to 150 MB s 1 5 Gbit s Via PCI to SATA bridge USB Six USB 2 0 host ports via ESMexpress connector o OHCI and EHCI implementation o Data rates up to 480 Mbit s One USB client port via ESMexpress9 connector o Via UART to USB converter o Data rates up to 115 2 kbit s o 16 byte transmit receive buffer o Handshake lines none Ethernet Three 10 100 1000Base T Ethernet channels with MPC8548 E Two 10 100 1000Base T Ethernet channels with MPC8543 E Two LED signals per channel for LAN link and activity status and connection speed Accessible via ESMexpress connector PCI Express One x1 or one x2 or one x4 link via ESMexpress amp connector PCle 1 x support Data rate 250 MB s in each direction 2 5 Gbit s per lane GPIO 1 line from board controller via ESMe
7. remberg ZA de la Chatelaine Ambler PA 19002 Phone 49 911 99 33 5 0 74240 Gaillard Phone 215 542 9575 Fax 49 911 99 33 5 901 Phone 33 0 450 955 312 Fax 215 542 9577 E mail info men de Fax 33 0 450 955 211 E mail sales menmicro com www men de E mail info men france fr www menmicro com www men france fr The date of issue stated in this data sheet refers to the Technical Data only Changes in ordering information given herein do not affect the date of issue All brand or product names are trademarks or registered trademarks of their respective holders MEN is not responsible for the results of any actions taken on the basis of information in the publication nor for any error in or omission from the publication MEN expressly disclaims all and any liability and responsibility to any person whether a reader of the publication or not in respect of anything and of the consequences of anything done or omitted to be done by any such person in reliance whether wholly or partially on the whole or any part of the contents of the publication The correct function of MEN products in mission critical and life critical applications is limited to the environmental specification given for each product in the technical user manual The correct function of MEN products under extended environmental conditions is limited to the individual requirement specification and subsequent validation documents for each product for the applicable use case and has
8. to be agreed upon in writing by MEN and the customer Should the customer purchase or use MEN products for any unintended or unauthorized application the customer shall indemnify and hold MEN and its officers employees subsidiaries affiliates and distributors harmless against all claims costs damages and expenses and reasonable attorney fees arising out of directly or indirectly any claim or personal injury or death associated with such unintended or unauthorized use even if such claim alleges that MEN was negligent regarding the design or manufacture of the part In no case is MEN liable for the correct function of the technical installation where MEN products are a part of Copyright 2012 MEN Mikro Elektronik GmbH All rights reserved MEA RM R mikro elektronik gmbh n rnberg
9. xpress amp connector Usable for LED Miscellaneous Real time clock with GoldCap or battery backup on the carrier board Temperature sensor power supervision and watchdog ESMexpress Specifications n accordance with proposed standard ANSI VITA 59 RSE Rugged System On Module Express Electrical Specifications Supply voltage power consumption o 12V 9 16 V 12 W approx Mechanical Specifications Dimensions 95 mm x 125 mm conforming to ESMexpress amp specification ESMexpress PCB mounted between a frame and a cover Weight 250 g incl cover and frame Environmental Specifications Temperature range operation 40 85 C Tcase ESMexpress cover frame screened Temperature range storage 40 85 C Relative humidity operation max 9596 non condensing Relative humidity storage max 9596 non condensing Altitude 300 m to 43 000 m Shock 15 g 11 ms EN 60068 2 27 Bump 10 g 16 ms EN 60068 2 29 Vibration sinusoidal 1 g 10 Hz 150 Hz EN 60068 2 6 Conformal coating on request MTBF 209 732h 40 C according to IEC TR 62380 RDF 2000 Safety PCB manufactured with a flammability rating of 94V 0 by UL recognized manufacturers EMC EMC behavior depends on the system and housing surrounding the ESMexpress amp module MEN has performed general successful EMC tests for ESMexpressQ using the XC1 evaluation carrier according to EN 55022 radio disturbance IEC 6100