Home
Glove Lock QCP - bei Divers
Contents
1. INNOVATIVE SAFETY SOLUTIONS MADE IN SWEDEN www sitech se Important information e The different Spanner Rings included in the package allows use of We want to congratulate you on your purchase of the Glove Lock QCP a Dry Glove a great variety of seals and gloves The different Spanner Rings are system developed and manufactured by SI TECH IN Sweden By reading this manual color coded which indicates various thickness You simply choose you are only some simple steps away from diving it The Glove Lock QCP is an the thickness best fitted for your choice of seals and gloves aP easy to mount easy to use Dry Glove System designed to perform no matter e Always dive the Glove Lock QCP system with seals installed F the diving environment This complete package include components that will fit your needs undepending the choice of Dry Gloves Suit Ring Glove Ring The system itself consists of eight e Connects on Quick Cuff components per arm e User friendly e Suit Rings e Self supported e Glove Rings e Accomodating all hands E e O rings e Fits to most common Dry Gloves vor e Red green blue yellow and black e Sturdy construction Fitting alternatives 3 Spanner Rings e Glove Lock QCP Suit Ring E Quick Cuff is a Modular Quick Change Solution designed to simplify change of broken or torn e Glove Lock QCP Suit Ring E i Is on drysuits wrist seals on drysuits attachment platform 1 Suit Ring No ali
2. creases may cause leakage not hold together please change the Spanner Ring to a thicker one After you have conducted a testdive you may trim the excess material on the glove shaft for optimized function comfort and visual appearance Equalization Tube 3 1 Put your hand through the seal and fit the Equalization Tube between seal and wrist Make sure the Equalization Tube reaches all the way through the seal Bayonet www sitfech se 3 2 Join the rings together make sure that the O ring and sealing surface 5 3 are properly cleaned and lubricated 3 3 When the Glove Ring and the Suit Ring has been joined together just turn the Lock and Release Ring as the image displays Turn the Lock and Release Ring until it stops When this procedure has been made properly you should only be able to see part of the edge of the bayonet as displayed in the right section of the image box 4 1 Turn the Lock and Release ring in opposite direction compared to the donning procedure Turn until the Glove Ring and the Assembly Ring are separated Tip Keep glove on when doffing second ring The glove provide a higher friction against the rubber ring Whatever method chosen be certain the wrist seal be it latex or silicone is properly treated Always make a leakage and stress test on your drysuit seals before diving e If high resistance occurs disassemble and lubricate with SI TECH Lube Stick e f the rings are misaligne
3. Ring and O ring Spanner Ring red For extremely thin fabrics Spanner Ring green For thin fabrics Spanner Ring blue For medium fabrics Spanner Ring yellow For thick fabrics O ring Lube Stick Pressure Equalization Tube Spanner Ring black For attachment to Quick Cuff SI TECH is a Swedish company focusing on manufacturing and marketing of components for protective suits such as drysults rescue suits and garments designed for diverse hostile environments SI TECH is rooted in the diving industry which is still the company s core market The company was founded in 1971 by the diving pioneer Stig Insul n Core products Modular Quick Change Solutions Drysuit Valves Drysuit seals Dry Glove Systems Gas Inflation Systems and special compoents for military purposes Inhouse capabilities Develooment and production is made in house at our facilities in Brastad Sweden Inhouse competencies include CAD constr uction Injection Molding CNC Machining EMD Machining Assembly Sales and Marketing Logistics and Administration Our team of engineers sales and marketing personell have close co operation with the distributors and end users of our products SI TECH AB Glove Lock QCP manual Version 2 0 February 6 2013 SI TECHE INNOVATIVE SAFETY SOLUTIONS MADE IN SWEDEN www trockireparaturen de www sitech se
4. d disassemble and don again e Sand and debris caught up by lubricant on Glove Ring and or Suit Ring may cause leakage If not removed Remove O ring and make sure the O ring groove and adjoining surface on Suit Ring is clean before replacing the O ring To change or to clean and lubricate the O ring follow these simple steps Press the Lock and Release Ring backwards When Lock and Release Ring is trapped in its with your thumbs until you can access the backward position you will be able to pinch O ring NOTE Do not use excessive force as the O ring and pick it out of its groove that might break the rings NOTE Do not use any sharp tools as they may damage the O ring Lubrication IMPORTANT e Lubricate the O rings e Avoid any lubricant on seals e Clean by disassemble and rinsing all parts thoroughly in fresh water e Dry before assembly For best performance lubricate the surface marked with red Use SI TECH Lube Stick e After every dive you should check for damage or debris and clean the system with fresh water e Before every dive you may do the same check depending on how you store the system e The O ring seal and its groove is especially important to check for dirt e Store the rings apart in a debris free enviroment Our products have been trusted by divers for more fhan 40 years Item no 60523 60539 60538 60537 60536 60535 80197 60540 60233 60524 Item Suit Ring Glove Ring with Rubber
5. gnment needed 360 swiveling connection 2 Lock and Release Ring made of rubber for maximum grip protects the O ring from mud and debris 3 Glove Ring 4 Concealed O ring This manual does not address the topic of gluing attaching the Wrist Ring of the Quick Cuff to your drysuit Please visit www trockireparaturen de for information INNOVATIVE SAFETY SOLUTIONS MADE IN 1 WWW Si F e c h S e The Quick Cuff system is a Modular Quick Change Solution for rapid change of broken or torn seals It was developed and launched years before the Glove Lock QCP The Glove Lock QCP however was designed so that the user of Quick Cuff could benefit from it when choosing the Glove Lock QCP For illustrative reasons we are using a yellow Wrist Ring This is not an available product 1a 1 Find appropriate Spanner Ring and move 1a 2 Position the Spanner Ring so that the it forward through the arm of the suit towards system does not affect your wrist movement the latex seal when diving IMPORTANT Make sure that the soft rounded edge of the Spanner Ring heads forward so that the sharp edge of the opposite side does not damage the seal 1b 1 Located on the inside of the Suit Ring of 1b 2 Squeeze the soft Wrist Ring and insert it the Glove Lock QCP there is an edge that will into the Suit Ring of the Glove Lock QCP act as fixation point for the soft Wrist Ring of Expand the Wrist Ring fully and arrange so the Quick Cuff Sy
6. stem that the edges of the rings come together 1b 3 The last steps of the mounting process is same as with a regular Quick Cuff System It only differs by the fact that you need to choose the black Spanner Ring that comes with the Glove Lock QCP kit instead of the Spanner Ring delivered with the Quick Cuff kit 1a 3 Press the Suit Ring evenly onto the seal so that the seal tightens in between the rings Check for creases on the seal as creases may cause leakage 1a 4 Test the strength of attachment by pulling Always check for ceases dirt the arm of the suit and the Suit Ring in the or damaged surfaces before mounting opposite direction If the Suit Ring falls off and use of the equipment change the Spanner Ring to a thicker one Spanner Ring black HR INNOVATIVE SAFETY SOLUTIONS MADE IN SWEDEN 2 1 Start by finding appropriate Spanner 2 2 Place the Spanner Ring on the inside of the glove make sure to find proper position for optimized length of the glove 2 3 Fold the glove shaft inwards over the Spanner Ring latex gloves can be fitted and folded the opposite way Ring When pressing the Spanner Ring and glove into the Glove Ring they shall slide without use of excessive force 2 4 Press the glove with Spanner Ring 2 6 Test the strength of attachment by pulling Glove Ring and Glove in the evenly into the Glove Ring 2 5 Check for creases on the glove as opposite direction If the assembly does
Download Pdf Manuals
Related Search
Related Contents
Miele Washer W 1215 User's Manual Setup and Quick Reference Guide Detailed Specification - Don Whitley Scientific Limited 1 - VIMEC Life Fitness LIFECYCLE M051-00K39-A167 User's Manual bulletin d`informations municipales - Mairie de Chanteloup-en-Brie FRANÇAIS eMedNY Subsystem User Manual Copyright © All rights reserved.
Failed to retrieve file