1. 8 28 2 On Outputs Volume d ES Graphic r PEG Overflow Signal bk Bandwidth Frequency Level Overflow E e Adjust the PEQ parameters to suit your needs o Bandwidth Oct here you can adjust the Q factor of the PEQ either by using the slide bar arrow key or by entering directly the value in the dedicated cell o Frequency Hz here sou can adjust the central frequency of the PEQ either by using the Slide bar arrow key or by entering directly the value in the dedicated cell Oo Gain dB here you can adjust the PEQ gain either by using the slide bar arrow key or by entering directly the value in the dedicated cell o PEQ Overflow Signal indicates if there is an overflow after the addition of the PEQ to the base signal Ateis International 124 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 o Bypass All by clicking on the Bypass All button you will instantaneously bypass all three PEQ filter o Volume dB displays the real time volume on output o Level dB allows to adjust the output level either by using the slide bar arrow key or by entering directly the value in the dedicated cell o Level Overflow indicates if there is signal overflow on the base signal o Graphic by clicking on the Graphic button you will enter the PEQ graphic edition window see below You will be able to adjust gain and central frequency of each PEQ by
2. End of line Capacitor 100V Line End of line Capacitor 8 33 8 Normal Logic Inputs Normal logic input have been designed to work with simple contact or button Follow the next schematic to connect a contact to a normal logic input Ateis International 135 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS EXTERNAL FIREMAN MICROPHONE ETHERNET PORT ponte POWER SUPPLY 1 54 hd an LA G GAIN MIC LINE PSS PSM RS232 REMOTE EXT MUSIC INPUT Or Or ZONE1 ZONE2 NE ZONES ZONES NEG ZONE ZONES 8 33 9 Evacuation inputs The main aim of evacuation input is to offer the possibility of monitoring contact To achieve a monitored contact please see the schematics below To learn more about how to perform a monitorable contact please read this KTACT SG 4 i EXTERNAL FIREMAN MICROPHONE ETHERNET PORT Ditz LINK OUT MUSIC INPUT POWER SUPPLY AA Fiabe LEE LL A EA Lin ELBE LA S L i L at sjid ditd jdid DUET DURE DEE DGGE jiii Deeg GOOD FETO 0000 GOOG DOOD FITO FFT OO amp La L EE Se 1 2 GAIN WEINE PS 5PS5M RSZ32 REMOTE EXT 8 33 10 Outputs Logic output are simple contact that when closing link the OUTPUTx connector to the COM connector The following schematic show a way to create a indicator LED Ateis International 136 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS EXTERNAL FIREMAN
3. MICYLINE PSS PSM Third Farty Control Audio Ch l Wee FO Channels dE Line ge GER Loo Link Sain Audio to Amplifier Inputs lg P Main Power Logical and Fault toute EJ45 Connector to oupply Peupen Connector Ateis International Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 2 3 DIVA8S Front view Power Indicator LED Ateis International Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS Zone Event Indicator LEDs Zone Selection Buttons 13 ATEIS 2 4 DIVA8S Rear view Network Logic Inputs and Monitored Losic Connectors External fault Inputs Inputs Speaker Zone Outputs 100W Line Inputs and Main Power Supply Outputs Connector Ate s International 14 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 3 Software As briefly mentioned in the Installation paragraph DIVA8M package hold a CD Rom The CD contain the DIVA8M Quick Start Manual pdf User Manual Microsoft HTML Help Executable chm HTML htm and DIVA software It could happen that the software on the CD Rom is not the last release In that case please visit ATEIS website to download the latest release and follow the steps described in the Software Installation Process 3 1 Installation Process e Insert the CD Rom in your computer e Double Click on the My Computer on the desktop Open the CD ROM submenu e Double Click
4. 16 CG ATEIS DIVA v1 0 0 beta 6 InstallShield Wizard The wizard is ready to begin installation Ready to Install the Program gt A TF you want to review or change any of your installation settings click Back Click Cancel to exit the wizard Current Settings Setup Type Typical Destination Folder C Program Files ATEISIATEIS DIYA v1 0 0 bebaty User Information Name Ate International Company Ateis InstallShield tal To finish the Installation process just click Finish CG ATEIS DIVA vi 0 0 beta 6 InstallShield Wizard InstallShield Wizard Completed The InstallShield Wizard has successfully installed ATEIS DIYA 1 0 0 betat t Click Finish to exit the wizard Finish Cancel The installation process will automatically create a Desktop Icon like the one under ATES DIYA 1 0 0 betal10i Ateis International 17 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 3 2 Uninstall To uninstall a current version of the DIVA software please follow the next few steps Click on start gt Program gt ATEIS gt DIVA gt ATEIS DIVA v1 0 0 Uninstall Windows Installer will ask you if you are really sure to remove this program click Yes 3 3 Software Upgrade In case of a new release of the DIVA software Please go to the ATEIS website in order to download the last software version Before installing the new software please uninstall the curre
5. Ateis International 64 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 8 18 3 Event Type In the Next paragraph you will fin a description of all the different event that could be found in DIVA programming You will by this way learn how to use them and when to use them Load Preset Logic Output Command String Stop Event Stop Zone Play Message Fireman Mic Paging MIC LINE Paging Music ON Music OFF Music ON By Zones Music OFF By Zones Toggle Music ON OFF Toggle Music ON OFF By Zones Security Mode Stop All Events 8 18 3 1 Load Preset In DIVA you have the possibility to set preset To learn more about presets please read this The event load preset can be used as soon as there are existing preset Load Preset Event Type Load Preset Priority Not Accessible Name Event 3 Attrib Security i Next Event Preset Type displays the type of event that is created in this case Load Preset Name here you can specify a name for the event created Attrib here you can choose between security event or not See Common Option to learn more about the security option e Next Event you can specify an event that will be started as soon as this event has finished Ateis International 65 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS e Preset here you can specify the preset to be loaded 8 18 3 2 Logic Output As described before DIVA
6. To learn more about the Logic inputs see How to Use Logic Inputs The idea is to use logical trigger to start an event Event type for operation on Mic Line are listed below You can find more information on those events in the chapter How To Use Events e Mic Line Paging Event In order to associate a event to a logic input trigger click on the Start button under Event Setting The Events Selection window will be open see below Ateis International 103 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 Events Selection Select Event List Name Priority Type Security Name Priority Type Security Event Select All Select All hift U weg EH s Insert Delete Select Hone Select Hone d Shift Down On the left side you will find the list of existing event To create a new event simply click on New under Event As soon as you click on the New button the software will ask to choose a event s type see below Master Select Master 1 Event Type Music On In order to select the event s type use the drop down menu Then click OK After you have press OK you will return to the Events Selection window To edit your new event settings select it by clicking on the right line and then click Edit Note don t click in the square selector The corresponding event s type window will pop up After your event settings are complete click OK The last step is to affiliate the eve
7. Type Play Message Priority FE Zero equals highest Event 1 Attrib Security Next Event Active at Start _ Active at Stop Logic Output Mone selected Channel Length ms Enable ACK Relay Enable Busy Relay Master Master Logic Output None selected Logic Output None selected Channel Channel Message i Play Mode Continuous Conflict e Cancel All Coexist Repeat Times Master 1 Masher Type display the type of event you are creating or modifying Name here you can specify a name for the event created Default is Event X Priority here you can adjust the priority of the event 20 is the lowest 0 is the highest Attrib here you can specify if this event is a security one or not See Common Option to learn more about the security option e Next Event here you can select the event to start after the current on is finished e Active at Start Ticking this option allows user to close an output contact Logic Output channel in two different manner Static will close it until the event stop and Pulse will generate a closing pulse whose length can be defined from 50 to 60000 ms Ateis International 69 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS A e Active at Stop This option is used to create a closing contact pulse when the event is finished The length of the pulse can be defined from 50 to 60000 ms e Enable ACK Relay here you can set the clo
8. permanent task will happen every hour day week month or year from the date and hour selected Number of times task will happen for a certain number of hour day week month or year from the date and hour selected Example if set every day then 3 number of times the task will happen the first day set and the two next day at the same hour Period task will happen each hour day week month or year for a certain period can be several hours days weeks etc For this option you will have to specify an end time o Select a month day and hour as described above o Press OK Ateis International 115 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 Scheduler Task Name Scheduler Task 1 Enable w Enable Trigger Event Uccunrence Single Repeat Every fear e Permanent Number of Times Period Start Time 4 julet2008 rt 1243456 MH 910111213 141516171819 20 21 22 23 24 25 26 27 28 29 30 31 juillet 2006 12346566 8 910111213 14151617 18 19 20 21 22 23 24 25 26 27 28 29 30 31 o Your task will be displayed as follow in the scheduler window Scheduler Master M aster 1 Oecurence Name Enable Target Ha i Test la H mi e ETS ESCH 8 27 Use Filters Weekly 2008 OF OST 240 Not Select On DIVA you can add hi pass or low pass filtering on audio input and on amplifier outputs in order to adjust th
9. 10 dB the music source activation will take place when the signal received from that source will be over 10 dB e Attack Time ms The Attack time can be understood like the amount of time that the signal have to be over the threshold point before music source will be activated A correct setting of the attack time can avoid inopportune activation of the music source peak signal activation The Attack time can be set from 0 ms to 5000 ms e Release Time ms As opposed to the Attack time the Release time is the amount of time for which the signal have to stay under the threshold point before deactivation of the music sources A correct Release Time can avoid inopportune deactivation of the music source blank in CD The release time can be set from 0 ms to 5000 ms Setting those parameter correctly needs some experience so be careful and please test it to learn more about the behaviour of this option Once your modulation detection parameters are adjusted you have to edit the advance setting for the music sources please refer to the Use Music Source general chapter 8 21 3 In Permanent Mode In Permanent mode the music sources are set once and cannot be manage anymore from front panel However real time controls are still useable To change the sources routing you will have to change the DIVA configuration In permanent mode you only have to Edit the music sources parameters see this Note be carful when setting priorit
10. Edit Us Close Fireman Mic Paging Master here you can select which master events list you wan to work on e Square Selector you can select event s by ticking the square selector at their right ID Name displays the event s name You can specify a name for an event when editing the event By default the name is set to Event X Priority displays the priority level of an event Security displays if the event is a security one or not Type displays the type of the event Next Event displays which event is called after this event Time if an event loop have been created displays the number of time the loop is made Link By displays the previous event in the sequence or loop Select All select instantaneously all events in the list Select None deselect instantaneously all selected events Delete delete selected event from the list Event Type here you can select the event type that you want to create This have to be made before press the Add button Add after the event type selection pressing the Add button will create the new event in the list Edit after creating an event you will have to edit all its parameters By clicking the edit button you will enter the different event setting windows e Close closes the Event window There are different type of event and here is a list of all event that can be created Note some event created by accessing the music fireman microphone and MIC LINE windows are automatically n
11. If not already log in DIVA will ask you to enter a valid username and password to be able to modify Ethernet parameters Use the arrow keys to access the Ethernet Setting menu Press OK twice Choose between DHCP enable or disable Enable DHCP means that the IP configuration will be automatically set by your network be careful when using this option In most of the case you will have to enter manually your network prameters to achieve this choose disable Press OK Enter the IP address value using arrow keys and keys to change the IP address value Default address is 192 168 100 1000 Press OK Enter the Submask value using arrow keys and keys to change the IP address value Default Submask is 255 255 255 0 Press OK Enter the Gateway value using arrow keys and keys to change the IP address value Default Gateway is 192 168 100 1 Press OK You will be prompt Are you sure Press OK if yes or no if not 6 1 11 Music 1 Level You can adjust the level of the music source 1 Use arrow keys to access the Speaker Level menu Press OK Adjust the level with the or arrow keys Press ESC to go out of the menu 6 1 12 Music 2 Level You can adjust the level of the music source 2 Use arrow keys to access the Speaker Level menu Press OK Adjust the level with the or arrow keys Press ESC to go out of the menu 6 1 13 Get Reference From the front panel menu you can get monitoring references by accessing the
12. moving the yellow cursor Bandwidth is controlled by the orange cursor P Music Amp 8 29 Use Compressor Limiter In DIVA software you can add for each audio input a compressor a limiter or a combination of both limiter and compressor in order to do so please follow the next few steps e Inthe Master window double click on the DIVA icon The DSP configuration window will pop up Note if no audio sources have been set into the configuration the corresponding Filter and Compressor Limiter location will be grayed e Drag and Drop from the Design Component Section either Compressor limiter or compressor limiter to the right location Compressor Limiter is a component that is either a compressor or a limiter Compressor Limiter is a component that offers both compression and limitation o The DSP configuration windows should look like follow Ateis International 125 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 l Master 1 DSP Configuration e Mote Drag Audio components here Compressor Limiter Filters Comp Limiter Bypass Music PEG Mixer Voice Channel MIC Line Bypass Bypass Tone Priority Generator Fireman MIC Bypass Bypass Management FEQ Miner PSS Bypass Bypass Music Channel e Double click on the compressor limiter icon the compressor limiter window pops up see below Adjust the Compressor Limit
13. A e The first PEQ filter can be changed to a High pass filter with the corresponding drop down menu see below e The last PEQ filter can be changed to a Low Pass filter with the corresponding drop down menu see below 1 4 2 3 4 5 E 7 volume Graphic el ei es F z x F FE Overflow Signal Bandwidth 9 Oct Up SLP TTT tl Hz Le Level dE il Frequency KL NZ Gain dB I d e For the low pass and high pass filter you have access to the following settings cutoff frequency and gain e By clicking on the Graphic button you will able to adjust the cutoff frequency and the gain directly by moving the corresponding yellow cursor see below Voice Amp TEEN 10 125 16 20 25 31 5 40 50 63 60 100 125 160 200 250 315 400 500 630 800 1K1 25K1 6K 26 2 563 156 4K 5K BSE BE TOKI2Z 5 1BE 206 25k L Le Ate s International 120 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS 8 28 Use PEQs On both output channels and input sources you can add peaking equalization You can add a three band PEQ on inputs and use up to seven bands PEQ on amplifier outputs To access the PEQ on inputs go on the DSP configuration window Master 1 DSP Configuration Note Drag Audio components here Compressor Limiter Filters Bypass Bypass Bypass Byp
14. Access Control Address This number act like a name for one particular network device This cannot be change To see the MAC address just follow this steps e Use the arrow keys to access the MAC ADRESS menu e click OK the MAC Address number is display e Press ESC to go out of the menu The MAC address value s can be changed please change the MAC address only if it s needed Use the arrow keys to access the MAC ADRESS menu click OK the MAC Address number is display Use Arrow Key to go on the number to change Us key to change the number s value Press OK to accept the changes you will be prompt to validate the changes Press OK if you accept the changes In the world of computer networking there is one common way to set an quasi unique identifier to a network device This is the MAC address Media Access Control Address This number act like a name for one particular network device This cannot be change To see the MAC address just follow this steps e Use the arrow keys to access the MAC ADRESS menu e click OK the MAC Address number is display e Press ESC to go out of the menu The MAC address value s can be changed please change the MAC address only if it s needed Use the arrow keys to access the MAC ADRESS menu click OK the MAC Address number is display Use Arrow Key to go on the number to change Us key to change the number s value Press OK to accept the changes you will be prompt to validate the changes P
15. Cancel Al Coexist Pre Chime Pre Chime Enable Pre define one Pre detine one Enable Master 1 All Master alfa f2 3 as 6 78 Type display the type of event you are creating or modifying Name here you can specify a name for the event created Default is Event X Priority here you can adjust the priority of the event 20 is the lowest 0 is the highest Attrib here you can specify if this event is a security one or not See Common Option to learn more about the security option e Next Event here you can select the event to start after the current on is finished e Active at Start Ticking this option allows user to close an output contact Logic Output channel in two different manner Static will close it until the event stop and Pulse will generate a closing pulse whose length can be defined from 50 to 60000 ms e Active at Stop This option is used to create a closing contact pulse when the event is finished The length of the pulse can be defined from 50 to 60000 ms Ateis International 71 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS _ sae Enable ACK Relay here you can set the closing of a Logic Output Channel relay as soon as zones where an event has to be played are freed from higher priority events Enable Busy Relay here you can specify an Logic Output Channel relay that will be closed as soon as you will trying to speak in zones where a higher priority event current
16. Connection to previous JB or LAP bus on the first JB RS485 SIDE for URC connection Easy connection to a Master PPM using the supplied 10 pins cable Connection to first Slave PPM Slave features are not available for the moment MAIN OUT connection to next JB 20 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS A e 2 internal screw connectors for 0 dB audio e audio output from PPM microphone gt Audio Output connect to the Audio In of the LAP e audio input to PPM speaker gt Audio Input connect to the Audio Output of the LAP if needed e 1 input for additional 24V power supply Depending on distance between LAP and PPM URC you will have to put an external powe supplyr e 1 internal switch for PPM Master or Slave selection Slave features are not available for the moment e 1 internal switch for System or Local power supply selection Ateis International 21 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS 5 DIVA Philosophy Before going any further the philosophy of DIVA have to be exposed This chapter will be split in three parts e Front Panel e Software e Events 5 1 Front Panel The DIVA front panel have been made for basic controls operation as well as to define basic settings Some features of the front can be disabled in case of advanced configuration The Front Panel is designed to start three different messages toggle betwe
17. D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 Input Select Default Source 8 21 6 Software Control e Logic Input e Logic Input Ss Normal Input Channel 1 Normal Input Channel 2 Music OFF Music ON The DIVA software allows to control and monitor music sources Once you have enter the music source window by double clicking on the music source icon you will be able to read and control some parameters right part of the window see below Music 1 and 2 level controls Music 1 and 2 mute controls Music Source Music Advanced Settings Activation Mode e Modulation Detection Threshold dB Attack Time ms Release Time ms _ Permanent Loge Input Input Select H a Route Ken Default SOUICE Music 1 e Ateis International Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 Music 1 and 2 overflow indicators Music 1 and 2 signal presence indicators Music 1 and 2 volume indicators l Music Musica Permanent Logic Input ATEIS A 8 22 Use PSS Microphone As described briefly in the External Device PSS chapter the PSS microphone is an advance touchscreen paging microphone The PSS touches Keys can be set by the user using the PSS window in DIVA software In order to use a PSS microphone with DIVA simply drag and drop the PSS microphone from the Design Component Se
18. Fireman Microphone In order to use the fireman microphone first drag and drop the fireman microphone from the Design Component Section to the Master window Double click the fireman microphone icon to enter the Fireman Microphone window see below Master 1 Note Drag Audio Sources here BAR Speaker Parameters Setting Machine PSS Music 1 Enable Voice Amp Ge e Monitoring Music 2 Enable D ws Mic Line Enable Message Enable Music Amp Here is a list of controls and indicator in the fireman microphone window e Advance Setting by clicking the Edit button you will enter the fireman microphone event setting window Please see below Note the fireman microphone paging mode is always push to talk By default the priority of the fireman microphone is set to zero the highest priority available and the security event is ticked The Ateis International Q3 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS eis fireman microphone have been designed to be an emergency paging element so be careful when changing priority and security settings e Level dB When connected to DIVA you can adjust real time mode the level of the fireman microphone e Volume dB Indicates the current output level of the fireman microphone Level Overflow This is a LED indicators that light up when a too high level is detected on the fireman microphone e Zone Release Time here you
19. International 130 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS According to the FigAnnexe 2 you have a fully monitored line responding to the security norms 8 33 Wire Things In this chapter you will find schematics about how to wire DIVA with external devices Here is the list of devices that will be discussed Power Supply Fireman Microphone PSS Microphone Music Sources Mic Line Amplifier Speaker lines Normal Logic Inputs Evacuation Inputs Outputs 100V Output Computer RS232 DIVA8S Basic Wiring Remote Panel 8 33 1 Power Supply The DIVA operating voltage supply is 24VDC Pleas use only the provided power block or something equivalent To connect the provided 230V 24VDC power supply use an euroblock connector in order to link the power supply to the 24VDC and OV DIVA inputs EXTERNAL FIREMAN MICROPHONE ETHERNET PORT i G Ke e 2 4 A VOICE AMP MUSIC AMP MUSIC INPUT a T L L RO Or ZONE4 ZONES ZONES ZONE7 1 2 GAIN MIC LINE PSS PSM RS232 REMOTE EXT In case of using an other supply watch out for polarity and voltage value Ateis International 131 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS 8 33 2 Fireman Microphone To connect the SHM1 fireman microphone simply connect the SHM1 connector with the front panel fireman microphone connector In case of using an other microphone use the back connector to connec
20. International 62 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 According to the looping event diagram when selecting next event for Event 2 choose Event 1 As soon as you select a event that is before in the chain a new Circular Times selector is visible just beside the next event drop down menu see below This selector permits to define how many time the events loop will be repeat or to make it continuously repeating This is a quick way to loop different language evacuation messages for example Ateis International 63 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 Se Nest Event Event 1 Circular Mode Continuous Circular Times 3 a Once you go back in the event window You can see multiple information about sequences like the next event that is called Next event the number of time the loop is repeated Times and the event or action that is linked to one event Link By see picture below MISE Master Master 1 e EE e a e E 1 Es rl ren SES BR Play Message EE e Wi IESE Event 2 m T Den Message Event 3 alt Event Event 1 e S ER Event 3 5 L lay Message Event 1 Event Event 2 Delete ss A b i Le Close Select All Event Type By clicking at the right of the Next Event box you will be able to graphicaly display the event sequence or loop see below Next Event Event 1 Event 3
21. Microphone Use Music Source Use PSS Microphone Use Mic Line Input Use Logic Inputs Use Monitoring Use the Scheduler Use filters Use PEQs Use Compressor Limiter Use Preset Use Output Relay Create a Monitorable Button Wire things Use Tone Generator Note Some topics could be divided in sub topics as the procedure could induce multiple procedure to achieve the main goal 8 1 Save Open The Save Open procedure is quite identical to most of the Microsoft Windows based software The icon used as well as keyboard shortcuts are well known for Microsoft Windows users Ateis International 4 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 Here you will find procedures to e Open afile e Save afile e Save afile as e Set an Autosave process 8 1 1 Open Open a DIVA file Click on the Open Icon Highlighted in picture below in the Edit toolbar or go to menu File gt Open or even press Cir o SP ella ah ae ee eee 8 1 2 Save Save a DIVA file Click on the Save Icon Highlighted in picture below in the Edit toolbar or go to menu File gt Save or even press ctr s LA IAE h oa The first time you will be saving a project you will be prompt to enter a name for that file The Save command is used to save current project under the current name Note DIVA s configuration files are saved in diva extension 8 1 3 Save as The Save As option can be used to save a configura
22. PORT A LINK OUT OUPUTS 100Vout VOICE AMP MUSIC AMP MUSIC INPUT dune vis t t t t sdg dits d Si84 S384 F382 died sos e g Z Z Z zz Z Z Z SZ Z ZZ FA zz z zz ZZZ i S A AE 0000 0000 0000 0000 0000 0000 0000 0000 60600 Sa K Gin L Jaen L 1 Ger GAIN MIC LINE PSS PSM RS232 REMOTE EXT oO E 0000 est IS a 8 33 5 Mic Line The MIC Line input can be used as a microphone input or as a third music input According to the schematics below use an standard XLR cable to link the microphone to DIVA or connect the Left Right channel of a music source to XLR connector of DIVA Note gain must be adjusted in case of using microphone or a music source Ateis International 133 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ZONE1 ZONE2 ZONE ZON es OO OC FO OC _ OC E agaa ZONE1 ZONE2 ZONE3 ZONE4 ZONES ZONES 8 33 6 Amplifier EXTERNAL FIREMAN MICROPHONE MUSIC INPUT d Or EXTERNAL FIREMAN MICROPHONE MUSIC INPUT Or Or Co ATEIS ETHERNET PORT LINK OUT POWER SUPPLY x ha oco Or GAIN MICILINE PSS PSM RS232 REMOTE EXT ETHERNET PORT LINK OUT POWER SUPPLY F LA aen LA DER Lesch GAIN MIC INE PSS PSM RS232 REMOTE EXT The connection to amplifier can slightly change according to the amplifier model used The OdB output of DIVA are named as follow e AIN for positiv OdB output e A
23. Phone 41 21 881 25 10 ATEIS DIYA System Ga Master Audio Source Fireman Microphone lp PSS Q Music Microphone au Line In Audio Component y Filter Compressor Limiter Compressor j Limiter Compressor Limiter e DIVA System In the DIVA System folder you will find DIVA Master unit icon See How to Add Design Component e Audio source In Audio Source folder you will find audio elements that can be connected to a master DIVA unit gt Fireman Microphone see How to use a Fireman Microphone gt PSS see How to Use PSS Microphone gt Music see How to Use Music Source gt Microphone see How to Use MIC LINE Input gt Line In see How to Use MIC LINE Input e Audio Component Audio Component contains high low pass filters PEQ equalizer and compressor limiter components gt Hi Lo Pass see How to Use Filters gt PEQ see How to Use PEQs gt Compressor Limiter see How to Use Compressor Limiter gt Compressor Limiter see How to Use Compressor Limiter Ateis International 38 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS 7 6 Design View Area In this area you will e Develop your DIVA configuration see the How To chapter and DIVA master network see How to perform a DIVA master Network e Access the monitor window see How to Use Monitoring e Access to DIVA element and their adjustments DIVA Untitled diva File Edit View User Operation To
24. about output relay please read the How To Use Output Relay Conflict you can choose between Cancel All or Coexist Pre Chime Before a call you can add a chime message Here if Pre Chime Enable is selected you can select which message will be used as pre chime e Pre define Zone if ticked you can choose pre defined zone with the zone selector e Zone Selection here you can specify the zone s where the call will be played 8 23 1 With Modulation Detection The modulation detection mode allows to automatically route the Mic Line source in case of signal presence The behaviour is the same that for music sources Modulation D tection Threshold D dB Attack Time 1000 m Release Time 1000 m In order to use the modulation detection tick the Modulation Detection option for the source you want to use that way Once the option selected you will have access to detection settings e Threshold dB The threshold setting will set the trigger point for activation of the Mic Line source If the threshold is set to 10 dB the Mic Line source activation will take place when the signal received from that source will be over 10 dB e Attack Time ms The Attack time can be understood like the amount of time that the signal have to be over the threshold point before music source will be activated A correct setting of the attack time can avoid inopportune activation of the Mic Line source peak signal activation The Atta
25. has 8 output channels that can be commanded by several trigger type When using the Logic Output Event you can associate to a trigger the closing of an output Logic Output Event Type Logic Output Priority Not Accessible Mame Event 4 Attrib Security Next Event None Active at Start Active at Stop Logic Output Logic Output Channel Channel Let Length Channel 1 Channel 2 Channel 3 Logic Output Geer Channel 6 Channel 7 Channel Type displays the type of event that is created in this case Load Preset Name here you can specify a name for the event created Attrib here you can choose between security event or not See Common Option to learn more about the security option e Next Event you can specify an event that will be started as soon as this event has finished e Active at Start Ticking this option allows user to close an output contact Logic Output channel in two different manner Static will close it until the event stop and Pulse will generate a closing pulse whose length can be defined from 50 to 60000 ms e Active at Stop This option is used to create a closing contact pulse when the event is finished The length of the pulse can be defined from 50 to 60000 ms To learn more about output relay please read the How To Use Output Relay e Logic Output here you can specify which output s you want to close when a trigger has been detected Ateis International 66 Ch du D vent 1024 Ecublen
26. manage conflict when two events use a common zone The higher priority event always overwrite the lowest priority event in the common zone But regarding to the option chosen the behaviour is different To learn more please read this Ateis International 61 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS 8 18 2 Event Sequence You can define multiple events by accessing the event window menu View gt Event In this window all the existing event are listed You can add delete events Before adding a new event choose in the Event Type drop down menu the desire event s type Click on the new event then Edit to be able to set up parameters for this new event You can declare event with the same action like playing a message even playing the same message You just have to give them different names The event can be cascaded An explanation diagram is visible on the next figure EVENT EVENT 3 An action like closing a contact could induce to start an event But the first event as soon as it will be finished or stopped could launch an other event The second event could activate the start of a third event and so on In each event edit page there is a next event drop down menu see below In this menu you will be able to choose between all the existing events Next Event None K Events could also be looped The diagram on figure below explains it visually Ateis
27. of a Logic Output Channel relay as soon as zones where an event has to be played are freed from higher priority events e Enable Busy Relay here you can specify an Logic Output Channel relay that will be closed as soon as you will trying to speak in zones where a higher priority event currently playing 8 32 Create a Monitorable Button The surveillance of a contact line a microphone line or speaker line is based on the same measurement An internal voltage source is applied to the input or output terminal By measuring this tension it is possible to know the state of the input or output With a normal contact see picture below you only will be able to measure two states Open or Shorten Shorten when contact is closed forces the voltage source to zero DIVA Measurement Unit EVAC1 4 4V Voltage Contact Source Button E OV EVAC1 FigAnnexe 1 In this case the measurement unit can only detect OV closed or 4 4 V opened In order to have different state measurement like open line and short circuit we need to add a resistor network to the end of the line see picture below DIVA Measurement Unit EVAC1 R 4k7 4 AN WS Voltage 1 d Contact Source oe S Button OV EVAC1 FigAnnexe 2 Using the resistor Network the measurement unit can detect 4 different states 1 3 V 2 V 2 7 V and 4 4 V The 4 states correspond respectively to Shortcut Closed Contact Opened contact and Absent open line Ateis
28. on the DIVA software icon EM ATEIS DIYA vi DI The DIVA installshield wizard will prompt Please follow the install instruction that are displayed CG ATEIS DIVA vi 0 0 beta 6 InstallShield Wizard Welcome to the InstallShield Wizard for ATEIS DIVA v1 0 0 beta 6 The InstallShield R Wizard will install ATEIS DIYA 1 0 0 b tat on your computer To continue click Next WARNING This program is protected by copyright law and international treaties Change the User Name and the Organization s name at your convenience Ateis International 15 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 CG ATEIS DIVA v1 0 0 beta 6 InstallShield Wizard Customer Information Please enter your information User Name Meis International Organization teis Install this application For Anyone who uses this computer all users Only for me Ateis International InstallShield Choose an installation folder by default it will be install in C Program Files CG ATEIS DIVA v1 0 0 beta 6 InstallShield Wizard Destination Folder Click Next to install to this Folder or click Change to install to a diff rent folder GC Install ATEIS DIYA 1 0 0 be tal to C Program Files ATEISIATEIS DIYA v1 0 0 b tal n InstallShield Then launch the installation process by clicking Install Ateis International Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10
29. option e Next Event here you can select the event to start after the current on is finished 8 19Set up Front Panel Messages There are three message button on the front panel Evacuation Alarm and Test In order to assign play message events to those buttons follow the next steps Access the front panel setup window by clicking on the Front Panel Setup button in the master page see below Front Panel Setup Evert Button ES ER NamePlay Message New Edit Evac None New Edit Alert Hone New Edit Test Hone New Edit All Call Range Setting At the left of the window you will find the button name You can set an event for only one button two or all e Inthe corresponding line click on New to assign a new play message event to the button Event created is by default named Event X e Click the Edit button of the corresponding line to enter the play message event window see below Ateis International 81 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 Play Message Event IER Play Message Event 1 Next Event Active at Start Logic Output None selected Channel fe Static Enable ACK Relay Master Slave Logic Output Mone selected Channel Priority FE ero equals highest Attrib Security Active at Stop Logic Output Mone selected Channel l Enable Busy Relay Logic Output None selected Channel Conflict e Cancel All
30. please refer to the How To Set IP Address paragraph 8 6 Use the User Management To access the user management window go on the menu User gt User Management User Management See AccountName Level lt Mo data to display de Add Edt Select All Delete Select Hone Ateis International 47 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS ee The picture above shows the main page of the user manager In this page you will be able to add new user account delete account and modify account settings The list below explains how the button works Add allows to add new user account Edit allows to edit existing account parameters Select All can instantaneously select all the existing account Select none instantaneously unselect the previously selected account Delete allows to delete accounts Close closes the User Management window 8 6 1 Add User Account To add a new user account simply click on the add button A New Account pop up window like the one below will appear New Account L 5 EN Please enter user account name Press Next to continue Cancel Enter the user name for the new account Click next New Account Lef EN Please enter account password fo Please enter again Press Next to continue Press Back to go back to previous step e Enter a password for the account created e Confirm password e Click Next to continue
31. security one or not See Common Option to learn e Next Event here you can select the event to start after the current on is finished Ateis International Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 74 e Active at Start Ticking this option allows user to close an output contact Logic Output channel in two different manner Static will close it until the event stop and Pulse will generate a closing pulse whose length can be defined from 50 to 60000 ms e Active at Stop This option is used to create a closing contact pulse when the event is finished The length of the pulse can be defined from 50 to 60000 ms e Enable ACK Relay here you can set the closing of a Logic Output Channel relay as soon as zones where an event has to be played are freed from higher priority events e Enable Busy Relay here you can specify an Logic Output Channel relay that will be closed as soon as you will trying to speak in zones where a higher priority event currently playing To learn more about output relay please read the How To Use Output Relay e Conflict you can choose between Cancel All or Coexist e Pre Chime Before a call you can add a chime message Here if Pre Chime Enable is selected you can select which message will be used as pre chime e Pre define Zone if ticked you can choose pre defined zone with the zone selector e Zone Selection here you can specify the zone s where the call will be played 8 1
32. send the print request Print Setting Button in order to set your printer parameters Master Drop Down Menu here you can change the DIVA master unit Items Drop Down Menu Here you can select which window have to be print choose between System configuration Master Configuration and DSP Configuration 8 3 Start a New Project In order to start a new project go to the menu File gt New or click on the New shortcut on the edit toolbar see below or even type ctrl n en DU el mh m xio a After launching a new project the DIVA software start a new system window looking like the one on the picture below Ate s International 44 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 Preset system System qx i 10 DIVA System H Audio Source Audio Component Seles Note Drag DIVA devices here Master 1 Un Connection Fault B Evac 0 Modified Not compiled er au igi Once the new project is started you will need to set up the network otpion as well as the correct IP adress see How To Configure Network Option and How To Set IP Address By double clicking the DIVA icon you will enter the master window page see below Hote Drag Audio SOUrces here Speaker Parameters Setting Machine Music 1 Enable LI Front Panel WT Setup Keren le Message Enable D busie Ampe In the Master window you will b
33. system with 1 master and 2 slave units using the same amplifier The second schematic shows how to perform a DIVA system with two additional amplifiers On both schematics the OdB line are displayed in black and 100V line in red Note connection are not fully described example OdB line is described as one wire instead of 3 MASTER 1 SPA2120 2x120W pe SPA2120 2x120W SPA2120 2x120W SLAVE 5 Ateis International 139 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 8 33 15 Remote Panel COMING SOON 8 33 16 Basic Wiring This schematics intends to show how to create a simple wiring for one DIVA master unit MUSIC LOCAL MUSIC LEVEL FIREMAN MICROPHONE 22 BBD sadzi EE Lasel Css jjj jagg jjo jjge RE Control Computer LineA Zone 1 Zone 2 Zone 3 i Zone 4 LineB Zone 1 i Zone 2 Zone 3 Zone 4 TUNER 0 Lac E E eg 558 a Batt Batt 88 88 CD 3588 8 34Use Tone Generator In the DIVA sof
34. the buttons that are used for managing music sources routing are the following e Route validates the music source and zone s selection e Select toggles between Source 1 Source 2 and none Ateis International g7 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS e Zone Selector allows to select each zone one by one or a group of zones e All Call instantaneously select all zone e Attenuator sets an attenuation for a zone To assigned a music source to a zone please follow the next steps e Select zone s where you want to route music e With the select button choose which music source will be routed to the selected zone s e Press the Route button in order to validate the selections Note You can independently route music source 1 and music source 2 To disable music in zone s Oo Select zone s O With the select button choose none no Source LED are lit o Press the Route button to validate selections ATEIS wae e A A O FAUT DISPLAY R E ga SS EVAL J FIREMAN 6 IC gt Cum 1 O 3 4 MICROPHONE st pan o IC 1 aam Ge SE ui 4 a Z S o ol gt DA N WW 4 e Z TEST MESSAG e aa LOCAL MU
35. the process of creating an account e Click Back to go back to the previous step Ateis International AS Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 New Account Please select the level of authority Level 4 e Level 1 is the hightest level Press Next to continue Press Back to go back to previous step Cancel e Select an Level for this user account explanation on user level can be found here e Click Finish to finish the process e Click Back to go back to the previous step 8 6 2 Delete User Account AccoutName Level ae Add me Delete Select Hone e Select an account in the list of the User Management e Click on delete e it will prompt you Delete User account click OK to delete or Cancel if stop the delete process 8 6 3 Explanation on User Level In order to comply to the European standard EN 54 16 the user level have been set as described e Level 1 is the lowest level Ateis International Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 49 ATEIS O on Level 1 has the right to use real time software control music level filters and PEQ real time front panel control music level speaker level and indicators Level 1 is always accessible without password Can do reverse procedure and connect from software e Level 2 is defined to be for person having a specific responsibility for safety Level 2 has all right e
36. this parameter will have no action if the filter type is set as limiter o Ratio Limiter x 1 here you can specify the limiter ratio either by using the slide bar arrow key or by entering directly the value in the dedicated cell Note this parameter will have no action if the filter type is set as compressor o Threshold dB here you can specify the threshold level from where the limiter or compressor will start acting o Threshold range dB here you can specify the range of level in which the ratio gradually alters from 1 1 to the value set by the ratio parameter soft knee function either by using the slide bar arrow key or by entering directly the value in the dedicated cell Response time 10ms here you specify the attack time for the compressor limiter Recovery time 10ms here you can specify the release time for the compressor Limiter Gain reduction dB indicates the current amount of gain reduction Graphic by clicking on the graphic button this will open the Compressor Limiter graphic edition window see below You can adjust the limitation ratio by moving the red cursor the limiter threshold level and compression ratio by moving the upper blue cursor and the limiter threshold range with the upper yellow cursor You can adjust the compressor threshold level by moving the lower blue cursor and the compressor threshold range with the lower yellow cursor OOOO Ate s International 128 Ch du D vent 1024 Ecublens Switzerla
37. valid user name and password and will remember your username and password until you exit or logout of the current configuration file Ateis International 50 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS To log out go to the menu User gt Logout 8 8 Update Diva The update command allow user to upgrade the DIVA internal software to the version delivered by the Windows based software This is one of the first things to do when starting a new project or using a DIVA unit for the first time This could really save time and avoid communication and store problem To activate this command go the menu Tools gt Update The Update window look like the one below File C Program Files ATEISNATEIS DIVA v1 0 0 betafel meu update CH oe e Open Here you can specify the path of the mcu update file By default the path specified correspond to the software release version e Update will start the update process e Close closes the window A timeline display shows the update process progression Once clicked on update DIVA will prompt you to enter a valid user name and password This will happen the first time you want to update if you are not already log in 8 9 Compile Compiling your current project will inform you in case of configuration errors or warnings In order to be able to store a configuration into DIVA you will have to compile your project first To compile go in the menu O
38. 024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS A e Message 1 to Message 4 with the use of the drop down menu you can add to the PSS up to 4 event buttons that will launch the corresponding selected events Please only use Play Message type of event for that application Monitoring Pre Amp virtual LED that will light up in case of PSS microphone pre amplifier failure SPK Cable virtual LED that will light up in case of PSS integrated loudspeaker connection failure MIC virtual LED that will light up in case of microphone capsule issue MIC Out virtual LED that check the state of the microphone output LCD virtual LED that indicates any LCD screen fault Keyboard virtual LED that light up in case of touchpad issue MIC Cable virtual LED that will light up in case of microphone cable issue Missing virtual LED that light up if the PSS is not plug into DIVA 8 22 2 Keys Page The Key page is where you will define touches for the PSS and their associated action Depending on the PSS model you can specify up to 96 keys so 96 actions lef Keu kep 4 It s important to notice that you can only visualize 12 key at the same time To see up to 96 keys you have to jump to pages with the drop down menu at the upper left corner You also can cut copy paste and delete keys with the upper corresponding button Ateis International 97 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS In or
39. 024 Ecublens Switzerland Phone 41 21 881 25 10 Start Nam Normally Close Open Latch Made start Start Start start Start Start Start start Monitor Mode 108 ATEIS e Normally Close Open Here you can specify the behaviour of the inputs Normally closed means that the contact is closed in neutral position and reciprocally normally open means that the contact IS open in neutral position e Latch Mode By ticking this option you will set the contact to be in latch mode It means that you will need on trigger to open close the contact and one more trigger to get it back to the neutral position v e Monitor By ticking this option in contact or UGA monitoring mode you will define an input as a monitored logical input e Event Setting By clicking start you will be able to associate an event to this input see this to learn more e Monitor Mode With the drop down menu you can choose between contact monitoring mode or UGA mode Contact monitor mode implies the use of an resistor network on a contact see How To Create a Monitorable Button The UGA mode is based on polarizing the input with an external 24VDC source provided by external devices Note The UGA mode is an alternative way of using contact It does not offer real monitoring behaviour and does not increase security 8 24 3 External Fault Inputs As explained before the External fault Inputs have been implemented in order to offer the
40. 1 881 25 10 ATEIS gt i Priority here you can choose a priority level for this event Attrib here you can choose between security event or not See Common Option to learn more about the security option e Next Event you can specify an event that will be started as soon as this event has finished e Stop Event here you can select from the existing event list the event to stop 8 18 3 5 Stop Zone The Stop Zones event can interupt every paging music events in pre defined zone s Stop Zones Event Type stop Zone Priority 20 Gem equals highest Mame Event Z Attrib Security Next Event None Master 1 All Master alfa f2 ataysl eyr s Type displays the type of event that is created in this case Load Preset Name here you can specify a name for the event created Priority here you can choose a priority level for this event Attrib here you can choose between security event or not See Common Option to learn more about the security option e Next Event you can specify an event that will be started as soon as this event has finished e Zone Selection here you can choose in which zones lower priority events will be interrupted 8 18 3 6 Play Message Play message event can start playing messages in pre defined zones after trigger For more information about use of output relay please read this Ateis International 68 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 Play Message Event
41. 2008 124945 6 1234656 M 5 910111213 7 8 910111213 141516171919 20 14151617 18 19 20 21 22 29 24 95 26 27 21 22 29 24 25 26 27 28 29 30 31 28 29 30 31 16 38 Specify a name for the task Default name are Scheduler Task X Tick the option enable in order to make the task available In the trigger event you will find a list of all event that are existing You can edit one existing event by selecting it in the list and then click the Edit button e Select one in the list or create a new event Once the event is selected click on the select button to affiliate the event to the task that is created Select if it is a Single occurrence task or a Cycle task For Cycle task see picture below In case of Single occurrence follow the next few step oO Select a month To change the month use the arrow keys o Select a day Select a hour Use the arrow keys or directly enter it by clicking in the cell o Press Ok Your task is then display in the scheduler window as follow Ateis International 114 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 Scheduler E m E Master Master 1 y 7 Decurence ame Enable Start Time Scheduler Task 1 Single Single 2008 0 0941 6 40 2008 0 09 16 40 Closing Message aa ta e Incase of cycle occurrence please follow the next few steps o Choose the repeat frequency hour day week month or year o Choose the repeat mode permanent number of times or period
42. 41 21 881 25 10 1 Welcome Thank you for choosing ATEIS DIVA8M We at ATEIS hope you will enjoy to use this exciting piece of technology as much as we enjoy developing and building it This Help file version is Ver EN 1 1 This files has been written for the ATEIS DIVA software version VER1 0 1 19 This manual can be updated at any time without prior notice in order to keep this manual up to date In case of errors in this manual or not clear process description feel free to submit us mistakes suggestions or questions by sending an email This document intends to be a complete manual and we hope that this Help file will provide you all information or answers needed However if you have any questions feel free to contact us 1 1 Presentation With more than twenty years of experience ATEIS has quickly established itself as a leading manufacturer of Public Address Voice Alarm systems and counter intercoms The constant growth of market share in Europe provides confirmation of the quality of ATEIS s commercial and technical approach Products The company now offers a full range of sound equipment microphones preamplifiers digital processors digital audio matrixes loud speaker monitoring systems amplifiers etc ATEIS designs and manufactures leading products in the voice alarm systems market which have been certified EN60849 compliant by the TUV Development Thanks to a development team that includes thirty engine
43. 5 10 ATEIS eiss my When music is routed to zone 1 the display shows 540 Ohm As soon as a Voice call is routed on the zone 1 the display will show 545 Ohm If no music or no voice call is routed on zone 1 the display will show 530 Ohm The schematics above explain how the different channel are routed to zone S and how the impedance measurement is made Signal VSix VSgx ISix and ISgx are computed into DSP and then compared to reference values The real measure is made with A and B in parallel In the case the measured value differs from the reference value Line A will be measured independently and compare to the Line A reference and the same process is done for Line B The faults CO Le VT jo VA o ae l Ine CURRENT EJ Tnes_ TRANSFORMER LP O VOLTAGE g TRANSFORMER Se VSix_ ox VS 11 Cancel All and Coexist mode The priority parameter of an event allows it to be started or not if there is already one event active A higher priority event will overwrite zones of a lower priority event in any case The lowest priority event will be temporally disabled while the highest priority event is active If the trigger of the lowest priority event is still active after the highest priority event has stopped the lowest priority event must start again in any case It exists two different modes to manage zone conflict Coexist and Cancel All mode Note Events in the chronograms represent also the corr
44. 8 3 11 Music On By Zone The Music On By Zones event allows to start music source 1 or 2 with any type of trigger in pre defined zone s Music On By Zones Event Type Music Un By ones Priority 20 Zero equals highest Mame Event 11 Attrib Security Next Event None Active at Start Active at Stop Logic Output Logic Output Channel Channel Lenath Length Music Source Music 1 Master 1 All Master sfr 2 3 as 6 78 Ateis International 75 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS Type display the type of event you are creating or modifying Name here you can specify a name for the event created Default is Event X Priority here you can adjust the priority of the event 20 is the lowest 0 is the highest Attrib here you can specify if this event is a security one or not See Common Option to learn more about the security option e Next Event here you can select the event to start after the current on is finished e Active at Start Ticking this option allows user to close an output contact Logic Output channel in two different manner Static will close it until the event stop and Pulse will generate a closing pulse whose length can be defined from 50 to 60000 ms e Active at Stop This option is used to create a closing contact pulse when the event is finished The length of the pulse can be defined from 50 to 60000 ms To learn more about output relay please read the Ho
45. ATEIS ATEIS DIVASM User Manual Version 1 1 Ateis International Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 1 CON a es ann dans es eee 5 1 1 PRESENTATION ER dusnsernetne re catondtiteaestonaedioacbuacmavtwznedlond iucsacedumacdivedbusauasawmactinatdameuasieensdeesdusausstervantineeane 5 1 2 CON CR ee 6 1 3 DNS ALES a ae ana di a aie ol ot 6 1 4 SYSTEM OVERVIEW EE ER EEN NENETS 7 1 4 1 COCO nee em ene EAAS 7 1 4 2 A EE 7 E WEE e E LAA System EE 7 SE SCI OO ces ane esac aos Gass seca canned S 7 1 5 SAFETY DECLARATION ss ssessssessessesersesseseeserseoseseeseosesscoseseoseoseoseeeoseoscoreseoseoseseeeeoseoseoreseoseosesreseoseesee 7 2 HARDWARE DESCRIPTION RE 10 2 1 PRASAT e NEE 11 2 2 DIVASM REAR VIEW a a a a D RNE EENE 12 2 3 DIVASS FRONT VIEW a a a a D dl 13 2 4 DIVASS REAR VIEW a lt 14 3 SOFTA RE E 15 3 1 INSTA TIN PR BGS a N 15 3 2 GUDRS T EE 18 3 3 EE 18 4 CERN EE DEN ICS EE 19 4 1 EVERE 19 4 2 Ge EEN 19 4 3 Se EEN 20 4 4 JB JUNCTION BOX EE 20 5 DIVA PE OPEN a den a etant 22 5 1 FRONT PANE EEN 22 5 2 OT FR tec eet eater A E S 22 5 3 E D KEE 22 6 FRONT PANEL OPERATIONS end ann nn ren een sens nchentee sen nca ncsentense cateeuestecse cRtesnu sentence 23 6 1 N E ee ee de ee 23 6 1 1 Reset L01110 cocscasaneasacnsesonnneceonesesesacenesonmmenscedeenebnanecseseteonuceocessesedensesenennte d cenecouenessese 23 EE 23 6 1 3 Mac REENEN Aessen 24 6 1 4 IP Address
46. Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 Master 1 Note Drag Audio sources here Speaker Parameters Setting Machine PSS Music 1 Enable Front Panel mg 7 QE Voice Amp Music 2Enabie pele Mic Line Enable Message Enable Music Amp e Music 1 Enable by ticking this option the music source 1 will be routed either on the DIVA speaker or PSS speaker e Music 2 Enable by ticking this option the music source 2 will be routed either on the DIVA speaker or PSS speaker e Mic Line Enable by ticking this option the Mic Line source will be routed either on the DIVA speaker or PSS speaker e Message Enable by ticking this option the messages will be played either on the DIVA speaker or PSS speaker 8 18 Use Event As briefly explained before the DIVA action is based on event philosophy Each action is described in event Event can be started by different type of trigger The event created by any manner are all listed in the event page window To access this window go to the menu View gt Event In the Event window you can managed all the event created and see the priority hierarchy next event called sequences and calling event Ateis International 59 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 F Master Master RECHERCHER Event 1 Play M essage Event 2 a LI Deen Mic Paging Select Al Event Type Delete Add
47. Coexist Master 1 Masher Play Mode Continuous Repeat Times Us Ge In the Play Message Event window you will find controls and indicators please refer to the following list Type display the type of event you are creating or modifying Name here you can specify a name for the event created Default is Event X Priority here you can adjust the priority of the event 20 is the lowest O is the highest Attrib here you can specify if this event is a security one or not See How to Use Event to learn more about the security option e Next Event here you can select the event to start after the current on is finished The output relay part is discussed in the How To Use Output Relay please read it Ateis International g2 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS e Message by using the drop down menu you can select in the list of stored message a message to assign to the event Play Mode by ticking continuous the message will be played until a trigger happen Conflict you can choose between Cancel All or Coexist Repeat Time if continuous not ticked you can choose a number of time this event will be repeated In the last section you can specify in which zone this event should take act Please refer to the How To Use Event to learn more e OK will accept the current setting and close the window e Cancel will annulled the current settings and close the window 8 20 Use
48. E 8 23 Use Mic Line Input The Mic Line input can be used as a direct input for one external hand microphone and as an additional music input The input gain can be adjusted by the means of the screw on the back panel of DIVA Ateis International 99 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS i In order to use the Mic Line input first drag and drop Microphone or Line In from the Design Component Section to the Master window Double click the Microphone or Line In icon to enter the Mic Line window see below Mic Line Sele Paging Event Setting Activation Mode e Modulation Detection Threshold D dB Attack Time 1000 Si ms ER 1000 ms Logic Input Input Select The Mic Line has two activation mode e Modulation Detection e Logic Input By clicking the Edit Button you will enter the Mic Line Paging Event window Her you will be able to set up parameters of this event see below Ateis International 100 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 Mic Line Paging Event Type Mic Line Paging Mame Event H Active at Start Logic Output Channel Length Enable ACK Relay Master Slave Logic Output Channel Friority ZU ero equals highest Attrib Security Active at Stop Logic Output Channel Length Enable Busy Relay Master Slave Logic Output Channel Conflict e Cancel Al Coexist Pr
49. E T eenia eenenen E E E E EE EE A EOE 43 8 3 STARTA NEW PROIECT E 44 8 4 CHANGE COLOR SCHEME EE 46 8 5 CONFIGURE NETWORK OPTIONS cccccssccsssccssccssccescccssccusccesccessceusceusccecceusceescsessseesceesccesseeusseusceuees 46 8 6 USE THE USER MANAGEMENT 47 8 6 1 Adad User ere 48 8 6 2 Delete User ACCOUN EE 49 8 6 3 Explanation on User Level sis 49 8 7 END PA NORD E 50 8 8 DR DR setae T EA TEE E 51 8 9 OI es rast cap msn E TE AEE Coscia 51 8 10 KEE ee 51 8 11 A ee ee ome 52 8 12 ADD DESIGN COMPONENT Se de ee ee ne EE 53 8 13 SER Re EE 54 8 14 SE DDR sees weve ates E EE E E 55 8 15 PERFORM A DIVA MASTER NETWORK s0ccescccossccssceccsccssccecceccsccsscceccecesecvsccacccssecsaccesesecseccecenscs 55 8 16 ADD MESSAGES INTO DIV EE 56 8 17 TO SET SPEAKER PARAMETERS SETTINGS exsssscisncosdcesicccddasncnscenstiaceustnnaesavebvacddeverncteedieusbeubedissunnsvaveees 58 8 18 SEVEN Ev i en no eee eee 59 6 18 1 E rags E E E sta sears O E A danse O 61 6 18 2 PVE SOG CC AOE A cea ert SEA nests satiated est cee pias eters see gare pie A AE 62 6 18 3 Ee 65 8 19 SETUP FRONT PANEL MESSAGES EE 81 8 20 USE FIREMAN MICROPHONE ernennen a rR a da Cy eR en eee eee 83 8 21 USE MUSIC SOURCE E 85 8 21 1 From TIC D LOL PAN EE 87 8 21 2 Witt Modulation lettre Ee EE i ceie SS 8 21 3 EE en nan desc ete ent Leo anew dde diese etant Mana isda eae hice ten 59 5 21 4 TE e EE 89 6 21 5 PV OTE LOS OU cata a ao a donc ae on 91 6 21 6 SOMMAIRE E 94 8 22 USE
50. EQ Mixer Voice Channel MIC Line Bypass Bypass E Tone Priority Generator Fireman MIC Bypass Bypass Management e PEU Miner P55 Bupass Bypass Music Channel Frequency Hz o Type here you can choose the filter type high pass or low pass o Slope here you can specify the slope of the filter 12dB 24dB or 36dB Frequency here you can specify the filter cutoff frequency by adjusting the slide bar using arrow keys or writing it directly in the cell o Bypass by clicking on the Bypass button you instantaneously bypass the filter o Graphic by clicking on the Graphic button you will enter the filter graphic edition window see below By moving the blue point you can adjust the cutoff frequency Ateis International 118 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 Hi Low Pass 8 27 2 On Outputs e To add high or low pass filter on audio amplifier outputs double click on the icon PEQ Voice Channel or PEQ Music Channel in the DSP Configuration Window The following window pops up Note more explanation about amplifier output PEQ can be found here n DAME Overflow Signal EEN Bandwidth dr Da i Ate s International 119 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS
51. ER TT E EEEE TESTENE 24 6 1 5 EAR 25 OO OS 6 101 023 EE 25 Ca EE 25 E CR TCE Te eRe EnERTE Ere SES er EETeT eye SEE T ner e Ty re rere creer eter creer 25 EES 26 6 1 10 PN AA SEINE NI 26 6 1 11 EE E D A 2 RER D AE 26 6 1 12 M S EE 26 6 1 13 Get Reference eeeeeeeeeee an eeeeeeeeeeeaeeeeeeeeeeeeeaaeseeeeeeeeeaaaeeeeeeeeeesaaaaeseeeeseesaaaaeeeeeeeeeaas 26 6 2 EE 27 6 2 1 POES OR Se Tee meee eee eee eee en een eee aero 27 6 2 2 DO LORS E 27 6 2 3 OAI tac EE 27 6 3 MESSAGE AND MICROPHONECALL 27 Or 7 CACY E PR Te eee aan de D ein 27 6 32 E E 28 7 DIVA SOFTWARE PRESENTA TION seseesesecsesesccsescosesecccseseoceseseosesecccseseosesesccsesesccseseoseseseoseseseeseseo 29 7 1 RN E E E 30 Ateis International 2 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 7 2 KENNO AR a a a a ee ee 7 24 TTY EE EEN E EE 123 a Denon de A D ae oi sn 7 24 OR a Gakic 5 40 4 ein ee ae et D a te one E OOM RSR gine Sato vec S AEEA hc ag sede nasa aos sn ee Saco nein dee eon sae 7 2 6 OO ed eo EE ER ede T 7 2 0 NO E E E EA MC E OEE OTE E AREE te de E O AEE AA caves le A T 7 3 TOLAR a E EE ee EE 7 4 TAE DAR EE 7 5 DESIGN COMPONENT SECTION ee 7 6 DEON VEN EE 7 1 PROPERTY CONTROL SECTION ee 7 8 SR E 8 HON TO EEE 41 8 1 Be OPN ses basta ese sees ane apices aceitnne sesame sass enue uecaneeacaeounne N E A A E 41 OM HOD E EE E E E E E E E E 42 8 1 2 S viaccess cee veer ess ee ac cies recess A ATE 42 8 1 3 A 42 E E E 42 8 2 E
52. ESSE Ate s International 122 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 e Double Click on the PEQ icon to enter the PEQ window see below PEQ MIC Line e Adjust the PEQ parameters to suit your needs o Bandwidth Oct here you can adjust the Q factor of the PEQ either by using the slide bar arrow key or by entering directly the value in the dedicated cell o Frequency Hz here sou can adjust the central frequency of the PEQ either by using the Slide bar arrow key or by entering directly the value in the dedicated cell Oo Gain dB here you can adjust the PEQ gain either by using the slide bar arrow key or by entering directly the value in the dedicated cell o PEQ Overflow Signal indicates if there is an overflow after the addition of the PEQ to the base signal o Bypass All by clicking on the Bypass All button you will instantaneously bypass all three PEQ filter o The first PEQ filter can be changed to a High pass filter with the corresponding drop down menu o The last PEQ filter can be changed to a Low Pass filter with the corresponding drop down menu o By clicking on the Graphic button you will enter the PEQ graphic edition window You will be able to adjust gain and central frequency of each PEQ by moving the yellow cursor Bandwidth is controlled by the orange cursor Ateis International 123 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS
53. Get Reference menu You can get reference individually for each speaker zones and amplifiers Ateis International 26 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 Use the arrow keys to access the Get Reference menu Press OK Choose between zone 1 8 or Music Amplifier Voice Amplifier Press OK The new monitoring reference is now made and stored 6 2 Music On DIVA front panel you have the possibility to assigned music sources to a zone or multiple set up attenuation for each speaker zone and to toggle between music sources This will be possible in the case you set music in Route Key mode see How To Use Music Source 6 2 1 Zone Selection The zone selections have been designed to be simple In order to select a zone please follow the next steps e Press the zone button s you want to activate The corresponding green selection LED s should light s up Choose the music source you want to route Press the Route button 6 2 2 Source Selection The DIVA front panel offers the possibility to toggle between two music sources or none e Press the SELECT button to go from Source 1 to Source 2 e Press SELECT button to go from Source 2 to no selection e Press SELECT button to re select Source 1 6 2 3 Attenuator In each zone the music level can be attenuated depending your needs e Adjust the corresponding zone s ATTENUATOR KNOBS to the desired level Note if two music sources are used keep in min
54. HONE 6 O R R ZONES ZONES ZONES ZONE ZONES TP On EXTERNAL FIREMAN MICROPHONE MUSIC INPUT AA MASTER 2 ZONE 4 ZONES ZONEG ZONE ZONES Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ETHERNET PORT LINK OUT LL LA es PSS PSM RS232 z GAIN MIC LINE ETHERNET PORT LINK OUT ATEIS POWER SUPPLY 1 54 KA SEN REMOTE EXT POWER SUPPLY 1 54 x gg EEER aG Lio LA GAIN MIC LINE PSS PSM RS232 ETHERNET PORT LINK OUT g T a La ogo Ld Ga REMOTE EXT GAIN MIC LINE PSS PSM RS232 ETHERNET PORT REMOTE EXT dr POWER SUPPLY E POWER SUPPLY 1 54 To Docs GAIN MIC LINE RS232 REMOTE EXT Im rm pm rs len Mt ET NETWORK Se 138 ATEIS 8 33 13 RS232 COMING SOON 8 33 14 DIVA8S To connect one slave DIVA to a master simply connect the Link Out connector of the Master to the Link In of the slave with a RJ 45 CAT5 cable and so on for the next slave unit To pass the audio to the slave unit simply connect the Master 100V Link connector to the slave 100V In connectors If more than 500W of power is needed you can add two amplifier channel per slave unit To synchronize the audio simply link the OdB output of the master to the additional amplifiers OdB input and additional amplifier 100V output to the corresponding 100V slave input The first schematic shows how to perform a DIVA
55. IN for negativ OdB output GND for OdB ground output The 100V input are named as follow e AQOUT for positiv 100V input e AOQOUT for negativ 100V input According to the schematic below the DIVA OdB output are linked to the amplifier OdB input and the DIVA 100V input are linked to the amplifier 100V output Depending on the configuration needed you can use the amplifier fault output to force DIVA to enter security mode in case of amplifier failure To achieve this aim simply connect the DIVA EXFLT connector to the amplifer FAULT connector To learn more about amplifier connection please refer to the amplifier manual Ateis International Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 134 ATEIS 24 8 FF nog D Co gt ee EXTERNAL FIREMAN MICROPHONE ETHERNET PORT LINK OUT POWER SUPPLY MUSIC Or A en O Flu OO LJ oo L 1 2 GAIN MIC LINE PSS PSM RS232 REMOTE EXT 8 33 7 Speaker Lines In order to have a high accuracy on impedance measurement you should add an end of line capacitor on each speaker line If help is needed to know the value of those capacitors please take contact with Ateis When connecting speakers take care of the polarity D g S BEER EXTERNAL FIREMAN MICROPHONE ETHERNET PORT LINK OUT MUSIC INPUT POWER SUPPLY 1 5A OO ii amp LI cH L ZONE nt A tt f m ZONE4 ZONES ZONES E8 1 2 GAIN MIC LINE PSS PSM RS232 REMOTE EXT
56. Line Enable Message Enable E Music Amp The default tab in the monitoring window is the Zone Monitoring see below To enter the voice or music amplifier monitoring page simply click on the corresponding tab in the tab bar Monitoring E m E Erm d Zone Monitoring Voice Amp Music Amp Referenced Dhm ReferenceB Ohm Reference B Ohm Connected Source Tolerance Measure Ohm Diff 4 15 H dF F i OT on t dF dF F 7 l i OH Z ak dF FIFI F F ab l 3 5 8 Monitoring period eo Weier ll deg RE d et Monitoring Ate s International 110 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS OG To learn more about how the monitoring is perform please read Explanation About Monitoring Process 8 25 1 Zone Monitoring f Monitoring Si E Zone Monitoring Voice Amp Music Amp Referenced Dhm ReferenceB Ohm Reference B Ohm Connected Source Tolerance Measure Ohm Diff 4 15 i 15 15 15 15 15 15 15 4h Ak Ak Ak Ak Ak ak ak F FIF F F F F F 2 E 4 z B d D Monitoring period A Monitoring period if LS EU ER TE Zone Monitoring display Zone displays the zone number ReferenceA Ohm displays the value taken as reference for line A of one zone ReferenceB Ohm displays the value taken as reference for line B of one zone RefereneA B Ohm displays the value taken a
57. MICROPHONE ETHERNET PORT LINK OUT MUSIC INPUT ER L 14 rO Or a LJ owe LJ CC ZONE 1 2 i PS5 PSM R3232 REMOTE EXT 8 33 11 100V Outputs The 100V outputs have been made to link the 100V line from a master DIVA to a slave DIVA To learn more on how to do the connection between master and slave please read this EXTERNAL FIREMAN MICROPHONE ETHERNET PORT LME POWER SUPPLY MUSIC INFUT 154 ON LO Oe o Ei OVW EO ZOMEZ ZONE Fo dr L H GAIN MICHUNE PSS PSM RS2a2 REMOTE EXT POWER SUPPLY 1 54 d d E a KEIER A A O A A Gd A d E a A A d A O EE K cl ts cl Leer Ge Lee Ge uv Doug Leer Ge WI LINK IN LINK OUT 8 33 12 Computer The computer can be directly connected to a master DIVA by using a CAT5 cable or can be connected to a ethernet network using the same type of cable The next two schematics are example on how to connect masters DIVA to a computer Ateis International 137 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 EECH ZONE nt tt Lag ZONE2 ZONE ZONE1 ZONE Ate s International E2 nt gt ZONE ZONE2 ZONES a d ZONES ZONES ZONES MASTER 1 DH S EXTERNAL FIREMAN MICROPHONE di Or HEHH ZONES ZONEG ZONET ZONES MICROPHONE MUSIC INPUT d Lag wg ug ZONES ZONES ZONE6 ZONE ZONES MASTER 2 MASTER 1 Ca D DS KKK TONIN vu EVACUATION INPUTS EXTERNAL FIREMAN MICROP
58. PS SIMIC R e Te 95 6 22 1 SE 95 022 2 PACA a E EATA E EEEEaEEEZZZZZE 97 8 23 USE MICLINE INPUT WEE 99 8 23 1 WihModuanon DCIECHION EE 102 Ateis International 3 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 6 23 2 From Logic Jung 10 8 23 3 From O WV TC ee ee Eege 8 24 EE 8 24 1 Normal LOGIC INPUTS ciinii rr ENAA EEEE E EA 8 24 2 Ee EE 8 24 3 EE T auli INPUTS RE 8 25 EE 6 25 1 PORC VOTO EEOSE AIEEE VOEN en toon Aaa OEE E D cn nn 8 29 2 EE 8 26 EE TA CBD UIE eege 8 27 NOSE aie ME TERS ee UET EN D EE EAGEN 8 27 1 OR E E E E ee os 0 2 2 COMMISE de E van dee baie EE eh ieeee uae 8 28 e Ee 6 26 1 OIG EE 6 25 2 OOS saci de stab un td li 8 29 NSEC ORE SORT eege 8 30 UC AN A E E E E A E E TE E 8 31 05528 00h 20M 41 RS te ne ener ere er ree E te ey eer eer ere ere tT ern errr 8 32 CREATE A Ten e E CHE E KEE 8 33 ENEE 6 33 1 EE 8 33 2 EE 6 33 3 EE 8 33 4 EE 8 33 5 T EE 8 33 6 EE ee 6 33 7 EE 6 33 8 Normal Logic INDUS aeii nn i E AEE 8 33 9 EE 6 33 10 Een 6 33 11 DOO VO D E 6 33 12 Ee 8 33 13 D E E E A E 8 33 14 DI E 8 33 15 Reno FON SR 8 33 16 E RS dan A AE E T TETEE EE terrtere 8 34 USE Kee 9 COMMUNICATION PROTOCOLS a ns cecceentenetiendeectuenenetteneeeccteececes 140 10 EXPLANATION ABOUT MONITORING PROCESS eeeeccscsssscccccccsseccecccccsseccccccoseecceccccsseccccccossecceee 141 11 CANCEL ALL AND COEXIST MODE eege 142 Ateis International 4 Ch du D vent 1024 Ecublens Switzerland Phone
59. Revere Close 8 12Add design Component After starting a new project the System window is opened On the left you will find the Design Component Section The DIVA software have been made to simply add remove component All the component are drag amp drop items Each component can only be dropped in its own place 53 Ateis International Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS DE Audio Source a Fireman Microphone d D s Music be Microphone ET Line In D Audio Component af Filter gt Hi Lo Pass Compressor Limiter 7 Compressor Limiter Le Compressor Limiter 8 13 Search Device To perform a device search go to the menu Tools gt Device Search The Device search window will open see below Device Search Enable DHCP Name Lave Comeet menuet Cornet seach 0 Ges Ateis International 54 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 Buttons explanation Search starts the search process A progression bar indicates when the search is finished e Auto Connect allows to connect to a master DIVA that have been found Select a master in the list by just clicking on the corresponding line Note attention do not select Enable DHCP when clicking on the line it could cause connection problem e Manual Connect allows to quickly connect to a known master DIVA IP without doing the search process e Close closes the Device Se
60. SK Music Source Selection Buttons and Indicators For each zone you can set an attenuation The attenuation are from OdB to 20dB Note if two music sources are used keep in mind that attenuator will only have effect on only one of them music 1 This is due to the fact that the amplifier used for the music source 2 is the one dedicated for voice call 8 21 2 With Modulation Detection The modulation detection mode allows to automatically route music sources in case of signal presence You can set up both source one and two in modulation detection as well as only one source The normal use of this options is to set up one source in permanent mode and the other one in modulation detection example tuner in permanent and CD player in mod det Keep in mind that in that mode the music front panel buttons are disable e Modulation Detection e Modulation Detection Threshold dB T 0 z Attack Time ma 1000 1000 Release Time ms 1000 1000 Ate s International QQ Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS In order to use the modulation detection tick the Modulation Detection option for the source you want to use that way Once the option selected you will have access to detection settings e Threshold dB The threshold setting will set the trigger point for activation of the music source If the threshold is set to
61. a None S Overflow Messages Pre None None New Ea M Le Prost Message 3 None e E Speaker Overflow Message 4 PRE AMP Lo SPE Cable a MIC MIC Out ES LCD Keyboard MIC Cable ca Missing Mode No Fault If Missing if ticked DIVA won t display a fault if the PSS is not physically connected e Press To Talk this option change the behaviour of the Mic key on the PSS screen from Lock to Talk to Push to Talk For calling in Push to Talk mode you have to keep the PSS Mic key press as long as you want to talk e Security source if ticked you will be able to use the PSS microphone when DIVA has entered into the security mode When ticked it adds the option Evacuation Source If evacuation source is selected the paging from the PSS will act like an evacuation event So the front panel EVAC LED will light up Options e Buzzer On this options allows user to enable the PSS buzzer It will beep for any DIVA fault status and for PSS internal fault e External Microphone in case of using an other microphone that the gooseneck you will have to tick this option Chime selection e Pre allows to add a chime message at the beginning of a microphone call Simply choose the pre chime message from the drop down menu e Post allows to add a chime message at the end of a microphone call Simply choose the post chime message from the drop down menu Selected Messages Ateis International 06 Ch du D vent 1
62. amed and offer settings that could differ from those described in this chapter Ateis International 60 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS Load Preset Logic Output Command String Stop Event Stop Zone Play Message Fireman Mic Paging MIC LINE Paging Music ON Music OFF Music ON By Zones Music OFF By Zones Toggle Music ON OFF Toggle Music ON OFF By Zones Security Mode Stop All Event 8 18 1 Common Options Security Option The Security option is common to all event type If the security option is selected this event will be able to be started when DIVA has entered the security mode This mode have been created to enter a power safe mode in case of power supply failure in order to save energy when supply by emergency battery This mode is automatically launched when using External Fault Inputs Zone Selection In many event you will be able to choose some pre defined zones Here is the zone selector display and explanation Master 1 All Master HEHE 145 61778 From Left to right and up to down Master 1 correspond to your project name master unit plus slave ones o All selects all zones of master and slave s units Master means master unit o All selects all zone of the master unit o 1 8 allows to select independently zone 1 to 8 from a master and or slave unit Cancel All and Coexist options The Cancel All and Coexist options have been created to
63. amplifier channel Deeg MEASUREMENT UNIT NOTE If the amplifier gain is changed after the reference has been taken the pilot tone level could increase dramatically Example the reference is taken with a gain of 1 the pilot tone will be set to 2Vrms Then if the amplifier gain is increased to 100 the pilot tone level will be raised to 200Vrms To avoid problems the gain of both Music and Voice amplifier should be set to same value and in preference to the maximum gain value There is three different channel for monitoring Voice amplifier channel Music amplifier channel and VO3 channel VO3 is channel that only generate the pilot tone in case no amplifier channel is in used Zone Monitoring Zone Monitoring is based on three different reference values Line A Line B and Line A B Reference for Line A and Line B are Line A and Line B direct impedance measure Reference Line A B correspond to the Line A and B in parallel Line A Za Line B Zb Line A B 1 1 Za 1 Zb To ensure a high precision measure for each reference A B and B A three values are taken Example Line A VO3 channel Line A Voice amp channel and Line A Music amp channel In the references display the value will change according to channel routed on each zone Example Zone 1 Line A ref VO3 530 Ohm Voice 545 Ohm Music 540 Ohm Ateis International 141 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 2
64. and password Please check the user level explanation as well as How To Enter Password 6 1 Menu The menu display offers the possibility to access different controls and system information Here are the list of menu topic you will be able to access Reset Monitor Logout Mac Number IP Address Set Time Speaker Level Log files Mic Lines Stop All Events Ethernet Setting Music 1 Level Music 2 Level Get Reference The front panel buttons are described in the hardware description gt Front View 6 1 1 Reset Monitor The reset monitor menu allows user to reset the speaker line monitoring after fixing an eventual line problems Press the arrow keys to acess the Reset Monitor menu Click Ok it will display Are you sure to rest monitoring Click OK Press ESC to go out of the menu 6 1 2 Logout In case of multiuser levelling you can logout from the current user session in order to login in an other one e Use arrow keys to access the Logout menu e Click OK it will display Are you sure to Logout e Click OK e You will be prompt to login Ateis International 23 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 Enter your user name Enter your password You will be log in a your user account Press ESC to go out of the menu 6 1 3 Mac Number In the world of computer networking there is one common way to set an quasi unique identifier to a network device This is the MAC address Media
65. arch window 8 14 Set IP Address From the front panel of DIVA you can change the address from the LCD menu display In order to do this please read this IP submask and gateway address can also been changed from the software by going in the device search menu Tools gt Device Search Device Search Enable DHCP IP Address Subnet Mask Gateway Address Modify IP Master 1 192 166 1 201 255 255 255 0 192 168 1 1 Modify 4uto Connect Manual Connect Once a DIVA unit has been found click in the IP Address Subnet Mask or Gateway Address field to be able to change the current value To save the new settings click on Modify Note you have to keep in mind that setting TCP IP parameters not related to the one set for your network card could lead to communication problems 8 15 Perform a DIVA Master Network As briefly explained before you can put several DIVA master on a same network The DIVA master network is based on Ethernet protocol Keep in mind that DIVA slave unit are not on Ethernet network In order to complete a DIVA network you will need the following devices e Ethernet Switch Hub e Multiple DIVA8M units e A computer Before connecting those devices on the network you need to check the IP address of each DIVA master units and set each DIVA IP address corresponding to your project s network By default a new DIVA8M unit has the following IP 192 168 100 100 See How to Set IP Adress Ateis International 55 Ch
66. ass PEL Mixer Voice Channel MIC Line Bypass Bypass i E Tone Priority Generator Fireman MIC Bypass Bypass Management 7 _ FEG Mixer e RSS Bypass Bypass Music Channel There is two ways to access the PEQs on amplifier outputs by double clicking the amplifier icon Voice Amp and Music Amp on the Master window see below or directly by the DSP Configuration window Ateis International 121 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 Master 1 Note Drag Audio sources here J Speaker Parameters Setting Machine PSS Music 1 Enable LI H Voice Amp aron a Music 2 Enable ER D e Mc me Enable wi Message Enable ER E busie Amp 8 28 1 On Inputs e To add PEQ on an input drag and drop the PEQ from the filter menu in the Design Component Section Note if there is already hi lo pass filtering on the same input you won t be able to add PEQ on that input On one input you only have one filter location and can use either PEQ or Hi Lo Pass filtering Master 1 DSP Configuration Note Drag Audio components here Compressor Limiter Filters Bypass FELG Bypass Eupass PEG Mixer Voice Channel MIC Line Bypass Bypass i Tone Priority Generator Fireman MIC Bypass Bypass Management PEG Mixer PSS Bupass Bypass Music Channel PPM M
67. below Ateis International 92 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 Events Selection Select Event List Name Priority Type Security Name Priority Type Security Event Select Al Select All Shift Up db Insert New Edit Delete e Select Hone Select None Shift Down On the left side you will find the list of existing event To create a new event simply click on New under Event As soon as you click on the New button the software will ask to choose a event s type see below Master Select Master 1 Event Type Music On In order to select an event s type use the drop down menu Then click OK After you have press OK you will return to the Events Selection window To edit your new event settings select it by clicking on the right line and then click Edit Note don t click in the square selector The corresponding event s type window will pop up After your event settings are complete click OK The last step is to affiliate the event created with the logical input In order to do so tick the square selector and click on insert Note you can associate more than one event to an external trigger as well as creating event sequences To learn more about it please read this When logic input have set for music sources you can find a list of logic input associated to music source on the music source window in Logic Input drop down menu Ateis International 03 Ch du
68. can set a time for which the manually zone selection is kept in memory Since this time has passed the next fireman microphone called will be routed in the pre define zone e Push to talk with this option ticked you will need to keep the microphone button pressed in order to be able to talk e Lock To Talk with this option ticked one pressure on the microphone button will start the call and one more pressure will stop the call For safe operations you can set a time after which the call is automatically stopped Fireman Microphone Paging Event Setting t evel dB Volume dB Paging Mode EN a Zone Release Time 5 e Push To Talk Lock To Talk Pon soo a pieje AE Eo 7 Overflow The Fireman Microphone Paging Event window see below is divided in several section where you will be able to set e Priority you can specify a priority level between 20 and zero The highest priority level is 0 when 20 is the lowest e Security by ticking security you will allow user to make a call when DIVA is in security mode e The next portion of the window is dedicated to the output relay management In order to find out to use please see How to Use Output Relay e Conflict here you can choose how to manage priority conflict Cancel All consists of cancelling all the messages or events with a lower priority that are currently playing in the selected zone Coexist permit to momentarily disable the cu
69. ck time can be set from 0 ms to 5000 ms e Release Time ms As opposed to the Attack time the Release time is the amount of time for which the signal have to stay under the threshold point before deactivation of the Mic Line sources A correct Release Time can avoid inopportune deactivation of the music source pause in speech The release time can be set from O0 ms to 5000 ms Setting those parameter correctly needs some experience so be careful and please test it to learn more about the behaviour of this option Once your modulation detection parameters are adjusted you have to edit the advance setting for the Mic Line please refer to the Use Mic Line Input general chapter Ateis International 102 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS see N se 8 23 2 From Logic Input Mic Line routing can be operate by external trigger that means with the help of the logic evacuation or even external fault inputs In order to access the logic inputs menu go on menu View gt Logic Inputs The Logic Inputs page will pops up see below Logic Inputs Normal Logic Inputs _ LE vacuation Inputs ME ternal Fault Inputs k Channel 1 Normally Open Start Channel 2 Normally Open Stark Channel 3 Normally Open Start Channel 4 Normally Oper Start Channel 5 Normally Open Start Channel amp Normally Oper Start Channel 7 Normally Oper Start Channel Normally Oper Start DIVA Machine Master 1
70. ction to the master window aa Master 1 Sele E Ca DIVA System za Master GH Audio Source PSS Note Drag Audio sources Music hela Microphone gei Line In H Audio Component a Front Panel Hagen Setup q Voice Amp Music Ame To access the PSS window simply double click on the PSS icon on the master page In the PSS window you will find two different tabs one for property settings General and one for Keys configuration Key 8 22 1 General Page Here is a list of what you can parameter in the General tab Properties Section Name here you can set a name for your PSS Priority here you can set the PSS priority Take care when choosing a priority as the PSS could be a security microphone as well as a evacuation source e Access Code you can specify an access code only number in order to be able to use the PSS screen e Language allows user to set the PSS screen language between French English Russian Romanian Polish and German Ateis International 95 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS ER General A Key Propertie Hame Priority 20 ero equals highest Access Code Digits only Language French Mode Uptior No Fault IF Missing Buzzer ON Press To Talk External Microphone Security Source Selected Message Messaged Mic Level Chime Selecti
71. d that attenuator will only have effect on only one of them music 1 This is due to the fact that the amplifier used for the music source 2 is the one dedicated for voice call 6 3 Message and Microphone Call From the front panel you have the choice two start three different messages or do a zone call with the fireman microphone See those two chapter for more information about how to set up messages and how to configure the Fireman Microphone 6 3 1 Messages Next steps are for zone selection in case of starting a message e Press the zone button s where you want the message to be played The corresponding green selection LED s should light s up e Press the desired message button the message will start performing in the zone If EVAC message the corresponding EVAC LED s should light s up If Test or Alarm message the corresponding PAGE LED s should light up Note If the message set on the front panel have been defined with pre defined zone pressing only the message button will result in starting the message in the pre defined zones Ateis International 27 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 6 3 2 Fireman Microphone Next steps are for zone call with the fireman microphone e Press the zone button s where you want the call to be played The corresponding green selection LED s should light s up e Press the fireman microphone contact to start speaking in the selected zone s the corres
72. de triggered by logic in Event 3 priority 1 zone 3 and 4 conflict mode whatever Fireman microphone Figure 4 in Cancel All mode Event 1 priority 20 zone 1 and 2 Cancel All mode triggered by logic in Event 2 priority 10 zone 2 3 and 4 Cancel All mode triggered by logic in Event 3 priority 1 zone 3 and 4 conflict mode whatever Fireman microphone Event I P IL TI Event tt T In Re BE BE Event 3 ll Uo zone LL J LiL Zone 2 JL Zone 3 BN J NEEN a BE Zone 4 I J fF FL Figure 3 Chronogram with 3 events in coexist mode _ NS ON IL TI Event D TI JLE wns Up Sege Lot U zone 2 U JI zones zwa Figure 4 Chronogram with 3 events in Cancel All mode Ate s International 144 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10
73. der to create a key follow the next few steps In the three square enter a key label 3x 6 digits With the drop down menu select a key type some keys type will automatically open a popup window for parameters setting see below for the complete list ok key functions e Edit your key settings by clicking on the Edit button Key functions e Zone Selection The zone selection key allows user to arrange to his will the selection of the zone As soon as the zone selection type has been selected the zone selection window will appear Simply tick the zone corresponding to your needs and click OK fone Selection Master 1 All Master CORRE ES e Route The Route key act like the one on the front panel it has to be used to validate the routage of a music source in some zones e Music Source Selection When creating a music source selection key you will have to specify the corresponding music source with the help of the musis source selection window Key Setting E m E e Music Level Music Level The Music Level and need to be associated with a music source The selection of the music source is made with the music source selection window Note Music Level and Music Level are two distinct keys Key Setting Sel Ateis International 98 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 e Speaker Level Speaker Level The Speaker Level keys act on the PSS internal
74. du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 After the devices have been connected and in order to know if your network is well configured go to the Device Search window Tools gt Device Search and start a search If some DIVA master aren t visible please check wiring and or IP address settings Also check your computer network card parameter and be sure they are set in accordance to the DIVA network builded NOTE DIVA master won t be able to communicate with each other through the network This network only intend to offer quick configuration solution over IP 8 16 Add Messages into DIVA In order to store messages into DIVA memory you have to use the message manager window e Go under menu View gt Message The message window will pop up see below e Inthe upper part of the Message window you can select the DIVA master unit you want to work on for messages Message Manager Master Master 1 Local Memory Ready to Store Stored itd Chime 3 notes wid 63 37kB Chime 3 notes Way 63 37KB Alarm DE wav T r 23kE Alarm DE way 177223KB 07 Evacuation EN way Ki kb O Evacuation EN way 239 95KB 5 Test SP way eles E Test SP way Select All Shore Select All MSG Library Delete Select None Delete Memory Used K 0 87ME 100ME The message window is divided in two section one for the message taken from the message library left one and one for the m
75. e Save as Opens the Save As dialog window to choose file path and name Open Opens the Open dialog window to choose an existing file path and name Open autosaved Opens the last automatically saved file Recent files Pathhame gt gt Quick access to recently used files Print Starts printing Exit Terminates the current LAP session after asking to save modified files 7 2 2 Edit Here you will find all the common basic edition tools of windows based software e Undo ctrl z Will undo the last actions e Redo ctrl y Will redo the last action or will retrieve the last state in case undoing too far e Cut ctrl x Cuts out the active selection and copies it to the operating system s clipboard e Copy ctrl c Copies the active selection to the operating system s clipboard e Paste ctrl v Pastes the content of the operating system e clipboard e Delete Del Deletes the active selection 7 2 3 View The commands in this group are used to call closed or invisible control windows and toolbars Ateis International 31 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS Oper atior System Preset List LED Display System Status SPIO LED Language Toolbars e System Calls the System library control window to add and create a network system e Preset List Calls the Component library control window to choose DSP components e LED Display Calls the System Status contr
76. e Chime Pre Chime Enable Pre define one Pre detine one Enable Master 1 All Master alfa f2 3 as 6 78 Type display the type of event you are creating or modifying Name here you can specify a name for the event created Default is Event X Priority here you can adjust the priority of the event 20 is the lowest 0 is the highest Attrib here you can specify if this event is a security one or not See Common Option to learn more about the security option e Next Event here you can select the event to start after the current on is finished e Active at Start Ticking this option allows user to close an output contact Logic Output channel in two different manner Static will close it until the event stop and Pulse will generate a closing pulse whose length can be defined from 50 to 60000 ms e Active at Stop This option is used to create a closing contact pulse when the event is finished The length of the pulse can be defined from 50 to 60000 ms Ateis International 101 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS eis i e Enable ACK Relay here you can set the closing of a Logic Output Channel relay as soon as zones where an event has to be played are freed from higher priority events e Enable Busy Relay here you can specify an Logic Output Channel relay that will be closed as soon as you will trying to speak in zones where a higher priority event currently playing To learn more
77. e able to add design components and set settings for the integrated speakers of DIVA and PSS Ateis International 45 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS 8 4 Change Color Scheme In the Color Scheme Options page you will be able to personalize the colour scheme of DIVA software You can change colour for Background Label DSP element Other Windows and Buttons By using the Use Default button you can retrieve default color scheme Background Others LES EE Windows Color 216 228 248 Start Color 216 228 248 e End Color D 157 185 235 Button Color bite woe Label Preview vw Use Gradient Color Start Color 216 228 248 sen Lahel End Color 157 185 235 Button DSP Element __Euton Start Color 202 202 255 End Color M 36 96 255 ee Button Use Default 8 5 Configure Network Options In order to be able to communicate with DIVA master units you have to set your network parameters In the Network options page you can specify your network card the UDP port value as well as the RS232 port number Ateis International 46 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 Options File Color Scheme Network Ethernet Network Card Broadcom Net treme Sixx Gigabit Controller Miniport d ordonnancement d e UGF Port 19700 R5232 After all the network options have been set
78. e frequency range to your needs To do so you have to access to the DSP Configuration Ateis International Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 116 window e Inthe Master window double click on the DIVA icon The DSP configuration window will pop up Note if no audio sources have been set into the configuration the corresponding Filter and Compressor Limiter location will be grayed F Master 1 DSP Configuration Note Drag Audio components here Compressor Limiter Filters Bypass Bypass Bypass Bypass DEU Mixer Voce Channel MIC Line Bypass Bypass li Tone Priority Generator Fireman MIC Bypass Bypass Management j FEQ Miser PSs Bypass Bypass Music Channel On the left of the DSP Configuration window you can find all audio inputs and on the right amplifier outputs 8 27 1 On Inputs e To add high or low pass filter on audio input drag and drop Hi Lo Pass filter from the design component section on the Filters location see picture below Note you also can add high and low pass filtering by using the PEQ filter on input read this Ateis International 117 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 2 Master 1 DSP Configuration Note Drag Audio components here Compressor Limiter Filters Bypass Hl oa Pass Bypass Bypass e P
79. e specified every user can unlock the software Compile Compiles the current configuration and displays eventual errors Ateis International 36 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 Store Upload configuration parameter into the DIVA s parameter memory Reverse Downloads the DIVA configuration in the computer e Connect Establishes data connection to the machine s in order to monitor or adjust parameters online Disconnect Disconnects DIVA software from the machine s e Audio Enable Enables DIVA s audio processing e Audio Disable Disables DIVA s audio processing e Stop All Events Stops all running events 7 4 Tab Bar Opening design or component control windows creates a new tab within the tab bar The active window is orange highlighted and can be closed by clicking the close box at the right side of the bar Milne PeASdAGiah at ges fulk additianal orange coloredarraw eantrobooxeswilbappear atihesright side of the tab bar Click on the left or right arrow to move the content of the tab bar to the left or the right 7 5 Design Component Section The Design Component Section shows in a tree folder arrangement all element that can be connected or added in a DIVA configuration All the component are drag and drop component errors are avoid thanks to the emplacement identification See How to Add Design Component Ateis International 37 Ch du D vent 1024 Ecublens Switzerland
80. eis International 29 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS A 4 Tab Bar Shows the window title of all open design and component control windows for quick access 5 Design Component Holds all design component libraries Section 6 Design View Area This area is your work space showing all design windows and component control windows 7 Property Control This section slides up for System Status LED Display Section 8 Status Bar Displays useful status communication and compiler information 7 1 Title Bar The title bar displays DIVA Untitled if you start a new system design or the full path name of the saved file At the right hand corner you can find the usual Windows minimize button and the close box which exit the program 7 2 Main Menu Bar File Edit view User Operation Tools Lock window Help The main menu bar contains the following menus File Edit View User Operation Tools Lock Window Help 7 2 1 File In this paragraph you will find everything related to system files as well as printing command All the DIVA files are saved under the diva extension Ateis International 30 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS view User Ctrl M s 5 Open ChrltO Open Aubosayved Recent Files Print Exit Ctrl g New Opens a new system file Save Saves the current system fil
81. el 5 Normally Open Start Channel 6 Normally Open Start Channel 7 Normally Open Start Channel Normally Oper Start DIVA Machine Master 1 e Normal Logic Inputs The eight normal logical inputs are simple logical inputs with no monitoring options e Evacuation Inputs The nine evacuation inputs can be used as simple logical inputs as well as monitored logical inputs Monitoring type are on contact or voltage UGA In contact monitored mode and using a resistor network the measurement unit can detect 4 different states 1 3 V 2 V 2 7 V and 4 4 V The 4 states correspond respectively to Shortcut Closed Contact Opened contact and Absent open line The voltage UGA monitoring mode is based on polarizing the input with an external 24V source e External Fault Inputs External Fault Inputs are used to put DIVA into security mode The way to configure event for all logic inputs type is identical Please read the few next step to know how to associate an event to a logic input Click on the Start button under Event Setting The Events Selection window will be open see below Ateis International 106 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 Events Selection Select Event List Name Priority Type Security Name Priority Type Security Event Select Al Select All Shift Up db Insert New Edit Delete e Select Hone Select None Shift Down On the left side yo
82. en Start Start Start Start Start Start Start Channel Normally Oper Start DIA Machine Master 1 e Name Here you can specify a name by simply clicking in the box Normally Close Open Here you can specify the behaviour of the inputs Normally closed means that the contact is closed in neutral position and reciprocally normally open means that the contact is open in neutral position e Latch Mode By ticking this option you will set the contact to be in latch mode It means that you will need on trigger to open close the contact and one more trigger to get it back to the neutral position e Event Setting By clicking start you will be able to associate an event to this input see this to learn more 8 24 2 Evacuation Inputs Evacuation input have been design to offer monitoring on logical inputs as well as UGA mode even though they can be used as normal logic inputs in order to provide an higher security level for external trigger ogic Inputs Mormal Logic Inputs Evacuation Inputs External Fault Inputs Channel 1 Channel 2 Channel 3 Channel 4 Channel 5 Channel amp Channel 7 Channel 2 EE DIVA Machine e Name Here you can specify a name by simply clicking in the box Ateis International Normally Open N ormally Open N ormally O pen Normally Upen Normally Open N ormally Open M och 0 pen Normally T pen Normally Open Master 1 Ch du D vent 1
83. en two music sources or none zone selection and Fireman Microphone call access different menus and to add level attenuation for each speakers zone 5 2 Software The DIVA software is designed to perform a complete configuration as well as to real time control some parameters Some software features activation can induced the corresponding front panel controls to be disabled Mostly real time controls are related to audio settings you will have control on parameters like PEQs level and filters 5 3 Event DIVA is a multi functional device that can be use with several external sources and trigger command In order to associate any action to an external command you will have to define Event Event can be compare to an action Each action or event can be started by a multiple of different ways external trigger modulation detection etc Those events are hierarchically organized by priority levels set for each one of them You also can set permanent event like playing music More information about Events can be found here Ateis International 99 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 6 Front Panel Operations This chapter will describe all the operations that can be achieved from the front panel In order to be clear as possible this chapter will be divider by theme Some operation from the front panel required an higher level than level 1 in that case you will have to enter a valid user name
84. ent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS e Do not expose the DIVA to extreme temperatures direct sunlight humidity or dust which could cause fire or electrical shock hazard e Keep away water or other liquids from the DIVA Otherwise fire or electrical shock may result e Connect the power cord only to an AC outlet of the type stated in this Owner s Manual or as marked on the unit Otherwise fire and electrical shock hazard results e When disconnecting the power cord from an AC outlet always grab the plug Never pull the cord A damaged power cord is a potential risk of fire and electrical shock hazard e Avoid touching power plugs with wet hands Doing so is a potential electrical shock hazard e Take care for correct polarity when operating the DIVA from a DC power source Reversed polarity may cause damage to the unit or the batteries e Avoid placing heavy objects on power cords A damaged power cord is a fire and electrical shock hazard e Do not cut scratch bend twist pull or heat the power cord A damaged power cord is a fire and electrical shock hazard Ask your ATEIS dealer for replacement e Turn off immediately the unit remove the power cord from the AC outlet and consult your ATEIS dealer in any of the following circumstances e Smoke odor or noise getting out of the unit e Foreign objects or liquids get inside the DIVA e The unit has been dropped or the shell is damaged e The
85. er parameters to suit your needs MODE EEE Threshold ae ess HI cm 1 eg o Type here you can choose between the compressor component or the limiter o Bypass clicking on the bypass button will instantaneously bypass the compressor limiter O Soft Knee if the soft knee button is pressed the a soft knee will be applied to the compressor limiter instead of a hard knee o Compressing in case of compressor this will indicates if the compression is acting or not o Limiting in case of limiter this will indicates if the limiter is acting or not o Ratio Comp x 1 here you can specify the compression ratio either by using the slide bar arrow key or by entering directly the value in the dedicated cell Note this parameter will have no action if the filter type is set as limiter o Ratio Limiter x 1 here you can specify the limiter ratio either by using the slide bar arrow key or by entering directly the value in the dedicated cell Note this parameter will have no action if the filter type is set as compressor Ateis International 126 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS o Threshold dB here you can specify the threshold level from where the limiter or compressor will start acting o Threshold range dB here you can specify the range of level in which the ratio gradually alters from 1 1 to the value set by the ratio parameter sof
86. ers and to constant investment we are able to respond rapidly to the demands of our various markets with specific solutions and cutting edge technology We have distributors in more than fifteen countries in Europe and the Middle East with whom we have carried out major projects In choosing ATEIS you are guaranteed a trustworthy partner that can be counted on for the long term ATEIS Field ATEIS s audio systems have been installed in the following markets Railways Subways Airports High raise buildings Hotels Restaurants Shopping malls Theme parks Ateis International 5 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 Places Stadia ATEIS of worship Museums Industrial buildings Industrial plants Commercial buildings 1 2 Contact Ateis International S A Chemin du D vent 1024 Ecublens Switzerland Phone 41 0 21 881 25 10 Fax 41 0 21 881 25 09 Mail info ateis international com http www ateis international com 1 3 Installation DIVASM Package Content Opening the box you should find the following items DIVA Master Unit Rack rounting brackets 2 pcs Metal screws Philips M3x6 6 pcs 12 way euroblock connectors 1 pcs 10 way euroblock connectors 3 pcs 5 way euroblock connectors 2 pcs 4 way euroblock connector 11 pcs 230V 24 VDC power supply CD ROM Fireman Microphone If you realize anything missing please contact
87. es at this format Ateis International 57 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 Look in B Message Lib Alarm DE Chime 3 notes T Documents and Salas vacuation EM est SP D LA D LA Mes documents es Poste de travail d Favoris r seau Mle name Ir Files of type wave File Cancel By using the Import Export buttons on the Message Library page you are able to import and export complete message library After adding messages from the library to the message manager the procedure to store them into DIVA is as follow e tick the messages you want to store and specify wheather they are security messages or not e Click Store to start the store process Once messages are stored into DIVA you can adjust independantly their level Follow the next few steps Click on the level field With arrow keys adjust the level Clicking the Play button will start playing the message at the current level see below Clicking the Stop button will stop playing the message Clicking the Save Level button will save the current message level 8 17To Set Speaker Parameters Settings The speaker parameters setting allow to route to the PSS internal speaker and to the DIVA internal Speaker music sources mic line and messages In order to route those different devices go on the Master window and tick the corresponding sources to be route to the DIVA and or the PSS Ateis International 58
88. esponding trigger Coexist mode allows the lowest priority event to keep going in the non common zones while the highest priority event is active The chronogram on figure 1 describes the process for coexist mode situation Event 1 lowest priority zone 1 2 3 and 4 conflict mode coexist Event 2 highest priority zone 3 and 4 conflict mode whatever Ateis International 142 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 Event 1 Event 2 Zone 1 Zone 2 Zone 3 Zone 4 Figure 1 Chronogram for Coexist mode with 2 common zone Cancel All mode when the highest priority event overwrites at least one zone of the lowest priority event the lowest priority event will be totally deactivated while the highest priority event is active The chronogram on figure 3 describes the process for cancel All mode situation Event 1 lowest priority zone 1 2 3 and 4 conflict mode Cancel All Event 2 highest priority zone 3 and 4 conflict mode whatever Goen J Le Goen L__t____ ret JL SJ Le zone LF T Le Zone 3 Zone 4 L Figure 2 Chronogram for Cancel All mode for 2 common zone Special case e 3 events Figure 3 In coexist mode Event 1 priority 20 zone 1 and 2 coexist mode triggered by logic in Ateis International 143 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS Event 2 priority 10 zone 2 3 and 4 coexist mo
89. essages stored in DIVA right one Here is a list of buttons and their corresponding function e Select All allows to instantaneously select all the messages from the list e Select None instantaneously deselect all the selected message Ateis International 56 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 MSG Manager will open the message manager Store Stores permanently the selected messages into DIVA s memory e Delete deletes selected messages from the store list Read reads messages stored into DIVA unit Delete deletes messages from DIVA memory Select All allows to instantaneously select all the messages from the list Select None instantaneously deselect all the selected message To add messages to DIVA you need to access the message manager Library by clicking on MSG Manager The message manager window will prompt see below Message Library m E Message Va Iroma Size Sample Rate Chime 3 notes WA AMEN SEKR 16kHz Alarm DE wa NY 7r 23kB 16kHz Evacuation EN waw AWAY 239 95k 6 16kHz Test DH way W 212 14kB 16kHz Select the message by ticking the square at their left and by clicking the Add to Diva button In the message library window you can add and delete messages Clicking the Add button will open a new window see below In this window you can select any wave file to be a message Note Only 16 kHz 16 Bits format will be stored DIVA can handle up to 45 minutes of messag
90. fy if this event is a security one or not See Common Option to learn more about the security option Next Event here you can select the event to start after the current on is finished Active at Start Ticking this option allows user to close an output contact Logic Output channel in two different manner Static will close it until the event stop and Pulse will generate a closing pulse whose length can be defined from 50 to 60000 ms Active at Stop This option is used to create a closing contact pulse when the event is finished The length of the pulse can be defined from 50 to 60000 ms To learn more about output relay please read the How To Use Output Relay Ateis International Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 Music Source here you can choose the music source you want to switch on off Zone Selection here you can specify the zone s where the music will be played and stopped ATEIS i 8 18 3 15 Security Mode In order to be compliant to standard and to save energy DIVA has to working mode Normal and Security Normal normal mode is when DIVA is supplied by the electricity network In normal mode any type of event could be started Security security mode is when DIVA is supplied by backup batteries after a power supply failure In security mode only security event could be started Music is automatically desactivated This have been made to save energy and to increase DIVA worki
91. ifier Monitoring The amplifier monitoring tabs are separated for music and voice amplifier however controls and displays are identical This is why only the voice amplifier monitoring will be presented Monitoring Eg Tone Generator 0 00000 Get Reference Reset Reference Reset Monitoring Reference unloaded displays the reference taken as open line gain Reference fully loaded displays the reference taken as charged line gain Tolerance here you can specify the value of the tolerance wherein measurement has to stay before generating a fault state Measure displays the measure of the amplifier current gain Get Reference this button start the get reference process on the amplifier Reset reference this button allows to reset all reference stored Reset Monitoring this button allows to reset the monitoring in case of maintenance The gain value are absolute gain A gain of 100 correspond to a gain of 40 dB 8 26 Use The Scheduler To access the Scheduler window go on the menu View gt Scheduler The window below should appear Ateis International 112 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 F Scheduler Master Master n Enah Oecurence 7 ame nable z arge Start Time Master this indicates the device on which the scheduler task will happen ID displays the ID number of the task Name display the scheduler task name This name can be entered in the scheduler task wi
92. increase music source 1 level simply press the Music1 level key To decrease music source 1 level simply press the Musici level key 8 21 5 From Logic Input Like with the PSS music sources routing can be operate by external trigger that means with the help of the logic evacuation or even external fault inputs In order to access the logic inputs menu go on menu View gt Logic Inputs The Logic Inputs page will pops up see below Ateis International 01 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 Logic Inputs Normal Logic Inputs S Evacuation Inputs External Fault Inputs gr Normally Close 0penj Latch Mode Channel 1 Normally Open Start Channel 2 Normally Oper Start Channel 3 Normally Oper Start Channel 4 Normally Oper Start Channel 5 Normally Open Start Channel 6 Normally Open Start Channel 7 Normally Open Start Channel 3 Normally Open Start DIVA Machine Master 1 To learn more about the Logic inputs see How to Use Logic Inputs The idea is to use logical trigger to start an event Event type for operation on music are listed below You can find more information on those events in the chapter How To Use Events Music On Music Off Music On By Zones Music Off By Zones Toggle Music On Off Toggle Music On Off by Zones In order to associate a event to a logic input trigger click on the Start button under Event Setting The Events Selection window will be open see
93. key is used as the front panel select button You have to select the music source before you can route it to some zones Note this key is not a music source toggle type you will have to create two music source selection key in order to be able to route both sources e Route The ROUTE key act exactly as the front panel route button It is the way to validate a music source and zone selection e Music Level Music Level From the PSS you can create keys to control the music sources level The Key created that way is affiliated to one source So for Controlling both sources level you will have to create four keys two for source one and two for source two f Key Setting E E Example 1 procedure to route music source 1 to zone 2 4 and 6 and music source 2 to zone 3 5 and 7 Create Zone Selection key type for zone 2 3 4 5 6 and 7 Named them accordingly Create a ROUTE key Create two Music Sources Selection keys Named them Music 1 and Music 2 Store your configuration into DIVA To route Music 1 in zone 2 4 and 6 press the Music 1 key then press the zone 2 4 and 6 and finally press the ROUTE key e To route Music 1 in zone 3 5 and 7 press the Music 2 key then press the zone 3 5 and 7 and finally press the ROUTE key Example 2 procedure to increase and decrease music source 1 level e Create a Music Level key and a Music Level key Named them Music Level and Music1 Level e To
94. ly playing To learn more about output relay please read the How To Use Output Relay Conflict you can choose between Cancel All or Coexist Pre Chime Before a call you can add a chime message Here if Pre Chime Enable is selected you can select which message will be used as pre chime Pre define Zone if ticked you can choose pre defined zone with the zone selector Zone Selection here you can specify the zone s where the call will be played 8 18 3 8 Music On The Music On event allows to start music source 1 or 2 with any type of trigger Music sources will start playing in pre defined zone s chosen in the Music Event window Music On Event Type Music Un Priority 20 Zem equals highest Mame Event g Attrib Security Next Event None Active at Start Active at Stop Logic Output Logic Output Channel Channel SEN Length Music Source Music 1 Type display the type of event you are creating or modifying Name here you can specify a name for the event created Default is Event X Priority here you can adjust the priority of the event 20 is the lowest O is the highest Attrib here you can specify if this event is a security one or not See Common Option to learn more about the security option Next Event here you can select the event to start after the current on is finished Ateis International 72 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS Active at Start Ticki
95. nd Phone 41 21 881 25 10 Comp Limiter 8 30 Use Preset 8 31 Use Output Relay Will soon be available In some windows of DIVA software you will have the possibility to set an action for output relay and or to enable busy relay or acknowledgement relay Referring to the picture below the upper squares are for output relay activation and the lower squares for acknowledgement and busy relay states Active at Start Active at Stop Logic Output N one selected Logic Output None Spiel ed Channel Channel el Static We Length E Gate Length Il m a a UIE r me Enable ACK Relay Enable Busy Relay Master Master 1 Master Mash Slave Slave Logic Output Logic Output Channel Channel e Active at Start Ticking this option allows user to close an output contact Logic Output channel in two different manner Static will close it until the event stop and Pulse will generate a closing pulse whose length can be defined from 50 to 60000 ms e Active at Stop This option is used to create a closing contact pulse when the event is finished The length of the pulse can be defined from 50 to 60000 ms Ate s International Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 129 ATEIS A e Enable ACK Relay here you can set the closing
96. ndividual privileges e Logout Opens the User Login window 7 2 5 Operation Here you can find all data communication commands Ateis International 23 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS Set Date Time Allow user to set the time and date of the DIVA unit Set Store Password Offers a store process protection password management Compile Compiles the current configuration and displays eventual errors Store Upload configuration parameter into the DIVA s parameter memory Reverse Downloads the DIVA configuration in the computer Connect Establishes data connection to the machine s in order to monitor or adjust parameters online Disconnect Disconnects DIVA software from the machine s Audio Enable Enables DIVA s audio processing Audio Disable Disables DIVA s audio processing Stop All Events Stops all running events 7 2 6 Tools Here you will find command related to communication with DIVA units Lock Window Device Search WI e Update Will update the DIVA Firmware to the one corresponding to your current software version NOTE Upgrading from a too old version to the current one could cause configuration files compatibility issues e Device Search Will search and display all the DIVA Master IP connected to the TCP IP network Language Allows user to change the software language e Options Will open the Options window in which you will be able
97. ndow Enable indicates if the task is enable or not ticked means enable Occurrence under the occurrence display you will find all information about the type of event and the way it will be triggered o Type displays the type of the task single or cycle Single is a task that will only happen once cycle could be a repeating task see below under how to set a task o Repeat displays if the task is repeated daily weekly monthly or a single task o Start Time displays the time at which the task starts o End Time displays the time at which the task stops Note if the task is a Single task start time and end time will be the same e Target display which event is affiliated to the task Select All allows to instantaneously select all the tasks from the list Select None allows to instantaneously deselect task selected from the list Del allows to delete selected task from the list Add allows to add a new task to the scheduler Edit allows to edit one task parameters Close close the scheduler window How to set a task To add a scheduler task click on the Add button in the scheduler window Then the Scheduler Task window will pops up Ate s International 113 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 Scheduler Task Name Scheduler Task 1 Occurence e Singl Enable Enable Ingle Trigger Event ID Hame Priority i Security UD Name Priority Security Start Time juillet 2008 juillet
98. ng state under batteries In order to fit the event philosophy you can force DIVA to enter the security mode with the Security Mode event Be carefull when using such an event all non security event will be unavailable Security Mode Event Type security Mode Priority 20 2 Zero equals highest Name Event 15 Attrib w Secunt Not Accessible Mest Event None Type display the type of event you are creating or modifying Name here you can specify a name for the event created Default is Event X Priority here you can adjust the priority of the event 20 is the lowest 0 is the highest Attrib not accessible Next Event here you can select the event to start after the current on is finished 8 18 3 16 Stop All Events This event has been design in order to stop event that are currently running in the system with one trigger action Stop All Event Type Stop All Event Priority 20 ero equals highest Name Event 16 Attrib Security _ Next Event None e Type display the type of event you are creating or modifying e Name here you can specify a name for the event created Default is Event X e Priority here you can adjust the priority of the event 20 is the lowest O is the highest Ateis International g0 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 e Attrib her ATEIS e you can specify if this event is a security one or not See Common Option to learn more about the security
99. ng this option allows user to close an output contact Logic Output channel in two different manner Static will close it until the event stop and Pulse will generate a closing pulse whose length can be defined from 50 to 60000 ms Active at Stop This option is used to create a closing contact pulse when the event is finished The length of the pulse can be defined from 50 to 60000 ms To learn more about output relay please read the How To Use Output Relay Music Source here you can choose the music source you want to switch on 8 18 3 9 Music Off The Music On event allows to stop music source 1 or 2 with any type of trigger Music sources will stop playing in pre defined zone s chosen in the Music Event window Music Off Event Type Music Um Priority 20 2 ero equals highest Mame Event 10 Attrib Security Next Event None Active at Start Active at Stop Logic Output Logic Output Channel Channel vegan Length Music Source Music 1 Type display the type of event you are creating or modifying Name here you can specify a name for the event created Default is Event X Priority here you can adjust the priority of the event 20 is the lowest 0 is the highest Attrib here you can specify if this event is a security one or not See Common Option to learn more about the security option Next Event here you can select the event to start after the current on is finished Active at Start Ticking this option allows user t
100. nt created with the logical input In order to do so tick the square selector and click on insert Note you can associate more than one event to an external trigger as well as creating event sequences To learn more about it please read this When logic input have set for Mic Line source you can find a list of logic input associated to Mic Line source on the Mic Line window in Logic Input drop down menu Ateis International 104 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 Normal Input Channel 1 Paging 8 23 3 From Software The DIVA software allows to control and monitor Mic Line source Once you have enter the Mic Line window by double clicking on the Mic Line icon you will be able to read and control some parameters right part of the window see below Mic Line level controls Mic Line mute controls Mic Line overflow indicators Mic Line signal presence indicators Mic Line volume indicators Mic Line Ateis International 105 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS 68 24 Use Logic Inputs Logical inputs is a way to start any type of event with an external trigger They are separated in three different types Logic Inputs Siz Ed Normal Logic Inputs Evacuation Inputs gt External Fault Inputs Channel 1 Normally Open Start Channel 2 Normally Open Start Channel 3 Normally Oper Start Channel 4 Normally Oper Start Chann
101. nt version Double click the new software version icon Follow the installation process Ateis International Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 18 4 External Devices This chapter will quickly describe the external devices that could be connected to a DIVA unit It won t speak about external contact or button that also could be used For more information about those devices please visit ATEIS website 4 1 Fireman Microphone The Fireman Microphone SHM 1 is a small compact microphone dedicated to security calling It is a totally monitored microphone with internal resistor network to detect four different states Shortcut Closed Contact Open Contact Absent Firemen Microphone SHM 1 for All call group or zone calls The EN 60849 surveillance is realised thanks to the DIVA SEC interface 4 2 PSS The PSSDT paging microphone can be configured either using a PC computer or by using control keys and the front LCD screen of the SINAPS module to which it is connected Access can be password protected All parameters needed for site operating can be programmed zones assigned to the different buttons name of zones zone groups priorities access to different messages levels adjustments pre call chime press to talk music ON OFF and music routing lts large LCD screen provides an overall view of busy zones and active sources A VU meter controls the microphone presence and modulation le
102. nual E e Version Shows the software version and checks the DIVA unit embedded version See below Ateis International 35 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 E Version Software 1 0 0 10 1 0 0 Firmware FPGA N et Card About Opens a information windows about copyrights software release version etc User Manual Opens the complete help user manual 7 3 Toolbars In the DIVA software the different toolbars offers shortcut to main menu items Here are the list of them from left to right and up to down New Project Opens a new project Open Opens existing project Save Saves current project Print Opens the print preview window See How to print project to learn more about the printing options Cut Cuts out the active selection and copies it to the operating system s clipboard Copy Copies the active selection to the operating system s clipboard Paste Pastes the content of the operating system s clipboard Delete Deletes the active selection Undo Will undo the last actions Redo Will redo the last actions or will retrieve the last state in case undoing too far Cascade Cascades the current opened windows Tile Tiles the screen with the current opnened windows Arrange Icon Arranges Icons in a window where possible Lock Locks the software Note if no password wer
103. o close an output contact Logic Output channel in two different manner Static will close it until the event stop and Pulse will generate a closing pulse whose length can be defined from 50 to 60000 ms Active at Stop This option is used to create a closing contact pulse when the event is finished The length of the pulse can be defined from 50 to 60000 ms To learn more about output relay please read the How To Use Output Relay Ateis International 73 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS e Music Source here you can choose the music source you want to switch off 8 18 3 10 MIC LINE Paging Mic Line Paging Event Type Mic Line Paging Name Event H Active at Start Logic Output None selected Channel Slave Logic Output Hone selected Channel Conflict e Cancel All Coexist x Friority ero equals highest Attrib Security Active at Stop Logic Output None selected EN Channel Length ms Enable Busy Relay Logic Output None selected Channel Bee ARE E Pre define one Pre detine one Enable Master 1 Masher more about the security option Type display the type of event you are creating or modifying Name here you can specify a name for the event created Default is Event X Priority here you can adjust the priority of the event 20 is the lowest O is the highest Attrib here you can specify if this event is a
104. ol window e System Status Calls the PPM Chime control window for assigning pre and post announcement chimes e Event Calls the Logic In control window to edit and monitor TTL input properties e Message Calls the Logic In control window to edit and monitor TTL output properties e Scheduler Calls the Logic In control window to edit and monitor analog control input properties e GPIO List Calls the Subpreset Elements control window to monitor parameters registered with the current subpreset e LCD Calls the Remote device List where you can search for and register URCs or PPMs in the system Ateis International 39 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS View User Operation Tools Lock Wir Message Scheduler SPIO LED Language Toolbars d Compile Preset Contral Lock Design Help Windows e Toolbars Within this menu subgroup you ll find the commands to call closed or hidden toolbars or floating toolbox items gt Edit gt Compile gt Preset gt Control gt Function Link gt Help gt Windows Manager 7 2 4 User Here you are able to manage the user right add users with a password and restrict access only to needed features Operation Tools Le User Management Logout e User Management Calls the User Management window to set up users or user groups and their i
105. ols Lock Window Help 2 ec ARR n EIE System DIVA System Audio Source Audio Component Note Drag DIVA devices here wl A Master 1 Connection Fault Ur ES emm B Evac 0 Modified Not compiled Izeg 3 7 7 Property Control Section DRE CU In this section you can find several control windows docked together into a sliding control panel You can look at the different control windows by bringing the cursor over their tabs at the bottom of the very bottom of the main window The corresponding control window will slide up allowing you to quick examine or quick modify settings without selecting it from the Menu Bar The control panel will automatically slide down again if you move the cursor out of it s space giving again the whole view to the Design View Area The two accessible sub bar windows are listed below e System Status Gives access to Log files management as well as project build historic System Status Log 2 ould Fe Export Log FA Delete Log Patesouy a a Ateis International 39 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS O e LED Display offers real time status LED display only if connected to DIVA units It is a replic of the front panel LED display CAES a Evac alam Test so s 1 2 3 4 8 6 7 fe aix e a E a Ca La j ia 08 Fault Alarm SP Paging M Music 7 8 Stat
106. ot use benzene thinner or chemicals to clean the DIVA Use only a soft dry cloth e lf the DIVA is moved from a cold place e g overnight in a car to a warmer environment condensation may form inside the unit which may affect performance Allow the DIVA to acclimatize for about one hour before use Ateis International 9 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS 2 Hardware Description DIVA s conception lead to a very intuitive front panel as well as very complete connection solutions on the back panel In the next four paragraph the DIVA8M S front panel and the rear panel connection board are detailed Ateis International 10 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 2 1 DIVAS8M Front view Fower Fault and Evacuation LED Menu one Event Indic ator Indicators Navigation LED Buttons Monitored Fireman Microphone Input Music Source Message Selection Buttons Attenuator Selection uttons and Indicators Enobs Buttons Ateis International Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 2 2 DIVA8M Rear view Ethernet Monitored Connector for FE External Control Fireman Microphone Network Input Connector to DIVASS op Front Panel EN EE Deportation ec he EXTERNAL FIREMAN MICROPHONE ETHERNET POR LINK OUT MUSIC INPUT ge Ke AN D REMOTE EXT Logical Inputs and External Faults Inputs
107. output contact Logic Output channel in two different manner Static will close it until the event stop and Pulse will generate a closing pulse whose length can be defined from 50 to 60000 ms Active at Stop This option is used to create a closing contact pulse when the event is finished The length of the pulse can be defined from 50 to 60000 ms To learn more about output relay please read the How To Use Output Relay Music Source here you can choose the music source you want to switch on off 8 18 3 14 Toggle Music On Off By Zone The Toggle Music On Off By Zone event have been created to turn music on or off with one same trigger in some zones As example using a contact one closing will switch on music one more closing will switch off music in pre defined zone s Ateis International 78 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 Toggle Music By Zones Event Type Toggle Music On Off By Name Event 14 Next Event None Active at Start Logic Output Channel Length Music Source Music 1 Master 1 All Master alfa AEEEORES Priority ZU ero equals highest Attrib Security Active at Stop Logic Output Channel Length Type display the type of event you are creating or modifying Name here you can specify a name for the event created Default is Event X Priority here you can adjust the priority of the event 20 is the lowest 0 is the highest Attrib here you can speci
108. perations gt Compile or Click on the Compile icon in the compile toolbar view picture below or even type F9 On the Status Bar you can permanently see the compile status of your project e Compiled means the current state of your project have been checked e Not Compiled means that your current project has not been checked 8 10Store The store command menu Operations gt Store or the Store shortcut or even F8 open the store window see below Ateis International 51 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 To start storing click on the Store button A timeline display the status of the process The different state of the store process are written in the Store Status Area If not already log in DIVA software will ask you to enter a valid user name and password Once the store process is finished you will be prompt to e Connect to DIVA choose Yes or No e Enable Audio on DIVA choose Yes or No 8 11 Reverse The reverse command allow to download from DIVA to the software the current configuration stored into DIVA e To start the reverse process go to the menu Operations gt Reverse or use the Reverse Shortcut on the compile toolbar e Click Reverse you can follow the advancement of the process on the timeline display The reverse window will be open see below Ateis International 52 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 Reverse
109. ponding EVAC LED s should light s up Note If the fireman microphone paging event has pre defined zones pressing the microphone button will start a call in the pre defined zone In case of doing a call in manually selected zone the next microphone call will take place in the pre defined zones after a adjustable delay see How To Use Fireman Microphone Ateis International 98 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS 7 DIVA Software Presentation The chapter will introduce to you the DIVA software This is a visual presentation in order to let you know where you can find the needed tools After installing the DIVA software you can access it e Either by double clicking on the Desktop icon ATEIS DIVA 1 0 0 D tai 10 e Or by start gt program files gt Ateis gt ATEIS DIVA v1 x x The DIVA software starts with no file loaded and a blank worksheet looking as follow File Edit View User Operation Tools Lock Window Help Deels RO Xs ai nAn if a e RS Le LE de A Preset System g x D DIVA System Audio Source Audio Component Connection J Fault B Evac Erectus aS Startup View Elements 1 Title Bar Displays the path name of the active file 2 Menu Bar Holds the main menu commands arranged into functionality groups 3 Toolbars Toolbar items act like a shortcut to their corresponding menu command At
110. possibility to force DIVA to enter his security mode For more information about security mode please read this The external trigger of those inputs should come from security devices such as security power supply You can also use those input to force DIVA into the security mode in order to save energy during night Like any of the logic inputs you can associate an event to External Fault Inputs Logic Inputs Normal Logic Inputs 5 Evacuation Inputs External Fault Inputs Name Normally Close Open Event Setting Channel Normally Open Channel 2 Normally Oper DA Machine Master 1 Name Here you can specify a name by simply clicking in the box e Normally Close Open Here you can specify the behaviour of the inputs Normally closed means that the contact is closed in neutral position and reciprocally normally open means that the contact IS open in neutral position e Event Setting By clicking start you will be able to associate an event to this input see this to learn more Ateis International 109 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS 8 25 Use Monitoring In order to activate zones monitoring and or amplifiers monitoring double click on the monitoring button under DIVA icon in the master window see below sh Master 1 Note Drag Audio sources here Speaker Parameters Setting Machine P55 Music 1 Enable Di BR Front Panel res LL Wic
111. power cord is damaged If you continue using the DIVA fire and electrical shock may result e Do not drop or insert metallic objects or flammable materials into the unit as this may result in fire and electrical shock e Do not remove the DIVA s cover as there are exposed parts inside carrying high voltages that may cause an electrical shock Contact your ATEIS dealer if internal inspection maintenance or repair is necessary e Do not try to make any modifications to the DIVA This is a potential fire and electrical shock hazard e Avoid the DIVA s ventilation slots to be blocked Blocking the ventilation slots is a potential fire hazard Caution This sign indicates a potentially hazardous situation that can result in moderate or minor personal injury and or property damage e To prevent the unit from falling down and causing personal injury and or property damage avoid installing or mounting the unit in unstable locations e Leave enough space above and below the unit to provide good ventilation of the DIVA If the airflow is not adequate the DIVA will heat up inside and may cause a fire e Operate the DIVA in an environment with a free air temperature of between 0 C and 40 C 32 F and 104 F e Turn off all audio equipment when making any connections to the DIVA and make sure to use adequate cables Ateis International gQ Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS e Do n
112. rated front panel speaker level to avoid high level disturbance Use arrow keys to access the Speaker Level menu Press OK Adjust the level with the or arrow keys Press ESC to go out of the menu 6 1 7 Log files In the menu section of DIVA you read the Log File as well as delete it if needed Use arrow keys to access the Log Files menu Press OK Use arrow keys to access DELETE submenu If you want to delete the Log Files Press OK It will ask you Are you sure to delete Log Files If Yes Press OK If No Press ESC Use arrow keys to go on the VIEW submenu Click OK Use arrow keys to display different Log Files information Press ESC to go out of the menu 6 1 8 Mic Line With this menu you can adjust the level of the external microphone or the third music source e Use arrow keys to access MIC LINE menu e Press OK e Adjust level either with or arrow keys e Press ESC to go out of the menu Ateis International 25 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 6 1 9 Stop All Events From the front panel of DIVA you are able to stop all the running events events are discussed in How to use events Use arrow keys to access the STOP ALL EVENTS menu Press OK it will ask you Are you sure to Stop all events If yes Press OK If no press ESC Press ESC to go out of the menu 6 1 10 Ethernet Settings From the front panel menu you can set all parameters concerning the network
113. rce window see below Music sources routing can be managed from front panel from PSS and from logic input You can also use real time control and indicators in order to adjust the music sources level to mute sources independently and to check music sources status See the following chapter to learn more Ateis International g5 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS Use Music Source From Front Panel Use Music Source From PSS Use Music Source From Logic Input Software Control Music Source Music 1 The Music Source main window allows user to select in which mode the music sources are used You can find e Modulation Detection The modulation detection mode is like the VOX mode It allows you to activate a source as soon as a certain amount of signal is detected e Permanent Permanent mode allows to set up both music sources routing It will deactivate all the front panel music controls e Logic Input Using music from logic input allows user to manage external trigger to control the routing of music sources e Route Key The route key mode will activate all the music button on the front panel It has to be used when music should be controlled directly from the machine Ateis International 26 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS _ i For all those different mode you will have to set up the music sources setting b
114. ress OK if you accept the changes 6 1 4 IP Address The IP address Internet Protocol Address is a common way of using an address in order to identify and communicate into a computer network This IP address is mostly used to be a locator to a device in order to communicate with it This is most frequently an unique address into a specific network This address can be seen and modified see How to Set IP Address e Use the arrow key to access the IP Address menu e Click OK you will see the current IP address Ateis International 24 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 Press ESC to go out of the menu 6 1 5 Set time On DIVA front panel you can set the current location time format as well as the current date and time Use arrow keys to access the set time menu Press OK Use the arrow keys to access the format submenu Press OK you will have the choice between the 24 hours format or the AM PM format Select the one you need Press OK Use arrow keys to go to the Time Data submenu Press OK you will see the date and time stored into DIVA Data and time are display as follow Month Day hour minutes second Use the arrow keys to go on the number you need to change Use or keys to adjust the number value Press OK you will be prompt to validate the time data changes Validate the Time Data changes Press OK Press ESC to go out of the menu 6 1 6 Speaker Level You can adjust the integ
115. rrent message or event and to retrieve it as soon as the one with a higher priority has finished e Pre Chime the pre chime option allows to play a chime message before each call You can choose the chime message using the drop down menu e Pre define Zone by ticking this option you will be able to select pre define zone in which the call will be made Pre defining zones don t disable the front panel zones selector As soon as a call in Ateis International 84 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS non pre defined zone is finished the next call will be automatically rerouted in the pre defined zone after the amount of time set in the fireman microphone main window e By clicking Ok you will validate your settings Cancel will annulled the current settings Advanced Settings Priority 0 Active at Start Logic Output Channel Length Enable ACK Relay Master Slave Logic Output Channel Conflict Fre Chime ero equals highest Attrib Active at Stop Logic Output Channel Length Enable Busy Relay Master Slave Logic Output Channel e Cancel All Coexist Pre Chime Enable Pre detine one Pre define one Enable Al Alta 2tata sltet7 e 8 21 Use Music Source In order to use music sources first drag and drop music source from the Design Component Section to the Master window Double click the music source Icon to enter the Music Sou
116. s Switzerland Phone 41 21 881 25 10 8 18 3 3 Command String With this event you can send by RS232 commands to third party devices Valid commands are described in the Communication Protocoles chapter Command String Event p Type Command String Priority Holoceen DE Name Event 5 Attrib Security Next Event N one Command Pot Number e Type displays the type of event that is created in this case Load Preset e Name here you can specify a name for the event created e Attrib here you can choose between security event or not See Common Option to learn more about the security option e Next Event you can specify an event that will be started as soon as this event has finished e Command here you can type in the command to send e Port Number here you have to specify on which port the command have to be sent 8 18 3 4 Stop Event This event have been created in order to be able to stop any event by the means of a trigger Stop Event Event Type Stop Event Priority 20 Zer equals highest Name Event E Attrib Security Next Event N one E top E vent N one e Type displays the type of event that is created in this case Load Preset e Name here you can specify a name for the event created Ateis International 67 Ch du D vent 1024 Ecublens Switzerland Phone 41 2
117. s reference for A and B in parallel Connected Source display the source connected to one zone Voice Amplifier Music Amplifier VO3 e Tolerance here you can specify the tolerance wherein measurement has to stay before generating a fault state Measure Ohm displays the real time measurement of A and B in parallel e Diff displays the difference in percent between Reference A B and Measure Zone Monitoring Controls e Monitoring period When using attenuator values like 12 16 and 20 dB you have to specify a monitoring period in order to avoid issues To learn more about that point please read this Get Reference this button start the get reference process for one zone at a time Get all Reference this button start the get reference process for all zone Reset Reference this button allows to reset all reference stored Reset Monitoring this button allows to reset the monitoring in case of maintenance Tone Generator this button allows to set the tone generator settings You can learn more about tone generator by reading this Procedure to make references for one zone please follow the next steps e Select a zone by clicking on the corresponding line e Press the Get Reference button e Choose a tolerance value Ateis International 111 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 Procedure to make references for all zone please do so e Press the Get All Reference 8 25 2 Ampl
118. sing of a Logic Output Channel relay as soon as zones where an event has to be played are freed from higher priority events e Enable Busy Relay here you can specify an Logic Output Channel relay that will be closed as soon as you will trying to speak in zones where a higher priority event currently playing To learn more about output relay please read the How To Use Output Relay e Message by using the drop down menu you can select in the list of stored message a message to assign to the event e Play Mode by ticking continous the message will be played until a trigger happen Conflict you can choose between Cancel All or Coexist Repeat Time if continous not ticked you can choose a number of time this event will be repeated e Zone Selection here you can specify the zone s where the message will be played 8 18 3 7 Fireman Mic Paging A Fireman Mic Paging event can be declare in order to be used with any type of trigger The one that can be declared in the Fireman Mic window Ateis International Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 70 Fireman Mic Paging Event Type Fireman Mic Paging Name Event Active at Start Logic Output Channel Length Enable ACK Relay Master Slave Logic Output Channel Friority ZU ero equals highest Attrib Security Active at Stop Logic Output Channel Length Enable Busy Relay Master Slave Logic Output Channel Conflict e
119. speaker You can adapt PSS speaker level to your desire Note Speaker Level and Speaker Level are two distinct keys e Event Start Event Stop Those two keys are an additional way of starting and stoping events that are not selected in the message section please read this You can start and stop any kind of event Please be careful to the fact that you will need a stop event key for each start event key for play message type of event When creating an Event Start Stop key you will have to select in the existing event list the one to associate to the key D Key Setting Hone e Push To Talk Microphone Call The Push To Talk Microphone Call key allows to change the behaviour of the microphone call The default behaviour for the microphone Mic Key is the locked to talk To use this key in order to make a microphone call you will have to keep your finger on the key while speaking e Push To Talk Chime Call The Push To Talk Chime Call key has to be used like the Push To Talk Microphone Call The difference is that for each call a pre chime message will be played Note don t forget to load a chime message in the general PSS page e Jump To Page When using a PSSXXDT that has over 12 keys it could be really helpful to create key that allows to jump from page to page As soon as you select the Jump To Page type of key a page selection window will pops up please select the page where you want to jump 8 Key Setting ig m
120. t knee function either by using the slide bar arrow key or by entering directly the value in the dedicated cell Response time 10ms here you specify the attack time for the compressor limiter Recovery time 10ms here you can specify the release time for the compressor Limiter Gain reduction dB indicates the current amount of gain reduction Graphic by clicking on the graphic button this will open the Compressor Limiter graphic edition window see below You can adjust the compression ratio by moving the red cursor the threshold level by moving the blue cursor and the threshold range with the yellow cursor OO 0 0 Comp Limiter e Double click on the compressor limiter icon the compressor limiter window pops up see below Adjust the Compressor Limiter parameters to suit your needs Ateis International 127 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 Comp Limiter MIC Line o Bypass clicking on the bypass button will instantaneously bypass the compressor limiter O Soft Knee if the soft knee button is pressed the a soft knee will be applied to the compressor limiter instead of a hard knee o Compressing this will indicates if the compression is acting or not o Limiting this will indicates if the limiter is acting or not o Ratio Comp x 1 here you can specify the compression ratio either by using the slide bar arrow key or by entering directly the value in the dedicated cell Note
121. t the microphone see the lower picture Note the front panel connector and the back connector are parrallel connected Please only use one of them ei oi mma o O sacumon O aen Z ICH ae age EXTERNAL FIREMAN MICROPHONE ETHERNET PORT LINK OUT MUSIC INPUT de eretd i t D D 1 D D Sab dtg ddd jad jjda jabo daba ije LO Ou US E z E L oo 1 l S l FS D D Do Dog ZONE ZOE ZONES ZONES LOMES ZONEG ZOHET ZONES 1 3 GAIN MIC LINE PSS PSM RSS REMOTE EXT 4 8 33 3 PSS Microphone In order to connect the PSS microphone to DIVA simply use a shielded CAT5 cable to link the PSS PSM DIVA RJ45 connector to the RJ45 of the PSS Maximum cable length 200m if more distance is needed please use a local 24V power supply EXTERNAL FIREMAN MICROPHONE ETHERNET PORT LINK OUT MUSIC INPUT giii aii Lu ojo LJ CC ZONE ZONE2 ZONE3 ZONE4 ZONES ZONE6 ZONET ZONES GAIN MIC LINE PSM RS232 REMOTE EXT hielded CAT5 Ateis International 132 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS 8 33 4 Music Sources Connecting music sources to DIVA is easy thanks to the CINCH connections You have a left and right connection for both music sources Keep in mind that DIVA is not a stereo player all music sources are processed in mono t 6 S625 EEEZEEBE Fre Se SESESES 9255 ad a e e EXTERNAL FIREMAN SEEEEEEESs 5522 TEE 22233 12288 MICROPHONE ETHERNET
122. tion is used to create a closing contact pulse when the event is finished The length of the pulse can be defined from 50 to 60000 ms To learn more about output relay please read the How To Use Output Relay Ateis International Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 Music Source here you can choose the music source you want to switch off Zone Selection here you can specify the zone s where the music will stop playing ATEIS 8 18 3 13 Toggle Music On Off The Toggle Music On Off event have been created to turn music on or off with one same trigger As example using a contact one closing will switch on music one more closing will switch off music Toggle Music Event Type Toggle Music On Off Pricrity 20 Zero equals highest Mame Event 13 Attrib Security Next Event None Active at Start Active at Stop Logic Output Logic Output Channel Channel wegen Length Music Source Music Type display the type of event you are creating or modifying Name here you can specify a name for the event created Default is Event X Priority here you can adjust the priority of the event 20 is the lowest O is the highest Attrib here you can specify if this event is a security one or not See Common Option to learn more about the security option Next Event here you can select the event to start after the current on is finished Active at Start Ticking this option allows user to close an
123. tion under a different name Simply go to the menu File gt Save As 8 1 4 Autosave In the Options page under File tab you have the possibility to set an autosave procedure You also can set the number of recent files visible in the file menu gt recent files Ateis International 42 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 Options Network vw Autosave your design h Aubosave every 10 minutes 5 3 Recent files Tick the Autosave your design option in order to activate the autosave option Choose after how much time the autosave will automatically run Choose how many recent files would be visible in the menu file gt recent 8 2 Print Project In order to print a project you need to access the print preview page To access this page go in the menu File gt Print or click on the print shortcut highlighted on picture below in the edit toolbar Once you launch the print command you will enter the Print Preview window see below The print preview offer you the possibility to print DIVA main windows separately In case of DIVA master Network you can select which master window you want to print Ateis International Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 Print Preview T Sc Master Master 1 Items System Configuration Note Drag DIVA devices here Master The print toolbar include Print Button in order to
124. to set network parameters as well as software colour scheme and autosaved function See Pictures below 7 2 7 Lock The Lock menu allow you to lock the software with a password in order to avoid another user to manipulate your configuration Ateis International 34 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS Help Lock Window o Lock Set Password e Lock Locks the software Note if no password were specified every user can unlock the software e Set Password Offers the possibility to set a password for unlocking the software If set as soon as you press the unlock button it will prompt you to enter the last password set 7 2 8 Window This menu provides window arrangement commands and quick access to open design or component control windows ShiPt Ctrl F2 Shife Ctrl F 3 CL Arrange icons Shift Ctri F4 1 System 2 Master 1 3 Master 1 DSP Configuration e Cascade Cascades the current opened windows e Tile Tiles the screen with the current opened windows e Arrange Icons Arranges Icons in a window where possible Here you can find a list of all currently opened windows gt System gt Master 1 gt Master 1 DSP Configuration 7 2 9 Help Here you will be able to check that the software version corresponds to the one into DIVA units access to software information as well as the help user manual document Help Version About Wy User ma
125. tware you can control the tone generator parameters To access the tone generator parameters window click on Monitoring under the DIVA icon in the system window Then click on the Tone Generator button Tone Generator Sele Frequency Enable 16 Tone Hz fei e Mute here you can mute the generation of the pilot tone e Frequency Hz allows to choose between 18kHz and 20kHz pilot tone by using the drop down menu e Target Level dB allows to increase the tone level up to 10dB e Enable 1K Tone ticking this option allows to add a 1kHz signal to the current pilot tone 9 Communication Protocols COMING SOON Ateis International 140 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 10 Explanation About Monitoring Process The monitoring can be split into 2 different parts Line monitoring zones and amplifier monitoring Line monitoring is based on impedance measurement and amplifier monitoring on amplifier s gain measurement Amplifier monitoring The amplifier monitoring used a pilot tone at 18kHz or 20kKHz that is adapted to pull out 2 Vrms By measuring the output signal of the amplifier and computing it in the DSP we can adjust the level of the pilot tone The adjustment of the pilot tone is related to the amplifier gain and can directly inform us on the gain value The gain variation are measured constantly and compared to a gain references value Below you can find a bloc schematics for Voice
126. u will find the list of existing event To create a new event simply click on New under Event As soon as you click on the New button the software will ask to choose a event s type see below Master Select Master 1 Event Type Music On In order to select an event s type use the drop down menu Then click OK After you have press OK you will return to the Events Selection window To edit your new event settings select it by clicking on the right line and then click Edit Note don t click in the square selector The corresponding event s type window will pop up After your event settings are complete click OK The last step is to affiliate the event created with the logical input In order to do so tick the square selector and click on insert Note you can associate more than one event to an external trigger as well as creating event sequences To learn more about it please read this 8 24 1 Normal Logic Inputs To access the Logic Inputs window go to the menu View gt Logic Inputs Then click on the Normal Logic Inputs tab Ateis International 107 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 Logic Inputs Normal Logic Inputs 5 Evacuation Inputs LE sternal Fault Inputs d Normally Close Open Latch Mode Normally Open Channel 1 Channel 2 Channel Channel 4 Channel 5 Channel 6 Channel 7 Normally Oper Normally Oper Normally Oper Normally Open Normally Oper Normally Op
127. udio inputs Two are O dB line inputs for tuner cd player etc One gain adjustable MIC LINE inputs for using a third O dB source or an external microphone One input for PSS or PSM microphone and one fireman microphone input Built in DIVA8M a front panel fireman microphone input that is fully monitored There are eight monitored loudspeaker zones A B feed by two amplifier channel Voice and Music 1 4 3 Connectivity The DIVA master is designed to be networked with slave DIVA on RS485 using CAT5 cables The DIVA master is connected to the computer upon Ethernet protocol Third party control can be achieved via the RS232 Adding slave increase the number of zone as well as input output contacts 1 4 4 System Configuration The DIVA8M S configuration is done with the DIVA Windows based graphical design and operating environment software This is an all in one software with configurable option for each DIVA s features 1 4 5 System Control The DIVA software allows user to real time control features like PEQs filtering level adjustment But DIVA has also been defined to be a standalone device once configured The front panel offers controls like zone selection music routing zone attenuator knob message launching buttons and different indicators LED 1 5 Safety Declaration Warning This sign indicates a potentially hazardous situation that can result in death or serious personal injury Ateis International 7 Ch du D v
128. us Bar D Connection 9 Faut UN Evac IS Modified Compiled The status bar shows quick look status information about e Connection Lights up when connected to DIVA e Fault Lights up when a faults status is detect onto DIVA e vac Lights up when a Evac state is detected Additional Status Information e Timeline Shows the progress of commands like opening component control windows e Modified Indicates if the current file has been modified since last save e Compiled Indicates if the current file has been compiled Ateis International AO Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 8 How To The How To section is divided by theme Each Theme discusses about how to perform an action or multiple action in order to build a configuration The Philosophy of this chapter is that if you read it from A to Z you will be able to perform a full advanced DIVA configuration But it has been written to offer quick navigation so that you can find specific information about one theme Here under you will find a complete list of the How To topics Save Open Print Project Start a New Project Change Colour Scheme Confiqure network Options Use the User Management Enter Password Update DIVA Compile Store Reverse Add design Component Search Device Set IP Adress Perform a DIVA Master Network Add Messages Into DIVA To Set Speaker Parameters Settings Use Events Set up Front Panel Messages Use a Fireman
129. vel built in loudspeaker makes it possible to listen to all system generated messages and announcements The PSSDT console is SINAPS security system interface and is fully monitored microphone capsule power supply touchscreen audio and RS485 connections Any system faults are detected located and indicated clearly on the screen Different product references are available to suit all site sizes Ateis International 19 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 PSS849 4 zones for SINAPS Compact IDA4 PSS12DT 12 zones for SINAPS M and SINAPS XM PSS24DT 24 zones for SINAPS M and SINAPS XM PSS48DT 48 zones for SINAPS M and SINAPS XM PSS72DT 72 zones for SINAPS M and SINAPS XM PSS96DT 96 zones for SINAPS M and SINAPS XM Access to the PSS Data Sheet 4 3 PSM The PSM 8 is a 10 keys call station of which 8 are programmable with microphone integrated loudspeaker and buzzer It can be used with either IDA4 X M s or DIVA8M it is possible to add up to 11 extensions to the PSM8 increasing programmable keys number to 96 Extensions are call stations without microphone The PSMS can be cascade in order to increase the number of call station In that case the first PSMS will become a Master PSMS and the rest will become slave PSM 4 4 JB Junction Box Easy chain connection of LAP peripherals URC and PPM using standard CAT5 cables KEY FEATURES e 5x RJ45 Ateis International
130. w To Use Output Relay e Music Source here you can choose the music source you want to switch on e Zone Selection here you can specify the zone s where the music will be played 8 18 3 12 Music Off By Zone The Music Off By Zones event allows to stop music source 1 or 2 with any type of trigger in pre defined zone s Ateis International 76 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 Music Off By Zones Event Type Music Off By ones Name Event 12 Next Event None Active at Start Logic Output Channel Length Music Source Music 1 Master 1 All Master alfa AEEEORES Priority ZU ero equals highest Attrib Security Active at Stop Logic Output Channel Length Type display the type of event you are creating or modifying Name here you can specify a name for the event created Default is Event X Priority here you can adjust the priority of the event 20 is the lowest 0 is the highest Attrib here you can specify if this event is a security one or not See Common Option to learn more about the security option Next Event here you can select the event to start after the current on is finished Active at Start Ticking this option allows user to close an output contact Logic Output channel in two different manner Static will close it until the event stop and Pulse will generate a closing pulse whose length can be defined from 50 to 60000 ms Active at Stop This op
131. xcept O Storing config messages o Change Ethernet settings as well as MAC address o Update firmware To enter level 2 a password is needed e Level 3 is for specific maintenance operator and trained persons Level 3 has all the right of level 2 Store a new configuration file o Manage messages o Maintenance operation To enter level 3 a password is needed e Level 4 is for authorized by the manufacturer to either repair the unit and or alter its firmware Level 4 has all the level 3 rights o Update firmware o Repair To enter level 4 a password is needed 8 7 Enter Password For process like storing and updating you will need a username and a password see How To Use User Management There are two different way of connecting to your account from front panel or from software e From front panel When trying to attempt protected operations you will have to enter you user name and your password Use the arrow keys to select the right letter or number click OK enter the next letter or number repeating the same procedure Once you have enter the right user name press once the down arrow key to find APL Press OK this will validate you entry DIVA will ask to enter your password repeat the same procedure to enter password e From software You will be automatically login after first store update network options change ethernet settings change Effectively DIVA software will ask you to enter a
132. y clicking the Edit button for both sources When clicking on the Edit button for music source 1 or 2 you will enter the music source Advanced setting see below Note for music used with logic inputs the music sources settings have to be made with the Music Events Advanced Settings Priority 14 Gem equals highest Attrib Security Active at Start Active at Stop Logic Output Logic Output Channel Channel Length Length Pre detine one Pre define one Enable Master 1 All Master sfr 2 3 45 6 78 e Priority here you can adjust the priority of the event 20 is the lowest 0 is the highest Note be carful when setting priority for both sources conflict may appeared if both sources have the same priority level e Attrib here you can specify if this event is a security one or not See How to Use Event to learn more about the security option The output relay part is discussed in the How To Use Output Relay please read it e Pre define Zone here you can specify in which zone music will be routed Note In Route Key mode you don t have to pre define zones as everything is controlled from the front panel However you can specify zone in Route Key mode but keep in mind that the routing will only be activated for default music source OK will accept the current setting and close the window e Cancel will annulled the current settings and close the window 8 21 1 From the Front Panel On the front panel see below
133. y for both music sources Same priority for the two music sources can result in conflict 8 21 4 From PSS The PSS microphone is able to operate on music sources In order to do so you have to define PSS keys to suit your need See How To Use PSS Microphone to learn more about the PSS Note Routing music from the PSS can only be operated if the music source mode is Route Key PSS keys for music operations can be set to different type using the drop down menu see below Ateis International g9 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS ER e Zone Selection By creating a Zone Selection key you can make a selection of zones in which music will be routed Note Zone Selection keys are not exclusively for music Zone selection for paging are made the same way As soon as you select Zone Selection a new Zone Selection window will pops up In this window choose the zone s to associate to the key see below fone Selection Master 1 All Master CONRAD RES e Music Source Selection When creating a Music Source Selection key you will have to choose between music source 1 and music source 2 with the Key Setting pop up window Ateis International 90 Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS F Key Setting EX This type of
134. your distributor Rack mounting If needed fit the rack mounting brackets to each side of the DIVA by using the 6 pcs Phillips M3x6 screws supplied with the package Ateis International Ch du D vent 1024 Ecublens Switzerland Phone 41 21 881 25 10 ATEIS A Sitting The DIVA takes a 2U 19 rack space and generates little heat itself Consider leaving enough ventilation space above and below the unit Do not mount the LAP directly above heat generating devices like power supplies or power amplifiers Power connection DIVA only accepts 24 VDC power supply Use the power supply furnished with DIVA or use an external 24VDC power supply like the PS24 and connect it on a 4 way euroblock connector respecting the polarity 1 4 System Overview This paragraph intend to briefly described the main DIVA properties 1 4 1 General The DIVA8M module unit houses audio digital processing DSP a matrix a digital message player a fully monitored fireman microphone amplifiers monitoring with switchover to backup amplifier and loudspeaker lines monitoring It can process and route one PSSxxDT security microphone console or up to eight cascaded PSM paging microphones and two 0 dB audio inputs into 2 different channels Music Voice Each input is fitted with volume controls and equalizers The two audio inputs feature contact and VOX activation ideal when using the cordless microphone for example 1 4 2 Audio There are 5 a
Download Pdf Manuals
Related Search
Related Contents
Kramer Electronics VS-62H video switch Bedienungsanleitung Trübungs-Transmitter - Mettler 23350-A-10 Prem80 170 FrenchCan.qxd 3. Mesures analytiques et essais Netis System ST-3105 network switch "取扱説明書" YOUR PO49X PIZZA OVEN CONNECTING TO POWER Samsung SNV-3082 surveillance camera Copyright © All rights reserved.