1. IP Address 192 168 100 13 80 Subnet Mask 256 255 255 0 Default Gateway 02 fes lo IPServer IP Address Ex 220 135 169 136 220 135 169 136 Transmit IP Address to PServer Enable Disable DHCP Client Enable Disable BEEPER Enable Disable ue Cookie Base64 Cookie Release Version V1 10 2008 01 15 IP Server Register 9212Delux in our IP Server then user can easily get online IP address by Name search Please refer page16 for this function 19 VER X X Http Command Verification setup the control possibility from HTTP command or SDK VB amp VC 1 Select Cookie Base64 enable Http command amp SDK control 2 Select Cookie disable Http command amp SDK control 2 1 IP address Settings Ethernet LAN and Internet WAN 2 1 1 Local Area Network LAN In LAN you can set a fixed IP address or gain it from a DHCP server automatically We suggest to use a fixed IP address in order to let the other computers can visit the 9212 Delux Now type the new IP address in the address field of IE you can visit the 9212 Delux You also can use the ipedit exe to find the IP Power 9212 and modify its IP address 2 1 2 Works on Internet WAN User can set the IP provided by your ISP If the 9212 Delux has a public IP address you can control it through the Internet 9212 Delux supports fixed IP DHCP IP Address please type in the IP ad
2. IPOZS5SFIW BIN Tex E IPO258U poate param PAR AP E ES 1 EE Step 2 Open amend web page I O control html file 1 0 Control Th 10 Control Microsoft Internet Explorer u XE BAD emo af EAD ta x Z fo Ome oir meee Power Control Timer Ro RB C Document and Settings dmiisteue PAR E Sud Toe pme cie ann hai HG 32 OF ah Powerl On Off Uer Pe vec O On Off Google v MeienhTe g Rho ee em Power On Off TOLPE see On off Pese Contre Timer Power3 On Off TSLPE sec O On Off somal l ou ose a aa e Power O On OF TOL Sak Og C of pu E ala a CH USL pec O On O Off Foward On Off ISLFE Gee O On Of Powerd On Of TELH sac On OF ESA La Step 3 Amend web page by HTML langrage get from right click as in amend web page C AD coar lb mi Fete ped eoecteetos n a eed Fo Deer tol ham r DIERO MbE HEG PRE SAN Win AR ENQD GM Mo DN ae D ua i a a aia FH H E m ETAN A E oh Py E T m 2 7 x PH mencha ken cham yo te iLl s TO Coneralifcicles oie eu Erdy font FACE Roman LEial COLCR YAGQOQEFF STIET 41 I DO ConcEoOls fnmtr hr BID TAS pone gt ZYTIGL BEGIN gt stores MAWE TinConrrol Tiom Apost amp cTiONH rgi iononrEgol rgi Stable PORDPR 1 5 ote ALIGNS cence PILON bidle Pose pal Edo Cenkre ls tes Tos Toe ade LED ser LIGE center z amp d cinput TREE Eidin BA
3. 7 Setting the 9212 Delux through the Internet After you have setting the Ethernet and router you can access the IP Sensor 9212 from the Internet It will bring you all kinds of convenience After assigning them different IP address and mapping to each port of the router you can visit each equipment through the Internet network Air conditioner Washing machine Monitor at the far end If you have mapped one port for example 85 of the public network IP XXX XXX XXX XXX to the P 192 168 0 3 in the Ethernet you can control eSB E HR the 9202E by typing 192 168 0 3 in the address bar of IE browser in any PC connected to the Internet network You can control the 9202E by typing 192 168 0 3 in the address bar of IE in any PC in the Ethernet 31 VER X X 8 Associated with other IP network product You can associate the IP Power 9212 with other IP network product of OUR in your home Ethernet such as IP Kamera 9000 network camera IP Video 9100 network video server and IP Sensor 9201 IP POWER 9202 Output E to monitor the equipments or sensors Installed in the doors or windows This is an economic solution to achieve the network monitor detection and control Light Detector a Detector gt be 93201E Magnetic Reed witch 9100 Glass Eraka In kou e Mi g paa Temperature Detector i Gas Detectar amer io ha Lier beer F X k k L I
4. Like choose DOS to UNIX b d b jer ALIGN center gt UNIX MAC DOS U d TANW in 6 0 gt EET RED DOS MAC M C Hen a IIR DOS UNIX PIED ror p lk wk po ki eee md VALUE P6 1 HSFN ASCII 8 EBCDIC MALUE On TCL Ep tis RE ABE G d ext IDe P61 TI OU we A WOT RTS et e Step 5 After amend the other 9212 web page you plan to amend Please open program Make9212Html in 9212 web page SDK and just press make html patch 38 IP POWER 9212 USER MANUAL fe Make90258Html Step 6 There will be a new file Update 2006 01 11 bin which is the BIN file include the amend web page Please follow 9212 update procedure to update the firmware BIN file Please note the Update procedure must be done in port 80 T II checklog txt Lag Uh email htm binum exe eels HTML Document r SEB tile 1 khim 374 Hetk htm HTML Document HTML Document 2 KB a KB file4k dat Lago firmwareupdate htm DAT fa HTML Document 5 KB E SEE iocontrol htm bak ke P232 58FW bhin BAE fa3 aa A BIN B 4 EB SI SIZEB Lag losin htm a none HTML Document Cex 7 SEE OKB 5 kaka d fini exe LCL EE LL E F a Make9358Html Microsoft SALE 73 pwd hin 1 HTML Document a 2 EB syster htr systern wait hbn _ Update _2006 01 11 bin HTML Document HTML Document BIN fg x 3 EB 2 EB 512 KB file k htm HTML Document 3EB iocontrol htm HTML Document 4
5. Off P58 1 Output 8 Status On http admin 1234567 192 168 1 100 Set cmd CMD Getlo Please refer to the chart provided for more information Input Number Default Status Change Input 1 Wet Status On nput 2 Wet Status On nput 3 Wet Status On nput 4 Wet Status On Input 5 Dry Status Off Input 7 Dry Status On Status Off Input 8 Dry Status On Status Off 0 Status Off amp LED Off 1 Status On amp LED On Input 6 Dry Status On Status Off 36 IP POWER 9212 USER MANUAL 11 Webpage Customization Customer can use our Web page SDK to amend the word and background pictures for your 9212 If not familiar to write webpage please do not do this amendment Important Notice 1 Each file does not over the original file size 1 The character word part does not over the original amount For instance setup it is 5 characters 2 Do not amend the structure of web page can only amend words and background picture 3 Only support HTML langrage to amend the web page otep 1 Open the 9212 Web page SDK file and choose the web page planned to amend For example web page ipcontrol html file checkloz bins cL mL EB email filelk HTML Document HTML Document 5 EB EB filezk file k HTML Document HTML Document 2 EB 3 EB filed tk firme areupdate LAT 8 HTML Document r T EE iacantrol hhmn bak BAE t Se 4 EE 10control THL Documen
6. if no firmware file update Step2 Click update button the following window will pop up Upgrade Firmware Please select a file bin to upgrade a aaa Upgrading firmware may take 60 seconds Upgrade must NOT be interrupted Step3 Click the Brower button to find the corresponding update file you can download it from our web site or ask it from the dealer then click Update button to start update firmware When the update is finished you must wait one minute before you restart the IP Power NOTICE Due to network transfer unstable to update the firmware BIN file please arrange in Ethernet Local LAN Please check with your reseller distributor importer for the update news If update fail please refer chapter 11 Webpage Customization Step 4 after finish update please waits some second and then re log in 3 kit DOE ep rede Lei Hieroor EXIT iy Sy BPs IRI Q i x QO xiz fs Pm B kip 1523 0 LOVE ap prd e ta E http 192 168 0 100 Eg10p zrade tei Micros TEE HHE RO Amen LE O hlape AE D dE Mtp 192 168 0 100Aei upgrade tei Please wating a minute and click button t next stap 3 Please wating a minute and click button to next step Re Login PS If use DHCP please enable DHCP Note 1 ff the Portis 80 then you can directly update 2 If update fail you can manual reset the device and update again 390 IP POWER 9212 USER MANUAL
7. AJ 2005 AK AP and VILELAAP i HOTE When you Install IP Farm vid 1070 in Ihe first click fhe install lek then choice open Me You will ever ine install inberfaca DOWNLOAD CI co video 9310 AV Player install Program Play me 9310 record AV files a 7 a pm ET r pi Version 1 21 NOTE When you Install F Vides B370 AW Player im T firs CCE fr install link then choice open Be You will ener the install interfaaon 3 Please follow the installation wizard and install all the recommended programs 4 After installation is complete a shortcut of IPEDIT amp INFINITY Cam will be created on the Desktop and in program list of start of your computer NOTE For NEW function TO Record in WMV format install IP KamVid 1070 13 VER X X 5 Initialization 1 Initial Ethernet setup IPEDIT 1 Click ipEdit exe Please check the 9212A SL for power and Ethernet connection Td on M ApEdit A LOCAL Devices area IPEDIT will search for all IP Products 9XXX series in the same local Ethernet The default name of the 9212Delux is IP Power 1 Double click the IP address it will highlight the device name and IP information will be displayed to the right of the screen The IP address of 9212Delux should be in the same subnet with your PC subnet mask and default gateway must be the same as 9212Delux also For example the IP address of 9212Delux is 192 168 10 9 so your computer needs to a
8. Output Number Control Status 0 Off Control Status 1 On Output 1 NC Status Relay Closed Status Relay Open Output 2 NC Status Relay Closed Status Relay Open Output 3 N Status Relay Closed Status Relay Open C Output 6 NO Status Relay Open Status Relay Closed Output 7 NO Status Relay Open Status Relay Closed Output 8 NO Status Relay Open Status Relay Closed 0 No change to the relay status 1 The relay status has been changed 35 VER X X 3 Getlo To read Input status Read P5 Input status Note For Input Status Switch Set on Off Wet Switch Set on On z Dry Default Settings when no device attached Wet Contact 1 4 LED Off Drv Contact 5 8 LED on Command format http admin paswordQ ipaddress Set cmd CMD getio http admin 1234567 192 168 1 100 Set cmd CMD getio Output Message will return P51 0 P52 1 P53 0 P54 1 P55 0 P56 1 P57 0 P58 1 What this means is P5 Represents that this input message is from 9201 Input Module The P51 corresponds to the output port number P51 Input Module Port 1 P52 Input Module Port 2 and so on The 0 1 after each Output Represents whether there has been a status change or not 0 Keep Current Status 1 Change Current Status So for our current output message P51 0 P52 1P53 0 P54 1P55 0 P56 0 P57 0 P58 1HTTP 1 0 200 OK Connection close P52 1 Output 2 Status On P57 0 Output 7 Status
9. the chart provided for more information Output Number Output Status 0 Output Status 1 Output 1 NC Status Closed Status Open Output 7 N Status Open Status Closed Output 8 NO Status Open Status Closed NO Relay Normally Open NC Relay Normally Closed 24 IP POWER 9212 USER MANUAL Example 1 Place command http admin 1234567 192 168 1 100 Set cmd CMD setpower return message as follow P61 0 P62 0 P63 0 P64 0 P65 0 P66 0 P67 0 P68 0 HTTP 1 0 200 OK Connection close GetPower To read Output status read parameter as follow Command format http admin password ipaddress Set cmd CMD getpower http admin 1234567 192 168 1 100 Set cmd CMD setpower Output message will return the follow P61 0 P62 1 P63 0 P64 0 P65 0 P66 0 P67 0 P68 1 HTTP 1 0 200 OK Connection close What this means is P6 Represents that this output message is from 9202 Output Module The P61 corresponds to the output port number P61 Output Module Port 1 P62 Output Module Port 2 and so on The 0 1 after each Output Represents whether there has been a status change or not 0 Keep Current Status 1 Change Current Status So for our current output message P61 0 P62 1 P63 0 P64 0 P65 0 P66 0 P67 0 P68 1 HTTP 1 0 200 OK Connection close P61 0 Output 1 Off P62 1 Output 2 On P68 1 Output 8 Not Connected Output Status Relay Open Please refer to the chart provided for more information
10. 0 Sec On Of OUT4 NC TS m tin eo OUTS5 NO O On OF 0 See On Of OUT6 NO On Of 0 Sec On OF OUT7 NO On Of 0 Sec On Of OUTS NO On O 0 Sec On OF 18 IP POWER 9212 USER MANUAL 1 Control Set the output s state to ON OFF Select the output you want to change and set it to ON or OFF state then click the apply button 2 Timer Use the timer to set off or on the output after a specific amount of time Once you hit the apply button the timer starts counting down Example shows in the figure above means the OUT3 will be in ON state when it starts and will changes the state to OFF after 30 seconds 3 Reset the ON OFF settings Click the reset button you can cancel the previously output settings System configuration Setting the IP address for IP Power 9212Delux Click the Setup button on the left side under system Fill in the proper IP address Subnet Mask Default Gateway and DNS If you choose to use DHCP please make sure that your network supports DHCP service so the IP Power 9212 will automatically find an IP address when it starts You can also control the Beeper sound in system configuration system Configuration ALLCHANGED MUST BE RESTART TO TAKE EFFECT
11. EB IP9258 Update param PARAM fase 1 KB left htm HTML Document 3 EB 7 networkwakeup htmn HTML Document 2 EB setupric htm powerschedule htm HTML Document 5EB HTML Document 12 EB waitupdate htm HTML Document a KB Note program Make9212Html exe and amend web page must in same file If update fail and can not get IP address by IP EDIT please use RS232 jack DB 9 Cable connect with the PC and 9212 and you can get IP address to log in and update again Please refer follow step 1 POWER OFF the 9212 2 Use DB9 cable connect to the COMI1 of PC and the RS232 of 9212 3 Execute WIN program Hyper Terminal please go to Start program Accessories gt Communications gt Hyper Terminal 39 VER X X e Accessibility FA HyperTerminal M un Communications 8b HyperTerminal FR Entertainment Network Connections Connects to other computers Internet telnet sites board systems online services and host computer either a modem or a null madem cable Te Network Setup Wizard E Mew Connection Wize xd Remote Desktop Connection Set the Bits per second as 19200 at COM1 Must at COM1 COMT Properties Port Settings Bits per second i 9700 Data bits H a Parity Hane Stop bits 1 v Flow control Hardware v Restore Defaults 4 Then power ON 9212 you will get message in Hyper Terminal 5 Please check the m
12. IP Power 9212 Delux User Manual IP POWER 9212 USER MANUAL USER MANUAL IP POWER 9212Delux Version V1 00 2006 12 1 VER X X Warning Any changes made to this equipment without permission may cause damages to the device IMPORTANT NOTICE 1 IP POWER 9212 Delux was designed for indoor use we carry no responsibility for possible damages caused by outdoor use especially in the rain 2 Please use the power adapter provided by the dealer we carry no responsibility for the possible damage from using power adapters not 4 Do not shake the IP POWER 9212 Delux in any fashion 5 Please contact the dealer If IP POWER 9212 Delux is not working properly Copyright 2006 All rights reserved No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without the prior written consent of us All trademarks and products mentioned in this document are the properties of us IP POWER 9212 USER MANUAL Table of Content 1 INTRODUCTION enter tte du ebae aa po kep ka desde ke ee D a taye 4 FEATURE Si eos atten a kt AET eme ES n e T 2 BEFORE YOU START inner entente a ka ke n a ki a we 5 PACKAGE CONTENTS cccccccccccucccccceccccevcscccsccustcecccavsesucveccsucececsacsacuevessccscecsuseseceacdeveesresveceese MINIMUM SYSTEM REQUIREMENTS c cscccsccecccsccsecccccsccesecsccesccasscacccsecasstsetees
13. IP Server The default IP server IP Address is provided but the user can also setup his her own IPServer system and use that address as well avslem Configuration IPServer IP Address Ex 220 135 169 136 Transmit IP Address to PServer 9 Enable Disable 16 IP POWER 9212 USER MANUAL 6 Control and settings through the Internet Double click the IP address in IPEDIT and you can enter the login web page Input the default password 12345678 you can change the password after log in click the OK and then you can enter the Web Control page Username admin Password 12345678 IP9212 Delux IP9212 Delux Login GPIO Please enter user name and password Sat Ti Read Lit User Name admin System Setup Advance Setup DpDNS ned Change Password Power Schedule Power Schedule Network Wakeup Password seseses Firmware Update Sensor of IP Power 9212 Read IO Source mode Voltage input IN1 IN4 contacts are active signal sensors If the voltage difference between the two contacts in one set within OV 3V 9212 shows ON It the voltage difference within 4V 24V 9212 shows OFF So user can detect the change of equipment Such as smoke detector light detector and gas detector Sink mode Resistance Input IN5 IN8 contacts are short circuit sensors If the resistance between the two contacts in one set within 00 2000 9212 shows ON If the resistance within 5000 9212 shows OFF So user
14. Input is very little 24529 VER X X 10 Control and Settings Through HTTP Command Note IP Power 9202 Output Pro has predefined Relay Statuses Outputs 1 4 Normal Closed Relay NC Outputs 5 8 Normal Open Relay NO The relay status of the outputs cannot be changed Meaning that Output 1 4 will always be Normally closed and Outputs 5 8 will always be Normally Open Users can control the 9212 s action directly though the HTTP orders The syntax of the HTTP commands are listed below Command format http adminlogin password ipaddress Set cmd CMD CmdType Http Function of 9212 1 SetPower to control I O Command format http adminlogin password ipaddress Set cmd CMD setpower message as follow Output Message will look something like the string of characters below P61 0 P62 1 P63 0 P64 0 P65 0 P66 0 P67 0 P68 1 HTTP 1 0 200 OK Connection close What this means is P6 Represents that this output message is from 9202 Output Module The P61 corresponds to the output port number P61 Output Module Port 1 P62 Output Module Port 2 and so on The 0 1 after each Output Represents whether there has been a status change or not O Keep Current Status 1 Change Current Status So for our current output message P61 0 P62 1 P63 0 P64 0 P65 0 P66 0 P67 0 P68 1 HT TP 1 0 200 OK Connection close P62 1 Output 2 Relay status Closed P68 1 Output 8 Relay status Open Please refer to
15. NEs PinMa VALDE p Of ian fed Etre input Treg radio MARNE FeO VALUE Oge TGI PSO OR gt Ou lt input TTFE radio MARE P6C VALE itd iinput HAHr np n TIMER TYE pese iDbe PED TIRER Vel TT Pao TiNER Sith s SAixLENCTHST zer ALTO inter ale t xtinpur TTPE hidden MARR Pinko VALVE Pel Powecd lt td gt ZEd za4npmE YPE tadic WARE PE VaLiE Cat TEE f l DH On irput Tf3Es5 rumiag HSE TPALE aire scdreanpur EAHE P l TIRER TYPES TENT Ip F i TIMER ALES TOL F6i TEIMER EIIE E MAZLENGTH E str Lpi center zEdrrcinguL MEA bidden DhmEs PicHa VALUEStPA 29s Powers fad quba inpar TTPET EWdlo CNE PRE VALUE Om TOI P ON gt On lt input Tift rasdio MARE TP6Z WALES gede anpe BANK P Z TINIP TPES cert IDeTp52 TIMERT Uiy uEsCn T I POZ TERRE EIIEs E BAIXLENCTHsT che ALIGMe Pehter s ET sede ip TTPE hidden MAZE PinMo VALUET PE l Puwer4dcrrd tEd 4input Trpia cadio RANIS ESSY VALUES CE TGI Pas DH On inpur TTPEst radia BANEsTPAX3 UALIFES casper MARES Pe TIMER TFE exc Ip92 Po3 TEMER UARLUE TJI Pad TINER SIZE 5 EKSLENOTH CET ALTER Genser gt gedh tinpe Than hidiga FHiSke Bubtanklaeng VALUES bpp Lyte eds sra COLSFAN I inpurt ONCEICE CheokzZumnit pply thiis form TYRE button VALUE kpply HLHZ hpplz 4TTGCI ENDI TEE irr LLHUDAGE IavASPEipr TYPE P rexr TINveASCrTIBL Step 4 Save file format as UNIX
16. WER jack 1 Connect the 9200 to HUB through RJ 45 netting cable 2 Connect the 9200 IN BLACK to 9201 BLACK port a 9200 OUT BLUE to 9202 Output BLUE through D SUB cable 3 Connect the HUB to the Internet May through ADSL XDSL modem 4 Connect the power adapter to the 9200 Power on your computer and power adapter of IP POWER 9212 IP POWER 9212 USER MANUAL 9201Pro Hardware connection recommend 4 1 Dry amp Wet Setting In the 9212Delux the DRY or WET contact of each input in 9201 can be selected To setup the Dry or Wet contact of each input signal please open 9201 Input case and adjust the right blue switch only The left switch was developed for further device enhancement and all signals must be kept on ON ki al Leave all Sad nh switches on the ai A LI EU L1 left side on ON yu JC X m La du d un Sea Pli fi P a 4 r da kask TWA ais LEFI SIDE BLUE SWITCH There is two blue switches in the 9201 Please arrange or leave all the setups in the Left Switch to ON E VER X X You can setup the Dry Wet contact in the left blue switch Switch Set on Off Wet Switch Set on On Dry Default Settings when no device attached Wet Contact 1 4 LED Off Dry Contact 5 8 LED on TY r A TIT LLL ae Note When a wet contact device is attached to output set to wet the LED will turn off When a dry contact device is attach
17. XXX Yyyyy Or you can use the ipedit exe to login into the virtual IP of IP Power 9212 Delux 20 IP POWER 9212 USER MANUAL Advanced Setup Advance Selup Configuralion Name Password Kamera 9060 snapshot when DI has trigged Enable Disable Kamera 9060 IP Address Manager IP Address l ki l Trap when DI has trigged O Enable Disable Send e mail when DI has trigged j lO Enable Disable IP Family 92series IP Address Name admin Password sense Auto Search MAC Address Manual Family 92series controlled when DI has trigged Enable Disable Dynamic Static Setting IN 1 8 To use the internal control function which we are going to introduce in following page please set all the pin on left switch to OFF and the light on DI will be all off Please check the light status on DI board for the function it supports We call light turn ON in DI board as LO and light turn off in DI board as LF uw PULL EO 2 As LO in either one each channel 9212 Delux will ask the setting IP 9060A take pictures You can also use the P5 area bottom of 9201 Input of 9212Delux to control the LO 21 VER X X IP Kamera 9060 IP Address faz ho ja IP Kamera 3060 snapshot when P has trigged O Enable 9 puniti When the function is enabled as the DI status changes 9212A will access the 9060 IP camera to take pictures You can also
18. ad properly and you see a error message which states Cookie time out Please delete your temporary internet files and cookies To do this go to IE Tools gt Internet Options please click Delete Cookies and Delete files in Temporary Internet file Temporary Internet files Pages vou view on the Intemet are stored in a special folder for quick viewing later 1 IPEdit Intemet online devices IP Server 220 135 169 138 220 135 168 126 i poco Mppiccomes Device Name eat it Search Connected tazzl 135 1 53 135 Device Mame Mac Address Pot IP Address A 90604 cathy123 OOSUB0000FS6 a 192 165 100 6 060 Cat456 009965665533 ol 220 1 3 33 134 By setting the server address in IP server of advanced setup page the user can easily search for his her IP Power 9212Delux on internet just by searching for the name of the device The default IP address of IP server is 220 135 169 136 Step1 Click the green connect button Step2 In the device name section Type in the name of your device Min of 3 letters IP Server IP Server gives the user the ability to easily search for the name of the device other than searching for a long IP number This flexibility allows the user to easily just remember the name of their device so they can access it with ease To Enable IP Server Go to Setup on the Left hand side of the Webpage and then make sure you have enabled Transmit IP Address to
19. al and Dynamic IP 5 Supports RS232 to control 6 Security code identification and Hardware reset functions 7 Individual LED indicates switch working status 8 Safe durable non electric leakage and anti flammable design 9 Polar protection will even connect contrary port 10 Digital inputs provide de bouncing function 11 Update firmware by the TCP IP network 12 Embedded WATCH DOG 15 Support SMTP Send IP address as log in and send e mail as detecting sensor trigger 16 Auto Internal Control DI Control DO Own or other 9212Delux 17 Time Scheduler pre set the time schedule to turn power on off thru Internet Ethernet 18 Support NTP Network Time Protocol synchronize the time of 9258 to the Internet web 19 WAP Mobile Phone Control can use the GPRS cell phone via WAP to control 20 Setup up own outlet default set DO status as regain power 21 Provide SDK VB amp VC for own Software develop and application 22 Supply Exclusive IP Service for easily location of device on Internet by name Specification 1 DC 5V AC90 240 input 2 D SUB In amp out port 3 RJ45 IP POWER 9212 USER MANUAL Application field can be used with any kind of electrical equipments no matter household appliances or security equipments It can manage the power supply through the web page make it safer for the security equipment and more convenient for digital control at the far end Industrial application field Bank financia
20. ay NC Outputs 5 8 Normal Open Relay NO The relay status of the outputs cannot be changed Meaning that Output 1 4 will always be Normally closed and Outputs 5 8 will always be Normally Open Maximum Rated Voltage 240V AC 60V DC Maximum Rated Currency 12A AC DC Maximum rated voltage for Single relay 24V 10A 120V 10A 250 7A Maximum Switch time Max 10ms Environment Temperature 30 C 55 C NOTICE Only the professionals should operate the following operations in this section and the common user DO NOT try it For an example using a Light bulb 1 Use the electrical wire of the equipment Step 1 Cut off the live wire Use a test pencil or screwdriver with voltage tester to identify the live wire between the two wires of electrical wire 9 NOTE For this method you must cut off the electrical wire of the household appliance Please make the decision after reading method 5 2 and 5 3 11 VER X X Step 2 Use a test pencil or screwdriver with voltage tester to identify the live wire between the two wires of electrical wire Cut off the live wire and connect to the port of IP Power 9212 Use the test pencil or screwdriver with voltage tester again to make sure the connection is correct NOTICE BE CAREFUL IN THIS OPERATION AND DO NOT TOUCH THE WIRE UNDER VOLTAGE WITH ANY PART OF YOUR BODY ESPECIALLY WITH YOUR HANDS 2 Use additional electrical wire you can buy some electrical wire and outlet in
21. can detect the movement of equipment through the magnetic reed switch or other kind of reactive sensors NOTE 1 The data in this figure is the average measure value To ensure the correct detection we suggest user set the voltage lower than 2000 when it shows ON and higher than 500O when it shows OFF 17 VER X X 2 When measuring the resistance of wet contacts the maximum voltage is 5V and the maximum currency is no more than 10mA 1 0 Read D 1 ON 2 ON 5 ON 4 IN 5 IN 6 IN 7 IN 8 P9212 Delux of Of of lof of Of of Of omo set LO Click the refresh button and you will see the similar figure like this It represents the state of the four sets of input signals there may be some delay it up to your network Control of IP Power 9212 SET IO IP Power 9212 now can control 8 outputs at the same time Out1 Out4 are normally closed switches When it is on the corresponding LED lights up the circuit between the two connects is turn off When it is off the corresponding LED light off the circuit between the two connects is turn on Out5 Out8 are normally open switches When it is on the corresponding LED lights up the circuit between the two connects is turn on When it is off the corresponding LED light off the circuit between the two connects is turn off 1 0 Control PIN rO Control Timer OUTI NC On O 0 Sec On OF OUT2 NC O On oflo Sec On Of OUT3 NC On OF 3
22. dd an IP address looks like 192 168 10 XXX to get connection to 9212Delux 2 User can change the device name please use numbers or letter or IP please set in the same subnet as your PC in the text window to the right Then click Submit after setting finish After about 20 seconds the new setting will work Click Update the new setting of equipment will display in text window 3 You can also click REF in IPEDIT to check your PC to get the subnet information And directly press APPLY to update the new IP settings of selected 9212A SL Local Devices 192 168 100 54 IF POWER 192 168 100 198 Mame Cam location Gateway 198 168 0 254 IPAddess 192 168 0 100 REF Setting Netmask 285 255 255 0 Name HTTP Pati 8n Cam location 190 168 0 100 away Cam location 132 168 100 171 HTTP Pota D MAC mann IP Address d T bi a PPPoE ADSL C DHCP Static Netmask Q Rescan By Submit t Reset BE APPLY F1 Help Exit 14 IP POWER 9212 USER MANUAL NOTICE 1 Make sure the power and Ethernet connection of the 9212 are connect properly 2 It can automatically obtain the virtual IP address after you run the ipeditv3 exe but only if your Ethernet supports DHCP Click the IP address to enter the web page If your Ethernet does not support DHCP IP92XX you will change its IP address to fixed IP address Please follow the steps below to change
23. dress provided by your ISP If IP Power 9212 Deluxe is working with a Router please refer to the network settings of the Router Subnet Mask please type in the Subnet Mask provided by your ISP If IP Power 9212 Delux is working with a Router please refer to the network settings of the Router Default gateway please type in the Default Gateway provided by your ISP If IP Power 9212 Delux is working with a Router please refer to the network settings of the Router DNS Server please fill in the IP address of DNS server If you are in Taiwan you can set it to 168 95 1 1 DHCP Clients Enable activate DHCP service DHCP will assign IP address for each PC Disable shut down the DHCP service You can set the IP address by yourself Beeper Enable activate the beeper Disable turn off the beeper If you control the IP Power 9212 Delux through the web page the beeper will beep once when the operation work Note 1 IP address format is XXX XXX XXX XXX yyyyy yyyyy represents the port number which ranges from 1 to 32767 2 Subnet Mask from 0 to 254 XXX XXX XXX O XXX XXX XXX 204 3 If DHCP is disabled user must set the TCP Port and default Gateway If DHCP is enabled then the TCP port will be preset to 80 xxx xxx xxx xxx 80 and the The DHCP server will set default gateway too 4 If the TCP port you set is not 80 your should type in the whole IP address and port in IE or Netscape such as http XXX XXX XXX
24. ed to output set to dry the LED will turn on 4 2 Connection Illustration For different request of normal state of electric equipment 9201 Input offers four sets of voltage signal IN1 IN4 and four sets of shortcut circuit signals IN5 IN3 9201 Input Pro provide 4 set Source mode Voltage Input Out 1 Out 4 ON 4V 24V OFF OV 3V 4 set Sink mode Resistance input Out 5 Out 8 ON 200 ohm 0 ohm OFF 500 ohm IP POWER 9212 USER MANUAL 1 The polarity Right Positive amp Left Negative Left Negative Right Positive NOTE The polarity protective function will protect your device if you reverse the polarity during installation But your device will not work correctly if the polarity is incorrect 2 Source mode Voltage signal INT amp INA can be connected to voltage signal detectors such as smoke detector light detector and gas detector 3 Sink mode Resistance signal IN5 amp IN8 can be connected to magnetic reed switch as the follow figures E I 9 VER X X It can be installed in the entrance guard or security equipment such as doors windows drawers and safe case Derectors mon Source mode Voltage input IN1 IN4 contacts are active signal sensor If the voltage difference between the two contacts in one set within OV 3V 9212 shows ON It the voltage difference within 4V 24V 9212 shows OFF So user can detect the change of equipment Suc
25. elux is a Network Controller amp Sensor with 8 DI amp 8 DO No specific PC or software is needed to use the device You can easily control devices remotely and check their status via the Internet from anywhere in the world Using a Browser such as Internet Explore or Netscape you can securely access the unit It includes 8 Digital Inputs Dry Wet contact which can be switched 8 Digital Relay Outputs that works like an IO Server You can integrate it for Home Office security Personal entertainment and Industrial field applications The API program is supported to help the integrator to easily program any software to integrate it with existing application systems in local computers The IP POWER 9212 can be flexibly applied to Home entertainment amp industry security amp systems with integrated management Feature 1 Embedded web server So the device does not need to be connected to a PC Uses Ethernet or Internet LAN WAN 2 Accessible with popular web browsers IE Internet Explore or Netscape DO NOT need specific Software 3 Comes with 8DI amp 8DO Directly control relay output DO and detects digital input DI 8 Set Sensor Default 4 Set Source mode Dry Voltage Input and amp 4 Set Sink mode Wet Resistance Input Source amp Sink mode can be switched 8 Set Controllers Default 4 Set NO Normal Open amp 4 Sets NC Normal Close 4 Network protocols supported HTTP DDNS DHCP Virtu
26. essage and get your IP address 40 IP POWER 9212 USER MANUAL DHCP Not Enable contig g gateway ip cH at 64 1 dhcp client not enable stow P 192 168 100 104 Jua dar T LOC 188 184 oH confi gateway 192 168 188 1 config dnsserver 168 95 1 HY IP 192 168 100 104 MY MAC H 92 55 8080 01 c3 F 33 WebControl SDK V1 38 wapLogin imeout IP 8 80 80 8 153 astestlpIime 28006 0 17 08 423 27 SustemlpI1me 28006 02 17 11 26 59 6 Usethis IP address to update again We supply original firmware V1 22 for update f 7 Login this address to update again 8 If still cannot finish update successful please check if create BIN file too big If need to ship BIN file please use bin file V1 22 bin in SDK to update back to factory version 41 VER X X
27. h as smoke detector light detector and gas detector NOTE 1 The data in this figure is the average measure value To ensure the correct detection we suggest user set the voltage lower than 3V when it shows OFF and higher than 4V when it shows ON 2 The maximum measure voltage is 24V ON OFF 0 0 5 1 1522 53 154 455 V Slink mode Resistance Input IN5 IN8 contacts are short circuit sensors If the resistance between the two contacts in one set within 00 2000 9212 shows ON If the resistance within 500Q 9212 shows OFF So the users can detect the movement of equipment through the magnetic reed switch or other kind of reactive sensors NOTE 1 The data in this figure is the average measure value To ensure the correct detection we suggest the user set the voltage IP POWER 9212 USER MANUAL lower than 200Q when it shows ON and higher than 5000 when it shows OFF 2 When measuring the resistance of web contacts the maximum voltage is 5V and the maximum currency is no more than 10mA PS magnetic reed switch using the magnetic field of the magnet to produce a signal when there is a movement happened in switch Low cost and easy to use is the chief characteristic of magnetic reed switch Most of them are used in security equipment living product and automatic mechanism 9202 Output Pro Hardware connection recommend IP Power 9202 Output Pro has predefined Relay Statuses Outputs 1 4 Normal Closed Rel
28. in the time in the power control column and choose on or off Support parameter to operate scheduler Disable Just Once every day Work Day every Monday to Friday Weekend every Saturday and Sunday 27 VER X X Internal Clock Settings amp Network Time Protocol NTP User can enter the internal clock settings year month day hour minutes and second NTP function customer can synchronize the time of 9212 to the Internet web address time Selup Dalelime DateTime Grayy mm dd HEMMESS 2006 lw Le j de a NTP Server IP Address he le lem he Piasek Please refer following the NTP server IP address 131 246 9 116 139 18 25 34 128 176 191 9 Note To work NTP please do set up in e mail and have to receive e mail from 9212 Network wakeup Remote Wake up PC by MAC address in Ethernet LAN Use Network port RJ45 you can wake PC on WAN by PC s MAC address Wake On LAN WOL premise 1 The main board needs to support WOL function There must be a port to connect to your network card If your Main board supports WOL you can enable this function in BIOS setting you could find this function in Power Management of BIOS setting 2 Your network card must support WOL remember to connect your connect cable to Main board or the network card can not send power on message to your main board After setup in main board and network card you can use WOL function by following
29. l security system jewels casino cash register in supermarket park traffic control military equipment and airport 2 Before you start 9212 package contents B One set of IP POWER 9212 One set includes 3 separate units 9200 Network Module Base 9201 Input Input Sensor Module 9202 Output Control Module One network wire with RJ45 port One 1A 110 220V adaptor TWO D Sub 15 Pin cable One install CD One rapid install manual Minimum System Requirements Minimum Intel Pentium Il 300MHz compatible AMD processor WINDOWS operating system IE5 0 SP1 Minimum 64MB RAM VGA Card with capability of displaying full Colors and DirectDraw support Network card with RJ45 port Ethernet Hub Router Internet network Ethernet xDSL or other ways depends on whether you need far end control ability or not 5 VER X X 3 Interface Description IP Power 9212 has three units 9200 is the network module base the picture below shows the three units of the IP Power 9212 9201 Input is the input sensor module and 9202 Output is the output control module 4 Hardware amp Software installation Before you star using the IP Power 9212 please follow the steps below B Check the package to make sure the contents are complete B Prepare one Ethernet HUB or Router B Check the voltage of the power supply to make sure it is AC 110 240 volt Hardware Installation Connect RJ45 first before connect PO
30. nfrared Detector EU D g201E Sense Video pM E 5 Lii FR 0 JH Cha ral nk l r A Cameras Come rad Remote Control l m Other 9000 Series e Cont ro l 2 Zim Air Water Other 9000 R rec Condition Rice Heater Washing Series rol TY ai T Machine Heater Ly Z n P X Light 9202E Control 92025 Qut L amernad u PC Remote Control 2 L A f Monitor Screen f EE wu MEN ES an e T pJi EM A mA 4 sg te eee 32 IP POWER 9212 USER MANUAL Q1 forgot the password and can not enter the administration page now what can do A1 Turn on the power normally and then click the ipedit exe program to enter the web page Type in the username super user there is a space between super and user and press ok then press the reset button in 9200 it will back to the default settings Now you can enter the administration page Q2 cannot open the IE web page why A2 Please update your IE or use the up to date version of Netscape browser Q3 Why the on off operation can work immediately A3 if you operate the IP Sensor 9201 Input in Ethernet the operation will work immediately lf you operate it through the Internet the response speed depends on the situation of the network Normally the delay is not obvious because the date need to be transported during operating the IP Sensor 9201
31. ns com then Proxy IP the DNS server you choose will link the domain name of 9212 to its current IP address So the visitor can visit Proxy Port l See the 9212 webpage by input the domain name of 9212 aviosys dnsdojo net In the address column in browser SAVE UPDATE NOW Note When finish setting up the DDNS click SAVE to make sure changes are kept Then press the UPDATE NOW button to send DDNS message package to DDNS Server immediately 1 DDNS IP Please fill in the IP address of DDNS Server and port number 2 Domain Please fill in your total domain name in Your Domain column 3 DDNS user Please fill in the DDNS domain name you applied here 4 DDNS password Fill in the DDNS password which you applying domain process in DDNS Server 5 Enable DDNS You can select true to enable DDNS function or select false to disenable it 6 Proxy server setting Sometimes the message package can not send to DDNS directly you can transmit DDNS message package through proxy server You can use the proxy server by selecting TRUE in Proxy enable column You can find the usable IP address and port of proxy server in some BBS or you can 24 IP POWER 9212 USER MANUAL use some proxy server searching software to search for usable IP address and port of proxy server 7 PROXY IP Please fill in the IP address of proxy server here 8 PROXY PORT Please fill in the proxy port here E Mail setting receive IP addre
32. ower 9212 every time you enter the webpage 6 Subject The subject of the mail to be no more than 50 English letters 7 Mail Body Please type the content of the mail here it cannot be left empty After you have finished all of the above settings click SAVE button to save your settings Setting the password for IP Power 9212 Click the change password option at the left window and you can enter the change password page Follow the instructions fill in the old password and new password then click the apply button to confirm Change Password Old Password Mew Password Confirm Mew Password 26 IP POWER 9212 USER MANUAL Control DI through time schedule User can control the time ON or OFF of the 9212Delux DO through a preset time scheduler Click the power schedule on the left side of the webpage You can select and enter the time schedule settings Click power schedule to control outlet 1 4 PIN 1 0 1 Schedule E J Ei LI PIN rO fi PIN VO Time PARAMETER ON OFF T 05 05 Disable OON OFF Disable OON OFF 2005 05 Disable w OON OFF Disable OON OFF Disable OON OFF Disable OON OFF siis S OON OFF System Startup Power Default Value OUTI NC OUT2 NC OUT3 NC OUT4 NC OON OFF OON OFF O ON OFF OON OFF Submit If user wishes to control the power in one outlet of IP Power 9212 you can fill
33. ss amp inform as Sensor trigger IP Power can setup the e mail address so that the user can receive status changes from the sensors When setting up the receiver e mail address IP Power will send its IP Address to the receiver Selup Email Malserver 123 com Popiserrer labc com UserName 8212delux Password ence sender quest 123 com Recemerl custofzertedc cam Recervrerz Receiveri Subject 19212 Delus Male ody For example Mail Server 123 com Pop3Servcer abc com Password XXXXXXXX Sender guest 123 com Receiver 1 custo ertedc com Subject 9212 Delux 1 Mail Server The server that sends e mails out Please make sure that the server is an available mail server 2 Pop3 Server The server receive IP address in Internet WAN from your ISP for sending Internet IP address by E mail when 9212 in Internet To receive IP address in WAN please fill your ISP e mail receive server In this part please also set the DNS of your ISP in system configuration 3 Password The password of this mailbox is no longer than 8 English characters 4 Sender Please fill in the name of sender The Mail Server must support SMTP and these fields must be entered correctly 95 VER X X 5 Receiver No longer than 50 English letters Please use blank space to separate each receiver s e mail address After you have finished setting up this portion you will receive an email to inform you of the IP address of the IP P
34. ss the button Setting IN 1 8 then you will get following page so you can setup DI and DO settings selling IN 1 8 Configuration an OOOO ou OOOO ow LJEJEJEJEJCJEJES ou LJEJEJEJEJEJEJES ee e ol LI LI In this screen you can select which Inputs activate which Outputs From the picture above when the DI IN7 is detected the DO Out7 will be activated 23 VER X X DDNS Setting cos z A DDNS SETUP DDNS Server Settings when your network connects 3 to the Internet through ADSL your ISP will give you a dynamic IP address This might pose a problem for people who might want to access your 9216 in DDNS SETUP the local network because the IP is always changing This DDNS feature was added to solve this problem DONS Server IP 63 196 95 80 Let s explain that using the DDNS service provided by www dyndns com Your Domain First we apply a domain name for example ippower 9212 DDNS UserName abcdefg in www dyndns com for 9212 set the domain password and select propel DNS server for example D DNS Password eeeeese dnsdojo net for domain name resolve Then input i p the Domain Name Server host name username Enable DDNS TRUE password and etc in the DDNS web page of the 9212 Every time after that the 9212 will start or the user May select select to submit Proxy Enable FALSE 9212 will send a message package including its current IP address domain name to www dynd
35. take pictures Hardware control Set the Input as User can just press the bottom P5 in 9201 Input to change status of any DI and the IP address of 9212A SL to do SNAP shot 3 As LO in either one each channel 9212Delux will send TRAP message of 9212Delux to IP address in Manager IP address You can use the P5 area bottom of 9201 Input of 9212Delux to control the LO Manager TP Address MEM IE RE foo Trap when P5 has trigged O Enable Disable 4 As LO in either one DI 9212Delux will send E mail to inform the user of any input status changes Send e mail when P5 has trigged e Enable Disable You can use the P5 area bottom of 9201 Input of 9212Delux to control the LO 22 IP POWER 9212 USER MANUAL 5 User can Auto control the DO of 9212Delux by DI status change One DI can control 1 8 DO You can also control other 9212Delux devices and units The P5 area bottom of 9201 Input of 9212Delux can be used to control the LO Dynamic as LO for one time the DO part changes one time e Static as LO for one time the DO keeps changing Note When you enable this function DI controls DO SET I O will be disable n 16 AU 13 E IP Family 92series IP Address Namel Password 00000 Auto Search MAC Address Manual IP Family 92series controlled when DI has trigged Enable Disable 9 Dynamic Static If pre
36. the electrical shop to cooperate with IP Power 9212 avoid cutting off the electrical wire of the equipment and can be used flexible in all kind of electrical equipment NOTICE Use a test pencil or screwdriver with voltage tester to identify the live wire between the two wires of electrical wire and make sure of connecting the live wire to the port of IP Power 9212 3 You an control multi power by use the power extension cord 12 IP POWER 9212 USER MANUAL NOTICE Do not connect too much energy intensive electrical equipment such as air conditioner electrical heater microwave over or over in the same electrical outlet Too much electrical currency may cause fire This product not guaranty the possible damage caused from too much electrical currency Software installation Please follow the steps below to install the software 1 Insertthe RED CD in the package and windows will auto run If not please browse for the Autorun html file in CD 2 Click IP KamVid 1070 in driver of CD and click OPEN top install the driver procedure ERIAN NETWORK SEARCH TOOL S NETWORK Goo SEARCH PRODUCT inem cen won Family Program to search Dynamic IP amp Change Name only MANUAI cm Gad P KamVid 1070 insial Program scandhednslaedlPCams gt SDK Ho rw SE E J RES A irm 1 Pst F al STONE multi imdews for 9060 senes 3100 IFFINITY CAM Own Friendly Sofware Tor BODOSL 9100 9212 a MAN Tihti Mi iJ
37. the subnet of your PC 3 If can not get in the 92XX web page please set the segment of IP 9212Delux to be same as your PC You can get your PC network information IP Addres Subnet Mask and Default Gateway by step start gt execute gt key cmd in dialog gt key ipconfig in MS DOS mode es CAWINDO WSS vstem 2h mi exe Microsoft Windows XP Chas 5 1 2600 CG Copyright 1985 2001 Microsoft Corp Co Documents and Settings sGChiu ipconf ig Windows IP Configuration Gonnection specific DHS Suffix IP Address w u w nu um ew 1922168 2188 91 Subnet Mask aoa n w u w 2455 265 255 4 Default Gateway 192 168 188 254 C Documents and Settings Chiu gt The last digit of IP address can be any number between 1 254 but can not be same as your PC If using in any PC just use HUB and type the 192 168 0 100 in Browser or use pedit exe then you can get in the webpage Note The first 3 segments of IP address of your device needs to be the same as your default gateway For Example The IP address of the Gateway is 192 168 1 100 then the first 3 segments of the IP address of your device will be 192 168 1 123 4 The default username and password of IP Power 9212 are Username admin Password 12345678 If forget the new password Login super user There is a space between super and user Password 1234568 15 VER X X Note If the webpage does not lo
38. two step Step 1 Log in 9212 web page and go to Network Wakeup Step 2 Type in your MAC address then press send the PC will be power ON Nebwork Wake Up Selup MAC COSOBAOOSS IP POWER 9212 USER MANUAL Note 1 If the Network card is not onboard card it needs to connect with your Main board by cable Please refer your network card connection 2 Youcan get your MAC address in PC please refer following pictures Go to Network sign gt Status gt Support gt Details Then the value in Physical Address is the PC MAC address Open Network Connections E a rx 3 37 PM General 3 Internet Protocol TCFAF Address Type Assigned by DIHCP Network Connection Details 192 168 100 50 Add 299 294 1 Network Connection Details Property Value 132 168 100 1 T Physical Address RES 5 Address a 2 Subnet Mask Default Gateway 192 168 100 1 DHCP Server 192 168 100 1 Lease Ubtained 11729 2005 3 34 43 PM ease Fanires TA AAANAA 11 147 AM Firmware update If no firmware to update please do not go to this page 29 VER X X As received new firmware user can gain more functions for IP Power 9212 through firmware update Click the firmware update on the right side of the page the following window will pop up Step1 Click firmware update you will see follow webpage lfndate Comcel Note Do not click update
39. useeesenseseseees S INTERFACE DESCRIPTION e io kk ki n ke a a ak tk ka m a n a n 6 4 HARDWARE 8 SOFTWARE INSTALLATION eere 6 IDV ARE INS TA ATON matant an a ab n af e a tn n a eg ao n an n ke are as eman 9201 INPUT PRO HARDWARE CONNECT RECOMMEND 9202 OUTPUT OUTPUT PROHARDWARE CONNECT IRECOMMEND 54359 bilan xeu t aliu ibas ka a doi a w sat duh SOETIWARBREINSTALIDATION ti ni akt tdt rt aded tay n dedico lante frases esi La dod on cud S gH Br wget 14 BASIC SETTING THROUGH ETHERNET rennen ana nena meram aec nas na iaa RR DR a DR RR RR Ra NOR SETTING OF SOFTWARE SHUT DOWN CONTROLLED PC SERVER 6 SETTING AND CONTROL THROUTH THE INTERNET 17 SYSTEM CONFIGURATION ire yn ad kt a tot atin Aaa ta tata de ADVANCE SE PING cct Ne tt avoy anette a teeta A SPECIAL INTER CONTROL vot jit tat dat eae etus ua duum an kb a de a euo wheeled JD NS SETIBING T D Cer EMO TNAM UE EI LEE CDU ed SMTP FOR E MAIL INFORM IP ADDRESS amp SENSOR TRIGGER CONTROL DI THROUGH TIME SCHEDUEL ene GUEOCKANDNERSEFTTING mido m ank abi SERI Ba Ear e pe Swsvav A a e CDU sve v uam sete na NETWORK WAKE UP uz obese asa rin at a olus e to sa ak ab ev ta ita cera a Dix RE anan M AE Pru FIRMWARE UPDATE SES oi twd ie e ia etat e l n setae Ve dO a Dis 3 VER X X 1 Introduction The IP Power 9212SD