Home

1. application 2. technical data user`s manual 3. installation

image

Contents

1. OILIT 1 pc 3 8 for KSP 201 KSS 201 KSN 201 1 pe 1 for a KSH 20_ A M6 nut standard SW 3 pes for KSH 202 4 pes for KSH 203 KSH 204 M6 nut non st SW 1pc for KSH 204 USER S MANUAL CE Manufacturer NIVELCO Process Control Co 1043 Budapest Dugonics u 11 Phone 36 1 889 0100 Fax 36 1 889 0200 e mail marketing nivelco com http nivelco com 2 4 DIMENSIONS 2 O DQ KRK 512 0 switching unit KSK 201 cable probe M6 6 M6 nut _ 112 BSP PROBE SOCKET PROBE SOCKET PROBE KSH 200 KSP 201 KLN 200 KSS 201 KSN 201 Uninsulated reference probe SEPARATOR KSH 202 KLP 204 KSH 203 KSH 204 3 INSTALLATION KRK 512 0 switching unit can be mounted on DIN EN 60715 rail It is recommended that the KLN 200 type probes are cut to the length required for level detection on site The probes should be screwed into the KSO 200 type sockets ALWAYS REMEMBER TO TIGHTEN THE PROBE WITH AN M6 NuT When using KSH 204 type probe sockets the reference probes should be tightened with special SW hexagonal M6 nuts It is suggested that KLP 204 type PVDF separators suitable up to 130 C be used at every 0 5m for multiple probe devices to keep the probes apart A KSK 201 single probe attached to an insulated cable can be lowered into pits and wells without running the risk of a short circuit When a measurement is needed
2. Thank you for choosing a NIVELCO instrument We are sure that you will be satisfied throughout its use 1 APPLICATION The conductive measuring principle can be applied to liquids with specific conductivity over 10 uS cm The switching unit can sense the resistance between probes Conductivity measurement is suitable only for detecting the presence of liquid at a given level of the tank This level is represented by the length of the probe The level switch consists of a NIVOCONT KRK 512 1 type switching unit and the KLN 2010 type probes selected according to the task Probes are to be connected to the NIVOCONT KSL1 20 type probe socket head that can be screwed into the tank If the material of the tank or its internal insulation is not conductive then a reference probe should be used in addition to the one two three or four probe s if the material of the tank is conductive the tank can be used as a reference probe The conductive switch is suitable for filling emptying control or level limit 2 TECHNICAL DATA 2 1 GENERAL DATA 2 1 1 TECHNICAL DATA OF THE SWITCHING UNIT KRK 512 0 5 VAC lt 0 5mA AC Adjustable 5 kQ 100 KQ 3 nF max 400 ms 5 Adjustable 0 5 10 s 1x SPDT 250 V AC1 24 VDC 16 A AC1 4000 VA AC1 384 W DC 4kV Type Probe voltage Probe current Sensitivity Max cable capacity Response Setting accuracy mech Delay Relay output Switching voltage Switching current Switching power Electrical stren
3. WARRANTY All Nivelco products are warranted free of defects in materials or workmanship for a period of two years from the date of purchase as indicated in the Certificate of Warranty Relative humidity max 85 krk5121a0600h_01 Aug 2006 Nivelco reserves the right to change technical data without notice
4. cator foo een T Red LED Probe sensitivity adjustment Function Delay adjustment Front panel of NIVOCONT KRK 512 5 2 LED INDICATION Green LED is on Red LED is on Red LED is off power supply is on relay is switched on contacts 15 and 18 are closed relay is disconnected contacts 15 and 16 are closed 5 3 SINGLE LEVEL MONITORING LIMIT SWITCHING one level the sensor probe should be connected to both E1 and E2 terminals For High Fail safe mode indication the PUMP switch should be in UP position and for Low level alarm indication in DOWN position Level alarm conditions are indicated in the same way by de energised relay state as when a power cut off occurs If KRK 512 C is monitoring only Un 5 4 LEVEL CONTROL NIVOCONT KRK 512 0 can be used for control of filling or emptying During filling control the PUMP switch should be in position UP and during emptying control in position DOWN That way in case a power supply outage occurs energised relay overfilling or unwanted emptying is prevented FILLING u 6 MAINTENANCE REPAIR The device does not require regular maintenance Repair within and beyond the warranty period is carried out at the Manufacturer s location 7 STORAGE Ambient temperature 25 C 70 C 8
5. gth Mechanical life span 3 x107 switches Electrical life span 0 7x10 switches 24V ACIDC Voltage range allowed nominal voltage 15 10 Power consumption max 2 5 VA W mbient temperature 20 C 55 C Electrical connection max 2 5 mm with insulation 1 5 mm2 class III Ingress protection IP 20 Mechanical connection DIN EN 60715 rail Mass 76g 2 1 2 TECHNICAL DATA OF PROBE SOCKETS Type _ ksk 201 ksP 201 Kss 201 KsN 201 KSH 202 KSH 203 KSH 204 Nr of probes 2probes 3probes 4 probes 1 1 ref 1 ref 1 ref probe probe probe socket Cable Pq 9 M4 nut M20x1 5 gland 9 rubber cap protected cable diameter 6 12 mm connection Socket A44 KO35 material steel stainless steel 1 4571 Housing material temperature pressure protection 2 2 ORDER CODES NIVOCONT KRK 51 2 Power supply Code Paint coated aluminium cast Probes Code 2 nos 2 reference probe 3 nos 3 reference probe 4 nos 4 reference probe Cable probe Single probe PP socket Single probe steel S socket Single probe st steel socket Multiple probes st H steel socket NIVOCONT KLN 2 y Probe length Code 05 30 to be ordered in 0 5 m units NIVOCONT K L P 2 0 4 Separator 2 3 ACCESSORIES NIVOCONT KRK 512 CONDUCTIVE LEVEL SWITCH User s manual Certificate of warranty Declaration of conformity Sealing 2 mm thick KLINGER
6. in a well or in a plastic pipe 2 of them have to be used 4 ELECTRICAL CONNECTION If the wall of the tank is conductive no reference probe is needed In this case terminal C is to be connected to the tank On multiple probe units o o A1 A2 power supply C reference probe E1 upper level probe ee may IE WTS E1 and E2 are marked with E 7 E2 bottom level probe H S shielding 1 4 the reference probe is max 15 16 18 Teley output marked with C Admissible min length of cable between signal processor and probes depends on cable capacity and conductivity To eliminate signal interference it is recommended to use shielded cable when wiring probes ome Connections for NIVOCONT KRK 512 1 5 PUTTING INTO OPERATION 5 1 ADJUSTMENT The green LED Un shows that the unit is on and the energised state of the relay is indicated by the red LED Operating mode and delay time ON and OFF can be set with the rotary selector switch and potentiometer on the front panel To set the sensitivity using SENS potentiometer do the following submerge all probes into the fluid Set a minimal delay time t Adjust the sensitivity from min to max value until the relay became energised Now set the sensitivity a little higher but don t set a too high sensitivity than needed Power supply terminals Probe connection terminals Power supply indicator Green LED Output indi